Novel Diagnostic Techniques for Rotating Electrical Machines—A Review
Open accessThe DOI matches its Crossref record; 126 of the 126 references it cites were found in a registry or an index.
Abstract
This paper aims to update the review of diagnostic techniques for rotating electrical machines of different type and size. Each of the main sections of the paper is focused on a specific component of the machine (stator and rotor windings, magnets, bearings, airgap, load and auxiliaries, stator and rotor laminated core) and divided into subsections when the characteristics of the component are different according to the type or size of the machine. The review considers both the techniques currently applied on field for the diagnostics of the electrical machines and the novel methodologies recently proposed by the researchers in the literature.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Moreover, as results from the dependence (3), other motor damages depending on the rotational speed, such as ITSCs (see (1)) and mechanical damages such as dynamic eccentricity, can be identified by the same frequencies in the stator currents [29], [32].”
From Fault Diagnosis and Fault-Tolerant Control of PMSM Drives–State of the Art and Future Challenges (2022) · cites this paper as [32]
In the citing paper
“Exceeding this limit adversely affects the bearing operation (increasing its wear) and increases the stress in the machine [32].”
From Fault Diagnosis and Fault-Tolerant Control of PMSM Drives–State of the Art and Future Challenges (2022) · cites this paper as [32]
In the citing paper
“Additionally, the FFT can even mask components that appear at a given moment of time but are of very short duration [10], [32].”
From Fault Diagnosis and Fault-Tolerant Control of PMSM Drives–State of the Art and Future Challenges (2022) · cites this paper as [32]
Citations
Cites
Rolling element bearing diagnostics—A tutorial
Randall, R. B., & Antoni, J. (2011) · Mechanical Systems and Signal Processing · doi:10.1016/j.ymssp.2010.07.017 · Cited by 2,744 · cited 1×
“A comprehensive review of this argument is described in [91], even if in recent years further variants of the vibration analysis have been proposed, as, for example, in [92].”
BackgroundDeep Learning Algorithms for Bearing Fault Diagnostics—A Comprehensive Review
Zhang, S., Zhang, S., Wang, B., & Habetler, T. G. (2020) · IEEE Access · doi:10.1109/access.2020.2972859 · Cited by 913 · cited 1×
“In [106], a very recent survey of these papers is reported, together with a comparative study of the classification accuracy of various algorithms that use the open-source Case Western Reserve University (CWRU) bearing dataset.”
BackgroundTrends in Fault Diagnosis for Electrical Machines: A Review of Diagnostic Techniques
Henao, H., Capolino, G.-A., Fernandez-Cabanas, M., Filippetti, F., Bruzzese, C., Strangas, E., Pusca, R., Estima, J., Riera-Guasp, M., & Hedayati-Kia, S. (2014) · IEEE Industrial Electronics Magazine · doi:10.1109/mie.2013.2287651 · Cited by 602 · cited 2×
“Insulation is one of the most fault-prone electrical machine components: for example, the proportion of stator winding insulation faults is between 21% and 40% of total faults in IMs, according to the type and dimension of the machine [8].”
BackgroundRiera-Guasp, M., Antonino-Daviu, J. A., & Capolino, G.-A. (2015) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2014.2375853 · Cited by 573 · cited 1×
“Hence, the techniques of the diagnosis of inter-turn short circuits must be able to detect them very fast, in their initial phase, when the fault current is still low or, at least, before the conventional protection system acts by interrupting the power supply [10].”
MethodRecent Advances in Modeling and Online Detection of Stator Interturn Faults in Electrical Motors
Gandhi, A., Corrigan, T., & Parsa, L. (2011) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2010.2089937 · Cited by 544 · cited 2×
“It is important to note that stator shorts are more dangerous for PMSMs, as they may cause magnetic field strengths greater than the coercivity of magnets, permanently demagnetizing the magnets [25].”
BackgroundFault Detection in Induction Machines Using Power Spectral Density in Wavelet Decomposition
Cusid�Cusido, J., Romeral, L., Ortega, J. A., Rosero, J. A., & Garc�aGarcia Espinosa, A. (2008) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2007.911960 · Cited by 512 · cited 3×
“The main problems examined i the literature are: (i) the pre ence of harmonics in the electromagnetic s gnals coming from the inverter, which diminishes the likelihood of fault detection; (ii) the compensation effect due to the control system, if the drive works in closed loop, which masks the effects induced by the f…”
BackgroundMethodGrubic, S., Aller, J. M., Lu, B., & Habetler, T. G. (2008) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2008.2004665 · Cited by 490 · cited 1×
“Important reviews of the methods for detecting on-line faults between stator turns in LV electrical motors are described in [24,25], especially regarding IMs and PMSMs.”
Deep Learning Based Approach for Bearing Fault Diagnosis
He, M., & He, D. (2017) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2017.2661250 · Cited by 484 · cited 1×
“However, there is another group of papers which is focused on machine learning (ML) and deep learning (DL) techniques [102]; to implement effective ML and DL algorithms for bearing fault detection, good data collection is needed and, therefore, these papers sometimes refer to datasets available on-line [103], but also…”
BackgroundDorrell, D. G., Thomson, W. T., & Roach, S. (1997) · IEEE Transactions on Industry Applications · doi:10.1109/28.567073 · Cited by 450
Detection and location of interturn short circuits in the stator windings of operating motors
Penman, J., Sedding, H. G., Lloyd, B. A., & Fink, W. T. (1994) · IEEE Transactions on Energy Conversion · doi:10.1109/60.368345 · Cited by 394 · cited 1×
“The first important work on this topic identified the following frequencies in the axial leakage flux [27]: ( n1 ± k1 1− s p ) fs = n1 fs ± k1 fr (1)”
BackgroundStatic-, Dynamic-, and Mixed-Eccentricity Fault Diagnoses in Permanent-Magnet Synchronous Motors
Ebrahimi, B. M., Faiz, J., & Roshtkhari, M. J. (2009) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2009.2029577 · Cited by 386 · cited 2×
“Concerning PMSMs, these frequencies have been recognized as typical of eccentricity (static, dynamic and mixed) [113,114]: [1± (2k− 1)/p] fs (21)”
BackgroundHenao, H., Demian, C., & Capolino, G.-A. (2003) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2003.816531 · Cited by 361 · cited 1×
“Later, in [26], the following set of frequencies was highlighted in the external stray flux: ( γ Nr p (1− s) ± ν ) fs (5)”
BackgroundCondition Monitoring of Rotating Electrical Machines
Tavner, P., Ran, L., Penman, J., & Sedding, H. (2008) · Institution of Engineering and Technology eBooks · doi:10.1049/pbpo056e · Cited by 331 · cited 1×
“The general problem of diagnostics is to detect whether or not a specific fault is present based on the available information, preferably without an intrusive inspection of the machine [12].”
