Diagnostic Features and Potential Applications of PPG Signal in Healthcare: A Systematic Review
Open accessThe DOI matches its Crossref record; 202 of the 202 references it cites were found in a registry or an index.
Abstract
Recent research indicates that Photoplethysmography (PPG) signals carry more information than oxygen saturation level (SpO2) and can be utilized for affordable, fast, and noninvasive healthcare applications. All these encourage the researchers to estimate its feasibility as an alternative to many expansive, time-wasting, and invasive methods. This systematic review discusses the current literature on diagnostic features of PPG signal and their applications that might present a potential venue to be adapted into many health and fitness aspects of human life. The research methodology is based on the Preferred Reporting Items for Systematic Reviews and Meta-Analysis (PRISMA) guidelines 2020. To this aim, papers from 1981 to date are reviewed and categorized in terms of the healthcare application domain. Along with consolidated research areas, recent topics that are growing in popularity are also discovered. We also highlight the potential impact of using PPG signals on an individual’s quality of life and public health. The state-of-the-art studies suggest that in the years to come PPG wearables will become pervasive in many fields of medical practices, and the main domains include cardiology, respiratory, neurology, and fitness. Main operation challenges, including performance and robustness obstacles, are identified.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
1 retracted
Qawqzeh, Y. K., Bajahzar, A. S., Jemmali, M., Otoom, M. M., & Thaljaoui, A. (2020) · BioMed Research International · doi:10.1155/2020/3764653 · Cited by 71 · cited 1×
“Others use machine learning models, like support vector machine [155] and logistic regression [156], to differentiate between PPG signals for diabetic patients and non-diabetic patients.”
MethodRetractedPage, M. J., Moher, D., Bossuyt, P. M., Boutron, I., Hoffmann, T. C., Mulrow, C. D., Shamseer, L., Tetzlaff, J. M., Akl, E. A., Brennan, S. E., et al. (2021) · BMJ · doi:10.1136/bmj.n160 · Cited by 13,262 · cited 1×
“The PRISMA 2020 guidelines for systematic reviews [19] were followed in order to achieve a valid formulation in this study.”
MethodMIMIC-III, a freely accessible critical care database
Johnson, A. E. W., Pollard, T. J., Shen, L., Lehman, L.-W. H., Feng, M., Ghassemi, M., Moody, B., Szolovits, P., Anthony Celi, L., & Mark, R. G. (2016) · Scientific Data · doi:10.1038/sdata.2016.35 · Cited by 8,141 · cited 1×
“Shortage of data in medical applications: Although there are a couple of medical datasets that contain a PPG signal filed, three of them are drawn from the Medical Information Mart for Intensive Care (MIMIC) database [228] with an alteration.”
Photoplethysmography and its application in clinical physiological measurement
Allen, J. (2007) · Physiological Measurement · doi:10.1088/0967-3334/28/3/r01 · Cited by 3,967 · cited 2×
“This optical waveform, sometimes called digital volume pulse (DVP) [1], is associated with the change in blood volume in the microvascular bed of tissue containing valuable information about the cardiovascular, respiratory, and nervous systems [2].”
BackgroundThe Triad of Sleep Apnea, Hypertension, and Chronic Kidney Disease: A Spectrum of Common Pathology
Aziz, F., & Chaudhary, K. (2017) · Cardiorenal Medicine · doi:10.1159/000450796 · Cited by 3,267
Remote plethysmographic imaging using ambient light
Verkruysse, W., Svaasand, L. O., & Nelson, J. S. (2008) · Optics Express · doi:10.1364/oe.16.021434 · Cited by 1,719
Advancements in Noncontact, Multiparameter Physiological Measurements Using a Webcam
Poh, M.-Z., McDuff, D. J., & Picard, R. W. (2011) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2010.2086456 · Cited by 1,486 · cited 3×
“Pulse rate and its variability • PR [33,34,61,63–65,68] • PRV and CSC [62] • CVD [66] • Vital sign [26,67] • PR [31,60]”
MethodRobust pulse rate from chrominance-based rPPG
de Haan, G., & Jeanne, V. (2013) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2013.2266196 · Cited by 1,378 · cited 1×
“In contact PPG [60–62], pulse rate is measured by placing a finger on the phone rear camera while, in non-contact [33,34,63], iPPG is extracted from the face, without the need for direct skin contact.”
BackgroundOn the Analysis of Fingertip Photoplethysmogram Signals
Elgendi, M. (2012) · Current Cardiology Reviews · doi:10.2174/157340312801215782 · Cited by 1,206
Kaneko, Y., Floras, J. S., Usui, K., Plante, J., Tkacova, R., Kubo, T., Ando, S.-I., & Bradley, T. D. (2003) · New England Journal of Medicine · doi:10.1056/nejmoa022479 · Cited by 1,051 · cited 5×
“PPG was used to monitor obstructive sleep apnea in subjects with HF [138].”
MethodInfluentialGhamari, M. (2018) · International Journal of Biosensors & Bioelectronics · doi:10.15406/ijbsbe.2018.04.00125 · Cited by 945 · cited 2×
“Devices with a PPG sensor could be worn on wrist, nasal [55], ankle, and chest [17].”
BackgroundWearable photoplethysmographic sensors—past and present
Tamura, T., Maeda, Y., Sekine, M., & Yoshida, M. (2014) · Electronics · doi:10.3390/electronics3020282 · Cited by 912 · cited 1×
“Some of them focus on the specific medical use of PPG like pulse rate [3], blood pressure [4,5], atrial fibrillation [6,7], circulatory monitoring [8], nociception [9], or on the specific placement of PPG [10,11], others instead focused on reviewing the way that the signal has been analyzed [7,12–16] or the type of th…”
BackgroundZhang, Z., Pi, Z., & Liu, B. (2015) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2014.2359372 · Cited by 748 · cited 2×
“AFib • 2015 IEEE Signal Processing Cup [226] used in [216] for AFib episodes detection • MIMIC and the University of Queensland Vital Signs Dataset [227] used in [217] for AFib modelingHealthcare 2022, 10, x FOR PEER REVIEW 5 of 28 Figure 3.”
MethodDeepPhys: Video-Based Physiological Measurement Using Convolutional Attention Networks
Chen, W., & McDuff, D. (2018) · Lecture Notes in Computer Science · doi:10.1007/978-3-030-01216-8_22 · Cited by 716
Multifunctional materials for implantable and wearable photonic healthcare devices
Lee, G.-H., Moon, H., Kim, H., Lee, G. H., Kwon, W., Yoo, S., Myung, D., Yun, S. H., Bao, Z., & Hahn, S. K. (2020) · Nature Reviews Materials · doi:10.1038/s41578-019-0167-3 · Cited by 667
The use of photoplethysmography for assessing hypertension
Elgendi, M., Fletcher, R., Liang, Y., Howard, N., Lovell, N. H., Abbott, D., Lim, K., & Ward, R. (2019) · npj Digital Medicine · doi:10.1038/s41746-019-0136-7 · Cited by 625 · cited 3×
“Although current technologies in measuring BP from PPG is not mature, it is anticipated that soon, accurate, continuous BP measurements will be within reach from mobile and wearable devices given their potentials [5].”
BackgroundTakazawa, K., Tanaka, N., Fujita, M., Matsuoka, O., Saiki, T., Aikawa, M., Tamura, S., & Ibukiyama, C. (1998) · Hypertension · doi:10.1161/01.hyp.32.2.365 · Cited by 589 · cited 3×
“Arterial stiffness • Aging [45,57,113–115] • PWV [117] • SI [41,118] • CVD [56,122] • Vascular aging [116] • SI [46,123] • Cardiovascular risk [123] • SI [119,121] • AIX [120]”
BackgroundImproved motion robustness of remote-PPG by using the blood volume pulse signature
de Haan, G., & van Leest, A. (2014) · Physiological Measurement · doi:10.1088/0967-3334/35/9/1913 · Cited by 491
Chung, H. U., Rwei, A. Y., Hourlier-Fargette, A., Xu, S., Lee, K., Dunne, E. C., Xie, Z., Liu, C., Carlini, A., Kim, D. H., et al. (2020) · Nature Medicine · doi:10.1038/s41591-020-0792-9 · Cited by 482 · cited 2×
“[193], designed a small PPG-based, noninvasive, and relatively small adhesive bandage that can be used in NICU or pediatric intensive-care units PICU for vital signs continuous monitoring.”
