Evolving the Era of 5D Ultrasound? A Systematic Literature Review on the Applications for Artificial Intelligence Ultrasound Imaging in Obstetrics and Gynecology
Open accessThe DOI matches its Crossref record; 231 of the 246 references it cites were found in a registry or an index; 263 of the 429 sources its claims cite were checked for support.
Abstract
A systematic literature review including 189 articles on AI applications in obstetrics and gynecology ultrasound imaging, with 148 focused on obstetrics.
Overview
CoChat Summary
## TL;DR
This systematic review mapped published AI applications in obstetric and gynecologic ultrasound and found far more studies in obstetrics than gynecology: 148 versus 41, out of 189 included articles. The paper concludes that AI can reduce exam time, workload, and variability, but most studies remain technical and have limited clinical applicability.
## Key findings
- The review included 189 articles published from 1994 to 2023; 148 focused on obstetrics and 41 on gynecology.
- In obstetrics, the most represented topics were fetal biometry, fetal echocardiography, neurosonography, gestational age estimation, and workflow analysis; in gynecology, major topics included adnexal masses, breast masses, endometrium, and pelvic floor.
- AI-assisted ultrasound was repeatedly reported to reduce examination time; for pelvic floor studies, reported time dropped from up to 15 minutes to 1.27 seconds.
- For gestational age estimation, the review reports high accuracy with an error of 3.9 to 5 days in some models, and for breast/ovarian mass work, some AI systems matched or outperformed human readers in the cited studies.
## Methods
- The authors conducted a systematic literature review in line with PRISMA, and prospectively registered it in PROSPERO (CRD42023434218).
- They searched PubMed and the Cochrane Library on 14 May 2023, screening English- and German-language records using a PICOS-based approach.
- Inclusion focused on studies using AI with ultrasound in obstetrics or gynecology; studies without AI or US, outside OB/GYN, or using only ultrasound-derived measurements rather than images were excluded.
## Limitations
- The paper states that many AI models still require expert input for image acquisition, ROI selection, and interpretation, and that most studies are technical/preliminary rather than clinically validated.
- The review notes that its search query included the extra keyword “pregnancy,” which likely biased retrieval toward obstetric studies. *(stated in the paper)*
- It also states that including many engineering-literature studies may limit clinical applicability, and that most models lack external validation, real-time use, and testing on pathologic or heterogeneous data. *(stated in the paper)*
Model-written summary. Check it against the paper before relying on it.
Integrity signals
Registry
Cites
Statistics
Figures



Verification
Claims the paper makes
175 Valid · 12 Not valid · 62 Not checked · 80 Own results and interpretations
At least one cited source doesn’t support this claim or points to a different paper, and none confirmed it — see the verdicts below.
In the paper
“slow processing times [35,43]”
§ Evolving the Era of 5D Ultrasound? A Systematic Literature Review on the Applications for Artificial Intelligence Ultrasound Imaging in Obstetrics and Gynecology > 3. Results > 3.2. Applications in Obstetrics
What the sources say
- Disputedcites [35] Heuvel T.L.v.D. Petros H. Santini S. de Korte C.L. van Ginneken B. Automated Fetal Head Detection and Circumference Estimation from Free-Hand Ultrasound Sweeps Using Deep Learning in Resource-Limited Countries Ultrasound Med. Biol. 2019 45 773 785 10.1016/j.ultrasmedbio.2018.09.015 30573305 sourceExperimental — accuracy not yet measured
The “Deployment on low-cost hardware” section says frame classification is fast enough for real-time computation on the study’s training hardware, rather than identifying slow AI processing as a limitation. The “Improvements” section identifies a different delay: the ultrasound device took one minute to save each sweep. (LLM, conf=0.84)
Checked by a reasoning model — may be wrong.
- Not checked — no full text of the sourcecites [43] Chen H. Ni D. Qin J. Li S. Yang X. Wang T. Heng P.A. Standard Plane Localization in Fetal Ultrasound via Domain Transferred Deep Neural Networks IEEE J. Biomed. Health Inform. 2015 19 1627 1636 10.1109/JBHI.2015.2425041 25910262 source
plain- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: unclear — It is unclear whether the paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Disputed
At least one cited source doesn’t support this claim or points to a different paper, and none confirmed it — see the verdicts below.
In the paper
“The image quality assessment of whether a standard plane was correctly acquired, either by human operators or by automated extraction from 3D images, was effectively performed by models developed by the research groups of Lin et al. [90], Yaqub et al. [91], and Skelton et al. [92].”
§ Evolving the Era of 5D Ultrasound? A Systematic Literature Review on the Applications for Artificial Intelligence Ultrasound Imaging in Obstetrics and Gynecology > 3. Results > 3.2. Applications in Obstetrics
What the sources say
- Not checked — no full text of the sourcecites [90] Lin Z. Li S. Ni D. Liao Y. Wen H. Du J. Chen S. Wang T. Lei B. Multi-task learning for quality assessment of fetal head ultrasound images Med. Image Anal. 2019 58 101548 10.1016/j.media.2019.101548 31525671 source
- Not checked — no full text of the sourcecites [91] Yaqub M. Kelly B. Papageorghiou A.T. Noble J.A. A Deep Learning Solution for Automatic Fetal Neurosonographic Diagnostic Plane Verification Using Clinical Standard Constraints Ultrasound Med. Biol. 2017 43 2925 2933 10.1016/j.ultrasmedbio.2017.07.013 28958729 source
- Disputedcites [92] Skelton E. Matthew J. Li Y. Khanal B. Martinez J.C. Toussaint N. Gupta C. Knight C. Kainz B. Hajnal J. Towards automated extraction of 2D standard fetal head planes from 3D ultrasound acquisitions: A clinical evaluation and quality assessment comparison Radiography 2021 27 519 526 10.1016/j.radi.2020.11.006 33272825 PMC8052189 sourceExperimental — accuracy not yet measured
The Methods (Quality assessment; page unavailable) state that two human observers assessed whether each plane was adequate. The model automatically extracted planes from 3D images; it did not perform the image-quality assessment attributed to it. (LLM, conf=0.88)
Checked by a reasoning model — may be wrong.
plainstates a cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: unclear — It is unclear whether the paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
Every source the paper cites for this claim was checked and supports it.
In the paper
“However, US imaging has limitations regarding its comparability and reproducibility.”
§ Evolving the Era of 5D Ultrasound? A Systematic Literature Review on the Applications for Artificial Intelligence Ultrasound Imaging in Obstetrics and Gynecology > 1. Introduction
What the sources say
- Supportedcites [4] Diniz P.H.B. Yin Y. Collins S. Deep Learning Strategies for Ultrasound in Pregnancy EMJ Reprod. Health 2020 6 73 80 10.33590/emjreprohealth/20-00100 PMC7590498 33123376 source
The Introduction says ultrasound has high inter- and intra-observer variability across different manufacturers’ machines. That directly supports the paraphrased limitations in reproducibility and comparability. (LLM, conf=0.91)
plain- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Supported
The sources with a verdict support this claim; the rest weren’t checked yet, have no full text we could read, or their verdicts aren’t rated yet.
In the paper
“the possibility of real-time applicability [15,25,32,33]”
§ Evolving the Era of 5D Ultrasound? A Systematic Literature Review on the Applications for Artificial Intelligence Ultrasound Imaging in Obstetrics and Gynecology > 3. Results > 3.2. Applications in Obstetrics
What the sources say
- Supportedcites [15] Baumgartner C.F. Kamnitsas K. Matthew J. Fletcher T.P. Smith S. Koch L.M. Kainz B. Rueckert D. SonoNet: Real-Time Detection and Localisation of Fetal Standard Scan Planes in Freehand Ultrasound IEEE Trans. Med. Imaging 2017 36 2204 2215 10.1109/TMI.2017.2712367 28708546 PMC6051487 source
The Abstract states that SonoNet’s convolutional network is designed to operate in real time when detecting fetal standard scan planes and reports a real-time detection experiment. The Introduction (Contributions) also says the system can provide real-time feedback to the operator. (LLM, conf=0.93)
- Supportedcites [25] Płotka S. Klasa A. Lisowska A. Seliga-Siwecka J. Lipa M. Trzciński T. Sitek A. Deep learning fetal ultrasound video model match human observers in biometric measurements Phys. Med. Biol. 2022 67 045013 10.1088/1361-6560/ac4d85 35051921 source
The Discussion says the automatic approach could be used in real time during routine fetal ultrasound examinations to help identify standard planes. It also notes that this would require installation on the ultrasound device and integration into the workflow; the claim is about the possibility, not an already deployed capability. (LLM, conf=0.93)
- Not checked — no full text of the sourcecites [32] Carneiro G. Georgescu B. Good S. Comaniciu D. Detection and Measurement of Fetal Anatomies from Ultrasound Images using a Constrained Probabilistic Boosting Tree IEEE Trans. Med. Imaging 2008 27 1342 1355 10.1109/TMI.2008.928917 18753047 source
- Not checked — no full text of the sourcecites [33] Luo D. Wen H. Peng G. Lin Y. Liang M. Liao Y. Qin Y. Zeng Q. Dang J. Li S. A Prenatal Ultrasound Scanning Approach: One-Touch Technique in Second and Third Trimesters Ultrasound Med. Biol. 2021 47 2258 2265 10.1016/j.ultrasmedbio.2021.04.020 34059375 source
hedgedstates a cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: unclear — It is unclear whether the paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Supported
The cited sources support only part of this claim — read each source’s verdict below.
In the paper
“the application of a lightweight algorithm in point-of-care devices [18,34,37]”
§ Evolving the Era of 5D Ultrasound? A Systematic Literature Review on the Applications for Artificial Intelligence Ultrasound Imaging in Obstetrics and Gynecology > 3. Results > 3.2. Applications in Obstetrics
What the sources say
- Not checked — no full text of the sourcecites [18] Zeng W. Luo J. Cheng J. Lu Y. Efficient fetal ultrasound image segmentation for automatic head circumference measurement using a lightweight deep convolutional neural network Med. Phys. 2022 49 5081 5092 10.1002/mp.15700 35536111 source
- Partly supportedcites [34] Zeng Y. Tsui P.-H. Wu W. Zhou Z. Wu S. Fetal Ultrasound Image Segmentation for Automatic Head Circumference Biometry Using Deeply Supervised Attention-Gated V-Net J. Digit. Imaging 2021 34 134 148 10.1007/s10278-020-00410-5 33483862 PMC7887128 sourceExperimental — accuracy not yet measured
The Discussion (page unavailable) describes point-of-care use as a potential application and reports a 6.3 ms execution time on a computer. The Introduction (page unavailable) says the attention modules add few parameters at low computational cost. The paper does not report applying the algorithm on point-of-care devices or using it to acquire standard planes; it studies head segmentation and circumference measurement from existing images. (LLM, conf=0.85)
- Not checked — no full text of the sourcecites [37] Yang C. Yang Z. Liao S. Guo J. Yin S. Liu C. Kang Y. A new approach to automatic measure fetal head circumference in ultrasound images using convolutional neural networks Comput. Biol. Med. 2022 147 105801 10.1016/j.compbiomed.2022.105801 35785663 source
plainstates a cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: unclear — It is unclear whether the paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
198 more claims · 120 with their cited sources checked
Create a free account to see all 329 claims and every source verdict.
- It may state two separate claims as one. 69
- Probably not a substantial claim. 69
- The quote only partly states this claim. 3
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
Self-check results appear here once an independent check has confirmed them.
Cited works that were retracted
Works this paper cites that were later retracted, from the retraction notices publishers deposit. Major when the notice came out before this paper was published.
Rated major: it would touch a result — a value a result rests on, reported and recomputed p-values on opposite sides of the significance level, two passages that conflict with no sign which is right, or a cited work retracted before this paper was published.
In the paper
“Zhang Y. Hou J. Wang Q. Hou A. Liu Y. Application of Transfer Learning and Feature Fusion Algorithms to Improve the Identification and Prediction Efficiency of Premature Ovarian Failure J. Healthc. Eng. 2022 2022 3269692 10.1155/2022/3269692 35388326 PMC8977322”
Cited work 10.1155/2022/3269692 · retracted 2023-10-11 · notice 10.1155/2023/9850459 · this paper published 2023-10-29
Rated major: it would touch a result — a value a result rests on, reported and recomputed p-values on opposite sides of the significance level, two passages that conflict with no sign which is right, or a cited work retracted before this paper was published.
