The DOI matches its Crossref record; 87 of the 87 references it cites were found in a registry or an index.
Blood-Contacting Biomaterials: In Vitro Evaluation of the Hemocompatibility
Open accessAbstract
Hemocompatibility of blood-contacting biomaterials is one of the most important criteria for their successful in vivo applicability. Thus, extensive in vitro analyses according to ISO 10993-4 are required prior to clinical applications. In this review, we summarize essential aspects regarding the evaluation of the hemocompatibility of biomaterials and the required in vitro analyses for determining the blood compatibility. Static, agitated, or shear flow models are used to perform hemocompatibility studies. Before and after the incubation of the test material with fresh human blood, hemolysis, cell counts, and the activation of platelets, leukocytes, coagulation and complement system are analyzed. Furthermore, the surface of biomaterials are evaluated concerning attachment of blood cells, adsorption of proteins, and generation of thrombus and fibrin networks.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Neutrophil Extracellular Traps Kill Bacteria
Brinkmann, V., Reichard, U., Goosmann, C., Fauler, B., Uhlemann, Y., Weiss, D. S., Weinrauch, Y., & Zychlinsky, A. (2004) · Science · doi:10.1126/science.1092385 · Cited by 10,268
Complement and its role in innate and adaptive immune responses
Dunkelberger, J. R., & Song, W.-C. (2010) · Cell Research · doi:10.1038/cr.2009.139 · Cited by 1,932
Signaling in innate immunity and inflammation
Newton, K., & Dixit, V. M. (2012) · Cold Spring Harbor Perspectives in Biology · doi:10.1101/cshperspect.a006049 · Cited by 1,513 · cited 2×
“Thereby, the following conformational changes on the bloodcontacting surface are considered as initial trigger for the complement activation via the alternative or classical pathway (Gorbet and Sefton, 2004; Andersson et al., 2005; Nilsson et al., 2007).”
BackgroundGorbet, M. B., & Sefton, M. V. (2004) · Biomaterials · doi:10.1016/j.biomaterials.2004.01.023 · Cited by 1,347
Platelet secretion: From haemostasis to wound healing and beyond
Golebiewska, E. M., & Poole, A. W. (2015) · Blood Reviews · doi:10.1016/j.blre.2014.10.003 · Cited by 930
Neutrophil extracellular traps promote deep vein thrombosis in mice
BRILL, A., FUCHS, T. A., SAVCHENKO, A. S., THOMAS, G. M., MARTINOD, K., DE MEYER, S. F., BHANDARI, A. A., & WAGNER, D. D. (2012) · Journal of Thrombosis and Haemostasis · doi:10.1111/j.1538-7836.2011.04544.x · Cited by 897
Platelet Polyphosphates Are Proinflammatory and Procoagulant Mediators In Vivo
Müller, F., Mutch, N. J., Schenk, W. A., Smith, S. A., Esterl, L., Spronk, H. M., Schmidbauer, S., Gahl, W. A., Morrissey, J. H., & Renné, T. (2009) · Cell · doi:10.1016/j.cell.2009.11.001 · Cited by 831
Respiratory burst in human neutrophils
Dahlgren, C., & Karlsson, A. (1999) · Journal of Immunological Methods · doi:10.1016/s0022-1759(99)00146-5 · Cited by 810
Millar, J. E., Fanning, J. P., McDonald, C. I., McAuley, D. F., & Fraser, J. F. (2016) · Critical Care · doi:10.1186/s13054-016-1570-4 · Cited by 794
Interaction of high molecular weight kininogen, factor XII, and fibrinogen in plasma at interfaces
Vroman, L., Adams, A., Fischer, G., & Munoz, P. (1980) · Blood · doi:10.1182/blood.v55.1.156.156 · Cited by 781
