Antibacterial Coatings for Titanium Implants: Recent Trends and Future Perspectives
Open accessThe DOI matches its Crossref record; 103 of the 103 references it cites were found in a registry or an index.
Abstract
Titanium and its alloys are widely used as implant materials for biomedical devices owing to their high mechanical strength, biocompatibility, and corrosion resistance. However, there is a significant rise in implant-associated infections (IAIs) leading to revision surgeries, which are more complicated than the original replacement surgery. To reduce the risk of infections, numerous antibacterial agents, e.g., bioactive compounds, metal ions, nanoparticles, antimicrobial peptides, polymers, etc., have been incorporated on the surface of the titanium implant. Various coating methods and surface modification techniques, e.g., micro-arc oxidation (MAO), layer-by-layer (LbL) assembly, plasma electrolytic oxidation (PEO), anodization, magnetron sputtering, and spin coating, are exploited in the race to create a biocompatible, antibacterial titanium implant surface that can simultaneously promote tissue integration around the implant. The nature and surface morphology of implant coatings play an important role in bacterial inhibition and drug delivery. Surface modification of titanium implants with nanostructured materials, such as titanium nanotubes, enhances bone regeneration. Antimicrobial peptides loaded with antibiotics help to achieve sustained drug release and reduce the risk of antibiotic resistance. Additive manufacturing of patient-specific porous titanium implants will have a clear future direction in the development of antimicrobial titanium implants. In this review, a brief overview of the different types of coatings that are used to prevent implant-associated infections and the applications of 3D printing in the development of antibacterial titanium implants is presented.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Implant infections: adhesion, biofilm formation and immune evasion
Arciola, C. R., Campoccia, D., & Montanaro, L. (2018) · Nature Reviews Microbiology · doi:10.1038/s41579-018-0019-y · Cited by 2,241 · cited 4×
“Moreover, infection of the tissues around implant material is a significant complication of orthopedic surgery [9].”
BackgroundInfluentialTransition from acute to chronic pain after surgery
Glare, P., Aubrey, K. R., & Myles, P. S. (2019) · The Lancet · doi:10.1016/s0140-6736(19)30352-6 · Cited by 914 · cited 3×
“When an infection forms in the area around the implant, n t nly d es the operation and the implant fail, but the pati nt’s recovery time is also prolonged [3].”
BackgroundInfluentialLi, B., & Webster, T. J. (2018) · Journal of Orthopaedic Research · doi:10.1002/jor.23656 · Cited by 907
Antibacterial coatings on titanium implants
Zhao, L., Chu, P. K., Zhang, Y., & Wu, Z. (2009) · Journal of Biomedical Materials Research Part B: Applied Biomaterials · doi:10.1002/jbm.b.31463 · Cited by 866 · cited 1×
“Several antibiotics have been functionalized on titanium surfaces as a coating layer to prevent bacterial adhesion, biofouling adhesion, and biofouling from reducing the risk of infection [87].”
BackgroundGokuldoss, P. K., Kolla, S., & Eckert, J. (2017) · Materials · doi:10.3390/ma10060672 · Cited by 804
Toxicity of silver nanoparticles—Nanoparticle or silver ion?
Beer, C., Foldbjerg, R., Hayashi, Y., Sutherland, D. S., & Autrup, H. (2012) · Toxicology Letters · doi:10.1016/j.toxlet.2011.11.002 · Cited by 784 · cited 2×
“Due to the potential toxicity of high concentrations of silver and silver incor‐ porated systems, care should be taken in controlling their release [53,54].”
BackgroundOsteoimmunomodulation for the development of advanced bone biomaterials
Chen, Z., Klein, T., Murray, R. Z., Crawford, R., Chang, J., Wu, C., & Xiao, Y. (2016) · Materials Today · doi:10.1016/j.mattod.2015.11.004 · Cited by 730
Staphylococcal Biofilm Development: Structure, Regulation, and Treatment Strategies
Schilcher, K., & Horswill, A. R. (2020) · Microbiology and Molecular Biology Reviews · doi:10.1128/mmbr.00026-19 · Cited by 706 · cited 2×
“Moreover, Staphylococcus aureus has evolved to have a variety of defense mechanisms to evade the host immune system, with its biofilms exhibiting enhanced resistance to an‐ tibiotics [19].”
BackgroundImplant infections: a haven for opportunistic bacteria
Schierholz, J. M., & Beuth, J. (2001) · Journal of Hospital Infection · doi:10.1053/jhin.2001.1052 · Cited by 509 · cited 1×
“Most implants fail due to bacterial infections and inadequate tissue integration [5,6].”
BackgroundBroad-spectrum bioactivities of silver nanoparticles: the emerging trends and future prospects
Rai, M., Kon, K., Ingle, A., Duran, N., Galdiero, S., & Galdiero, M. (2014) · Applied Microbiology and Biotechnology · doi:10.1007/s00253-013-5473-x · Cited by 487 · cited 2×
“By far, silver has been one of the most widely used metals for titanium implant coat‐ ings owing to its broad‐spectrum bactericidal action [49], biocompatible [50], and stable nature [51].”
