CoChat

Advances in Antimicrobial Resistance Monitoring Using Sensors and Biosensors: A Review

Reynoso, Eduardo C., Laschi, Serena, Palchetti, Ilaria, Torres, Eduardo · 2021 · Chemosensors
Cited by 70

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Abstract

The indiscriminate use and mismanagement of antibiotics over the last eight decades have led to one of the main challenges humanity will have to face in the next twenty years in terms of public health and economy, i.e., antimicrobial resistance. One of the key approaches to tackling antimicrobial resistance is clinical, livestock, and environmental surveillance applying methods capable of effectively identifying antimicrobial non-susceptibility as well as genes that promote resistance. Current clinical laboratory practices involve conventional culture-based antibiotic susceptibility testing (AST) methods, taking over 24 h to find out which medication should be prescribed to treat the infection. Although there are techniques that provide rapid resistance detection, it is necessary to have new tools that are easy to operate, are robust, sensitive, specific, and inexpensive. Chemical sensors and biosensors are devices that could have the necessary characteristics for the rapid diagnosis of resistant microorganisms and could provide crucial information on the choice of antibiotic (or other antimicrobial medicines) to be administered. This review provides an overview on novel biosensing strategies for the phenotypic and genotypic determination of antimicrobial resistance and a perspective on the use of these tools in modern health-care and environmental surveillance.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.3390/chemosensors9080232

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Research works printed but not linked: 199

  1. Aslam, 2018, Antibiotic resistance: A rundown of a global crisis, Infect. Drug Resist., 11, 1645, 10.2147/IDR.S173867 · DOI · Paper page
  2. Michael, 2014, The Antimicrobial Resistance Crisis: Causes, Consequences, and Management, Front. Public Health, 2, 145, 10.3389/fpubh.2014.00145 · DOI · Paper page
  3. OECD (2018). Stemming the Superbug Tide: Just A Few Dollars More. OECD Health Policy Studies, OECD Health Policy Studies, OECD Publishing. · DOI · Paper page
  4. Sims, 2020, Future perspectives of wastewater-based epidemiology: Monitoring infectious disease spread and resistance to the community level, Environ. Int., 139, 105689, 10.1016/j.envint.2020.105689 · DOI · Paper page
  5. Gelband, 2015, Tackling antimicrobial resistance at global and local scales, Trends Microbiol., 23, 524, 10.1016/j.tim.2015.06.005 · DOI
  6. Roope, 2019, The challenge of antimicrobial resistance: What economics can contribute, Science, 364, eaau4679, 10.1126/science.aau4679 · DOI · Paper page
  7. Smith, 2013, The true cost of antimicrobial resistance, BMJ Br. Med. J., 346, f1493, 10.1136/bmj.f1493 · DOI · Paper page
  8. Boolchandani, 2019, Sequencing-based methods and resources to study antimicrobial resistance, Nat. Rev. Genet., 20, 356
  9. Christaki, 2020, Antimicrobial Resistance in Bacteria: Mechanisms, Evolution, and Persistence, J. Mol. Evol., 88, 26, 10.1007/s00239-019-09914-3 · DOI · Paper page
  10. O’Neill, J. (2016). Tackling Drug-Resistant Infections Globally: Final Report and Recommendations, The Review on Antimicrobial Resistance.
  11. Chokshi, 2019, Global Contributors to Antibiotic Resistance, J. Glob. Infect. Dis., 11, 36, 10.4103/jgid.jgid_110_18 · DOI · Paper page
  12. Vikesland, 2019, Differential Drivers of Antimicrobial Resistance across the World, Acc. Chem. Res., 52, 916, 10.1021/acs.accounts.8b00643 · DOI · Paper page
  13. Vasala, 2020, Modern Tools for Rapid Diagnostics of Antimicrobial Resistance, Front. Cell. Infect. Microbiol., 10, 308, 10.3389/fcimb.2020.00308 · DOI · Paper page
  14. Aryan, 2021, The overview and perspectives of biosensors and Mycobacterium tuberculosis: A systematic review, J. Cell. Physiol., 236, 1730, 10.1002/jcp.30007 · DOI
  15. Kahlmeter, 2019, Point-Counterpoint: Differences between the European Committee on Antimicrobial Susceptibility Testing and Clinical and Laboratory Standards Institute Recommendations for Reporting Antimicrobial Susceptibility Results, J. Clin. Microbiol., 57, e01129-19, 10.1128/JCM.01129-19 · DOI
  16. Davenport, 2017, New and developing diagnostic technologies for urinary tract infections, Nat. Rev. Urol., 14, 298, 10.1038/nrurol.2017.20 · DOI · Paper page
  17. McLain, 2016, Culture-based Methods for Detection of Antibiotic Resistance in Agroecosystems: Advantages, Challenges, and Gaps in Knowledge, J. Environ. Qual., 45, 432, 10.2134/jeq2015.06.0317 · DOI
  18. Lagier, 2015, Current and Past Strategies for Bacterial Culture in Clinical Microbiology, Clin. Microbiol. Rev., 28, 208, 10.1128/CMR.00110-14 · DOI · Paper page
  19. Bauer, 1959, Single-Disk Antibiotic-Sensitivity Testing of Staphylococci: An Analysis of Technique and Results, AMA Arch. Intern. Med., 104, 208, 10.1001/archinte.1959.00270080034004 · DOI
  20. Pitruzzello, 2020, Nanophotonics for bacterial detection and antimicrobial susceptibility testing, Nanophotonics, 9, 4447, 10.1515/nanoph-2020-0388 · DOI
  21. Benkova, 2020, Antimicrobial susceptibility testing: Currently used methods and devices and the near future in clinical practice, J. Appl. Microbiol., 129, 806, 10.1111/jam.14704 · DOI · Paper page
  22. Rotilie, 1975, Microdilution Technique for Antimicrobial Susceptibility Testing of Anaerobic Bacteria, Antimicrob. Agents Chemother., 7, 311, 10.1128/AAC.7.3.311 · doi:10.1128/aac.7.3.311
  23. Dietvorst, 2020, Current and near-future technologies for antibiotic susceptibility testing and resistant bacteria detection, TrAC Trends Anal. Chem., 127, 115891, 10.1016/j.trac.2020.115891 · DOI