BackgroundDigital biomarkers for Alzheimer’s disease: the mobile/wearable devices opportunity
Kourtis, L. C., Regele, O. B., Wright, J. M., & Jones, G. B. (2019) · npj Digital Medicine · doi:10.1038/s41746-019-0084-2 · Cited by 476 · cited 5×
“Neuro • Dementia [54,58] • Multiple sclerosis [205] • Pain [206–209]”
BackgroundMethodInfluentialDeep PPG: Large-Scale Heart Rate Estimation with Convolutional Neural Networks
Reiss, A., Indlekofer, I., Schmidt, P., & Van Laerhoven, K. (2019) · Sensors · doi:10.3390/s19143079 · Cited by 377
Charlton, P. H., Bonnici, T., Tarassenko, L., Clifton, D. A., Beale, R., & Watkinson, P. J. (2016) · Physiological Measurement · doi:10.1088/0967-3334/37/4/610 · Cited by 366
Utility of the Photoplethysmogram in Circulatory Monitoring
Reisner, A., Shaltis, P. A., McCombie, D., Asada, H. H., Warner, D. S., & Warner, M. A. (2008) · Anesthesiology · doi:10.1097/aln.0b013e31816c89e1 · Cited by 366 · cited 1×
“Some of them focus on the specific medical use of PPG like pulse rate [3], blood pressure [4,5], atrial fibrillation [6,7], circulatory monitoring [8], nociception [9], or on the specific placement of PPG [10,11], others instead focused on reviewing the way that the signal has been analyzed [7,12–16] or the type of th…”
BackgroundPhotoplethysmographic assessment of pulse wave reflection
Chowienczyk, P. J., Kelly, R. P., MacCallum, H., Millasseau, S. C., Andersson, T. L. G., Gosling, R. G., Ritter, J. M., & Änggård, E. E. (1999) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(99)00441-6 · Cited by 363
Vital-sign monitoring and spatial tracking of multiple people using a contactless radar-based sensor
Mercuri, M., Lorato, I. R., Liu, Y.-H., Wieringa, F., Hoof, C. V., & Torfs, T. (2019) · Nature Electronics · doi:10.1038/s41928-019-0258-6 · Cited by 354 · cited 2×
“This was similarly true for iPPG from long-distance [66], and among the crowd [67].”
BackgroundHeart rate measurement based on a time-lapse image.
Takano, C., & Ohta, Y. (2007) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2006.09.006 · Cited by 345 · cited 1×
“PR was successfully extracted from the face using affordable cameras, and high degrees of agreement with the standard tools were achieved [26,65].”
MethodAutomated Detection of Engagement Using Video-Based Estimation of Facial Expressions and Heart Rate
Monkaresi, H., Bosch, N., Calvo, R. A., & D'Mello, S. K. (2017) · IEEE Transactions on Affective Computing · doi:10.1109/taffc.2016.2515084 · Cited by 329
Remote measurement of cognitive stress via heart rate variability
McDuff, D., Gontarek, S., & Picard, R. (2014) · 2014 36th Annual International Conference of the IEEE Engineering in Medicine and Biology Society · doi:10.1109/embc.2014.6944243 · Cited by 308
Photoplethysmography based atrial fibrillation detection: a review
Pereira, T., Tran, N., Gadhoumi, K., Pelter, M. M., Do, D. H., Lee, R. J., Colorado, R., Meisel, K., & Hu, X. (2020) · npj Digital Medicine · doi:10.1038/s41746-019-0207-9 · Cited by 300 · cited 1×
“Some of them focus on the specific medical use of PPG like pulse rate [3], blood pressure [4,5], atrial fibrillation [6,7], circulatory monitoring [8], nociception [9], or on the specific placement of PPG [10,11], others instead focused on reviewing the way that the signal has been analyzed [7,12–16] or the type of th…”
BackgroundSeshadri, D. R., Davies, E. V., Harlow, E. R., Hsu, J. J., Knighton, S. C., Walker, T. A., Voos, J. E., & Drummond, C. K. (2020) · Frontiers in Digital Health · doi:10.3389/fdgth.2020.00008 · Cited by 298 · cited 2×
“Additionally, the interesting idea is to estimate the quarantine duration for each individual using wearable devices [199].”
BackgroundAdvances in Photopletysmography Signal Analysis for Biomedical Applications
Moraes, J. L., Rocha, M. X., Vasconcelos, G. G., Vasconcelos Filho, J. E., De Albuquerque, V. H. C., & Alexandria, A. R. (2018) · Sensors · doi:10.3390/s18061894 · Cited by 292
Alian, A. A., & Shelley, K. H. (2014) · Best Practice & Research Clinical Anaesthesiology · doi:10.1016/j.bpa.2014.08.006 · Cited by 289 · cited 2×
“Abstract representation: Clinical oximeter should be able to show more detailed information about the PPG signal to the practicing clinicians [213].”
BackgroundImprovements in Remote Cardiopulmonary Measurement Using a Five Band Digital Camera
McDuff, D., Gontarek, S., & Picard, R. W. (2014) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2014.2323695 · Cited by 287 · cited 1×
“iPPG can predict PRV remotely under cognitive stress [173–175] and under mental arithmetic test [176,177].”
A new look at the essence of the imaging photoplethysmography
Kamshilin, A. A., Nippolainen, E., Sidorov, I. S., Vasilev, P. V., Erofeev, N. P., Podolian, N. P., & Romashko, R. V. (2015) · Scientific Reports · doi:10.1038/srep10494 · Cited by 248 · cited 1×
“The light strength collected by the photodetector is affected by multiple factors, such as the blood volume, blood vessel wall movement, and the orientation of red blood cells [36].”
BackgroundSmartphone-Based Blood Pressure Measurement Using Transdermal Optical Imaging Technology
Luo, H., Yang, D., Barszczyk, A., Vempala, N., Wei, J., Wu, S. J., Zheng, P. P., Fu, G., Lee, K., & Feng, Z.-P. (2019) · Circulation: Cardiovascular Imaging · doi:10.1161/circimaging.119.008857 · Cited by 241 · cited 1×
“A couple of studies [97,100–102] monitor the BP iPPG from a camera; others used smartphone cameras [84,101].”
BackgroundPP-Net: A Deep Learning Framework for PPG-Based Blood Pressure and Heart Rate Estimation
Panwar, M., Gautam, A., Biswas, D., & Acharyya, A. (2020) · IEEE Sensors Journal · doi:10.1109/jsen.2020.2990864 · Cited by 237 · cited 2×
“Some researchers use machine learning algorithms [106], such as deep convolutional autoencoder (DCAE) [87], Nearest Neighbor (NN), Support Vector Machines (SVM), Decision Trees (DT), Neural Networks [88,89,102,107,108], etc.”
BackgroundHumphreys, K., Ward, T., & Markham, C. (2007) · Review of Scientific Instruments · doi:10.1063/1.2724789 · Cited by 217 · cited 12×
“Measuring patient SpO2 using a finger is a standard practice in inpatient monitoring or outpatient checkup.”
InfluentialPhotoelectric Plethysmography of the Fingers and Toes in Man
Hertzman, A. B. (1937) · Experimental Biology and Medicine · doi:10.3181/00379727-37-9630 · Cited by 210 · cited 1×
“Photoelectric plethysmography can be captured from fingers, toes, and nasal septum [20].”
BackgroundReal-world heart rate norms in the Health eHeart study
Avram, R., Tison, G. H., Aschbacher, K., Kuhar, P., Vittinghoff, E., Butzner, M., Runge, R., Wu, N., Pletcher, M. J., Marcus, G. M., et al. (2019) · npj Digital Medicine · doi:10.1038/s41746-019-0134-9 · Cited by 207 · cited 1×
“Pulse rate and its variability • PR [33,34,61,63–65,68] • PRV and CSC [62] • CVD [66] • Vital sign [26,67] • PR [31,60]”
Ding, X., Yan, B. P., Zhang, Y.-T., Liu, J., Zhao, N., & Tsang, H. K. (2017) · Scientific Reports · doi:10.1038/s41598-017-11507-3 · Cited by 197 · cited 1×
“A couple of studies [97,100–102] monitor the BP iPPG from a camera; others used smartphone cameras [84,101].”
BackgroundDing, X.-R., Zhao, N., Yang, G.-Z., Pettigrew, R. I., Lo, B., Miao, F., Li, Y., Liu, J., & Zhang, Y.-T. (2016) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2016.2620995 · Cited by 181 · cited 1×
“The relationship between PWV and PTT; that is, PWV = L/PTT, where L is the distance between the heart and some peripheral sites [39].”
BackgroundAge-related changes in peripheral pulse timing characteristics at the ears, fingers and toes
Allen, J., & Murray, A. (2002) · Journal of Human Hypertension · doi:10.1038/sj.jhh.1001478 · Cited by 179
Assessment of Non-Invasive Blood Pressure Prediction from PPG and rPPG Signals Using Deep Learning
Schrumpf, F., Frenzel, P., Aust, C., Osterhoff, G., & Fuchs, M. (2021) · Sensors · doi:10.3390/s21186022 · Cited by 173 · cited 2×
“Some researchers use machine learning algorithms [106], such as deep convolutional autoencoder (DCAE) [87], Nearest Neighbor (NN), Support Vector Machines (SVM), Decision Trees (DT), Neural Networks [88,89,102,107,108], etc.”
BackgroundPark, C. Y., Cha, N., Kang, S., Kim, A., Khandoker, A. H., Hadjileontiadis, L., Oh, A., Jeong, Y., & Lee, U. (2020) · Scientific Data · doi:10.1038/s41597-020-00630-y · Cited by 169 · cited 2×
“Psychiatry • K-EmoCon used in [168] for continuous emotion recognition”
MethodDeep learning enables sleep staging from photoplethysmogram for patients with suspected sleep apnea
Korkalainen, H., Aakko, J., Duce, B., Kainulainen, S., Leino, A., Nikkonen, S., Afara, I. O., Myllymaa, S., Töyräs, J., & Leppänen, T. (2020) · SLEEP · doi:10.1093/sleep/zsaa098 · Cited by 169 · cited 4×
“Sleep Disorders • BP and PR [138] • BP [42] • CVD [42,146] • Sleep staging [132] • Apnea [133,138,147]”
BackgroundMethodInfluentialInternational Affective Picture System
Bradley, M. M., & Lang, P. J. (2017) · Springer eBooks · doi:10.1007/978-3-319-28099-8_42-1 · Cited by 164
Speer, K. E., Semple, S., Naumovski, N., & McKune, A. J. (2020) · European Journal of Investigation in Health Psychology and Education · doi:10.3390/ejihpe10010029 · Cited by 160 · cited 7×
“A PPG earlobe sensor was used to monitor PRV induced by mental stress [170].”
