The DOI matches its Crossref record; 50 of the 50 references it cites were found in a registry or an index.
The hybrid BCI
Open accessAbstract
Nowadays, everybody knows what a hybrid car is. A hybrid car normally has two engines to enhance energy efficiency and reduce CO2 output. Similarly, a hybrid brain-computer interface (BCI) is composed of two BCIs, or at least one BCI and another system. A hybrid BCI, like any BCI, must fulfill the following four criteria: (i) the device must rely on signals recorded directly from the brain; (ii) there must be at least one recordable brain signal that the user can intentionally modulate to effect goal-directed behaviour; (iii) real time processing; and (iv) the user must obtain feedback. This paper introduces hybrid BCIs that have already been published or are in development. We also introduce concepts for future work. We describe BCIs that classify two EEG patterns: one is the event-related (de)synchronisation (ERD, ERS) of sensorimotor rhythms, and the other is the steady-state visual evoked potential (SSVEP). Hybrid BCIs can either process their inputs simultaneously, or operate two systems sequentially, where the first system can act as a "brain switch". For example, we describe a hybrid BCI that simultaneously combines ERD and SSVEP BCIs. We also describe a sequential hybrid BCI, in which subjects could use a brain switch to control an SSVEP-based hand orthosis. Subjects who used this hybrid BCI exhibited about half the false positives encountered while using the SSVEP BCI alone. A brain switch can also rely on hemodynamic changes measured through near-infrared spectroscopy (NIRS). Hybrid BCIs can also use one brain signal and a different type of input. This additional input can be an electrophysiological signal such as the heart rate, or a signal from an external device such as an eye tracking system.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The magical number seven, plus or minus two: Some limits on our capacity for processing information.
Miller, G. A. (1994) · Psychological Review · doi:10.1037/0033-295x.101.2.343 · Cited by 17,161
Brain–computer interfaces for communication and control
Wolpaw, J. R., Birbaumer, N., McFarland, D. J., Pfurtscheller, G., & Vaughan, T. M. (2002) · Clinical Neurophysiology · doi:10.1016/s1388-2457(02)00057-3 · Cited by 7,927
Self-citationEvent-related EEG/MEG synchronization and desynchronization: basic principles
Pfurtscheller, G., & Lopes da Silva, F. H. (1999) · Clinical Neurophysiology · doi:10.1016/s1388-2457(99)00141-8 · Cited by 7,328
Self-citationMotor imagery and direct brain-computer communication
Pfurtscheller, G., & Neuper, C. (2001) · Proceedings of the IEEE · doi:10.1109/5.939829 · Cited by 1,990
Self-citationA spelling device for the paralysed
Birbaumer, N., Ghanayim, N., Hinterberger, T., Iversen, I., Kotchoubey, B., Kübler, A., Perelmouter, J., Taub, E., & Flor, H. (1999) · Nature · doi:10.1038/18581 · Cited by 1,577
Lotze, M., Montoya, P., Erb, M., Hülsmann, E., Flor, H., Klose, U., Birbaumer, N., & Grodd, W. (1999) · Journal of Cognitive Neuroscience · doi:10.1162/089892999563553 · Cited by 993 · cited 1×
“Preparation of a specific movement and imagination of the same movement involve similar cortical networks (Porro et al., 1996; Lotze et al., 1999).”
