The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
The Challenges of Developing Biosensors for Clinical Assessment: A Review
Published version of a preprint
Abstract
Emerging research in biosensors has attracted much attention worldwide, particularly in response to the recent pandemic outbreak of coronavirus disease 2019 (COVID-19). Nevertheless, initiating research in biosensing applied to the diagnosis of diseases is still challenging for researchers, be it in the preferences of biosensor platforms, selection of biomarkers, detection strategies, or other aspects (e.g., cutoff values) to fulfill the clinical purpose. There are two sides to the development of a diagnostic tool: the biosensor development side and the clinical side. From the development side, the research engineers seek the typical characteristics of a biosensor: sensitivity, selectivity, linearity, stability, and reproducibility. On the other side are the physicians that expect a diagnostic tool that provides fast acquisition of patient information to obtain an early diagnosis or an efficient patient stratification, which consequently allows for making assertive and efficient clinical decisions. The development of diagnostic devices always involves assay developer researchers working as pivots to bridge both sides whose role is to find detection strategies suitable to the clinical needs by understanding (1) the intended use of the technology and its basic principle and (2) the preferable type of test: qualitative or quantitative, sample matrix challenges, biomarker(s) threshold (cutoff value), and if the system requires a mono- or multiplex assay format. This review highlights the challenges for the development of biosensors for clinical assessment and its broad application in multidisciplinary fields. This review paper highlights the following biosensor technologies: magnetoresistive (MR)-based, transistor-based, quartz crystal microbalance (QCM), and optical-based biosensors. Its working mechanisms are discussed with their pros and cons. The article also gives an overview of the most critical parameters that are optimized by developing a diagnostic tool.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Strimbu, K., & Tavel, J. A. (2010) · Current Opinion in HIV and AIDS · doi:10.1097/coh.0b013e32833ed177 · Cited by 2,062
Protein biomarker discovery and validation: the long and uncertain path to clinical utility
Rifai, N., Gillette, M. A., & Carr, S. A. (2006) · Nature Biotechnology · doi:10.1038/nbt1235 · Cited by 1,867
Subthreshold Regime has the Optimal Sensitivity for Nanowire FET Biosensors
Gao, X. P. A., Zheng, G., & Lieber, C. M. (2010) · Nano Letters · doi:10.1021/nl9034219 · Cited by 571
Single-Molecule Plasmon Sensing: Current Status and Future Prospects
Taylor, A. B., & Zijlstra, P. (2017) · ACS Sensors · doi:10.1021/acssensors.7b00382 · Cited by 366
Wearable multiplexed biosensor system toward continuous monitoring of metabolites
Yokus, M. A., Songkakul, T., Pozdin, V. A., Bozkurt, A., & Daniele, M. A. (2020) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2020.112038 · Cited by 153
Research works printed but not linked: 176
- Ward, 2020, Novel coronavirus 2019, an emerging public health emergency, Transbound. Emerg. Dis., 67, 469, 10.1111/tbed.13509 · doi:10.1111/tbed.13509
- Udugama, 2020, Diagnosing COVID-19: The Disease and Tools for Detection, ACS Nano, 14, 3822, 10.1021/acsnano.0c02624 · DOI · Paper page
- Nagel, 2009, Glossary for chemists of terms used in biotechnology (IUPAC Recommendations 1992), Pure Appl. Chem., 64, 143, 10.1351/pac199264010143 · DOI
- Puiu, 2020, Microfluidics-integrated biosensing platforms as emergency tools for on-site field detection of foodborne pathogens, TrAC Trends Anal. Chem., 125, 115831, 10.1016/j.trac.2020.115831 · doi:10.1016/j.trac.2020.115831
- Selleck, 2017, Making Meaningful Clinical Use of Biomarkers, Biomark. Insights, 12, 1177271917715236, 10.1177/1177271917715236 · DOI · Paper page
- Fullerton, 2016, Spintronics, Magnetoresistive Heads, and the Emergence of the Digital World, Proc. IEEE, 104, 1787, 10.1109/JPROC.2016.2567778 · DOI
- Wang, 2015, Giant magnetoresistive-based biosensing probe station system for multiplex protein assays, Biosens. Bioelectron., 70, 61, 10.1016/j.bios.2015.03.011 · DOI
- Marquina, 2012, GMR sensors and magnetic nanoparticles for immuno-chromatographic assays, J. Magn. Magn. Mater., 324, 3495, 10.1016/j.jmmm.2012.02.074 · DOI
- Wu, 2019, Magnetic nanoparticles in nanomedicine: A review of recent advances, Nanotechnology, 30, 502003, 10.1088/1361-6528/ab4241 · DOI · Paper page
- Mu, 2019, A new rapid detection method for ricin based on tunneling magnetoresistance biosensor, Sens. Actuators B Chem., 284, 638, 10.1016/j.snb.2018.12.127 · DOI
- Kim, 2018, Magnetoresistive biosensors with on-chip pulsed excitation and magnetic correlated double sampling, Sci. Rep., 8, 16493, 10.1038/s41598-018-34720-0 · doi:10.1038/s41598-018-34720-0