MethodInfluentialRemote Detection of Photoplethysmographic Systolic and Diastolic Peaks Using a Digital Camera
McDuff, D., Gontarek, S., & Picard, R. W. (2014) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2014.2340991 · Cited by 154 · cited 1×
“iPPG can predict PRV remotely under cognitive stress [173–175] and under mental arithmetic test [176,177].”
Liu, D., Görges, M., & Jenkins, S. A. (2012) · Anesthesia & Analgesia · doi:10.1213/ane.0b013e318241f7c0 · Cited by 151 · cited 2×
“AFib • 2015 IEEE Signal Processing Cup [226] used in [216] for AFib episodes detection • MIMIC and the University of Queensland Vital Signs Dataset [227] used in [217] for AFib modelingHealthcare 2022, 10, x FOR PEER REVIEW 5 of 28 Figure 3.”
MethodNon-contact physiological monitoring of preterm infants in the Neonatal Intensive Care Unit
Villarroel, M., Chaichulee, S., Jorge, J., Davis, S., Green, G., Arteta, C., Zisserman, A., McCormick, K., Watkinson, P., & Tarassenko, L. (2019) · npj Digital Medicine · doi:10.1038/s41746-019-0199-5 · Cited by 149
Can Photoplethysmography Replace Arterial Blood Pressure in the Assessment of Blood Pressure?
Martínez, G., Howard, N., Abbott, D., Lim, K. I., Ward, R. K., & Elgendi, M. (2018) · Journal of Clinical Medicine · doi:10.3390/jcm7100316 · Cited by 149
Wu, T., Blažek, V., & Schmitt, H. J. (2000) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.407646 · Cited by 143
Shin, H., & Min, S. D. (2017) · BioMedical Engineering OnLine · doi:10.1186/s12938-016-0302-y · Cited by 142
Deep Learning Methods for Remote Heart Rate Measurement: A Review and Future Research Agenda
Cheng, C.-H., Wong, K. L., Chin, J. W., Chan, T. T., & So, R. H. Y. (2021) · Sensors · doi:10.3390/s21186296 · Cited by 139 · cited 1×
“Deep learning hype is also brought to the field of iPPG [14,15].”
BackgroundCharlton, P. H., Bonnici, T., Tarassenko, L., Alastruey, J., Clifton, D. A., Beale, R., & Watkinson, P. J. (2017) · Physiological Measurement · doi:10.1088/1361-6579/aa670e · Cited by 138 · cited 2×
“Extracted RR from finger PPG has better quality than extracted from ear PPG [110].”
MethodCuffless Single-Site Photoplethysmography for Blood Pressure Monitoring
Hosanee, M., Chan, G., Welykholowa, K., Cooper, R., Kyriacou, P. A., Zheng, D., Allen, J., Abbott, D., Menon, C., Lovell, N. H., et al. (2020) · Journal of Clinical Medicine · doi:10.3390/jcm9030723 · Cited by 136 · cited 1×
“Some of them focus on the specific medical use of PPG like pulse rate [3], blood pressure [4,5], atrial fibrillation [6,7], circulatory monitoring [8], nociception [9], or on the specific placement of PPG [10,11], others instead focused on reviewing the way that the signal has been analyzed [7,12–16] or the type of th…”
BackgroundMulti-task deep learning for cardiac rhythm detection in wearable devices
Torres-Soto, J., & Ashley, E. A. (2020) · npj Digital Medicine · doi:10.1038/s41746-020-00320-4 · Cited by 136
von Wowern, E., Östling, G., Nilsson, P. M., & Olofsson, P. (2015) · PLOS ONE · doi:10.1371/journal.pone.0135659 · Cited by 134
PPG2ABP: Translating photoplethysmogram (PPG) signals to arterial blood pressure (ABP) waveforms
Ibtehaz, N., Mahmud, S., Chowdhury, M. E. H., Khandakar, A., Salman Khan, M., Ayari, M. A., Tahir, A. M., & Rahman, M. S. (2022) · Bioengineering · doi:10.3390/bioengineering9110692 · Cited by 133 · cited 2×
“Some researchers use machine learning algorithms [106], such as deep convolutional autoencoder (DCAE) [87], Nearest Neighbor (NN), Support Vector Machines (SVM), Decision Trees (DT), Neural Networks [88,89,102,107,108], etc.”
BackgroundA digital biomarker of diabetes from smartphone-based vascular signals
Avram, R., Olgin, J. E., Kuhar, P., Hughes, J. W., Marcus, G. M., Pletcher, M. J., Aschbacher, K., & Tison, G. H. (2020) · Nature Medicine · doi:10.1038/s41591-020-1010-5 · Cited by 133 · cited 1×
“DNN is used to build a biomarker of diabetes from PPG signals collected using a smartphone app from 53,870 participants [159].”
MethodAssessing mental stress from the photoplethysmogram: a numerical study
Charlton, P. H., Celka, P., Farukh, B., Chowienczyk, P., & Alastruey, J. (2018) · Physiological Measurement · doi:10.1088/1361-6579/aabe6a · Cited by 131 · cited 1×
“[169] identify features of PPG that can indicate mental stress.”
BackgroundMartin, S. L.-O., Carek, A. M., Kim, C.-S., Ashouri, H., Inan, O. T., Hahn, J.-O., & Mukkamala, R. (2016) · Scientific Reports · doi:10.1038/srep39273 · Cited by 130 · cited 4×
“It is noticeable that PTT is commonly used to estimate blood pressure [40], and PWV”
BackgroundMethodInfluentialAccuracy of smartphone apps for heart rate measurement
Coppetti, T., Brauchlin, A., Müggler, S., Attinger-Toller, A., Templin, C., Schönrath, F., Hellermann, J., Lüscher, T. F., Biaggi, P., & Wyss, C. A. (2017) · European Journal of Preventive Cardiology · doi:10.1177/2047487317702044 · Cited by 128 · cited 1×
“In general, contact PPG-based apps showed better accuracy than non-contact PPG-based apps [64].”
BackgroundA New Wearable Device for Blood Pressure Estimation Using Photoplethysmogram
Lazazzera, R., Belhaj, Y., & Carrault, G. (2019) · Sensors · doi:10.3390/s19112557 · Cited by 121
Atrial fibrillation detection from wrist photoplethysmography signals using smartwatches
Bashar, S. K., Han, D., Hajeb-Mohammadalipour, S., Ding, E., Whitcomb, C., McManus, D. D., & Chon, K. H. (2019) · Scientific Reports · doi:10.1038/s41598-019-49092-2 · Cited by 120 · cited 1×
“Detecting AFib using wearable devices is a feasible and reliable approach during inpatient physical activity [214] or free-living conditions [180,215,216].”
A Review of Deep Learning-Based Contactless Heart Rate Measurement Methods
Ni, A., Azarang, A., & Kehtarnavaz, N. (2021) · Sensors · doi:10.3390/s21113719 · Cited by 119 · cited 1×
“Deep learning hype is also brought to the field of iPPG [14,15].”
BackgroundCuffless blood pressure estimation using only a smartphone
Matsumura, K., Rolfe, P. J., Toda, S., & Yamakoshi, T. (2018) · Scientific Reports · doi:10.1038/s41598-018-25681-5 · Cited by 116
CapnoBase: Signal database and tools to collect, share and annotate respiratory signals
Karlen, W., Turner, M., Cooke, E., Dumont, G. A., & Ansermino, J. M. (2010) · Repository for Publications and Research Data (ETH Zurich) · doi:10.3929/ethz-b-000087887 · Cited by 114
Nachman, D., Gepner, Y., Goldstein, N., Kabakov, E., Ishay, A. B., Littman, R., Azmon, Y., Jaffe, E., & Eisenkraft, A. (2020) · Scientific Reports · doi:10.1038/s41598-020-73172-3 · Cited by 113
Pulse Oximetry: Uses and Limitations
DeMeulenaere, S. (2007) · The Journal for Nurse Practitioners · doi:10.1016/j.nurpra.2007.02.021 · Cited by 112 · cited 3×
“Pulse oximeter reading for normal resting heart for adults ranges from about 60 to 100 beats per minute, although some cases might be lower like athletes [22].”
BackgroundXing, X., Ma, Z., Zhang, M., Zhou, Y., Dong, W., & Song, M. (2019) · Scientific Reports · doi:10.1038/s41598-019-45175-2 · Cited by 109
In-Ear SpO2: A Tool for Wearable, Unobtrusive Monitoring of Core Blood Oxygen Saturation
Davies, H. J., Williams, I., Peters, N. S., & Mandic, D. P. (2020) · Sensors · doi:10.3390/s20174879 · Cited by 106 · cited 12×
“Measuring patient SpO2 using a finger is a standard practice in inpatient monitoring or outpatient checkup.”