  24. Li, 2017, Emerging Microtechnologies and Automated Systems for Rapid Bacterial Identification and Antibiotic Susceptibility Testing, SLAS Technol., 22, 585, 10.1177/2472630317727519 · DOI
  25. Snyder, 2008, Direct comparison of the BD phoenix system with the MicroScan WalkAway system for identification and antimicrobial susceptibility testing of Enterobacteriaceae and nonfermentative gram-negative organisms, J. Clin. Microbiol., 46, 2327, 10.1128/JCM.00075-08 · doi:10.1128/jcm.00075-08
  26. Whistler, T., Sangwichian, O., Jorakate, P., Sawatwong, P., Surin, U., Piralam, B., Thamthitiwat, S., Promkong, C., and Peruski, L. (2019). Identification of Gram negative nonfermentative Bacteria: How hard can it be?. PLoS Negl. Trop. Dis., 13. · DOI
  27. McKinnon, 2018, Flow Cytometry: An Overview, Curr. Protoc. Immunol., 120, 5.1.1, 10.1002/cpim.40 · DOI · Paper page
  28. Adan, 2017, Flow cytometry: Basic principles and applications, Crit. Rev. Biotechnol., 37, 163, 10.3109/07388551.2015.1128876 · DOI · Paper page
  29. Schmit, 2021, An Overview of Flow Cytometry: Its Principles and Applications in Allergic Disease Research, Anim. Models Allerg. Dis., 2223, 169, 10.1007/978-1-0716-1001-5_13 · DOI
  30. Entenza, 2014, Rapid Detection of Staphylococcus aureus Strains with Reduced Susceptibility to Vancomycin by Isothermal Microcalorimetry, J. Clin. Microbiol., 52, 180, 10.1128/JCM.01820-13 · DOI
  31. Howell, 2012, Application of a Microcalorimetric Method for Determining Drug Susceptibility in Mycobacterium Species, J. Clin. Microbiol., 50, 16, 10.1128/JCM.05556-11 · DOI
  32. Braissant, 2010, Biomedical Use of Isothermal Microcalorimeters, Sensors, 10, 9369, 10.3390/s101009369 · doi:10.3390/s101009369
  33. Butini, 2019, Real-Time Antimicrobial Susceptibility Assay of Planktonic and Biofilm Bacteria by Isothermal Microcalorimetry, Adv. Exp. Med. Biol., 1214, 61, 10.1007/5584_2018_291 · DOI
  34. Burnham, 2017, Diagnosing antimicrobial resistance, Nat. Rev. Microbiol., 15, 697, 10.1038/nrmicro.2017.103 · DOI
  35. Bou, 2019, Matrix-Assisted Laser Desorption Ionization–Time of Flight Mass Spectrometry for the Rapid Detection of Antimicrobial Resistance Mechanisms and Beyond, Clin. Microbiol. Rev., 32, e00037-18
  36. Rentschler, S., Kaiser, L., and Deigner, H.-P. (2021). Emerging Options for the Diagnosis of Bacterial Infections and the Characterization of Antimicrobial Resistance. Int. J. Mol. Sci., 22. · DOI
  37. Schwarz, S., Cavaco, L.M., and Shen, J. (2018). Molecular Methods for Detection of Antimicrobial Resistance. Antimicrobial Resistance in Bacteria from Livestock and Companion Animals, ASM Press. · DOI
  38. Peyman, 2020, A review on impedimetric immunosensors for pathogen and biomarker detection, Med. Microbiol. Immunol., 209, 343, 10.1007/s00430-020-00668-0 · DOI · Paper page
  39. Luby, 2016, Molecular methods for assessment of antibiotic resistance in agricultural ecosystems: Prospects and challenges, J. Environ. Qual., 45, 441, 10.2134/jeq2015.07.0367 · DOI
  40. Yee, 2019, Next-Generation Sequencing Approaches to Predicting Antimicrobial Susceptibility Testing Results, Adv. Mol. Pathol., 2, 99, 10.1016/j.yamp.2019.07.008 · DOI
  41. Cook, N., D’Agostino, M., and Thompson, K.C. (2016). Chapter 3—Current status of molecular microbiological techniques for the analysis of drinking water. Molecular Microbial Diagnostic Methods, Academic Press.
  42. Laschi, 2009, Enzyme-amplified electrochemical hybridization assay based on PNA, LNA and DNA probe-modified micro-magnetic beads, Bioelectrochemistry, 76, 214, 10.1016/j.bioelechem.2009.02.012 · DOI
  43. Gupta, 2017, Peptide nucleic acids: Advanced tools for biomedical applications, J. Biotechnol., 259, 148, 10.1016/j.jbiotec.2017.07.026 · DOI · Paper page
  44. Zhao, 2020, Recent Advances in Peptide Nucleic Acids for Rapid Detection of Foodborne Pathogens, Food Anal. Methods, 13, 1956, 10.1007/s12161-020-01811-6 · DOI
  45. Toth, 2001, Electrochemical biosensors: Recommended definitions and classification, Anal. Lett., 34, 635, 10.1081/AL-100103209 · DOI · Paper page
  46. Reynoso, E.C., Torres, E., Bettazzi, F., and Palchetti, I. (2019). Trends and perspectives in immunosensors for determination of currently-used pesticides: The case of glyphosate, organophosphates, and neonicotinoids. Biosensors, 9. · DOI
  47. Palchetti, 2008, Nucleic acid biosensors for environmental pollution monitoring, Analyst, 133, 846, 10.1039/b802920m · DOI · Paper page
  48. Palchetti, I., and Mascini, M. (2010). Biosensor technology: A brief history. Sensors and Microsystems, Springer. · doi:10.1007/978-90-481-3606-3_2
  49. Leonard, 2018, Recent Advances in the Race to Design a Rapid Diagnostic Test for Antimicrobial Resistance, ACS Sens., 3, 2202, 10.1021/acssensors.8b00900 · DOI
  50. Burnham, 2020, Innovative and rapid antimicrobial susceptibility testing systems, Nat. Rev. Microbiol., 18, 299, 10.1038/s41579-020-0327-x · DOI · Paper page
  51. Bettazzi, 2019, Nanotoxicity assessment: A challenging application for cutting edge electroanalytical tools, Anal. Chim. Acta, 1072, 61, 10.1016/j.aca.2019.04.035 · DOI
  52. Ensafi, A.A. (2019). Chapter 1—An introduction to sensors and biosensors. Electrochemical Biosensors, Elsevier. · DOI
  53. Bonini, 2021, Advances in biosensing: The CRISPR/Cas system as a new powerful tool for the detection of nucleic acids, J. Pharm. Biomed. Anal., 192, 113645, 10.1016/j.jpba.2020.113645 · DOI
  54. Alp, 2011, MEMS biosensors for detection of methicillin resistant Staphylococcus aureus, Biosens. Bioelectron., 29, 1, 10.1016/j.bios.2011.07.071 · DOI
  55. Xu, 2018, An ultrasensitive electrochemical biosensor for the detection of mecA gene in methicillin-resistant Staphylococcus aureus, Biosens. Bioelectron., 99, 424, 10.1016/j.bios.2017.08.014 · DOI
