The DOI matches its Crossref record; 48 of the 48 references it cites were found in a registry or an index.
Current Strategies to Improve the Bioactivity of PEEK
Open accessAbstract
The synthetic thermoplastic polymer polyetheretherketone (PEEK) is becoming a popular component of clinical orthopedic and spinal applications, but its practical use suffers from several limitations. Although PEEK is biocompatible, chemically stable, radiolucent and has an elastic modulus similar to that of normal human bone, it is biologically inert, preventing good integration with adjacent bone tissues upon implantation. Recent efforts have focused on increasing the bioactivity of PEEK to improve the bone-implant interface. Two main strategies have been used to overcome the inert character of PEEK. One approach is surface modification to activate PEEK through surface treatment alone or in combination with a surface coating. Another strategy is to prepare bioactive PEEK composites by impregnating bioactive materials into PEEK substrate. Researchers believe that modified bioactive PEEK will have a wide range of orthopedic applications.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
How useful is SBF in predicting in vivo bone bioactivity?
Kokubo, T., & Takadama, H. (2006) · Biomaterials · doi:10.1016/j.biomaterials.2006.01.017 · Cited by 9,576
A 15-year study of osseointegrated implants in the treatment of the edentulous jaw
Adell, R., Lekholm, U., Rockler, B., & Brånemark, P.-I. (1981) · International Journal of Oral Surgery · doi:10.1016/s0300-9785(81)80077-4 · Cited by 4,816
PEEK biomaterials in trauma, orthopedic, and spinal implants
Kurtz, S. M., & Devine, J. N. (2007) · Biomaterials · doi:10.1016/j.biomaterials.2007.07.013 · Cited by 2,388
An Introduction to Bioceramics
Hench, L. L., & Wilson, J. (1993) · WORLD SCIENTIFIC eBooks · doi:10.1142/2028 · Cited by 2,307
Calcium Phosphate Ceramics as Hard Tissue Prosthetics
JARCHO, M. (1981) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-198106000-00037 · Cited by 2,014
Novel bioactive materials with different mechanical properties
Kokubo, T., Kim, H.-M., & Kawashita, M. (2003) · Biomaterials · doi:10.1016/s0142-9612(03)00044-9 · Cited by 1,914
Biomedical applications of polymer-composite materials: a review
Ramakrishna, S., Mayer, J., Wintermantel, E., & Leong, K. W. (2001) · Composites Science and Technology · doi:10.1016/s0266-3538(00)00241-4 · Cited by 1,642
Enhanced functions of osteoblasts on nanophase ceramics
Webster, T. (2000) · Biomaterials · doi:10.1016/s0142-9612(00)00075-2 · Cited by 1,324
HUISKES, R., WEINANS, H., & RIETBERGEN, B. V. (1992) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-199201000-00014 · Cited by 1,213
Osteoblast adhesion on nanophase ceramics
Webster, T. J., Siegel, R. W., & Bizios, R. (1999) · Biomaterials · doi:10.1016/s0142-9612(99)00020-4 · Cited by 926
Handbook of Biomaterial Properties
Black, J. T. (1998) · Springer eBooks · doi:10.1007/978-1-4615-5801-9 · Cited by 734
Tan, K. H., Chua, C. K., Leong, K. F., Cheah, C. M., Cheang, P., Abu Bakar, M. S., & Cha, S. W. (2003) · Biomaterials · doi:10.1016/s0142-9612(03)00131-5 · Cited by 625
Titanium: The implant material of today
van Noort, R. (1987) · Journal of Materials Science · doi:10.1007/bf01133326 · Cited by 485
Enhanced osteoclast-like cell functions on nanophase ceramics
Webster, T. (2001) · Biomaterials · doi:10.1016/s0142-9612(00)00285-4 · Cited by 445
Zhao, Y., Wong, H. M., Wang, W., Li, P., Xu, Z., Chong, E. Y. W., Yan, C. H., Yeung, K. W. K., & Chu, P. K. (2013) · Biomaterials · doi:10.1016/j.biomaterials.2013.08.071 · Cited by 387