BackgroundInfluentialDetection and Classification of Sleep Apnea and Hypopnea Using PPG and SpO$_2$ Signals
Lazazzera, R., Deviaene, M., Varon, C., Buyse, B., Testelmans, D., Laguna, P., Gil, E., & Carrault, G. (2020) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2020.3028041 · Cited by 105
Photoplethysmography and nociception
KORHONEN, I., & YLI‐HANKALA, A. (2009) · Acta Anaesthesiologica Scandinavica · doi:10.1111/j.1399-6576.2009.02026.x · Cited by 104
Physiological Sensors Based Emotion Recognition While Experiencing Tactile Enhanced Multimedia
Raheel, A., Majid, M., Alnowami, M. R., & Anwar, S. M. (2020) · Sensors · doi:10.3390/s20144037 · Cited by 100 · cited 2×
“• Anxiety [162,165,167] • Vascular tone [165] • Emotions [162,164,167].”
BackgroundRong, M., & Li, K. (2020) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2020.102328 · Cited by 100 · cited 1×
“Some researchers use machine learning algorithms [106], such as deep convolutional autoencoder (DCAE) [87], Nearest Neighbor (NN), Support Vector Machines (SVM), Decision Trees (DT), Neural Networks [88,89,102,107,108], etc.”
BackgroundA Noninvasive Glucose Monitoring SoC Based on Single Wavelength Photoplethysmography
Hina, A., & Saadeh, W. (2020) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2020.2979514 · Cited by 99 · cited 2×
“With the aid of machine learning techniques, PPG shows advances in measuring glucose levels [157,158].”
MethodZheng, Y., Poon, C. C. Y., Yan, B. P., & Lau, J. Y. W. (2016) · Journal of Medical Systems · doi:10.1007/s10916-016-0558-6 · Cited by 94 · cited 1×
“Blood pressure • Hypertension [5,99] • Orthostatic hypotension [93,94,96] • CVD [104,105] • CVD [91] • BP [40,43,80–100,102,106–108] -”
Papini, G. B., Fonseca, P., van Gilst, M. M., Bergmans, J. W. M., Vullings, R., & Overeem, S. (2020) · Scientific Reports · doi:10.1038/s41598-020-69935-7 · Cited by 90 · cited 21×
“Cardiovascular Diseases (CVDs) According to World Health Organization (WHO), cardiovascular diseases (CVDs), are the leading cause of death globally.”
MethodInfluentialPrediction of Amputation Wound Healing
Barnes, R. W. (1981) · Archives of Surgery · doi:10.1001/archsurg.1981.01380130056013 · Cited by 90
TERAI, M., OHISHI, M., ITO, N., TAKAGI, T., TATARA, Y., KAIBE, M., KOMAI, N., RAKUGI, H., & OGIHARA, T. (2008) · Hypertension Research · doi:10.1291/hypres.31.1135 · Cited by 89
Pervasive blood pressure monitoring using Photoplethysmogram (PPG) sensor
Riaz, F., Azad, M. A., Arshad, J., Imran, M. A., Hassan, A., & Rehman, S. (2019) · Future Generation Computer Systems · doi:10.1016/j.future.2019.02.032 · Cited by 85 · cited 2×
“Some researchers use machine learning algorithms [106], such as deep convolutional autoencoder (DCAE) [87], Nearest Neighbor (NN), Support Vector Machines (SVM), Decision Trees (DT), Neural Networks [88,89,102,107,108], etc.”
BackgroundМихайлович, У. А. (2018) · Biomedical Physics & Engineering Express · doi:10.1088/2057-1976/aabd09 · Cited by 82 · cited 2×
“Pulse rate and its variability • PR [33,34,61,63–65,68] • PRV and CSC [62] • CVD [66] • Vital sign [26,67] • PR [31,60]”
MethodArterial stiffness indices in healthy volunteers using non‐invasive digital photoplethysmography
Brillante, D., O’Sullivan, A., & Howes, L. G. (2008) · Blood Pressure · doi:10.1080/08037050802059225 · Cited by 81 · cited 10×
“[117] consider PPG alone as a handy method of measuring arterial stiffness.”
MethodInfluentialDjeldjli, D., Bousefsaf, F., Maaoui, C., Bereksi-Reguig, F., & Pruski, A. (2020) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2020.102242 · Cited by 80 · cited 1×
“Arterial stiffness [41,113–115,117–121,123] [35,126] [45,46,56,57,116]”
Assessment of cardiovascular function from multi-Gaussian fitting of a finger photoplethysmogram
Couceiro, R., Carvalho, P., Paiva, R. P., Henriques, J. M. O., Quintal, I., Antunes, M., Muehlsteff, J., Eickholt, C., Brinkmeyer, C., Kelm, M., et al. (2015) · Physiological Measurement · doi:10.1088/0967-3334/36/9/1801 · Cited by 79 · cited 2×
“Blood pressure • Hypertension [5,99] • Orthostatic hypotension [93,94,96] • CVD [104,105] • CVD [91] • BP [40,43,80–100,102,106–108] -”
BackgroundNon-contact hemodynamic imaging reveals the jugular venous pulse waveform
Amelard, R., Hughson, R. L., Greaves, D. K., Pfisterer, K. J., Leung, J., Clausi, D. A., & Wong, A. M. (2017) · Scientific Reports · doi:10.1038/srep40150 · Cited by 78
An Evaluation of Biometric Monitoring Technologies for Vital Signs in the Era of COVID‐19
Manta, C. J., Jain, S. S., Coravos, A., Mendelsohn, D., & Izmailova, E. S. (2020) · Clinical and Translational Science · doi:10.1111/cts.12874 · Cited by 72 · cited 1×
“PPG wearables can measure a patient’s PR, BP, SpO2, and respiratory rate [75,199,200].”
BackgroundEbrahim, M. P., Heydari, F., Wu, T., Walker, K., Joe, K., Redouté, J., & Yuce, M. R. (2019) · Scientific Reports · doi:10.1038/s41598-019-52710-8 · Cited by 71
Modeling of the photoplethysmogram during atrial fibrillation
Sološenko, A., Petrėnas, A., Marozas, V., & Sörnmo, L. (2017) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2016.12.016 · Cited by 69 · cited 2×
“AFib • 2015 IEEE Signal Processing Cup [226] used in [216] for AFib episodes detection • MIMIC and the University of Queensland Vital Signs Dataset [227] used in [217] for AFib modeling Healthcare 2022, 10, x FOR PEER REVIEW 5 of 28”
MethodShilaih, M., Clerck, V. D., Falco, L., Kübler, F., & Leeners, B. (2017) · Scientific Reports · doi:10.1038/s41598-017-01433-9 · Cited by 69 · cited 2×
“There are other medical applications of PPG waveform that have not gained much attention, like fertility monitoring [220], end-organ damage [53], wound healing prediction [221], and hematologic disorder [222].”
BackgroundNirala, N., Periyasamy, R., Singh, B. K., & Kumar, A. (2018) · Journal of Applied Biomedicine · doi:10.1016/j.bbe.2018.09.007 · Cited by 68 · cited 1×
“Others use machine learning models, like support vector machine [155] and logistic regression [156], to differentiate between PPG signals for diabetic patients and non-diabetic patients.”
MethodDehkordi, P., Garde, A., Molavi, B., Ansermino, J. M., & Dumont, G. A. (2018) · Frontiers in Physiology · doi:10.3389/fphys.2018.00948 · Cited by 66 · cited 2×
“Respiration rate [70,71,110] [68,112] [111]”
MethodIdentification of Atrial Fibrillation by Quantitative Analyses of Fingertip Photoplethysmogram
Tang, S.-C., Huang, P.-W., Hung, C.-S., Shan, S.-M., Lin, Y.-H., Shieh, J.-S., Lai, D.-M., Wu, A.-Y., & Jeng, J.-S. (2017) · Scientific Reports · doi:10.1038/srep45644 · Cited by 66 · cited 6×
“PPG is also used to monitor patients in the intensive care unit (ICU) and the Neonatal Intensive Care Unit (NICU) [134,178,179].”
BackgroundMethodInfluentialFung, K., Ramírez, J., Warren, H. R., Aung, N., Lee, A. M., Tzanis, E., Petersen, S. E., & Munroe, P. B. (2019) · Scientific Reports · doi:10.1038/s41598-019-45703-0 · Cited by 65 · cited 2×
“Arterial stiffness • Aging [45,57,113–115] • PWV [117] • SI [41,118] • CVD [56,122] • Vascular aging [116] • SI [46,123] • Cardiovascular risk [123] • SI [119,121] • AIX [120]”
BackgroundZahedi, E., Chellappan, K., Ali, M. A. M., & Singh, H. (2007) · Cardiovascular Engineering An International Journal · doi:10.1007/s10558-007-9037-5 · Cited by 64
Extracting the Jugular Venous Pulse from Anterior Neck Contact Photoplethysmography
García-López, I., & Rodriguez–Villegas, E. (2020) · Scientific Reports · doi:10.1038/s41598-020-60317-7 · Cited by 64 · cited 1×
“Several studies investigate noninvasive JVP measurement, using a contact PPG sensor placed on the neck [69] or a regular video camera [124–126].”