BackgroundBiofilm Formation on Dental Restorative and Implant Materials
Busscher, H. J., Rinastiti, M., Siswomihardjo, W., & van der Mei, H. C. (2010) · Journal of Dental Research · doi:10.1177/0022034510368644 · Cited by 472 · cited 4×
“Despite the several advantages of titanium alloys as implant materials, they are sus‐ ceptible to biofilm formation [11], corrosion [13], and even hypersensitivity [14,15].”
BackgroundInfluentialMouriño, V., Cattalini, J. P., & Boccaccini, A. R. (2012) · Journal of The Royal Society Interface · doi:10.1098/rsif.2011.0611 · Cited by 441 · cited 3×
“To enhance antibacterial activity and create a favorable healing environment, inorganic biofunctional metal ions [34], nanoparticles [35], and non-metals like iodine [36] and fluorine [37] are incorporated into the titanium surface.”
BackgroundSubstituted hydroxyapatite coatings of bone implants
Arcos, D., & Vallet-Regí, M. (2020) · Journal of Materials Chemistry B · doi:10.1039/c9tb02710f · Cited by 415
Campoccia, D., Montanaro, L., Speziale, P., & Arciola, C. R. (2010) · Biomaterials · doi:10.1016/j.biomaterials.2010.05.005 · Cited by 392
Greulich, C., Braun, D., Peetsch, A., Diendorf, J., Siebers, B., Epple, M., & Köller, M. (2012) · RSC Advances · doi:10.1039/c2ra20684f · Cited by 389 · cited 2×
“Due to the potential toxicity of high concentrations of silver and silver incor‐ porated systems, care should be taken in controlling their release [53,54].”
BackgroundScenery of Staphylococcus Implant Infections in Orthopedics
Montanaro, L., Speziale, P., Campoccia, D., Ravaioli, S., Cangini, I., Pietrocola, G., Giannini, S., & Arciola, C. R. (2011) · Future Microbiology · doi:10.2217/fmb.11.117 · Cited by 368
Antimicrobial Peptides: A Potent Alternative to Antibiotics
Rima, M., Rima, M., Fajloun, Z., Sabatier, J.-M., Bechinger, B., & Naas, T. (2021) · Antibiotics · doi:10.3390/antibiotics10091095 · Cited by 350
Hydroxyapatite Based Materials for Bone Tissue Engineering: A Brief and Comprehensive Introduction
Shi, H., Zhou, Z., Li, W., Fan, Y., Li, Z., & Wei, J. (2021) · Crystals · doi:10.3390/cryst11020149 · Cited by 310 · cited 1×
“Being one of the natural components of bone and teeth, hydroxyapatite (HAP)(Ca10(PO4)6(OH)2) and nano HAP are one of the most commonly used coating materials for the modification of titanium surfaces [72].”
BackgroundTitanium–Tissue Interface Reaction and Its Control With Surface Treatment
Hanawa, T. (2019) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2019.00170 · Cited by 284 · cited 1×
“Implant materials, made up of metals, alloys, ceramics, polymers, and their composites, have been extensively used in the medical field for the past five decades [1].”
BackgroundWu, S., Xu, J., Zou, L., Luo, S., Yao, R., Zheng, B., Liang, G., Wu, D., & Li, Y. (2021) · Nature Communications · doi:10.1038/s41467-021-23069-0 · Cited by 280
Three-dimensional printing of metals for biomedical applications
Ni, J., Ling, H., Zhang, S., Wang, Z., Peng, Z., Benyshek, C., Zan, R., Miri, A. K., Li, Z., Zhang, X., et al. (2019) · Materials Today Bio · doi:10.1016/j.mtbio.2019.100024 · Cited by 279
Saidin, S., Jumat, M. A., Mohd Amin, N. A. A., & Saleh Al-Hammadi, A. S. (2021) · Materials Science and Engineering: C · doi:10.1016/j.msec.2020.111382 · Cited by 279 · cited 2×
“Moreover, as most of the inorganic antibacterial agents are not Gram-specific, there is less chance of antimicrobial resistance compared to antibiotic-loaded coatings [41].”
BackgroundInfection at titanium implants with or without a clinical diagnosis of inflammation
Renvert, S., Roos‐Jansåker, A., Lindahl, C., Renvert, H., & Rutger Persson, G. (2007) · Clinical Oral Implants Research · doi:10.1111/j.1600-0501.2007.01378.x · Cited by 258 · cited 1×
“IAIs generally occur a few weeks after surgery, but there are also reports of IAIs after several years of implantation [8].”
BackgroundIonic substituted hydroxyapatite for bone regeneration applications: A review
Ressler, A., Žužić, A., Ivanišević, I., Kamboj, N., & Ivanković, H. (2021) · Open Ceramics · doi:10.1016/j.oceram.2021.100122 · Cited by 254
Iodine: Its Role in Thyroid Hormone Biosynthesis and Beyond
Sorrenti, S., Baldini, E., Pironi, D., Lauro, A., D’Orazi, V., Tartaglia, F., Tripodi, D., Lori, E., Gagliardi, F., Praticò, M., et al. (2021) · Nutrients · doi:10.3390/nu13124469 · Cited by 191 · cited 1×
“Iodine is unlikely to cause adverse effects as it already exists in the body as a part of the thyroid hormone and a trace metal [82].”