- Hall, 2010, GMR biosensor arrays: Correction techniques for reproducibility and enhanced sensitivity, Biosens. Bioelectron., 25, 2177, 10.1016/j.bios.2010.01.039 · doi:10.1016/j.bios.2010.01.039
- Purwidyantri, A., Tian, Y., Muhammad, G., Saputra, A., and Prabowo, B.A. (2021). Gold Nanoframe Array Electrode for Straightforward Detection of Hydrogen Peroxide. Chemosensors, 9. · DOI
- Bhattacharyya, 2019, Specific and label-free immunosensing of protein-protein interactions with silicon-based immunoFETs, Biosens. Bioelectron., 132, 143, 10.1016/j.bios.2019.03.003 · DOI
- Danielson, 2020, Graphene based field-effect transistor biosensors functionalized using gas-phase synthesized gold nanoparticles, Sens. Actuators B Chem., 320, 128432, 10.1016/j.snb.2020.128432 · DOI
- Kuznetsov, 2019, Integration of a field effect transistor-based aptasensor under a hydrophobic membrane for bioelectronic nose applications, Biosens. Bioelectron., 129, 29, 10.1016/j.bios.2019.01.013 · doi:10.1016/j.bios.2019.01.013
- Park, 2020, Interfacial charge regulation of protein blocking layers in transistor biosensor for direct measurement in serum, Biosens. Bioelectron., 147, 111737, 10.1016/j.bios.2019.111737 · doi:10.1016/j.bios.2019.111737
- Pletinck, A., Van Biesen, W., Dequidt, C., and Eloot, S. (2018). Transport of neutral IgG2 versus anionic IgG4 in PD: Implications on the electrokinetic model. BMC Nephrol., 19. · doi:10.1186/s12882-018-1104-1
- Pillarisetty, 2011, Academic and industry research progress in germanium nanodevices, Nature, 479, 324, 10.1038/nature10678 · doi:10.1038/nature10678
- Jing, 2020, Engineering Field Effect Transistors with 2D Semiconducting Channels: Status and Prospects, Adv. Funct. Mater., 30, 1
- Jang, 2013, Sensitivity enhancement of amorphous InGaZnO thin film transistor based extended gate field-effect transistors with dual-gate operation, Sens. Actuators B Chem., 181, 880, 10.1016/j.snb.2013.02.056 · DOI · Paper page
- Guan, 2014, Highly specific and sensitive non-enzymatic determination of uric acid in serum and urine by extended gate field effect transistor sensors, Biosens. Bioelectron., 51, 225, 10.1016/j.bios.2013.07.061 · DOI
- Purwidyantri, 2018, A Colloidal Nanopatterning and Downscaling of a Highly Periodic Au Nanoporous EGFET Biosensor, J. Electrochem. Soc., 165, H3170, 10.1149/2.0241804jes · DOI
- 2012, The cell adhesion and cytotoxicity effects of the derivate of vitamin e compared for two cell lines using a piezoelectric biosensor, Sens. Actuators B Chem., 174, 153, 10.1016/j.snb.2012.08.047 · doi:10.1016/j.snb.2012.08.047
- Bianco, 2018, Quartz Crystal Microbalance as Cell-Based Biosensor to Detect and Study Cytoskeletal Alterations and Dynamics, Biotechnol. J., 13, 1700699, 10.1002/biot.201700699 · DOI
- Xu, 2016, A target-responsive and size-dependent hydrogel aptasensor embedded with QD fluorescent reporters for rapid detection of avian influenza virus H5N1, Sens. Actuators B Chem., 234, 98, 10.1016/j.snb.2016.04.156 · DOI
- Jean, 2020, Quartz crystal microbalance-based biosensors as rapid diagnostic devices for infectious diseases, Biosens. Bioelectron., 168, 112513, 10.1016/j.bios.2020.112513 · DOI · Paper page
- Fu, 2017, Advances in piezoelectric thin films for acoustic biosensors, acoustofluidics and lab-on-chip applications, Prog. Mater. Sci., 89, 31, 10.1016/j.pmatsci.2017.04.006 · DOI · Paper page
- Prabowo, B.A., Purwidyantri, A., and Liu, K.-C.C. (2018). Surface Plasmon Resonance Optical Sensor: A Review on Light Source Technology. Biosensors, 8. · DOI
- Long, Y.-T., and Jing, C. (2014). Localized Surface Plasmon Resonance based Nanobiosensors., Springer. · doi:10.1007/978-3-642-54795-9
- Szunerits, 2014, Surface plasmon resonance: Signal amplification using colloidal gold nanoparticles for enhanced sensitivity, Rev. Anal. Chem., 33, 153, 10.1515/revac-2014-0011 · DOI
- Lin, H.T.-H., Yang, C.-K., Lin, C.-C., Wu, A.M.-H., Wang, L.A., and Huang, N.-T. (2017). A Large-Area Nanoplasmonic Sensor Fabricated by Rapid Thermal Annealing Treatment for Label-Free and Multi-Point Immunoglobulin Sensing. Nanomaterials, 7. · doi:10.3390/nano7050100
- Adegoke, 2017, Localized surface plasmon resonance-mediated fluorescence signals in plasmonic nanoparticle-quantum dot hybrids for ultrasensitive Zika virus RNA detection via hairpin hybridization assays, Biosens. Bioelectron., 94, 513, 10.1016/j.bios.2017.03.046 · doi:10.1016/j.bios.2017.03.046
- Gupta, 2020, ZnO-Nanorod processed PC-SET as the light-harvesting model for plasmontronic fluorescence Sensor, Sens. Actuators B Chem., 307, 127597, 10.1016/j.snb.2019.127597 · doi:10.1016/j.snb.2019.127597
- Su, 2019, Two-dimensional nanomaterials for biosensing applications, TrAC Trends Anal. Chem., 119, 115610, 10.1016/j.trac.2019.07.021 · DOI · Paper page
- Wang, 2010, Nanomaterial-assisted aptamers for optical sensing, Biosens. Bioelectron., 25, 1859, 10.1016/j.bios.2009.11.012 · doi:10.1016/j.bios.2009.11.012
