The Use of the Central Vein Sign in the Diagnosis of Multiple Sclerosis: A Systematic Review and Meta-analysis
Open accessThe DOI matches its Crossref record; 11 of the 11 references it cites were found in a registry or an index.
Abstract
Background: The central vein sign (CVS) is a radiological feature proposed as a multiple sclerosis (MS) imaging biomarker able to accurately differentiate MS from other white matter diseases of the central nervous system. In this work, we evaluated the pooled proportion of the CVS in brain MS lesions and to estimate the diagnostic performance of CVS to perform a diagnosis of MS and propose an optimal cut-off value. Methods: A systematic search was performed on publicly available databases (PUBMED/MEDLINE and Web of Science) up to 24 August 2020. Analysis of the proportion of white matter MS lesions with a central vein was performed using bivariate random-effect models. A meta-regression analysis was performed and the impact of using particular sequences (such as 3D echo-planar imaging) and post-processing techniques (such as FLAIR*) was investigated. Pooled sensibility and specificity were estimated using bivariate models and meta-regression was performed to address heterogeneity. Inclusion and publication bias were assessed using asymmetry tests and a funnel plot. A hierarchical summary receiver operating curve (HSROC) was used to estimate the summary accuracy in diagnostic performance. The Youden index was employed to estimate the optimal cut-off value using individual patient data. Results: The pooled proportion of lesions showing a CVS in the MS population was 73%. The use of the CVS showed a remarkable diagnostic performance in MS cases, providing a pooled specificity of 92% and a sensitivity of 95%. The optimal cut-off value obtained from the individual patient data pooled together was 40% with excellent accuracy calculated by the area under the ROC (0.946). The 3D-EPI sequences showed both a higher pooled proportion compared to other sequences and explained heterogeneity in the meta-regression analysis of diagnostic performances. The 1.5 Tesla (T) scanners showed a lower (58%) proportion of MS lesions with a CVS compared to both 3T (74%) and 7T (82%). Conclusions: The meta-analysis we have performed shows that the use of the CVS in differentiating MS from other mimicking diseases is encouraged; moreover, the use of dedicated sequences such as 3D-EPI and the high MRI field is beneficial.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Diagnosis of multiple sclerosis: 2017 revisions of the McDonald criteria
Thompson, A. J., Banwell, B. L., Barkhof, F., Carroll, W. M., Coetzee, T., Comi, G., Correale, J., Fazekas, F., Filippi, M., Freedman, M. S., et al. (2018) · The Lancet Neurology · doi:10.1016/s1474-4422(17)30470-2 · Cited by 9,476 · cited 1×
“Evaluating the role of more specific magnetic resonance imaging (MRI) features of multiple sclerosis (MS) lesions, such as the central vein sign (CVS), is considered a high-priority area for research according to The International Panel on Diagnosis of MS, which produced the 2017 revised diagnostic criteria [60].”
BackgroundMcInnes, M. D. F., Moher, D., Thombs, B. D., McGrath, T. A., Bossuyt, P. M., and the PRISMA-DTA Group, Clifford, T., Cohen, J. F., Deeks, J. J., Gatsonis, C., et al. (2018) · JAMA · doi:10.1001/jama.2017.19163 · Cited by 3,210
Reich, D. S., Lucchinetti, C. F., & Calabresi, P. A. (2018) · New England Journal of Medicine · doi:10.1056/nejmra1401483 · Cited by 2,491
Bramer, W. M., Rethlefsen, M. L., Kleijnen, J., & Franco, O. H. (2017) · Systematic Reviews · doi:10.1186/s13643-017-0644-y · Cited by 2,114
Distinct lesion morphology at 7-T MRI differentiates neuromyelitis optica from multiple sclerosis
Sinnecker, T., Dörr, J., Pfueller, C. F., Harms, L., Ruprecht, K., Jarius, S., Brück, W., Niendorf, T., Wuerfel, J., & Paul, F. (2012) · Neurology · doi:10.1212/wnl.0b013e3182648bc8 · Cited by 214 · cited 4×
“Of the three studies detecting the CVS i T2*w images [45,50,58], one selected contrast-enhanci g lesions using post-contrast images [45].”
