Improving the Generalizability of Convolutional Neural Network-Based Segmentation on CMR Images
Open accessThe DOI matches its Crossref record; 13 of the 13 references it cites were found in a registry or an index.
Abstract
Convolutional neural network (CNN) based segmentation methods provide an efficient and automated way for clinicians to assess the structure and function of the heart in cardiac MR images. While CNNs can generally perform the segmentation tasks with high accuracy when training and test images come from the same domain (e.g. same scanner or site), their performance often degrades dramatically on images from different scanners or clinical sites. We propose a simple yet effective way for improving the network generalization ability by carefully designing data normalization and augmentation strategies to accommodate common scenarios in multi-site, multi-scanner clinical imaging data sets. We demonstrate that a neural network trained on a single-site single-scanner dataset from the UK Biobank can be successfully applied to segmenting cardiac MR images across different sites and different scanners without substantial loss of accuracy. Specifically, the method was trained on a large set of 3,975 subjects from the UK Biobank. It was then directly tested on 600 different subjects from the UK Biobank for intra-domain testing and two other sets for cross-domain testing: the ACDC dataset (100 subjects, 1 site, 2 scanners) and the BSCMR-AS dataset (599 subjects, 6 sites, 9 scanners). The proposed method produces promising segmentation results on the UK Biobank test set which are comparable to previously reported values in the literature, while also performing well on cross-domain test sets, achieving a mean Dice metric of 0.90 for the left ventricle, 0.81 for the myocardium and 0.82 for the right ventricle on the ACDC dataset; and 0.89 for the left ventricle, 0.83 for the myocardium on the BSCMR-AS dataset. The proposed method offers a potential solution to improve CNN-based model generalizability for the cross-scanner and cross-site cardiac MR image segmentation task.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
U-Net: Convolutional Networks for Biomedical Image Segmentation
Ronneberger, O., Fischer, P., & Brox, T. (2015) · Lecture notes in computer science · doi:10.1007/978-3-319-24574-4_28 · Cited by 99,404
Learning Transferable Features with Deep Adaptation Networks
Long, M., Cao, Y., Wang, J., & Jordan, M. I. (2015) · arXiv · doi:10.48550/arxiv.1502.02791 · Cited by 4,505 · cited 1×
“Instead, it only uses either feature-level information [11, 12, 13] or image-”
MethodFry, A., Littlejohns, T. J., Sudlow, C., Doherty, N., Adamska, L., Sprosen, T., Collins, R., & Allen, N. E. (2017) · American Journal of Epidemiology · doi:10.1093/aje/kwx246 · Cited by 3,979 · cited 1×
“amount of subjects with self-reported cardiovascular diseases, and the majority of the data are healthy subjects in middle and later life [22, 37, 3].”
BackgroundDeep CORAL: Correlation Alignment for Deep Domain Adaptation
Sun, B., & Saenko, K. (2016) · Lecture Notes in Computer Science · doi:10.1007/978-3-319-49409-8_35 · Cited by 3,757
CyCADA: Cycle-Consistent Adversarial Domain Adaptation
Hoffman, J., Tzeng, E., Park, T., Zhu, J.-Y., Isola, P., Saenko, K., Efros, A. A., & Darrell, T. (2017) · arXiv · doi:10.48550/arxiv.1711.03213 · Cited by 2,656 · cited 2×
“level information [13] to optimize the network performance on the target domain.”
BackgroundMethodBernard, O., Lalande, A., Zotti, C., Cervenansky, F., Yang, X., Heng, P.-A., Cetin, I., Lekadir, K., Camara, O., Gonzalez Ballester, M. A., et al. (2018) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2018.2837502 · Cited by 2,431 · cited 4×
“The performance of the proposed method was evaluated using the Dice score (3D version) which was also used in the ACDC benchmark study [1] and [3].”