Endothelial cell control of thrombosis
Yau, J. W., Teoh, H., & Verma, S. (2015) · BMC Cardiovascular Disorders · doi:10.1186/s12872-015-0124-z · Cited by 691
Neutrophil Extracellular Traps and Its Implications in Inflammation: An Overview
Delgado-Rizo, V., Martínez-Guzmán, M. A., Iñiguez-Gutierrez, L., García-Orozco, A., Alvarado-Navarro, A., & Fafutis-Morris, M. (2017) · Frontiers in Immunology · doi:10.3389/fimmu.2017.00081 · Cited by 686
Neutrophils scan for activated platelets to initiate inflammation
Sreeramkumar, V., Adrover, J. M., Ballesteros, I., Cuartero, M. I., Rossaint, J., Bilbao, I., Nácher, M., Pitaval, C., Radovanovic, I., Fukui, Y., et al. (2014) · Science · doi:10.1126/science.1256478 · Cited by 650
Zhao, Y., Sun, X., Zhang, G., Trewyn, B. G., Slowing, I. I., & Lin, V. S.-Y. (2011) · ACS Nano · doi:10.1021/nn103077k · Cited by 572
Ritis, K., Doumas, M., Mastellos, D., Micheli, A., Giaglis, S., Magotti, P., Rafail, S., Kartalis, G., Sideras, P., & Lambris, J. D. (2006) · The Journal of Immunology · doi:10.4049/jimmunol.177.7.4794 · Cited by 489
Interactions between coagulation and complement—their role in inflammation
Oikonomopoulou, K., Ricklin, D., Ward, P. A., & Lambris, J. D. (2012) · Seminars in Immunopathology · doi:10.1007/s00281-011-0280-x · Cited by 486
Frenette, P. S., Denis, C. V., Weiss, L., Jurk, K., Subbarao, S., Kehrel, B., Hartwig, J. H., Vestweber, D., & Wagner, D. D. (2000) · The Journal of Experimental Medicine · doi:10.1084/jem.191.8.1413 · Cited by 435
The role of complement in biomaterial-induced inflammation
Nilsson, B., Ekdahl, K. N., Mollnes, T. E., & Lambris, J. D. (2007) · Molecular Immunology · doi:10.1016/j.molimm.2006.06.020 · Cited by 431
Methods of endotoxin removal from biological preparations: a review.
Magalhães, P. O., Lopes, A. M., Mazzola, P. G., Rangel‐Yagui, C. D. O., Penna, T. C. V., & Pessoa, A. (2007) · PubMed · Cited by 414
Synthesis and Characterization of Hybrid Hyaluronic Acid-Gelatin Hydrogels
Camci-Unal, G., Cuttica, D., Annabi, N., Demarchi, D., & Khademhosseini, A. (2013) · Biomacromolecules · doi:10.1021/bm3019856 · Cited by 343
Contact system revisited: an interface between inflammation, coagulation, and innate immunity
Long, A. T., Kenne, E., Jung, R., Fuchs, T. A., & Renné, T. (2016) · Journal of Thrombosis and Haemostasis · doi:10.1111/jth.13235 · Cited by 329
Xiao, W., He, J., Nichol, J. W., Wang, L., Hutson, C. B., Wang, B., Du, Y., Fan, H., & Khademhosseini, A. (2011) · Acta Biomaterialia · doi:10.1016/j.actbio.2011.01.016 · Cited by 315
Biró, É., Sturk-Maquelin, K. N., Vogel, G. M. T., Meuleman, D. G., Smit, M. J., Hack, C. E., Sturk, A., & Nieuwland, R. (2003) · Journal of Thrombosis and Haemostasis · doi:10.1046/j.1538-7836.2003.00456.x · Cited by 314
Blood compatible materials: state of the art
Liu, X., Yuan, L., Li, D., Tang, Z., Wang, Y., Chen, G., Chen, H., & Brash, J. L. (2014) · J. Mater. Chem. B · doi:10.1039/c4tb00881b · Cited by 288
C5a Induces Tissue Factor Activity on Endothelial Cells
Ikeda, K., Nagasawa, K., Horiuchi, T., Tsuru, T., Nishizaka, H., & Niho, Y. (1997) · Thrombosis and Haemostasis · doi:10.1055/s-0038-1655974 · Cited by 272
Noubouossie, D. F., Whelihan, M. F., Yu, Y.-B., Sparkenbaugh, E., Pawlinski, R., Monroe, D. M., & Key, N. S. (2017) · Blood · doi:10.1182/blood-2016-06-722298 · Cited by 246