BackgroundPorro, C. A., Francescato, M. P., Cettolo, V., Diamond, M. E., Baraldi, P., Zuiani, C., Bazzocchi, M., & di Prampero, P. E. (1996) · The Journal of Neuroscience · doi:10.1523/jneurosci.16-23-07688.1996 · Cited by 924
Design and implementation of a brain-computer interface with high transfer rates
Cheng, M., Gao, X., Gao, S., & Xu, D. (2002) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2002.803536 · Cited by 818
Brain–computer interfaces: communication and restoration of movement in paralysis
Birbaumer, N., & Cohen, L. G. (2007) · The Journal of Physiology · doi:10.1113/jphysiol.2006.125633 · Cited by 754
Sitaram, R., Zhang, H., Guan, C., Thulasidas, M., Hoshi, Y., Ishikawa, A., Shimizu, K., & Birbaumer, N. (2007) · NeuroImage · doi:10.1016/j.neuroimage.2006.11.005 · Cited by 590
Müller-Putz, G. R., Scherer, R., Brauneis, C., & Pfurtscheller, G. (2005) · Journal of Neural Engineering · doi:10.1088/1741-2560/2/4/008 · Cited by 534
Self-citationBrain–computer interface using a simplified functional near-infrared spectroscopy system
Coyle, S. M., Ward, T. E., & Markham, C. M. (2007) · Journal of Neural Engineering · doi:10.1088/1741-2560/4/3/007 · Cited by 505
Vegetative response during imagined movement is proportional to mental effort
Decety, J., Jeannerod, M., Germain, M., & Pastene, J. (1991) · Behavioural Brain Research · doi:10.1016/s0166-4328(05)80033-6 · Cited by 443
Brain–computer interface systems: progress and prospects
Allison, B. Z., Wolpaw, E. W., & Wolpaw, J. R. (2007) · Expert Review of Medical Devices · doi:10.1586/17434440.4.4.463 · Cited by 420
Parasympathetic control of the heart
Levy, M. N., & Pj, M. (1984) · Unknown eBooks · Cited by 376
Cortical Modulation of theCardiovascular System
VERBERNE, A. J. M., & OWENS, N. C. (1998) · Progress in Neurobiology · doi:10.1016/s0301-0082(97)00056-7 · Cited by 351
Beta rebound after different types of motor imagery in man
Pfurtscheller, G., Neuper, C., Brunner, C., & da Silva, F. L. (2005) · Neuroscience Letters · doi:10.1016/j.neulet.2004.12.034 · Cited by 302
Self-citationA brain-controlled switch for asynchronous control applications
Mason, S. G., & Birch, G. E. (2000) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.871402 · Cited by 293
Toward a hybrid brain–computer interface based on imagined movement and visual attention
Allison, B. Z., Brunner, C., Kaiser, V, Müller-Putz, G. R., Neuper, C., & Pfurtscheller, G. (2010) · Journal of Neural Engineering · doi:10.1088/1741-2560/7/2/026007 · Cited by 291
Self-citationNaito, E., Kochiyama, T., Kitada, R., Nakamura, S., Matsumura, M., Yonekura, Y., & Sadato, N. (2002) · The Journal of Neuroscience · doi:10.1523/jneurosci.22-09-03683.2002 · Cited by 285
Brain-Computer Interfacing for Intelligent Systems
Nijholt, A., & Tan, D. (2008) · IEEE Intelligent Systems · doi:10.1109/mis.2008.41 · Cited by 279
Pfurtscheller, G., Solis-Escalante, T., Ortner, R., Linortner, P., & Muller-Putz, G. R. (2010) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2010.2040837 · Cited by 276
Self-citationEnhancing Human-Computer Interaction with Input from Active and Passive Brain-Computer Interfaces
Zander, T. O., Kothe, C., Jatzev, S., & Gaertner, M. (2010) · Human-Computer Interaction Series · doi:10.1007/978-1-84996-272-8_11 · Cited by 222
Rehabilitation with Brain-Computer Interface Systems
Pfurtscheller, G., Muller-Putz, G. R., Scherer, R., & Neuper, C. (2008) · Computer · doi:10.1109/mc.2008.432 · Cited by 222
Self-citationCould the beta rebound in the EEG be suitable to realize a “brain switch”?