- Prabowo, 2021, Gold nanoparticle-assisted plasmonic enhancement for DNA detection on a graphene-based portable surface plasmon resonance sensor, Nanotechnology, 32, 095503, 10.1088/1361-6528/abcd62 · doi:10.1088/1361-6528/abcd62
- Rossi, 2014, Biosensor analysis of anti-citrullinated protein/peptide antibody affinity, Anal. Biochem., 465C, 96, 10.1016/j.ab.2014.07.030 · doi:10.1016/j.ab.2014.07.030
- Gopinath, 2010, Biosensing applications of surface plasmon resonance-based Biacore technology, Sens. Actuators B, 150, 722, 10.1016/j.snb.2010.08.014 · DOI
- Guner, 2017, A smartphone based surface plasmon resonance imaging (SPRi) platform for on-site biodetection, Sens. Actuators B Chem., 239, 571, 10.1016/j.snb.2016.08.061 · DOI · Paper page
- Wuytens, 2017, On-chip surface-enhanced Raman spectroscopy using nanosphere-lithography patterned antennas on silicon nitride waveguides, Opt. Express, 25, 12926, 10.1364/OE.25.012926 · DOI
- Anker, 2008, Biosensing with plasmonic nanosensors, Nat. Mater., 7, 442, 10.1038/nmat2162 · DOI · Paper page
- Zheng, 2017, Semiconductor SERS enhancement enabled by oxygen incorporation, Nat. Commun., 8, 1993, 10.1038/s41467-017-02166-z · DOI · Paper page
- Purwidyantri, 2019, Plasmonic nanomaterial structuring for SERS enhancement, RSC Adv., 9, 4982, 10.1039/C8RA10656H · DOI
- Tang, 2018, Cellular imaging by targeted assembly of hot-spot SERS and photoacoustic nanoprobes using split-fluorescent protein scaffolds, Nat. Commun., 9, 607, 10.1038/s41467-018-03046-w · DOI
- Gong, 2015, Highly sensitive SERS detection and quantification of sialic acid on single cell using photonic-crystal fiber with gold nanoparticles, Biosens. Bioelectron., 64, 227, 10.1016/j.bios.2014.08.077 · DOI
- Kang, 2015, Repeated Solid-state Dewetting of Thin Gold Films for Nanogap-rich Plasmonic Nanoislands, Sci. Rep., 5, 14790, 10.1038/srep14790 · DOI
- Kim, 2018, Low-cost, high-performance plasmonic nanocomposites for hazardous chemical detection using surface enhanced Raman scattering, Sens. Actuators B Chem., 274, 30, 10.1016/j.snb.2018.07.107 · DOI
- Yang, 2015, Ultrasensitive surface-enhanced Raman scattering detection in common fluids, Proc. Natl. Acad. Sci. USA, 113, 268, 10.1073/pnas.1518980113 · DOI · Paper page
- Zhang, 2017, A metallic molybdenum dioxide with high stability for surface enhanced Raman spectroscopy, Nat. Commun., 8, 14903, 10.1038/ncomms14903 · DOI · Paper page
- Liu, 2019, Low fouling strategies for electrochemical biosensors targeting disease biomarkers, Anal. Methods, 11, 702, 10.1039/C8AY02674B · DOI
- Liu, 2016, Design and mechanisms of antifouling materials for surface plasmon resonance sensors, Acta Biomater., 40, 100, 10.1016/j.actbio.2016.02.035 · DOI
- Qian, 2019, Fiber optic surface plasmon resonance biosensor for detection of PDGF-BB in serum based on self-assembled aptamer and antifouling peptide monolayer, Biosens. Bioelectron., 140, 111350, 10.1016/j.bios.2019.111350 · doi:10.1016/j.bios.2019.111350
- Zhang, 2014, Amplified amperometric aptasensor for selective detection of protein using catalase-functional DNA-PtNPs dendrimer as a synergetic signal amplification label, Biosens. Bioelectron., 60, 224, 10.1016/j.bios.2014.04.024 · doi:10.1016/j.bios.2014.04.024
- Park, 2014, An ultra-sensitive detection of a whole virus using dual aptamers developed by immobilization-free screening, Biosens. Bioelectron., 51, 324, 10.1016/j.bios.2013.07.052 · doi:10.1016/j.bios.2013.07.052
- Chang, 2013, Using a fiber optic particle plasmon resonance biosensor to determine kinetic constants of antigen-antibody binding reaction, Anal. Chem., 85, 245, 10.1021/ac302590n · DOI
- Ali, 2012, Cell-surface sensors: Lighting the cellular environment, Wiley Interdiscip. Rev. Nanomed. Nanobiotechnol., 4, 547, 10.1002/wnan.1179 · DOI
- Chen, 2017, Field-effect transistor biosensors with two-dimensional black phosphorus nanosheets, Biosens. Bioelectron., 89, 505, 10.1016/j.bios.2016.03.059 · doi:10.1016/j.bios.2016.03.059
- Naylor, 2016, Scalable Production of Molybdenum Disul fi de Based Biosensors, ACS Nano, 10, 6173, 10.1021/acsnano.6b02137 · DOI
- Mao, 2017, Two-dimensional nanomaterial-based field-effect transistors for chemical and biological sensing, Chem. Soc. Rev., 46, 6872, 10.1039/C6CS00827E · DOI · Paper page
- Comini, 2009, Quasi-one dimensional metal oxide semiconductors: Preparation, characterization and application as chemical sensors, Prog. Mater. Sci., 54, 1, 10.1016/j.pmatsci.2008.06.003 · DOI · Paper page
- Ramnani, 2016, Carbon nanomaterial-based electrochemical biosensors for label-free sensing of environmental pollutants, Chemosphere, 143, 85, 10.1016/j.chemosphere.2015.04.063 · DOI · Paper page
- Afsahi, 2018, Novel graphene-based biosensor for early detection of Zika virus infection, Biosens. Bioelectron., 100, 85, 10.1016/j.bios.2017.08.051 · doi:10.1016/j.bios.2017.08.051