  56. Bhardwaj, 2016, Bacteriophage immobilized graphene electrodes for impedimetric sensing of bacteria (Staphylococcus arlettae), Anal. Biochem., 505, 18, 10.1016/j.ab.2016.04.008 · DOI
  57. Gupta, 2019, Cell-based biosensors: Recent trends, challenges and future perspectives, Biosens. Bioelectron., 141, 111435, 10.1016/j.bios.2019.111435 · DOI · Paper page
  58. Hu, 2019, Whole-cell biosensing by siderophore-based molecular recognition and localized surface plasmon resonance, Anal. Methods, 11, 296, 10.1039/C8AY02180E · DOI
  59. Hoyos-Nogués, M., Gil, F.J., and Mas-Moruno, C. (2018). Antimicrobial Peptides: Powerful Biorecognition Elements to Detect Bacteria in Biosensing Technologies. Molecules, 23. · DOI
  60. Mach, 2011, Biosensor diagnosis of urinary tract infections: A path to better treatment?, Trends Pharmacol. Sci., 32, 330, 10.1016/j.tips.2011.03.001 · DOI
  61. Bendas, 2011, Biosensor Applications in the Field of Antibiotic Research—A Review of Recent Developments, Sensors, 11, 9450, 10.3390/s111009450 · doi:10.3390/s111009450
  62. Yoo, 2016, Optical Biosensors for the Detection of Pathogenic Microorganisms, Trends Biotechnol., 34, 7, 10.1016/j.tibtech.2015.09.012 · DOI · Paper page
  63. Jung, 2020, Cell-free biosensors for rapid detection of water contaminants, Nat. Biotechnol., 38, 1451, 10.1038/s41587-020-0571-7 · DOI · Paper page
  64. Zhou, 2021, Rapid methods for antimicrobial resistance diagnosis in contaminated soils for effective remediation strategy, TrAC Trends Anal. Chem., 137, 116203, 10.1016/j.trac.2021.116203 · DOI
  65. Li, 2019, Multisegment nanowire/nanoparticle hybrid arrays as electrochemical biosensors for simultaneous detection of antibiotics, Biosens. Bioelectron., 126, 632, 10.1016/j.bios.2018.10.025 · DOI
  66. McArthur, 2013, The Comprehensive Antibiotic Resistance Database, Antimicrob. Agents Chemother., 57, 3348, 10.1128/AAC.00419-13 · DOI · Paper page
  67. Argudín, M.A., Deplano, A., Meghraoui, A., Dodémont, M., Heinrichs, A., Denis, O., Nonhoff, C., and Roisin, S. (2017). Bacteria from Animals as a Pool of Antimicrobial Resistance Genes. Antibiotics, 6. · DOI · Paper page
  68. Behera, 2019, Emerging technologies for antibiotic susceptibility testing, Biosens. Bioelectron., 142, 111552, 10.1016/j.bios.2019.111552 · DOI
  69. Ferapontova, 2020, Electrochemical assays for microbial analysis: How far they are from solving microbiota and microbiome challenges, Curr. Opin. Electrochem., 19, 153, 10.1016/j.coelec.2019.12.005 · DOI
  70. Villa, 2020, Nanomechanical Sensors as a Tool for Bacteria Detection and Antibiotic Susceptibility Testing, Front. Mech. Eng., 6, 44, 10.3389/fmech.2020.00044 · DOI
  71. Syal, 2017, Current and emerging techniques for antibiotic susceptibility tests, Theranostics, 7, 1795, 10.7150/thno.19217 · DOI · Paper page
  72. Liu, 2021, Light-sheet skew rays enhanced U-shaped fiber-optic fluorescent immunosensor for Microcystin-LR, Biosens. Bioelectron., 176, 112902, 10.1016/j.bios.2020.112902 · doi:10.1016/j.bios.2020.112902
  73. Robison, 2019, Recent advances in environmental and clinical analysis using microring resonator-based sensors, Curr. Opin. Environ. Sci. Heal., 10, 38, 10.1016/j.coesh.2019.09.001 · DOI
  74. Gupta, B.D., Shrivastav, A.M., and Usha, S.P. (2017). Optical Sensors for Biomedical Diagnostics and Environmental Monitoring, CRC Press. [1st ed.]. · DOI
  75. Berneschi, 2020, Optical whispering gallery mode resonators for label-free detection of water contaminants, TrAC Trends Anal. Chem., 126, 115856, 10.1016/j.trac.2020.115856 · DOI
  76. Labuda, 2010, Electrochemical nucleic acid-based biosensors: Concepts, terms, and methodology (IUPAC Technical Report), Pure Appl. Chem., 82, 1161, 10.1351/PAC-REP-09-08-16 · DOI
  77. Ronkainen, 2010, Electrochemical biosensors, Chem. Soc. Rev., 39, 1747, 10.1039/b714449k · DOI · Paper page
  78. Bettazzi, 2018, Photoelectrochemical genosensors for the determination of nucleic acid cancer biomarkers, Curr. Opin. Electrochem., 12, 51, 10.1016/j.coelec.2018.07.001 · DOI
  79. Voccia, 2017, Direct determination of small RNAs using a biotinylated polythiophene impedimetric genosensor, Biosens. Bioelectron., 87, 1012, 10.1016/j.bios.2016.09.058 · doi:10.1016/j.bios.2016.09.058
  80. Sinn, 2011, Asynchronous magnetic bead rotation (AMBR) biosensor in microfluidic droplets for rapid bacterial growth and susceptibility measurements, Lab. Chip, 11, 2604, 10.1039/c0lc00734j · DOI
  81. Kinnunen, 2010, High frequency asynchronous magnetic bead rotation for improved biosensors, Appl. Phys. Lett., 97, 223701, 10.1063/1.3505492 · DOI
  82. Kinnunen, 2012, Self-Assembled Magnetic Bead Biosensor for Measuring Bacterial Growth and Antimicrobial Susceptibility Testing, Small, 8, 2477, 10.1002/smll.201200110 · DOI
  83. Wang, 2018, Label-Free Monitoring of Microorganisms and Their Responses to Antibiotics Based on Self-Powered Microbead Sensors, ACS Sens., 3, 2182, 10.1021/acssensors.8b00790 · DOI
  84. Gu, H., Xu, K., Xu, C., and Xu, B. (2006). Biofunctional magnetic nanoparticles for protein separation and pathogen detection. Chem. Commun., 941–949. · DOI · Paper page
  85. Jha, S.N. (2016). Chapter 5—Biosensor. Rapid Detection of Food Adulterants and Contaminants, Academic Press. · doi:10.1016/b978-0-12-420084-5.00005-6
  86. López Rubio, A., Fabra Rovira, M.J., Martínez Sanz, M., and Gómez-Mascaraque, L.G. (2019). Chapter 7—Nanoparticles as Biosensors for Food Quality and Safety Assessment. Nanomaterials for Food Applications, Elsevier. · DOI
  87. Watson, R.R., and Preedy, V.R. (2016). Chapter 12—Novel Strategies for Genetically Modified Organism Detection. Genetically Modified Organisms in Food, Elsevier.
