Inter-Individual Variation during Transcranial Direct Current Stimulation and Normalization of Dose Using MRI-Derived Computational Models
Open accessAbstract
BACKGROUND: Transcranial Direct Current Stimulation (tDCS) is a non-invasive, versatile, and safe neuromodulation technology under investigation for the treatment of neuropsychiatric disorders, adjunct to rehabilitation, and cognitive enhancement in healthy adults. Despite promising results, there is variability in responsiveness. One potential source of variability is the intensity of current delivered to the brain which is a function of both the operator controlled tDCS dose (electrode montage and total applied current) and subject specific anatomy. We are interested in both the scale of this variability across anatomical typical adults and methods to normalize inter-individual variation by customizing tDCS dose. Computational FEM simulations are a standard technique to predict brain current flow during tDCS and can be based on subject specific anatomical MRI. OBJECTIVE: To investigate this variability, we modeled multiple tDCS montages across three adults (ages 34-41, one female). RESULTS: Conventional pad stimulation led to diffuse modulation with maximum current flow between the pads across all subjects. There was high current flow directly under the pad for one subject while the location of peak induced cortical current flow was variable. The High-Definition tDCS montage led to current flow restricted to within the ring perimeter across all subjects. The current flow profile across all subjects and montages was influenced by details in cortical gyri/sulci. CONCLUSION: This data suggests that subject specific modeling can facilitate consistent and more efficacious tDCS.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Nitsche, M. A., & Paulus, W. (2000) · The Journal of Physiology · doi:10.1111/j.1469-7793.2000.t01-1-00633.x · Cited by 5,656
Brunoni, A. R., Nitsche, M. A., Bolognini, N., Bikson, M., Wagner, T., Merabet, L., Edwards, D. J., Valero-Cabre, A., Rotenberg, A., Pascual-Leone, A., et al. (2012) · Brain stimulation · doi:10.1016/j.brs.2011.03.002 · Cited by 1,445
Self-citationDatta, A., Bansal, V., Diaz, J., Patel, J., Reato, D., & Bikson, M. (2009) · Brain Stimulation · doi:10.1016/j.brs.2009.03.005 · Cited by 1,290
Self-citationLang, N., Siebner, H. R., Ward, N. S., Lee, L., Nitsche, M. A., Paulus, W., Rothwell, J. C., Lemon, R. N., & Frackowiak, R. S. (2005) · European Journal of Neuroscience · doi:10.1111/j.1460-9568.2005.04233.x · Cited by 769
Radman, T., Ramos, R. L., Brumberg, J. C., & Bikson, M. (2009) · Brain Stimulation · doi:10.1016/j.brs.2009.03.007 · Cited by 702
Self-citationFregni, F., Boggio, P. S., Lima, M. C., Ferreira, M. J. L., Wagner, T., Rigonatti, S. P., Castro, A. W., Souza, D. R., Riberto, M., Freedman, S. D., et al. (2006) · Pain · doi:10.1016/j.pain.2006.02.023 · Cited by 693
Transcranial direct current stimulation: A computer-based human model study
Wagner, T., Fregni, F., Fecteau, S., Grodzinsky, A., Zahn, M., & Pascual-Leone, A. (2007) · NeuroImage · doi:10.1016/j.neuroimage.2007.01.027 · Cited by 567
Computational anatomy with the SPM software
Ashburner, J. (2009) · Magnetic Resonance Imaging · doi:10.1016/j.mri.2009.01.006 · Cited by 564
Using transcranial direct-current stimulation to treat stroke patients with aphasia
Baker, J. M., Rorden, C., & Fridriksson, J. (2010) · Stroke · doi:10.1161/strokeaha.109.576785 · Cited by 516
