Dosimetry for FLASH Radiotherapy: A Review of Tools and the Role of Radioluminescence and Cherenkov Emission
Open accessThe DOI matches its Crossref record; 50 of the 50 references it cites were found in a registry or an index.
Abstract
While spatial dose conformity delivered to a target volume has been pushed to its practical limits with advanced treatment planning and delivery, investigations in novel temporal dose delivery are unfolding new mechanisms. Recent advances in ultra-high dose radiotherapy, abbreviated as FLASH, indicate the potential for reduction in healthy tissue damage while preserving tumor control. FLASH therapy relies on very high dose rate of > 40Gy/sec with sub-second temporal beam modulation, taking a seemingly opposite direction from the conventional paradigm of fractionated therapy. FLASH brings unique challenges to dosimetry, beam control, and verification, as well as complexity of radiobiological effective dose through altered tissue response. In this review, we compare the dosimetric methods capable of operating under high dose rate environments. Due to excellent dose-rate independence, superior spatial (~<1 mm) and temporal (~ns) resolution achievable with Cherenkov and scintillation-based detectors, we show that luminescent detectors have a key role to play in the development of FLASH-RT, as the field rapidly progresses towards clinical adaptation. Additionally, we show that the unique ability of certain luminescence-based methods to provide tumor oxygenation maps in real-time with submillimeter resolution can elucidate the radiobiological mechanisms behind the FLASH effect. In particular, such techniques will be crucial for understanding the role of oxygen in mediating the FLASH effect.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Tumor Hypoxia: Definitions and Current Clinical, Biologic, and Molecular Aspects
Hockel, M., & Vaupel, P. (2001) · JNCI Journal of the National Cancer Institute · doi:10.1093/jnci/93.4.266 · Cited by 2,662
The Theory and Practice of Scintillation Counting
Birks, J. B. (1964) · Elsevier eBooks · doi:10.1016/c2013-0-01791-4 · Cited by 1,630
The Theory and Practice of Scintillation Counting
Birks, J. B., & Firk, F. W. K. (1965) · Physics Today · doi:10.1063/1.3047620 · Cited by 1,579
Favaudon, V., Caplier, L., Monceau, V., Pouzoulet, F., Sayarath, M., Fouillade, C., Poupon, M.-F., Brito, I., Hupé, P., Bourhis, J., et al. (2014) · Science Translational Medicine · doi:10.1126/scitranslmed.3008973 · Cited by 1,476
High Carrier Mobility in Single-Crystal Plasma-Deposited Diamond
Isberg, J., Hammersberg, J., Johansson, E., Wikström, T., Twitchen, D. J., Whitehead, A. J., Coe, S. E., & Scarsbrook, G. A. (2002) · Science · doi:10.1126/science.1074374 · Cited by 1,321
Baldock, C., De Deene, Y., Doran, S., Ibbott, G., Jirasek, A., Lepage, M., McAuley, K. B., Oldham, M., & Schreiner, L. J. (2010) · Physics in Medicine and Biology · doi:10.1088/0031-9155/55/5/r01 · Cited by 881 · cited 3×
“However, diffusion in polymer gels can still occur in the first hour post irradiation and at high dosegradients and high doses [75].”
BackgroundMethodInfluentialTransgenic Aedes aegypti Mosquitoes Transfer Genes into a Natural Population
Evans, B. R., Kotsakiozi, P., Costa-da-Silva, A. L., Ioshino, R. S., Garziera, L., Pedrosa, M. C., Malavasi, A., Virginio, J. F., Capurro, M. L., & Powell, J. R. (2019) · Scientific Reports · doi:10.1038/s41598-019-49660-6 · Cited by 732
Montay-Gruel, P., Petersson, K., Jaccard, M., Boivin, G., Germond, J.-F., Petit, B., Doenlen, R., Favaudon, V., Bochud, F., Bailat, C., et al. (2017) · Radiotherapy and Oncology · doi:10.1016/j.radonc.2017.05.003 · Cited by 692
Imaging hypoxia to improve radiotherapy outcome
Horsman, M. R., Mortensen, L. S., Petersen, J. B., Busk, M., & Overgaard, J. (2012) · Nature Reviews Clinical Oncology · doi:10.1038/nrclinonc.2012.171 · Cited by 614
Biological Benefits of Ultra-high Dose Rate FLASH Radiotherapy: Sleeping Beauty Awoken
Vozenin, M.-C., Hendry, J. H., & Limoli, C. L. (2019) · Clinical Oncology · doi:10.1016/j.clon.2019.04.001 · Cited by 484
Oxygenation status of malignant tumors: Pathogenesis of hypoxia and significance for tumor therapy
VAUPEL, P. (2001) · Seminars in Oncology · doi:10.1016/s0093-7754(01)90210-6 · Cited by 479
Clinical translation of FLASH radiotherapy: Why and how?