BackgroundBone regeneration with hydroxyapatite-based biomaterials
Bal, Z., Kaito, T., Korkusuz, F., & Yoshikawa, H. (2020) · Emergent Materials · doi:10.1007/s42247-019-00063-3 · Cited by 188 · cited 1×
“can stimulate implant integration by bonding directly to hard tissues [73].”
BackgroundSuspected association of an allergic reaction with titanium dental implants: A clinical report
Egusa, H., Ko, N., Shimazu, T., & Yatani, H. (2008) · Journal of Prosthetic Dentistry · doi:10.1016/s0022-3913(08)60233-4 · Cited by 188 · cited 2×
“Despite the several advantages of titanium alloys as implant materials, they are sus‐ ceptible to biofilm formation [11], corrosion [13], and even hypersensitivity [14,15].”
BackgroundGuo, T., Gulati, K., Arora, H., Han, P., Fournier, B., & Ivanovski, S. (2021) · Dental Materials · doi:10.1016/j.dental.2021.02.005 · Cited by 180 · cited 1×
“An implant must have both strong tissue integration and antimicrobial qualities for it to be effective [2,4].”
BackgroundPolymers for medical and tissue engineering applications
Ozdil, D., & Aydin, H. M. (2014) · Journal of Chemical Technology & Biotechnology · doi:10.1002/jctb.4505 · Cited by 179
Trindade, R., Albrektsson, T. O., Galli, S., Prgomet, Z., Tengvall, P., & Wennerberg, A. (2017) · Clinical Implant Dentistry and Related Research · doi:10.1111/cid.12578 · Cited by 175 · cited 2×
“Apart from preventing microbial attacks, the coatings should be biocompatible, non‐cytotoxic, and promote tissue integra‐ tion [24].”
BackgroundTracking global trends in the effectiveness of antibiotic therapy using the Drug Resistance Index
Klein, E. Y., Tseng, K. K., Pant, S., & Laxminarayan, R. (2019) · BMJ Global Health · doi:10.1136/bmjgh-2018-001315 · Cited by 174 · cited 2×
“Antibiotics are a com on solution but have serious sid effects that hould n t be ignored [10].”
BackgroundPrestat, M., & Thierry, D. (2021) · Acta Biomaterialia · doi:10.1016/j.actbio.2021.10.002 · Cited by 166 · cited 2×
“Despite the several advantages of titanium alloys as implant materials, they are sus‐ ceptible to biofilm formation [11], corrosion [13], and even hypersensitivity [14,15].”
BackgroundHealth, Maintenance, and Recovery of Soft Tissues around Implants
Wang, Y., Zhang, Y., & Miron, R. J. (2016) · Clinical Implant Dentistry and Related Research · doi:10.1111/cid.12343 · Cited by 161
Antibiotic resistance in human peri‐implantitis microbiota
Rams, T. E., Degener, J. E., & Winkelhoff, A. J. V. (2013) · Clinical Oral Implants Research · doi:10.1111/clr.12160 · Cited by 160 · cited 1×
“Studies show at least one antibiotic-resistant bacterium in patients with peri-implantitis [90].”
BackgroundLu, X., Wu, Z., Xu, K., Wang, X., Wang, S., Qiu, H., Li, X., & Chen, J. (2021) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2021.783816 · Cited by 156
Thukkaram, M., Cools, P., Nikiforov, A. Y., Rigole, P., Coenye, T., Voort, P. V. D., Laing, G. D., Vercruysse, C., Declercq, H., Morent, R., et al. (2019) · Applied Surface Science · doi:10.1016/j.apsusc.2019.144235 · Cited by 153 · cited 1×
“The ion concentrations were maintained below 300 ppb, which is considered a safe limit for the ion concentration in human blood [55].”
BackgroundZhang, G., Yang, Y., Shi, J. Z., Yao, X., Chen, W., Wei, X., Zhang, X., & Chu, P. K.-H. (2020) · Biomaterials · doi:10.1016/j.biomaterials.2020.120634 · Cited by 152 · cited 3×
“Adding quercetin suppressed the adverse effects of the dopants—Yb and Er [69].”
BackgroundWang, J., Li, J., Guo, G., Wang, Q., Tang, J. L., Zhao, Y., Qin, H., Wahafu, T., Shen, H., Liu, X., et al. (2016) · Scientific Reports · doi:10.1038/srep32699 · Cited by 152 · cited 1×
“Studies have also demonstrated the ability of silver nanoparticles to regulate the expression of biofilm–forming genes in Staphylococcus epidermidis and Staphylococcus aureus [52].”