BackgroundPu, L. J., Shen, Y., Lu, L., Zhang, R., Zhang, Q., & Shen, W. F. (2012) · Cardiovascular Diabetology · doi:10.1186/1475-2840-11-110 · Cited by 63 · cited 1×
“A study in 2012 [148] reported a false reading of pulse oximeter when”
BackgroundPhotoplethysmographic signal waveform index for detection of increased arterial stiffness
Pilt, K., Meigas, K., Ferenets, R., Temitski, K., & Viigimaa, M. (2014) · Physiological Measurement · doi:10.1088/0967-3334/35/10/2027 · Cited by 62 · cited 1×
“Arterial stiffness • Aging [45,57,113–115] • PWV [117] • SI [41,118] • CVD [56,122] • Vascular aging [116] • SI [46,123] • Cardiovascular risk [123] • SI [119,121] • AIX [120]”
Detection of Respiratory Arousals Using Photoplethysmography (PPG) Signal in Sleep Apnea Patients
Karmakar, C. K., Khandoker, A. H., Penzel, T., Schöbel, C., & Palaniswami, M. S. (2013) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2013.2282338 · Cited by 62 · cited 2×
“Sleep Disorders • BP and PR [138] • BP [42] • CVD [42,146] • Sleep staging [132] • Apnea [133,138,147]”
BackgroundEerikäinen, L. M., Bonomi, A. G., Schipper, F., Dekker, L. R. C., Vullings, R., de Morree, H. M., & Aarts, R. M. (2018) · Physiological Measurement · doi:10.1088/1361-6579/aad2c0 · Cited by 61 · cited 3×
“Monitoring OPD • CVDs [180,181] • Peripheral neuropathy [149] • Dementia [54,58]”
BackgroundChitnis, T., Glanz, B. I., Gonzalez, C. T., Healy, B. C., Saraceno, T. J., Sattarnezhad, N., Diaz‐Cruz, C., Polgar‐Turcsanyi, M., Tummala, S., Bakshi, R., et al. (2019) · npj Digital Medicine · doi:10.1038/s41746-019-0197-7 · Cited by 61
Lin, W.-H., Chen, F., Geng, Y., Ji, N., Fang, P., & Li, G. (2020) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2020.102198 · Cited by 61
Yousefian, P., Shin, S., Mousavi, A. S., Kim, C., Mukkamala, R., Jang, D.-G., Ko, B.-H., Lee, J., Kwon, U.-K., Kim, Y. H., et al. (2019) · Scientific Reports · doi:10.1038/s41598-019-46936-9 · Cited by 59 · cited 2×
“Many researchers evaluate the estimation of BP using PPG signal only [43,80–89], while others paired it with other types of signals, such as ECG [43,90,91] and BCG [40,92].”
BackgroundMethodComparison of photoplethysmographic and arterial tonometry-derived indices of arterial stiffness
Clarenbach, C. F., Stoewhas, A., van Gestel, A. J. R., Latshang, T. D., Cascio, C. M. L., Bloch, K. E., & Kohler, M. (2011) · Hypertension Research · doi:10.1038/hr.2011.168 · Cited by 55 · cited 3×
“Arterial stiffness • Aging [45,57,113–115] • PWV [117] • SI [41,118] • CVD [56,122] • Vascular aging [116] • SI [46,123] • Cardiovascular risk [123] • SI [119,121] • AIX [120]”
BackgroundSadrawi, M., Lin, Y.-T., Lin, C., Mathunjwa, B. M., Fan, S., Abbod, M., & Shieh, J.-S. (2020) · Sensors · doi:10.3390/s20143829 · Cited by 53 · cited 2×
“Some researchers use machine learning algorithms [106], such as deep convolutional autoencoder (DCAE) [87], Nearest Neighbor (NN), Support Vector Machines (SVM), Decision Trees (DT), Neural Networks [88,89,102,107,108], etc.”
BackgroundOtsuka, T., Kawada, T., Katsumata, M., Ibuki, C., & Kusama, Y. (2007) · Hypertension Research · doi:10.1291/hypres.30.1211 · Cited by 53 · cited 1×
“Several studies [45,47,49] show that SDPTG is significantly associated with CVD.”
BackgroundAmelard, R., Scharfenberger, C., Kazemzadeh, F., Pfisterer, K. J., Lin, B. S., Clausi, D. A., & Wong, A. K. C. (2015) · Scientific Reports · doi:10.1038/srep14637 · Cited by 53 · cited 20×
“Cardiovascular Diseases (CVDs) According to World Health Organization (WHO), cardiovascular diseases (CVDs), are the leading cause of death globally.”
BackgroundInfluentialFernández‐Aguilar, L., Latorre, J. M., Martínez‐Rodrigo, A., Moncho-Bogani, J., Ros, L., Latorre, P., Ricarte, J. J., & Fernández‐Caballero, A. (2020) · Scientific Reports · doi:10.1038/s41598-020-71430-y · Cited by 52 · cited 2×
“• Physiological response [29,163,166] • Age [163] • stress [27,169–171] • Cognitive load [172,174–177]”
BackgroundDetection of Drivers’ Anxiety Invoked by Driving Situations Using Multimodal Biosignals
Lee, S., Lee, T., Yang, T., Yoon, C., & Kim, S.-P. (2020) · Processes · doi:10.3390/pr8020155 · Cited by 52
Buchs, A. E., Slovik, Y., Rapoport, M. J., Rosenfeld, C., Khanokh, B., & Nitzan, M. (2005) · Medical & Biological Engineering & Computing · doi:10.1007/bf02345963 · Cited by 51
Remote detection of mental workload changes using cardiac parameters assessed with a low-cost webcam
Bousefsaf, F., Maaoui, C., & Pruski, A. (2014) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2014.07.014 · Cited by 50
Wojcikowski, M., & Pankiewicz, B. (2020) · Sensors · doi:10.3390/s20061783 · Cited by 49 · cited 1×
“CVDs • CapnoBase [223] used in [136] • PPG-DaLia [224] used in [72]”
MethodPhotoplethysmography: Analysis of the Pulse Oximeter Waveform
Alian, A. A., & Shelley, K. H. (2013) · Springer eBooks · doi:10.1007/978-1-4614-8557-5_19 · Cited by 48
Prediction of state anxiety by machine learning applied to photoplethysmography data
Perpetuini, D., Chiarelli, A. M., Cardone, D., Filippini, C., Rinella, S., Massimino, S., Bianco, F., Bucciarelli, V., Vinciguerra, V., Fallica, P. G., et al. (2021) · PeerJ · doi:10.7717/peerj.10448 · Cited by 47 · cited 2×
“• Anxiety [162,165,167] • Vascular tone [165] • Emotions [162,164,167].”
BackgroundRodrigues, L. M., Rocha, C., Ferreira, H. A., & Silva, H. (2019) · Scientific Reports · doi:10.1038/s41598-019-53213-2 · Cited by 47 · cited 2×
“Microcirculatory • Perfusion change [28,32,130] -”
MethodSun, Z., He, Q., Li, Y., Wang, W., & Wang, R. K. (2021) · Biomedical Optics Express · doi:10.1364/boe.419268 · Cited by 46
Varma, N., Marrouche, N. F., Aguinaga, L., Albert, C. M., Arbelo, E., Choi, J.-I., Chung, M. K., Conte, G., Dagher, L., Epstein, L. M., et al. (2020) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2020.06.019 · Cited by 44
Impact of slow breathing on the blood pressure and subarachnoid space width oscillations in humans
Nuckowska, M. K., Gruszecki, M., Kot, J., Wolf, J., Gumiński, W., Frydrychowski, A. F., Wtorek, J., Narkiewicz, K., & Winklewski, P. J. (2019) · Scientific Reports · doi:10.1038/s41598-019-42552-9 · Cited by 44 · cited 1×
“[95] studied slow breathing on BP measured by PPG.”
MethodInoue, N., Kawakami, H., Yamamoto, H., Ito, C., Fujiwara, S., Sasaki, H., & Kihara, Y. (2016) · Hypertension Research · doi:10.1038/hr.2016.123 · Cited by 44 · cited 1×
“Several studies [45,47,49] show that SDPTG is significantly associated with CVD.”
BackgroundEEG-Brain Activity Monitoring and Predictive Analysis of Signals Using Artificial Neural Networks
Aileni, R. M., Pasca, S., & Florescu, A. (2020) · Sensors · doi:10.3390/s20123346 · Cited by 44
Ishbulatov, Y. M., Karavaev, A. S., Kiselev, A. R., Simonyan, M. A., Prokhorov, M. D., Пономаренко, В. И., Mironov, S. A., Gridnev, V. I., Bezruchko, B. P., & Shvartz, V. A. (2020) · Scientific Reports · doi:10.1038/s41598-020-71532-7 · Cited by 43 · cited 20×
“Cardiovascular Diseases (CVDs) According to World Health Organization (WHO), cardiovascular diseases (CVDs), are the leading cause of death globally.”
BackgroundInfluentialChiarelli, A. M., Bianco, F., Perpetuini, D., Bucciarelli, V., Filippini, C., Cardone, D., Zappasodi, F., Gallina, S., & Merla, A. (2019) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2019.07.009 · Cited by 43 · cited 3×
“Arterial stiffness [41,113–115,117–121,123] [35,126] [45,46,56,57,116]”
BackgroundPhotoplethysmogram second derivative review: Analysis and applications
Yousef, K. Q., Rubīns, U., & Alharbi, M. (2015) · Scientific Research and Essays · doi:10.5897/sre2015.6322 · Cited by 43 · cited 3×
“[44] introduced the first and second derivatives of the PPG (SDPTG) [16] as a method to recognize the inflection points of the PPG Figure 5.”