- Xu, 2014, Electrophoretic and field-effect graphene for all-electrical DNA array technology, Nat. Commun., 5, 4866, 10.1038/ncomms5866 · DOI
- Mao, 2010, Specific protein detection using thermally reduced graphene oxide sheet decorated with gold nanoparticle-antibody conjugates, Adv. Mater., 22, 3521, 10.1002/adma.201000520 · DOI · Paper page
- Purwidyantri, A., Domingues, T., Guerreiro, J.R., Ipatov, A., Abreu, C.M., Martins, M., Alpuim, P., and Prado, M. (2021). Influence of the Electrolyte Salt Concentration on DNA Detection with Graphene Transistors. Biosensors, 11. · DOI
- Sarkar, 2014, MoS2 field-effect transistor for next-generation label-free biosensors, ACS Nano, 8, 3992, 10.1021/nn5009148 · DOI · Paper page
- Lee, 2015, Field-effect transistor with a chemically synthesized MoS2 sensing channel for label-free and highly sensitive electrical detection of DNA hybridization, Nano Res., 8, 2340, 10.1007/s12274-015-0744-8 · DOI
- Wang, 2020, Competitive electrochemical aptasensor based on a cDNA-ferrocene/MXene probe for detection of breast cancer marker Mucin1, Anal. Chim. Acta, 1094, 18, 10.1016/j.aca.2019.10.003 · DOI · Paper page
- Lim, 2013, A peptide receptor-based bioelectronic nose for the real-time determination of seafood quality, Biosens. Bioelectron., 39, 244, 10.1016/j.bios.2012.07.054 · DOI
- Lee, 2010, Low-cost, transparent, and flexible single-walled carbon nanotube nanocomposite based ion-sensitive field-effect transistors for pH/glucose sensing, Biosens. Bioelectron., 25, 2259, 10.1016/j.bios.2010.03.003 · DOI
- Park, 2014, Human dopamine receptor nanovesicles for gate-potential modulators in high-performance field-effect transistor biosensors, Sci. Rep., 4, 4342, 10.1038/srep04342 · DOI
- Jun, 2014, Aptamer-Functionalized Hybrid Carbon Nano fi ber FET-Type Electrode for a Highly Sensitive and Selective Platelet-Derived Growth Factor Biosensor, Appl. Mater. Interface, 6, 13859, 10.1021/am5032693 · DOI
- Chen, 2017, High-sensitivity and large-dynamic-range refractive index sensors employing weak composite Fabry-Perot cavities, Opt. Lett., 42, 3145, 10.1364/OL.42.003145 · doi:10.1364/ol.42.003145
- Prabowo, 2019, Nano-film aluminum-gold for ultra-high dynamic-range surface plasmon resonance chemical sensor, Front. Optoelectron., 12, 286, 10.1007/s12200-019-0864-y · doi:10.1007/s12200-019-0864-y
- Chou, 2016, Ultra-low fouling and high antibody loading zwitterionic hydrogel coatings for sensing and detection in complex media, Acta Biomater., 40, 31, 10.1016/j.actbio.2016.04.023 · DOI
- Singha, 2018, Au nanoparticles functionalized 3D-MoS2 nanoflower: An efficient SERS matrix for biomolecule sensing, Biosens. Bioelectron., 119, 10, 10.1016/j.bios.2018.07.061 · DOI
- Purwidyantri, 2017, Speckled ZnO Nanograss Electrochemical Sensor for Staphylococcus epidermidis Detection, J. Electrochem. Soc., 164, B205, 10.1149/2.0811706jes · doi:10.1149/2.0811706jes
- Prabowo, B.A. (2019, January 23–24). The Trade-Off Performance of Surface Plasmon Resonance Sensing Utilizing Thin Layer Oxide under the Metal Layer. Proceedings of the 2019 International Conference on Radar, Antenna, Microwave, Electronics, and Telecommunications (ICRAMET), Serpong, Indonesia. · doi:10.1109/icramet47453.2019.8980455
- Fernandes, 2020, Point-of-care quantification of serum cellular fibronectin levels for stratification of ischemic stroke patients, Nanomed. Nanotechnol. Biol. Med., 30, 102287, 10.1016/j.nano.2020.102287 · doi:10.1016/j.nano.2020.102287
- Kamat, 2017, Designing binding kinetic assay on the bio-layer interferometry (BLI) biosensor to characterize antibody-antigen interactions, Anal. Biochem., 536, 16, 10.1016/j.ab.2017.08.002 · DOI
- Sharma, 2016, Antibodies and antibody-derived analytical biosensors, Essays Biochem., 60, 9, 10.1042/EBC20150002 · DOI · Paper page
- Long, 1983, Limit of Detection a Closer Look at the IUPAC Definition, Anal. Chem., 55, 712A
- Currie, 1999, Nomenclature in evaluation of analytical methods including detection and quantification capabilities. Adapted from the International Union of Pure and Applied Chemistry (IUPAC) document “Nomenclature in Evaluation of Analytical Methods including Detection, Anal. Chim. Acta, 391, 105, 10.1016/S0003-2670(99)00104-X · DOI
- Stroot, 2012, Capture antibody targeted fluorescence in situ hybridization (CAT-FISH): Dual labeling allows for increased specificity in complex samples, J. Microbiol. Methods, 88, 275, 10.1016/j.mimet.2011.12.009 · doi:10.1016/j.mimet.2011.12.009
- Duman, 2010, Detection of Mycobacterium tuberculosis complex and Mycobacterium gordonae on the same portable surface plasmon resonance sensor, Biosens. Bioelectron., 26, 908, 10.1016/j.bios.2010.06.071 · doi:10.1016/j.bios.2010.06.071
- Chauhan, 2020, Nanostructured transition metal chalcogenide embedded on reduced graphene oxide based highly efficient biosensor for cardiovascular disease detection, Microchem. J., 155, 104697, 10.1016/j.microc.2020.104697 · doi:10.1016/j.microc.2020.104697