In the paper
“Liu S. Sun Y. Luo N. Doppler Ultrasound Imaging Combined with Fetal Heart Detection in Predicting Fetal Distress in Pregnancy-Induced Hypertension under the Guidance of Artificial Intelligence Algorithm J. Healthc. Eng. 2021 2021 4405189 10.1155/2021/4405189 34659686 PMC8519722”
Cited work 10.1155/2021/4405189 · retracted 2023-10-11 · notice 10.1155/2023/9762610 · this paper published 2023-10-29
Rated major: it would touch a result — a value a result rests on, reported and recomputed p-values on opposite sides of the significance level, two passages that conflict with no sign which is right, or a cited work retracted before this paper was published.
In the paper
“The model of He et al. addressed the challenge of the identification and classification of intrauterine pregnancy residues that had the potential to reduce associated complications and improve surgical outcomes of curettages [167].”
Cited work 10.1155/2022/9937051 · retracted 2023-10-18 · notice 10.1155/2023/9780604 · this paper published 2023-10-29
A note, not an issue: for example, a cited work that was retracted only after this paper was published, which its authors could not have known.
In the paper
“These algorithms may improve medical diagnosis and potentially reduce clinical workload by replacing the sonographer’s manual tracing [168].”
Cited work 10.1155/2022/4010339 · retracted 2023-12-06 · notice 10.1155/2023/9792545 · this paper published 2023-10-29
A note, not an issue: for example, a cited work that was retracted only after this paper was published, which its authors could not have known.
In the paper
“Han, G., Jin, T., Zhang, L., Guo, C., Gui, H., Na, R., Wang, X., and Bai, H. (2022). Adoption of Compound Echocardiography under Artificial Intelligence Algorithm in Fetal Congenial Heart Disease Screening during Gestation. Appl. Bionics Biomech., 2022.”
Cited work 10.1155/2022/6410103 · retracted 2023-11-29 · notice 10.1155/2023/9814523 · this paper published 2023-10-29
A note, not an issue: for example, a cited work that was retracted only after this paper was published, which its authors could not have known.
In the paper
“Lastly, the studies of Burgos-Artizzu et al. and Sreelakshmy et al. portrayed AI methods for the estimation of GA through an analysis of transthalamic axial planes or cerebellum measurements [95,96].”
Cited work 10.1155/2022/8342767 · retracted 2023-12-29 · notice 10.1155/2023/9852080 · this paper published 2023-10-29
Citations
Cites
6 retracted
[Retracted] An Automated Deep Learning Model for the Cerebellum Segmentation from Fetal Brain Images
Sreelakshmy, R., Titus, A., Sasirekha, N., Logashanmugam, E., Begam, R. B., Ramkumar, G., & Raju, R. (2022) · BioMed Research International · doi:10.1155/2022/8342767 · Cited by 51 · cited 1×
“Lastly, the studies of Burgos-Artizzu et al. and Sreelakshmy et al. portrayed AI methods for the estimation of GA through an analysis of transthalamic axial planes or cerebellum measurements [95,96].”
MethodRetractedHan, G., Jin, T., Zhang, L., Guo, C., Gui, H., Na, R., Wang, X., & Bai, H. (2022) · Applied Bionics and Biomechanics · doi:10.1155/2022/6410103 · Cited by 23
RetractedLiu, S., Sun, Y., & Luo, N. (2021) · Journal of Healthcare Engineering · doi:10.1155/2021/4405189 · Cited by 11
RetractedWang, Q., Liu, D., & Liu, G. (2022) · Computational and Mathematical Methods in Medicine · doi:10.1155/2022/4010339 · Cited by 11 · cited 2×
“These algorithms may improve medical diagnosis and potentially reduce clinical workload by replacing the sonographer’s manual tracing [168].”
RetractedZhang, Y., Hou, J., Wang, Q., Hou, A., & Liu, Y. (2022) · Journal of Healthcare Engineering · doi:10.1155/2022/3269692 · Cited by 6
RetractedHe, H., Liu, R., Zhou, X., Zhang, Y., Yu, B., Xu, Z., & Huang, H. (2022) · Journal of Healthcare Engineering · doi:10.1155/2022/9937051 · Cited by 3 · cited 1×
“The model of He et al. addressed the challenge of the identification and classification of intrauterine pregnancy residues that had the potential to reduce associated complications and improve surgical outcomes of curettages [167].”
MethodRetractedSung, H., Ferlay, J., Siegel, R. L., Laversanne, M., Soerjomataram, I., Jemal, A., & Bray, F. (2021) · CA: A Cancer Journal for Clinicians · doi:10.3322/caac.21660 · Cited by 108,699 · cited 1×
“Breast cancer represents the most common malignancy in women worldwide and its incidence still shows a rising tendency [195].”
BackgroundThe PRISMA 2020 statement: An updated guideline for reporting systematic reviews
Page, M. J., McKenzie, J. E., Bossuyt, P. M., Boutron, I., Hoffmann, T. C., Mulrow, C. D., Shamseer, L., Tetzlaff, J. M., Akl, E. A., Brennan, S. E., et al. (2021) · BMJ · doi:10.1136/bmj.n71 · Cited by 108,283
Liberati, A., Altman, D. G., Tetzlaff, J., Mulrow, C., Gotzsche, P. C., Ioannidis, J. P. A., Clarke, M., Devereaux, P. J., Kleijnen, J., & Moher, D. (2009) · BMJ · doi:10.1136/bmj.b2700 · Cited by 17,648
Estimation of fetal weight with the use of head, body, and femur measurements—A prospective study
Hadlock, F. P., Harrist, R. B., Sharman, R. S., Deter, R. L., & Park, S. K. (1985) · American Journal of Obstetrics and Gynecology · doi:10.1016/0002-9378(85)90298-4 · Cited by 2,682 · cited 1×
“Biometric calculations are based on the acquisition of standard planes for measurements of fetal head circumference (HC), abdominal circumference (AC), and femur length [14].”
BackgroundSnijders, R., Noble, P., Sebire, N., Souka, A., & Nicolaides, K. (1998) · The Lancet · doi:10.1016/s0140-6736(97)11280-6 · Cited by 1,572 · cited 1×
“Combining clinical information (maternal age and serum parameters) with sonographic assessment of fetal characteristics, predominantly the assessment of nuchal translucency (NT), is recommended practice [131].”
BackgroundDonofrio, M. T., Moon-Grady, A. J., Hornberger, L. K., Copel, J. A., Sklansky, M. S., Abuhamad, A., Cuneo, B. F., Huhta, J. C., Jonas, R. A., Krishnan, A., et al. (2014) · Circulation · doi:10.1161/01.cir.0000437597.44550.5d · Cited by 1,275
Practice guidelines for performance of the routine mid-trimester fetal ultrasound scan
Salomon, L. J., Alfirevic, Z., Berghella, V., Bilardo, C., Hernandez‐Andrade, E., Johnsen, S. L., Kalache, K., Leung, K. ‐., Malinger, G., Munoz, H., et al. (2011) · Ultrasound in Obstetrics & Gynecology · doi:10.1002/uog.8831 · Cited by 1,006 · cited 1×
“The timing of the second trimester scan is standardized to 18 + 0 to 23 + 6 weeks of gestation and is intended for the evaluation of fetal growth and detection of fetal malformations [139].”
MethodPapageorghiou, A. T., Ohuma, E. O., Altman, D. G., Todros, T., Ismail, L. C., Lambert, A., Jaffer, Y. A., Bertino, E., Gravett, M. G., Purwar, M., et al. (2014) · The Lancet · doi:10.1016/s0140-6736(14)61490-2 · Cited by 870 · cited 1×
“Three of the included studies [78–80] used data collected in the Fetal Growth Longitudinal Study of the INTERGROWTH-21st Project, which aimed at developing international standards in fetal growth and size [81].”
ResultISUOG Practice Guidelines (updated): sonographic screening examination of the fetal heart
Carvalho, J., Allan, L., Chaoui, R., Copel, J., DeVore, G., Hecher, K., Lee, W., Munoz, H., Paladini, D., Tutschek, B., et al. (2013) · Ultrasound in Obstetrics & Gynecology · doi:10.1002/uog.12403 · Cited by 681
ISUOG Practice Guidelines: performance of first‐trimester fetal ultrasound scan
(2013) · Ultrasound in Obstetrics & Gynecology · doi:10.1002/uog.12342 · Cited by 621
Simple ultrasound-based rules for the diagnosis of ovarian cancer
Timmerman, D., Testa, A. C., Bourne, T., Ameye, L., Jurkovic, D., Van Holsbeke, C., Paladini, D., Van Calster, B., Vergote, I., Van Huffel, S., et al. (2008) · Ultrasound in Obstetrics & Gynecology · doi:10.1002/uog.5365 · Cited by 613 · cited 2×
“…examiners and thus the International Ovarian Tumor Analysis (IOTA) group has established US-based rules for classi fi cation of adnexal tumors [183]. even for experienced examiners and thus the International Ovarian Tumor Analysis (IOTA) group has established US-based rules classification of…”
BackgroundMaltepe, E., & Fisher, S. J. (2015) · Annual Review of Cell and Developmental Biology · doi:10.1146/annurev-cellbio-100814-125620 · Cited by 592 · cited 1×
“Little evidence exists on the neglected role of the placental characteristics and the prediction of these complications [106].”
Background(2007) · Ultrasound in Obstetrics & Gynecology · doi:10.1002/uog.3909 · Cited by 581 · cited 2×
“…head planes should be acquired following the international guideline of the International Society of Ultrasound in Obstetrics and Gynecology (ISUOG) [77], which enables the detection of key anatomical structures such as lateral ventricles, cavum septum pellucidum, cerebellum, and cisterna magna.”
BackgroundSonoNet: Real-Time Detection and Localisation of Fetal Standard Scan Planes in Freehand Ultrasound
Baumgartner, C. F., Kamnitsas, K., Matthew, J., Fletcher, T. P., Smith, S., Koch, L. M., Kainz, B., & Rueckert, D. (2017) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2017.2712367 · Cited by 416 · cited 4×
“Operator-related factors: US in general and obstetric US in particular, are known to require substantial experience and to be extremely training dependent [15].”
BackgroundMethodInfluentialStandard Plane Localization in Fetal Ultrasound via Domain Transferred Deep Neural Networks
Chen, H., Ni, D., Qin, J., Li, S., Yang, X., Wang, T., & Heng, P. A. (2015) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2015.2425041 · Cited by 379 · cited 4×
“Most studies reported the combined analysis of various standard planes (13 studies, [15,17,23–33]) or exclusively presented an algorithm for the analysis of HC (9 studies, [18,22,34–40]), AC (4 studies, [21,41–43]) or femur length (1 study, [44]).”
BackgroundMethodInfluentialGlobal guidelines for breast cancer screening: A systematic review
Ren, W., Chen, M., Qiao, Y., & Zhao, F. (2022) · The Breast · doi:10.1016/j.breast.2022.04.003 · Cited by 325 · cited 1×
“Especially in women with dense breast tissue, e.g., predominantly in young women or in Asian ethnicity, and for underserved areas, US diagnostics and screening are crucial [196].”
BackgroundArnaout, R., Curran, L., Zhao, Y., Levine, J. C., Chinn, E., & Moon-Grady, A. J. (2020) · doi:10.1101/2020.06.22.20137786 · Cited by 315 · cited 5×
“The combination of standard views allows for the detection of up to 90% of CHD; however, in clinical practice, the detection rate is only about 30% [48,50].”
BackgroundInfluentialAutomated measurement of fetal head circumference using 2D ultrasound images
van den Heuvel, T. L. A., de Bruijn, D., de Korte, C. L., & Ginneken, B. V. (2018) · PLOS ONE · doi:10.1371/journal.pone.0200412 · Cited by 280 · cited 1×
“Five studies used the freely available ‘HC18’ data set [45] for training and testing the algorithms, which contained 1334 2D images from 551 women of the standard fetal head plane [18,34,37,38,40].”
MethodThe placenta in fetal growth restriction: What is going wrong?
Sun, C., Groom, K. M., Oyston, C., Chamley, L. W., Clark, A. R., & James, J. L. (2020) · Placenta · doi:10.1016/j.placenta.2020.05.003 · Cited by 253 · cited 1×
“The placenta is known to play an important role in the pathogenesis of obstetric complications such as placenta previa, abnormally invasive placenta, fetal growth restriction, and hypertensive disorders of pregnancy [105].”
BackgroundEffect of Maternal Obesity on the Ultrasound Detection of Anomalous Fetuses
Dashe, J. S., McIntire, D. D., & Twickler, D. M. (2009) · Obstetrics & Gynecology · doi:10.1097/aog.0b013e3181a1d2f5 · Cited by 252 · cited 1×
“• Patient-related factors: Maternal obesity is known to have an impact on image quality and visualization of the fetus, and thus limits the accuracy of obstetric US examinations [19].”