MethodInfluentialLiu, Z.-D., Zhou, B., Li, Y., Tang, M., & Miao, F. (2020) · Frontiers in Physiology · doi:10.3389/fphys.2020.575407 · Cited by 42 · cited 10×
“The study simultaneously recorded ECG and PPG signals in patients admitted to the ICU with a stroke.”
InfluentialMachine learning detection of obstructive hypertrophic cardiomyopathy using a wearable biosensor
Green, E. M., van Mourik, R. A., Wolfus, C., Heitner, S. B., Dur, O., & Semigran, M. J. (2019) · npj Digital Medicine · doi:10.1038/s41746-019-0130-0 · Cited by 42 · cited 2×
“Diagnosis CVDs • Cardiac output [136,142] • HF [137] • OSA [138] • JVP [139] • Venous occlusion [140] • Obstructive hypertrophic cardiomyopathy [141] • Arterial compliance [143]”
BackgroundGuo, Y., Wang, H., Zhang, H., Chen, Y., & Lip, G. Y. H. (2020) · Journal of Clinical Medicine · doi:10.3390/jcm9051493 · Cited by 41 · cited 2×
“An interesting AFib risk score assessment is developed in Huawei Heart Study on 644,124 individuals [211].”
BackgroundMethodLuguern, D., Macwan, R., Benezeth, Y., Moser, V., Dunbar, L. A., Braun, F., Lemkaddem, A., & Dubois, J. (2020) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2020.102263 · Cited by 41 · cited 2×
“Respiration rate [70,71,110] [68,112] [111]”
MethodPulseCam: a camera-based, motion-robust and highly sensitive blood perfusion imaging modality
Kumar, M., Suliburk, J. W., Veeraraghavan, A., & Sabharwal, A. (2020) · Scientific Reports · doi:10.1038/s41598-020-61576-0 · Cited by 40
Correia, B., Dias, N. S., Costa, P., & Pêgo, J. M. (2020) · Sensors · doi:10.3390/s20143905 · Cited by 39 · cited 1×
“A PPG earlobe sensor was used to monitor PRV induced by mental stress [170].”
MethodAssessing Drivers’ Physiological Responses Using Consumer Grade Devices
Gruden, T., Stojmenova, K., Sodnik, J., & Jakus, G. (2019) · Applied Sciences · doi:10.3390/app9245353 · Cited by 38
Baldoumas, G., Peschos, D., Tatsis, G., Chronopoulos, S. K., Christofilakis, V., Kostarakis, P., Varotsos, P. A., Sarlis, N. V., Skordas, E. S., Bechlioulis, A., et al. (2019) · Electronics · doi:10.3390/electronics8111288 · Cited by 38 · cited 2×
“Diagnosis CVDs • Cardiac output [136,142] • HF [137] • OSA [138] • JVP [139] • Venous occlusion [140] • Obstructive hypertrophic cardiomyopathy [141] • Arterial compliance [143]”
MethodFully-Automatic Camera-Based Pulse-Oximetry During Sleep
Vogels, T., van Gastel, M., Wang, W., & de Haan, G. (2018) · IEEE/CVF Conference on Computer Vision and Pattern Recognition Workshops (CVPRW) · doi:10.1109/cvprw.2018.00183 · Cited by 38 · cited 2×
“Sleep disorders [42,132,138,146,147] [145].”
BackgroundSpeckleplethysmographic (SPG) Estimation of Heart Rate Variability During an Orthostatic Challenge
Dunn, C. E., Monroe, D. C., Crouzet, C., Hicks, J. W., & Choi, B. (2019) · Scientific Reports · doi:10.1038/s41598-019-50526-0 · Cited by 37 · cited 2×
“Multiple papers [93,94,96] estimate BP using PPG in the Orthostatic hypotension test.”
MethodPhotoplethysmography for the Assessment of Haemorheology
Njoum, H., & Kyriacou, P. A. (2017) · Scientific Reports · doi:10.1038/s41598-017-01636-0 · Cited by 37 · cited 2×
“There are other medical applications of PPG waveform that have not gained much attention, like fertility monitoring [220], end-organ damage [53], wound healing prediction [221], and hematologic disorder [222].”
BackgroundKim, J., Choi, J.-K., Choi, M.-G., Ji, M., Hwang, G., Ko, S., & Bae, H.-M. (2018) · Scientific Reports · doi:10.1038/s41598-018-31685-y · Cited by 37
Wang, L., Poon, C. C. Y., & Zhang, Y. (2010) · Physiological Measurement · doi:10.1088/0967-3334/31/5/008 · Cited by 36 · cited 3×
“Diagnosis CVDs • Cardiac output [136,142] • HF [137] • OSA [138] • JVP [139] • Venous occlusion [140] • Obstructive hypertrophic cardiomyopathy [141] • Arterial compliance [143]”
BackgroundArnold, N., Gori, T., Schnabel, R. B., Schulz, A., Prochaska, J. H., Zeller, T., Binder, H., Pfeiffer, N., Beutel, M. E., Espinola–Klein, C., et al. (2017) · Scientific Reports · doi:10.1038/s41598-017-06175-2 · Cited by 36 · cited 20×
“Cardiovascular Diseases (CVDs) According to World Health Organization (WHO), cardiovascular diseases (CVDs), are the leading cause of death globally.”
BackgroundInfluentialKamshilin, A. A., Zaytsev, V. V., & Mamontov, O. V. (2017) · Scientific Reports · doi:10.1038/s41598-017-00552-7 · Cited by 36
Evaluating Photoplethysmogram as a Real-Time Cognitive Load Assessment during Game Playing
Zhang, X., Lyu, Y., Hu, X., Hu, Z., Shi, Y., & Yin, H. (2018) · International Journal of Human-Computer Interaction · doi:10.1080/10447318.2018.1461763 · Cited by 35 · cited 1×
“Cognitive load increases with the challenging level of a game; PPG signals can measure cognitive load during video game playing [172].”
BackgroundNon-contact imaging of peripheral hemodynamics during cognitive and psychological stressors
McDuff, D., Nishidate, I., Nakano, K., Haneishi, H., Aoki, Y., Tanabe, C., Niizeki, K., & Aizu, Y. (2020) · Scientific Reports · doi:10.1038/s41598-020-67647-6 · Cited by 35 · cited 1×
“iPPG system can be used to measure peripheral hemodynamics during psychological stress without contact [27].”
MethodRimsza, M. E., Hotaling, A. J., Keown, M. E., Marcin, J. P., Moskowitz, W. B., Sigrest, T. D., & Simon, H. K. (2015) · PEDIATRICS · doi:10.1542/peds.2015-0056 · Cited by 35 · cited 1×
“Children differ from adults in many health measurements aspects [182].”
BackgroundLei, R., Ling, B. W., Feng, P., & Chen, J. (2020) · Sensors · doi:10.3390/s20113238 · Cited by 34 · cited 1×
“Many methods were proposed to extract RR from PPG signal [70,71,110,111] and a real-time estimation of RR from PPG is presented in [70].”
MethodBousefsaf, F., Djeldjli, D., Ouzar, Y., Maaoui, C., & Pruski, A. (2021) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2021.104860 · Cited by 33
Alterations of blood pulsations parameters in carotid basin due to body position change
Kamshilin, A. A., Krasnikova, T. V., Volynsky, M. A., Miridonov, S. V., & Mamontov, O. V. (2018) · Scientific Reports · doi:10.1038/s41598-018-32036-7 · Cited by 33
Analysis and improvement of non-contact SpO2 extraction using an RGB webcam
Wei, B., Wu, X., Zhang, C., & Lv, Z. (2021) · Biomedical Optics Express · doi:10.1364/boe.423508 · Cited by 32
Park, C., & Lee, B. (2014) · BioMedical Engineering OnLine · doi:10.1186/1475-925x-13-170 · Cited by 31 · cited 1×
“Many methods were proposed to extract RR from PPG signal [70,71,110,111] and a real-time estimation of RR from PPG is presented in [70].”
MethodBradke, B. S., & Everman, B. (2020) · Biosensors · doi:10.3390/bios10040034 · Cited by 31 · cited 12×
“Measuring patient SpO2 using a finger is a standard practice in inpatient monitoring or outpatient checkup.”
BackgroundInfluentialNon-contact Quantification of Jugular Venous Pulse Waveforms from Skin Displacements
Tang, E. J. L. P., HajiRassouliha, A., Nash, M. P., Nielsen, P. M. F., Taberner, A. J., & Çakmak, Y. Ö. (2018) · Scientific Reports · doi:10.1038/s41598-018-35483-4 · Cited by 30
Increased arterial vascular tone during the night in patients with essential hypertension
Scholze, A., Burkert, A., Mardanzai, K., Suvd-Erdene, S., Hausberg, M., Zidek, W., & Tepel, M. (2006) · Journal of Human Hypertension · doi:10.1038/sj.jhh.1002097 · Cited by 29 · cited 20×
“The vascular tone was continuously measured using PPG and was found to be higher in hypertension patients [105].”