BackgroundLeite, V. C. M. N., Borges da Silva, J. G., Veloso, G. F. C., Borges da Silva, L. E., Lambert-Torres, G., Bonaldi, E. L., & de Lacerda de Oliveira, L. E. (2015) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2014.2345330 · Cited by 274 · cited 1×
“Moreover, the fast kurtogram algorithm has been proved effective in identifying the frequency bands in which the fault impulses are concentrated [97].”
MethodEbrahimi, B. M., Javan Roshtkhari, M., Faiz, J., & Khatami, S. V. (2014) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2013.2263777 · Cited by 271 · cited 2×
“In [114], a new index is defined for static and dynamic eccentricity diagnostics in PMSMs; it is calculated through a linear combination of energy, shape factor, peak, head angle of the peak, area below the peak, gradient of the peak of the detail signals in wavelet decomposition and coefficients of the autoregressive…”
BackgroundMethodFrosini, L., Harlisca, C., & Szabo, L. (2015) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2014.2361115 · Cited by 264
Self-citationFrosini, L., & Bassi, E. (2010) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2009.2026770 · Cited by 254
Self-citationRuiz, J.-R. R., Rosero, J. A., Espinosa, A. G., & Romeral, L. (2009) · IEEE Transactions on Magnetics · doi:10.1109/tmag.2009.2015942 · Cited by 231
Advanced Diagnosis of Electrical Faults in Wound-Rotor Induction Machines
Gritli, Y., Zarri, L., Rossi, C., Filippetti, F., Capolino, G.-A., & Casadei, D. (2013) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2012.2236992 · Cited by 193 · cited 1×
“As explained in [80], a rotor dissymmetry produces an inverse rotating magnetic field and an inverse sequence component in the rotor currents at frequency sfs.”
BackgroundDiagnosis of Stator Inter-Turn Short Circuits in DTC Induction Motor Drives
Cruz, S. M. A., & Cardoso, A. J. M. (2004) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2004.834012 · Cited by 185
Bearing Fault Model for Induction Motor With Externally Induced Vibration
Immovilli, F., Bianchini, C., Cocconcelli, M., Bellini, A., & Rubini, R. (2013) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2012.2213566 · Cited by 181 · cited 2×
“Other typical frequencies have been defined in [90].”
BackgroundUrresty, J.-C., Riba, J.-R., Delgado, M., & Romeral, L. (2012) · IEEE Transactions on Energy Conversion · doi:10.1109/tec.2011.2176127 · Cited by 181 · cited 4×
“In [84], the early rotor demagnetization in a surface-mounted PMSM was detected through an on-line monitoring of the zero-sequence voltage component (ZSVC).”
BackgroundMethodInfluentialCurrent monitoring for detecting inter-turn short circuits in induction motors
Stavrou, A., Sedding, H. G., & Penman, J. (2001) · IEEE Transactions on Energy Conversion · doi:10.1109/60.911400 · Cited by 168
Nøland, J. K., Leandro, M., Suul, J. A., & Molinas, M. (2020) · IEEE Access · doi:10.1109/access.2020.3007791 · Cited by 154 · cited 1×
“Secondly, the world is becoming more and more electric [1] and therefore electrical machines are progressively more present in any application.”
BackgroundThomson, W. T. (2002) · IEEE International Electric Machines & Drives Conference (IEMDC) · doi:10.1109/iemdc.2001.939425 · Cited by 141 · cited 1×
“In the same year, another author pointed out a group of frequencies similar to (1) in the current spectrum [29]: (”
BackgroundFilippetti, F., Bellini, A., & Capolino, G. (2013) · 2013 IEEE Workshop on Electrical Machines Design, Control and Diagnosis (WEMDCD) · doi:10.1109/wemdcd.2013.6525180 · Cited by 128 · cited 6×
“In the first case, the WRIM may continue to operate, whereas in the event of short or open circuits, the operation is limited to a short period after the fault [53].”
BackgroundInfluentialMonitoring of induction motor load by neural network techniques
Salles, G., Filippetti, F., Tassoni, C., Crellet, G., & Franceschini, G. (2000) · IEEE Transactions on Power Electronics · doi:10.1109/63.849047 · Cited by 128 · cited 1×
“where fo is the fundamental frequency of the torque ripple [117].”
BackgroundStator-Current Spectrum Signature of Healthy Cage Rotor Induction Machines
Joksimovic, G. M., Riger, J., Wolbank, T. M., Peric, N., & Vasak, M. (2013) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2012.2236995 · Cited by 125 · cited 1×
“The implementation of this methodology must take into account that the current spectrum of a healthy motor always contains harmonic components, which are exhaustively described in [32] for a SCIM.”
MethodKia, S. H., Henao, H., & Capolino, G.-A. (2015) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2014.2360068 · Cited by 116 · cited 1×
“To overcome this problem, in [122], a noninvasive approach for the detection of gear tooth surface damage faults, focused on the stator current space vector analysis, is investigated, providing good results.”
Park, Y., Fernandez, D., Lee, S. B., Hyun, D., Jeong, M., Kommuri, S. K., Cho, C., Diaz Reigosa, D., & Briz, F. (2019) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2018.2886772 · Cited by 116 · cited 1×
“In [88], the Hall sensors already existing in an interior PMSM for its control are employed to measure the flux variation inside the machine caused by a magnetic asymmetry of the rotor; FEM analysis and experimental tests demonstrate that this technique may permit a correct diagnosis of local demagnetization and dynam…”
MethodDetection of Broken Outer-Cage Bars for Double-Cage Induction Motors Under the Startup Transient
Daviu, J. A. A., Riera‐Guasp, M., Pons-Llinares, J., Park, J., Lee, S. B., Yoo, J., & Kral, C. (2012) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2012.2210173 · Cited by 112 · cited 2×
“Precisely, the left sideband during the starting is examined in [61], while in [62], both sidebands are analyzed during a general transient.”
BackgroundMethodElectrical machines fault diagnosis by stray flux analysis
Romary, R., Pusca, R., Lecointe, J., & Brudny, J. F. (2013) · IEEE Workshop on Electrical Machines Design, Control and Diagnosis · doi:10.1109/wemdcd.2013.6525184 · Cited by 111 · cited 1×
“and the following multiples in the external stray flux [31]:”
BackgroundMirzaeva, G., & Saad, K. (2018) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2018.2821098 · Cited by 107
Modern Diagnostics Techniques for Electrical Machines, Power Electronics, and Drives
Capolino, G.-A., Antonino-Daviu, J. A., & Riera-Guasp, M. (2015) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2015.2391186 · Cited by 104
Online Stator Interturn Short Circuits Monitoring in the DFOC Induction-Motor Drive
Wolkiewicz, M., Tarchala, G., Orlowska-Kowalska, T., & Kowalski, C. T. (2016) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2016.2520902 · Cited by 104 · cited 2×
“An uncontrolled growth in the damage degree can lead to unstable operation of the drive [16,17].”