BackgroundFUIQA: Fetal Ultrasound Image Quality Assessment with Deep Convolutional Networks
Wu, L., Cheng, J.-Z., Li, S., Lei, B., Wang, T., & Ni, D. (2017) · IEEE Transactions on Cybernetics · doi:10.1109/tcyb.2017.2671898 · Cited by 242 · cited 2×
“Wu et al. proposed a computerized quality assessment scheme for quality control of US images by identifying the ROI in fetal abdominal images [175].”
BackgroundIntroduction to artificial intelligence in ultrasound imaging in obstetrics and gynecology
Drukker, L., Noble, J. A., & Papageorghiou, A. T. (2020) · Ultrasound in Obstetrics & Gynecology · doi:10.1002/uog.22122 · Cited by 240
Burgos-Artizzu, X. P., Coronado-Gutiérrez, D., Valenzuela-Alcaraz, B., Bonet-Carne, E., Eixarch, E., Crispi, F., & Gratacós, E. (2020) · Scientific Reports · doi:10.1038/s41598-020-67076-5 · Cited by 240
Artificial intelligence in ultrasound
Shen, Y.-T., Chen, L., Yue, W.-W., & Xu, H.-X. (2021) · European Journal of Radiology · doi:10.1016/j.ejrad.2021.109717 · Cited by 214
Carneiro, G., Georgescu, B., Good, S., & Comaniciu, D. (2008) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2008.928917 · Cited by 205 · cited 2×
“The benefits of AI usage in standard plane acquisition were found to be the possibility of real-time applicability [15,25,32,33]; the incorporation of clinical aspects into image interpretation [21,23,26]; the feasibility of biometric assessment by non-experts [35,39,43]; the application of a…”
BackgroundResultIntra‐ and interobserver variability in fetal ultrasound measurements
Sarris, I., Ioannou, C., Chamberlain, P., Ohuma, E., Roseman, F., Hoch, L., Altman, D. G., Papageorghiou, A. T., & for the International Fetal and Newborn Growth Consortium for the 21 Century (INTERGROWTH‐21) (2012) · Ultrasound in Obstetrics & Gynecology · doi:10.1002/uog.10082 · Cited by 195
Evaluating reinforcement learning agents for anatomical landmark detection
Alansary, A., Oktay, O., Li, Y., Folgoc, L. L., Hou, B., Vaillant, G., Kamnitsas, K., Vlontzos, A., Glocker, B., Kainz, B., et al. (2019) · Medical Image Analysis · doi:10.1016/j.media.2019.02.007 · Cited by 185 · cited 1×
“The automated detection of brain structures and malformations was described by Lin et al. [85,86], Alansary et al. [87], and Gofer et al. [88] in 2D images and videos, and in 3D volumes by Hesse et al. and Huang et al. [79,89].”
MethodGao, Y., Zeng, S., Xu, X., Li, H., Yao, S., Song, K., Li, X., Chen, L., Tang, J., Xing, H., et al. (2022) · The Lancet Digital Health · doi:10.1016/s2589-7500(21)00278-8 · Cited by 185 · cited 4×
“The study by Gao et al. used a large, multicenter, and heterogenous data set, which disclosed that AI-enabled US outperformed an average trained radiologist in discriminat-J ing malignant and benign ovarian masses and improved the examiner’s accuracy [189].”
BackgroundInfluentialUsing deep-learning algorithms to classify fetal brain ultrasound images as normal or abnormal
Xie, H. N., Wang, N., He, M., Zhang, L. H., Cai, H. M., Xian, J. B., Lin, M. F., Zheng, J., & Yang, Y. Z. (2020) · Ultrasound in Obstetrics & Gynecology · doi:10.1002/uog.21967 · Cited by 176 · cited 5×
“Other study limitations were the missing training of AI algorithms with images of pathologies [79,86,95] and the problem of miscalculations when US images were not in accordance with the guidelines for standard planes [6,80].”
BackgroundMethodResultInfluentialUltrasound Standard Plane Detection Using a Composite Neural Network Framework
Chen, H., Wu, L., Dou, Q., Qin, J., Li, S., Cheng, J.-Z., Ni, D., & Heng, P.-A. (2017) · IEEE Transactions on Cybernetics · doi:10.1109/tcyb.2017.2685080 · Cited by 164 · cited 2×
“AI algorithms for the automated detection of various standard planes in US video scans have been reported by Płotka et al. [25], Chen et al. [28], and Baumgartner et al. [15].”
BackgroundMethodChristiansen, F., Epstein, E. L., Smedberg, E., Åkerlund, M., Smith, K., & Epstein, E. (2021) · Ultrasound in Obstetrics & Gynecology · doi:10.1002/uog.23530 · Cited by 142 · cited 4×
“…homogeneity of data due to a single examiner or single center study [188,192], a single investigated ethnicity [189], absent external validation [192,193], poor image quality [186,190], and, most importantly, small sample sizes not sufficient enough to train the algorithm [184,185,187,188,192,193].”
BackgroundResultInfluentialMulti-task learning for quality assessment of fetal head ultrasound images
Lin, Z., Li, S., Ni, D., Liao, Y., Wen, H., Du, J., Chen, S., Wang, T., & Lei, B. (2019) · Medical Image Analysis · doi:10.1016/j.media.2019.101548 · Cited by 129 · cited 1×
“The image quality assessment of whether a standard plane was correctly acquired, either by human operators or by automated extraction from 3D images, was effectively performed by models developed by the research groups of Lin et al. [90], Yaqub et al. [91], and Skelton et al. [92].”
MethodLi, J., Wang, Y., Lei, B., Cheng, J.-Z., Qin, J., Wang, T., Li, S., & Ni, D. (2018) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2017.2703890 · Cited by 120 · cited 2×
“The limitations of AI applications for fetal biometry were found to be reduced algo-rithm accuracy in poor quality images due to high maternal BMI [22,23], low contrast of anatomical structures [36], and higher GA with large fetuses [21].”
BackgroundMethodTowards automated semantic segmentation in prenatal volumetric ultrasound
Yang, X., Yu, L., Li, S., Wen, H., Luo, D., Bian, C., Qin, J., Ni, D., & Heng, P.-A. (2019) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2018.2858779 · Cited by 115 · cited 3×
“Tsai et al. aimed at facilitating the preliminary step for NT measurement, which was the automated detection of the correct mid-sagittal plane in 3D volumes [136], and Ryou et al. and Yang et al. proposed a model for the assessment of the whole fetus in 3D volumes [137,138].”
BackgroundZeng, Y., Tsui, P.-H., Wu, W., Zhou, Z., & Wu, S. (2021) · Journal of Digital Imaging · doi:10.1007/s10278-020-00410-5 · Cited by 113 · cited 6×
“…aspects into image interpretation [21,23,26]; the feasibility of biometric assessment by non-experts [35,39,43]; the application of a lightweight algorithm in point-of-care devices [18,34,37]; and, as a consequence of the latter two aspects, applicability for medically underserved areas [17,35].”
BackgroundMethodInfluentialYeo, L., & Romero, R. (2013) · Ultrasound in Obstetrics & Gynecology · doi:10.1002/uog.12563 · Cited by 110 · cited 3×
“Four of the included studies investigated the application of fetal intelligent navigation echocardiography (FINE) as a reliable technique that enabled the automated acquisition of nine standard echocardiographic views from specific 4D volumes of a single cardiac cycle in motion [51–54].”
BackgroundMethodDeep Learning Prediction of Ovarian Malignancy at US Compared with O-RADS and Expert Assessment
Chen, H., Yang, B.-W., Qian, L., Meng, Y.-S., Bai, X.-H., Hong, X.-W., He, X., Jiang, M.-J., Yuan, F., Du, Q.-W., et al. (2022) · Radiology · doi:10.1148/radiol.211367 · Cited by 110 · cited 5×
“These findings were consistent with other studies [185,186], but there were also studies with smaller sample sizes that showed a level of performance reaching those of human experts [188,191,192].”
BackgroundMethodResultInfluentialYu, Z., Tan, E.-L., Ni, D., Qin, J., Chen, S., Li, S., Lei, B., & Wang, T. (2018) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2017.2705031 · Cited by 109 · cited 1×
“Wang et al. and Yu et al. presented AI algorithms to automatically identify standard planes in 2D images [97,98].”
BackgroundLiu, Y., Zhang, Y., Cheng, R.-F., Liu, S., Qu, F., Yin, X., Wang, Q., Xiao, B., & Ye, Z. (2018) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.26192 · Cited by 108
Prenatal diagnosis of congenital heart disease
Gembruch, U. (1997) · Prenatal Diagnosis · doi:10.1002/(sici)1097-0223(199712)17:13<1283::aid-pd296>3.0.co;2-t · Cited by 107
Self-citationA Generic Quality Control Framework for Fetal Ultrasound Cardiac Four-Chamber Planes
Dong, J., Liu, S., Liao, Y., Wen, H., Lei, B., Li, S., & Wang, T. (2020) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2019.2948316 · Cited by 104 · cited 2×
“This issue was addressed by Dong et al. and Pietrolucci et al., who developed quality assessment AI models, of which one is already commercially available, known as ‘Heartassist™’ [70,71].”
MethodGong, Y., Zhang, Y., Zhu, H., Lv, J., Cheng, Q., Zhang, H., He, Y., & Wang, S. (2020) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2019.2946059 · Cited by 101
Amor, F., Vaccaro, H., Alcázar, J. L., León, M., Craig, J. M., & Martinez, J. (2009) · Journal of Ultrasound in Medicine · doi:10.7863/jum.2009.28.3.285 · Cited by 98 · cited 4×
“…homogeneity of data due to a single examiner or single center study [188,192], a single investigated ethnicity [189], absent external validation [192,193], poor image quality [186,190], and, most importantly, small sample sizes not sufficient enough to train the algorithm [184,185,187,188,192,193].”
BackgroundMethodInfluentialLearning-based prediction of gestational age from ultrasound images of the fetal brain
Namburete, A. I. L., Stebbing, R. V., Kemp, B., Yaqub, M., Papageorghiou, A. T., & Alison Noble, J. (2015) · Medical Image Analysis · doi:10.1016/j.media.2014.12.006 · Cited by 97 · cited 2×
“An important limitation of the AI models was described to be application in very early [144,147] or very late stages of pregnancy [146,147,152], the latter of which was due to the thickened texture of the fetal skull.”
BackgroundNamburete, A. I. L., Xie, W., Yaqub, M., Zisserman, A., & Noble, J. A. (2018) · Medical Image Analysis · doi:10.1016/j.media.2018.02.006 · Cited by 95 · cited 5×
“The establishment of a plane localization system as a 3D reference space for locating 2D planes was proposed by Yeung et [78,80,82,83].”
BackgroundMethodResultInfluentialDhombres, F., Bonnard, J., Bailly, K., Maurice, P., Papageorghiou, A. T., & Jouannic, J.-M. (2022) · Journal of Medical Internet Research · doi:10.2196/35465 · Cited by 93
van den Heuvel, T. L. A., Petros, H., Santini, S., de Korte, C. L., & van Ginneken, B. (2019) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2018.09.015 · Cited by 91 · cited 6×
“…aspects into image interpretation [21,23,26]; the feasibility of biometric assessment by non-experts [35,39,43]; the application of a lightweight algorithm in point-of-care devices [18,34,37]; and, as a consequence of the latter two aspects, applicability for medically underserved areas [17,35].”
BackgroundMethodInfluentialPremature Ovarian Failure Is Not Premature Menopause
Kalantaridou, S., & Nelson, L. M. (2000) · Annals of the New York Academy of Sciences · doi:10.1111/j.1749-6632.2000.tb06251.x · Cited by 90 · cited 1×
“Premature ovarian failure or insufficiency is defined by the interruption of ovarian function before the onset of menopause, affects around 1% in women aged 40, and can cause amenorrhea or infertility [227].”
BackgroundXu, L., Liu, M., Shen, Z., Wang, H., Liu, X., Wang, X., Wang, S., Li, T., Yu, S., Hou, M., et al. (2020) · Computerized Medical Imaging and Graphics · doi:10.1016/j.compmedimag.2019.101690 · Cited by 87 · cited 3×
“…presented a method specific to the interventricular septum [55]; Han et al. focused on the assessment of the left ventricle and left atrium [56]; and Xu et al. aimed at identifying seven anatomical structures, namely right and left atrium and ventricle, thorax, descending aorta, and epicardium [57].”
BackgroundMethodPlacental Volume at 11–13 Weeks’ Gestation in the Prediction of Birth Weight Percentile
Plasencia, W., Akolekar, R., Dagklis, T., Veduta, A., & Nicolaides, K. H. (2011) · Fetal Diagnosis and Therapy · doi:10.1159/000324318 · Cited by 86 · cited 1×
“It is known that early reduced placental volume is associated with small-for-gestational-age fetuses [111].”
