Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 113

The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.

The Challenges of Developing Biosensors for Clinical Assessment: A Review

Prabowo, Briliant Adhi, Cabral, Patrícia D., Freitas, Paulo, Fernandes, Elisabete · 2021 · Chemosensors

Published version of a preprint

Abstract

Emerging research in biosensors has attracted much attention worldwide, particularly in response to the recent pandemic outbreak of coronavirus disease 2019 (COVID-19). Nevertheless, initiating research in biosensing applied to the diagnosis of diseases is still challenging for researchers, be it in the preferences of biosensor platforms, selection of biomarkers, detection strategies, or other aspects (e.g., cutoff values) to fulfill the clinical purpose. There are two sides to the development of a diagnostic tool: the biosensor development side and the clinical side. From the development side, the research engineers seek the typical characteristics of a biosensor: sensitivity, selectivity, linearity, stability, and reproducibility. On the other side are the physicians that expect a diagnostic tool that provides fast acquisition of patient information to obtain an early diagnosis or an efficient patient stratification, which consequently allows for making assertive and efficient clinical decisions. The development of diagnostic devices always involves assay developer researchers working as pivots to bridge both sides whose role is to find detection strategies suitable to the clinical needs by understanding (1) the intended use of the technology and its basic principle and (2) the preferable type of test: qualitative or quantitative, sample matrix challenges, biomarker(s) threshold (cutoff value), and if the system requires a mono- or multiplex assay format. This review highlights the challenges for the development of biosensors for clinical assessment and its broad application in multidisciplinary fields. This review paper highlights the following biosensor technologies: magnetoresistive (MR)-based, transistor-based, quartz crystal microbalance (QCM), and optical-based biosensors. Its working mechanisms are discussed with their pros and cons. The article also gives an overview of the most critical parameters that are optimized by developing a diagnostic tool.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.3390/chemosensors9110299