  88. Reyes, 2017, Dynamic monitoring of antimicrobial resistance using magnesium zinc oxide nanostructure-modified quartz crystal microbalance, Biosens. Bioelectron., 93, 189, 10.1016/j.bios.2016.09.011 · doi:10.1016/j.bios.2016.09.011
  89. Guliy, 2020, New approach for determination of antimicrobial susceptibility to antibiotics by an acoustic sensor, Appl. Microbiol. Biotechnol., 104, 1283, 10.1007/s00253-019-10295-2 · DOI
  90. Jin, 1996, Propagation of a quasi-shear horizontal acoustic wave in Z-X lithium niobate plates [and conductivity sensor application, IEEE Trans. Ultrason. Ferroelectr. Freq. Control., 43, 491, 10.1109/58.489409 · doi:10.1109/58.489409
  91. Kasas, S., Malovichko, A., Villalba, M.I., Vela, M.E., Yantorno, O., and Willaert, R.G. (2021). Nanomotion Detection-Based Rapid Antibiotic Susceptibility Testing. Antibiotics, 10. · DOI
  92. Bassani, F., Liedl, G.L., and Wyder, P. (2005). Microelectromechanical Systems. Encyclopedia of Condensed Matter Physics, Elsevier.
  93. Bennett, 2020, Cantilever Sensors for Rapid Optical Antimicrobial Sensitivity Testing, ACS Sens., 5, 3133, 10.1021/acssensors.0c01216 · DOI
  94. Sinha Ray, S. (2013). 4—Techniques for characterizing the structure and properties of polymer nanocomposites. Woodhead Publishing Series in Composites Science and Engineering, Woodhead Publishing. · DOI
  95. Stupar, 2017, Nanomechanical sensor applied to blood culture pellets: A fast approach to determine the antibiotic susceptibility against agents of bloodstream infections, Clin. Microbiol. Infect., 23, 400, 10.1016/j.cmi.2016.12.028 · doi:10.1016/j.cmi.2016.12.028
  96. Kinnunen, 2011, Monitoring the growth and drug susceptibility of individual bacteria using asynchronous magnetic bead rotation sensors, Biosens. Bioelectron., 26, 2751, 10.1016/j.bios.2010.10.010 · DOI
  97. Sinn, 2012, Asynchronous Magnetic Bead Rotation Microviscometer for Rapid, Sensitive, and Label-Free Studies of Bacterial Growth and Drug Sensitivity, Anal. Chem., 84, 5250, 10.1021/ac300128p · DOI
  98. Kinnunen, 2014, Rapid bacterial growth and antimicrobial response using self-assembled magnetic bead sensors, Sens. Actuators B Chem., 190, 265, 10.1016/j.snb.2013.08.070 · DOI
  99. Chung, C.-Y., Wang, J.-C., and Chuang, H.-S. (2016). Rapid Bead-Based Antimicrobial Susceptibility Testing by Optical Diffusometry. PLoS ONE, 11. · DOI
  100. He, 2007, A new antimicrobial susceptibility testing method of Escherichia coli against ampicillin by MSPQC, J. Microbiol. Methods, 68, 563, 10.1016/j.mimet.2006.10.013 · doi:10.1016/j.mimet.2006.10.013
  101. Wu, 2020, Rapid and dynamic detection of antimicrobial treatment response using spectral amplitude modulation in MZO nanostructure-modified quartz crystal microbalance, J. Microbiol. Methods, 178, 106071, 10.1016/j.mimet.2020.106071 · DOI
  102. Ma, 2015, Antimicrobial Susceptibility Assays Based on the Quantification of Bacterial Lipopolysaccharides via a Label Free Lectin Biosensor, Anal. Chem., 87, 4385, 10.1021/acs.analchem.5b00165 · DOI
  103. Ren, 2013, Simultaneous and early detection of Mycobacterium tuberculosis resistance to antituberculosis drugs using an indirect series piezoelectric system, Biosens. Bioelectron., 43, 115, 10.1016/j.bios.2012.12.009 · doi:10.1016/j.bios.2012.12.009
  104. Wan, 2010, Determination of sulphate-reducing bacteria based on vancomycin-functionalised magnetic nanoparticles using a modification-free quartz crystal microbalance, Biosens. Bioelectron., 25, 1847, 10.1016/j.bios.2009.12.028 · doi:10.1016/j.bios.2009.12.028
  105. Mustazzolu, 2019, A Rapid Unraveling of the Activity and Antibiotic Susceptibility of Mycobacteria, Antimicrob. Agents Chemother., 63, e02194-18, 10.1128/AAC.02194-18 · DOI
  106. Longo, 2013, Rapid detection of bacterial resistance to antibiotics using AFM cantilevers as nanomechanical sensors, Nat. Nanotechnol., 8, 522, 10.1038/nnano.2013.120 · DOI · Paper page
  107. Etayash, 2016, Microfluidic cantilever detects bacteria and measures their susceptibility to antibiotics in small confined volumes, Nat. Commun., 7, 12947, 10.1038/ncomms12947 · DOI · Paper page
  108. Villalba, 2018, Nanomotion Detection Method for Testing Antibiotic Resistance and Susceptibility of Slow-Growing Bacteria, Small, 14, 1702671, 10.1002/smll.201702671 · doi:10.1002/smll.201702671
  109. Qureshi, 2020, Biosensors for detecting viral and bacterial infections using host biomarkers: A review, Analyst, 145, 7825, 10.1039/D0AN00896F · DOI
  110. Scognamiglio, 2016, Chapter 4—Biosensor-Based Technologies for the Detection of Pathogens and Toxins, Biosensors for Sustainable Food—New Opportunities and Technical Challenges, Volume 74, 93, 10.1016/bs.coac.2016.04.002 · DOI