BackgroundRotor Speed-Based Bearing Fault Diagnosis (RSB-BFD) Under Variable Speed and Constant Load
Hamadache, M., Lee, D., & Veluvolu, K. C. (2015) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2015.2416673 · Cited by 103 · cited 1×
“In [98], a method based on rotor speed signal was proposed, which is advantageous in terms of cost and simplicity.”
MethodPanagiotou, P. A., Arvanitakis, I., Lophitis, N., Daviu, J. A. A., & Gyftakis, K. N. (2019) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2019.2905803 · Cited by 101 · cited 1×
“A recent study is presented in [66,67], which deals with broken bar detection in large IMs, where the sideband components are usually located near the fundamental frequency, owing to the low value of slip at steady state.”
BackgroundReliable Detection of Induction Motor Rotor Faults Under the Rotor Axial Air Duct Influence
Yang, C., Kang, T.-J., Hyun, D., Lee, S. B., Daviu, J. A. A., & Pons-Llinares, J. (2014) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2013.2297448 · Cited by 95
Irhoumah, M., Pusca, R., Lefèvre, É., Mercier, D., Romary, R., & Demian, C. (2017) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2017.2745408 · Cited by 95 · cited 1×
“An upgrading of this technique is described in [35,36], where a statistical procedure is shown to detect stator winding short circuits in IMs and SMs: it requires the computation of a correlation coefficient achieved by examining the evolution of magnetic flux harmonics collected in the motor case at no load and in lo…”
MethodRamirez-Nunez, J. A., Daviu, J. A. A., Climente-Alarcón, V., Quijano-López, A., Razik, H., Osornio-Rios, R. A., & Romero-Troncoso, R. D. J. (2018) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2018.2843371 · Cited by 95 · cited 1×
“The feasibility of the stray flux analysis during the start-up of an IM has been investigated in [69], to detect two types of faults (broken bars and misalignment), even when they coexist.”
BackgroundA Data-Driven Approach for Bearing Fault Prognostics
Jin, X., Que, Z., Sun, Y., Guo, Y., & Qiao, W. (2019) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2019.2907666 · Cited by 95
Gas turbine engine prognostics using Bayesian hierarchical models: A variational approach
Zaidan, M. A., Mills, A. R., Harrison, R. F., & Fleming, P. J. (2015) · Mechanical Systems and Signal Processing · doi:10.1016/j.ymssp.2015.09.014 · Cited by 91
Bayesian Hierarchical Models for aerospace gas turbine engine prognostics
Zaidan, M. A., Harrison, R. F., Mills, A. R., & Fleming, P. J. (2014) · Expert Systems with Applications · doi:10.1016/j.eswa.2014.08.007 · Cited by 89
Wavelet‐based real‐time stator fault detection of inverter‐fed induction motor
Vinayak, B. A., Anjali Anand, K., & Jagadanand, G. (2019) · IET Electric Power Applications · doi:10.1049/iet-epa.2019.0273 · Cited by 86 · cited 1×
“In [50], a real-time procedure is presented for the early detection of stator shorts between turns in an IM supplied by a voltage source inverter (VSI).”
MethodBrushless Three-Phase Synchronous Generator Under Rotating Diode Failure Conditions
Salah, M., Bacha, K., Châari, A., & Benbouzid, M. (2014) · IEEE Transactions on Energy Conversion · doi:10.1109/tec.2014.2312173 · Cited by 83 · cited 2×
“When this device is no incorporated in the SM, alter ative methods can be applied, based on the output v ltage analysis [54] r on the total harmonic distort on (THD) and p larity of the synch onous exciter armature current [55].”
MethodExperience With Online Partial-Discharge Measurement in High-Voltage Inverter-Fed Motors
Stone, G. C., Sedding, H. G., & Chan, C. (2017) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2017.2740280 · Cited by 80 · cited 1×
“In [21], a method was proposed to measure the stator winding PDs during the operation of medium-voltage motors fed from PWM drives.”
MethodZamudio-Ramírez, I., Daviu, J. A. A., Osornio-Rios, R. A., Romero-Troncoso, R. D. J., & Razik, H. (2019) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2019.2931274 · Cited by 80 · cited 1×
“In [83], a novel approach is introduced to detect rotor asymmetry faults in a WRIM, based on the measurement of the stray flux in three different positions.”
Park, Y., Choi, H., Shin, J., Park, J., Lee, S. B., & Jo, H. (2020) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2019.2962470 · Cited by 77 · cited 1×
“A very recent paper, [111], starts with the considerations that: (i) often it is not possible to distinguish rotor eccentricity and load defects; (ii) false rotor cage fault indications are frequent; (iii) a new trend aims to integrate smart self-diagnostics into electrical machines by means of embedded sensors, espec…”
BackgroundRomero-Troncoso, R. D. J., García-Pérez, A., Moríñigo-Sotelo, D., Duque-Pérez, Ó., Osornio-Rios, R. A., & Ibarra-Manzano, M.-A. (2016) · Electric Power Systems Research · doi:10.1016/j.epsr.2015.12.009 · Cited by 76 · cited 1×
“An approach based on the combination of complete ensemble empirical mode decomposition (CEEMD) and the multiple signal classification (MUSIC) is presented in [72]; it was applied to the stator current of an inverter-fed IM during a starting transient followed by a steady-state period and”
MethodConcari, C., Franceschini, G., & Tassoni, C. (2008) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2008.2003212 · Cited by 75 · cited 1×
“In [70], an approach focused on the analysis of the axial vibrations, arising in the presence of inter-bar currents, is proposed in combination with MCSA to overcome the problems due to the inter-bar currents in detecting broken rotor bars.”
BackgroundMagnets faults characterization for Permanent Magnet Synchronous Motors
Casadei, D., Filippetti, F., Rossi, C., & Stefani, A. (2009) · 2009 IEEE International Symposium on Diagnostics for Electric Machines, Power Electronics and Drives · doi:10.1109/demped.2009.5292770 · Cited by 74 · cited 2×
“Some research revealed that partial demagnetization produces harmonic components in the stator currents at the following frequencies [84,86,87]:”
BackgroundSalah, A. A., Dorrell, D. G., & Guo, Y. G. (2019) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2019.2892359 · Cited by 72 · cited 3×
“and further harmonics excited by eccentricity in the vibration spectrum at frequencies [108,109]:”
BackgroundIrhoumah, M., Pusca, R., Lefèvre, É., Mercier, D., & Romary, R. (2019) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2019.2899560 · Cited by 67 · cited 1×
“An upgrading of this technique is described in [35,36], where a statistical procedure is shown to detect stator winding short circuits in IMs and SMs: it requires the computation of a correlation coefficient achieved by examining the evolution of magnetic flux harmonics collected in the motor case at no load and in lo…”
MethodTozz, M., Cavallini, A., & Montanari, G. C. (2010) · IEEE Electrical Insulation Magazine · doi:10.1109/mei.2010.5511185 · Cited by 65 · cited 1×
“First of all, it is significant to note that, though with a sinusoidal power supply the winding insulation of LV machines does not experience PDs, they can occur if these machines are driven by inverters; hence, the monitoring and testing of an inverter-fed LV machine should be performed according to IEC 60034-18-41,…”
MethodA Method for Online Stator Insulation Prognosis for Inverter-Driven Machines
Jensen, W. R., Strangas, E. G., & Foster, S. N. (2018) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2018.2854408 · Cited by 64 · cited 1×
“Prognostics may be used to evaluate the rate of degradation and may permit the machine to continue to operate regularly until the moment of failure; it may diminish unnecessary expensive maintenance and unexpected failures [4].”