Bradykinin stimulates tumor necrosis factor and interleukin‐1 release from macrophages
Tiffany, C. W., & Burch, R. M. (1989) · FEBS Letters · doi:10.1016/0014-5793(89)81331-6 · Cited by 238
The role of nanoparticle size in hemocompatibility
Mayer, A., Vadon, M., Rinner, B., Novak, A., Wintersteiger, R., & Fröhlich, E. (2009) · Toxicology · doi:10.1016/j.tox.2009.01.015 · Cited by 209
Brandt, E., Petersen, F., Ludwig, A., Ehlert, J. E., Bock, L., & Flad, H.-D. (2000) · Journal of Leukocyte Biology · doi:10.1002/jlb.67.4.471 · Cited by 208
Contact pathway of coagulation and inflammation
Wu, Y. (2015) · Thrombosis Journal · doi:10.1186/s12959-015-0048-y · Cited by 206
Endotoxin Contamination: A Key Element in the Interpretation of Nanosafety Studies
Li, Y., & Boraschi, D. (2016) · Nanomedicine · doi:10.2217/nnm.15.196 · Cited by 196
Andersson, J., Ekdahl, K. N., Lambris, J. D., & Nilsson, B. (2005) · Biomaterials · doi:10.1016/j.biomaterials.2004.05.011 · Cited by 188
Hemolysis and Acute Kidney Failure
Qian, Q., Nath, K. A., Wu, Y., Daoud, T. M., & Sethi, S. (2010) · American Journal of Kidney Diseases · doi:10.1053/j.ajkd.2010.03.025 · Cited by 172
Measurement of whole blood thrombus formation using parallel-plate flow chambers–a practical guide
Van Kruchten, R., Cosemans, J. M. E. M., & Heemskerk, J. W. M. (2012) · Platelets · doi:10.3109/09537104.2011.630848 · Cited by 153
Complement anaphylatoxin C5a contributes to hemodialysis-associated thrombosis
Kourtzelis, I., Markiewski, M. M., Doumas, M. N., Rafail, S., Kambas, K., Mitroulis, I., Panagoutsos, S. A., Passadakis, P., Vargemezis, V., Magotti, P., et al. (2010) · Blood · doi:10.1182/blood-2010-01-264051 · Cited by 137
Krajewski, S., Prucek, R., Panáček, A., Avci‐Adali, M., Nolte, A., Straub, A., Zbořil, R., Wendel, H. P., & Kvı́tek, L. (2013) · Acta Biomaterialia · doi:10.1016/j.actbio.2013.03.016 · Cited by 133
Self-citationNeutrophil elastase in bronchiectasis
Gramegna, A., Amati, F., Terranova, L., Sotgiu, G., Tarsia, P., Miglietta, D., Calderazzo, M. A., Aliberti, S., & Blasi, F. (2017) · Respiratory Research · doi:10.1186/s12931-017-0691-x · Cited by 131
Zhang, L., Casey, B. J., Galanakis, D. K., Marmorat, C., Skoog, S. A., Vorvolakos, K., Simon, M., & Rafailovich, M. H. (2017) · Acta Biomaterialia · doi:10.1016/j.actbio.2017.03.002 · Cited by 128
Haycox, C. L., & Ratner, B. D. (1993) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820270909 · Cited by 125
Action of Nanoparticles on Platelet Activation and Plasmatic Coagulation
Fröhlich, E. (2016) · Current Medicinal Chemistry · doi:10.2174/0929867323666160106151428 · Cited by 123
Anti‐platelet therapy: ADP receptor antagonists
Wijeyeratne, Y. D., & Heptinstall, S. (2011) · British Journal of Clinical Pharmacology · doi:10.1111/j.1365-2125.2011.03999.x · Cited by 120
The effects of PEG-based surface modification of PDMS microchannels on long-term hemocompatibility
Kovach, K. M., Capadona, J. R., Gupta, A. S., & Potkay, J. A. (2014) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.35090 · Cited by 116
Obstacles in Haemocompatibility Testing
van Oeveren, W. (2013) · Scientifica · doi:10.1155/2013/392584 · Cited by 114
Tissue factor is expressed on monocytes during simulated extracorporeal circulation.
