Wearable Sensors for the Detection of Biomarkers for Wound Infection
The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Abstract
Infection represents a major complication that can affect wound healing in any type of wound, especially in chronic ones. There are currently certain limitations to the methods that are used for establishing a clinical diagnosis of wound infection. Thus, new, rapid and easy-to-use strategies for wound infection diagnosis need to be developed. To this aim, wearable sensors for infection diagnosis have been recently developed. These sensors are incorporated into the wound dressings that are used to treat and protect the wound, and are able to detect certain biomarkers that can be correlated with the presence of wound infection. Among these biomarkers, the most commonly used ones are pH and uric acid, but a plethora of others (lactic acid, oxygenation, inflammatory mediators, bacteria metabolites or bacteria) have also been detected using wearable sensors. In this work, an overview of the main types of wearable sensors for wound infection detection will be provided. These sensors will be divided into electrochemical, colorimetric and fluorimetric sensors and the examples will be presented and discussed comparatively.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Moreover, a wider array of indicators, including lactic acid, oxygenation levels, inflammatory mediators, bacterial metabolites, and the presence of bacteria, may be detected by wearable biosensors [218,219].”
From Biofilm Resilience: Molecular Mechanisms Driving Antibiotic Resistance in Clinical Contexts (2025) · cites this paper as [218]
In the citing paper
“Frequently seen biomarkers include pH and uric acid, which serve as significant indications of illness advancement [217,218].”
From Biofilm Resilience: Molecular Mechanisms Driving Antibiotic Resistance in Clinical Contexts (2025) · cites this paper as [218]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Technologies for Printing Sensors and Electronics Over Large Flexible Substrates: A Review
Khan, S., Lorenzelli, L., & Dahiya, R. S. (2015) · IEEE Sensors Journal · doi:10.1109/jsen.2014.2375203 · Cited by 1,225 · cited 2×
“The advent of sensor fabrication techniques such as screen-printing or inkjet printing [31] on flexible substrates has enabled the rapid progress of electrochemical wearable sensors.”
Wearable Chemical Sensors: Present Challenges and Future Prospects
Bandodkar, A. J., Jeerapan, I., & Wang, J. (2016) · ACS Sensors · doi:10.1021/acssensors.6b00250 · Cited by 778 · cited 7×
“The incorporated materials need to be biocompatible and tailored so that they can conform to the curvilinear surface of the skin [5,6].”
InfluentialWearable Biosensors: An Alternative and Practical Approach in Healthcare and Disease Monitoring
Sharma, A., Badea, M., Tiwari, S., & Marty, J. L. (2021) · Molecules · doi:10.3390/molecules26030748 · Cited by 357
Flexible pH‐Sensing Hydrogel Fibers for Epidermal Applications
Tamayol, A., Akbari, M., Zilberman, Y., Comotto, M., Lesha, E., Serex, L., Bagherifard, S., Chen, Y., Fu, G., Ameri, S. K., et al. (2016) · Advanced Healthcare Materials · doi:10.1002/adhm.201500553 · Cited by 262 · cited 6×
“These methods rely on the incorporation of pH sensitive dyes into microbeads [11,42] or fibers [43] that are later incorporated into wound dressing materials.”