Plasma Treatment for Improved Bonding: A Review
Liston, E. M. (1989) · The Journal of Adhesion · doi:10.1080/00218468908048206 · Cited by 362
Bioactive composite materials for tissue engineering scaffolds
Boccaccini, A. R., & Blaker, J. J. (2005) · Expert Review of Medical Devices · doi:10.1586/17434440.2.3.303 · Cited by 347
Nanofiller‐reinforced polymer nanocomposites
Njuguna, J., Pielichowski, K., & Desai, S. (2008) · Polymers for Advanced Technologies · doi:10.1002/pat.1074 · Cited by 327
Stevens, B., Yang, Y., Mohandas, A., Stucker, B., & Nguyen, K. T. (2008) · Journal of Biomedical Materials Research Part B: Applied Biomaterials · doi:10.1002/jbm.b.30962 · Cited by 326
High-performance nanocomposites based on polyetherketones
Díez-Pascual, A. M., Naffakh, M., Marco, C., Ellis, G., & Gómez-Fatou, M. A. (2012) · Progress in Materials Science · doi:10.1016/j.pmatsci.2012.03.003 · Cited by 289
Yu, S., Hariram, K. P., Kumar, R., Cheang, P., & Aik, K. K. (2005) · Biomaterials · doi:10.1016/j.biomaterials.2004.07.028 · Cited by 228
Lee, J. H., Jang, H. L., Lee, K. M., Baek, H.-R., Jin, K., Hong, K. S., Noh, J. H., & Lee, H.-K. (2013) · Acta Biomaterialia · doi:10.1016/j.actbio.2012.11.030 · Cited by 219
In vivo biocompatibility testing of peek polymer for a spinal implant system: A study in rabbits
Rivard, C., Rhalmi, S., & Coillard, C. (2002) · Journal of Biomedical Materials Research · doi:10.1002/jbm.10159 · Cited by 182
Processing and tensile properties of hydroxyapatite-whisker-reinforced polyetheretherketone
Converse, G. L., Yue, W., & Roeder, R. K. (2007) · Biomaterials · doi:10.1016/j.biomaterials.2006.10.031 · Cited by 169
Nano‐hydroxyapatite‐coated PEEK implants: A pilot study in rabbit bone
Barkarmo, S., Wennerberg, A., Hoffman, M., Kjellin, P., Breding, K., Handa, P., & Stenport, V. F. (2012) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.34358 · Cited by 148
Nonresorbable polymers in bone surgery
Eschbach, L. (2000) · Injury · doi:10.1016/s0020-1383(00)80019-4 · Cited by 148
Hydroxyapatite-reinforced polymer biocomposites for synthetic bone substitutes
Roeder, R. K., Converse, G. L., Kane, R. J., & Yue, W. (2008) · JOM · doi:10.1007/s11837-008-0030-2 · Cited by 148
Biological Evaluation of Bioceramic Materials- A Review
Thamaraiselvi, T., & Rajeswari, S. (2014) · Cited by 145
Ha, S., Kirch, M., Birchler, F., Eckert, K.-L., Mayer, J., Wintermantel, E., Sittig, C., PFUND-KLINGENFUSS, I., Textor, M., Spencer, N. D., et al. (1997) · Journal of Materials Science Materials in Medicine · doi:10.1023/a:1018535923173 · Cited by 138
Hydroxyapatite whisker-reinforced polyetherketoneketone bone ingrowth scaffolds
Converse, G. L., Conrad, T. L., Merrill, C. H., & Roeder, R. K. (2009) · Acta Biomaterialia · doi:10.1016/j.actbio.2009.08.004 · Cited by 127
Osteoconductive hydroxyapatite coated PEEK for spinal fusion surgery
Hahn, B., Park, D.-S., Choi, J., Ryu, J., Yoon, W., Choi, J., Kim, J., Ahn, C., Kim, H., Yoon, B., et al. (2013) · Applied Surface Science · doi:10.1016/j.apsusc.2013.05.073 · Cited by 125
Processing and evaluation of bioactive coatings on polymeric implants
Rabiei, A., & Sandukas, S. (2013) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.34557 · Cited by 121
Design and evaluation of nanophase alumina for orthopaedic/dental applications
Webster, T. J., Siegel, R. W., & Bizios, R. (1999) · Nanostructured Materials · doi:10.1016/s0965-9773(99)00283-4 · Cited by 121
Fibronectin adsorption or/and covalent grafting on chemically modified PEEK film surfaces
Noiset, O., Schneider, Y., & Marchand‐Brynaert, J. (1999) · Journal of Biomaterials Science Polymer Edition · doi:10.1163/156856299x00865 · Cited by 118