Kappelmayer, J., Bernabei, A., Edmunds, L. H., Edgington, T. S., & Colman, R. W. (1993) · Circulation Research · doi:10.1161/01.res.72.5.1075 · Cited by 111
Bae, S. W., Kim, H. S., Nam, Y., Park, Y. S., Jo, S. A., & Jo, I. (2003) · Biochemical and Biophysical Research Communications · doi:10.1016/s0006-291x(03)01086-6 · Cited by 107
Measuring the 50% Haemolytic Complement (CH50) Activity of Serum
Costabile, M. (2010) · Journal of Visualized Experiments · doi:10.3791/1923 · Cited by 101
Roesslein, M., Hirsch, C., Kaiser, J., Krug, H. F., & Wick, P. (2013) · International Journal of Molecular Sciences · doi:10.3390/ijms141224320 · Cited by 99
Mohan, C. C., Chennazhi, K. P., & Menon, D. (2013) · Acta Biomaterialia · doi:10.1016/j.actbio.2013.08.023 · Cited by 91
Maitz, M. F., Sperling, C., Wongpinyochit, T., Herklotz, M., Werner, C., & Seib, F. P. (2017) · Nanomedicine Nanotechnology Biology and Medicine · doi:10.1016/j.nano.2017.07.012 · Cited by 88
Effect of biopassive and bioactive surface‐coatings on the hemocompatibility of membrane oxygenators
Zimmermann, A. K., Weber, N., Aebert, H., Ziemer, G., & Wendel, H. P. (2006) · Journal of Biomedical Materials Research Part B Applied Biomaterials · doi:10.1002/jbm.b.30614 · Cited by 87
Self-citationP-selectin ligation induces platelet activation and enhances microaggregate and thrombus formation
Théorêt, J., Yacoub, D., Hachem, A., Gillis, M., & Merhi, Y. (2011) · Thrombosis Research · doi:10.1016/j.thromres.2011.04.018 · Cited by 86
Watanabe, J., Marathe, G. K., Neilsen, P. O., et al. (2003) · Journal of Biological Chemistry · doi:10.1074/jbc.m305321200 · Cited by 83
Hemocompatibility assessment of poly(2-dimethylamino ethylmethacrylate) (PDMAEMA)-based polymers
Cerda-Cristerna, B. I., Flores, H., Pozos‐Guillén, A., Pérez, E., Sevrin, C., & Grandfils, C. (2011) · Journal of Controlled Release · doi:10.1016/j.jconrel.2011.04.016 · Cited by 77
Sperling, C., Maitz, M. F., Grasso, S., Werner, C., & Kanse, S. M. (2017) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.7b14281 · Cited by 75
Flow cytometric study of in vitro neutrophil activation by biomaterials
Gorbet, M., Yeo, E. L., & Sefton, M. V. (1999) · Journal of Biomedical Materials Research · Cited by 69
Stang, K., Krajewski, S., Neumann, B., Kurz, J., Post, M., Stoppelkamp, S., Fennrich, S., Avci‐Adali, M., Armbruster, D., Schlensak, C., et al. (2014) · Materials Science and Engineering C · doi:10.1016/j.msec.2014.05.070 · Cited by 68
Self-citationAre there sufficient standards for the in vitro hemocompatibility testing of biomaterials?
