Improving impedance of implantable microwire multi-electrode arrays by ultrasonic electroplating of durable platinum black
Open accessThe DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.
Abstract
Implantable microelectrode arrays (MEAs) have been a boon for neural stimulation and recording experiments. Commercially available MEAs have high impedances, due to their low surface area and small tip diameters, which are suitable for recording single unit activity. Lowering the electrode impedance, but preserving the small diameter, would provide a number of advantages, including reduced stimulation voltages, reduced stimulation artifacts and improved signal-to-noise ratio. Impedance reductions can be achieved by electroplating the MEAs with platinum (Pt) black, which increases the surface area but has little effect on the physical extent of the electrodes. However, because of the low durability of Pt black plating, this method has not been popular for chronic use. Sonicoplating (i.e. electroplating under ultrasonic agitation) has been shown to improve the durability of Pt black on the base metals of macro-electrodes used for cyclic voltammetry. This method has not previously been characterized for MEAs used in chronic neural implants. We show here that sonicoplating can lower the impedances of microwire multi-electrode arrays (MMEA) by an order of magnitude or more (depending on the time and voltage of electroplating), with better durability compared to pulsed plating or traditional DC methods. We also show the improved stimulation and recording performance that can be achieved in an in vivo implantation study with the sonicoplated low-impedance MMEAs, compared to high-impedance unplated electrodes.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Neural Stimulation and Recording Electrodes
Cogan, S. F. (2008) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.10.061807.160518 · Cited by 2,243 · cited 2×
“INTRODUCTION Implantable microelectrode arrays (MEAs) have been used to record and stimulate in a number of studies in different regions of the brain (Branner et al., 2001; Vetter et al., 2004; McCreery et al., 2006; Cogan, 2008).”
MethodUnsupervised spike detection and sorting with wavelets and superparamagnetic clustering
Quiroga, R. Q., Nadasdy, Z., & Ben-Shaul, Y. (2004) · Neural Computation · doi:10.1162/089976604774201631 · Cited by 2,119
Electrical stimulation of excitable tissue: design of efficacious and safe protocols
Merrill, D. R., Bikson, M., & Jefferys, J. G. R. (2005) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2004.10.020 · Cited by 2,078 · cited 4×
“, 2000) causing the irreversible breakdown of water into O 2 and H 2 gases (Merrill et al., 2005).”
BackgroundInfluentialResponse of brain tissue to chronically implanted neural electrodes
Polikov, V. S., Tresco, P. A., & Reichert, W. M. (2005) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2005.08.015 · Cited by 1,896 · cited 1×
“However, it should be noted that the impedances in an in vivo environment are affected by variable factors such as gliosis (Rudge et al., 1989; Polikov et al., 2005) making it diffi cult to follow the impedance contributions of the electrodes themselves.”
BackgroundLarge-scale recording of neuronal ensembles
Buzsáki, G. (2004) · Nature Neuroscience · doi:10.1038/nn1233 · Cited by 1,875 · cited 2×
“…multi-electrode arrays (MMEAs) have been used widely in studies requiring both chronic and acute (<1 day) recordings and stimulations (Nicolelis et al., 1997; Buzsaki, 2004; Deadwyler and Hampson, 2004; Shi et al., 2007; Ganguly et al., 2009; O’Doherty et al., 2009; Venkatraman et al., 2009).”
MethodThermal Agitation of Electricity in Conductors
Johnson, J. B. (1928) · Physical Review · doi:10.1103/physrev.32.97 · Cited by 1,811
Selective Stimulation of Cat Sciatic Nerve Using an Array of Varying-Length Microelectrodes
Branner, A., Stein, R. B., & Normann, R. A. (2001) · Journal of Neurophysiology · doi:10.1152/jn.2001.85.4.1585 · Cited by 359 · cited 2×
“INTRODUCTION Implantable microelectrode arrays (MEAs) have been used to record and stimulate in a number of studies in different regions of the brain (Branner et al., 2001; Vetter et al., 2004; McCreery et al., 2006; Cogan, 2008).”
MethodA system for neural recording and closed-loop intracortical microstimulation in awake rodents.
Venkatraman, S., Elkabany, K., Long, J. D., Yao, Y., & Carmena, J. M. (2009) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2008.2005944 · Cited by 96 · cited 2×
“…multi-electrode arrays (MMEAs) have been used widely in studies requiring both chronic and acute (<1 day) recordings and stimulations (Nicolelis et al., 1997; Buzsaki, 2004; Deadwyler and Hampson, 2004; Shi et al., 2007; Ganguly et al., 2009; O’Doherty et al., 2009; Venkatraman et al., 2009).”
MethodRamachandran, A., Schuettler, M., Lago, N., Doerge, T., Koch, K. P., Navarro, X., Hoffmann, K.-P., & Stieglitz, T. (2006) · Journal of Neural Engineering · doi:10.1088/1741-2560/3/2/005 · Cited by 46 · cited 1×
“One study demonstrated the efficacy of a sonicoplated polyimide sieve electrode at recording and stimulating re-grown peripheral nerves, weeks after implantation (Ramachandran et al., 2006).”
Background
Cited by
A Materials Roadmap to Functional Neural Interface Design
Wellman, S. M., Eles, J. R., Ludwig, K. A., Seymour, J. P., Michelson, N. J., McFadden, W. E., Vazquez, A. L., & Kozai, T. D. Y. (2018) · Advanced Functional Materials · doi:10.1002/adfm.201701269 · Cited by 389
An Implantable 455-Active-Electrode 52-Channel CMOS Neural Probe
Lopez, C. M., Andrei, A., Mitra, S., Welkenhuysen, M., Eberle, W., Bartic, C., Puers, R., Yazicioglu, R. F., & Gielen, G. G. E. (2014) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2013.2284347 · Cited by 264
Chronic in vivo stability assessment of carbon fiber microelectrode arrays
Patel, P. R., Zhang, H., Robbins, M. T., Nofar, J. B., Marshall, S. P., Kobylarek, M. J., Kozai, T. D. Y., Kotov, N. A., & Chestek, C. A. (2016) · Journal of Neural Engineering · doi:10.1088/1741-2560/13/6/066002 · Cited by 204
Nanostructured platinum grass enables superior impedance reduction for neural microelectrodes
Boehler, C., Stieglitz, T., & Asplund, M. (2015) · Biomaterials · doi:10.1016/j.biomaterials.2015.07.036 · Cited by 179
Neural interfaces engineered via micro- and nanostructured coatings
Chen, N., Tian, L., Patil, A. C., Peng, S., Yang, I. H., Thakor, N. V., & Ramakrishna, S. (2017) · Nano Today · doi:10.1016/j.nantod.2017.04.007 · Cited by 74
Metadata
- Authors
- Desai, S. A.
- Venue
- Frontiers in Neuroengineering
- Publisher
- Frontiers Media SA
- Published
- 2010
- Volume
- 3
- Pages
- 5-5
- ISSN
- 1662-6443 (ISSN-L)
- OpenAlex
- W1970434822
- Cited by
- 126
- References
- 9
- FWCI
- 2.93
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Improving impedance of implantable microwire multi-electrode arrays by ultrasonic electroplating of durable platinum black. https://app.cochat.ai/papers/10.3389/fneng.2010.00005
- The paper
- Desai, S. A. (2010). Improving impedance of implantable microwire multi-electrode arrays by ultrasonic electroplating of durable platinum black. Frontiers in Neuroengineering. https://doi.org/10.3389/fneng.2010.00005
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.