- Deng, 2013, An aptamer-based biosensing platform for highly sensitive detection of platelet-derived growth factor via enzyme-mediated direct electrochemistry, Anal. Chim. Acta, 759, 61, 10.1016/j.aca.2012.11.018 · doi:10.1016/j.aca.2012.11.018
- Xie, 2018, Simultaneous detection of Dengue and Zika virus RNA sequences with a three-dimensional Cu-based zwitterionic metal–organic framework, comparison of single and synchronous fluorescence analysis, Sens. Actuators B Chem., 254, 1133, 10.1016/j.snb.2017.06.085 · doi:10.1016/j.snb.2017.06.085
- Sin, 2014, Hemocompatibility of zwitterionic interfaces and membranes, Polym. J., 46, 436, 10.1038/pj.2014.46 · DOI · Paper page
- Chen, 2014, Synthesis and characterization of antifouling poly(N-acryloylaminoethoxyethanol) with ultralow protein adsorption and cell attachment, Langmuir, 30, 10398, 10.1021/la502136q · DOI
- Riedel, 2014, Diagnosis of Epstein-Barr virus infection in clinical serum samples by an SPR biosensor assay, Biosens. Bioelectron., 55, 278, 10.1016/j.bios.2013.12.011 · doi:10.1016/j.bios.2013.12.011
- Homola, 2012, Biofunctionalized gold nanoparticles for SPR-biosensor-based detection of CEA in blood plasma, Anal. Bioanal. Chem., 404, 2869, 10.1007/s00216-012-6308-9 · doi:10.1007/s00216-012-6308-9
- Liu, G., Gurung, A.S., and Qiu, W. (2019). Lateral flow aptasensor for simultaneous detection of platelet-derived growth factor-BB (PDGF-BB) and thrombin. Molecules, 24. · doi:10.3390/molecules24040756
- Chen, 2018, Ultrasensitive photoelectrochemical immunosensor of cardiac troponin I detection based on dual inhibition effect of Ag@Cu2O core-shell submicron-particles on CdS QDs sensitized TiO2 nanosheets, Biosens. Bioelectron., 117, 340, 10.1016/j.bios.2018.05.037 · doi:10.1016/j.bios.2018.05.037
- Averseng, 2010, Surface plasmon resonance for rapid screening of uranyl affine proteins, Anal. Chem., 82, 9797, 10.1021/ac102578y · doi:10.1021/ac102578y
- Bartlett, 2008, Reliability, repeatability and reproducibility: Analysis of measurement errors in continuous variables, Ultrasound Obstet. Gynecol., 31, 466, 10.1002/uog.5256 · DOI · Paper page
- Cipriani, 2020, Increased circulating levels of Factor H-Related Protein 4 are strongly associated with age-related macular degeneration, Nat. Commun., 11, 778, 10.1038/s41467-020-14499-3 · DOI
- Gu, 2018, SERS Sensors: Recent Developments and a Generalized Classification Scheme Based on the Signal Origin, Annu. Rev. Anal. Chem., 11, 147, 10.1146/annurev-anchem-061417-125724 · DOI
- Prabowo, 2018, Rapid screening of Mycobacterium tuberculosis complex (MTBC) in clinical samples by a modular portable biosensor, Sens. Actuators B Chem., 254, 742, 10.1016/j.snb.2017.07.102 · doi:10.1016/j.snb.2017.07.102
- Prabowo, 2017, Rapid detection and quantification of Enterovirus 71 by a portable surface plasmon resonance biosensor, Biosens. Bioelectron., 92, 186, 10.1016/j.bios.2017.01.043 · doi:10.1016/j.bios.2017.01.043
- Chen, 2012, Study on the performance promotion of the surface plasmon resonance analytical system, Instrum. Sci. Technol., 40, 226, 10.1080/10739149.2011.651672 · doi:10.1080/10739149.2011.651672
- Wang, 2012, Without-baseline centroid algorithm for surface plasmon resonance spectra, Chin. J. Sens. Actuators, 25, 365
- Dong, 2007, High-sensitivity, large dynamic range, auto-calibration methane optical sensor using a short confocal Fabry-Perot cavity, Sens. Actuators B Chem., 127, 350, 10.1016/j.snb.2007.04.030 · doi:10.1016/j.snb.2007.04.030
- Atkinson, 2001, Biomarkers and surrogate endpoints: Preferred definitions and conceptual framework, Clin. Pharmacol. Ther., 69, 89, 10.1067/mcp.2001.113989 · DOI · Paper page
- Moroncini, 2017, Characterization of binding and quantification of human autoantibodies to PDGFRα using a biosensor-based approach, Anal. Biochem., 528, 26, 10.1016/j.ab.2017.04.011 · DOI
- Yakhno, 2007, Uncoated quartz resonator as a universal biosensor, Biosens. Bioelectron., 22, 2127, 10.1016/j.bios.2006.09.029 · DOI
- Babaki, 2017, Antigen 85 complex as a powerful Mycobacterium tuberculosis immunogene: Biology, immune-pathogenicity, applications in diagnosis, and vaccine design, Microb. Pathog., 112, 20, 10.1016/j.micpath.2017.08.040 · DOI
- Sobrino, 2013, Prometalloproteinase-10 is associated with brain damage and clinical outcome in acute ischemic stroke, J. Thromb. Haemost., 11, 1464, 10.1111/jth.12312 · DOI
- Hamzeiy, 2014, Nanoscaled aptasensors for multi-analyte sensing, BioImpacts, 4, 205
- Sefah, 2009, Nucleic acid aptamers for biosensors and bio-analytical applications, Analyst, 134, 1765, 10.1039/b905609m · DOI · Paper page
- Oyejide, L., Mendes, O.R., and Mikaelian, I. (2017). Molecular Pathology: Applications in Nonclinical Drug Development. A Comprehensive Guide to Toxicology in Nonclinical Drug Development, Elsevier Inc. · DOI
- Lee, 2019, Circulating biomarkers predictive of tumor response to cancer immunotherapy, Expert Rev. Mol. Diagn., 19, 895, 10.1080/14737159.2019.1659728 · DOI