Cites

5 of 5 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 5 references

Research works printed but not linked: 176

  1. Ward, 2020, Novel coronavirus 2019, an emerging public health emergency, Transbound. Emerg. Dis., 67, 469, 10.1111/tbed.13509 · doi:10.1111/tbed.13509
  2. Udugama, 2020, Diagnosing COVID-19: The Disease and Tools for Detection, ACS Nano, 14, 3822, 10.1021/acsnano.0c02624 · DOI · Paper page
  3. Nagel, 2009, Glossary for chemists of terms used in biotechnology (IUPAC Recommendations 1992), Pure Appl. Chem., 64, 143, 10.1351/pac199264010143 · DOI
  4. Puiu, 2020, Microfluidics-integrated biosensing platforms as emergency tools for on-site field detection of foodborne pathogens, TrAC Trends Anal. Chem., 125, 115831, 10.1016/j.trac.2020.115831 · doi:10.1016/j.trac.2020.115831
  5. Selleck, 2017, Making Meaningful Clinical Use of Biomarkers, Biomark. Insights, 12, 1177271917715236, 10.1177/1177271917715236 · DOI · Paper page
  6. Fullerton, 2016, Spintronics, Magnetoresistive Heads, and the Emergence of the Digital World, Proc. IEEE, 104, 1787, 10.1109/JPROC.2016.2567778 · DOI
  7. Wang, 2015, Giant magnetoresistive-based biosensing probe station system for multiplex protein assays, Biosens. Bioelectron., 70, 61, 10.1016/j.bios.2015.03.011 · DOI
  8. Marquina, 2012, GMR sensors and magnetic nanoparticles for immuno-chromatographic assays, J. Magn. Magn. Mater., 324, 3495, 10.1016/j.jmmm.2012.02.074 · DOI
  9. Wu, 2019, Magnetic nanoparticles in nanomedicine: A review of recent advances, Nanotechnology, 30, 502003, 10.1088/1361-6528/ab4241 · DOI · Paper page
  10. Mu, 2019, A new rapid detection method for ricin based on tunneling magnetoresistance biosensor, Sens. Actuators B Chem., 284, 638, 10.1016/j.snb.2018.12.127 · DOI
  11. Kim, 2018, Magnetoresistive biosensors with on-chip pulsed excitation and magnetic correlated double sampling, Sci. Rep., 8, 16493, 10.1038/s41598-018-34720-0 · doi:10.1038/s41598-018-34720-0
  12. Hall, 2010, GMR biosensor arrays: Correction techniques for reproducibility and enhanced sensitivity, Biosens. Bioelectron., 25, 2177, 10.1016/j.bios.2010.01.039 · doi:10.1016/j.bios.2010.01.039
  13. Purwidyantri, A., Tian, Y., Muhammad, G., Saputra, A., and Prabowo, B.A. (2021). Gold Nanoframe Array Electrode for Straightforward Detection of Hydrogen Peroxide. Chemosensors, 9. · DOI
  14. Bhattacharyya, 2019, Specific and label-free immunosensing of protein-protein interactions with silicon-based immunoFETs, Biosens. Bioelectron., 132, 143, 10.1016/j.bios.2019.03.003 · DOI
  15. Danielson, 2020, Graphene based field-effect transistor biosensors functionalized using gas-phase synthesized gold nanoparticles, Sens. Actuators B Chem., 320, 128432, 10.1016/j.snb.2020.128432 · DOI
  16. Kuznetsov, 2019, Integration of a field effect transistor-based aptasensor under a hydrophobic membrane for bioelectronic nose applications, Biosens. Bioelectron., 129, 29, 10.1016/j.bios.2019.01.013 · doi:10.1016/j.bios.2019.01.013
  17. Park, 2020, Interfacial charge regulation of protein blocking layers in transistor biosensor for direct measurement in serum, Biosens. Bioelectron., 147, 111737, 10.1016/j.bios.2019.111737 · doi:10.1016/j.bios.2019.111737
  18. Pletinck, A., Van Biesen, W., Dequidt, C., and Eloot, S. (2018). Transport of neutral IgG2 versus anionic IgG4 in PD: Implications on the electrokinetic model. BMC Nephrol., 19. · doi:10.1186/s12882-018-1104-1
  19. Pillarisetty, 2011, Academic and industry research progress in germanium nanodevices, Nature, 479, 324, 10.1038/nature10678 · doi:10.1038/nature10678
  20. Jing, 2020, Engineering Field Effect Transistors with 2D Semiconducting Channels: Status and Prospects, Adv. Funct. Mater., 30, 1
  21. Jang, 2013, Sensitivity enhancement of amorphous InGaZnO thin film transistor based extended gate field-effect transistors with dual-gate operation, Sens. Actuators B Chem., 181, 880, 10.1016/j.snb.2013.02.056 · DOI · Paper page
  22. Guan, 2014, Highly specific and sensitive non-enzymatic determination of uric acid in serum and urine by extended gate field effect transistor sensors, Biosens. Bioelectron., 51, 225, 10.1016/j.bios.2013.07.061 · DOI
  23. Purwidyantri, 2018, A Colloidal Nanopatterning and Downscaling of a Highly Periodic Au Nanoporous EGFET Biosensor, J. Electrochem. Soc., 165, H3170, 10.1149/2.0241804jes · DOI
  24. 2012, The cell adhesion and cytotoxicity effects of the derivate of vitamin e compared for two cell lines using a piezoelectric biosensor, Sens. Actuators B Chem., 174, 153, 10.1016/j.snb.2012.08.047 · doi:10.1016/j.snb.2012.08.047
  25. Bianco, 2018, Quartz Crystal Microbalance as Cell-Based Biosensor to Detect and Study Cytoskeletal Alterations and Dynamics, Biotechnol. J., 13, 1700699, 10.1002/biot.201700699 · DOI
  26. Xu, 2016, A target-responsive and size-dependent hydrogel aptasensor embedded with QD fluorescent reporters for rapid detection of avian influenza virus H5N1, Sens. Actuators B Chem., 234, 98, 10.1016/j.snb.2016.04.156 · DOI