  111. Ye, 2020, Portable Smartphone-Based QDs for the Visual Onsite Monitoring of Fluoroquinolone Antibiotics in Actual Food and Environmental Samples, ACS Appl. Mater. Interfaces, 12, 14552, 10.1021/acsami.9b23167 · DOI
  112. Chen, 2021, Toward Decentralizing Antibiotic Susceptibility Testing via Ready-to-Use Microwell Array and Resazurin-Aided Colorimetric Readout, Anal. Chem., 93, 1260, 10.1021/acs.analchem.0c04095 · DOI
  113. Sun, 2019, Colorimetric and Electrochemical Detection of Escherichia coli and Antibiotic Resistance Based on a p-Benzoquinone-Mediated Bioassay, Anal. Chem., 91, 7524, 10.1021/acs.analchem.8b04997 · doi:10.1021/acs.analchem.8b04997
  114. Mocan, 2017, Development of nanoparticle-based optical sensors for pathogenic bacterial detection, J. Nanobiotechnol., 15, 25, 10.1186/s12951-017-0260-y · DOI
  115. Kadlec, 2014, A Cell Phone-Based Microphotometric System for Rapid Antimicrobial Susceptibility Testing, J. Lab. Autom., 19, 258, 10.1177/2211068213491095 · DOI
  116. Nazemi, 2017, Monitoring growth and antibiotic susceptibility of Escherichia coli with photoluminescence of GaAs/AlGaAs quantum well microstructures, Biosens. Bioelectron., 93, 234, 10.1016/j.bios.2016.08.112 · DOI
  117. Tang, 2013, Rapid antibiotic susceptibility testing in a microfluidic pH sensor, Anal. Chem., 85, 2787, 10.1021/ac303282j · DOI
  118. Nag, 2020, Beta-lactam antibiotics induced bacteriolysis on LSPR sensors for assessment of antimicrobial resistance and quantification of antibiotics, Sens. Actuators B Chem., 311, 127945, 10.1016/j.snb.2020.127945 · DOI
  119. Verma, A.S., and Singh, A. (2020). Chapter 16—Nanotechnology and its applications to animal biotechnology. Animal Biotechnology, Academic Press. [2nd ed.].
  120. Barh, D., and Azevedo, V.B. (2019). Chapter 8—Single-Cell Omics in Noninvasive Diagnosis and Testing—Surface-Enhanced Raman Spectroscopy-Based Approach. Single-Cell Omics, Academic Press. · doi:10.1016/b978-0-12-817532-3.09988-6
  121. Ozaki, Y., Baranska, M., Lednev, I.K., and Wood, B.R. (2020). Chapter 13—Resonance Raman spectroscopy of hemoglobin in red blood cells. Vibrational Spectroscopy in Protein Research, Academic Press.
  122. Bi, 2020, SERS-active Au@Ag core-shell nanorod (Au@AgNR) tags for ultrasensitive bacteria detection and antibiotic-susceptibility testing, Talanta, 220, 121397, 10.1016/j.talanta.2020.121397 · DOI
  123. Zhu, 2021, Controllable design of a nano-bio aptasensing interface based on tetrahedral framework nucleic acids in an integrated microfluidic platform, Biosens. Bioelectron., 176, 112943, 10.1016/j.bios.2020.112943 · DOI
  124. Thrift, 2020, Deep Learning Analysis of Vibrational Spectra of Bacterial Lysate for Rapid Antimicrobial Susceptibility Testing, ACS Nano, 14, 15336, 10.1021/acsnano.0c05693 · DOI
  125. He, 2020, Laser-patterned paper-based sensors for rapid point-of-care detection and antibiotic-resistance testing of bacterial infections, Biosens. Bioelectron., 152, 112008, 10.1016/j.bios.2020.112008 · DOI
  126. Ucak Ozkaya, G., Durak, M.Z., Akyar, I., and Karatuna, O. (2019). Antimicrobial Susceptibility Test for the Determination of Resistant and Susceptible S. aureus and Enterococcus spp. Using a Multi-Channel Surface Plasmon Resonance Device. Diagnostics, 9. · DOI
  127. Gahlaut, 2019, Smartphone based dual mode in situ detection of viability of bacteria using Ag nanorods array, Biosens. Bioelectron., 126, 478, 10.1016/j.bios.2018.11.025 · DOI
  128. Kaushik, 2017, Accelerating bacterial growth detection and antimicrobial susceptibility assessment in integrated picoliter droplet platform, Biosens. Bioelectron., 97, 260, 10.1016/j.bios.2017.06.006 · DOI
  129. Sabhachandani, 2017, Integrated microfluidic platform for rapid antimicrobial susceptibility testing and bacterial growth analysis using bead-based biosensor via fluorescence imaging, Microchim. Acta, 184, 4619, 10.1007/s00604-017-2492-9 · DOI
  130. Wang, 2016, Characterization of Lactococcus lactis response to ampicillin and ciprofloxacin using surface-enhanced Raman spectroscopy, Anal. Bioanal. Chem., 408, 933, 10.1007/s00216-015-9184-2 · DOI
  131. Mohan, 2013, A multiplexed microfluidic platform for rapid antibiotic susceptibility testing, Biosens. Bioelectron., 49, 118, 10.1016/j.bios.2013.04.046 · DOI
  132. Chiang, 2009, Innovative antimicrobial susceptibility testing method using surface plasmon resonance, Biosens. Bioelectron., 24, 1905, 10.1016/j.bios.2008.09.020 · doi:10.1016/j.bios.2008.09.020
  133. Fu, 2020, A sensitive and rapid bacterial antibiotic susceptibility test method by surface enhanced Raman spectroscopy, Braz. J. Microbiol., 51, 875, 10.1007/s42770-020-00282-5 · DOI
  134. Gjevik, 2021, Rapid detection of antibiotic sensitivity of Staphylococcus aureus by Raman tweezers, Eur. Phys. J. Plus, 136, 233, 10.1140/epjp/s13360-021-01152-1 · DOI