BackgroundInfluentialA Comparison of 3T and 7T in the Detection of Small Parenchymal Veins Within MS Lesions
Tallantyre, E. C., Morgan, P. S., Dixon, J. E., Al-Radaideh, A., Brookes, M. J., Evangelou, N., & Morris, P. G. (2009) · Investigative Radiology · doi:10.1097/rli.0b013e3181b4c144 · Cited by 164 · cited 4×
“5T or 3T but did not provide the proportion of CVS lesions for each scanner and thus was excluded from the sub-group analysis based on the scanner field strength [9]; two studies used both 3T and 7T scanners, however, in our meta-analysis, only the results from the highest field strength were reported as they provided…”
MethodInfluentialThe tension between early diagnosis and misdiagnosis of multiple sclerosis
Solomon, A. J., & Corboy, J. R. (2017) · Nature Reviews Neurology · doi:10.1038/nrneurol.2017.106 · Cited by 89 · cited 1×
“However, their specificity remains limited, especially in the presence of atypical history, and this could result in misdiagnosis and initiation/delay of inappropriate/approved disease-modifying treatment [3].”
BackgroundLiu, S., Kullnat, J., Bourdette, D., Simon, J., Kraemer, D. F., Murchison, C., & Hamilton, B. E. (2013) · Multiple Sclerosis Journal · doi:10.1177/1352458512471874 · Cited by 82
“Better explanations” in multiple sclerosis diagnostic workup: A 3-year longitudinal study
Calabrese, M., Gasperini, C., Tortorella, C., Schiavi, G., Frisullo, G., Ragonese, P., Fantozzi, R., Prosperini, L., Annovazzi, P., Cordioli, C., et al. (2019) · Neurology · doi:10.1212/wnl.0000000000007573 · Cited by 70
Self-citationClarke, M. A., Samaraweera, A. P., Falah, Y., Pitiot, A., Allen, C. M., Dineen, R. A., Tench, C. R., Morgan, P. S., & Evangelou, N. (2020) · Multiple Sclerosis Journal · doi:10.1177/1352458519882282 · Cited by 43
Cited by
Barkhof, F., Reich, D. S., Oh, J., Rocca, M. A., Li, D. K. B., Sati, P., Azevedo, C. J., Bagnato, F., Calabresi, P. A., Ciccarelli, O., et al. (2025) · The Lancet Neurology · doi:10.1016/s1474-4422(25)00304-7 · Cited by 113
Borrelli, S., Martire, M. S., Stölting, A., Vanden Bulcke, C., Pedrini, E., Guisset, F., Bugli, C., Yildiz, H., Pothen, L., Elands, S., et al. (2024) · Neurology Neuroimmunology & Neuroinflammation · doi:10.1212/nxi.0000000000200253 · Cited by 61
La Rosa, F., Wynen, M., Al-Louzi, O., Beck, E. S., Huelnhagen, T., Maggi, P., Thiran, J.-P., Kober, T., Shinohara, R. T., Sati, P., et al. (2022) · NeuroImage: Clinical · doi:10.1016/j.nicl.2022.103205 · Cited by 58
Cervical spinal cord susceptibility-weighted MRI at 7T: application to multiple sclerosis
Clarke, M. A., Witt, A. A., Robison, R. K., Fleishman, S., Combes, A. J. E., Houston, D., Prock, L. E., Sweeney, G., O'Grady, K. P., McKnight, C. D., et al. (2023) · NeuroImage · doi:10.1016/j.neuroimage.2023.120460 · Cited by 21
“…of the CVS in the brain have found it to be detectable with different SWI sequences, at different field strengths and across scanning platforms (Samaraweera et al., 2017; Sinnecker et al., 2019) with optimized T2*-weighted sequences at 7T accepted as the gold-standard (Castellaro et al., 2020).”
Toljan, K., Amin, M., & Ontaneda, D. (2025) · Clinical Radiology · doi:10.1016/j.crad.2025.106984 · Cited by 9
Metadata
- Authors
- Castellaro, M., Tamanti, A., Pisani, A. I., Pizzini, F. B., Crescenzo, F., & Calabrese, M.
- Venue
- Diagnostics
- Publisher
- MDPI AG
- Published
- 2020-11-29
- Volume
- 10
- Issue
- 12
- Pages
- 1025
- ISSN
- 2075-4418 (ISSN-L)
- OpenAlex
- W3109117142
- Cited by
- 87
- References
- 11
- FWCI
- 1.98
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.