Braune, S., Grunze, M., Straub, A., & Jung, F. (2013) · Biointerphases · doi:10.1186/1559-4106-8-33 · Cited by 68
van Oeveren, W., Tielliu, I. F. J., & de Hart, J. (2012) · International Journal of Biomaterials · doi:10.1155/2012/673163 · Cited by 67
Platelet Granule Exocytosis: A Comparison with Chromaffin Cells
Fitch, J. L., & Flaumenhaft, R. C. (2013) · Frontiers in Endocrinology · doi:10.3389/fendo.2013.00077 · Cited by 65
Sinn, S., Scheuermann, T., Deichelbohrer, S., Ziemer, G., & Wendel, H. P. (2011) · Journal of Materials Science Materials in Medicine · doi:10.1007/s10856-011-4335-2 · Cited by 65
Self-citationIn vitro hemocompatibility and corrosion behavior of new Zr-binary alloys in whole human blood
Totea, G., Ioniță, D., Demetrescu, I., & Mitache, M. M. (2014) · Open Chemistry · doi:10.2478/s11532-014-0535-1 · Cited by 64
Engberg, A. E., Nilsson, P. H., Huang, S., Fromell, K., Hamad, O. A., Mollnes, T. E., Rosengren-Holmberg, J. P., Sandholm, K., Teramura, Y., Nicholls, I. A., et al. (2014) · Biomaterials · doi:10.1016/j.biomaterials.2014.09.011 · Cited by 64
Basu, A., Hong, J., & Ferraz, N. (2017) · Macromolecular Bioscience · doi:10.1002/mabi.201700236 · Cited by 61
Rupture Forces among Human Blood Platelets at different Degrees of Activation
Nguyen, T.-H., Palankar, R., Bui, V.-C., Medvedev, N., Greinacher, A., & Delcea, M. (2016) · Scientific Reports · doi:10.1038/srep25402 · Cited by 60
Kopp, R., Mottaghy, K., & Kirschfink, M. (2002) · ASAIO Journal · doi:10.1097/00002480-200211000-00005 · Cited by 57
Engberg, A. E., Rosengren-Holmberg, J. P., Chen, H., Nilsson, B., Lambris, J. D., Nicholls, I. A., & Ekdahl, K. N. (2011) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.33030 · Cited by 57
Ballet, T., Boulangé, L., Brechet, Y. J. M., Brückert, F., & Weidenhaupt, M. (2010) · Bulletin of the Polish Academy of Sciences Technical Sciences · doi:10.2478/v10175-010-0028-0 · Cited by 56
In vitro hemocompatibility testing: The importance of fresh blood
Blok, S. L. J., Engels, G. E., & van Oeveren, W. (2016) · Biointerphases · doi:10.1116/1.4941850 · Cited by 55
Monitoring in vitro thrombus formation with novel microfluidic devices
Westein, E., de Witt, S., Lamers, M., Cosemans, J. M. E. M., & Heemskerk, J. W. M. (2012) · Platelets · doi:10.3109/09537104.2012.709653 · Cited by 54
Endotoxin-induced effects on platelets and monocytes in an in vivo model of inflammation
Kälsch, T., Elmas, E., Nguyen, X. D., Suvajac, N., Klüter, H., Borggrefe, M. M., & Dempfle, C. ‐. (2007) · Basic Research in Cardiology · doi:10.1007/s00395-007-0667-y · Cited by 53
Kent, N. J., Basabe‐Desmonts, L., Meade, G., MacCraith, B. D., Corcoran, B., Kenny, D. J., & Ricco, A. J. (2010) · Biomedical Microdevices · doi:10.1007/s10544-010-9453-y · Cited by 53
In vitro blood reactivity to hydroxylated and non-hydroxylated polymer surfaces
Sperling, C., Maitz, M. F., Talkenberger, S., Gouzy, M.-F., Groth, T., & Werner, C. (2007) · Biomaterials · doi:10.1016/j.biomaterials.2007.04.041 · Cited by 53
Use of microfluidics to assess the platelet-based control of coagulation
Nagy, M., Heemskerk, J. W. M., & Swieringa, F. (2017) · Platelets · doi:10.1080/09537104.2017.1293809 · Cited by 49
Wetterö, J., Bengtsson, T., & Tengvall, P. (2000) · Journal of Biomedical Materials Research · Cited by 43
Hemocompatibility and biocompatibility of antibacterial biomimetic hybrid films
Ferrer, M. C. C., Eckmann, U. N., Composto, R. J., & Eckmann, D. M. (2013) · Toxicology and Applied Pharmacology · doi:10.1016/j.taap.2013.07.023 · Cited by 41
Sukavaneshvar, S. (2016) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2016.07.009 · Cited by 40