BackgroundQuantitative ultrasound texture analysis of fetal lungs to predict neonatal respiratory morbidity
Bonet‐Carne, E., Palacio, M., Cobo, T., Perez‐Moreno, A., Lopez, M., Piraquive, J. P., Ramirez, J. C., Botet, F., Marques, F., & Gratacos, E. (2015) · Ultrasound in Obstetrics & Gynecology · doi:10.1002/uog.13441 · Cited by 85
Nurmaini, S., Rachmatullah, M. N., Sapitri, A. I., Darmawahyuni, A., Tutuko, B., Firdaus, F., Partan, R. U., & Bernolian, N. (2021) · Sensors · doi:10.3390/s21238007 · Cited by 81 · cited 1×
“Advantages are the facilitation of standard view acquisition [58,60] and CHD detection [53,61,62], as well as a significant reduction in examination time [52,55].”
BackgroundAI Estimation of Gestational Age from Blind Ultrasound Sweeps in Low-Resource Settings
Pokaprakarn, T., Prieto, J. C., Price, J. T., Kasaro, M. P., Sindano, N., Shah, H. R., Peterson, M., Akapelwa, M. M., Kapilya, F. M., Sebastião, Y. V., et al. (2022) · NEJM Evidence · doi:10.1056/evidoa2100058 · Cited by 80 · cited 3×
“The purpose of these studies, which were based on US data from the US and Zambia, was the successful establishment of an AI algorithm for GA estimation from simplified blind US sweeps of US novices in low-resource countries [144,145,152,153].”
BackgroundInfluentialVitale, S. G., Riemma, G., Haimovich, S., Carugno, J. A., Pacheco, L. A., Pérez‐Medina, T., Parry, J. P., Török, P., Tesařík, J., Corte, L. D., et al. (2022) · American Journal of Obstetrics and Gynecology · doi:10.1016/j.ajog.2022.07.043 · Cited by 80 · cited 1×
“In particular, endometrial thickness is known to show dynamics in premenopausal women throughout the menstrual cycle, while an increase in thickness in postmenopausal women represents a risk factor for the presence of malignancy [204].”
BackgroundDozen, A., Komatsu, M., Sakai, A., Komatsu, R., Shozu, K., Machino, H., Yasutomi, S., Arakaki, T., Asada, K., Kaneko, S., et al. (2020) · Biomolecules · doi:10.3390/biom10111526 · Cited by 79 · cited 3×
“Advantages are the facilitation of standard view acquisition [58,60] and CHD detection [53,61,62], as well as a significant reduction in examination time [52,55].”
BackgroundMethodAssessment of lung area in fetuses with congenital diaphragmatic hernia
Jani, J., Peralta, C. F. A., Benachi, A., Deprest, J., & Nicolaides, K. H. (2007) · Ultrasound in Obstetrics & Gynecology · doi:10.1002/uog.4051 · Cited by 76 · cited 1×
“…setting, the assessment of fetal lungs in terms of texture and volume can be relevant for prenatal diagnosis, risk classification, prediction of prognosis, and therapy planning in fetal congenital diaphragmatic hernia, profiting from the combination of the imaging modalities of US and MRI [228,232].”
BackgroundSridar, P., Kumar, A., Quinton, A., Nanan, R., Kim, J., & Krishnakumar, R. (2019) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2018.11.016 · Cited by 70
Martínez-Más, J., Bueno-Crespo, A., Khazendar, S., Remezal-Solano, M., Martínez-Cendán, J.-P., Jassim, S., Du, H., Al Assam, H., Bourne, T., & Timmerman, D. (2019) · PLOS ONE · doi:10.1371/journal.pone.0219388 · Cited by 70
Sakai, A., Komatsu, M., Komatsu, R., Matsuoka, R., Yasutomi, S., Dozen, A., Shozu, K., Arakaki, T., Machino, H., Asada, K., et al. (2022) · Biomedicines · doi:10.3390/biomedicines10030551 · Cited by 68
Yaqub, M., Kelly, B., Papageorghiou, A. T., & Noble, J. A. (2017) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2017.07.013 · Cited by 67
Jung, Y., Kim, T., Han, M.-R., Kim, S., Kim, G., Lee, S., & Choi, Y. J. (2022) · Scientific Reports · doi:10.1038/s41598-022-20653-2 · Cited by 67 · cited 2×
“…homogeneity of data due to a single examiner or single center study [188,192], a single investigated ethnicity [189], absent external validation [192,193], poor image quality [186,190], and, most importantly, small sample sizes not sufficient enough to train the algorithm [184,185,187,188,192,193].”
BackgroundHeremans, R., den Bosch, T. V., Valentin, L., Wynants, L., Pascual, M. A., Fruscio, R., Testa, A. C., Buonomo, F., Guerriero, S., Epstein, E., et al. (2022) · Ultrasound in Obstetrics and Gynecology · doi:10.1002/uog.24910 · Cited by 66 · cited 1×
“In gynecologic US examinations, evaluation of the endometrium is part of normal routine and obtains its significance due to the frequency of endometrial abnormalities, e.g., endometrial fibroids, polyps, endometrial hyperplasia or atrophy, and carcinoma [203].”
BackgroundStandard Plane Localization in Ultrasound by Radial Component Model and Selective Search
Ni, D., Yang, X., Chen, X., Chin, C.-T., Chen, S., Heng, P. A., Li, S., Qin, J., & Wang, T. (2014) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2014.06.006 · Cited by 65 · cited 2×
“Furthermore, real-time application is of particular importance in obstetric US and some authors noted the missing possibility for real-time application of various AI models, interestingly affecting especially those that are designed for intrapartum application [42,127,172–174].”
BackgroundMethodComputer-aided diagnosis for fetal brain ultrasound images using deep convolutional neural networks
Xie, B., Lei, T., Wang, N., Cai, H., Xian, J., He, M., Zhang, L., & Xie, H. (2020) · International Journal of Computer Assisted Radiology and Surgery · doi:10.1007/s11548-020-02182-3 · Cited by 65 · cited 1×
“Researchers Xie et al. [6,93] and Sahli et al. [94] reported a method for classifying US images into a binary system of ‘normal’ and ‘abnor-mal’ cases, in which Xie et al. additionally localized the structural lesions, which lead the algorithm to declare it ‘abnormal’ and thus recommend the…”
MethodLin, M., He, X., Guo, H., He, M., Zhang, L., Xian, J., Lei, T., Xu, Q., Zheng, J., Feng, J., et al. (2022) · Ultrasound in Obstetrics & Gynecology · doi:10.1002/uog.24843 · Cited by 65
Applications of Advanced Ultrasound Technology in Obstetrics
Leung, K. Y. (2021) · Diagnostics · doi:10.3390/diagnostics11071217 · Cited by 64 · cited 1×
“While 4D technology extends the 3D view of the scanned object with a time frame, enabling motion visualization, or so-called ‘real-time 3D’ [9], the term 5D is uncommonly used to describe AI-assisted US imaging including image enhancement processing or automated calculations [10,11].”
Automatic Estimation of Fetal Abdominal Circumference From Ultrasound Images
Jang, J., Park, Y., Kim, B., Lee, S. M., Kwon, J.-Y., & Seo, J. K. (2018) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2017.2776116 · Cited by 63 · cited 5×
“The limitations of AI applications for fetal biometry were found to be reduced algo-rithm accuracy in poor quality images due to high maternal BMI [22,23], low contrast of anatomical structures [36], and higher GA with large fetuses [21].”
BackgroundMethodInfluentialKim, B., Kim, K. C., Park, Y., Kwon, J.-Y., Jang, J., & Seo, J. K. (2018) · Physiological Measurement · doi:10.1088/1361-6579/aae255 · Cited by 62
Automatic quality assessment for 2D fetal sonographic standard plane based on multitask learning
Zhang, B., Liu, H., Luo, H., & Li, K. (2021) · Medicine · doi:10.1097/md.0000000000024427 · Cited by 61 · cited 1×
“Zhang et al. proposed an image quality assessment method for evaluating whether US images of standard planes fully show the anatomical structures with clear boundaries [29].”
MethodMoro, F., Albanese, M., Boldrini, L., Chiappa, V., Lenkowicz, J., Bertolina, F., Mascilini, F., Moroni, R., Gambacorta, M. A., Raspagliesi, F., et al. (2022) · Ultrasound in Obstetrics & Gynecology · doi:10.1002/uog.24805 · Cited by 61 · cited 5×
“Moro et al. aimed at establishing an AI model for risk stratification in endometrial cancer, but could not prove increased performance [209].”
BackgroundMethodInfluentialNurmaini, S., Partan, R. U., Bernolian, N., Sapitri, A. I., Tutuko, B., Rachmatullah, M. N., Darmawahyuni, A., Firdaus, F., & Mose, J. C. (2022) · Journal of Clinical Medicine · doi:10.3390/jcm11216454 · Cited by 61 · cited 1×
“Advantages are the facilitation of standard view acquisition [58,60] and CHD detection [53,61,62], as well as a significant reduction in examination time [52,55].”
BackgroundDrukker, L., Sharma, H., Droste, R., Alsharid, M., Chatelain, P., Noble, J. A., & Papageorghiou, A. T. (2021) · Scientific Reports · doi:10.1038/s41598-021-92829-1 · Cited by 59 · cited 3×
“To sum up, the included studies on this topic showed clinical benefits of AI in scan workflow through automating image labeling [154,157], enabling transfer learning for US novices [160], reducing clinician’s mental workload, and optimizing workflow [155].”
BackgroundMethodMachine learning for accurate estimation of fetal gestational age based on ultrasound images
Lee, L. H., Bradburn, E., Craik, R., Yaqub, M., Norris, S. A., Ismail, L. C., Ohuma, E. O., Barros, F. C., Lambert, A., Carvalho, M., et al. (2023) · npj Digital Medicine · doi:10.1038/s41746-023-00774-2 · Cited by 59 · cited 1×
“Dan et al. developed a DeepGA model that used the three main factors of fetal head, abdomen, and femur [149], while Lee et al. proposed a machine learning method to accurately estimate GA with standard US planes [150].”
MethodHsu, S.-T., Su, Y.-J., Hung, C.-H., Chen, M.-J., Lu, C.-H., & Kuo, C.-E. (2022) · BMC Medical Informatics and Decision Making · doi:10.1186/s12911-022-02047-6 · Cited by 58 · cited 6×
“These findings were consistent with other studies [185,186], but there were also studies with smaller sample sizes that showed a level of performance reaching those of human experts [188,191,192].”
BackgroundResultInfluentialAmbroise Grandjean, G., Hossu, G., Bertholdt, C., Noble, P., Morel, O., & Grangé, G. (2018) · Diagnostic and Interventional Imaging · doi:10.1016/j.diii.2018.08.001 · Cited by 57
Deep learning fetal ultrasound video model match human observers in biometric measurements
Płotka, S., Klasa, A., Lisowska, A., Seliga-Siwecka, J., Lipa, M., Trzciński, T., & Sitek, A. (2022) · Physics in Medicine & Biology · doi:10.1088/1361-6560/ac4d85 · Cited by 57 · cited 2×
“The benefits of AI usage in standard plane acquisition were found to be the possibility of real-time applicability [15,25,32,33]; the incorporation of clinical aspects into image interpretation [21,23,26]; the feasibility of biometric assessment by non-experts [35,39,43]; the application of a…”
BackgroundMethodSendra-Balcells, C., Campello, V. M., Torrents-Barrena, J., Ahmed, Y. A., Elattar, M., Ohene-Botwe, B., Nyangulu, P., Stones, W., Ammar, M., Benamer, L. N., et al. (2023) · Scientific Reports · doi:10.1038/s41598-023-29490-3 · Cited by 57
Automatic detection and measurement of nuchal translucency
Sciortino, G., Tegolo, D., & Valenti, C. (2017) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2017.01.008 · Cited by 55 · cited 3×
“Limitations could be uncovered when assessing fetal limbs due to its small anatomy and close surroundings [136–138], small data sets in rare anomalies [132,133], and missing real-time application for clinical applicability [133,134,138].”
BackgroundMethodLearning to map 2D ultrasound images into 3D space with minimal human annotation
Yeung, P.-H., Aliasi, M., Papageorghiou, A. T., Haak, M., Xie, W., & Namburete, A. I. L. (2021) · Medical Image Analysis · doi:10.1016/j.media.2021.101998 · Cited by 55 · cited 6×
“In obstetric US, AI models designed for automatic biometric measurements are usually restraint to a specific range of GA and can fail in images of different GA [34,40,78].”