BackgroundTowards Robust Delivery of Antimicrobial Peptides to Combat Bacterial Resistance
Drayton, M., Kizhakkedathu, J. N., & Straus, S. K. (2020) · Molecules · doi:10.3390/molecules25133048 · Cited by 145
Point-of-care antimicrobial coating protects orthopaedic implants from bacterial challenge
Xi, W., Hegde, V. V., Zoller, S. D., Park, H. Y., Hart, C. M., Kondo, T., Hamad, C. D., Hu, Y. W., Loftin, A. H., Johansen, D., et al. (2021) · Nature Communications · doi:10.1038/s41467-021-25383-z · Cited by 141 · cited 1×
“Studies with cyclic antibacterial tests would be more reliable for clinical translation [93].”
BackgroundLin, J., Hu, J., Wang, W., Liu, K., Zhou, C., Liu, Z., Kong, S., Lin, S., Deng, Y., & Guo, Z. (2020) · Chemical Engineering Journal · doi:10.1016/j.cej.2020.125783 · Cited by 137
Vu, A. A., Robertson, S. F., Ke, D., Bandyopadhyay, A. K., & Bose, S. (2019) · Acta Biomaterialia · doi:10.1016/j.actbio.2019.05.020 · Cited by 136 · cited 1×
“The coating inhibited the growth of Escherichia coli and Staphylococcus aureus, and the in vivo studies confirmed the non-cytotoxic nature of the coatings [78].”
BackgroundSurface chemistry influences implant‐mediated host tissue responses
Kamath, S., Bhattacharyya, D., Padukudru, C., Timmons, R. B., & Tang, L. (2008) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.31649 · Cited by 132 · cited 1×
“Most research in recent years has focused more on implant surface design to prevent infections [12].”
BackgroundShimabukuro, M. (2020) · Antibiotics · doi:10.3390/antibiotics9100716 · Cited by 132 · cited 3×
“By far, silver has been one of the most widely used metals for titanium implant coat‐ ings owing to its broad‐spectrum bactericidal action [49], biocompatible [50], and stable nature [51].”
BackgroundCerium-doped hydroxyapatite/collagen coatings on titanium for bone implants
Ciobanu, G., & Harja, M. (2018) · Ceramics International · doi:10.1016/j.ceramint.2018.07.290 · Cited by 126 · cited 2×
“59% Staphylococcus aureus were eradicated [77]”
Antimicrobial and Antifouling Polymeric Agents for Surface Functionalization of Medical Implants
Zeng, Q., Zhu, Y., Yu, B., Sun, Y., Ding, X., Chen, X., Wu, Y., Tang, Z., & Xu, F. (2018) · Biomacromolecules · doi:10.1021/acs.biomac.8b00399 · Cited by 119 · cited 2×
“, inorganic elements [29], antibiotics [30], antimicrobial peptides [31], polymers [32], and hybrid inorganic-organic moieties [33], that effectively prevent biofilm formation and enhance tissue integration.”
BackgroundChen, J., Shi, X., Zhu, Y., Chen, Y., Gao, M., Gao, H., Liu, L., Wang, L., Mao, C., & Wang, Y. (2020) · Theranostics · doi:10.7150/thno.38388 · Cited by 110
Implant Infection and Infection Resistant Materials: A Mini Review
Arciola, C. R., Alvi, F. I., An, Y. H., Campoccia, D., & Montanaro, L. (2005) · The International Journal of Artificial Organs · doi:10.1177/039139880502801109 · Cited by 105 · cited 2×
“Coat‐ ing titanium implants with antimicrobial agents has been one of the common strategies to prevent IAIs [16] (Figure 2).”
BackgroundXu, N., Fu, J., Zhao, L., Chu, P. K.-H., & Huo, K. (2020) · Advanced Healthcare Materials · doi:10.1002/adhm.202000681 · Cited by 104 · cited 2×
“, inorganic elements [29], antibiotics [30], Figure 1.”
BackgroundDiefenbeck, M., Schrader, C., Gras, F., Mückley, T., Schmidt, J., Zankovych, S., Bossert, J., Jandt, K. D., Völpel, A., Sigusch, B. W., et al. (2016) · Biomaterials · doi:10.1016/j.biomaterials.2016.05.039 · Cited by 95 · cited 1×
“Gentamicin-based coatings have been reported to enhance osseointegration and prevent osteomyelitis [92], and it is effective in treating infections caused by Staphylococcus aureus, Pseudomonas aeruginosa, and Escherichia coli.”
BackgroundHu, J., Ding, Y., Tao, B., Yuan, Z., Yang, Y., Xu, K., Li, X., liu, P., & Cai, K. (2022) · Bioactive Materials · doi:10.1016/j.bioactmat.2022.03.011 · Cited by 95
Anodised TiO2 nanotubes as a scaffold for antibacterial silver nanoparticles on titanium implants
Gunputh, U. F., Le, H., Handy, R. D., & Tredwin, C. J. (2018) · Materials Science and Engineering C · doi:10.1016/j.msec.2018.05.074 · Cited by 90 · cited 4×
“For example, TiO2 nanotubes and porous titanium surfaces serve as reservoirs for antibacterial agents and tailor their local release.”