BackgroundKim, H., Lee, S. B., Park, S., Kia, S. H., & Capolino, G. (2015) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2015.2508423 · Cited by 59 · cited 2×
“For an IM, the mechanical load oscillations (fr/r) are transmitted to the motor rotor across the coupling and revealed in the stator current at frequencies [64,65]:”
BackgroundMethodEfficient digital signal processing techniques for induction machines fault diagnosis
Kia, S. H., Henao, H., & Capolino, G. (2013) · IEEE Workshop on Electrical Machines Design, Control and Diagnosis · doi:10.1109/wemdcd.2013.6525183 · Cited by 57 · cited 1×
“For this purpose, novel signal analysis techniques have been suggested in [33].”
MethodGritli, Y., Lee, S. B., Filippetti, F., & Zarri, L. (2013) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2013.2285958 · Cited by 55
Stator Fault Detection on DTC-Driven IM via Magnetic Signatures Aided by 2-D FEA Co-Simulation
Eldeeb, H. H., Berzoy, A., & Mohammed, O. A. (2019) · IEEE Transactions on Magnetics · doi:10.1109/tmag.2019.2892707 · Cited by 55 · cited 1×
“An update to this study investigates the stray radiated magnetic field measured around the same motor through a magnetic loop antenna at different distances and angles, to examine its influence on the diagnostics of stator shorts [49].”
BackgroundStator-Interlaminar-Fault Detection Using an External-Flux-Density Sensor
Romary, R., Jelassi, S., & Brudny, J. F. (2009) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2009.2029525 · Cited by 52 · cited 1×
“In [126,127], the proposal starts from the consideration that surface currents caused by a short circuit between laminations have a significant influence on the external magnetic field; therefore, an on-line diagnostic technique based on the analysis of the external magnetic field was theoretically and experimentally…”
MethodStrangas, E. G., Aviyente, S., Neely, J. D., & Zaidi, S. S. H. (2013) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2012.2227913 · Cited by 51 · cited 1×
“A further evolution of diagnostics (or diagnosis) is prognostics (or prognosis); diagnostics consist in identifying the fault that will lead to a failure and estimating its severity, while prognostics rely on continuous monitoring of the variables and parameters of the system and use this information to predict the ti…”
BackgroundMonitoring of Rotor-Bar Defects in Inverter-Fed Induction Machines at Zero Load and Speed
Wolbank, T., Nussbaumer, P., Chen, H., & Macheiner, P. E. (2010) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2010.2068533 · Cited by 50 · cited 1×
“A method based on the standard current sensors already existing in modern industrial inverters is proposed in [71] to identify rotor bar defects at no load and almost at standstill.”
MethodSchmidt, S. P., Heyns, P. S., & Gryllias, K. (2018) · Mechanical Systems and Signal Processing · doi:10.1016/j.ymssp.2018.06.026 · Cited by 50 · cited 1×
“A comprehensive review of this argument is described in [91], even if in recent years further variants of the vibration analysis have been proposed, as, for example, in [92].”
BackgroundState of the Art on Stray Flux Analysis in Faulted Electrical Machines
Capolino, G.-A., Romary, R., Henao, H., & Pusca, R. (2019) · 2019 IEEE Workshop on Electrical Machines Design, Control and Diagnosis (WEMDCD) · doi:10.1109/wemdcd.2019.8887805 · Cited by 49 · cited 3×
“In recent years, traditional diagnostic techniques, based on the vibration measurement, have been progr ssively abandon in favor f the a alysis of electromagnetic signals, in particular the stator current and the external stray flux around the motor [11].”
BackgroundMethodInfluentialAsad, B., Vaimann, T., Belahcen, A., & Kallaste, A. (2018) · International Conference on Electrical Machines (ICEM) · doi:10.1109/icelmach.2018.8506957 · Cited by 48 · cited 1×
“In [76], three types of analysis (FFT, Hilbert transform and modulus of Park’s vector) are implemented on the current signals coming from an IM driven by an inverter at nominal load and with broken bars, and an evaluation of the effectiveness of these methods is shown.”
MethodOffline and Online Methods for Stator Core Fault Detection in Large Generators
Romary, R., Demian, C., Schlupp, P., & Roger, J. (2012) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2012.2224077 · Cited by 46 · cited 1×
“In [126,127], the proposal starts from the consideration that surface currents caused by a short circuit between laminations have a significant influence on the external magnetic field; therefore, an on-line diagnostic technique based on the analysis of the external magnetic field was theoretically and experimentally…”
MethodAirgap Search Coil-Based Detection of Damper Bar Failures in Salient Pole Synchronous Motors
Yun, J., Park, S. W., Yang, C., Lee, S. B., Daviu, J. A. A., Šašić, M., & Stone, G. C. (2019) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2019.2912148 · Cited by 46 · cited 2×
“Several cases of broken damper bars in SMs have recently been reported in the literature [56].”
BackgroundMethodMuetze, A., & Strangas, E. G. (2016) · IEEE Industry Applications Magazine · doi:10.1109/mias.2015.2459117 · Cited by 45 · cited 1×
“In other words, prognostics aim to forecast the evolution of a fault and to predict when the machine will no longer operate as designed or desired [3].”
BackgroundKia, S. H., Henao, H., & Capolino, G. (2012) · International Conference on Electrical Machines (ICEM) · doi:10.1109/icelmach.2012.6350079 · Cited by 40 · cited 1×
“Nevertheless, in [121], a comparative study of vibration, acoustic pressure and stator current analysis abilities is proposed for the diagnosis of a gear tooth wear fault and is tested on a 250 W SCIM shaft connected to a single-stage gearbox.”
BackgroundDetection of stator winding insulation failures: On-line and off-line tests
Cabanas, M. F., Norniella, J. G., Melero, M. G., Rojas, C. H., Cano, J. M., Pedrayes, F., & Orcajo, G. A. (2013) · IEEE Workshop on Electrical Machines Design, Control and Diagnosis · doi:10.1109/wemdcd.2013.6525181 · Cited by 34 · cited 2×
“From the interesting reviews of these techniques described in [19,20], it arises that the tan delta and PD measurements may not provide a correct diagnosis of the insulation conditions for machines with voltages lower than 6 kV.”
BackgroundCherif, H., Menacer, A., Romary, R., & Pusca, R. (2017) · IEEE International Symposium on Diagnostics for Electrical Machines, Power Electronics and Drives (SDEMPED) · doi:10.1109/demped.2017.8062341 · Cited by 32 · cited 1×
“This technique is based on the computation of the energy of the detail decomposition in a healthy condition and during a short circuit [34].”