  27. Jean, 2020, Quartz crystal microbalance-based biosensors as rapid diagnostic devices for infectious diseases, Biosens. Bioelectron., 168, 112513, 10.1016/j.bios.2020.112513 · DOI · Paper page
  28. Fu, 2017, Advances in piezoelectric thin films for acoustic biosensors, acoustofluidics and lab-on-chip applications, Prog. Mater. Sci., 89, 31, 10.1016/j.pmatsci.2017.04.006 · DOI · Paper page
  29. Prabowo, B.A., Purwidyantri, A., and Liu, K.-C.C. (2018). Surface Plasmon Resonance Optical Sensor: A Review on Light Source Technology. Biosensors, 8. · DOI
  30. Long, Y.-T., and Jing, C. (2014). Localized Surface Plasmon Resonance based Nanobiosensors., Springer. · doi:10.1007/978-3-642-54795-9
  31. Szunerits, 2014, Surface plasmon resonance: Signal amplification using colloidal gold nanoparticles for enhanced sensitivity, Rev. Anal. Chem., 33, 153, 10.1515/revac-2014-0011 · DOI
  32. Lin, H.T.-H., Yang, C.-K., Lin, C.-C., Wu, A.M.-H., Wang, L.A., and Huang, N.-T. (2017). A Large-Area Nanoplasmonic Sensor Fabricated by Rapid Thermal Annealing Treatment for Label-Free and Multi-Point Immunoglobulin Sensing. Nanomaterials, 7. · doi:10.3390/nano7050100
  33. Adegoke, 2017, Localized surface plasmon resonance-mediated fluorescence signals in plasmonic nanoparticle-quantum dot hybrids for ultrasensitive Zika virus RNA detection via hairpin hybridization assays, Biosens. Bioelectron., 94, 513, 10.1016/j.bios.2017.03.046 · doi:10.1016/j.bios.2017.03.046
  34. Gupta, 2020, ZnO-Nanorod processed PC-SET as the light-harvesting model for plasmontronic fluorescence Sensor, Sens. Actuators B Chem., 307, 127597, 10.1016/j.snb.2019.127597 · doi:10.1016/j.snb.2019.127597
  35. Su, 2019, Two-dimensional nanomaterials for biosensing applications, TrAC Trends Anal. Chem., 119, 115610, 10.1016/j.trac.2019.07.021 · DOI · Paper page
  36. Wang, 2010, Nanomaterial-assisted aptamers for optical sensing, Biosens. Bioelectron., 25, 1859, 10.1016/j.bios.2009.11.012 · doi:10.1016/j.bios.2009.11.012
  37. Prabowo, 2021, Gold nanoparticle-assisted plasmonic enhancement for DNA detection on a graphene-based portable surface plasmon resonance sensor, Nanotechnology, 32, 095503, 10.1088/1361-6528/abcd62 · doi:10.1088/1361-6528/abcd62
  38. Rossi, 2014, Biosensor analysis of anti-citrullinated protein/peptide antibody affinity, Anal. Biochem., 465C, 96, 10.1016/j.ab.2014.07.030 · doi:10.1016/j.ab.2014.07.030
  39. Gopinath, 2010, Biosensing applications of surface plasmon resonance-based Biacore technology, Sens. Actuators B, 150, 722, 10.1016/j.snb.2010.08.014 · DOI
  40. Guner, 2017, A smartphone based surface plasmon resonance imaging (SPRi) platform for on-site biodetection, Sens. Actuators B Chem., 239, 571, 10.1016/j.snb.2016.08.061 · DOI · Paper page
  41. Wuytens, 2017, On-chip surface-enhanced Raman spectroscopy using nanosphere-lithography patterned antennas on silicon nitride waveguides, Opt. Express, 25, 12926, 10.1364/OE.25.012926 · DOI
  42. Anker, 2008, Biosensing with plasmonic nanosensors, Nat. Mater., 7, 442, 10.1038/nmat2162 · DOI · Paper page
  43. Zheng, 2017, Semiconductor SERS enhancement enabled by oxygen incorporation, Nat. Commun., 8, 1993, 10.1038/s41467-017-02166-z · DOI · Paper page
  44. Purwidyantri, 2019, Plasmonic nanomaterial structuring for SERS enhancement, RSC Adv., 9, 4982, 10.1039/C8RA10656H · DOI
  45. Tang, 2018, Cellular imaging by targeted assembly of hot-spot SERS and photoacoustic nanoprobes using split-fluorescent protein scaffolds, Nat. Commun., 9, 607, 10.1038/s41467-018-03046-w · DOI
  46. Gong, 2015, Highly sensitive SERS detection and quantification of sialic acid on single cell using photonic-crystal fiber with gold nanoparticles, Biosens. Bioelectron., 64, 227, 10.1016/j.bios.2014.08.077 · DOI
  47. Kang, 2015, Repeated Solid-state Dewetting of Thin Gold Films for Nanogap-rich Plasmonic Nanoislands, Sci. Rep., 5, 14790, 10.1038/srep14790 · DOI
  48. Kim, 2018, Low-cost, high-performance plasmonic nanocomposites for hazardous chemical detection using surface enhanced Raman scattering, Sens. Actuators B Chem., 274, 30, 10.1016/j.snb.2018.07.107 · DOI
  49. Yang, 2015, Ultrasensitive surface-enhanced Raman scattering detection in common fluids, Proc. Natl. Acad. Sci. USA, 113, 268, 10.1073/pnas.1518980113 · DOI · Paper page
  50. Zhang, 2017, A metallic molybdenum dioxide with high stability for surface enhanced Raman spectroscopy, Nat. Commun., 8, 14903, 10.1038/ncomms14903 · DOI · Paper page
  51. Liu, 2019, Low fouling strategies for electrochemical biosensors targeting disease biomarkers, Anal. Methods, 11, 702, 10.1039/C8AY02674B · DOI
  52. Liu, 2016, Design and mechanisms of antifouling materials for surface plasmon resonance sensors, Acta Biomater., 40, 100, 10.1016/j.actbio.2016.02.035 · DOI
  53. Qian, 2019, Fiber optic surface plasmon resonance biosensor for detection of PDGF-BB in serum based on self-assembled aptamer and antifouling peptide monolayer, Biosens. Bioelectron., 140, 111350, 10.1016/j.bios.2019.111350 · doi:10.1016/j.bios.2019.111350
