High-Throughput Microfluidic 3D Cytotoxicity Assay for Cancer Immunotherapy (CACI-IMPACT Platform)
Open accessThe DOI matches its Crossref record; 11 of the 11 references it cites were found in a registry or an index.
Abstract
Adoptive cell transfer against solid tumors faces challenges to overcome tumor microenvironment (TME), which plays as a physical barrier and provides immuno-suppressive conditions. Classical cytotoxicity assays are widely used to measure killing ability of the engineered cytotoxic lymphocytes as therapeutics, but the results cannot represent the performance in clinical application due to the absence of the TME. This paper describes a 3D cytotoxicity assay using an injection molded plastic array culture (CACI-IMPACT) device for 3D cytotoxicity assay to assess killing abilities of cytotoxic lymphocytes in 3D microenvironment through a spatiotemporal analysis of the lymphocytes and cancer cells embedded in 3D extra cellular matrix (ECM). Rail-based microfluidic design was integrated within a single 96-well and the wells were rectangularly arrayed in 2 × 6 to enhance the experimental throughput. The rail-based microstructures facilitate hydrogel patterning with simple pipetting so that hydrogel pre-solution aspirated with 10 μl pipette can be patterned in 10 wells within 30 s. To demonstrate 3D cytotoxicity assay, we patterned HeLa cells encapsulated by collagen gel and observed infiltration, migration and cytotoxic activity of NK-92 cells against HeLa cells in the collagen matrix. We found that 3D ECM significantly reduced migration of cytotoxic lymphocytes and access to cancer cells, resulting in lower cytotoxicity compared with 2D assays. In dense ECM, the physical barrier function of the 3D matrix was enhanced, but the cytotoxic lymphocytes effectively killed cancer cells once they contacted with cancer cells. The results implied ECM significantly influences migration and cytotoxicity of cytotoxic lymphocytes. Hence, the CACI-IMPACT platform, enabling high-throughput 3D co-culture of cytotoxic lymphocyte with cancer cells, has the potential to be used for pre-clinical evaluation of cytotoxic lymphocytes engineered for immunotherapy against solid tumors.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Understanding the tumor immune microenvironment (TIME) for effective therapy
Binnewies, M., Roberts, E. W., Kersten, K., Chan, V., Fearon, D. F., Merad, M., Coussens, L. M., Gabrilovich, D. I., Ostrand-Rosenberg, S., Hedrick, C. C., et al. (2018) · Nature Medicine · doi:10.1038/s41591-018-0014-x · Cited by 6,145
Chimeric Antigen Receptor T Cells for Sustained Remissions in Leukemia
Maude, S. L., Frey, N., Shaw, P. A., Aplenc, R., Barrett, D. M., Bunin, N. J., Chew, A., Gonzalez, V. E., Zheng, Z., Lacey, S. F., et al. (2014) · New England Journal of Medicine · doi:10.1056/nejmoa1407222 · Cited by 5,413
Chimeric antigen receptor–modified T cells in chronic lymphoid leukemia
Porter, D. L., Levine, B. L., Kalos, M., Bagg, A., & June, C. H. (2011) · New England Journal of Medicine · doi:10.1056/nejmoa1103849 · Cited by 3,565
Car t cell immunotherapy for human cancer
June, C. H., O’Connor, R. S., Kawalekar, O. U., Ghassemi, S., & Milone, M. C. (2018) · Science · doi:10.1126/science.aar6711 · Cited by 3,207 · cited 1×
“The success has led to FDA approval of two CAR-T cell-based therapies, Kymriah (Novartis) and Yescarta (Gilead), and new CAR engineering strategies have been studied to improve the performance, reduce toxicity, and broaden applications of CART therapy (5, 6).”
BackgroundWolf, K., te Lindert, M., Krause, M., Alexander, S., te Riet, J., Willis, A. L., Hoffman, R. M., Figdor, C. G., Weiss, S. J., & Friedl, P. (2013) · Journal of Cell Biology · doi:10.1083/jcb.201210152 · Cited by 1,375
Kochenderfer, J. N., Wilson, W. H., Janik, J. E., Dudley, M. E., Stetler-Stevenson, M., Feldman, S. A., Maric, I., Raffeld, M., Nathan, D.-A. N., Lanier, B. J., et al. (2010) · Blood · doi:10.1182/blood-2010-04-281931 · Cited by 1,337
Engineering of functional, perfusable 3D microvascular networks on a chip
Kim, S., Lee, H., Chung, M., & Jeon, N. L. (2013) · Lab on a Chip · doi:10.1039/c3lc41320a · Cited by 872 · cited 1×
“In our experience of conducting the same 3D cytotoxicity assays using our PDMS-based coculture device (29), approximately 2 days of serial processes, including casting (7 h), punching (1 h), bonding (10m), and surface hydrophobicity restoration (>1 d), were required.”