InfluentialGentamicin-Loaded Bioactive Hydroxyapatite/Chitosan Composite Coating Electrodeposited on Titanium
Stevanović, M., Djošić, M., Janković, A., Kojić, V., Vukašinović‐Sekulić, M., Stojanovic, J. N., Odović, J., Crevar, M., Rhee, K. Y., & Mišković‐Stanković, V. (2018) · ACS Biomaterials Science & Engineering · doi:10.1021/acsbiomaterials.8b00859 · Cited by 84
Cerioli, M., Batailler, C., Conrad, A., Roux, S., Perpoint, T., Becker, A., Triffault-Fillit, C., Lustıg, S., Fessy, M.-H., Laurent, F. J., et al. (2020) · Frontiers in Medicine · doi:10.3389/fmed.2020.513242 · Cited by 81
Zhang, G., Wu, Z., Yang, Y., Shi, J., Lv, J., Fang, Y., Shen, Z. Z., Lv, Z., Li, P., Yao, X., et al. (2021) · Chemical Engineering Journal · doi:10.1016/j.cej.2021.131155 · Cited by 80
Peng, J., Liu, P., Wan, P., Sun, J. Y., Dong, X., Ma, Z., Gan, D., Liu, P., & Shen, J. (2021) · Journal of Hazardous Materials · doi:10.1016/j.jhazmat.2021.125110 · Cited by 69
Zhang, F., Hu, Q., Wei, Y., Meng, W., Wang, R., Liu, J., Nie, Y., Luo, R., Wang, Y., & Shen, B. (2022) · Chemical Engineering Journal · doi:10.1016/j.cej.2022.134802 · Cited by 69
Healthy Aims: Developing New Medical Implants and Diagnostic Equipment
Hodgins, D., Bertsch, A., Post, N., Frischholz, M., Volckaerts, B., Spensley, J., Wasikiewicz, J. M., Higgins, H., von Stetten, F., & Kenney, L. P. J. (2008) · IEEE Pervasive Computing · doi:10.1109/mprv.2008.8 · Cited by 68 · cited 2×
“Pertinently, implants are widely used in orthopedics and dentistry to retain broken bones in an appropriate position or to replace damaged bones [2].”
BackgroundZhang, X., Huang, Y., Wang, B., Chang, X., Yang, H., Lan, J., Wang, S., Qiao, H., Lin, H., Han, S., et al. (2020) · Ceramics International · doi:10.1016/j.ceramint.2020.03.004 · Cited by 67 · cited 3×
“, calcium [63], strontium [64], gallium [65], bismuth [66], and rare earth metals, such as samarium [67], cerium [68], ytterbium, and erbium [69], have also been utilized to enhance the bioactive properties of titanium substrates.”
BackgroundGao, C., Li, C., Wang, C., Qin, Y., Wang, Z., Yang, F., Liu, H., Chang, F., & Wang, J. (2017) · Journal of Alloys and Compounds · doi:10.1016/j.jallcom.2017.08.078 · Cited by 66 · cited 1×
“Moreover, it has been reported that zinc-containing coatings help osteoblast differentiation and improve the corrosion resistance of titanium implants [59,60].”
BackgroundMinkiewicz-Zochniak, A., Jarzynka, S., Iwańska, A., Strom, K., Iwańczyk, B., Bartel, M., Mazur, M., Pietruczuk-Padzik, A., Konieczna, M., AUGUSTYNOWICZ-KOPEĆ, E. M., et al. (2021) · Materials · doi:10.3390/ma14082030 · Cited by 65 · cited 1×
“Staphylococcus aureus can form multicellular biofilms that shield the bacterial cells from the host immune system [18].”
BackgroundZhao, Q., Yi, L., Jiang, L., Ma, Y., Lin, H. Q., & Dong, J. (2018) · Nanomedicine Nanotechnology Biology and Medicine · doi:10.1016/j.nano.2018.12.006 · Cited by 65 · cited 2×
“Zinc/Strontium-doped titanium dioxide microporous coating promoted osteoblast adhesion and inhibited the growth of Staphylococcus aureus [71].”
BackgroundVeronesi, F., Giavaresi, G., Fini, M., Longo, G., Ioannidu, C. A., d’Abusco, A. S., Superti, F., Panzini, G., Misiano, C., Palattella, A., et al. (2016) · Materials Science and Engineering C · doi:10.1016/j.msec.2016.08.076 · Cited by 64 · cited 1×
“These are increasingly utilized in creating strong, robust, antibacterial surfaces for implants that can withstand high corrosion and wear resistance [85].”
BackgroundLuo, J., Mamat, B., Yue, Z., Zhang, N., Xu, X., Li, Y., Su, Z., Ma, C., Zang, F., & Wang, Y. (2021) · Colloids and Interface Science Communications · doi:10.1016/j.colcom.2021.100435 · Cited by 59 · cited 2×
“, electrochemical deposition [25], ionized jet deposition (IJD) [26], sol‐gel method [27], micro‐arc oxidation [28], etc.”
MethodGuo, C., Cui, W., Wang, X., Lu, X., Zhang, L., Li, X., Li, W., Zhang, W., & Chen, J. (2020) · ACS Omega · doi:10.1021/acsomega.0c00986 · Cited by 57
Priyadarshini, B., Ramya, S., Shinyjoy, E., Kavitha, L., Gopi, D., & Vijayalakshmi, U. (2021) · Journal of Materials Research and Technology · doi:10.1016/j.jmrt.2021.03.009 · Cited by 54 · cited 1×
“, calcium [63], strontium [64], gallium [65], bismuth [66], and rare earth metals, such as samarium [67], cerium [68], ytterbium, and erbium [69], have also been utilized to enhance the bioactive properties of titanium substrates.”