  54. Zhang, 2014, Amplified amperometric aptasensor for selective detection of protein using catalase-functional DNA-PtNPs dendrimer as a synergetic signal amplification label, Biosens. Bioelectron., 60, 224, 10.1016/j.bios.2014.04.024 · doi:10.1016/j.bios.2014.04.024
  55. Park, 2014, An ultra-sensitive detection of a whole virus using dual aptamers developed by immobilization-free screening, Biosens. Bioelectron., 51, 324, 10.1016/j.bios.2013.07.052 · doi:10.1016/j.bios.2013.07.052
  56. Chang, 2013, Using a fiber optic particle plasmon resonance biosensor to determine kinetic constants of antigen-antibody binding reaction, Anal. Chem., 85, 245, 10.1021/ac302590n · DOI
  57. Ali, 2012, Cell-surface sensors: Lighting the cellular environment, Wiley Interdiscip. Rev. Nanomed. Nanobiotechnol., 4, 547, 10.1002/wnan.1179 · DOI
  58. Chen, 2017, Field-effect transistor biosensors with two-dimensional black phosphorus nanosheets, Biosens. Bioelectron., 89, 505, 10.1016/j.bios.2016.03.059 · doi:10.1016/j.bios.2016.03.059
  59. Naylor, 2016, Scalable Production of Molybdenum Disul fi de Based Biosensors, ACS Nano, 10, 6173, 10.1021/acsnano.6b02137 · DOI
  60. Mao, 2017, Two-dimensional nanomaterial-based field-effect transistors for chemical and biological sensing, Chem. Soc. Rev., 46, 6872, 10.1039/C6CS00827E · DOI · Paper page
  61. Comini, 2009, Quasi-one dimensional metal oxide semiconductors: Preparation, characterization and application as chemical sensors, Prog. Mater. Sci., 54, 1, 10.1016/j.pmatsci.2008.06.003 · DOI · Paper page
  62. Ramnani, 2016, Carbon nanomaterial-based electrochemical biosensors for label-free sensing of environmental pollutants, Chemosphere, 143, 85, 10.1016/j.chemosphere.2015.04.063 · DOI · Paper page
  63. Afsahi, 2018, Novel graphene-based biosensor for early detection of Zika virus infection, Biosens. Bioelectron., 100, 85, 10.1016/j.bios.2017.08.051 · doi:10.1016/j.bios.2017.08.051
  64. Xu, 2014, Electrophoretic and field-effect graphene for all-electrical DNA array technology, Nat. Commun., 5, 4866, 10.1038/ncomms5866 · DOI
  65. Mao, 2010, Specific protein detection using thermally reduced graphene oxide sheet decorated with gold nanoparticle-antibody conjugates, Adv. Mater., 22, 3521, 10.1002/adma.201000520 · DOI · Paper page
  66. Purwidyantri, A., Domingues, T., Guerreiro, J.R., Ipatov, A., Abreu, C.M., Martins, M., Alpuim, P., and Prado, M. (2021). Influence of the Electrolyte Salt Concentration on DNA Detection with Graphene Transistors. Biosensors, 11. · DOI
  67. Sarkar, 2014, MoS2 field-effect transistor for next-generation label-free biosensors, ACS Nano, 8, 3992, 10.1021/nn5009148 · DOI · Paper page
  68. Lee, 2015, Field-effect transistor with a chemically synthesized MoS2 sensing channel for label-free and highly sensitive electrical detection of DNA hybridization, Nano Res., 8, 2340, 10.1007/s12274-015-0744-8 · DOI
  69. Wang, 2020, Competitive electrochemical aptasensor based on a cDNA-ferrocene/MXene probe for detection of breast cancer marker Mucin1, Anal. Chim. Acta, 1094, 18, 10.1016/j.aca.2019.10.003 · DOI · Paper page
  70. Lim, 2013, A peptide receptor-based bioelectronic nose for the real-time determination of seafood quality, Biosens. Bioelectron., 39, 244, 10.1016/j.bios.2012.07.054 · DOI
  71. Lee, 2010, Low-cost, transparent, and flexible single-walled carbon nanotube nanocomposite based ion-sensitive field-effect transistors for pH/glucose sensing, Biosens. Bioelectron., 25, 2259, 10.1016/j.bios.2010.03.003 · DOI
  72. Park, 2014, Human dopamine receptor nanovesicles for gate-potential modulators in high-performance field-effect transistor biosensors, Sci. Rep., 4, 4342, 10.1038/srep04342 · DOI
  73. Jun, 2014, Aptamer-Functionalized Hybrid Carbon Nano fi ber FET-Type Electrode for a Highly Sensitive and Selective Platelet-Derived Growth Factor Biosensor, Appl. Mater. Interface, 6, 13859, 10.1021/am5032693 · DOI
  74. Chen, 2017, High-sensitivity and large-dynamic-range refractive index sensors employing weak composite Fabry-Perot cavities, Opt. Lett., 42, 3145, 10.1364/OL.42.003145 · doi:10.1364/ol.42.003145
  75. Prabowo, 2019, Nano-film aluminum-gold for ultra-high dynamic-range surface plasmon resonance chemical sensor, Front. Optoelectron., 12, 286, 10.1007/s12200-019-0864-y · doi:10.1007/s12200-019-0864-y
  76. Chou, 2016, Ultra-low fouling and high antibody loading zwitterionic hydrogel coatings for sensing and detection in complex media, Acta Biomater., 40, 31, 10.1016/j.actbio.2016.04.023 · DOI
  77. Singha, 2018, Au nanoparticles functionalized 3D-MoS2 nanoflower: An efficient SERS matrix for biomolecule sensing, Biosens. Bioelectron., 119, 10, 10.1016/j.bios.2018.07.061 · DOI
  78. Purwidyantri, 2017, Speckled ZnO Nanograss Electrochemical Sensor for Staphylococcus epidermidis Detection, J. Electrochem. Soc., 164, B205, 10.1149/2.0811706jes · doi:10.1149/2.0811706jes
  79. Prabowo, B.A. (2019, January 23–24). The Trade-Off Performance of Surface Plasmon Resonance Sensing Utilizing Thin Layer Oxide under the Metal Layer. Proceedings of the 2019 International Conference on Radar, Antenna, Microwave, Electronics, and Telecommunications (ICRAMET), Serpong, Indonesia. · doi:10.1109/icramet47453.2019.8980455