InfluentialIncreased wound pH as an indicator of local wound infection in second degree burns
Ono, S., Imai, R., Ida, Y., Shibata, D., Komiya, T., & Matsumura, H. (2015) · Burns · doi:10.1016/j.burns.2014.10.023 · Cited by 252
Research works printed but not linked: 77
- Siddiqui, 2010, Chronic Wound Infection: Facts and Controversies, Clin. Dermatol., 28, 519, 10.1016/j.clindermatol.2010.03.009 · DOI · Paper page
- Sen, 2019, Human Wounds and Its Burden: An Updated Compendium of Estimates, Adv. Wound Care, 8, 39, 10.1089/wound.2019.0946 · DOI · Paper page
- Cutting, 2016, The Current Burden of Infected Wounds, Br. J. Health Care Manag., 22, 436, 10.12968/bjhc.2016.22.9.436 · doi:10.12968/bjhc.2016.22.9.436
- Li, 2021, Diagnostics for Wound Infections, Adv. Wound Care, 10, 317, 10.1089/wound.2019.1103 · DOI · Paper page
- Sazonov, 2021, Grand Challenges in Wearable Electronics, Front. Electron., 2, 1, 10.3389/felec.2021.668619 · DOI
- Nasiri, S., and Khosravani, M.R. (2020). Progress and Challenges in Fabrication of Wearable Sensors for Health Monitoring. Sens. Actuator A Phys., 312. · DOI · Paper page
- Mostafalu, P., Tamayol, A., Rahimi, R., Ochoa, M., Khalilpour, A., Kiaee, G., Yazdi, I.K., Bagherifard, S., Dokmeci, M.R., and Ziaie, B. (2018). Smart Bandage for Monitoring and Treatment of Chronic Wounds. Small, 14. · DOI · Paper page
- Kassal, 2015, Smart Bandage with Wireless Connectivity for Uric Acid Biosensing as an Indicator of Wound Status, Electrochem. Commun., 56, 6, 10.1016/j.elecom.2015.03.018 · DOI · Paper page
- Rahimi, 2018, Laser-Enabled Fabrication of Flexible and Transparent pH Sensor with near-Field Communication for in-Situ Monitoring of Wound Infection, Sens. Actuators B Chem., 267, 198, 10.1016/j.snb.2018.04.004 · DOI
- Kassal, 2017, Smart Bandage with Wireless Connectivity for Optical Monitoring of pH, Sens. Actuators B Chem., 246, 455, 10.1016/j.snb.2017.02.095 · DOI
- Atkinson, 2001, Biomarkers and Surrogate Endpoints: Preferred Definitions and Conceptual Framework, Clin. Pharmacol. Ther., 69, 89, 10.1067/mcp.2001.113989 · DOI · Paper page
- Mota, F.A.R., Pereira, S.A.P., Araújo, A.R.T.S., Passos, M.L.C., and Saraiva, M.L.M.F.S. (2021). Biomarkers in the Diagnosis of Wounds Infection: An Analytical Perspective. TrAC-Trends Anal. Chem., 143. · DOI
- Galvin, 2020, ‘Smart’ Wound Dressings for Advanced Wound Care: A Review, J. Wound Care, 29, 394, 10.12968/jowc.2020.29.7.394 · DOI
- Brown, M.S., Ashley, B., and Koh, A. (2018). Wearable Technology for Chronic Wound Monitoring: Current Dressings, Advancements, and Future Prospects. Front. Bioeng. Biotechnol., 6. · DOI · Paper page
- Tegl, 2015, Biomarkers for Infection: Enzymes, Microbes, and Metabolites, Appl. Microbiol. Biotechnol., 99, 4595, 10.1007/s00253-015-6637-7 · DOI
- Metcalf, D.G., Haalboom, M., Bowler, P.G., Gamerith, C., Sigl, E., Heinzle, A., and Burnet, M.W.M. (2019). Elevated Wound Fluid pH Correlates with Increased Risk of Wound Infection. Wound Med., 26. · DOI
- Percival, 2014, The Effects of pH on Wound Healing, Biofilms, and Antimicrobial Efficacy, Wound Repair Regen., 22, 174, 10.1111/wrr.12125 · DOI · Paper page