Bourhis, J., Montay-Gruel, P., Gonçalves Jorge, P., Bailat, C., Petit, B., Ollivier, J., Jeanneret-Sozzi, W., Ozsahin, M., Bochud, F., Moeckli, R., et al. (2019) · Radiotherapy and Oncology · doi:10.1016/j.radonc.2019.04.008 · Cited by 474
Ultra-High Dose Rate (FLASH) Radiotherapy: Silver Bullet or Fool's Gold?
Wilson, J. D., Hammond, E. M., Higgins, G. S., & Petersson, K. (2020) · Frontiers in Oncology · doi:10.3389/fonc.2019.01563 · Cited by 473 · cited 3×
“different spatial requirements are currently being investigated [27].”
BackgroundMethodInfluentialMontay-Gruel, P., Bouchet, A., Jaccard, M., Patin, D., Serduc, R., Aim, W., Petersson, K., Petit, B., Bailat, C., Bourhis, J., et al. (2018) · Radiotherapy and Oncology · doi:10.1016/j.radonc.2018.08.016 · Cited by 405 · cited 2×
“It has been shown that the FLASH effect can be triggered using electrons [9, 14, 15], x-rays [16, 17], and protons [18, 19].”
BackgroundFLASH Irradiation Spares Lung Progenitor Cells and Limits the Incidence of Radio-induced Senescence
Fouillade, C., Curras-Alonso, S., Giuranno, L., Quelennec, E., Heinrich, S., Bonnet-Boissinot, S., Beddok, A., Leboucher, S., Karakurt, H. U., Bohec, M., et al. (2020) · Clinical Cancer Research · doi:10.1158/1078-0432.ccr-19-1440 · Cited by 303
Experimental Set-up for FLASH Proton Irradiation of Small Animals Using a Clinical System
Patriarca, A., Fouillade, C., Auger, M., Martin, F., Pouzoulet, F., Nauraye, C., Heinrich, S., Favaudon, V., Meyroneinc, S., Dendale, R., et al. (2018) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/j.ijrobp.2018.06.403 · Cited by 284 · cited 6×
“It has been shown that the FLASH effect can be triggered using electrons [9, 14, 15], x-rays [16, 17], and protons [18, 19].”
BackgroundMethodInfluentialSimmons, D. A., Lartey, F. M., Schüler, E., Rafat, M., King, G., Kim, A., Ko, R., Semaan, S., Gonzalez, S., Jenkins, M., et al. (2019) · Radiotherapy and Oncology · doi:10.1016/j.radonc.2019.06.006 · Cited by 278
Roscetto, E., Contursi, P., Vollaro, A., Fusco, S., Notomista, E., & Catania, M. R. (2018) · Scientific Reports · doi:10.1038/s41598-018-35530-0 · Cited by 272
The FLASH effect depends on oxygen concentration
Adrian, G., Konradsson, E., Lempart, M., Bäck, S., Ceberg, C., & Petersson, K. (2020) · The British Journal of Radiology · doi:10.1259/bjr.20190702 · Cited by 245 · cited 1×
“[113] in vitro study supports the model and their results indicated there was no difference between cell death in hypoxic (5% oxygen concentration) cells, however cells under normoxic (20% oxygen concentration) oxygen conditions, showed increased survival from FLASH compared to conventional irradiation [113].”
ResultApplications of Liquid Scintillation Counting
(1974) · Elsevier eBooks · doi:10.1016/b978-0-12-356240-1.x5001-x · Cited by 242 · cited 1×
“In this case, energy transfer occurs mainly via solvent-solvent interactions, and ultimately to the solute by dipole-dipole energy transfer [90].”
BackgroundThe dose-rate effect revisited: Radiobiological considerations of importance in radiotherapy
Hall, E. J., & Brenner, D. J. (1991) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/0360-3016(91)90314-t · Cited by 196 · cited 1×
“Yet, the role of higher dose-rate effects has been largely undeveloped in clinical treatment [3].”
BackgroundGlaser, A. K., Zhang, R., Gladstone, D. J., & Pogue, B. W. (2014) · Physics in Medicine and Biology · doi:10.1088/0031-9155/59/14/3789 · Cited by 186 · cited 1×
“It has been shown by multiple groups that above the threshold for Cherenkov (261 keV in water) generation, the intensity of light emitted is proportional to dose [104, 105], albeit with prominent energy dependence for particles below ∼1 MeV.”