  80. Fernandes, 2020, Point-of-care quantification of serum cellular fibronectin levels for stratification of ischemic stroke patients, Nanomed. Nanotechnol. Biol. Med., 30, 102287, 10.1016/j.nano.2020.102287 · doi:10.1016/j.nano.2020.102287
  81. Kamat, 2017, Designing binding kinetic assay on the bio-layer interferometry (BLI) biosensor to characterize antibody-antigen interactions, Anal. Biochem., 536, 16, 10.1016/j.ab.2017.08.002 · DOI
  82. Sharma, 2016, Antibodies and antibody-derived analytical biosensors, Essays Biochem., 60, 9, 10.1042/EBC20150002 · DOI · Paper page
  83. Long, 1983, Limit of Detection a Closer Look at the IUPAC Definition, Anal. Chem., 55, 712A
  84. Currie, 1999, Nomenclature in evaluation of analytical methods including detection and quantification capabilities. Adapted from the International Union of Pure and Applied Chemistry (IUPAC) document “Nomenclature in Evaluation of Analytical Methods including Detection, Anal. Chim. Acta, 391, 105, 10.1016/S0003-2670(99)00104-X · DOI
  85. Stroot, 2012, Capture antibody targeted fluorescence in situ hybridization (CAT-FISH): Dual labeling allows for increased specificity in complex samples, J. Microbiol. Methods, 88, 275, 10.1016/j.mimet.2011.12.009 · doi:10.1016/j.mimet.2011.12.009
  86. Duman, 2010, Detection of Mycobacterium tuberculosis complex and Mycobacterium gordonae on the same portable surface plasmon resonance sensor, Biosens. Bioelectron., 26, 908, 10.1016/j.bios.2010.06.071 · doi:10.1016/j.bios.2010.06.071
  87. Chauhan, 2020, Nanostructured transition metal chalcogenide embedded on reduced graphene oxide based highly efficient biosensor for cardiovascular disease detection, Microchem. J., 155, 104697, 10.1016/j.microc.2020.104697 · doi:10.1016/j.microc.2020.104697
  88. Deng, 2013, An aptamer-based biosensing platform for highly sensitive detection of platelet-derived growth factor via enzyme-mediated direct electrochemistry, Anal. Chim. Acta, 759, 61, 10.1016/j.aca.2012.11.018 · doi:10.1016/j.aca.2012.11.018
  89. Xie, 2018, Simultaneous detection of Dengue and Zika virus RNA sequences with a three-dimensional Cu-based zwitterionic metal–organic framework, comparison of single and synchronous fluorescence analysis, Sens. Actuators B Chem., 254, 1133, 10.1016/j.snb.2017.06.085 · doi:10.1016/j.snb.2017.06.085
  90. Sin, 2014, Hemocompatibility of zwitterionic interfaces and membranes, Polym. J., 46, 436, 10.1038/pj.2014.46 · DOI · Paper page
  91. Chen, 2014, Synthesis and characterization of antifouling poly(N-acryloylaminoethoxyethanol) with ultralow protein adsorption and cell attachment, Langmuir, 30, 10398, 10.1021/la502136q · DOI
  92. Riedel, 2014, Diagnosis of Epstein-Barr virus infection in clinical serum samples by an SPR biosensor assay, Biosens. Bioelectron., 55, 278, 10.1016/j.bios.2013.12.011 · doi:10.1016/j.bios.2013.12.011
  93. Homola, 2012, Biofunctionalized gold nanoparticles for SPR-biosensor-based detection of CEA in blood plasma, Anal. Bioanal. Chem., 404, 2869, 10.1007/s00216-012-6308-9 · doi:10.1007/s00216-012-6308-9
  94. Liu, G., Gurung, A.S., and Qiu, W. (2019). Lateral flow aptasensor for simultaneous detection of platelet-derived growth factor-BB (PDGF-BB) and thrombin. Molecules, 24. · doi:10.3390/molecules24040756
  95. Chen, 2018, Ultrasensitive photoelectrochemical immunosensor of cardiac troponin I detection based on dual inhibition effect of Ag@Cu2O core-shell submicron-particles on CdS QDs sensitized TiO2 nanosheets, Biosens. Bioelectron., 117, 340, 10.1016/j.bios.2018.05.037 · doi:10.1016/j.bios.2018.05.037
  96. Averseng, 2010, Surface plasmon resonance for rapid screening of uranyl affine proteins, Anal. Chem., 82, 9797, 10.1021/ac102578y · doi:10.1021/ac102578y
  97. Bartlett, 2008, Reliability, repeatability and reproducibility: Analysis of measurement errors in continuous variables, Ultrasound Obstet. Gynecol., 31, 466, 10.1002/uog.5256 · DOI · Paper page
  98. Cipriani, 2020, Increased circulating levels of Factor H-Related Protein 4 are strongly associated with age-related macular degeneration, Nat. Commun., 11, 778, 10.1038/s41467-020-14499-3 · DOI
  99. Gu, 2018, SERS Sensors: Recent Developments and a Generalized Classification Scheme Based on the Signal Origin, Annu. Rev. Anal. Chem., 11, 147, 10.1146/annurev-anchem-061417-125724 · DOI
  100. Prabowo, 2018, Rapid screening of Mycobacterium tuberculosis complex (MTBC) in clinical samples by a modular portable biosensor, Sens. Actuators B Chem., 254, 742, 10.1016/j.snb.2017.07.102 · doi:10.1016/j.snb.2017.07.102
  101. Prabowo, 2017, Rapid detection and quantification of Enterovirus 71 by a portable surface plasmon resonance biosensor, Biosens. Bioelectron., 92, 186, 10.1016/j.bios.2017.01.043 · doi:10.1016/j.bios.2017.01.043
  102. Chen, 2012, Study on the performance promotion of the surface plasmon resonance analytical system, Instrum. Sci. Technol., 40, 226, 10.1080/10739149.2011.651672 · doi:10.1080/10739149.2011.651672