Transcranial direct current stimulation for depression: 3-week, randomised, sham-controlled trial
Loo, C. K., Alonzo, A., Martin, D., Mitchell, P. B., Galvez, V., & Sachdev, P. (2012) · British Journal of Psychiatry · doi:10.1192/bjp.bp.111.097634 · Cited by 455
Peterchev, A. V., Wagner, T. A., Miranda, P. C., Nitsche, M. A., Paulus, W., Lisanby, S. H., Pascual-Leone, A., & Bikson, M. (2012) · Brain Stimulation · doi:10.1016/j.brs.2011.10.001 · Cited by 429
Self-citationSex Differences in Temporo-limbic and Frontal Brain Volumes of Healthy Adults
Gur, R. C. (2002) · Cerebral Cortex · doi:10.1093/cercor/12.9.998 · Cited by 406
Antal, A., Kincses, T. Z., Nitsche, M. A., Bartfai, O., & Paulus, W. (2004) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.03-0688 · Cited by 382
Datta, A., Baker, J. M., Bikson, M., & Fridriksson, J. (2011) · Brain Stimulation · doi:10.1016/j.brs.2010.11.001 · Cited by 325
Self-citationTranscranial current stimulation focality using disc and ring electrode configurations: FEM analysis
Datta, A., Elwassif, M., Battaglia, F., & Bikson, M. (2008) · Journal of Neural Engineering · doi:10.1088/1741-2560/5/2/007 · Cited by 320
Self-citationA framework to study the cortical folding patterns
Mangin, J.-F., Rivière, D., Cachia, A., Duchesnay, E., Cointepas, Y., Papadopoulos-Orfanos, D., Scifo, P., Ochiai, T., Brunelle, F., & Régis, J. (2004) · NeuroImage · doi:10.1016/j.neuroimage.2004.07.019 · Cited by 305
tDCS‐Induced Analgesia and Electrical Fields in Pain‐Related Neural Networks in Chronic Migraine
DaSilva, A. F., Mendonca, M. E., Zaghi, S., Lopes, M., DosSantos, M. F., Spierings, E. L., Bajwa, Z., Datta, A., Bikson, M., & Fregni, F. (2012) · Headache: The Journal of Head and Face Pain · doi:10.1111/j.1526-4610.2012.02141.x · Cited by 305
Self-citationBorckardt, J. J., Bikson, M., Frohman, H., Reeves, S. T., Datta, A., Bansal, V., Madan, A., Barth, K., & George, M. S. (2012) · The Journal of Pain · doi:10.1016/j.jpain.2011.07.001 · Cited by 268
Self-citationMinhas, P., Bansal, V., Patel, J., Ho, J. S., Diaz, J., Datta, A., & Bikson, M. (2010) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2010.05.007 · Cited by 267
Self-citationTranscranial direct current stimulation (tDCS) in a realistic head model
Sadleir, R. J., Vannorsdall, T. D., Schretlen, D. J., & Gordon, B. (2010) · NeuroImage · doi:10.1016/j.neuroimage.2010.03.052 · Cited by 232
Datta, A., Bikson, M., & Fregni, F. (2010) · NeuroImage · doi:10.1016/j.neuroimage.2010.04.252 · Cited by 211
Self-citationMendonca, M. E., Santana, M. B., Baptista, A. F., Datta, A., Bikson, M., Fregni, F., & Araujo, C. P. (2011) · The Journal of Pain · doi:10.1016/j.jpain.2010.12.015 · Cited by 163
Self-citationChaieb, L., Antal, A., & Paulus, W. (2008) · Visual Neuroscience · doi:10.1017/s0952523808080097 · Cited by 144
Edwards, D. J., Krebs, H. I., Rykman, A., Zipse, J., Thickbroom, G. W., Mastaglia, F. L., Pascual‐Leone, Á., & Volpe, B. T. (2009) · Restorative Neurology and Neuroscience · doi:10.3233/rnn-2009-0470 · Cited by 142
Halko, M. A., Datta, A., Plow, E. B., Scaturro, J., Bikson, M., & Merabet, L. B. (2011) · NeuroImage · doi:10.1016/j.neuroimage.2011.05.026 · Cited by 116
Self-citationLeft lateralizing transcranial direct current stimulation improves reading efficiency
Turkeltaub, P. E., Benson, J. G., Hamilton, R. H., Datta, A., Bikson, M., & Coslett, H. B. (2011) · Brain stimulation · doi:10.1016/j.brs.2011.04.002 · Cited by 116