MethodOn the identification of the angular position of gears for the diagnostics of planetary gearboxes
D’Elia, G., Mucchi, E., & Cocconcelli, M. (2016) · Mechanical Systems and Signal Processing · doi:10.1016/j.ymssp.2016.06.016 · Cited by 31 · cited 1×
“Similarly to bearings, even the diagnostics of the gearbox are mainly handled through the vibration analysis, as, for example, in [120].”
Afshar, M., Tabesh, A., Ebrahimi, M., & Khajehoddin, S. A. (2019) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2019.2963295 · Cited by 31 · cited 1×
“A particular machine is considered in [51], i.”
BackgroundRotor inter-turn short circuit fault detection in wound rotor induction machines
Yazidi, A., Henao, H., Capolino, G., & Bétin, F. (2010) · International Conference on Electrical Machines (ICEM) · doi:10.1109/icelmach.2010.5607929 · Cited by 30 · cited 1×
“A method to identify a rotor short circuit between turns in a WRIM operating as a generator, through spectral and bispectral analysis, is described in [78].”
MethodA Stator-Core Quality-Assessment Technique for Inverter-Fed Induction Machines
Lee, K., Hong, J., Lee, K., Lee, S. B., & Wiedenbrug, E. J. (2009) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2009.2036527 · Cited by 28 · cited 1×
“In [125], a methodology applicable to inverter-fed IMs without disassembly is suggested, focused on the measurement and calculation of the input power as a function of flux vector angle, which reveals a different trend in the case of a healthy and faulty stator core.”
MethodRzeszuciński, P., Orman, M., Pinto, C. T., Tkaczyk, A., & Sułowicz, M. (2018) · IEEE Industry Applications Magazine · doi:10.1109/mias.2017.2740463 · Cited by 28 · cited 1×
“In [99], rolling bearing faults were detected by means of the acoustic signal collected with a mobile phone.”
BackgroundA Data-Driven Approach for Bearing Fault Prognostics
Jin, X., Que, Z., Sun, Y., Guo, Y., & Qiao, W. (2018) · IEEE Industry Applications Society Annual Meeting (IAS) · doi:10.1109/ias.2018.8544586 · Cited by 28
Reigosa, D., Fernández, D., Martinez, M., Park, Y., Lee, S. B., & Briz, F. (2019) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2019.2914892 · Cited by 28 · cited 1×
“Furthermore, the same research group proposed the zero-sequence component of the magnetic flux density to detect demagnetization [89].”
BackgroundMonitoring and Diagnostics of Electrical Machines and Drives: a State of the Art
Frosini, L. (2019) · IEEE Workshop on Electrical Machines Design, Control and Diagnosis · doi:10.1109/wemdcd.2019.8887815 · Cited by 28 · cited 2×
“Generally, diagnostics through the measurement of electromagnetic signals are heavily influ nced by the p wer sup ly of the electronically commutated machines [13].”
BackgroundSelf-citationToward Practical Quantification of Induction Drive Mixed Eccentricity
Concari, C., Franceschini, G., & Tassoni, C. (2011) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2011.2124434 · Cited by 27 · cited 1×
“In addition, in [110], the coexistence of static and dynamic eccentricities in IMs was evaluated and a novel fault severity index for mixed eccentricity was developed, based on the stator current harmonic components.”
MethodNegative sequence current compensation for stator shorted turn detection in induction motors
Bakhri, S., Ertuğrul, N., & Soong, W. L. (2012) · Annual Conference of the IEEE Industrial Electronics Society (IECON) · doi:10.1109/iecon.2012.6388908 · Cited by 26 · cited 1×
“A disadvantage of the methods based on this analysis is that other causes may induce a negative sequence component in the current, for example, imbalanced supply voltages or constructive asymmetries [38].”
MethodDrif, M., Kim, H., Kim, J., Lee, S. B., & Cardoso, A. J. M. (2016) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2016.2613508 · Cited by 26 · cited 2×
“For an IM, the mechanical load oscillations (fr/r) are transmitted to the motor rotor across the coupling and revealed in the stator current at frequencies [64,65]:”
BackgroundMethodA wavelet-based technique to detect stator faults in inverter-fed induction motors
Frosini, L., Zanazzo, S., & Albini, A. (2016) · International Conference on Electrical Machines (ICEM) · doi:10.1109/icelmach.2016.7732938 · Cited by 26 · cited 1×
“In [45], a WT-based pre-processing method proved effective in filtering the stator current and stray flux signals in order to diagnose stator shorts in an IM supplied by an electronic converter, through the typical harmonics of this fault.”
MethodSelf-citationMoosavi, S. M. M., Faiz, J., Abadi, M. B., & Cruz, S. M. A. (2019) · IET Electric Power Applications · doi:10.1049/iet-epa.2018.5528 · Cited by 25 · cited 1×
“In [82], the effects of rotor inter-turn shorts and imbalanced rotor resistance on fault indicators were evaluated.”
BackgroundFault Diagnosis of Rotating Rectifier Based on Waveform Distortion and Polarity of Current
Wei, Z., Liu, W., Pang, J., Sun, C., Zhang, Z., & Ma, P. (2019) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2019.2893140 · Cited by 25 · cited 2×
“When this device is no incorporated in the SM, alter ative methods can be applied, based on the output v ltage analysis [54] r on the total harmonic distort on (THD) and p larity of the synch onous exciter armature current [55].”
MethodMuxiri, A. C. P., Bento, F., Fonseca, D. S. B., & Cardoso, A. J. M. (2019) · International Conference on Industrial Engineering, Applications and Manufacturing (ICIEAM) · doi:10.1109/icieam.2019.8743076 · Cited by 25 · cited 1×
“The proposal to use a thermographic analysis is evaluated in [43] by means of a finite element method (FEM) simulation, considering that a substantial increment of the temperature in the stator windings is experienced when an inter-turn short circuit occurs.”
MethodThe Role of the Mechanical Speed Frequency on the Induction Motor Fault Detection via the Stray Flux
Gyftakis, K. N., Panagiotou, P. A., & Lee, S. B. (2019) · IEEE International Symposium on Diagnostics for Electrical Machines, Power Electronics and Drives (SDEMPED) · doi:10.1109/demped.2019.8864863 · Cited by 25 · cited 1×
“Further investigations on the diagnostic capability of the stray flux to detect rotor faults are reported in [68], showing that the mechanical frequency-associated harmonics can be purely related to broken bars and totally independent from rotor eccentricity and rotor imbalance.”
BackgroundCondition Assessment of Electrical Apparatus With EMI Diagnostics
Timperley, J. E., & Vallejo, J. M. (2016) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2016.2603467 · Cited by 24
Daviu, J. A. A., Fuster-Roig, V., Park, S., Park, Y., Choi, H., Park, J., & Lee, S. B. (2020) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2020.2965903 · Cited by 24 · cited 1×
“In [57,58], two further methodologies for identifying damper bar faults in salient pole SMs without disassembly have been proposed.”