- Fernandez, 2012, Elevated Uric Acid Correlates with Wound Severity, Int. Wound J., 9, 139, 10.1111/j.1742-481X.2011.00870.x · DOI · Paper page
- Fernandez, M.L., Upton, Z., and Shooter, G.K. (2014). Uric Acid and Xanthine Oxidoreductase in Wound Healing. Curr. Rheumatol. Rep., 16. · DOI
- Castilla, 2012, Oxygen: Implications for Wound Healing, Adv. Wound Care, 1, 225, 10.1089/wound.2011.0319 · DOI · Paper page
- Zieker, 2011, Wound Fluid Lactate Concentration: A Helpful Marker for Diagnosing Soft-Tissue Infection in Diabetic Foot Ulcers? Preliminary Findings, Diabet. Med., 28, 175, 10.1111/j.1464-5491.2010.03123.x · DOI
- Boykin, 2010, Wound Nitric Oxide Bioactivity, J. Wound Ostomy Cont. Nurs., 37, 25, 10.1097/WON.0b013e3181c68b61 · DOI
- Simoska, 2020, Electrochemical Detection of Multianalyte Biomarkers in Wound Healing Efficacy, ACS Sens., 5, 3547, 10.1021/acssensors.0c01697 · DOI
- Wu, K., Wu, X., Chen, M., Wu, H., Jiao, Y., and Zhou, C. (2020). H2O2-Responsive Smart Dressing for Visible H2O2 Monitoring and Accelerating Wound Healing. Chem. Eng. J., 387. · DOI
- Gao, Y., Nguyen, D.T., Yeo, T., Lim, S.B., Tan, W.X., Madden, L.E., Jin, L., Long, J.Y.K., Aloweni, F.A.B., and Liew, A.Y.J. (2021). A Flexible Multiplexed Immunosensor for Point-of-Care in Situ Wound Monitoring. Sci. Adv., 7. · DOI · Paper page
- Mannello, 2014, Omics Profiles in Chronic Venous Ulcer Wound Fluid: Innovative Applications for Translational Medicine, Expert Rev. Mol. Diagn., 14, 737, 10.1586/14737159.2014.927312 · DOI
- McClure, 2019, Inkjet-Printed Carbon Nanotube Electrodes for Measuring Pyocyanin and Uric Acid in a Wound Fluid Simulant and Culture Media, Anal. Chem., 91, 8835, 10.1021/acs.analchem.8b05591 · DOI
- Alatraktchi, F.A., Svendsen, W.E., and Molin, S. (2020). Electrochemical Detection of Pyocyanin as a Biomarker for Pseudomonas Aeruginosa: A Focused Review. Sensors, 20. · DOI · Paper page
- Worsfold, P., Poole, C., Townshend, A., and Miró, M.B.T.-E. (2019). Amperometry. Encyclopedia of Analytical Science, Academic Press. [3rd ed.].
- Liu, 2017, Embroidered Electrochemical Sensors on Gauze for Rapid Quantification of Wound Biomarkers, Biosens. Bioelectron., 98, 189, 10.1016/j.bios.2017.06.053 · DOI
- Pal, 2018, Early Detection and Monitoring of Chronic Wounds Using Low-Cost, Omniphobic Paper-Based Smart Bandages, Biosens. Bioelectron., 117, 696, 10.1016/j.bios.2018.06.060 · DOI · Paper page
- Sharifuzzaman, M., Chhetry, A., Zahed, M.A., Yoon, S.H., Park, C.I., Zhang, S., Chandra Barman, S., Sharma, S., Yoon, H., and Park, J.Y. (2020). Smart Bandage with Integrated Multifunctional Sensors Based on MXene-Functionalized Porous Graphene Scaffold for Chronic Wound Care Management. Biosens. Bioelectron., 169. · DOI
- Ashley, 2019, Skin-Inspired, Open Mesh Electrochemical Sensors for Lactate and Oxygen Monitoring, Biosens. Bioelectron., 132, 343, 10.1016/j.bios.2019.02.041 · DOI · Paper page
- Da Roz, A.L., Ferreira, M., Leite, F.d.L., and Oliveira, O.N. (2017). Electrochemical Sensors. Nanoscience and Its Applications, Elsevier. [1st ed.].