BackgroundLiu, Y., Lee, Y.-T., Huang, T.-C., Lin, G., Chen, Y., Lee, B., & Tung, K. (2021) · ACS Applied Bio Materials · doi:10.1021/acsabm.0c01535 · Cited by 53 · cited 1×
“, calcium [63], strontium [64], gallium [65], bismuth [66], and rare earth metals, such as samarium [67], cerium [68], ytterbium, and erbium [69], have also been utilized to enhance the bioactive properties of titanium substrates.”
BackgroundOsteoblast Response to Copper-Doped Microporous Coatings on Titanium for Improved Bone Integration
Wang, L., Ni, X., Zhang, F., Peng, Z. J., Yu, F., Zhang, L.-B., Li, B., Jiao, Y., Li, Y., Yang, B. J., et al. (2021) · Nanoscale Research Letters · doi:10.1186/s11671-021-03602-2 · Cited by 48 · cited 3×
“Coatings containing these metal ions increase the biocompatibility of the implants [57].”
BackgroundDong, J., Fang, D., Zhang, L., Shan, Q., & Huang, Y. (2019) · Materialia · doi:10.1016/j.mtla.2019.100209 · Cited by 47 · cited 3×
“A coating comprising titanium nanotubes doped with gallium demonstrated excellent biocompatibility with osteoblasts and produced significant anti-inflammatory and antibacterial activity [65].”
BackgroundMethodZhang, L., Yang, X., Gopalakrishnan, S., Li, K., Han, Y., & Rotello, V. M. (2021) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.1c04895 · Cited by 47
Bassous, N. J., Jones, C. L., & Webster, T. J. (2019) · Acta Biomaterialia · doi:10.1016/j.actbio.2019.06.055 · Cited by 45
Chen, C., Chang, J.-H., Srimaneepong, V., Wen, J.-Y., Tung, O.-H., Yang, C.-H., Lin, H., Lee, T.-H., Han, Y. N., & Huang, H. (2020) · Surface and Coatings Technology · doi:10.1016/j.surfcoat.2020.126125 · Cited by 45 · cited 2×
“, electrochem‐ ical treatment, plasma ion implantation [38], plasma electrolytic oxidation [39], sol‐gel [40], micro‐arc oxidation [28], etc.”
MethodPawar, V. S., Topkar, H., & Srivastava, R. (2018) · International Journal of Biological Macromolecules · doi:10.1016/j.ijbiomac.2018.04.166 · Cited by 44 · cited 1×
“Povidone-Iodine, commonly known as Betadine, is a well-known iodine-based effective antiseptic used to coat implant surfaces [83].”
BackgroundGhilini, F., Fagali, N., Pissinis, D. E., Benitez, G. A., & Schilardi, P. L. (2021) · ACS Applied Bio Materials · doi:10.1021/acsabm.1c00613 · Cited by 44
Maher, S., Linklater, D. P., Rastin, H., Liao, S. T.-Y., de Sousa, K. M., Lima-Marques, L., Kingshott, P., Thissen, H. W., Ivanova, E. P., & Lošić, D. (2021) · ACS Biomaterials Science & Engineering · doi:10.1021/acsbiomaterials.1c01030 · Cited by 42
Zarghami, V., Ghorbani, M., Bagheri, K. P., & Shokrgozar, M. A. (2021) · Materials Chemistry and Physics · doi:10.1016/j.matchemphys.2021.124432 · Cited by 42 · cited 3×
“Chitosan, coated with a thin layer of melittin and loaded with the antibiotics vancomycin and Oxacillin Spin coating and casting method The coatings were able to eradicate Methicillin-resistant Staphylococcus aureus (MRSA) and Vancomycin Resistant Staphylococcus aureus (VRSA) at the early stages [95]”
BackgroundInfluentialStändert, V., Borcherding, K., Bormann, N., Schmidmaier, G., Grunwald, I., & Wildemann, B. (2021) · Bioactive Materials · doi:10.1016/j.bioactmat.2021.01.012 · Cited by 41 · cited 2×
“, inorganic elements [29], antibiotics [30], Figure 1.”
BackgroundReview on Surface Treatment for Implant Infection via Gentamicin and Antibiotic Releasing Coatings
Tiwari, A. K., Sharma, P., Vishwamitra, B., & Singh, G. (2021) · Coatings · doi:10.3390/coatings11081006 · Cited by 40 · cited 1×
“Belonging to the class of amino glycans, the drug is used to treat a multitude of infections caused by aerobic Gram-negative bacteria, and the efficiency of its bactericidal action depends on its concentration [91].”