Self-citationA pilot study on effects of 4×1 High-Definition tDCS on motor cortex excitability
Caparelli-Dáquer, E. M., Zimmermann, T. J., Mooshagian, E., Parra, L. C., Rice, J. K., Datta, A., Bikson, M., & Wassermann, E. M. (2012) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2012.6346036 · Cited by 100
Self-citationGuidelines for precise and accurate computational models of tDCS
Bikson, M., & Datta, A. (2011) · Brain stimulation · doi:10.1016/j.brs.2011.06.001 · Cited by 82
Self-citationSalvador, R., Mekonnen, A., Ruffini, G., & Miranda, P. C. (2010) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2010.5626315 · Cited by 81
Derrfuß, J., Braß, M., von Cramon, D. Y., Lohmann, G., & Amunts, K. (2007) · Human Brain Mapping · doi:10.1002/hbm.20501 · Cited by 78
Bikson, M., Bulow, P., Stiller, J. W., Datta, A., Battaglia, F., Karnup, S. V., & Postolache, T. T. (2008) · Current Treatment Options in Neurology · doi:10.1007/s11940-008-0040-y · Cited by 66
Self-citationSong, C., Schwarzkopf, D. S., Kanai, R., & Rees, G. E. (2011) · Journal of Neuroscience · doi:10.1523/jneurosci.0308-11.2011 · Cited by 43
Reduced spatial focality of electrical field in tDCS with ring electrodes due to tissue anisotropy
Suh, H. S., Lee, W. H., Cho, Y. S., Kim, J., & Kim, T. (2010) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2010.5626502 · Cited by 33
An automated method for high-definition transcranial direct current stimulation modeling
Huang, Y., Su, Y., Rorden, C., Dmochowski, J., Datta, A., & Parra, L. C. (2012) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2012.6347209 · Cited by 18
Self-citation
Cited by
Evidence-based guidelines on the therapeutic use of transcranial direct current stimulation (tDCS)
Lefaucheur, J.-P., Antal, A., Ayache, S. S., Benninger, D. H., Brunelin, J., Cogiamanian, F., Cotelli, M., De Ridder, D., Ferrucci, R., Langguth, B., et al. (2017) · Clinical Neurophysiology · doi:10.1016/j.clinph.2016.10.087 · Cited by 1,826
A technical guide to tDCS, and related non-invasive brain stimulation tools
Woods, A. J., Antal, A., Bikson, M., Boggio, P. S., Brunoni, A. R., Celnik, P., Cohen, L. G., Fregni, F., Herrmann, C. S., Kappenman, E. S., et al. (2016) · Clinical Neurophysiology · doi:10.1016/j.clinph.2015.11.012 · Cited by 1,439
Self-citationAntal, A., Alekseichuk, I., Bikson, M., Brockmöller, J., Brunoni, A. R., Chen, R., Cohen, L. G., Dowthwaite, G., Ellrich, J., Flöel, A., et al. (2017) · Clinical Neurophysiology · doi:10.1016/j.clinph.2017.06.001 · Cited by 1,301
Self-citationModulation of brain plasticity in stroke: a novel model for neurorehabilitation
Di Pino, G., Pellegrino, G., Assenza, G., Capone, F., Ferreri, F., Formica, D., Ranieri, F., Tombini, M., Ziemann, U., Rothwell, J. C., et al. (2014) · Nature Reviews Neurology · doi:10.1038/nrneurol.2014.162 · Cited by 976
Immediate neurophysiological effects of transcranial electrical stimulation
Liu, A., Vöröslakos, M., Kronberg, G., Henin, S., Krause, M. R., Huang, Y., Opitz, A., Mehta, A., Pack, C. C., Krekelberg, B., et al. (2018) · Nature Communications · doi:10.1038/s41467-018-07233-7 · Cited by 589
Self-citation
Metadata
- Authors
- Datta, A., Truong, D., Minhas, P., Parra, L. C., & Bikson, M.
- Venue
- Frontiers in Psychiatry
- Publisher
- Frontiers Media SA
- Published
- 2012
- Volume
- 3
- Pages
- 91-91
- ISSN
- 1664-0640 (ISSN-L)
- OpenAlex
- W2079748473
- Cited by
- 404
- References
- 34
- FWCI
- 10.42
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.