  103. Wang, 2012, Without-baseline centroid algorithm for surface plasmon resonance spectra, Chin. J. Sens. Actuators, 25, 365
  104. Dong, 2007, High-sensitivity, large dynamic range, auto-calibration methane optical sensor using a short confocal Fabry-Perot cavity, Sens. Actuators B Chem., 127, 350, 10.1016/j.snb.2007.04.030 · doi:10.1016/j.snb.2007.04.030
  105. Atkinson, 2001, Biomarkers and surrogate endpoints: Preferred definitions and conceptual framework, Clin. Pharmacol. Ther., 69, 89, 10.1067/mcp.2001.113989 · DOI · Paper page
  106. Moroncini, 2017, Characterization of binding and quantification of human autoantibodies to PDGFRα using a biosensor-based approach, Anal. Biochem., 528, 26, 10.1016/j.ab.2017.04.011 · DOI
  107. Yakhno, 2007, Uncoated quartz resonator as a universal biosensor, Biosens. Bioelectron., 22, 2127, 10.1016/j.bios.2006.09.029 · DOI
  108. Babaki, 2017, Antigen 85 complex as a powerful Mycobacterium tuberculosis immunogene: Biology, immune-pathogenicity, applications in diagnosis, and vaccine design, Microb. Pathog., 112, 20, 10.1016/j.micpath.2017.08.040 · DOI
  109. Sobrino, 2013, Prometalloproteinase-10 is associated with brain damage and clinical outcome in acute ischemic stroke, J. Thromb. Haemost., 11, 1464, 10.1111/jth.12312 · DOI
  110. Hamzeiy, 2014, Nanoscaled aptasensors for multi-analyte sensing, BioImpacts, 4, 205
  111. Sefah, 2009, Nucleic acid aptamers for biosensors and bio-analytical applications, Analyst, 134, 1765, 10.1039/b905609m · DOI · Paper page
  112. Oyejide, L., Mendes, O.R., and Mikaelian, I. (2017). Molecular Pathology: Applications in Nonclinical Drug Development. A Comprehensive Guide to Toxicology in Nonclinical Drug Development, Elsevier Inc. · DOI
  113. Lee, 2019, Circulating biomarkers predictive of tumor response to cancer immunotherapy, Expert Rev. Mol. Diagn., 19, 895, 10.1080/14737159.2019.1659728 · DOI
  114. Sobrino, 2011, Early biomarkers of clinical-diffusion mismatch in acute ischemic stroke, Stroke, 42, 2813, 10.1161/STROKEAHA.111.614503 · doi:10.1161/strokeaha.111.614503
  115. Shaqdan, 2014, Incidence of contrast medium extravasation for CT and MRI in a large academic medical centre: A report on 502,391 injections, Clin. Radiol., 69, 1264, 10.1016/j.crad.2014.08.004 · doi:10.1016/j.crad.2014.08.004
  116. Seher, 2011, Gene expression profiling of connective tissue growth factor (CTGF) stimulated primary human tenon fibroblasts reveals an inflammatory and wound healing response in vitro, Mol. Vis., 17, 53
  117. Green, 2015, Interactions of DNA with graphene and sensing applications of graphene field-effect transistor devices: A review, Anal. Chim. Acta, 853, 127, 10.1016/j.aca.2014.10.023 · DOI
  118. Yu, 2017, Proximity hybridization-mediated isothermal exponential amplification for ultrasensitive electrochemical protein detection, Int. J. Nanomed., 12, 5903, 10.2147/IJN.S142015 · DOI
  119. Razmi, 2018, Recent advances on aptamer-based biosensors to detection of platelet-derived growth factor, Biosens. Bioelectron., 113, 58, 10.1016/j.bios.2018.04.048 · doi:10.1016/j.bios.2018.04.048
  120. Hong, 2017, Portable aptamer biosensor of platelet-derived growth factor-BB using a personal glucose meter with triply amplified, Biosens. Bioelectron., 95, 152, 10.1016/j.bios.2017.04.023 · DOI
  121. Sameiyan, 2019, DNA origami-based aptasensors, Biosens. Bioelectron., 143, 111662, 10.1016/j.bios.2019.111662 · DOI
  122. Bagheri, 2018, Triple-helix molecular switch-based aptasensors and DNA sensors, Biosens. Bioelectron., 111, 1, 10.1016/j.bios.2018.03.070 · DOI
  123. Gilgunn, 2013, Aberrant PSA glycosylation—A sweet predictor of prostate cancer, Nat. Rev. Urol., 10, 99, 10.1038/nrurol.2012.258 · DOI · Paper page
  124. Tzouvadaki, 2016, Label-free ultrasensitive memristive aptasensor, Nano Lett., 16, 4472, 10.1021/acs.nanolett.6b01648 · DOI
  125. Yang, 2017, A novel SERS-based magnetic aptasensor for prostate specific antigen assay with high sensitivity, Biosens. Bioelectron., 94, 286, 10.1016/j.bios.2017.02.048 · DOI
  126. Su, 2013, Detection of cancer biomarkers by piezoelectric biosensor using PZT ceramic resonator as the transducer, Biosens. Bioelectron., 46, 155, 10.1016/j.bios.2013.01.074 · doi:10.1016/j.bios.2013.01.074
  127. Su, 2010, Detection of prostate-specific antigen with a paired surface plasma wave biosensor, Anal. Chem., 82, 3714, 10.1021/ac100071h · doi:10.1021/ac100071h
  128. Cao, 2006, A strategy for sensitivity and specificity enhancements in prostate specific antigen-alpha(1)-antichymotrypsin detection based on surface plasmon resonance, Biosens. Bioelectron., 21, 2106, 10.1016/j.bios.2005.10.014 · doi:10.1016/j.bios.2005.10.014
  129. Sisinni, 2015, The Role of Human Chorionic Gonadotropin as Tumor Marker: Biochemical and Clinical Aspects, Adv. Exp. Med. Biol., 867, 229, 10.1007/978-94-017-7215-0_14 · doi:10.1007/978-94-017-7215-0_14