BackgroundMethodResultInfluentialvan den Noort, F., van der Vaart, C. H., Grob, A. T. M., van de Waarsenburg, M. K., Slump, C. H., & van Stralen, M. (2019) · Ultrasound in Obstetrics & Gynecology · doi:10.1002/uog.20181 · Cited by 52
Weakly Supervised Estimation of Shadow Confidence Maps in Fetal Ultrasound Imaging
Meng, Q., Housden, J., Matthew, J., Rueckert, D., Schnabel, J. A., Kainz, B., Sinclair, M., Zimmer, V., Hou, B., Rajchl, M., et al. (2019) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2019.2913311 · Cited by 52
Sharma, H., Drukker, L., Chatelain, P., Droste, R., Papageorghiou, A. T., & Noble, J. A. (2021) · Medical Image Analysis · doi:10.1016/j.media.2021.101973 · Cited by 48
Aramendía-Vidaurreta, V., Cabeza, R., Villanueva, A., Navallas, J., & Alcázar, J. L. (2016) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2015.11.014 · Cited by 47
Li, P., Zhao, H., Liu, P., & Cao, F. (2020) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-020-02242-5 · Cited by 47
Gomes, R. G., Vwalika, B., Lee, C., Willis, A., Sieniek, M., Price, J. T., Chen, C., Kasaro, M. P., Taylor, J. A., Stringer, E. M., et al. (2022) · Communications Medicine · doi:10.1038/s43856-022-00194-5 · Cited by 47
Use of artificial intelligence in obstetrics: Not quite ready for prime time
Sarno, L., Neola, D., Carbone, L., Saccone, G., Carlea, A., Miceli, M., Iorio, G. G., Mappa, I., Rizzo, G., Girolamo, R. D., et al. (2023) · American Journal of Obstetrics & Gynecology MFM · doi:10.1016/j.ajogmf.2022.100792 · Cited by 47
Yang, T., Yuan, L., Li, P., & Liu, P. (2023) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2023.03.013 · Cited by 47 · cited 2×
“In total, 11 articles were summarized in this section, including the topics of endometriosis [216,217], premature ovarian failure [218,219], uterine fibroids [220,221], follicle tracking [222,223], and ectopic pregnancies [224,225].”
BackgroundVP-Nets : Efficient automatic localization of key brain structures in 3D fetal neurosonography
Huang, R., Xie, W., & Alison Noble, J. (2018) · Medical Image Analysis · doi:10.1016/j.media.2018.04.004 · Cited by 46
Accuracy of automated three-dimensional ultrasound imaging technique for fetal head biometry
Pluym, I. D., Afshar, Y., Holliman, K., Kwan, L., Bolagani, A., Mok, T., Silver, B., Ramirez, E., Han, C. S., & Platt, L. D. (2021) · Ultrasound in Obstetrics & Gynecology · doi:10.1002/uog.22171 · Cited by 46 · cited 5×
“Pluym et al. and Yang et al. analyzed 3D US volumes for the localization and measurement of various intracranial standard planes, such as the transventricular, transthalamic, or transcerebellar plane [23,24].”
BackgroundInfluentialAutomated 3D ultrasound image analysis for first trimester assessment of fetal health
Ryou, H., Yaqub, M., Cavallaro, A., Papageorghiou, A. T., & Alison Noble, J. (2019) · Physics in Medicine & Biology · doi:10.1088/1361-6560/ab3ad1 · Cited by 44
Subcortical segmentation of the fetal brain in 3D ultrasound using deep learning
Hesse, L. S., Aliasi, M., Moser, F., Haak, M. C., Xie, W., Jenkinson, M., & Namburete, A. I. L. (2022) · NeuroImage · doi:10.1016/j.neuroimage.2022.119117 · Cited by 44
Application of Deep Learning Model in the Sonographic Diagnosis of Uterine Adenomyosis
Raimondo, D., Raffone, A., Aru, A. C., Giorgi, M., Giaquinto, I., Spagnolo, E., Travaglino, A., Galatolo, F. A., Cimino, M. G. C. A., Lenzi, J., et al. (2023) · International Journal of Environmental Research and Public Health · doi:10.3390/ijerph20031724 · Cited by 44 · cited 3×
“In total, 11 articles were summarized in this section, including the topics of endometriosis [216,217], premature ovarian failure [218,219], uterine fibroids [220,221], follicle tracking [222,223], and ectopic pregnancies [224,225].”
BackgroundResultAutomated ultrasound assessment of amniotic fluid index using deep learning
Cho, H. C., Sun, S., Min Hyun, C., Kwon, J.-Y., Kim, B., Park, Y., & Seo, J. K. (2021) · Medical Image Analysis · doi:10.1016/j.media.2020.101951 · Cited by 43
Dong, F., She, R., Cui, C., Shi, S., Hu, X., Zeng, J., Wu, H., Xu, J., & Zhang, Y. (2021) · European Radiology · doi:10.1007/s00330-020-07561-7 · Cited by 43
Torrents-Barrena, J., Monill, N., Piella, G., Gratacós, E., Eixarch, E., Ceresa, M., & González Ballester, M. A. (2021) · Academic Radiology · doi:10.1016/j.acra.2019.11.006 · Cited by 42
Zhang, L., Dong, D., Sun, Y., Hu, C., Sun, C., Wu, Q., & Tian, J. (2022) · JAMA Network Open · doi:10.1001/jamanetworkopen.2022.17854 · Cited by 42 · cited 5×
“The potential benefits of these models were the highly accurate non-invasive method for anomaly screening [134] and reduced workload [133,135–137].”
BackgroundMethodInfluentialDevelopment of a Machine Learning Model for Sonographic Assessment of Gestational Age
Lee, C., Willis, A., Chen, C., Sieniek, M., Watters, A., Stetson, B., Uddin, A., Wong, J., Pilgrim, R., Chou, K., et al. (2023) · JAMA Network Open · doi:10.1001/jamanetworkopen.2022.48685 · Cited by 42 · cited 4×
“The purpose of these studies, which were based on US data from the US and Zambia, was the successful establishment of an AI algorithm for GA estimation from simplified blind US sweeps of US novices in low-resource countries [144,145,152,153].”
BackgroundInfluentialDeep learning to diagnose pouch of Douglas obliteration with ultrasound sliding sign
Maicas, G., Leonardi, M., Avery, J., Panuccio, C., Carneiro, G., Hull, M. L., & Condous, G. (2021) · Reproduction and Fertility · doi:10.1530/raf-21-0031 · Cited by 41 · cited 4×
“In total, 11 articles were summarized in this section, including the topics of endometriosis [216,217], premature ovarian failure [218,219], uterine fibroids [220,221], follicle tracking [222,223], and ectopic pregnancies [224,225].”
BackgroundMethodInfluentialExploring a new paradigm for the fetal anomaly ultrasound scan: Artificial intelligence in real time
Matthew, J., Skelton, E., Day, T. G., Zimmer, V. A., Gomez, A., Wheeler, G., Toussaint, N., Liu, T., Budd, S., Lloyd, K., et al. (2022) · Prenatal Diagnosis · doi:10.1002/pd.6059 · Cited by 41
Looney, P., Yin, Y., Collins, S. L., Nicolaides, K. H., Plasencia, W., Molloholli, M., Natsis, S., & Stevenson, G. N. (2021) · IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control · doi:10.1109/tuffc.2021.3052143 · Cited by 40 · cited 5×
“…sac as a predictor for early miscarriages in 2D images in pregnancies of 6–8 weeks of gestation [170], the research groups Sur et al. and Looney et al. proposed an 3D AI model to provide volumetric measurements of the embryo, placenta, gestational sac, yolk sac, and amniotic fluid [113,171].”
BackgroundMethodInfluentialArroyo, J., Marini, T. J., Saavedra, A. C., Toscano, M., Baran, T. M., Drennan, K., Dozier, A., Zhao, Y. T., Egoavil, M., Tamayo, L., et al. (2022) · PLOS ONE · doi:10.1371/journal.pone.0262107 · Cited by 40 · cited 3×
“…the incorporation of clinical aspects into image interpretation [21,23,26]; the feasibility of biometric assessment by non-experts [35,39,43]; the application of a lightweight algorithm in point-of-care devices [18,34,37]; and, as a consequence of the latter two aspects,…”
BackgroundMethodGupta, K., Balyan, K., Lamba, B., Puri, M., Sengupta, D., & Kumar, M. (2022) · The Journal of Maternal-Fetal & Neonatal Medicine · doi:10.1080/14767058.2021.1887847 · Cited by 39
Burgos-Artizzu, X. P., Coronado-Gutiérrez, D., Valenzuela-Alcaraz, B., Vellvé, K., Eixarch, E., Crispi, F., Bonet-Carne, E., Bennasar, M., & Gratacos, E. (2021) · American Journal of Obstetrics & Gynecology MFM · doi:10.1016/j.ajogmf.2021.100462 · Cited by 39
Model-Agnostic Method for Thoracic Wall Segmentation in Fetal Ultrasound Videos
Shozu, K., Komatsu, M., Sakai, A., Komatsu, R., Dozen, A., Machino, H., Yasutomi, S., Arakaki, T., Asada, K., Kaneko, S., et al. (2020) · Biomolecules · doi:10.3390/biom10121691 · Cited by 38 · cited 1×
“Furthermore, Meenakshi et al. focused on the identification of fetal kidneys [142] and Shozu et al. presented an AI model for the identification of the thoracic wall, which enabled plane detection for 4CV, but also allowed for the detection of thoracic malformations [143].”
BackgroundHuo, T., Li, L., Chen, X., Wang, Z., Zhang, X., Liu, S., Huang, J., Zhang, J., Yang, Q., Wu, W., et al. (2023) · Scientific Reports · doi:10.1038/s41598-022-26771-1 · Cited by 38
Endometrium segmentation on transvaginal ultrasound image using key-point discriminator
Park, H., Lee, H. J., Kim, H. G., Ro, Y. M., Shin, D., Lee, S. R., Kim, S. H., & Kong, M. (2019) · Medical Physics · doi:10.1002/mp.13677 · Cited by 37 · cited 3×
“Extracted limiting aspects for AI application were reduced accuracy in assessing endometria smaller than 3 mm [208], operator-dependence, limited data for algorithm training [205,206], and the need for human experts selecting images before analysis [205,207,209].”
BackgroundMethodMaraci, M. A., Yaqub, M., Craik, R., Beriwal, S., Self, A., von Dadelszen, P., Papageorghiou, A., & Noble, J. A. (2020) · Journal of medical imaging · doi:10.1117/1.jmi.7.1.014501 · Cited by 36 · cited 1×
“The recent topic of point-of-care-US was addressed in the research of Maraci et al., who successfully showed automated head plane detection and GA estimation with point-of-care devices [151].”
BackgroundDrukker, L., Sharma, H., Karim, J. N., Droste, R., Noble, J. A., & Papageorghiou, A. T. (2022) · Ultrasound in Obstetrics & Gynecology · doi:10.1002/uog.24975 · Cited by 36
Bai, J., Sun, Z., Yu, S., Lu, Y., Long, S., Wang, H., Qiu, R., Ou, Z., Zhou, M., Zhi, D., et al. (2022) · Frontiers in Physiology · doi:10.3389/fphys.2022.940150 · Cited by 36 · cited 2×
“In addition to this, Lu et al. and Bai et al. proposed a method for the automated measurement of the angle of progression, which allowed for the estimation of fetal head descent by identifying the symphysis and fetal head contour [173,174].”
BackgroundMethodToward AI-supported US Triage of Women with Palpable Breast Lumps in a Low-Resource Setting
Berg, W. A., López Aldrete, A.-L., Jairaj, A., Ledesma Parea, J. C., García, C. Y., McClennan, R. C., Cen, S. Y., Larsen, L. H., de Lara, M. T. S., & Love, S. (2023) · Radiology · doi:10.1148/radiol.223351 · Cited by 36 · cited 3×
“Berg et al. pointed out the importance of training for sonographers to obtain a reasonable image quality for AI analysis [197], while Huang et al. compared handheld US to robotically performed AI-assisted US and showed reduced costs, shorter examination times, and a higher detection rate in the…”
BackgroundMethodAlzubaidi, M., Agus, M., Shah, U., Makhlouf, M., Alyafei, K., & Househ, M. (2022) · Diagnostics · doi:10.3390/diagnostics12092229 · Cited by 35 · cited 3×
“The benefits of the GA AI models were the possibility for application in low-resource countries [144,145,148,149,152], even without internet connectivity [145], and in portable devices [148], promising high accuracy with an error of 3.9 to 5 days in GA estimation [149,152].”