BackgroundPanda, S., Behera, B. P., Bhutia, S. K., Biswas, C. K., & Paul, S. (2022) · Journal of Alloys and Compounds · doi:10.1016/j.jallcom.2022.165662 · Cited by 40
Drug-release dynamics and antibacterial activities of chitosan/cefazolin coatings on Ti implants
Chen, S., Chien, H., Cheng, C., Huang, H.-M., Song, T.-Y., Chen, Y.-C., Wu, C.-H., Hsueh, Y., Wang, Y., & Ou, S. (2021) · Progress in Organic Coatings · doi:10.1016/j.porgcoat.2021.106385 · Cited by 40 · cited 2×
“Chitosan/cefazolin Electrophoretic deposition Nearly 100% bactericidal activity against Escherichia coli was shown by the coating which has the highest drug concentration [98]”
BackgroundIn Vitro Biological Characterization of Silver-Doped Anodic Oxide Coating on Titanium
Oleshko, O., Liubchak, I., Husak, Y., Korniienko, V. V., Yusupova, A., Oleshko, T. B., Banasiuk, R., Szkodo, M., Matros-Taranets, I., Kazek‐Kęsik, A., et al. (2020) · Materials · doi:10.3390/ma13194359 · Cited by 36 · cited 2×
“The coatings were highly biocompatible, providing an appropriate environment for osteogenic cell growth and proliferation, with increased collagen production around the coated region [56].”
BackgroundEfficacy of eluted antibiotics through 3D printed femoral implants
Benmassaoud, M. M., Kohama, C., Kim, T. W. B., Kadlowec, J. A., Foltiny, B., Mercurio, T., & Ranganathan, S. I. (2019) · Biomedical Microdevices · doi:10.1007/s10544-019-0395-8 · Cited by 33
Zhang, Y., Hu, K., Xing, X., Zhang, J., Zhang, M., Ma, X., Shi, R., & Zhang, L. (2020) · Macromolecular Bioscience · doi:10.1002/mabi.202000194 · Cited by 33
Suchý, T., Vištějnová, L., Šupová, M., Klein, P., Bartoš, M., Kolinko, Y., Blassová, T., Tonar, Z., Pokorný, M., Sucharda, Z., et al. (2021) · Biomedicines · doi:10.3390/biomedicines9050531 · Cited by 33
Pihl, M., Galli, S., Jimbo, R., & Andersson, M. (2021) · Journal of Biomedical Materials Research Part B Applied Biomaterials · doi:10.1002/jbm.b.34838 · Cited by 32 · cited 6×
“Osseointegration was unaffected in rabbit tibia models, and a two-fold increase in Bone-to-Implant Contact (BIC%), which refers to the percentage of the implant surface in direct contact with bone, was observed for the AMP-coated samples compared to the control sample [45].”
ResultInfluentialNovel Coatings to Minimize Bacterial Adhesion and Promote Osteoblast Activity for Titanium Implants
Camargo, S. E. A., Roy, T., Carey, P. H., Fares, C., Ren, F., Clark, A. E., & Esquivel‐Upshaw, J. F. (2020) · Journal of Functional Biomaterials · doi:10.3390/jfb11020042 · Cited by 31 · cited 1×
“The quarternized samples exhibited enhanced antibacterial activity against Porphyromonas gingivalis compared to the nonquarternized and non-coated titanium substrates, which can be attributed to the presence of nitrogen atoms that can rupture the cell wall and cell proliferation [86].”
BackgroundStaphylococcus aureus biofilms: an opportunistic pathogen with multidrug resistance
Silva‐Santana, G., Cabral-Oliveira, G. G., de Oliveira, D. R., Nogueira, B. A., Pereira-Ribeiro, P. M. A., & Mattos‐Guaraldi, A. L. (2020) · Reviews in Medical Microbiology · doi:10.1097/mrm.0000000000000223 · Cited by 30 · cited 2×
“Among the pathogenic bacteria that cause IAIs, the Gram‐ positive Staphylococcus aureus is the most widely studied [17].”
BackgroundMultifunctional calcium phosphate based coatings on titanium implants with integrated trace elements
Wolf‐Brandstetter, C., Beutner, R., Hess, R., Bierbaum, S., Wagner, K., Scharnweber, D., Gbureck, U., & Moseke, C. (2019) · Biomedical Materials · doi:10.1088/1748-605x/ab5d7b · Cited by 30 · cited 1×
“, calcium [63], strontium [64], gallium [65], bismuth [66], and rare earth metals, such as samarium [67], cerium [68], ytterbium, and erbium [69], have also been utilized to enhance the bioactive properties of titanium substrates.”
BackgroundElectrophoretic Deposition of Gentamicin-Loaded ZnHNTs-Chitosan on Titanium
Humayun, A., Luo, Y., & Mills, D. K. (2020) · Coatings · doi:10.3390/coatings10100944 · Cited by 30 · cited 2×
“79 cm2/unit area of the sample was observed in disc diffusion assay for Staphylococcus aureus [96]”
BackgroundMethodSaveleva, М. S., Vlădescu, A., Cotruț, C. M., der Meeren, L. V., Surmeneva, M. A., Анатольевич, С. Р., Parakhonskiy, B. V., & Skirtach, A. G. (2019) · Journal of Materials Chemistry B · doi:10.1039/c9tb01287g · Cited by 29 · cited 4×
“At optimal concentrations, certain metal ions and metal oxide nanoparticles can be therapeutic [33].”