  130. Liu, 2013, Multiplexed immunoassay biosensor for the detection of serum biomarkers - β-HCG and AFP of Down Syndrome based on photoluminescent water-soluble CdSe/ZnS quantum dots, Sens. Actuators B Chem., 186, 235, 10.1016/j.snb.2013.05.094 · doi:10.1016/j.snb.2013.05.094
  131. Matsui, 2003, Criteria for Initiating Chemotherapy in Patients after Evacuation of Hydatidiform Mole, Tumor Biol., 24, 140, 10.1159/000073843 · doi:10.1159/000073843
  132. Lei, H., Wang, K., Ji, X., and Cui, D. (2016). Contactless measurement of magnetic nanoparticles on lateral flow strips using tunneling magnetoresistance (TMR) sensors in differential configuration. Sensors (Switzerland), 16. · DOI
  133. Khodadadi, M., Chang, L., Trabuco, J.R.C., Vu, B.V., Kourentzi, K., Willson, R.C., and Litvinov, D. (2019). PCB-based magnetometer as a platform for quantification of lateral-flow assays. Sensors (Switzerland), 19. · doi:10.3390/s19245433
  134. Yan, 2019, Machine Learning Approach to Enhance the Performance of MNP-Labeled Lateral Flow Immunoassay, Nano-Micro Lett., 11, 7, 10.1007/s40820-019-0239-3 · DOI
  135. Piliarik, 2010, Real-time monitoring of biomolecular interactions in blood plasma using a surface plasmon resonance biosensor, Anal. Bioanal. Chem., 398, 1955, 10.1007/s00216-010-4159-9 · doi:10.1007/s00216-010-4159-9
  136. Chang, 2014, Colorimetric detection of human chorionic gonadotropin using catalytic gold nanoparticles and a peptide aptamer, Chem. Commun., 50, 14443, 10.1039/C4CC06366J · DOI
  137. Chung, 2012, Human chorionic gonadotropin interactions with immobilized anti-hCG studied by quartz-crystal microbalance with dissipation monitoring, J. Biomed. Mater. Res. -Part A, 100A, 1600, 10.1002/jbm.a.34100 · doi:10.1002/jbm.a.34100
  138. Liao, 2019, Electrical Double Layer Gated Field Effect Transistor Biosensors for the Quantitative Detection of Beta-Human Chorionic Gonadotropin, ECS Trans., 92, 57, 10.1149/09206.0057ecst · doi:10.1149/09206.0057ecst
  139. Wu, 2009, Specificity of a High-Sensitivity Cardiac Troponin I Assay Using Single-Molecule–Counting Technology, Clin. Chem., 55, 196, 10.1373/clinchem.2008.108837 · doi:10.1373/clinchem.2008.108837
  140. Kavsak, 2009, Short- and long-term risk stratification using a next-generation, high-sensitivity research cardiac troponin I (hs-cTnI) assay in an Emergency Department Chest Pain Population, Clin. Chem., 55, 1809, 10.1373/clinchem.2009.127241 · doi:10.1373/clinchem.2009.127241
  141. Liu, 2020, A microfabricated thickness shear mode electroacoustic resonator for the label-free detection of cardiac troponin in serum, Talanta, 215, 120890, 10.1016/j.talanta.2020.120890 · DOI
  142. Patra, 2017, Using extraordinary optical transmission to quantify cardiac biomarkers in human serum, J. Vis. Exp., 2017, 55597
  143. Krupin, O., and Berini, P. (2019). Long-range surface plasmon-polariton waveguide biosensors for human cardiac troponin I detection. Sensors (Switzerland), 19. · DOI
  144. Han, 2018, Ultrasensitive Plasmonic Biosensors for Real-Time Parallel Detection of Alpha-L-Fucosidase and Cardiac-Troponin-I in Whole Human Blood, Anal. Chem., 90, 7795, 10.1021/acs.analchem.8b01816 · DOI
  145. Wu, 2017, Ultrasensitive magnetic field-assisted surface plasmon resonance immunoassay for human cardiac troponin I, Biosens. Bioelectron., 96, 288, 10.1016/j.bios.2017.05.023 · DOI
  146. Liyanage, 2017, Achieving biosensing at attomolar concentrations of cardiac troponin T in human biofluids by developing a label-free nanoplasmonic analytical assay, Analyst, 142, 2442, 10.1039/C7AN00430C · doi:10.1039/c7an00430c
  147. Wu, 2017, Hollow gold nanoparticle-enhanced SPR based sandwich immunoassay for human cardiac troponin I, Microchim. Acta, 184, 2395, 10.1007/s00604-017-2245-9 · DOI
  148. Sarangadharan, 2018, Single Drop Whole Blood Diagnostics: Portable Biomedical Sensor for Cardiac Troponin i Detection, Anal. Chem., 90, 2867, 10.1021/acs.analchem.7b05018 · DOI
  149. Sarangadharan, 2018, High sensitivity cardiac troponin I detection in physiological environment using AlGaN/GaN High Electron Mobility Transistor (HEMT) Biosensors, Biosens. Bioelectron., 100, 282, 10.1016/j.bios.2017.09.018 · DOI · Paper page
  150. Sarangadharan, 2018, Whole blood cvd diagnostics using portable fet biosensor system, ECS Trans., 85, 25, 10.1149/08509.0025ecst · doi:10.1149/08509.0025ecst
  151. Huang, 2019, Study of stability and sensitivity of cardiac troponin I based on FET sensor, ECS Trans., 89, 57, 10.1149/08906.0057ecst · doi:10.1149/08906.0057ecst
  152. Cai, 2015, Gold nanoparticles-decorated graphene field-effect transistor biosensor for femtomolar MicroRNA detection, Biosens. Bioelectron., 74, 329, 10.1016/j.bios.2015.06.068 · DOI · Paper page
  153. Duffy, 2020, Biomarkers for prostate cancer: Prostate-specific antigen and beyond, Clin. Chem. Lab. Med., 58, 326, 10.1515/cclm-2019-0693 · DOI · Paper page
  154. Marinca, 2019, KRAS, NRAS, BRAF, HER2 and microsatellite instability in metastatic colorectal cancer-practical implications for the clinician, Radiol. Oncol., 53, 265, 10.2478/raon-2019-0033 · DOI · Paper page