BackgroundInfluentialRecognition of facial expression of fetuses by artificial intelligence (AI)
Miyagi, Y., Hata, T., Bouno, S., Koyanagi, A., & Miyake, T. (2021) · Journal of Perinatal Medicine · doi:10.1515/jpm-2020-0537 · Cited by 34
Fetal face as important indicator of fetal brain function
AboEllail, M. A. M., & Hata, T. (2017) · Journal of Perinatal Medicine · doi:10.1515/jpm-2016-0377 · Cited by 33 · cited 1×
“Facial expressions such as eye blinking, mouthing, smiling, and yawning have been described to indicate fetal brain maturation, in utero stress may result in scowling, while the meaning of tongue expulsion and neutral expression remain unclear [101,102].”
BackgroundMaurice, P., Dhombres, F., Blondiaux, E., Friszer, S., Guilbaud, L., Lelong, N., Khoshnood, B., Charlet, J., Perrot, N., Jauniaux, E., et al. (2017) · Journal of Gynecology Obstetrics and Human Reproduction · doi:10.1016/j.jogoh.2017.03.004 · Cited by 33 · cited 3×
“In total, 11 articles were summarized in this section, including the topics of endometriosis [216,217], premature ovarian failure [218,219], uterine fibroids [220,221], follicle tracking [222,223], and ectopic pregnancies [224,225].”
BackgroundZhu, F., Liu, M., Wang, F., Qiu, D., Li, R., & Dai, C. (2021) · Mathematical Biosciences & Engineering · doi:10.3934/mbe.2021387 · Cited by 33 · cited 2×
“Most studies reported the combined analysis of various standard planes (13 studies, [15,17,23–33]) or exclusively presented an algorithm for the analysis of HC (9 studies, [18,22,34–40]), AC (4 studies, [21,41–43]) or femur length (1 study, [44]).”
BackgroundYin, P., & Wang, H. (2022) · Computational and Mathematical Methods in Medicine · doi:10.1155/2022/1786994 · Cited by 33
Lin, Q., Zhou, Y., Shi, S., Zhang, Y., Yin, S., Liu, X., Peng, Q., Huang, S., Jiang, Y., Chen, C., et al. (2022) · Computer Methods and Programs in Biomedicine · doi:10.1016/j.cmpb.2022.107170 · Cited by 33
Agent with Warm Start and Adaptive Dynamic Termination for Plane Localization in 3D Ultrasound
Yang, X., Dou, H., Huang, R., Xue, W., Huang, Y., Qian, J., Zhang, Y., Luo, H., Guo, H., Wang, T., et al. (2021) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2021.3069663 · Cited by 32 · cited 2×
“Pluym et al. and Yang et al. analyzed 3D US volumes for the localization and measurement of various intracranial standard planes, such as the transventricular, transthalamic, or transcerebellar plane [23,24].”
BackgroundGhi, T., Conversano, F., Ramirez Zegarra, R., Pisani, P., Dall'Asta, A., Lanzone, A., Lau, W., Vimercati, A., Iliescu, D. G., Mappa, I., et al. (2022) · Ultrasound in Obstetrics & Gynecology · doi:10.1002/uog.23739 · Cited by 32
Qiao, S., Pan, S., Luo, G., Pang, S., Chen, T., Singh, A. K., & Lv, Z. (2023) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2022.3143319 · Cited by 32 · cited 2×
“Lastly, two included studies developed AI models for model improvement itself by synthesizing high-quality 4CV images for model training [67] and by providing existing models with new input data and supporting learning process [68].”
BackgroundMethodDeep Learning Strategies for Ultrasound in Pregnancy
Diniz, P. H. B., Yin, Y., & Collins, S. (2020) · EMJ Reproductive Health · doi:10.33590/emjreprohealth/20-00100 · Cited by 32 · cited 3×
“In particular, the subspecialty of obstetrics is profoundly dependent on the diagnostic imaging tool of US because of its non-invasive, cost-effective, real-time, and low-radiation characteristics for fetal scanning [3,4].”
BackgroundArtificial intelligence in perinatal diagnosis and management of congenital heart disease
Reddy, C. D., Van den Eynde, J., & Kutty, S. (2022) · Seminars in Perinatology · doi:10.1016/j.semperi.2022.151588 · Cited by 32
A hierarchical model for automatic nuchal translucency detection from ultrasound images
Deng, Y., Wang, Y., Chen, P., & Yu, J. (2012) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2012.04.002 · Cited by 31 · cited 2×
“The research groups Walker et al. [132], Zhang et al. [133], Sciortino et al. [134], and Deng et al. [135] addressed the time consuming process of NT measurement by introducing AI models for its automated detection and measurement, in particular for the diagnosis of trisomy 21 [133] or cystic…”
MethodNeonatal management and outcomes of prenatally diagnosed CHDs
Bensemlali, M., Bajolle, F., Laux, D., Parisot, P., Ladouceur, M., Fermont, L., Lévy, M., Le Bidois, J., Raimondi, F., Ville, Y., et al. (2017) · Cardiology in the Young · doi:10.1017/s1047951116000639 · Cited by 31 · cited 1×
“It allows for appropriate counseling for parents, as well as delivery and treatment planning, and, in some cases, even in utero therapy [49].”
BackgroundGembicki, M., Hartge, D. R., Dracopoulos, C., & Weichert, J. (2020) · Journal of Ultrasound in Medicine · doi:10.1002/jum.15105 · Cited by 31 · cited 2×
“Advantages are the facilitation of standard view acquisition [58,60] and CHD detection [53,61,62], as well as a significant reduction in examination time [52,55].”
BackgroundNero, C., Ciccarone, F., Boldrini, L., Lenkowicz, J., Paris, I., Capoluongo, E. D., Testa, A. C., Fagotti, A., Valentini, V., & Scambia, G. (2020) · Scientific Reports · doi:10.1038/s41598-020-73505-2 · Cited by 31 · cited 3×
“…studies assessed the performance of automated tumor classification [184,191,192], one study developed a population-based screening method for BRCA mutations [193], and one study focused on the automated elimination of artefacts and objects in US images to increase the accuracy of the AI model [194].”
BackgroundMethodAl-karawi, D., Al-Assam, H., Du, H., Sayasneh, A., Landolfo, C., Timmerman, D., Bourne, T., & Jassim, S. (2021) · Ultrasonic Imaging · doi:10.1177/0161734621998091 · Cited by 31
Zeng, W., Luo, J., Cheng, J., & Lu, Y. (2022) · Medical Physics · doi:10.1002/mp.15700 · Cited by 31
Walker, M. C., Willner, I., Miguel, O. X., Murphy, M. S. Q., El-Chaâr, D., Moretti, F., Dingwall Harvey, A. L. J., Rennicks White, R., Muldoon, K. A., Carrington, A. M., et al. (2022) · PLOS ONE · doi:10.1371/journal.pone.0269323 · Cited by 31
Feature-based fuzzy connectedness segmentation of ultrasound images with an object completion step
Rueda, S., Knight, C. L., Papageorghiou, A. T., & Alison Noble, J. (2015) · Medical Image Analysis · doi:10.1016/j.media.2015.07.002 · Cited by 30 · cited 1×
“Further, Rueda et al. aimed at investigating the fetal nutritional status using AI-assisted assessment of the adipose and fat-free tissue of the fetal arm in US images [181].”
Multitask Deep Neural Network for the Fully Automatic Measurement of the Angle of Progression
Lu, Y., Zhi, D., Zhou, M., Lai, F., Chen, G., Ou, Z., Zeng, R., Long, S., Qiu, R., Zhou, M., et al. (2022) · Computational and Mathematical Methods in Medicine · doi:10.1155/2022/5192338 · Cited by 30 · cited 1×
“In addition to this, Lu et al. and Bai et al. proposed a method for the automated measurement of the angle of progression, which allowed for the estimation of fetal head descent by identifying the symphysis and fetal head contour [173,174].”
MethodDu, Y., Fang, Z., Jiao, J., Xi, G., Zhu, C., Ren, Y., Guo, Y., & Wang, Y. (2021) · Ultrasound in Obstetrics & Gynecology · doi:10.1002/uog.22037 · Cited by 29 · cited 2×
“Du et al. proposed an AI model to classify the lung textures in pregnancies affected by gestational diabetes or preeclampsia [162], while Xia et al. and Chen et al. developed a lung maturation grading model that can be implemented for identifying abnormal development and evaluating the…”
BackgroundMethodPfob, A., Sidey-Gibbons, C., Barr, R. G., Duda, V., Alwafai, Z., Balleyguier, C., Clevert, D.-A., Fastner, S., Gomez, C., Goncalo, M., et al. (2022) · European Radiology · doi:10.1007/s00330-021-08519-z · Cited by 29 · cited 1×
“Limitations to AI usage in breast US were the missing clinical context in unimodal approaches only focusing on image analysis [202], small data sets for algorithm training, and a lower accuracy in borderline findings [201].”
BackgroundDiscriminative Learning for Automatic Staging of Placental Maturity via Multi-layer Fisher Vector
Lei, B., Yao, Y., Chen, S., Li, S., Li, W., Ni, D., & Wang, T. (2015) · Scientific Reports · doi:10.1038/srep12818 · Cited by 28 · cited 1×
“The automated classification of placental maturity was proposed by Lei et al. and Li et al. [116,117].”
BackgroundHierarchical Class Incremental Learning of Anatomical Structures in Fetal Echocardiography Videos
Patra, A., & Noble, J. A. (2020) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2020.2973372 · Cited by 28 · cited 1×
“Lastly, two included studies developed AI models for model improvement itself by synthesizing high-quality 4CV images for model training [67] and by providing existing models with new input data and supporting learning process [68].”
BackgroundAndreasen, L. A., Feragen, A., Christensen, A. N., Thybo, J. K., Svendsen, M. B. S., Zepf, K., Lekadir, K., & Tolsgaard, M. G. (2023) · Scientific Reports · doi:10.1038/s41598-023-29105-x · Cited by 28 · cited 2×
“Andreasen et al. and Schilpzand et al. presented an effective AI algorithm for placental localization, including heterogenous data through differences in sonographers’ expertise [109], or using a previous established sweep protocol in low-resource settings [110].”
Yang, Y., Wu, B., Wu, H., Xu, W., Lyu, G., Liu, P., & He, S. (2023) · Journal of Perinatal Medicine · doi:10.1515/jpm-2023-0041 · Cited by 28
Graupner, O., Enzensberger, C., Wieg, L., Willruth, A., Steinhard, J., Gembruch, U., Doelle, A., Bahlmann, F., Kawecki, A., Degenhardt, J., et al. (2016) · Ultrasound in Obstetrics and Gynecology · doi:10.1002/uog.14940 · Cited by 27 · cited 1×
“Not only the detection of structural abnormalities in case of CHD, but also cardiac function analysis, is a future topic of AI applications in fetal echocardiography using tissue Doppler US, which can be relevant, e.g., for fetuses diagnosed with hypoplastic left heart syndrome [74–76].”
Self-citationCurrent status of fetal neurodevelopmental assessment: Four‐dimensional ultrasound study
Hata, T. (2016) · Journal of obstetrics and gynaecology research · doi:10.1111/jog.13099 · Cited by 27 · cited 1×
“Additionally, fetal movements and facial expressions were found to be correlated with fetal brain activity and development state [100].”
BackgroundHu, R., Singla, R., Yan, R., Mayer, C., & Rohling, R. N. (2019) · 2019 41st Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2019.8857448 · Cited by 27 · cited 2×
“…sonographic placental assessment is mainly restricted to the identification of placental location, adhesion, or insertion site of umbilical cord [108], and further assessment is limited due to the impossibility to detect minimal change in texture by routine scan and time-consuming examinations.”
BackgroundMachine Learning Algorithms for Classification of First‐Trimester Fetal Brain Ultrasound Images
Gofer, S., Haik, O., Bardin, R., Gilboa, Y., & Perlman, S. (2022) · Journal of Ultrasound in Medicine · doi:10.1002/jum.15860 · Cited by 27
Pfob, A., Sidey-Gibbons, C., Barr, R. G., Duda, V., Alwafai, Z., Balleyguier, C., Clevert, D.-A., Fastner, S., Gomez, C., Goncalo, M., et al. (2022) · European Journal of Cancer · doi:10.1016/j.ejca.2022.09.018 · Cited by 27 · cited 2×
“The possibility of avoiding unnecessary breast biopsies was the result of two further studies, of which one used an AI-assisted multi-modal shear wave elastography model [199,200].”