MethodPanagiotou, P. A., Arvanitakis, I., Lophitis, N., Daviu, J. A. A., & Gyftakis, K. N. (2019) · IET Electric Power Applications · doi:10.1049/iet-epa.2018.5512 · Cited by 23 · cited 1×
“A recent study is presented in [66,67], which deals with broken bar detection in large IMs, where the sideband components are usually located near the fundamental frequency, owing to the low value of slip at steady state.”
BackgroundEldeeb, H. H., Berzoy, A., & Mohammed, O. A. (2018) · International Conference on Electrical Machines (ICEM) · doi:10.1109/icelmach.2018.8507251 · Cited by 22 · cited 1×
“In [48], an analysis of the stator current and torque in the frequency domain for a direct torque control (DTC)-driven IM shows that inter-turn shorts cause numerous harmonic components in these signals and even inter-harmonic components that mimic or mask the typical signatures of a DOL faulty IM; this happens due to…”
BackgroundFeature Engineering for Ball Bearing Combined-Fault Detection and Diagnostic
Khlaief, A., Nguyen, K. T. P., Medjaher, K., Picot, A., Maussion, P., Tobon, D., Chauchat, B., & Cheron, R. (2019) · IEEE International Symposium on Diagnostics for Electrical Machines, Power Electronics and Drives (SDEMPED) · doi:10.1109/demped.2019.8864899 · Cited by 21 · cited 1×
“However, there is another group of papers which is focused on machine learning (ML) and deep learning (DL) techniques [102]; to implement effective ML and DL algorithms for bearing fault detection, good data collection is needed and, therefore, these papers sometimes refer to datasets available on-line [103], but also…”
BackgroundFault detection in inverter-fed induction motors in transient regime: State of the art
Fernandez-Cavero, V., Moríñigo-Sotelo, D., Duque-Pérez, Ó., & Pons-Llinares, J. (2015) · IEEE International Symposium on Diagnostics for Electrical Machines, Power Electronics and Drives (SDEMPED) · doi:10.1109/demped.2015.7303691 · Cited by 19 · cited 1×
“, the start-up [47]; in particular, the Hilbert–Huang transform results is suitable for non-stationary and non-linear signals and the adaptive slope transform allows for a better adaptation to the time-varying harmonic content of the signal.”
BackgroundDetection of stator core faults in large electrical machines
Bertenshaw, D. R., Smith, A. C., Ho, C.-Y., Chan, T., & Šašić, M. (2012) · IET Electric Power Applications · doi:10.1049/iet-epa.2011.0125 · Cited by 19 · cited 1×
“If this damage is unattended, it can spread and cause, in extreme cases, catastrophic failure of the machine [124].”
BackgroundJeong, M., Yun, J., Park, Y., Lee, S. B., & Gyftakis, K. N. (2018) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2018.2805828 · Cited by 19 · cited 2×
“, porosity or blowholes, which may worsen the performance and reliability of the motor [59].”
BackgroundHandbook of Large Turbo‐Generator Operation and Maintenance
Kerszenbaum, I., & Klempner, G. (2018) · Wiley eBooks · doi:10.1002/9781119390718 · Cited by 19
Fault detection based on closed-loop signals for induction machines
Zarri, L., Gritli, Y., Rossi, C., Bellini, A., & Filippetti, F. (2015) · IEEE Workshop on Electrical Machines Design, Control and Diagnosis · doi:10.1109/wemdcd.2015.7194539 · Cited by 18 · cited 2×
“The main problems examined i the literature are: (i) the pre ence of harmonics in the electromagnetic s gnals coming from the inverter, which diminishes the likelihood of fault detection; (ii) the compensation effect due to the control system, if the drive works in closed loop, which masks the effects induced by the f…”
BackgroundBlödt, M., Régnier, J., Chabert, M., & Faucher, J. (2006) · IET International Conference on Power Electronics, Machines and Drives (PEMD) · doi:10.1049/cp:20060072 · Cited by 18 · cited 1×
“As regards the possibility of detecting torque oscillations in IMs powered by inverters, an interesting, although complex, approach is presented in [118]; the stator current and the torque are measured and three fault indicators are calculated through the Wigner distribution and the instantaneous frequency estimation;…”
MethodBearing Faults Classification Based on Variational Mode Decomposition and Artificial Neural Network
Guedidi, A., Guettaf, A., Cardoso, A. J. M., Laala, W., & Arif, A. (2019) · IEEE International Symposium on Diagnostics for Electrical Machines, Power Electronics and Drives (SDEMPED) · doi:10.1109/demped.2019.8864830 · Cited by 18 · cited 1×
“However, there is another group of papers which is focused on machine learning (ML) and deep learning (DL) techniques [102]; to implement effective ML and DL algorithms for bearing fault detection, good data collection is needed and, therefore, these papers sometimes refer to datasets available on-line [103], but also…”
BackgroundMonitoring of Wound Rotor Induction Machines by Means of Discrete Wavelet Transform
Kia, S. H. (2018) · Electric Power Components and Systems · doi:10.1080/15325008.2018.1562647 · Cited by 17 · cited 1×
“In [81], a DWT-based slip-independent technique for detecting stator and rotor asymmetries in WRIMs is presented.”
MethodA new diagnostic instrument to detect generalized roughness in rolling bearings for induction motors
Frosini, L., Magnaghi, M., Albini, A., & Magrotti, G. (2015) · IEEE International Symposium on Diagnostics for Electrical Machines, Power Electronics and Drives (SDEMPED) · doi:10.1109/demped.2015.7303696 · Cited by 15 · cited 1×
“Although ideally these harmonics are not present in the event of generalized roughness, the analysis of stator current and external stray flux has been assessed to identify this type of fault in rolling bearings, with promising results [95].”
BackgroundSelf-citationNovel Method for Direct Measurement of Air Gap Anomalies in Direct-Drive Electrical Motors
Herman, J., Beguš, S., Mihalic, P., & Bojkovski, J. (2019) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2019.2905832 · Cited by 14 · cited 1×
“Always with reference to PMSMs, a recent paper considers in-wheel motors for automotive machines and proposes a new method to directly measure the airgap width, in either static or dynamic eccentricity, through an optical sensor integrated in the airgap, which acquires the reflection of the infrared radiation between…”
MethodMultiple faults detection in low voltage inverter-fed induction motors
Frosini, L., Minervini, M., Ciceri, L., & Albini, A. (2019) · IEEE International Symposium on Diagnostics for Electrical Machines, Power Electronics and Drives (SDEMPED) · doi:10.1109/demped.2019.8864885 · Cited by 14 · cited 2×
“Another purpose of this group of papers is to discriminate a bearing fault in the event of the coexistence of multiple faults [46].”