- Farghaly, 2014, Analytical Application Using Modern Electrochemical Techniques, Int. J. Electrochem. Sci., 9, 3287, 10.1016/S1452-3981(23)08010-0 · doi:10.1016/s1452-3981(23)08010-0
- Manjakkal, 2018, Printed Flexible Electrochemical pH Sensors Based on CuO Nanorods, Sens. Actuators B Chem., 263, 50, 10.1016/j.snb.2018.02.092 · DOI
- Pan, 2019, Color-Changing Smart Fibrous Materials for Naked Eye Real-Time Monitoring of Wound pH, J. Mater. Chem. B, 7, 2626, 10.1039/C9TB00195F · DOI
- Zhou, 2018, Bacteria-Responsive Intelligent Wound Dressing: Simultaneous In Situ Detection and Inhibition of Bacterial Infection for Accelerated Wound Healing, Biomaterials, 161, 11, 10.1016/j.biomaterials.2018.01.024 · DOI · Paper page
- Ochoa, M., Rahimi, R., Zhou, J., Jiang, H., Yoon, C.K., Maddipatla, D., Narakathu, B.B., Jain, V., Oscai, M.M., and Morken, T.J. (2020). Integrated Sensing and Delivery of Oxygen for Next-Generation Smart Wound Dressings. Microsyst. Nanoeng., 6. · DOI
- Yang, P., Zhu, Z., Zhang, T., Zhang, W., Chen, W., Cao, Y., Chen, M., and Zhou, X. (2019). Orange-Emissive Carbon Quantum Dots: Toward Application in Wound pH Monitoring Based on Colorimetric and Fluorescent Changing. Small, 15. · DOI · Paper page
- Hulanicki, 1991, Chemical Sensors Definitions and Classification, Pure Appl. Chem., 63, 1247, 10.1351/pac199163091247 · DOI · Paper page
- Romanholo, P.V.V., Razzino, C.A., Raymundo-Pereira, P.A., Prado, T.M., Machado, S.A.S., and Sgobbi, L.F. (2021). Biomimetic Electrochemical Sensors: New Horizons and Challenges in Biosensing Applications. Biosens. Bioelectron., 185. · DOI
- Egbuna, C., Patrick-Iwuanyanwu, K., Shah, M.A., Ifemeje, J., and Rasul, A. (2022). Biosensors: Components, Mechanisms, and Applications. Analytical Techniques in Bioscience, Elsevier.
- Justino, 2010, Review of Analytical Figures of Merit of Sensors and Biosensors in Clinical Applications, TrAC-Trends Anal. Chem., 29, 1172, 10.1016/j.trac.2010.07.008 · DOI
- Baig, 2019, Recent Trends in Nanomaterial-Modified Electrodes for Electroanalytical Applications, TrAC-Trends Anal. Chem., 111, 47, 10.1016/j.trac.2018.11.044 · DOI · Paper page
- Kumar, N., Shetti, N.P., Jagannath, S., and Aminabhavi, T.M. (2022). Electrochemical Sensors for the Detection of SARS-CoV-2 Virus. Chem. Eng. J., 430. · DOI · Paper page
- Maduraiveeran, 2018, Electrochemical Sensor and Biosensor Platforms Based on Advanced Nanomaterials for Biological and Biomedical Applications, Biosens. Bioelectron., 103, 113, 10.1016/j.bios.2017.12.031 · DOI · Paper page
- Ozoemena, 2017, Biomedical Electrochemical Sensors for Resource-Limited Countries, Curr. Opin. Electrochem., 3, 51, 10.1016/j.coelec.2017.06.002 · DOI
- Cheng, 2007, Screen-Printed Electrochemical (Bio)Sensors in Biomedical, Environmental and Industrial Applications, Comprehensive Analytical Chemistry, Volume 49, 497
- Williams, 2020, Electrochemical Sensors for Environmental Gas Analysis, Curr. Opin. Electrochem., 22, 145, 10.1016/j.coelec.2020.06.006 · doi:10.1016/j.coelec.2020.06.006