BackgroundInfluentialSteckiewicz, K. P., & Inkielewicz‐Stępniak, I. (2020) · Nanomaterials · doi:10.3390/nano10040658 · Cited by 28
Meza-Siccha, A. S., Aguilar-Luis, M. Á., Silva-Caso, W. G., Mazulis, F., Salazar, C. B., & del Valle-Mendoza, J. (2019) · International Journal of Dentistry · doi:10.1155/2019/4292976 · Cited by 28
Ciobanu, G., & Harja, M. (2019) · Nanomaterials · doi:10.3390/nano9121696 · Cited by 28 · cited 3×
“Titanium substrates coated with bismuth-doped nanohydroxyapatite were bactericidal to Escherichia coli and Staphylococcus aureus and exhibited improved radiopacity [66].”
BackgroundYamaguchi, S., Le, P. T. M., Shintani, S. A., Takadama, H., Ito, M., Ferraris, S., & Spriano, S. (2021) · Nanomaterials · doi:10.3390/nano11092199 · Cited by 27 · cited 2×
“5% of Iodine into Titanium About 99% of bactericidal activity was observed for Methicillin-resistant Staphylococcus aureus, Staphylococcus aureus, Escherichia coli, and Staphylococcus epidermidis [84]”
BackgroundMethodKaleli‐Can, G., Özgüzar, H. F., Kahriman, S., Türkal, M., Göçmen, J. S., Yurtçu, E., & Mutlu, M. (2020) · Materials Today Communications · doi:10.1016/j.mtcomm.2020.101565 · Cited by 21
A retrospective study of antibacterial iodine-coated implants for postoperative infection
Shirai, T., Tsuchiya, H., Terauchi, R., Tsuchida, S., Mizoshiri, N., Mori, Y., Takeuchi, A., Hayashi, K., Yamamoto, N., Ikoma, K., et al. (2019) · Medicine · doi:10.1097/md.0000000000017932 · Cited by 21
Cu2+ Release from Polylactic Acid Coating on Titanium Reduces Bone Implant-Related Infection
Zhang, C., Li, X., Xiao, D., Zhao, Q., Chen, S., Yang, F., Liu, J., & Duan, K. (2022) · Journal of Functional Biomaterials · doi:10.3390/jfb13020078 · Cited by 21 · cited 1×
“The coatings featured cytocompatibility, enhanced facture-end union, and callus formation [61].”
BackgroundEarly osseointegration of strontium-doped coatings on titanium implants in an osteoporotic rat model
Katunar, M. R., Pastore, J. I., Cisilino, A. P., Merlo, J. L., Alonso, L. S., Baca, M., Haddad, K., Ceré, S., & Ballarre, J. (2022) · Surface and Coatings Technology · doi:10.1016/j.surfcoat.2022.128159 · Cited by 19 · cited 1×
“Strontiumincorporated ceramics have been reported to enhance bactericidal action and promote bone growth and regeneration [70].”
BackgroundDoymuş, B., Kerem, G., Karataş, A. Y., Kök, F. N., & Önder, S. (2020) · Journal of Biomaterials Applications · doi:10.1177/0885328220977765 · Cited by 18
Functional silver nanoparticles as broad-spectrum antimicrobial agents
Zhang, J., Gao, M., Gao, W., Yang, P., Meng, F., Liu, Q., & Chang, H. (2022) · New Journal of Chemistry · doi:10.1039/d2nj02769k · Cited by 18
Jakubowski, M., Voelkel, A., & Sandomierski, M. (2022) · Crystals · doi:10.3390/cryst12111520 · Cited by 17
An in vitro antiviral activity of iodine complexes against SARS-CoV-2
Altaf, I., Nadeem, M. F., Hussain, N., Nawaz, M., Raza, S., Shabbir, M. A. B., Ashraf, M. A., Ali, M. A., Hassan, S., Aziz, M. W., et al. (2021) · Archives of Microbiology · doi:10.1007/s00203-021-02430-3 · Cited by 12
Zhao, Z. (2022) · Materials Chemistry and Physics · doi:10.1016/j.matchemphys.2022.125867 · Cited by 7 · cited 2×
“To enhance antibacterial activity and create a favorable healing environment, inorganic biofunctional metal ions [34], nanoparticles [35], and non-metals like iodine [36] and fluorine [37] are incorporated into the titanium surface.”
Background
Cited by
Cui, Y.-W., Wang, L., & Zhang, L.-C. (2024) · Progress in Materials Science · doi:10.1016/j.pmatsci.2024.101277 · Cited by 252
Metadata
- Authors
- Akshaya, S., Rowlo, P. K., Dukle, A., & Nathanael, A. J.
- Venue
- Antibiotics
- Publisher
- MDPI AG
- Published
- 2022-11-29
- Volume
- 11
- Issue
- 12
- Pages
- 1719
- ISSN
- 2079-6382 (ISSN-L)
- OpenAlex
- W4311039781
- Cited by
- 165
- References
- 103
- FWCI
- 23.74
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.