BackgroundResultImproving the Segmentation Accuracy of Ovarian-Tumor Ultrasound Images Using Image Inpainting
Chen, L., Qiao, C., Wu, M., Cai, L., Yin, C., Yang, M., Sang, X., & Bai, W. (2023) · Bioengineering · doi:10.3390/bioengineering10020184 · Cited by 27 · cited 1×
“…studies assessed the performance of automated tumor classification [184,191,192], one study developed a population-based screening method for BRCA mutations [193], and one study focused on the automated elimination of artefacts and objects in US images to increase the accuracy of the AI model [194].”
MethodFetal MRI radiomics: non-invasive and reproducible quantification of human lung maturity
Prayer, F., Watzenböck, M. L., Heidinger, B. H., Rainer, J., Schmidbauer, V. U., Prosch, H., Ulm, B., Rubesova, E., Prayer, D., & Kasprian, G. J. (2023) · European Radiology · doi:10.1007/s00330-022-09367-1 · Cited by 26
Torrents-Barrena, J., López-Velazco, R., Piella, G., Masoller, N., Valenzuela-Alcaraz, B., Gratacós, E., Eixarch, E., Ceresa, M., & Ángel González Ballester, M. (2019) · Computer Methods and Programs in Biomedicine · doi:10.1016/j.cmpb.2019.104993 · Cited by 25
van den Noort, F., Manzini, C., van der Vaart, C. H., van Limbeek, M. A. J., Slump, C. H., & Grob, A. T. M. (2022) · Ultrasound in Obstetrics & Gynecology · doi:10.1002/uog.24810 · Cited by 25
Alsharid, M., Cai, Y., Sharma, H., Drukker, L., Papageorghiou, A. T., & Noble, J. A. (2022) · Medical Image Analysis · doi:10.1016/j.media.2022.102630 · Cited by 25 · cited 2×
“Lastly, Alsharid et al. developed a novel video captioning model for the description of second-trimester US scans by training an AI model with speech recordings and gaze-tracking information of sonographers while performing US scans [159].”
BackgroundDeepGA for automatically estimating fetal gestational age through ultrasound imaging
Dan, T., Chen, X., He, M., Guo, H., He, X., Chen, J., Xian, J., Hu, Y., Zhang, B., Wang, N., et al. (2023) · Artificial Intelligence in Medicine · doi:10.1016/j.artmed.2022.102453 · Cited by 25 · cited 2×
“The benefits of the GA AI models were the possibility for application in low-resource countries [144,145,148,149,152], even without internet connectivity [145], and in portable devices [148], promising high accuracy with an error of 3.9 to 5 days in GA estimation [149,152].”
BackgroundMethodInfluentialAutomatic Fetal Measurements in Ultrasound Using Constrained Probabilistic Boosting Tree
Carneiro, G., Georgescu, B., Good, S., & Comaniciu, D. (2007) · Springer eBooks · doi:10.1007/978-3-540-75759-7_69 · Cited by 24
Ma, M., Li, Y., Chen, R., Huang, C., Mao, Y., & Zhao, B. (2020) · The International Journal of Cardiovascular Imaging · doi:10.1007/s10554-020-01932-3 · Cited by 24 · cited 2×
“Advantages are the facilitation of standard view acquisition [58,60] and CHD detection [53,61,62], as well as a significant reduction in examination time [52,55].”
BackgroundMethodXia, T.-H., Tan, M., Li, J.-H., Wang, J.-J., Wu, Q.-Q., & Kong, D.-X. (2021) · Chinese Medical Journal · doi:10.1097/cm9.0000000000001547 · Cited by 24 · cited 3×
“…textures in pregnancies affected by gestational diabetes or preeclampsia [162], while Xia et al. and Chen et al. developed a lung maturation grading model that can be implemented for identifying abnormal development and evaluating the effectiveness of antenatal corticosteroid therapy [161,163].”
BackgroundRizzo, G., Aiello, E., Elena Pietrolucci, M., & Arduini, D. (2016) · The Journal of Maternal-Fetal & Neonatal Medicine · doi:10.3109/14767058.2015.1081891 · Cited by 23 · cited 1×
“While 4D technology extends the 3D view of the scanned object with a time frame, enabling motion visualization, or so-called ‘real-time 3D’ [9], the term 5D is uncommonly used to describe AI-assisted US imaging including image enhancement processing or automated calculations [10,11].”
Beksaç, M. S., Başaran, F., Eskiizmirliler, S., Erkmen, A. M., & Yörükan, S. (1996) · European Journal of Obstetrics & Gynecology and Reproductive Biology · doi:10.1016/0301-2115(95)02256-2 · Cited by 23
Recognition of Fetal Facial Ultrasound Standard Plane Based on Texture Feature Fusion
Wang, X., Liu, Z., Du, Y., Diao, Y., Liu, P., Lv, G., & Zhang, H. (2021) · Computational and Mathematical Methods in Medicine · doi:10.1155/2021/6656942 · Cited by 23 · cited 2×
“Fetal facial malformations, such as cleft lip and palate, can be assessed by acquiring standard planes such as the ocular axial, median sagittal, and nasolabial coronal plane [97].”
BackgroundSchilpzand, M., Neff, C., van Dillen, J., van Ginneken, B., Heskes, T., de Korte, C., & van den Heuvel, T. (2022) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2021.12.006 · Cited by 23
Automatic Measurement of Endometrial Thickness From Transvaginal Ultrasound Images
Liu, Y., Zhou, Q., Peng, B., Jiang, J., Fang, L., Weng, W., Wang, W., Wang, S., & Zhu, X. (2022) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2022.853845 · Cited by 23 · cited 4×
“Extracted limiting aspects for AI application were reduced accuracy in assessing endometria smaller than 3 mm [208], operator-dependence, limited data for algorithm training [205,206], and the need for human experts selecting images before analysis [205,207,209].”
BackgroundMethodInfluentialAutomated quantitative evaluation of fetal atrioventricular annular plane systolic excursion
Herling, L., Johnson, J., Ferm‐Widlund, K., Zamprakou, A., Westgren, M., & Acharya, G. (2021) · Ultrasound in Obstetrics & Gynecology · doi:10.1002/uog.23703 · Cited by 22 · cited 1×
“…Herling et al. analyzed the automated measurement of fetal atrioventricular plane displacement in US videos of cardiac cycles using color tissue Doppler [65], and Scharf et al. evaluated the automated assessment of the myocardial performance index as a tool to analyze fetal cardiac function [66].”
MethodSahli, H., Mouelhi, A., Ben Slama, A., Sayadi, M., & Rachdi, R. (2019) · Journal of Medical Engineering & Technology · doi:10.1080/03091902.2019.1653389 · Cited by 21
Prieto, J. C., Shah, H., Rosenbaum, A., Jiang, X., Musonda, P., Price, J., Stringer, E. M., Vwalika, B., Stamilio, D., & Stringer, J. (2021) · Medical Imaging 2021: Image Processing · doi:10.1117/12.2582243 · Cited by 21 · cited 1×
“The purpose of these studies, which were based on US data from the US and Zambia, was the successful establishment of an AI algorithm for GA estimation from simplified blind US sweeps of US novices in low-resource countries [144,145,152,153].”
BackgroundZhang, J., Petitjean, C., & Ainouz, S. (2022) · Journal of Imaging · doi:10.3390/jimaging8020023 · Cited by 21 · cited 2×
“Five studies used the freely available ‘HC18’ data set [45] for training and testing the algorithms, which contained 1334 2D images from 551 women of the standard fetal head plane [18,34,37,38,40].”
MethodWatzenboeck, M. L., Heidinger, B. H., Rainer, J., Schmidbauer, V., Ulm, B., Rubesova, E., Prayer, D., Kasprian, G., & Prayer, F. (2023) · Insights into Imaging · doi:10.1186/s13244-023-01376-y · Cited by 21 · cited 2×
“…setting, the assessment of fetal lungs in terms of texture and volume can be relevant for prenatal diagnosis, risk classification, prediction of prognosis, and therapy planning in fetal congenital diaphragmatic hernia, profiting from the combination of the imaging modalities of US and MRI [228,232].”
BackgroundWang, X., Bao, N., Xin, X., Tan, J., Li, H., Zhou, S., & Liu, H. (2022) · Quantitative Imaging in Medicine and Surgery · doi:10.21037/qims-21-1155 · Cited by 20 · cited 3×
“Extracted limiting aspects for AI application were reduced accuracy in assessing endometria smaller than 3 mm [208], operator-dependence, limited data for algorithm training [205,206], and the need for human experts selecting images before analysis [205,207,209].”
BackgroundWu, H., Wu, B., Lai, F., Liu, P., Lyu, G., He, S., & Dai, J. (2023) · Computational and Mathematical Methods in Medicine · doi:10.1155/2023/5650378 · Cited by 20
AI: Can It Make a Difference to the Predictive Value of Ultrasound Breast Biopsy?
Browne, J. L., Pascual, M. Á., Perez, J., Salazar, S., Valero, B., Rodriguez, I., Cassina, D., Alcázar, J. L., Guerriero, S., & Graupera, B. (2023) · Diagnostics · doi:10.3390/diagnostics13040811 · Cited by 20
Pietrolucci, M. E., Maqina, P., Mappa, I., Marra, M. C., Antonio, F. D., & Rizzo, G. (2023) · Journal of Perinatal Medicine · doi:10.1515/jpm-2023-0052 · Cited by 20
Automatic Extraction of Hiatal Dimensions in 3-D Transperineal Pelvic Ultrasound Recordings
Williams, H., Cattani, L., Van Schoubroeck, D., Yaqub, M., Sudre, C., Vercauteren, T., D'Hooge, J., & Deprest, J. (2021) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2021.08.009 · Cited by 19 · cited 4×
“Two studies used 3D US images [211,212], two 2D [213–215], two of them derived 2D images from a 3D/4D data set [214,215], and one did not specify the type of image [210].”
BackgroundMethodInfluentialWang, Y., Zhang, Q., Yin, C., Chen, L., Yang, Z., Jia, S., Sun, X., Bai, Y., Han, F., & Yuan, Z. (2022) · BMC Pregnancy and Childbirth · doi:10.1186/s12884-022-04936-0 · Cited by 19 · cited 2×
“…analyzed an automated assessment of the gestational sac as a predictor for early miscarriages in 2D images in pregnancies of 6–8 weeks of gestation [170], the research groups Sur et al. and Looney et al. proposed an 3D AI model to provide volumetric measurements of the embryo, placenta,…”
MethodSur, S. D., Jayaprakasan, K., Jones, N. W., Clewes, J., Winter, B., Cash, N., Campbell, B., & Raine-Fenning, N. J. (2010) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2010.03.006 · Cited by 18 · cited 2×
“The potential benefits of these models were the development of fetal volume nomograms for precise fetal growth assessment [171] and the establishment of an early screening method for the prediction of adverse pregnancy outcomes [113], which facilitates adequate consultancy and recommendation for…”
Gupta, L., Sisodia, R. S., Pallavi, V., Firtion, C., & Ramachandran, G. (2011) · 2011 Annual International Conference of the IEEE Engineering in Medicine and Biology Society · doi:10.1109/iembs.2011.6091824 · Cited by 18 · cited 1×
“…et al. established a model for the classification of shadow-rich and shadow-free regions in various US images [176] and Gupta et al. presented an algorithm for a better separation between the fetus and surrounding information in fetal US, such as maternal tissue, placenta, or amniotic fluid [177].”
BackgroundAutomatic Fetal Middle Sagittal Plane Detection in Ultrasound Using Generative Adversarial Network
Tsai, P.-Y., Hung, C.-H., Chen, C.-Y., & Sun, Y.-N. (2020) · Diagnostics · doi:10.3390/diagnostics11010021 · Cited by 18 · cited 2×
“Tsai et al. aimed at facilitating the preliminary step for NT measurement, which was the automated detection of the correct mid-sagittal plane in 3D volumes [136], and Ryou et al. and Yang et al. proposed a model for the assessment of the whole fetus in 3D volumes [137,138].”