MethodInfluentialAssociation of remote imaging photoplethysmography and cutaneous perfusion in volunteers
Rasche, S., Huhle, R., Junghans, E., de Abreu, M. G., Yao, L., Trumpp, A., & Zaunseder, S. (2020) · Scientific Reports · doi:10.1038/s41598-020-73531-0 · Cited by 29
Foo, J. Y. A., Wilson, S. J., Williams, G. M., Harris, M., & Cooper, D. M. L. (2005) · Journal of Human Hypertension · doi:10.1038/sj.jhh.1001891 · Cited by 28 · cited 1×
“PTT derived from PPG can be used as a noninvasive measure of cardiovascular risk, especially in infants and toddlers [187].”
MethodPerpetuini, D., Chiarelli, A. M., Maddiona, L., Rinella, S., Bianco, F., Bucciarelli, V., Gallina, S., Perciavalle, V., Vinciguerra, V., Merla, A., et al. (2019) · Sensors · doi:10.3390/s19245570 · Cited by 28 · cited 23×
“Cardiovascular Diseases (CVDs) According to World Health Organization (WHO), cardiovascular diseases (CVDs), are the leading cause of death globally.”
BackgroundMethodInfluentialStress Classification Using Photoplethysmogram-Based Spatial and Frequency Domain Images
Elzeiny, S., & Qaraqe, M. (2020) · Sensors · doi:10.3390/s20185312 · Cited by 28 · cited 1×
“A person’s stress state was classified using convolution neural networks [171].”
MethodKiselev, A. R., Borovkova, E. I., Shvartz, V. A., Skazkina, V. V., Karavaev, A. S., Prokhorov, M. D., Ispiryan, A., Mironov, S. A., & Bockeria, O. L. (2020) · Scientific Reports · doi:10.1038/s41598-020-58196-z · Cited by 27 · cited 6×
“A PPG earlobe sensor was used to monitor PRV induced by mental stress [170].”
BackgroundInfluentialCamera-based assessment of arterial stiffness and wave reflection parameters from neck micro-motion
Moço, A., Mondragon, L. Z., Wang, W., Stuijk, S., & de Haan, G. (2017) · Physiological Measurement · doi:10.1088/1361-6579/aa7d43 · Cited by 27 · cited 1×
“Arterial stiffness [41,113–115,117–121,123] [35,126] [45,46,56,57,116]”
Perpetuini, D., Chiarelli, A. M., Cardone, D., Rinella, S., Massimino, S., Bianco, F., Bucciarelli, V., Vinciguerra, V., Fallica, G., Perciavalle, V., et al. (2020) · Applied Sciences · doi:10.3390/app10062137 · Cited by 27 · cited 1×
“However, some studies focused on its ability to indicate arterial stiffness [128,129].”
BackgroundIntraoperative Imaging of Cortical Blood Flow by Camera-Based Photoplethysmography at Green Light
Mamontov, O. V., Shcherbinin, A. V., Владимирович, Р. Р., & Kamshilin, A. A. (2020) · Applied Sciences · doi:10.3390/app10186192 · Cited by 27
Tabara, Y., Igase, M., Okada, Y., Nagai, T., Miki, T., Ohyagi, Y., Matsuda, F., & Kohara, K. (2016) · Hypertension Research · doi:10.1038/hr.2016.18 · Cited by 27 · cited 3×
“There are other medical applications of PPG waveform that have not gained much attention, like fertility monitoring [220], end-organ damage [53], wound healing prediction [221], and hematologic disorder [222].”
BackgroundWilson, K. A., James, G. A., Kilts, C., & Bush, K. (2020) · Scientific Reports · doi:10.1038/s41598-020-66109-3 · Cited by 26 · cited 2×
“, electrocutaneous [206], heat [207], stimuli images [208], and pain provoked in a social experiment [209].”
BackgroundMethodMillán, C. A., Girón, N. A., & López, D. M. (2020) · International Journal of Environmental Research and Public Health · doi:10.3390/ijerph17020498 · Cited by 26 · cited 1×
“Some of them focus on the specific medical use of PPG like pulse rate [3], blood pressure [4,5], atrial fibrillation [6,7], circulatory monitoring [8], nociception [9], or on the specific placement of PPG [10,11], others instead focused on reviewing the way that the signal has been analyzed [7,12–16] or the type of th…”
BackgroundAlmeneessier, A. S., Alshahrani, M. M., Aleissi, S. A., Hammad, O., Olaish, A. H., & BaHammam, A. S. (2020) · Scientific Reports · doi:10.1038/s41598-020-60281-2 · Cited by 25 · cited 23×
“Cardiovascular Diseases (CVDs) According to World Health Organization (WHO), cardiovascular diseases (CVDs), are the leading cause of death globally.”
BackgroundMethodInfluentialSelf-citationHEART RATE VARIABILITY MEASUREMENT USING THE SECOND DERIVATIVE PHOTOPLETHYSMOGRAM
Elgendi, M., Jonkman, M., & Boer, F. D. (2010) · International Conference on Bio-inspired Systems and Signal Processing · doi:10.5220/0002743300820087 · Cited by 24
Wei, H., Ta, N., Hu, W.-R., Wang, S., Xiao, M., Tang, X., Chen, J.-J., & Wu, H. (2020) · Diagnostics · doi:10.3390/diagnostics10010032 · Cited by 24 · cited 2×
“Monitoring OPD • CVDs [180,181] • Peripheral neuropathy [149] • Dementia [54,58]”
BackgroundAbnousi, F., Kang, G., Giacomini, J. C., Yeung, A. C., Zarafshar, S., Vesom, N., Ashley, E. A., Harrington, R. A., & Yong, C. M. (2019) · npj Digital Medicine · doi:10.1038/s41746-019-0159-0 · Cited by 24 · cited 5×
“The standard golden method to extract JVP is invasive central venous line catheterization.”
MethodInfluentialChen, L., Reisner, A. T., Gribok, A. V., & Jaques Reifman, A. (2010) · Shock · doi:10.1097/shk.0b013e3181dc07da · Cited by 24
Park, Y.-J., Lee, J.-M., & Kwon, S.-H. (2019) · Medicine · doi:10.1097/md.0000000000018091 · Cited by 24 · cited 4×
“Several studies [45,47,49] show that SDPTG is significantly associated with CVD.”
BackgroundInfluentialBonafini, S., Giontella, A., Tagetti, A., Montagnana, M., Benati, M., Danese, E., Minuz, P., Maffeis, C., Antoniazzi, F., & Fava, C. (2019) · Hypertension Research · doi:10.1038/s41440-018-0173-7 · Cited by 23 · cited 4×
“Pediatrics • PRV [183,185] • BP [181,186] • CVD [187–189] • RR [190,191] • PDA [192] • Vital signs [193]”
BackgroundInfluentialImpaired Microvascular Perfusion Improves With Increased Incubator Temperature in Preterm Infants
Genzel‐Boroviczény, O., Seidl, T., Rieger‐Fackeldey, E., Abicht, J., & Christ, F. (2007) · Pediatric Research · doi:10.1203/pdr.0b013e31802d77a2 · Cited by 22 · cited 1×
“Monitoring NICU patients’ cardiovascular [188,189], respiratory [190], and circulatory parameters [189,191] is possible through PPG oximeter.”
BackgroundWei, H., Xiao, M., Chen, H.-Y., Li, Y.-Q., Wu, H., & Sun, C. (2018) · Scientific Reports · doi:10.1038/s41598-018-34091-6 · Cited by 22
On Time Domain Analysis of Photoplethysmogram Signals for Monitoring Heat Stress
Elgendi, M., Fletcher, R., Norton, I., Brearley, M. B., Abbott, D., Lovell, N. H., & Schuurmans, D. (2015) · Sensors · doi:10.3390/s151024716 · Cited by 22 · cited 1×
“, electrocutaneous [206], heat [207], stimuli images [208], and pain provoked in a social experiment [209].”
BackgroundWieler, M. E., Murphy, T. G., Blecherman, M., Mehta, H., & Bender, G. J. (2021) · Journal of Perinatology · doi:10.1038/s41372-021-00967-1 · Cited by 22 · cited 2×
“Pediatrics [181,184,186–190,192,193] [78,191] -”
BackgroundIs Heart Rate a Confounding Factor for Photoplethysmography Markers? A Systematic Review
Lazim, M. R. M. L. M., Aminuddin, A., Chellappan, K., Ugusman, A., Hamid, A. A., Ahmad, W. A. N. W., & Mohamad, M. S. F. (2020) · International Journal of Environmental Research and Public Health · doi:10.3390/ijerph17072591 · Cited by 22
Reliable Detection of Atrial Fibrillation with a Medical Wearable during Inpatient Conditions
Jacobsen, M., Dembek, T. A., Ziakos, A. P., Gholamipoor, R., Kobbe, G., Kollmann, M., Blum, C. F., Müller‐Wieland, D., Napp, A., Heinemann, L., et al. (2020) · Sensors · doi:10.3390/s20195517 · Cited by 21 · cited 1×
“Detecting AFib using wearable devices is a feasible and reliable approach during inpatient physical activity [214] or free-living conditions [180,215,216].”