  135. Simoska, 2019, Electrochemical sensors for rapid diagnosis of pathogens in real time, Analyst, 144, 6461, 10.1039/C9AN01747J · DOI · Paper page
  136. Nemr, 2019, Nanoparticle-Mediated Capture and Electrochemical Detection of Methicillin-Resistant Staphylococcus aureus, Anal. Chem., 91, 2847, 10.1021/acs.analchem.8b04792 · DOI
  137. Karbelkar, 2020, Electrochemical Diagnostics for Bacterial Infectious Diseases, ACS Infect. Dis., 6, 1567, 10.1021/acsinfecdis.0c00342 · DOI
  138. Liang, 2013, Microbial surface display of glucose dehydrogenase for amperometric glucose biosensor, Biosens. Bioelectron., 45, 19, 10.1016/j.bios.2013.01.050 · DOI
  139. Farabullini, 2007, Disposable electrochemical genosensor for the simultaneous analysis of different bacterial food contaminants, Biosens. Bioelectron., 22, 1544, 10.1016/j.bios.2006.06.001 · doi:10.1016/j.bios.2006.06.001
  140. Voccia, 2016, Improving impedimetric nucleic acid detection by using enzyme-decorated liposomes and nanostructured screen-printed electrodes, Anal. Bioanal. Chem., 408, 7271, 10.1007/s00216-016-9593-x · doi:10.1007/s00216-016-9593-x
  141. Beitollahi, 2020, Applications of electrochemical sensors and biosensors based on modified screen-printed electrodes: A review, Anal. Methods, 12, 1547, 10.1039/C9AY02598G · DOI
  142. Hannah, S., Dobrea, A., Lasserre, P., Blair, E.O., Alcorn, D., Hoskisson, P.A., and Corrigan, D.K. (2020). Development of a Rapid, Antimicrobial Susceptibility Test for E. coli Based on Low-Cost, Screen-Printed Electrodes. Biosensors, 10. · DOI
  143. Altobelli, 2017, Integrated Biosensor Assay for Rapid Uropathogen Identification and Phenotypic Antimicrobial Susceptibility Testing, Eur. Urol. Focus, 3, 293, 10.1016/j.euf.2015.12.010 · DOI
  144. Zhu, 2018, Immuno-affinity Amperometric Detection of Bacterial Infections, Angew. Chem. Int. Ed., 57, 14942, 10.1002/anie.201808666 · DOI
  145. Mach, 2011, A Biosensor Platform for Rapid Antimicrobial Susceptibility Testing Directly From Clinical Samples, J. Urol., 185, 148, 10.1016/j.juro.2010.09.022 · DOI
  146. Liao, 2006, Use of Electrochemical DNA Biosensors for Rapid Molecular Identification of Uropathogens in Clinical Urine Specimens, J. Clin. Microbiol., 44, 561, 10.1128/JCM.44.2.561-570.2006 · DOI · Paper page
  147. Vu, 2021, A label-free electrochemical biosensor based on screen-printed electrodes modified with gold nanoparticles for quick detection of bacterial pathogens, Mater. Today Commun., 26, 101726, 10.1016/j.mtcomm.2020.101726 · doi:10.1016/j.mtcomm.2020.101726
  148. Shi, 2018, Culture-free bacterial detection and identification from blood with rapid, phenotypic, antibiotic susceptibility testing, Sci. Rep., 8, 3416, 10.1038/s41598-018-21520-9 · DOI
  149. Mascini, 2012, Nucleic acid and peptide aptamers: Fundamentals and bioanalytical aspects, Angew. Chem. Int. Ed., 51, 1316, 10.1002/anie.201006630 · DOI · Paper page
  150. Palchetti, 2012, Electrochemical nanomaterial-based nucleic acid aptasensors, Anal. Bioanal. Chem., 402, 3103, 10.1007/s00216-012-5769-1 · doi:10.1007/s00216-012-5769-1
  151. Hasan, 2018, Carbon nanotube-based aptasensor for sensitive electrochemical detection of whole-cell Salmonella, Anal. Biochem., 554, 34, 10.1016/j.ab.2018.06.001 · doi:10.1016/j.ab.2018.06.001
  152. Muniandy, 2017, Graphene-based label-free electrochemical aptasensor for rapid and sensitive detection of foodborne pathogen, Anal. Bioanal. Chem., 409, 6893, 10.1007/s00216-017-0654-6 · DOI
  153. Jo, 2018, Aptamer-functionalized capacitance sensors for real-time monitoring of bacterial growth and antibiotic susceptibility, Biosens. Bioelectron., 102, 164, 10.1016/j.bios.2017.11.010 · DOI
  154. Fu, 2017, Sensing at the Surface of Graphene Field-Effect Transistors, Adv. Mater., 29, 1603610, 10.1002/adma.201603610 · DOI · Paper page
  155. Ping, 2016, Scalable Production of High-Sensitivity, Label-Free DNA Biosensors Based on Back-Gated Graphene Field Effect Transistors, ACS Nano, 10, 8700, 10.1021/acsnano.6b04110 · DOI · Paper page
  156. Thakur, 2018, Rapid detection of single E. coli bacteria using a graphene-based field-effect transistor device, Biosens. Bioelectron., 110, 16, 10.1016/j.bios.2018.03.014 · DOI
  157. Wu, 2017, Graphene Field-Effect Transistors for the Sensitive and Selective Detection of Escherichia coli Using Pyrene-Tagged DNA Aptamer, Adv. Healthc. Mater., 6, 1700736, 10.1002/adhm.201700736 · DOI
  158. Kumar, 2020, Dielectrophoresis assisted rapid, selective and single cell detection of antibiotic resistant bacteria with G-FETs, Biosens. Bioelectron., 156, 112123, 10.1016/j.bios.2020.112123 · DOI
  159. Ren, 2020, Rapid detection of antibiotic resistance in Salmonella with screen printed carbon electrodes, J. Solid State Electrochem., 24, 1539, 10.1007/s10008-020-04645-8 · DOI