BackgroundMethodInfluentialSelf-citationDeep visual domain adaptation: A survey
Wang, M., & Deng, W. (2018) · Neurocomputing · doi:10.1016/j.neucom.2018.05.083 · Cited by 2,209
Rotation-invariant convolutional neural networks for galaxy morphology prediction
Dieleman, S., Willett, K. W., & Dambre, J. (2015) · Monthly Notices of the Royal Astronomical Society · doi:10.1093/mnras/stv632 · Cited by 781
Automated cardiovascular magnetic resonance image analysis with fully convolutional networks
Bai, W., Sinclair, M., Tarroni, G., Oktay, O., Rajchl, M., Vaillant, G., Lee, A. M., Aung, N., Lukaschuk, E., Sanghvi, M. M., et al. (2018) · Journal of Cardiovascular Magnetic Resonance · doi:10.1186/s12968-018-0471-x · Cited by 773 · cited 10×
“segmentation tasks on a specific dataset [16, 1, 15, 3].”
BackgroundMethodResultInfluentialSelf-citationAdaptive batch normalization for practical domain adaptation
Li, Y., Wang, N., Shi, J., Hou, X., & Liu, J. (2018) · Pattern Recognition · doi:10.1016/j.patcog.2018.03.005 · Cited by 601 · cited 1×
“Current methods to improve these networks’ ability to deal with rotation/flip/scale variations still heavily rely on data augmentation while intensity-level difference might be addressed by further doing domain adaptation techniques such as style transfer or adaptive batch normalization [36].”
MethodUK Biobank's cardiovascular magnetic resonance protocol
Petersen, S. E., Matthews, P. M., Francis, J. M., Robson, M. D., Zemrak, F., Boubertakh, R., Young, A. A., Hudson, S., Weale, P., Garratt, S., et al. (2016) · Journal of Cardiovascular Magnetic Resonance · doi:10.1186/s12968-016-0227-4 · Cited by 481
Self-citationA Fully Convolutional Neural Network for Cardiac Segmentation in Short-Axis MRI
Tran, P. V. (2016) · arXiv · doi:10.48550/arxiv.1604.00494 · Cited by 323
Medrano-Gracia, P., Cowan, B. R., Ambale-Venkatesh, B., Bluemke, D. A., Eng, J., Finn, J. P., Fonseca, C. G., Lima, J. A., Suinesiaputra, A., & Young, A. A. (2014) · Journal of Cardiovascular Magnetic Resonance · doi:10.1186/s12968-014-0056-2 · Cited by 98 · cited 1×
“irregular heartbeat can affect image quality) [4, 5, 6].”
Cited by
Domain Generalization: A Survey
Zhou, K., Liu, Z., Qiao, Y., Xiang, T., & Loy, C. C. (2022) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/tpami.2022.3195549 · Cited by 1,315
Multi-Centre, Multi-Vendor and Multi-Disease Cardiac Segmentation: The M&Ms Challenge
Campello, V. M., Gkontra, P., Izquierdo, C., Martin-Isla, C., Sojoudi, A., Full, P. M., Maier-Hein, K., Zhang, Y., He, Z., Ma, J., et al. (2021) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2021.3090082 · Cited by 481
“Other researchers attempted to encode higher variability by building and testing their models based on much larger datasets obtained from the UK Biobank [8].”
MethodSelf-citationMa, S., Song, K., Niu, M., Tian, H., & Yan, Y. (2024) · Journal of Intelligent Manufacturing · doi:10.1007/s10845-022-02051-7 · Cited by 31
“Chen et al. (2020) improved the generalization of convolutional neural networks through data normalization and augmentation.”
Metadata
- Authors
- Chen, C., Bai, W., Davies, R. H., Bhuva, A. N., Manisty, C. H., Augusto, J. B., Moon, J. C., Aung, N., Lee, A. M., Sanghvi, M. M., Fung, K., Paiva, J. M., Petersen, S. E., Lukaschuk, E., Piechnik, S. K., Neubauer, S., & Rueckert, D.
- Venue
- Frontiers in Cardiovascular Medicine
- Publisher
- Frontiers Media SA
- Published
- 2020-06-30
- Volume
- 7
- Pages
- 105-105
- ISSN
- 2297-055X (ISSN-L)
- OpenAlex
- W2954234616
- Cited by
- 126
- References
- 13
- FWCI
- 7.01
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.