BackgroundVisual-Assisted Probe Movement Guidance for Obstetric Ultrasound Scanning Using Landmark Retrieval
Zhao, C., Droste, R., Drukker, L., Papageorghiou, A. T., & Noble, J. A. (2021) · Lecture notes in computer science · doi:10.1007/978-3-030-87237-3_64 · Cited by 18
Weakly Supervised Learning of Placental Ultrasound Images with Residual Networks
Qi, H., Collins, S., & Noble, A. (2017) · Communications in computer and information science · doi:10.1007/978-3-319-60964-5_9 · Cited by 17
Deep learning-based plane pose regression in obstetric ultrasound
Di Vece, C., Dromey, B., Vasconcelos, F., David, A. L., Peebles, D., & Stoyanov, D. (2022) · International Journal of Computer Assisted Radiology and Surgery · doi:10.1007/s11548-022-02609-z · Cited by 17
Wang, X., Yang, T., Zhang, Y., Liu, X., Zhang, Y., Sun, L., Gu, X., Chen, Z., Guo, Y., Xue, C., et al. (2022) · Prenatal Diagnosis · doi:10.1002/pd.6220 · Cited by 17
Szentimrey, Z., Ameri, G., Hong, C. X., Cheung, R. Y. K., Ukwatta, E., & Eltahawi, A. (2023) · Medical Physics · doi:10.1002/mp.16389 · Cited by 17
Rahman, R., Alam, M. G. R., Reza, M. T., Huq, A., Jeon, G., Uddin, M. Z., & Hassan, M. M. (2023) · Ultrasonics · doi:10.1016/j.ultras.2023.107017 · Cited by 17 · cited 1×
“In comparison with the analysis of 2D US videos, Sridar et al. [26], Burgos-Artizzu et al. [27], Rahman et al. [30], and Carneiro et al. [31,32] reported AI systems for the automated detection or measurement of various standard planes in 2D US images.”
ResultAutomatic Lacunae Localization in Placental Ultrasound Images via Layer Aggregation
Qi, H., Collins, S., & Noble, J. A. (2018) · Lecture Notes in Computer Science · doi:10.1007/978-3-030-00934-2_102 · Cited by 16
Malhotra, N., Noor, N., Vignarajan, C., & Vanamail, P. (2020) · Journal of Human Reproductive Sciences · doi:10.4103/jhrs.jhrs_91_20 · Cited by 16 · cited 3×
“In total, 11 articles were summarized in this section, including the topics of endometriosis [216,217], premature ovarian failure [218,219], uterine fibroids [220,221], follicle tracking [222,223], and ectopic pregnancies [224,225].”
BackgroundKaplan, E., Ekinci, T., Kaplan, S., Barua, P. D., Dogan, S., Tuncer, T., Tan, R.-S., Arunkumar, N., & Acharya, U. R. (2022) · Contrast Media & Molecular Imaging · doi:10.1155/2022/6034971 · Cited by 16
Yang, C., Yang, Z., Liao, S., Guo, J., Yin, S., Liu, C., & Kang, Y. (2022) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2022.105801 · Cited by 16 · cited 3×
“…aspects into image interpretation [21,23,26]; the feasibility of biometric assessment by non-experts [35,39,43]; the application of a lightweight algorithm in point-of-care devices [18,34,37]; and, as a consequence of the latter two aspects, applicability for medically underserved areas [17,35].”
BackgroundMethodComputer-assisted navigation applied to fetal cardiac intervention
Emery, S. P., Kreutzer, J., Sherman, F. R., Fujimoto, K. L., Jaramaz, B., Nikou, C., Tobita, K., & Keller, B. B. (2007) · The International Journal of Medical Robotics and Computer Assisted Surgery · doi:10.1002/rcs.145 · Cited by 15 · cited 2×
“In case of the study of Emery et al., an AI-based navigation system for needle tracking in fetal aortic valvuloplasty promised increased safety, reduced intervention time, and transferability for other fetal interventions such as amniocentesis [69].”
BackgroundAutomated region mask for four-chamber fetal heart biometry
Vijayalakshmi, S., Sriraam, N., Suresh, S., & Muttan, S. (2013) · Journal of Clinical Monitoring and Computing · doi:10.1007/s10877-012-9404-7 · Cited by 15 · cited 2×
“As a solution to this issue and an emerging research focus, the detection of the fetal heart as a ROI in US images can be performed by AI models [72,73].”
BackgroundMeenakshi, S., Suganthi, M., & Sureshkumar, P. (2019) · Journal of Medical Systems · doi:10.1007/s10916-019-1324-3 · Cited by 15 · cited 1×
“Furthermore, Meenakshi et al. focused on the identification of fetal kidneys [142] and Shozu et al. presented an AI model for the identification of the thoracic wall, which enabled plane detection for 4CV, but also allowed for the detection of thoracic malformations [143].”
BackgroundChen, P., Chen, Y., Deng, Y., Wang, Y., He, P., Lv, X., & Yu, J. (2020) · International Journal of Computer Assisted Radiology and Surgery · doi:10.1007/s11548-020-02211-1 · Cited by 15 · cited 3×
“…AI model performance in 2D and 3D US imaging can be limited due to imaging artefacts and noise, especially when automated tissue analysis is intended, for example, for fetal lung assessment, whereas the method of MRI for this specific application seems future-oriented and promising [127,163].”
BackgroundSharma, H., Drukker, L., Papageorghiou, A. T., & Noble, J. A. (2021) · 2021 IEEE 18th International Symposium on Biomedical Imaging (ISBI) · doi:10.1109/isbi48211.2021.9433863 · Cited by 15 · cited 2×
“It can support US novices in skill training and enables non-experts the acquisition of US images [160], e.g., for telehealth approaches in times of shortage of expert sonographers [50].”
BackgroundDevelopment and validation of a composite AI model for the diagnosis of levator ani muscle avulsion
Wu, S., Ren, Y., Lin, X., Huang, Z., Zheng, Z., & Zhang, X. (2022) · European Radiology · doi:10.1007/s00330-022-08754-y · Cited by 15 · cited 1×
“Two studies used 3D US images [211,212], two 2D [213–215], two of them derived 2D images from a 3D/4D data set [214,215], and one did not specify the type of image [210].”
MethodMiyagi, Y., Hata, T., Bouno, S., Koyanagi, A., & Miyake, T. (2023) · International Journal of Gynecology & Obstetrics · doi:10.1002/ijgo.14569 · Cited by 15
Zhao, X., Liu, M., Wu, S., Zhang, B., Burjoo, A., Yang, Y., & Xu, D. (2023) · Quantitative Imaging in Medicine and Surgery · doi:10.21037/qims-22-965 · Cited by 15
Scharf, J. L., Dracopoulos, C., Gembicki, M., Welp, A., & Weichert, J. (2023) · Diagnostics · doi:10.3390/diagnostics13101705 · Cited by 15
Developing a knowledge base to support the annotation of ultrasound images of ectopic pregnancy
Dhombres, F., Maurice, P., Friszer, S., Guilbaud, L., Lelong, N., Khoshnood, B., Charlet, J., Perrot, N., Jauniaux, E., Jurkovic, D., et al. (2017) · Journal of Biomedical Semantics · doi:10.1186/s13326-017-0117-1 · Cited by 14 · cited 2×
“In total, 11 articles were summarized in this section, including the topics of endometriosis [216,217], premature ovarian failure [218,219], uterine fibroids [220,221], follicle tracking [222,223], and ectopic pregnancies [224,225].”
BackgroundTunable image quality control of 3-D ultrasound using switchable CycleGAN
Huh, J., Khan, S., Choi, S., Shin, D., Lee, J. E., Lee, E. S., & Ye, J. C. (2023) · Medical Image Analysis · doi:10.1016/j.media.2022.102651 · Cited by 14 · cited 1×
“Another study addressed the issue of poor image quality in 3D US images due to data processing and showed that AI image enhancement methods could produce increased 3D image quality with user-preferential flexibility in both gynecological and obstetric US images [226].”
BackgroundTang, J., Han, J., Xie, B., Xue, J., Zhou, H., Jiang, Y., Hu, L., Chen, C., Zhang, K., Zhu, F., et al. (2023) · International Journal of Environmental Research and Public Health · doi:10.3390/ijerph20032377 · Cited by 13 · cited 1×
“…as facial malformations can be a phenotype of an underlying genetic disorder, Tang et al. used 3D images of fetal faces to develop a novel approach for the early, non-invasive identification of genetic disorders by analyzing key facial regions, such as the jaw, frontal bone, and nasal bone [99].”
BackgroundAutomatic staging of placental maturity based on dense descriptor
Li, X., Yao, Y., Ni, D., Chen, S., Li, S., Lei, B., & Wang, T. (2014) · Bio-Medical Materials and Engineering · doi:10.3233/bme-141100 · Cited by 12 · cited 1×
“The automated classification of placental maturity was proposed by Lei et al. and Li et al. [116,117].”
BackgroundSun, L., Wang, J., Su, X., Chen, X., Zhou, Y., Zhang, X., Lu, H. S., Niu, J., Yu, L., Sun, C., et al. (2021) · BMJ Open · doi:10.1136/bmjopen-2021-049640 · Cited by 12
Cited by
Guillen-Grima, F., Guillen-Aguinaga, S., Guillen-Aguinaga, L., Alas-Brun, R., Onambele, L., Ortega, W., Montejo, R., Aguinaga-Ontoso, E., Barach, P., & Aguinaga-Ontoso, I. (2023) · Clinics and Practice · doi:10.3390/clinpract13060130 · Cited by 72
Progress in the Application of Artificial Intelligence in Ultrasound-Assisted Medical Diagnosis
Li, Y., Li, Q., Fu, K., Zhou, X., & Zhang, K. (2025) · Bioengineering · doi:10.3390/bioengineering12030288 · Cited by 85
“This evolution is effectively dismantling traditional limitations in ultrasound examinations, improving imaging quality, optimizing procedural workflows, and advancing the field of ultrasound medicine toward precision healthcare.”
Stringer, J. S. A., Pokaprakarn, T., Prieto, J. C., Vwalika, B., Chari, S. V., Sindano, N., Freeman, B. L., Sikapande, B., Davis, N. M., Sebastião, Y. V., et al. (2024) · JAMA · doi:10.1001/jama.2024.10770 · Cited by 70
Brandão, M., Mendes, F., Martins, M., Cardoso, P., Macedo, G., Mascarenhas, T., & Mascarenhas, M. (2024) · Journal of Clinical Medicine · doi:10.3390/jcm13041061 · Cited by 48
“Nevertheless, there is a need to understand the limitations of the available clinical imaging methods, namely clinician workload and intra and interobserver variability, and AI has the potential to overcome these limitations while increasing diagnostic accuracy [23].”
BackgroundQuality of ChatGPT-Generated Therapy Recommendations for Breast Cancer Treatment in Gynecology
Stalp, J. L., Denecke, A., Jentschke, M., Hillemanns, P., & Klapdor, R. (2024) · Current Oncology · doi:10.3390/curroncol31070284 · Cited by 27
“Since this research is often lacking clinical applicability [2], these systems are not implemented in daily medical treatment routines, therapy recommendations or patient care in Germany.”
BackgroundMethod
Metadata
- Authors
- Jost, E., Kosian, P., Jimenez Cruz, J., Albarqouni, S., Gembruch, U., Strizek, B., & Recker, F.
- Affiliations
- University Hospital Bonn (DE)
- Department of Obstetrics and Gynecology, University Hospital Bonn, Venusberg Campus 1, 53127 Bonn, Germany
- Corresponding author
- Recker, Florian
- ORCID
- Venue
- Journal of Clinical Medicine
- Publisher
- MDPI AG
- Published
- 2023-10-29
- Volume
- 12
- Issue
- 21
- Pages
- 6833
- ISSN
- 2077-0383 (ISSN-L)
- PMC
- PMC10649694
- OpenAlex
- W4388105557
- Cited by
- 44
- References
- 246
- Citations by year
- 2026: 7 · 2025: 16 · 2024: 20 · 2023: 1
- FWCI
- 0.52
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Licence
- Locations
- Journal of Clinical Medicine (publishedVersion, cc-by)
- PubMed Central (publishedVersion, cc-by-nc-sa)
- PubMed (publishedVersion)
- bonndoc (University of Bonn) (submittedVersion, cc-by)
- PuSH - Publication Server of Helmholtz Zentrum München (submittedVersion)
- Funders
- Open Access Publication Fund of the University of Bonn
- Topics
- Health Sciences › Medicine › Health Informatics › Artificial Intelligence in Healthcare and Education
- Health Sciences › Medicine › Critical Care and Intensive Care Medicine › Ultrasound in Clinical Applications
- Physical Sciences › Computer Science › Artificial Intelligence › AI in cancer detection
- Keywords
- artificial intelligence, ultrasonography, obstetrics, gynecology, anatomical measurements, pathology detection, fetal biometry, echocardiography, neurosonography, adnexal mass, breast mass, endometrial assessment, pelvic floor assessment
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
The claim verdicts this report counts are experimental: their accuracy is not yet measured.
A language model drew the claims from the paper on 2026-10-10, under version 3 of the claim definition (model deepseek-v4.1-flash, prompt extract-v3).
A second model labelled each claim on 2026-10-10 (model jev-1.13-20260917, definition revision gold-guideline-v0.2).
Cited sources are checked with a language model’s help (gpt-6-sol).
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.