Contactless Monitoring of Microcirculation Reaction on Local Temperature Changes
Volynsky, M. A., Борисович, М. Н., Mamontov, O. V., & Kamshilin, A. A. (2019) · Applied Sciences · doi:10.3390/app9224947 · Cited by 21 · cited 2×
“Microcirculatory • Perfusion change [28,32,130] -”
MethodCho, J., & Baek, H. J. (2020) · Sensors · doi:10.3390/s20072073 · Cited by 21
Post‐challenge hyperglycaemia is an independent risk factor for arterial stiffness in Japanese men
Ohshita, K., Yamane, K., Ishida, K., Watanabe, H., Okubo, M., & Kohno, N. (2004) · Diabetic Medicine · doi:10.1111/j.1464-5491.2004.01161.x · Cited by 18 · cited 3×
“Arterial stiffness • Aging [45,57,113–115] • PWV [117] • SI [41,118] • CVD [56,122] • Vascular aging [116] • SI [46,123] • Cardiovascular risk [123] • SI [119,121] • AIX [120]”
BackgroundAndriessen, P., Schraa, O., van den Bosch-Ruis, W., Harkel, D. J. T., Settels, J. J., Oetomo, S. B., & Blanco, C. E. (2008) · Pediatric Research · doi:10.1203/pdr.0b013e31816c8fe3 · Cited by 18
Mayampurath, A. M., Volchenboum, S. L., & Sanchez-Pinto, L. N. (2018) · npj Digital Medicine · doi:10.1038/s41746-018-0038-0 · Cited by 17 · cited 6×
“A PPG earlobe sensor was used to monitor PRV induced by mental stress [170].”
BackgroundInfluentialPrabhakar, S. K., Rajaguru, H., & Kim, S. (2020) · Diagnostics · doi:10.3390/diagnostics10100763 · Cited by 17 · cited 3×
“Diagnosis CVDs • Cardiac output [136,142] • HF [137] • OSA [138] • JVP [139] • Venous occlusion [140] • Obstructive hypertrophic cardiomyopathy [141] • Arterial compliance [143]”
MethodKawada, T., & Otsuka, T. (2013) · Diabetes & Metabolism Journal · doi:10.4093/dmj.2013.37.1.40 · Cited by 17
Feasibility of monitoring vascular ageing by multi-site photoplethysmography
Maria, C. D., Sharkey, E., Klinge, A., Zheng, D., Murray, A., O’Sullivan, J. J., & Allen, J. (2012) · doi:10.25405/ncl.34197837 · Cited by 15
Remer, I., & Bilenca, A. (2015) · Journal of Biophotonics · doi:10.1002/jbio.201500156 · Cited by 15
Monitoring Neonatal Peripheral Circulation by Electrocardiogram-to-Oximeter Pulse Velocity
Oishi, M., Nishida, H., Kabe, K., & Hoshi, J. (1993) · Pediatric Research · doi:10.1203/00006450-199306000-00024 · Cited by 14 · cited 1×
“Monitoring NICU patients’ cardiovascular [188,189], respiratory [190], and circulatory parameters [189,191] is possible through PPG oximeter.”
BackgroundWei, H., Ta, N., Hu, W.-R., Xiao, M., Tang, X., Haryadi, B., Liou, J. J., & Wu, H. (2019) · Entropy · doi:10.3390/e21121229 · Cited by 14
A Non-Contact Photoplethysmography Technique for the Estimation of Heart Rate via Smartphone
Maestre, R., Rivera-Roman, T. A., Fernandez-Jaramillo, A. A., Guerrón, N., & Olmedo, J. J. S. (2019) · Applied Sciences · doi:10.3390/app10010154 · Cited by 14 · cited 1×
“In contact PPG [60–62], pulse rate is measured by placing a finger on the phone rear camera while, in non-contact [33,34,63], iPPG is extracted from the face, without the need for direct skin contact.”
BackgroundAmirtharaj, C., Palmeri, L. C., Gradwohl, G., Adar, Y., Nitzan, M., Gruber, D., Blaufox, A. D., Meyer, D. B., Kwon, E. N., & Koppel, R. I. (2018) · Journal of Perinatology · doi:10.1038/s41372-018-0165-0 · Cited by 13 · cited 2×
“Pulse transit time of PPG may aid in evaluating Patent Ductus Arteriosus (PDA) status in preterm infants [192].”
BackgroundBlood Pressure Estimation Algorithm Based on Photoplethysmography Pulse Analyses
Kim, S.-C., & Cho, S.-H. (2020) · Applied Sciences · doi:10.3390/app10124068 · Cited by 12
Convergence of physiological responses to pain during face-to-face interaction
Murata, A., Nishida, H., Watanabe, K., & Kameda, T. (2020) · Scientific Reports · doi:10.1038/s41598-019-57375-x · Cited by 11 · cited 1×
“, electrocutaneous [206], heat [207], stimuli images [208], and pain provoked in a social experiment [209].”
BackgroundRapalis, A., Janušauskas, A., Marozas, V., & Lukoševičius, A. (2016) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2016.10.014 · Cited by 11 · cited 2×
“Multiple papers [93,94,96] estimate BP using PPG in the Orthostatic hypotension test.”
MethodPrognosis of Diabetic Peripheral Neuropathy via Decomposed Digital Volume Pulse from the Fingertip
Wei, H., Hu, W.-R., Ta, N., Xiao, M., Tang, X., & Wu, H. (2020) · Entropy · doi:10.3390/e22070754 · Cited by 10
Kukel, I., Trumpp, A., Plötze, K., Rost, A., Zaunseder, S., Matschke, K., & Rasche, S. (2020) · Applied Sciences · doi:10.3390/app10186537 · Cited by 10 · cited 2×
“Surgery • Anesthesia [55,194] • PRV [195] • Blood perfusion [30,179,196,197]”
MethodWu, J., Chen, G.-C., Wu, M., Lin, C., & Chen, T. (2016) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-016-1503-z · Cited by 9 · cited 7×
“A combination of PPG and acoustic Doppler analysis provides a reliable method for arterial steal syndrome (ASS) and arteriovenous fistulas stenosis detection in patients receiving hemodialysis [134].”
BackgroundMethodInfluentialLive Demonstration: A Single LED PPG-Based Noninvasive Glucose Monitoring Prototype System
Hina, A., Nadeem, H., Aslam, A. R., & Saadeh, W. (2019) · IEEE International Symposium on Circuits and Systems proceedings · doi:10.1109/iscas.2019.8702241 · Cited by 8 · cited 2×
“With the aid of machine learning techniques, PPG shows advances in measuring glucose levels [157,158].”
MethodIwamoto, T., Kanetaka, H., Takasaki, M., & Takazawa, K. (2003) · Geriatrics and gerontology international/Geriatrics & gerontology international · doi:10.1111/j.1444-1586.2003.00086.x · Cited by 8 · cited 5×
“Neuro • Dementia [54,58] • Multiple sclerosis [205] • Pain [206–209]”
BackgroundInfluential(2020) · doi:10.3390/s20164528 · Cited by 6 · cited 1×
“‘Heartbeats’ is a system designed to produce different kinds of music based on synchronized PPG, based on the claim that music can enhance athletic performance [219].”
BackgroundNader, J. A., Manrique-Mirón, P. C., Pino-Peña, Y., Andrade-Magdaleno, M. L., & López-Estrada, J. (2020) · Scientific Reports · doi:10.1038/s41598-020-70701-y · Cited by 5 · cited 3×
“Automatic Nervous system • Electrical activity in the brain [37] • Syncope [38] -”
BackgroundInfluentialComparison of the light charged particles on scatter radiation dose in thyroid hadron therapy.
Azizi, M., & Mowlavi, A. (2014) · PubMed Central · Cited by 5
Lee, I. H., Choi, C.-J., Kim, C. M., Yoon, S. A., Hong, J. Y., & Kim, J. Y. (2010) · Korean Journal of Family Medicine · doi:10.4082/kjfm.2010.31.9.679 · Cited by 3
Miyashita, H. (2016) · Hypertension Research · doi:10.1038/hr.2016.175 · Cited by 3 · cited 1×
“It was found that there is a noticeable association between the SDPTG and cardiovascular mortality [51].”
Background
Cited by
Wearable Devices for Physical Monitoring of Heart: A Review
Prieto-Avalos, G., Cruz-Ramos, N. A., Alor-Hernández, G., Sánchez-Cervantes, J. L., Rodríguez-Mazahua, L., & Guarneros-Nolasco, L. R. (2022) · Biosensors · doi:10.3390/bios12050292 · Cited by 239
“From the reading of the reflected light rays, the percentage of oxygen in the blood is calculated [64].”
BackgroundA PPG Signal Dataset Collected in Semi-Naturalistic Settings Using Galaxy Watch
Park, S., Zheng, D., & Lee, U. (2025) · Scientific Data · doi:10.1038/s41597-025-05152-z · Cited by 12
Metadata
- Authors
- Almarshad, M. A., Islam, M. S., Al-Ahmadi, S., & BaHammam, A. S.
- Venue
- Healthcare
- Publisher
- MDPI AG
- Published
- 2022-03-16
- Volume
- 10
- Issue
- 3
- Pages
- 547
- ISSN
- 2227-9032 (ISSN-L)
- OpenAlex
- W4221007892
- Cited by
- 188
- References
- 202
- FWCI
- 3.99
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.