- Gan, 2019, Understanding Signal Amplification Strategies of Nanostructured Electrochemical Sensors for Environmental Pollutants, Curr. Opin. Electrochem., 17, 56, 10.1016/j.coelec.2019.04.016 · DOI
- Du, H., Xie, Y., and Wang, J. (2021). Nanomaterial-Sensors for Herbicides Detection Using Electrochemical Techniques and Prospect Applications. TrAC-Trends Anal. Chem., 135. · DOI
- Ananda Murthy, H.C., Gebremedhn Kelele, K., Ravikumar, C.R., Nagaswarupa, H.P., Tadesse, A., and Desalegn, T. (2021). Graphene-Supported Nanomaterials as Electrochemical Sensors: A Mini Review. Results Chem., 3. · DOI
- Si, 2020, Carbon Nanomaterials and Metallic Nanoparticles-Incorporated Electrochemical Sensors for Small Metabolites: Detection Methodologies and Applications, Curr. Opin. Electrochem., 22, 234, 10.1016/j.coelec.2020.08.007 · DOI
- Naresh, V., and Lee, N. (2021). A Review on Biosensors and Recent Development of Nanostructured Materials-Enabled Biosensors. Sensors, 21. · DOI · Paper page
- Zhu, 2015, Electrochemical Sensors and Biosensors Based on Nanomaterials and Nanostructures, Anal. Chem., 87, 230, 10.1021/ac5039863 · DOI · Paper page
- Li, 2019, Materials, structures, and functions for flexible and stretchable biomimetic sensors, Acc. Chem. Res., 52, 288, 10.1021/acs.accounts.8b00497 · DOI · Paper page
- 2018, Nanomaterial-based devices for point-of-care diagnostic applications, Chem. Soc. Rev., 47, 4697, 10.1039/C7CS00837F · DOI · Paper page
- Wu, 2019, Challenges and solutions in developing ultrasensitive biosensors, J. Am. Chem. Soc., 141, 1162, 10.1021/jacs.8b09397 · DOI · Paper page
- Bahadir, 2016, Applications of Graphene in Electrochemical Sensing and Biosensing, TrAC-Trends Anal. Chem., 76, 1, 10.1016/j.trac.2015.07.008 · doi:10.1016/j.trac.2015.07.008
- Nag, 2017, Graphene and Its Sensor-Based Applications: A Review, Sens. Actuators A, 270, 177, 10.1016/j.sna.2017.12.028 · DOI · Paper page
- Brownson, 2010, Graphene Electrochemistry: An Overview of Potential Applications, Analyst, 135, 2768, 10.1039/c0an00590h · DOI · Paper page
- Gupta, 2018, Recent Advances in Carbon Nanotube Based Electrochemical Biosensors, Int. J. Biol. Macromol., 108, 687, 10.1016/j.ijbiomac.2017.12.038 · DOI · Paper page
- Gogotsi, 2019, The Rise of MXenes, ACS Nano, 13, 8491, 10.1021/acsnano.9b06394 · DOI · Paper page
- Rahimi, 2017, Highly Stretchable Potentiometric pH Sensor Fabricated via Laser Carbonization and Machining of Carbon−Polyaniline Composite, ACS Appl. Mater. Interfaces, 9, 9015, 10.1021/acsami.6b16228 · DOI · Paper page
- Farooqui, M.F., and Shamim, A. (2016). Low Cost Inkjet Printed Smart Bandage for Wireless Monitoring of Chronic Wounds. Sci. Rep., 6. · DOI · Paper page
- Barber, R., Cameron, S., Devine, A., McCombe, A., Pourshahidi, L.K., Cundell, J., Roy, S., Mathur, A., Casimero, C., and Papakonstantinou, P. (2021). Laser Induced Graphene Sensors for Assessing pH: Application to Wound Management. Electrochem. Commun., 123. · doi:10.1016/j.elecom.2020.106914