  160. Lee, 2020, Electrical antimicrobial susceptibility testing based on aptamer-functionalized capacitance sensor array for clinical isolates, Sci. Rep., 10, 13709, 10.1038/s41598-020-70459-3 · DOI
  161. Hannah, 2019, Rapid antibiotic susceptibility testing using low-cost, commercially available screen-printed electrodes, Biosens. Bioelectron., 145, 111696, 10.1016/j.bios.2019.111696 · DOI
  162. Mishra, 2019, Rapid antibiotic susceptibility testing by resazurin using thin film platinum as a bio-electrode, J. Microbiol. Methods, 162, 69, 10.1016/j.mimet.2019.05.009 · DOI
  163. Rueda, 2018, A novel inexpensive electrochemical sensor for pyrazinoic acid as a potential tool for the identification of pyrazinamide-resistant Mycobacterium tuberculosis, Int. J. Mycobacteriol., 7, 275, 10.4103/ijmy.ijmy_63_18 · doi:10.4103/ijmy.ijmy_63_18
  164. Sitkov, N.O., Zimina, T.M., and Soloviev, A.V. (February, January 29). Development of impedimetric sensor for E. coli M-17 antibiotic susceptibility testing. Proceedings of the 2018 IEEE Conference of Russian Young Researchers in Electrical and Electronic Engineering (EIConRus), Moscow and St. Petersburg, Russia. · doi:10.1109/eiconrus.2018.8317314
  165. Ibarlucea, 2017, Nanowire sensors monitor bacterial growth kinetics and response to antibiotics, Lab. Chip, 17, 4283, 10.1039/C7LC00807D · DOI
  166. Niyomdecha, 2017, Capacitive antibacterial susceptibility screening test with a simple renewable sensing surface, Biosens. Bioelectron., 96, 84, 10.1016/j.bios.2017.04.042 · doi:10.1016/j.bios.2017.04.042
  167. Safavieh, 2017, Rapid Real-Time Antimicrobial Susceptibility Testing with Electrical Sensing on Plastic Microchips with Printed Electrodes, ACS Appl. Mater. Interfaces, 9, 12832, 10.1021/acsami.6b16571 · DOI
  168. Abeyrathne, 2016, Lab on a chip sensor for rapid detection and antibiotic resistance determination of Staphylococcus aureus, Analyst, 141, 1922, 10.1039/C5AN02301G · DOI
  169. Torok, M.E., Moran, E., and Cooke, F. (2016). Basics of Antimicrobials. Oxford Handbook of Infectious Diseases and Microbiology, Oxford University Press. · doi:10.1093/med/9780199671328.001.0001
  170. Vikesland, 2017, Toward a Comprehensive Strategy to Mitigate Dissemination of Environmental Sources of Antibiotic Resistance, Environ. Sci. Technol., 51, 13061, 10.1021/acs.est.7b03623 · DOI · Paper page
  171. Haddaoui, 2019, E-DNA detection of rpoB gene resistance in Mycobacterium tuberculosis in real samples using Fe3O4/polypyrrole nanocomposite, Biosens. Bioelectron., 128, 76, 10.1016/j.bios.2018.11.045 · DOI
  172. Bizid, 2018, Direct E-DNA sensor of Mycobacterium tuberculosis mutant strain based on new nanocomposite transducer (Fc-ac-OMPA/MWCNTs), Talanta, 184, 475, 10.1016/j.talanta.2018.03.025 · DOI
  173. Rachkov, 2011, Surface plasmon resonance detection of oligonucleotide sequences of the rpoB genes of Mycobacterium tuberculosis, Talanta, 85, 2094, 10.1016/j.talanta.2011.07.032 · doi:10.1016/j.talanta.2011.07.032
  174. Matsishin, 2017, Selective Amplification of SPR Biosensor Signal for Recognition of rpoB Gene Fragments by Use of Gold Nanoparticles Modified by Thiolated DNA, Nanoscale Res. Lett., 12, 252, 10.1186/s11671-017-2031-y · doi:10.1186/s11671-017-2031-y
  175. Hu, 2017, Ultra-fast electronic detection of antimicrobial resistance genes using isothermal amplification and Thin Film Transistor sensors, Biosens. Bioelectron., 96, 281, 10.1016/j.bios.2017.05.016 · DOI
  176. Smith, 2020, A multiplexed, electrochemical interface for gene-circuit-based sensors, Nat. Chem., 12, 48, 10.1038/s41557-019-0366-y · DOI
  177. Wang, 2015, Amplified electrochemical detection of mecA gene in methicillin-resistant Staphylococcus aureus based on target recycling amplification and isothermal strand-displacement polymerization reaction, Sens. Actuators B Chem., 221, 148, 10.1016/j.snb.2015.06.057 · DOI
  178. Huang, 2015, Rapid Electrochemical Detection of New Delhi Metallo-beta-lactamase Genes To Enable Point-of-Care Testing of Carbapenem-Resistant Enterobacteriaceae, Anal. Chem., 87, 7738, 10.1021/acs.analchem.5b01270 · DOI
  179. Maier, 2015, An Impedimetric Sensor for Real-Time Detection of Antibiotic Resistance Genes Employing Rolling Circle Amplification, Int. J. Electrochem. Sci., 10, 2026, 10.1016/S1452-3981(23)04825-3 · doi:10.1016/s1452-3981(23)04825-3
  180. Maldonado, J., González-Guerrero, A.B., Fernández-Gavela, A., González-López, J.J., and Lechuga, L.M. (2020). Ultrasensitive Label-Free Detection of Unamplified Multidrug-Resistance Bacteria Genes with a Bimodal Waveguide Interferometric Biosensor. Diagnostics, 10. · doi:10.3390/diagnostics10100845
  181. Hu, 2019, Identification of Acinetobacter baumannii and its carbapenem-resistant gene blaOXA-23-like by multiple cross displacement amplification combined with lateral flow biosensor, Sci. Rep., 9, 17888, 10.1038/s41598-019-54465-8 · doi:10.1038/s41598-019-54465-8