BackgroundSelf-citationNordsmark, M., Bentzen, S. M., & Overgaard, J. (1994) · Acta Oncologica · doi:10.3109/02841869409098433 · Cited by 180
BGO as a hybrid scintillator / Cherenkov radiator for cost-effective time-of-flight PET
Brünner, S., & Schaart, D. R. (2017) · Physics in Medicine and Biology · doi:10.1088/1361-6560/aa6a49 · Cited by 173 · cited 1×
“Importantly, Cherenkov light is created instantaneously [106] (∼10−12 s)”
BackgroundPratx, G., & Kapp, D. S. (2019) · Physics in Medicine & Biology · doi:10.1088/1361-6560/ab3769 · Cited by 170
A Quantitative Analysis of the Role of Oxygen Tension in FLASH Radiation Therapy
Petersson, K., Adrian, G., Butterworth, K. T., & McMahon, S. J. (2020) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/j.ijrobp.2020.02.634 · Cited by 156
The Importance of Dosimetry Standardization in Radiobiology
Desrosiers, M. F., DeWerd, L. A., Deye, J. A., Lindsay, P. E., Murphy, M. K., Mitch, M. G., Macchiarini, F., Stojadinović, S., & Stone, H. B. (2013) · Journal of Research of the National Institute of Standards and Technology · doi:10.6028/jres.118.021 · Cited by 154 · cited 1×
“The National Institute of Standards and Technology (NIST) has recommendations regarding accurate measurement and reporting of dose in preclinical radiobiological studies [26].”
BackgroundKhan, N. I., Williams, B. B., Hou, H. G., Li, H., & Swartz, H. M. (2007) · Antioxidants and Redox Signaling · doi:10.1089/ars.2007.1635 · Cited by 135
Self-citationCortés-Giraldo, M. A., & Cárabe, A. (2015) · Physics in Medicine and Biology · doi:10.1088/0031-9155/60/7/2645 · Cited by 128
Microbeam radiation therapy: Clinical perspectives
Grotzer, M. A., Schültke, E., Bräuer‐Krisch, E., & Laissue, J. A. (2015) · Physica Medica · doi:10.1016/j.ejmp.2015.02.011 · Cited by 114
Draeger, E., Sawant, A. R., Johnstone, C. D., Koger, B., Becker, S. J., Vujašković, Ž., Jackson, I., & Poirier, Y. P. (2019) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/j.ijrobp.2019.06.2545 · Cited by 111 · cited 1×
“The issue of dosimetric uncertainty in preclinical radiobiological studies and its effect on reproducibility and eventual translation to clinics has been highlighted by multiple authors [24, 25].”
BackgroundSwartz, H. M., Williams, B. B., Zaki, B. I., Hartford, A. C., Jarvis, L. A., Chen, E. Y., Comi, R. J., Ernstoff, M. S., Hou, H. G., Khan, N. I., et al. (2014) · Academic Radiology · doi:10.1016/j.acra.2013.10.011 · Cited by 101 · cited 1×
“Electron paramagnetic resonance spectroscopy and imaging with oxygen sensitive particulate or water-soluble probes can also provide direct measurement of pO2 or [O2] with sub-millimeter spatial resolution and temporal resolution <<1 s [124, 125].”
BackgroundSelf-citationEvaluation of a clinical TOF-PET detector design that achieves ⩽100 ps coincidence time resolution
Cates, J. W., & Levin, C. S. (2018) · Physics in Medicine and Biology · doi:10.1088/1361-6560/aac504 · Cited by 88
Collingridge, D. R., Young, W. K., Vojnovic, B., Wardman, P., Lynch, E. M., Hill, S. A., & Chaplin, D. J. (1997) · Radiation Research · doi:10.2307/3579340 · Cited by 87 · cited 1×
“[122] compared the standard polarographic method to an oxygen sensing system based on a time-resolved luminescence optical probe.”
MethodZhou, G. (2020) · Radiation Medicine and Protection · doi:10.1016/j.radmp.2020.02.002 · Cited by 82
Nozue, M., Lee, I., Yuan, F., Teicher, B. A., Brizel, D. M., Dewhirst, M. W., Milross, C., Milas, L., Song, C. W., Thomas, C. D., et al. (1997) · Journal of Surgical Oncology · doi:10.1002/(sici)1096-9098(199709)66:1<30::aid-jso7>3.0.co;2-o · Cited by 82
Cao, X., Allu, S., Jiang, S., Jia, M. J., Gunn, J. R., Yao, C., LaRochelle, E. P. M., Shell, J. R., Brůža, P., Gladstone, D. J., et al. (2020) · Nature Communications · doi:10.1038/s41467-020-14415-9 · Cited by 76
Self-citationPogue, B. W., Feng, J., LaRochelle, E. P. M., Brůža, P., Lin, H., Zhang, R., Shell, J. R., Dehghani, H., Davis, S. C., Vinogradov, S. A., et al. (2018) · Nature Biomedical Engineering · doi:10.1038/s41551-018-0220-3 · Cited by 75
Self-citationImpact of Target Oxygenation on the Chemical Track Evolution of Ion and Electron Radiation
Boscolo, D., Krämer, M., Fuß, M., Durante, M., & Scifoni, E. (2020) · International Journal of Molecular Sciences · doi:10.3390/ijms21020424 · Cited by 70
Tumor physiologic response to combretastatin A4 phosphate assessed by MRI
Zhao, D., Jiang, L., Hahn, E. W., & Mason, R. P. (2005) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/j.ijrobp.2005.03.009 · Cited by 68
Real-time dosimetry with radiochromic films
Casolaro, P., Campajola, L., Breglio, G., Buontempo, S., Consales, M., Cusano, A., Cutolo, A., Capua, F. D., Fienga, F., & Vaiano, P. (2019) · Scientific Reports · doi:10.1038/s41598-019-41705-0 · Cited by 67 · cited 2×
“Nonetheless, attempts have been made at real-time readout of radiochromic film [73, 74].”