Pfurtscheller, G., & Solis-Escalante, T. (2009) · Clinical Neurophysiology · doi:10.1016/j.clinph.2008.09.027 · Cited by 165
Self-citationDamen, E. J. P., & Brunia, C. H. M. (1987) · Psychophysiology · doi:10.1111/j.1469-8986.1987.tb00353.x · Cited by 163
An Introduction to Brain-Computer Interfacing
Kübler, A., & Müller, K.-R. (2007) · Toward Brain-Computer Interfacing · doi:10.7551/mitpress/7493.003.0003 · Cited by 161
BCI meeting 2005-workshop on signals and recording methods
Wolpaw, J. R., Loeb, G. E., Allison, B. Z., Donchin, E., do Nascimento, O. F., Heetderks, W., Nijboer, F., Shain, W. G., & Turner, J. N. (2006) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2006.875583 · Cited by 143
Cognitive Modulation of Time‐Dependent Primary Bradycardia
Lacey, B. C., & Lacey, J. I. (1980) · Psychophysiology · doi:10.1111/j.1469-8986.1980.tb00137.x · Cited by 127
Wriessnegger, S. C., Kurzmann, J., & Neuper, C. (2007) · International Journal of Psychophysiology · doi:10.1016/j.ijpsycho.2007.10.004 · Cited by 122
Improved signal processing approaches in an offline simulation of a hybrid brain–computer interface
Brunner, C., Allison, B. Z., Krusienski, D. J., Kaiser, V., Müller-Putz, G., Pfurtscheller, G., & Neuper, C. (2010) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2010.02.002 · Cited by 122
Self-citationBauernfeind, G., Leeb, R., Wriessnegger, S. C., & Pfurtscheller, G. (2008) · Biomedizinische Technik/Biomedical Engineering · doi:10.1515/bmt.2008.005 · Cited by 109
Self-citationPapadelis, C. L., Kourtidou‐Papadeli, C., Bamidis, P. D., & Albani, M. (2007) · Brain and Cognition · doi:10.1016/j.bandc.2007.01.001 · Cited by 106
Human Brain—Computer Interface
Pfurtscheller, G., Neuper, C., & Birbaumer, N. (2004) · Frontiers in neuroscience · doi:10.1201/9780203503584.ch14 · Cited by 92
Self-citationAutonomic response specificity during motor imagery
Oishi, K., Kasai, T., & Maeshima, T. (2000) · Journal of PHYSIOLOGICAL ANTHROPOLOGY and Applied Human Science · doi:10.2114/jpa.19.255 · Cited by 85
Interaction styles and input/output devices
Jacob, R. J. K., Leggett, J. J., Myers, B. A., & Pausch, R. F. (1993) · Behaviour and Information Technology · doi:10.1080/01449299308924369 · Cited by 75
Short‐lived brain state after cued motor imagery in naive subjects
Pfurtscheller, G., Scherer, R., Müller-Putz, G., & Lopes, F. H. D. S. (2008) · European Journal of Neuroscience · doi:10.1111/j.1460-9568.2008.06441.x · Cited by 71
Self-citationAnalysis of sensorimotor rhythms for the implementation of a brain switch for healthy subjects
Solis‐Escalante, T., Müller-Putz, G., Brunner, C., Kaiser, V., & Pfurtscheller, G. (2009) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2009.09.002 · Cited by 67
Self-citationSelf-initiation of EEG-based brain–computer communication using the heart rate response
Scherer, R., Muller-Putz, G. R., & Pfurtscheller, G. (2007) · Journal of Neural Engineering · doi:10.1088/1741-2560/4/4/l01 · Cited by 66
Self-citationMüller-Putz, G., Eder, E., Wriessnegger, S. C., & Pfurtscheller, G. (2007) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2007.09.024 · Cited by 64
Self-citationOvert foot movement detection in one single Laplacian EEG derivation
Solis‐Escalante, T., Müller-Putz, G., & Pfurtscheller, G. (2008) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2008.07.019 · Cited by 60
Self-citationGrand challenges of brain computer interfaces in the years to come