- Sobrino, 2011, Early biomarkers of clinical-diffusion mismatch in acute ischemic stroke, Stroke, 42, 2813, 10.1161/STROKEAHA.111.614503 · doi:10.1161/strokeaha.111.614503
- Shaqdan, 2014, Incidence of contrast medium extravasation for CT and MRI in a large academic medical centre: A report on 502,391 injections, Clin. Radiol., 69, 1264, 10.1016/j.crad.2014.08.004 · doi:10.1016/j.crad.2014.08.004
- Seher, 2011, Gene expression profiling of connective tissue growth factor (CTGF) stimulated primary human tenon fibroblasts reveals an inflammatory and wound healing response in vitro, Mol. Vis., 17, 53
- Green, 2015, Interactions of DNA with graphene and sensing applications of graphene field-effect transistor devices: A review, Anal. Chim. Acta, 853, 127, 10.1016/j.aca.2014.10.023 · DOI
- Yu, 2017, Proximity hybridization-mediated isothermal exponential amplification for ultrasensitive electrochemical protein detection, Int. J. Nanomed., 12, 5903, 10.2147/IJN.S142015 · DOI
- Razmi, 2018, Recent advances on aptamer-based biosensors to detection of platelet-derived growth factor, Biosens. Bioelectron., 113, 58, 10.1016/j.bios.2018.04.048 · doi:10.1016/j.bios.2018.04.048
- Hong, 2017, Portable aptamer biosensor of platelet-derived growth factor-BB using a personal glucose meter with triply amplified, Biosens. Bioelectron., 95, 152, 10.1016/j.bios.2017.04.023 · DOI
- Sameiyan, 2019, DNA origami-based aptasensors, Biosens. Bioelectron., 143, 111662, 10.1016/j.bios.2019.111662 · DOI
- Bagheri, 2018, Triple-helix molecular switch-based aptasensors and DNA sensors, Biosens. Bioelectron., 111, 1, 10.1016/j.bios.2018.03.070 · DOI
- Gilgunn, 2013, Aberrant PSA glycosylation—A sweet predictor of prostate cancer, Nat. Rev. Urol., 10, 99, 10.1038/nrurol.2012.258 · DOI · Paper page
- Tzouvadaki, 2016, Label-free ultrasensitive memristive aptasensor, Nano Lett., 16, 4472, 10.1021/acs.nanolett.6b01648 · DOI
- Yang, 2017, A novel SERS-based magnetic aptasensor for prostate specific antigen assay with high sensitivity, Biosens. Bioelectron., 94, 286, 10.1016/j.bios.2017.02.048 · DOI
- Su, 2013, Detection of cancer biomarkers by piezoelectric biosensor using PZT ceramic resonator as the transducer, Biosens. Bioelectron., 46, 155, 10.1016/j.bios.2013.01.074 · doi:10.1016/j.bios.2013.01.074
- Su, 2010, Detection of prostate-specific antigen with a paired surface plasma wave biosensor, Anal. Chem., 82, 3714, 10.1021/ac100071h · doi:10.1021/ac100071h
- Cao, 2006, A strategy for sensitivity and specificity enhancements in prostate specific antigen-alpha(1)-antichymotrypsin detection based on surface plasmon resonance, Biosens. Bioelectron., 21, 2106, 10.1016/j.bios.2005.10.014 · doi:10.1016/j.bios.2005.10.014
- Sisinni, 2015, The Role of Human Chorionic Gonadotropin as Tumor Marker: Biochemical and Clinical Aspects, Adv. Exp. Med. Biol., 867, 229, 10.1007/978-94-017-7215-0_14 · doi:10.1007/978-94-017-7215-0_14
- Liu, 2013, Multiplexed immunoassay biosensor for the detection of serum biomarkers - β-HCG and AFP of Down Syndrome based on photoluminescent water-soluble CdSe/ZnS quantum dots, Sens. Actuators B Chem., 186, 235, 10.1016/j.snb.2013.05.094 · doi:10.1016/j.snb.2013.05.094
- Matsui, 2003, Criteria for Initiating Chemotherapy in Patients after Evacuation of Hydatidiform Mole, Tumor Biol., 24, 140, 10.1159/000073843 · doi:10.1159/000073843
- Lei, H., Wang, K., Ji, X., and Cui, D. (2016). Contactless measurement of magnetic nanoparticles on lateral flow strips using tunneling magnetoresistance (TMR) sensors in differential configuration. Sensors (Switzerland), 16. · DOI
- Khodadadi, M., Chang, L., Trabuco, J.R.C., Vu, B.V., Kourentzi, K., Willson, R.C., and Litvinov, D. (2019). PCB-based magnetometer as a platform for quantification of lateral-flow assays. Sensors (Switzerland), 19. · doi:10.3390/s19245433
- Yan, 2019, Machine Learning Approach to Enhance the Performance of MNP-Labeled Lateral Flow Immunoassay, Nano-Micro Lett., 11, 7, 10.1007/s40820-019-0239-3 · DOI
- Piliarik, 2010, Real-time monitoring of biomolecular interactions in blood plasma using a surface plasmon resonance biosensor, Anal. Bioanal. Chem., 398, 1955, 10.1007/s00216-010-4159-9 · doi:10.1007/s00216-010-4159-9
- Chang, 2014, Colorimetric detection of human chorionic gonadotropin using catalytic gold nanoparticles and a peptide aptamer, Chem. Commun., 50, 14443, 10.1039/C4CC06366J · DOI
- Chung, 2012, Human chorionic gonadotropin interactions with immobilized anti-hCG studied by quartz-crystal microbalance with dissipation monitoring, J. Biomed. Mater. Res. -Part A, 100A, 1600, 10.1002/jbm.a.34100 · doi:10.1002/jbm.a.34100
- Liao, 2019, Electrical Double Layer Gated Field Effect Transistor Biosensors for the Quantitative Detection of Beta-Human Chorionic Gonadotropin, ECS Trans., 92, 57, 10.1149/09206.0057ecst · doi:10.1149/09206.0057ecst