Shi, X. C., Hudson, J. L., Spicer, P. P., Tour, J. M., Krishnamoorti, R., & Mikos, A. G. (2005) · Nanotechnology · doi:10.1088/0957-4484/16/7/030 · Cited by 113
Horch, R. A., Shahid, N., Mistry, A. S., Timmer, M. D., Mikos, A. G., & Barron, A. R. (2004) · Biomacromolecules · doi:10.1021/bm049768s · Cited by 110
Nanotopography: Cellular Responses to Nanostructured Materials
Kriparamanan, R., Aswath, P. B., Zhou, A., Tang, L., & Nguyen, K. T. (2006) · Journal of Nanoscience and Nanotechnology · doi:10.1166/jnn.2006.330 · Cited by 108
Devine, D. M., Hahn, J., Richards, R. G., Gruner, H., Wieling, R., & Pearce, S. G. (2012) · Journal of Biomedical Materials Research Part B Applied Biomaterials · doi:10.1002/jbm.b.32861 · Cited by 101
Differentiation of human mesenchymal stem cells on plasma-treated polyetheretherketone
Waser-Althaus, J., Salamon, A., Waser, M., Padeste, C., Kreutzer, M., Pieles, U., Müller, B., & Peters, K. (2013) · Journal of Materials Science Materials in Medicine · doi:10.1007/s10856-013-5072-5 · Cited by 99
Adhesion and growth of CaCo2 cells on surface-modified PEEK substrata
Noiset, O., Schneider, Y., & Marchand‐Brynaert, J. (2000) · Journal of Biomaterials Science Polymer Edition · doi:10.1163/156856200744002 · Cited by 86
Preliminary evaluation of titanium-coated PEEK dental implants.
Cook, S. D., & Rust-Dawicki, A. M. (1995) · PubMed · Cited by 80
Harle, J., Kim, H., Mordan, N., Knowles, J. C., & Salih, V. M. (2006) · Acta Biomaterialia · doi:10.1016/j.actbio.2006.05.005 · Cited by 76
von Wilmowsky, C., Vairaktaris, E. G., Pohle, D., et al. (2008) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.31822 · Cited by 76
A Nanoscale Adhesion Layer to Promote Cell Attachment on PEEK
Dennes, T. J., & Schwartz, J. (2009) · Journal of the American Chemical Society · doi:10.1021/ja810075c · Cited by 68
Jiya, T. U., Smit, T. H., Deddens, J. A., & Mullender, M. G. (2009) · Spine · doi:10.1097/brs.0b013e318194ed00 · Cited by 49
Jung, H., Park, H. S., Kang, M., Lee, S., Kim, H., Estrin, Y., & Koh, Y. (2013) · Materials Letters · doi:10.1016/j.matlet.2013.10.062 · Cited by 45
Tsou, H., Hsieh, P., Chung, C., Tang, C., Shyr, T., & He, J. (2009) · Surface and Coatings Technology · doi:10.1016/j.surfcoat.2009.06.018 · Cited by 37
Pohle, D., Ponader, S., Rechtenwald, T., et al. (2007) · Macromolecular Symposia · doi:10.1002/masy.200750708 · Cited by 33
Cited by
Shirazi, S. F. S., Gharehkhani, S., Mehrali, M., Yarmand, H., Metselaar, H. S. C., Adib Kadri, N., & Osman, N. A. A. (2015) · Science and Technology of Advanced Materials · doi:10.1088/1468-6996/16/3/033502 · Cited by 755
A Multimaterial Scaffold With Tunable Properties: Toward Bone Tissue Repair
Feng, P., Wu, P., Gao, C., Yang, Y., Guo, W., Yang, W., & Shuai, C. (2018) · Advanced Science · doi:10.1002/advs.201700817 · Cited by 365
Han, X., Yang, D., Yang, C., Spintzyk, S., Scheideler, L., Li, P., Li, D., Geis-Gerstorfer, J., & Rupp, F. (2019) · Journal of Clinical Medicine · doi:10.3390/jcm8020240 · Cited by 361
Honigmann, P., Sharma, N., Okolo, B., Popp, U., Msallem, B., & Thieringer, F. M. (2018) · BioMed Research International · doi:10.1155/2018/4520636 · Cited by 275
Liu, C., Li, Y., Wang, J., Liu, C., Liu, W., & Jian, X. (2018) · Molecules · doi:10.3390/molecules23071643 · Cited by 30
Metadata
- Authors
- Ma, R., & Tang, T.
- Venue
- International Journal of Molecular Sciences
- Publisher
- MDPI AG
- Published
- 2014-03-28
- Volume
- 15
- Issue
- 4
- Pages
- 5426-5445
- ISSN
- 1422-0067 (ISSN-L)
- OpenAlex
- W2069453298
- Cited by
- 491
- References
- 48
- FWCI
- 12.58
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.