Vaadia, E., & Birbaumer, N. (2009) · Frontiers in Neuroscience · doi:10.3389/neuro.01.015.2009 · Cited by 45
Arterial baroreflex inhibition by gastric distension in rats: mediation by splanchnic afferents
Nosaka, S., Murase, S., & Murata, K. (1991) · American Journal of Physiology-Regulatory, Integrative and Comparative Physiology · doi:10.1152/ajpregu.1991.260.5.r985 · Cited by 44
BC(eye): Combining Eye-Gaze Input with Brain-Computer Interaction
Vilimek, R., & Zander, T. O. (2009) · Lecture notes in computer science · doi:10.1007/978-3-642-02710-9_66 · Cited by 38
Classification of movement-related EEG in a memorized delay task experiment
Müller-Gerking, J., Pfurtscheller, G., & Flyvbjerg, H. (2000) · Clinical Neurophysiology · doi:10.1016/s1388-2457(00)00345-x · Cited by 34
Self-citationCardiac response induced by voluntary self-paced finger movement
Florian, G., Stančák, A., & Pfurtscheller, G. (1998) · International Journal of Psychophysiology · doi:10.1016/s0167-8760(97)00075-5 · Cited by 32
Self-citationPfurtscheller, G., Leeb, R., Friedman, D. A., & Slater, M. (2007) · International Journal of Psychophysiology · doi:10.1016/j.ijpsycho.2007.11.003 · Cited by 32
Self-citationCardiac responses induced during thought-based control of a virtual environment
Pfurtscheller, G., Leeb, R., & Slater, M. (2006) · International Journal of Psychophysiology · doi:10.1016/j.ijpsycho.2006.03.001 · Cited by 28
Self-citationDoes conscious intention to perform a motor act depend on slow cardiovascular rhythms?
Pfurtscheller, G., Ortner, R., Bauernfeind, G., Linortner, P., & Neuper, C. (2009) · Neuroscience Letters · doi:10.1016/j.neulet.2009.10.060 · Cited by 26
Self-citationEvoked cardiac responses during a fixed 4 sec foreperiod preceding four different responses
BRUNIA, C. H. M., & Damen, E. J. P. (1985) · Research portal (Tilburg University) · Cited by 6
Cited by
Brain Computer Interfaces, a Review
Nicolas-Alonso, L. F., & Gomez-Gil, J. (2012) · Sensors · doi:10.3390/s120201211 · Cited by 2,143
Review of the BCI Competition IV
Tangermann, M., Müller, K.-R., Aertsen, A., Birbaumer, N., Braun, C., Brunner, C., Leeb, R., Mehring, C., Miller, K. J., Müller-Putz, G. R., et al. (2012) · Frontiers in Neuroscience · doi:10.3389/fnins.2012.00055 · Cited by 1,288
Self-citationControl strategies for active lower extremity prosthetics and orthotics: a review
Tucker, M. R., Olivier, J., Pagel, A., Bleuler, H., Bouri, M., Lambercy, O., Millán, J. D. R., Riener, R., Vallery, H., & Gassert, R. (2015) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-12-1 · Cited by 1,047
“However, EEG signals could be combined with other sensory inputs in the framework of the so-called hybrid BCIs [51,52] in order to decode user’s high-level commands more reliably.”
A comprehensive review of EEG-based brain–computer interface paradigms
Abiri, R., Borhani, S., Sellers, E. W., Jiang, Y., & Zhao, X. (2019) · Journal of Neural Engineering · doi:10.1088/1741-2552/aaf12e · Cited by 946
Zander, T. O., & Kothe, C. (2011) · Journal of Neural Engineering · doi:10.1088/1741-2560/8/2/025005 · Cited by 887
Metadata
- Authors
- Pfurtscheller, G.
- Venue
- Frontiers in Neuroscience
- Publisher
- Frontiers Media SA
- Published
- 2010
- Volume
- 4
- Pages
- 30-30
- ISSN
- 1662-453X (ISSN-L)
- OpenAlex
- W2111692383
- Cited by
- 625
- References
- 50
- FWCI
- 29.69
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.