BackgroundMethodSelf-citationBroken Rotor Bar Fault Diagnosis in Induction Motors Using a Goertzel Algorithm
Spyropoulos, D. V., Mitronikas, E. D., & Dermatas, E. (2018) · International Conference on Electrical Machines (ICEM) · doi:10.1109/icelmach.2018.8506726 · Cited by 13 · cited 1×
“Another appropriate methodology for broken bar diagnosis in both DOL and inverter-fed IMs is founded on the Goertzel algorithm [77].”
MethodInduction Motors Torque Analysis via Frequency Extraction for Reliable Broken Rotor Bar Detection
Gyftakis, K. N., Spyropoulos, D. V., Arvanitakis, I., Panagiotou, P. A., & Mitronikas, E. D. (2020) · International Conference on Electrical Machines (ICEM) · doi:10.1109/icem49940.2020.9270825 · Cited by 13 · cited 1×
“rotors and diagnosis under light load or no load [60].”
BackgroundDiagnosis of Stator Faults in Synchronous Generators: Short Review and Practical Case
Verginadis, D., Daviu, J. A. A., Karlis, A. D., & Danikas, M. G. (2020) · International Conference on Electrical Machines (ICEM) · doi:10.1109/icem49940.2020.9270936 · Cited by 13 · cited 1×
“From the interesting reviews of these techniques described in [19,20], it arises that the tan delta and PD measurements may not provide a correct diagnosis of the insulation conditions for machines with voltages lower than 6 kV.”
BackgroundMartinez-Montes, E., Chillarón, L. J., Gilabert-Marzal, J., Daviu, J. A. A., & Quijano-López, A. (2018) · International Conference on Electrical Machines (ICEM) · doi:10.1109/icelmach.2018.8507224 · Cited by 12
Automated Bearing Fault Detection via Long Short-Term Memory Networks
Immovilli, F., Lippi, M., & Cocconcelli, M. (2019) · IEEE International Symposium on Diagnostics for Electrical Machines, Power Electronics and Drives (SDEMPED) · doi:10.1109/demped.2019.8864866 · Cited by 12 · cited 1×
“However, there is another group of papers which is focused on machine learning (ML) and deep learning (DL) techniques [102]; to implement effective ML and DL algorithms for bearing fault detection, good data collection is needed and, therefore, these papers sometimes refer to datasets available on-line [103], but also…”
BackgroundKeravand, M., Faiz, J., Soleimani, M., Ghasemi‐Bijan, M., Abadi, M. B., & Cruz, S. M. A. (2017) · IEEE International Symposium on Diagnostics for Electrical Machines, Power Electronics and Drives (SDEMPED) · doi:10.1109/demped.2017.8062364 · Cited by 11 · cited 1×
“For the monitoring of a WRIM, even the rotor current can be measured and, therefore, in [41], a method focused on FFT and WT of the rotor current is evaluated to identify stator shorts between turns.”
MethodGarcía-Pérez, A., Romero-Troncoso, R. D. J., Camarena‐Martinez, D., Osornio-Rios, R. A., & Amézquita-Sánchez, J. P. (2017) · IEEE International Symposium on Diagnostics for Electrical Machines, Power Electronics and Drives (SDEMPED) · doi:10.1109/demped.2017.8062368 · Cited by 10 · cited 1×
“Another technique to diagnose broken bars in IMs supplied by inverters during non-stationary regimes is proposed in [74]; it is based on the combination of two methods, time-corrected instantaneous frequency and a spectrogram, and it is called “reassigned spectrogram”.”
MethodYe, M., & Huang, J. E. (2018) · International Conference on Electrical Machines (ICEM) · doi:10.1109/icelmach.2018.8506849 · Cited by 10 · cited 1×
“In [101], a new diagnostic technique for PMSMs is presented; it is based on a speed sensorless observer, which aims to acquire the rotor angle and speed.”
MethodEmbedded System to Detect Bearing Faults in Line-Connected Induction Motors
Gongora, W. S., Goedtel, A., Castoldi, M. F., da Silva, S. A. O., & da Silva, I. N. (2018) · International Conference on Electrical Machines (ICEM) · doi:10.1109/icelmach.2018.8506865 · Cited by 9 · cited 1×
“In [100], a different technique for bearing diagnosis in DOL IMs is investigated, based on the voltage and current signals in the time domain; a neural network scheme is proven to be capable of identifying bearing failures by examining a half-cycle sampling of the IM supply voltages and stator currents.”
MethodDetection of Broken Rotor Bars Faults in Inverter-Fed Induction Motors
Godoy, W. F., da Silva, I. N., Goedtel, A., Palácios, R. H. C., Scalassara, P. R., Moríñigo-Sotelo, D., & Duque-Pérez, Ó. (2018) · International Conference on Electrical Machines (ICEM) · doi:10.1109/icelmach.2018.8506838 · Cited by 9 · cited 1×
“A novel technique to identify broken bars in an IM powered by three different types of inverter is focused on the amplitude of the stator current in the time domain [75].”
MethodZarate, S., Almandoz, G., Ugalde, G., Poza, J., & Escalada, A. J. (2018) · International Conference on Electrical Machines (ICEM) · doi:10.1109/icelmach.2018.8506755 · Cited by 9 · cited 1×
“Demagnetization has been recognized as one of the main causes for PMSM failure, because it induces a flux disturbance, which modifies several parameters of the machine [53,85].”
BackgroundRedondo, M., Platero, C. A., & Gyftakis, K. N. (2017) · IEEE International Symposium on Diagnostics for Electrical Machines, Power Electronics and Drives (SDEMPED) · doi:10.1109/demped.2017.8062343 · Cited by 8 · cited 1×
“For example, in [39], the voltage transformers usually installed for a multifunction protection relays in an SM are employed to detect shorts between turns.”
BackgroundObeid, N. H., Battiston, A., Boileau, T., & Nahid‐Mobarakeh, B. (2017) · IEEE International Symposium on Diagnostics for Electrical Machines, Power Electronics and Drives (SDEMPED) · doi:10.1109/demped.2017.8062352 · Cited by 8 · cited 1×
“in [37] to identify an intermittent inter-turn fault in a PMSM that induces particular distortions in the stator currents and reference voltages.”
BackgroundDetection of broken rotor bars in non-linear startups of inverter-fed induction motors
Fernandez-Cavero, V., Pons-Llinares, J., Duque-Pérez, Ó., & Moríñigo-Sotelo, D. (2019) · IEEE International Symposium on Diagnostics for Electrical Machines, Power Electronics and Drives (SDEMPED) · doi:10.1109/demped.2019.8864846 · Cited by 8 · cited 1×
“A further improvement of the time–frequency analysis is presented in [73], where the Dragon Transform, applied to the stator current of an IM with a broken bar, represents the harmonic evolutions as very thin lines.”
MethodGritli, Y., Zarri, L., Mengoni, M., Rossi, C., Filippetti, F., & Casadei, D. (2013) · European Conference on Power Electronics and Applications · doi:10.1109/epe.2013.6634730 · Cited by 7 · cited 1×
“In [79], a diagnostic method based on the combination of WT and a pre-processing of rotor voltages in time-varying operations is investigated to identify rotor imbalances.”