MethodSelf-citationMicrofluidic platforms for mechanobiology
Polacheck, W. J., Li, R., Uzel, S. G. M., & Kamm, R. D. (2013) · Lab on a Chip · doi:10.1039/c3lc41393d · Cited by 272 · cited 1×
“Microfluidic-based platforms, which allow the reconstitution of complex 3D microenvironments of human tissues in in vitro by compartmentalization of multiple cell types, applying chemical and mechanical stimulations, and controlling chemical gradient (18), can be a powerful method for the assessment of lymphocyte cyto…”
MethodEvaluating natural killer cell cytotoxicity against solid tumors using a microfluidic model
Ayuso, J. M., Truttschel, R., Gong, M. M., Humayun, M., Virumbrales-Munoz, M., Vitek, R., Felder, M., Gillies, S. D., Sondel, P., Wisinski, K. B., et al. (2019) · OncoImmunology · doi:10.1080/2162402x.2018.1553477 · Cited by 142
Characterizing the role of monocytes in T cell cancer immunotherapy using a 3d microfluidic model
Lee, S. W. L., Adriani, G., Ceccarello, E., Pavesi, A., Tan, A. T., Bertoletti, A., Kamm, R. D., & Wong, S. C. (2018) · Frontiers in Immunology · doi:10.3389/fimmu.2018.00416 · Cited by 109 · cited 2×
“Specifically, microfluidic chips compartmentalized with 3D ECM gels containing tumor cells and TCR-T cell loading zones were used to assess the roles of hypoxia, inflammatory cytokines, immunosuppressive conditions induced by mTOR inhibitors, and monocytes on the cytotoxicity of TCR-T cells (20, 21), and microchips fi…”
BackgroundMethod
Cited by
A guide to the organ-on-a-chip
Leung, C. M., de Haan, P., Ronaldson-Bouchard, K., Kim, G.-A., Ko, J., Rho, H. S., Chen, Z., Habibovic, P., Jeon, N. L., Takayama, S., et al. (2022) · Nature Reviews Methods Primers · doi:10.1038/s43586-022-00118-6 · Cited by 1,116
Self-citationDadgar, N., Gonzalez-Suarez, A. M., Fattahi, P., Hou, X., Weroha, J. S., Gaspar-Maia, A., Stybayeva, G., & Revzin, A. (2020) · Microsystems & Nanoengineering · doi:10.1038/s41378-020-00201-6 · Cited by 99
Microfluidic high-throughput 3D cell culture
Ko, J., Park, D., Lee, J., Jung, S., Baek, K., Sung, K. E., Lee, J., & Jeon, N. L. (2024) · Nature Reviews Bioengineering · doi:10.1038/s44222-024-00163-8 · Cited by 88
Self-citationProteinaceous Hydrogels for Bioengineering Advanced 3D Tumor Models
Blanco‐Fernandez, B., Gaspar, V. M., Engel, E., & Mano, J. F. (2021) · Advanced Science · doi:10.1002/advs.202003129 · Cited by 78
Engineering microphysiological immune system responses on chips
Miller, C. P., Shin, W., Ahn, E. H., Kim, H. J., & Kim, D.-H. (2020) · Trends in biotechnology · doi:10.1016/j.tibtech.2020.01.003 · Cited by 74
Metadata
- Authors
- Park, D., Son, K., Hwang, Y., Ko, J., Lee, Y., Doh, J., & Jeon, N. L.
- Venue
- Frontiers in Immunology
- Publisher
- Frontiers Media SA
- Published
- 2019-05-28
- Volume
- 10
- Pages
- 1133-1133
- ISSN
- 1664-3224 (ISSN-L)
- OpenAlex
- W2947971132
- Cited by
- 96
- References
- 11
- FWCI
- 4.06
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: High-Throughput Microfluidic 3D Cytotoxicity Assay for Cancer Immunotherapy (CACI-IMPACT Platform). https://app.cochat.ai/papers/10.3389/fimmu.2019.01133
- The paper
- Park, D., Son, K., Hwang, Y., Ko, J., Lee, Y., Doh, J., & Jeon, N. L. (2019). High-Throughput Microfluidic 3D Cytotoxicity Assay for Cancer Immunotherapy (CACI-IMPACT Platform). Frontiers in Immunology. https://doi.org/10.3389/fimmu.2019.01133
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.