BackgroundStudies on the Cherenkov Effect for Improved Time Resolution of TOF-PET
Brünner, S., Gruber, L., Marton, J., Suzuki, K., & Hirtl, A. (2013) · IEEE Transactions on Nuclear Science · doi:10.1109/tns.2013.2281667 · Cited by 66
Eling, L., Bouchet, A., Némoz, C., Djonov, V., Balosso, J., Laissue, J. A., Bräuer‐Krisch, E., Adam, J., & Serduc, R. (2019) · Radiotherapy and Oncology · doi:10.1016/j.radonc.2019.06.030 · Cited by 61
Sørensen, M., Horsman, M. R., Cumming, P. D., Munk, O. L., & Keiding, S. (2005) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/j.ijrobp.2005.02.044 · Cited by 56
Minimum dose rate estimation for pulsed FLASH radiotherapy: A dimensional analysis
Zhou, S., Zheng, D., Fan, Q., Yan, Y., Wang, S., Lei, Y., Besemer, A. E., Zhou, C., & Enke, C. A. (2020) · Medical Physics · doi:10.1002/mp.14181 · Cited by 42
Levy, K., Natarajan, S., Wang, J., Chow, S. K.-Y., Eggold, J. T., Loo, P. E., Manjappa, R., Lartey, F. M., Schüler, E., Skinner, L. B., et al. (2019) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.1101/2019.12.12.873414 · Cited by 29 · cited 1×
“Multiple groups have now replicated the FLASH effect in different murine organs [10, 11] and in superficial treatments in animal models such as mini-pigs, cats [12] and zebrafish [13].”
BackgroundSoliman, Y. S., Pellicioli, P., Beshir, W. B., Abdel-Fattah, A. A., Fahim, R. A., Krisch, M. H., & Bräuer‐Krisch, E. (2020) · Physica Medica · doi:10.1016/j.ejmp.2020.03.007 · Cited by 29
O’Leary, M., Boscolo, D., Breslin, N., Brown, J. M. C., Dolbnya, I. P., Emerson, C., Figueira, C., Fox, O., Grimes, D. R., Ivošev, V., et al. (2018) · Scientific Reports · doi:10.1038/s41598-018-21813-z · Cited by 25
Richardson, R. B. (2008) · International Journal of Radiation Biology · doi:10.1080/09553000802389686 · Cited by 14 · cited 1×
“The OER is dependent on particle type and LET as shown in Figure 12B [114].”
MethodTerasawa, K., Borak, T. B., Doke, T., Fuse, T., Hara, K.-I., Kikuchi, J., Kitamura, H., Suzuki, S., & Uchihori, Y. (2005) · Japanese Journal of Applied Physics · doi:10.1143/jjap.44.7608 · Cited by 3 · cited 9×
“Multiple preclinical studies have been performed using the experimental Oriatron eRT6- 6MeV and Kinetron 4.5 MeV linear accelerator (PMB-Alcen, Peynier, France).”
MethodInfluential
Cited by
Towards clinical translation of FLASH radiotherapy
Vozenin, M.-C., Bourhis, J., & Durante, M. (2022) · Nature Reviews Clinical Oncology · doi:10.1038/s41571-022-00697-z · Cited by 363
Metadata
- Authors
- Ashraf, M. R., Rahman, M., Zhang, R., Williams, B. B., Gladstone, D. J., Pogue, B. W., & Bruza, P.
- Venue
- Frontiers in Physics
- Publisher
- Frontiers Media SA
- Published
- 2020-08-21
- Volume
- 8
- ISSN
- 2296-424X (ISSN-L)
- OpenAlex
- W3033370983
- Cited by
- 189
- References
- 50
- FWCI
- 13.44
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.