MethodSamonig, M. A., & Wolbank, T. M. (2017) · IEEE International Symposium on Diagnostics for Electrical Machines, Power Electronics and Drives (SDEMPED) · doi:10.1109/demped.2017.8062333 · Cited by 7 · cited 1×
“A different technique described in [112] analyzes the transient current response of an IM to an excitation with voltage pulses provided by the inverter switching and proves that the indicator achieved from the transient current response does not depend on the number of slots per pole, while the performance of the MCSA…”
MethodDetection of torque oscillations in induction motor drives by linear discriminant analysis
Frosini, L., Albini, A., & Beccarisi, F. (2017) · IEEE International Symposium on Diagnostics for Electrical Machines, Power Electronics and Drives (SDEMPED) · doi:10.1109/demped.2017.8062403 · Cited by 7 · cited 1×
“In [119], a new approach is described to detect load oscillations by means of the harmonic multiple of the fundamental.”
MethodSelf-citationDiagnosis of stator and rotor faults of an induction motor in closed-loop control structure
Wolkiewicz, M., Tarchała, G., & Orłowska-Kowalska, T. (2018) · International Symposium on Power Electronics, Electrical Drives, Automation and Motion (SPEEDAM) · doi:10.1109/speedam.2018.8445282 · Cited by 6 · cited 2×
“An uncontrolled growth in the damage degree can lead to unstable operation of the drive [16,17].”
BackgroundKia, S. H., Marzebali, M. H., Henao, H., Capolino, G., & Faiz, J. (2017) · IEEE International Symposium on Diagnostics for Electrical Machines, Power Electronics and Drives (SDEMPED) · doi:10.1109/demped.2017.8062367 · Cited by 5 · cited 1×
“In [123], both electrical and mechanical signatures of a WRIM are used for gear fault diagnosis.”
Off-Line Detection of Static Eccentricity in Salient-Pole Synchronous Machines
Gyftakis, K. N., Platero, C. A., & Bernal, S. (2018) · International Conference on Electrical Machines (ICEM) · doi:10.1109/icelmach.2018.8507042 · Cited by 5 · cited 1×
“Regarding salient-pole SMs, in [116], a new off-line technique was proposed to diagnose static eccentricity through the measurement of the three-phase currents in a locked rotor condition, in three rotor positions; the spectrum of a pseudo zero-sequence current provides reliable indicators to identify this fault.”
Stator fault diagnosis by reactive power in dual three-phase reluctance motors
Bianchini, C., Torreggiani, A., Davoli, M., Bellini, A., Babetto, C., & Bianchi, N. (2019) · IEEE International Symposium on Diagnostics for Electrical Machines, Power Electronics and Drives (SDEMPED) · doi:10.1109/demped.2019.8864909 · Cited by 4 · cited 1×
“Another particular machine has been evaluated in [52], i.”
BackgroundCastro-Coronado, H., Daviu, J. A. A., Quijano-López, A., Llovera‐Segovia, P., & Fuster-Roig, V. (2020) · International Conference on Electrical Machines (ICEM) · doi:10.1109/icem49940.2020.9270961 · Cited by 4 · cited 1×
“In [57,58], two further methodologies for identifying damper bar faults in salient pole SMs without disassembly have been proposed.”
MethodStator short-circuit diagnosis in power alternators based on Flux2D/Matlab co-simulation
Filleau, C., Picot, A., Maussion, P., Manfè, P., & Jannot, X. (2017) · IEEE International Symposium on Diagnostics for Electrical Machines, Power Electronics and Drives (SDEMPED) · doi:10.1109/demped.2017.8062359 · Cited by 3 · cited 1×
“The measurement of the phase-to-phase voltage to monitor an SM is instead proposed in [40], together with the collection of the airgap magnetic field through a special coil inserted in the stator slots; the authors demonstrate that the 3rd and 9th harmonics in the voltage and the 3rd component in the magnetic field ar…”
Background
Cited by
Fault Diagnosis and Fault-Tolerant Control of PMSM Drives–State of the Art and Future Challenges
Orlowska-Kowalska, T., Wolkiewicz, M., Pietrzak, P., Skowron, M., Ewert, P., Tarchala, G., Krzysztofiak, M., & Kowalski, C. T. (2022) · IEEE Access · doi:10.1109/access.2022.3180153 · Cited by 328
“The PM demagnetization can be uniform over all poles or partial over certain region or poles [15], [18], [29], [32].”
BackgroundMethodInfluentialEarly Detection of Faults in Induction Motors—A Review
Garcia-Calva, T. A., Moríñigo-Sotelo, D., Fernandez-Cavero, V., & Romero-Troncoso, R. D. J. (2022) · Energies · doi:10.3390/en15217855 · Cited by 124
Magnetic Flux Analysis for the Condition Monitoring of Electric Machines: A Review
Zamudio-Ramírez, I., Osornio-Rios, R. A., Daviu, J. A. A., Razik, H., & Romero-Troncoso, R. D. J. (2021) · IEEE Transactions on Industrial Informatics · doi:10.1109/tii.2021.3070581 · Cited by 130
The Edge Application of Machine Learning Techniques for Fault Diagnosis in Electrical Machines
Morenas, J. D. L., Moya, F., & López-Gómez, J. A. (2023) · Sensors · doi:10.3390/s23052649 · Cited by 88
“The research community is devoting significant efforts to real-time and online solutions [10].”
BackgroundMethodInfluentialThe Bearing Faults Detection Methods for Electrical Machines—The State of the Art
Khan, M. A., Asad, B., Kudelina, K., Vaimann, T., & Kallaste, A. (2022) · Energies · doi:10.3390/en16010296 · Cited by 89
Metadata
- Authors
- Frosini, L.
- Affiliations
- University of Pavia (IT)
- Corresponding author
- Frosini, Lucia
- ORCID
- Frosini, Lucia
- Venue
- Energies
- Publisher
- MDPI AG
- Published
- 2020-09-27
- Volume
- 13
- Issue
- 19
- Pages
- 5066
- ISSN
- 1996-1073 (ISSN-L)
- OpenAlex
- W3088905955
- Cited by
- 67
- References
- 126
- Citations by year
- 2025: 15 · 2024: 9 · 2023: 15 · 2022: 16 · 2021: 12
- FWCI
- 5.32
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Licence
- Locations
- Energies (publishedVersion, cc-by)
- RePEc: Research Papers in Economics (submittedVersion)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
- Topics
- Physical Sciences › Engineering › Control and Systems Engineering › Machine Fault Diagnosis Techniques
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Electric Motor Design and Analysis
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Power Transformer Diagnostics and Insulation
- Keywords
- rotating electrical machines, condition monitoring, fault diagnosis, stator winding, rotor winding, permanent magnets, bearings, air gap, laminated cores, machine diagnostics
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.