  155. Muinao, 2019, Multi-biomarker panel signature as the key to diagnosis of ovarian cancer, Heliyon, 5, e02826, 10.1016/j.heliyon.2019.e02826 · DOI
  156. Katchman, 2016, Application of flat panel OLED display technology for the point-of-care detection of circulating cancer biomarkers, Sci. Rep., 6, 29057, 10.1038/srep29057 · DOI
  157. Qureshi, 2010, Label-free capacitive biosensor for sensitive detection of multiple biomarkers using gold interdigitated capacitor arrays, Biosens. Bioelectron., 25, 2318, 10.1016/j.bios.2010.03.018 · doi:10.1016/j.bios.2010.03.018
  158. Muthukumar, 2017, Ultrasensitive nanostructure sensor arrays on flexible substrates for multiplexed and simultaneous electrochemical detection of a panel of cardiac biomarkers, Biosens. Bioelectron., 89, 764, 10.1016/j.bios.2016.10.046 · DOI
  159. Issadore, 2012, Ultrasensitive clinical enumeration of rare cells ex vivo using a micro-hall detector, Sci. Transl. Med., 4, 141ra92, 10.1126/scitranslmed.3003747 · DOI · Paper page
  160. Ewald, 2020, A multi-analyte biosensor for the simultaneous label-free detection of pathogens and biomarkers in point-of-need animal testing, Anal. Bioanal. Chem., 407, 4005, 10.1007/s00216-015-8562-0 · doi:10.1007/s00216-015-8562-0
  161. Fountoglou, 2016, Two-panel molecular testing for genetic predisposition for thrombosis using multi-allele visual biosensors, Anal. Bioanal. Chem., 408, 1943, 10.1007/s00216-016-9310-9 · doi:10.1007/s00216-016-9310-9
  162. Lee, 2015, A nanoplasmonic biosensor for label-free multiplex detection of cancer biomarkers, Biosens. Bioelectron., 74, 341, 10.1016/j.bios.2015.06.059 · DOI
  163. Jiang, 2017, Aptamer/AuNP Biosensor for Colorimetric Profiling of Exosomal Proteins, Angew. Chem. -Int. Ed., 56, 11916, 10.1002/anie.201703807 · DOI · Paper page
  164. Wang, Y.Y., Yuan, W., Zhang, Q., Wang, Y.Y., Kimber, M., Dong, L., and Lu, M. Exosome microarray based on label-free imaging biosensor. Proceedings of the IEEE Sensors.
  165. Prasad, 2017, Companion and Point-of-Care Sensor System for Rapid Multiplexed Detection of a Panel of Infectious Disease Markers, SLAS Technol. Transl. Life Sci. Innov., 22, 338
  166. Felder, 2014, MUC16 (CA125): Tumor biomarker to cancer therapy, a work in progress, Mol. Cancer, 13, 129, 10.1186/1476-4598-13-129 · DOI · Paper page
  167. Skates, 1995, Toward an optimal algorithm for ovarian cancer screening with longitudinal tumor markers, Cancer, 76, 2004, 10.1002/1097-0142(19951115)76:10+<2004::AID-CNCR2820761317>3.0.CO;2-G · doi:10.1002/1097-0142(19951115)76:10+<2004::aid-cncr2820761317>3.0.co;2-g
  168. Fakanya, 2014, Detection of the inflammation biomarker C-reactive protein in serum samples: Towards an optimal biosensor formula, Biosensors, 4, 340, 10.3390/bios4040340 · DOI
  169. Ling, 2020, C-reactive protein levels in the early stage of COVID-19, Médecine Mal. Infect., 50, 332, 10.1016/j.medmal.2020.03.007 · DOI · Paper page
  170. Blanco, 2012, Update on the research of serum biomarkers to assess stroke, Drugs Future, 37, 283, 10.1358/dof.2012.37.4.1769799 · doi:10.1358/dof.2012.37.4.1769799
  171. Jickling, 2011, Blood Biomarkers of Ischemic Stroke, Neurotherapeutics, 8, 349, 10.1007/s13311-011-0050-4 · DOI · Paper page
  172. Maestrini, 2016, Blood biomarkers in the early stage of cerebral ischemia, Rev. Neurol. (Paris), 172, 198, 10.1016/j.neurol.2016.02.003 · DOI
  173. Blanco, 2013, Platelet derived growth factor-CC isoform is associated with hemorrhagic transformation in ischemic stroke patients treated with tissue plasminogen activator, Atherosclerosis, 226, 165, 10.1016/j.atherosclerosis.2012.10.072 · doi:10.1016/j.atherosclerosis.2012.10.072
  174. Sobrino, 2011, Association between neuroserpin and molecular markers of brain damage in patients with acute ischemic stroke, J. Transl. Med., 9, 58, 10.1186/1479-5876-9-58 · doi:10.1186/1479-5876-9-58
  175. Foerch, 2007, Elevated serum S100B levels indicate a higher risk of hemorrhagic transformation after thrombolytic therapy in acute stroke, Stroke, 38, 2491, 10.1161/STROKEAHA.106.480111 · DOI
  176. Wood, 2011, Development and validation of a multiplex microsphere-based assay for detection of domestic cat (Felis catus) cytokines, Clin. Vaccine Immunol., 18, 387, 10.1128/CVI.00289-10 · doi:10.1128/cvi.00289-10

Cited by

Metadata

Authors
Prabowo, B. A., Cabral, P. D., Freitas, P., & Fernandes, E.
Venue
Chemosensors
Publisher
MDPI AG
Published
2021-10-24
Volume
9
Issue
11
Pages
299
ISSN
2227-9040
Cited by
113
References
5
Language
en
Funders
Fundação para a Ciência e Tecnologia (PTDC/MEC-URG/29561/2017, SFRH/BD/128579/2017)

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: The Challenges of Developing Biosensors for Clinical Assessment: A Review. https://app.cochat.ai/papers/10.3390/chemosensors9110299
The paper
Prabowo, B. A., Cabral, P. D., Freitas, P., & Fernandes, E. (2021). The Challenges of Developing Biosensors for Clinical Assessment: A Review. Chemosensors. https://doi.org/10.3390/chemosensors9110299

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.