In microfluidico: Recreating in vivo hemodynamics using miniaturized devices
Zhu, S., Herbig, B. A., Li, R., Colace, T. V., Muthard, R. W., Neeves, K. B., & Diamond, S. L. (2016) · Biorheology · doi:10.3233/bir-15065 · Cited by 37
Punet, X., Mauchauffé, R., Rodríguez‐Cabello, J. C., Alonso, M., Engel, E., & Mateos‐Timoneda, M. A. (2015) · Regenerative Biomaterials · doi:10.1093/rb/rbv014 · Cited by 36
Sinn, S., Müller, L., Drechsel, H., Wandel, M., Northoff, H., Ziemer, G., Wendel, H. P., & Gehring, F. K. (2010) · The Analyst · doi:10.1039/c0an00474j · Cited by 34
Self-citationMcClung, W. G., Babcock, D. E., & Brash, J. L. (2006) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.31018 · Cited by 31
Harnessing the Platelet Signaling Network to Produce an Optimal Hemostatic Response
Brass, L. F., Tomaiuolo, M., & Stalker, T. J. (2013) · Hematology/Oncology Clinics of North America · doi:10.1016/j.hoc.2013.02.002 · Cited by 29
Fatisson, J., Mansouri, S., Yacoub, D., et al. (2011) · Journal of The Royal Society Interface · doi:10.1098/rsif.2010.0617 · Cited by 28
Improved ex vivo blood compatibility of central venous catheter with noble metal alloy coating
Homann, M. V., Johansson, D., Wallén, H., & Sánchez, J. (2015) · Journal of Biomedical Materials Research Part B Applied Biomaterials · doi:10.1002/jbm.b.33403 · Cited by 25
Balasubramanian, V., & Slack, S. M. (2001) · ASAIO Journal · doi:10.1097/00002480-200107000-00012 · Cited by 14
A Two-Step Protocol to Remove Endotoxins from Human-Like Collagen
Zhang, J., Zhu, C., Fan, D., Ma, X., Mi, Y., & Xue, W. (2015) · Separation Science and Technology · doi:10.1080/01496395.2014.978467 · Cited by 9
Ex vivo simulation of cardiopulmonary bypass with human blood for hemocompatibility testing
Teligui, L., Dalmayrac, E., Corbeau, J.-J., Bouquet, E., Godon, A., Denommé‐Pichon, A., Binuani, P., Verron, L., Boer, C., & Baufreton, C. (2015) · Perfusion · doi:10.1177/0267659115599454 · Cited by 8
Cited by
Next-generation tissue-engineered heart valves with repair, remodelling and regeneration capacity
Fioretta, E. S., Motta, S. E., Lintas, V., Loerakker, S., Parker, K. K., Baaijens, F. P. T., Falk, V., Hoerstrup, S. P., & Emmert, M. Y. (2021) · Nature Reviews Cardiology · doi:10.1038/s41569-020-0422-8 · Cited by 262
Hernandez, J. L., & Woodrow, K. A. (2022) · Advanced Healthcare Materials · doi:10.1002/adhm.202102087 · Cited by 259
Biocompatibility assessment of biomaterials used in orthopedic devices: An overview (Review)
Huzum, B., Puha, B., Necoara, R., Gheorghevici, S., Puha, G., Filip, A., Sirbu, P., & Alexa, O. (2021) · Experimental and Therapeutic Medicine · doi:10.3892/etm.2021.10750 · Cited by 253
Nájera-Maldonado, L., Parra-González, M., Peralta-Cuevas, E., Gutierrez-Onofre, A. J., Garcia-Atutxa, I., & Villanueva-Flores, F. (2025) · Pharmaceutics · doi:10.3390/pharmaceutics17091169 · Cited by 40
Design of Nanotechnological Carriers for Ocular Delivery of Mangiferin: Preformulation Study
Santonocito, D., Vivero-Lopez, M., Lauro, M. R., Torrisi, C., Castelli, F., Sarpietro, M. G., & Puglia, C. (2022) · Molecules · doi:10.3390/molecules27041328 · Cited by 32
Metadata
- Authors
- Weber, M., Steinle, H., Golombek, S., Hann, L., Schlensak, C., Wendel, H. P., & Avci-Adali, M.
- Venue
- Frontiers in Bioengineering and Biotechnology
- Publisher
- Frontiers Media SA
- Published
- 2018-07-16
- Volume
- 6
- Pages
- 99-99
- ISSN
- 2296-4185 (ISSN-L)
- OpenAlex
- W2884780408
- Cited by
- 728
- References
- 87
- FWCI
- 14.23
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.