  182. Lu, 2020, Hairpin-Structured Magnetic SERS Sensor for Tetracycline Resistance Gene tetA Detection, Anal. Chem., 92, 16229, 10.1021/acs.analchem.0c04085 · DOI
  183. Meena, 2020, 7× multiplexed, optofluidic detection of nucleic acids for antibiotic-resistance bacterial screening, Opt. Express, 28, 33019, 10.1364/OE.402311 · DOI
  184. Bizid, 2017, Direct Electrochemical DNA Sensor based on a new redox oligomer modified with ferrocene and carboxylic acid: Application to the detection of Mycobacterium tuberculosis mutant strain, Anal. Chim. Acta, 994, 10, 10.1016/j.aca.2017.09.022 · doi:10.1016/j.aca.2017.09.022
  185. Bengtson, 2017, Multiplex detection of extensively drug resistant tuberculosis using binary deoxyribozyme sensors, Biosens. Bioelectron., 94, 176, 10.1016/j.bios.2017.02.051 · DOI
  186. Zribi, 2016, A microfluidic electrochemical biosensor based on multiwall carbon nanotube/ferrocene for genomic DNA detection of Mycobacterium tuberculosis in clinical isolates, Biomicrofluidics, 10, 14115, 10.1063/1.4940887 · DOI
  187. Liu, 2015, A capacitive DNA sensor-based test for simple and sensitive analysis of antibiotic resistance in field setting, Biosens. Bioelectron., 64, 255, 10.1016/j.bios.2014.08.084 · DOI
  188. Peng, 2015, Label-free electrochemical DNA biosensor for rapid detection of mutidrug resistance gene based on Au nanoparticles/toluidine blue-graphene oxide nanocomposites, Sens. Actuators B Chem., 207, 269, 10.1016/j.snb.2014.10.059 · DOI
  189. Liong, 2013, Magnetic barcode assay for genetic detection of pathogens, Nat. Commun., 4, 1752, 10.1038/ncomms2745 · DOI · Paper page
  190. Bengtson, 2014, A Differential Fluorescent Receptor for Nucleic Acid Analysis, ChemBioChem, 15, 228, 10.1002/cbic.201300657 · DOI
  191. Rachkov, 2013, Discrimination of single base mismatched oligonucleotides related to the rpoB gene of Mycobacterium tuberculosis using a surface plasmon resonance biosensor, Biotechnol. Appl. Biochem., 60, 453, 10.1002/bab.1101 · doi:10.1002/bab.1101
  192. Lam, 2013, Solution-based circuits enable rapid and multiplexed pathogen detection, Nat. Commun., 4, 2001, 10.1038/ncomms3001 · DOI
  193. Strohsahl, C.M., Miller, B.L., and Krauss, T.D. (2008, January 28). Detection of methicillin-resistant Staphylococcus aureus (MRSA) using the NanoLantern Biosensor. Proceedings of the SPIE BiOS, San Jose, CA, USA. · doi:10.1117/12.808872
  194. Koets, 2009, Rapid DNA multi-analyte immunoassay on a magneto-resistance biosensor, Biosens. Bioelectron., 24, 1893, 10.1016/j.bios.2008.09.023 · doi:10.1016/j.bios.2008.09.023
  195. Kara, 2009, Direct electrochemical genosensing for multiple point mutation detection of Mycobacterium tuberculosis during the development of rifampin resistance, Biosens. Bioelectron., 24, 1796, 10.1016/j.bios.2008.08.033 · doi:10.1016/j.bios.2008.08.033
  196. Tombelli, 2006, A DNA-based piezoelectric biosensor: Strategies for coupling nucleic acids to piezoelectric devices, Talanta, 68, 806, 10.1016/j.talanta.2005.06.007 · doi:10.1016/j.talanta.2005.06.007
  197. Choi, 2014, A rapid antimicrobial susceptibility test based on single-cell morphological analysis, Sci. Transl. Med., 6, 267ra174, 10.1126/scitranslmed.3009650 · DOI · Paper page
  198. Metzger, 2014, Rapid simultaneous identification and quantitation of Staphylococcus aureus and Pseudomonas aeruginosa directly from bronchoalveolar lavage specimens using automated microscopy, Diagn. Microbiol. Infect. Dis., 79, 160, 10.1016/j.diagmicrobio.2013.11.029 · doi:10.1016/j.diagmicrobio.2013.11.029
  199. Fredborg, 2013, Real-time optical antimicrobial susceptibility testing, J. Clin. Microbiol., 51, 2047, 10.1128/JCM.00440-13 · DOI

Cited by

See all 70

Metadata

Authors
Reynoso, E. C., Laschi, S., Palchetti, I., & Torres, E.
Venue
Chemosensors
Publisher
MDPI AG
Published
2021-08-19
Volume
9
Issue
8
Pages
232
ISSN
2227-9040
Cited by
70
References
2
Language
en
Funders
  • Consejo Nacional de Ciencia y Tecnología (Grant Number 754592)
  • Regione Toscana (SAFE WATER project (European Uninion’s Horizon 2020 Research&Innovation program and the ERA-NET “PhotonicSensing” cofund- G.A. n. 688735)
  • Fondazione Cassa di Risparmio di Firenze (ID 2020.1662)

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Advances in Antimicrobial Resistance Monitoring Using Sensors and Biosensors: A Review. https://app.cochat.ai/papers/10.3390/chemosensors9080232
The paper
Reynoso, E. C., Laschi, S., Palchetti, I., & Torres, E. (2021). Advances in Antimicrobial Resistance Monitoring Using Sensors and Biosensors: A Review. Chemosensors. https://doi.org/10.3390/chemosensors9080232

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.