- Wu, 2009, Specificity of a High-Sensitivity Cardiac Troponin I Assay Using Single-Molecule–Counting Technology, Clin. Chem., 55, 196, 10.1373/clinchem.2008.108837 · doi:10.1373/clinchem.2008.108837
- Kavsak, 2009, Short- and long-term risk stratification using a next-generation, high-sensitivity research cardiac troponin I (hs-cTnI) assay in an Emergency Department Chest Pain Population, Clin. Chem., 55, 1809, 10.1373/clinchem.2009.127241 · doi:10.1373/clinchem.2009.127241
- Liu, 2020, A microfabricated thickness shear mode electroacoustic resonator for the label-free detection of cardiac troponin in serum, Talanta, 215, 120890, 10.1016/j.talanta.2020.120890 · DOI
- Patra, 2017, Using extraordinary optical transmission to quantify cardiac biomarkers in human serum, J. Vis. Exp., 2017, 55597
- Krupin, O., and Berini, P. (2019). Long-range surface plasmon-polariton waveguide biosensors for human cardiac troponin I detection. Sensors (Switzerland), 19. · DOI
- Han, 2018, Ultrasensitive Plasmonic Biosensors for Real-Time Parallel Detection of Alpha-L-Fucosidase and Cardiac-Troponin-I in Whole Human Blood, Anal. Chem., 90, 7795, 10.1021/acs.analchem.8b01816 · DOI
- Wu, 2017, Ultrasensitive magnetic field-assisted surface plasmon resonance immunoassay for human cardiac troponin I, Biosens. Bioelectron., 96, 288, 10.1016/j.bios.2017.05.023 · DOI
- Liyanage, 2017, Achieving biosensing at attomolar concentrations of cardiac troponin T in human biofluids by developing a label-free nanoplasmonic analytical assay, Analyst, 142, 2442, 10.1039/C7AN00430C · doi:10.1039/c7an00430c
- Wu, 2017, Hollow gold nanoparticle-enhanced SPR based sandwich immunoassay for human cardiac troponin I, Microchim. Acta, 184, 2395, 10.1007/s00604-017-2245-9 · DOI
- Sarangadharan, 2018, Single Drop Whole Blood Diagnostics: Portable Biomedical Sensor for Cardiac Troponin i Detection, Anal. Chem., 90, 2867, 10.1021/acs.analchem.7b05018 · DOI
- Sarangadharan, 2018, High sensitivity cardiac troponin I detection in physiological environment using AlGaN/GaN High Electron Mobility Transistor (HEMT) Biosensors, Biosens. Bioelectron., 100, 282, 10.1016/j.bios.2017.09.018 · DOI · Paper page
- Sarangadharan, 2018, Whole blood cvd diagnostics using portable fet biosensor system, ECS Trans., 85, 25, 10.1149/08509.0025ecst · doi:10.1149/08509.0025ecst
- Huang, 2019, Study of stability and sensitivity of cardiac troponin I based on FET sensor, ECS Trans., 89, 57, 10.1149/08906.0057ecst · doi:10.1149/08906.0057ecst
- Cai, 2015, Gold nanoparticles-decorated graphene field-effect transistor biosensor for femtomolar MicroRNA detection, Biosens. Bioelectron., 74, 329, 10.1016/j.bios.2015.06.068 · DOI · Paper page
- Duffy, 2020, Biomarkers for prostate cancer: Prostate-specific antigen and beyond, Clin. Chem. Lab. Med., 58, 326, 10.1515/cclm-2019-0693 · DOI · Paper page
- Marinca, 2019, KRAS, NRAS, BRAF, HER2 and microsatellite instability in metastatic colorectal cancer-practical implications for the clinician, Radiol. Oncol., 53, 265, 10.2478/raon-2019-0033 · DOI · Paper page
- Muinao, 2019, Multi-biomarker panel signature as the key to diagnosis of ovarian cancer, Heliyon, 5, e02826, 10.1016/j.heliyon.2019.e02826 · DOI
- Katchman, 2016, Application of flat panel OLED display technology for the point-of-care detection of circulating cancer biomarkers, Sci. Rep., 6, 29057, 10.1038/srep29057 · DOI
- Qureshi, 2010, Label-free capacitive biosensor for sensitive detection of multiple biomarkers using gold interdigitated capacitor arrays, Biosens. Bioelectron., 25, 2318, 10.1016/j.bios.2010.03.018 · doi:10.1016/j.bios.2010.03.018
- Muthukumar, 2017, Ultrasensitive nanostructure sensor arrays on flexible substrates for multiplexed and simultaneous electrochemical detection of a panel of cardiac biomarkers, Biosens. Bioelectron., 89, 764, 10.1016/j.bios.2016.10.046 · DOI
- Issadore, 2012, Ultrasensitive clinical enumeration of rare cells ex vivo using a micro-hall detector, Sci. Transl. Med., 4, 141ra92, 10.1126/scitranslmed.3003747 · DOI · Paper page
- Ewald, 2020, A multi-analyte biosensor for the simultaneous label-free detection of pathogens and biomarkers in point-of-need animal testing, Anal. Bioanal. Chem., 407, 4005, 10.1007/s00216-015-8562-0 · doi:10.1007/s00216-015-8562-0
- Fountoglou, 2016, Two-panel molecular testing for genetic predisposition for thrombosis using multi-allele visual biosensors, Anal. Bioanal. Chem., 408, 1943, 10.1007/s00216-016-9310-9 · doi:10.1007/s00216-016-9310-9
- Lee, 2015, A nanoplasmonic biosensor for label-free multiplex detection of cancer biomarkers, Biosens. Bioelectron., 74, 341, 10.1016/j.bios.2015.06.059 · DOI
- Jiang, 2017, Aptamer/AuNP Biosensor for Colorimetric Profiling of Exosomal Proteins, Angew. Chem. -Int. Ed., 56, 11916, 10.1002/anie.201703807 · DOI · Paper page
- Wang, Y.Y., Yuan, W., Zhang, Q., Wang, Y.Y., Kimber, M., Dong, L., and Lu, M. Exosome microarray based on label-free imaging biosensor. Proceedings of the IEEE Sensors.