- He, M., Ou, F., Wu, Y., Sun, X., Chen, X., Li, H., Sun, D., and Zhang, L. (2020). Smart Multi-Layer PVA Foam/ CMC Mesh Dressing with Integrated Multi-Functions for Wound Management and Infection Monitoring. Mater. Des., 194. · DOI
- Mazzara, F., Patella, B., Aiello, G., O’Riordan, A., Torino, C., Vilasi, A., and Inguanta, R. (2021). Electrochemical Detection of Uric Acid and Ascorbic Acid Using R-GO/NPs Based Sensors. Electrochim. Acta, 388. · DOI · Paper page
- Zhang, 2014, CuO Nanostructures: Synthesis, Characterization, Growth Mechanisms, Fundamental Properties, and Applications, Prog. Mater. Sci., 60, 208, 10.1016/j.pmatsci.2013.09.003 · DOI · Paper page
- Malekzad, 2017, Noble Metal Nanoparticles in Biosensors: Recent Studies and Applications, Nanotechnol. Rev., 6, 301, 10.1515/ntrev-2016-0014 · DOI · Paper page
- Yang, 2019, Detection Platforms for Point-of-Care Testing Based on Colorimetric, Luminescent and Magnetic Assays: A Review, Talanta, 202, 96, 10.1016/j.talanta.2019.04.054 · DOI · Paper page
- Piriya, 2017, Colorimetric Sensors for Rapid Detection of Various Analytes, Mater. Sci. Eng. C, 78, 1231, 10.1016/j.msec.2017.05.018 · DOI · Paper page
- Chen, H.Z., Zhang, M., Bhandari, B., and Yang, C.H. (2020). Novel pH-Sensitive Films Containing Curcumin and Anthocyanins to Monitor Fish Freshness. Food Hydrocoll., 100. · DOI · Paper page
- Li, T., Li, Z., Huang, T., and Tian, L. (2021). Carbon Quantum Dot-Based Sensors for Food Safety. Sens. Actuators A Phys., 331. · DOI
- Nazri, N.A.A., Azeman, N.H., Luo, Y., and A Bakar, A.A. (2021). Carbon Quantum Dots for Optical Sensor Applications: A Review. Opt. Laser Technol., 139. · DOI · Paper page
- Darwish, I.A., Khalil, N.Y., Bakheit, A.H., and Alzoman, N.Z. (2012). A Highly Sensitive Fluorimetric Method For Determination of Lenalidomide in Its Bulk Form and Capsules via Derivatization with Fluorescamine. Chem. Cent. J., 6. · doi:10.1186/1752-153x-6-118
Cited by
Biofilm Resilience: Molecular Mechanisms Driving Antibiotic Resistance in Clinical Contexts
Almatroudi, A. (2025) · Biology · doi:10.3390/biology14020165 · Cited by 303
Metadata
- Authors
- Pusta, A., Tertiș, M., Cristea, C., & Mirel, S.
- Venue
- Biosensors
- Publisher
- MDPI AG
- Published
- 2021-12-21
- Volume
- 12
- Issue
- 1
- Pages
- 1
- ISSN
- 2079-6374
- Cited by
- 80
- References
- 5
- Language
- en
- Funders
- Iuliu Hatieganu University of Medicine and Pharmacy (1032/57/13.01.2021)
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Wearable Sensors for the Detection of Biomarkers for Wound Infection. https://app.cochat.ai/papers/10.3390/bios12010001
- The paper
- Pusta, A., Tertiș, M., Cristea, C., & Mirel, S. (2021). Wearable Sensors for the Detection of Biomarkers for Wound Infection. Biosensors. https://doi.org/10.3390/bios12010001
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.