- Prasad, 2017, Companion and Point-of-Care Sensor System for Rapid Multiplexed Detection of a Panel of Infectious Disease Markers, SLAS Technol. Transl. Life Sci. Innov., 22, 338
- Felder, 2014, MUC16 (CA125): Tumor biomarker to cancer therapy, a work in progress, Mol. Cancer, 13, 129, 10.1186/1476-4598-13-129 · DOI · Paper page
- Skates, 1995, Toward an optimal algorithm for ovarian cancer screening with longitudinal tumor markers, Cancer, 76, 2004, 10.1002/1097-0142(19951115)76:10+<2004::AID-CNCR2820761317>3.0.CO;2-G · doi:10.1002/1097-0142(19951115)76:10+<2004::aid-cncr2820761317>3.0.co;2-g
- Fakanya, 2014, Detection of the inflammation biomarker C-reactive protein in serum samples: Towards an optimal biosensor formula, Biosensors, 4, 340, 10.3390/bios4040340 · DOI
- Ling, 2020, C-reactive protein levels in the early stage of COVID-19, Médecine Mal. Infect., 50, 332, 10.1016/j.medmal.2020.03.007 · DOI · Paper page
- Blanco, 2012, Update on the research of serum biomarkers to assess stroke, Drugs Future, 37, 283, 10.1358/dof.2012.37.4.1769799 · doi:10.1358/dof.2012.37.4.1769799
- Jickling, 2011, Blood Biomarkers of Ischemic Stroke, Neurotherapeutics, 8, 349, 10.1007/s13311-011-0050-4 · DOI · Paper page
- Maestrini, 2016, Blood biomarkers in the early stage of cerebral ischemia, Rev. Neurol. (Paris), 172, 198, 10.1016/j.neurol.2016.02.003 · DOI
- Blanco, 2013, Platelet derived growth factor-CC isoform is associated with hemorrhagic transformation in ischemic stroke patients treated with tissue plasminogen activator, Atherosclerosis, 226, 165, 10.1016/j.atherosclerosis.2012.10.072 · doi:10.1016/j.atherosclerosis.2012.10.072
- Sobrino, 2011, Association between neuroserpin and molecular markers of brain damage in patients with acute ischemic stroke, J. Transl. Med., 9, 58, 10.1186/1479-5876-9-58 · doi:10.1186/1479-5876-9-58
- Foerch, 2007, Elevated serum S100B levels indicate a higher risk of hemorrhagic transformation after thrombolytic therapy in acute stroke, Stroke, 38, 2491, 10.1161/STROKEAHA.106.480111 · DOI
- Wood, 2011, Development and validation of a multiplex microsphere-based assay for detection of domestic cat (Felis catus) cytokines, Clin. Vaccine Immunol., 18, 387, 10.1128/CVI.00289-10 · doi:10.1128/cvi.00289-10
Cited by
AI-Assisted Detection of Biomarkers by Sensors and Biosensors for Early Diagnosis and Monitoring
Wasilewski, T., Kamysz, W., & Gębicki, J. (2024) · Biosensors · doi:10.3390/bios14070356 · Cited by 290
FluorMango, an RNA-based fluorogenic biosensor for the direct and specific detection of fluoride
Husser, C., Vuilleumier, S., & Ryckelynck, M. (2023) · Small · doi:10.1002/smll.202205232 · Cited by 30
Metadata
- Authors
- Prabowo, B. A., Cabral, P. D., Freitas, P., & Fernandes, E.
- Venue
- Chemosensors
- Publisher
- MDPI AG
- Published
- 2021-10-24
- Volume
- 9
- Issue
- 11
- Pages
- 299
- ISSN
- 2227-9040
- Cited by
- 113
- References
- 5
- Language
- en
- Funders
- Fundação para a Ciência e Tecnologia (PTDC/MEC-URG/29561/2017, SFRH/BD/128579/2017)
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: The Challenges of Developing Biosensors for Clinical Assessment: A Review. https://app.cochat.ai/papers/10.3390/chemosensors9110299
- The paper
- Prabowo, B. A., Cabral, P. D., Freitas, P., & Fernandes, E. (2021). The Challenges of Developing Biosensors for Clinical Assessment: A Review. Chemosensors. https://doi.org/10.3390/chemosensors9110299
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.