CoChat

The DOI matches its Crossref record; 43 of the 44 references it cites were found in a registry or an index; 21 of the 41 sources its claims cite were checked for support.

Diagnostic Yield and Clinical Implications of Implantable Loop Recorders in Patients with Syncope in Germany: A National Database Analysis

Open access
Mueller-Leisse, Johanna, Hillmann, Henrike Aenne Katrin, Iserloh, Laura, Fruehauf, Bjoern, Duncker, David · 2024 · Journal of Clinical Medicine

Abstract

In patients with unexplained syncope, implantable loop recorders (ILR) are used to detect arrhythmias as a cause of syncope. This study aimed to assess the diagnostic yield and clinical implications arising from ILR implantation in patients with syncope in Germany. Secondary longitudinal data were obtained from a large German research database including anonymized data from nationwide statutory health insurances, representative for the German population. Patients ≥ 18 years with a diagnosis of syncope and ILR implantation between 2017 and 2018 were analyzed, and cardiac diagnoses and therapies during a follow-up period of two years assessed. Of 2,403,301 continuously insured persons in 2017-2018, 1360 (0.1%) received an ILR and 675 patients (45.6% female) were included. During follow-up, arrhythmias were diagnosed in 65.0%. The following antiarrhythmic therapies were established: pacemaker and defibrillator implantations in 20% and 1.5%, respectively, ablation therapy in 3.0%, and antiarrhythmic drug therapy in 4.7%. Aside from the diagnoses typically associated with syncope, atrial fibrillation or flutter was diagnosed in 37.0%, and anticoagulation therapy was initiated in 21.5%. There was a high diagnostic yield of arrhythmias following ILR implantation, leading to a relevant number of syncope-specific treatment. Arrhythmias not necessarily related to syncope were also diagnosed, leading to a high rate of anticoagulation therapy.

Overview

CoChat Summary

## TL;DR

This retrospective national database study found that implantable loop recorders (ILRs) in German patients with syncope had a high two-year diagnostic yield, with arrhythmias detected in 65.0% of patients. The findings also showed substantial downstream treatment changes, including pacemaker implantation in 20.0% and initiation of anticoagulation in 21.5%.

## Key findings

  • Of 2,403,301 continuously insured persons, 1,360 (0.06% in the results text; 0.1% in the abstract) received an ILR in 2017–2018, and 675 patients with syncope were included in the analysis.
  • During 2 years of follow-up, arrhythmias were diagnosed in 65.0% of patients; 37.0% were diagnosed with atrial fibrillation or flutter.
  • 23.6% underwent at least one interventional therapy: 20.0% received a pacemaker, 1.5% a defibrillator, and 3.0% ablation therapy.
  • 24.7% started drug therapy: 21.5% were started on anticoagulation and 4.7% on antiarrhythmic medication.

## Methods

  • Observational retrospective longitudinal secondary-data analysis using the WIG2 research database of anonymized German statutory health insurance claims; the database is described as representative for the German population by age and gender.
  • Included adults ≥18 years with syncope (ICD-10-GM R55) and ILR implantation (OPS 5-377.8) between 2017 and 2018, with continuous insurance for 24 months after the index day; excluded patients with prior stroke, ablation, prior ILR-related procedures, or cardiac electronic devices in 2016.
  • Main analyses were descriptive: counts, percentages, mean, and SD; outcomes included ILR-related cardiac diagnoses, time to diagnosis, and initiation/time to therapies identified via ICD-10-GM, OPS, and ATC codes.

## Limitations

  • The paper states that billing-based ICD-10-GM/OPS coding may have led to over- and under-diagnosis, and that grouped ICD-10-GM codes did not allow detailed diagnostic analysis.
  • The paper states that R55 includes syncope and collapse, which may have included some patients without actual syncope, though it argues this was likely limited because reimbursement requires evidence of indication beyond ICD coding.
  • The paper states that there were no detailed data on pre-ILR diagnostic workup and only 2 years of follow-up, with no further follow-up beyond certain therapies, so other relevant findings may have been missed.

Model-written summary. Check it against the paper before relying on it.

Integrity signals

Registry

Crossref · 10.3390/jcm13061564

Cites

43 of 43 references verified0 citation errors · 0 not checkable

Statistics

Nothing to recompute.

Figures

Figure 1 Study population. WIG2, research database of the German Scientific Institute for Health Economics and Health System Research; ILR, implantable loop recorder.
Figure 1 Study population. WIG2, research database of the German Scientific Institute for Health Economics and Health System Research; ILR, implantable loop recorder.CC BY · PubMed Central

Verification

Claims the paper makes

9 Valid · 0 Not valid · 5 Not checked · 33 Own results and interpretations

26 more claims

Create a free account to see all 47 claims and to verify the 3 references still open.

See all claims — free account
  • Probably not a substantial claim. 10
  • It may state two separate claims as one. 6
  • The quote only partly states this claim. 1

Create a free account to see these claims.

Citations

Cites

Cited by

See all 5

Metadata

Authors
Mueller-Leisse, J., Hillmann, H. A. K., Iserloh, L., Fruehauf, B., & Duncker, D.
Affiliations
  • Hannover Heart Rhythm Center, Department of Cardiology and Angiology, Hannover Medical School, 30625 Hannover, Germany
  • Medizinische Hochschule Hannover (DE)
  • Medtronic (Germany) (DE)
Corresponding author
Duncker, David
Venue
Journal of Clinical Medicine
Publisher
MDPI AG
Published
2024-03-08
Volume
13
Issue
6
Pages
1564
ISSN
2077-0383 (ISSN-L)
OpenAlex
W4392601270
Cited by
4
References
44
Citations by year
2026: 2 · 2025: 1 · 2024: 1
FWCI
1.12
Type
journal article
Language
en
Open access
Locations
  • Journal of Clinical Medicine (publishedVersion, cc-by)
  • PubMed Central (publishedVersion, cc-by)
  • PubMed (publishedVersion)
Funders
Medtronic
Topics
  • Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiovascular Syncope and Autonomic Disorders
  • Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiac electrophysiology and arrhythmias
  • Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiac pacing and defibrillation studies
Keywords
implantable loop recorder, syncope, arrhythmia detection, diagnostic yield, antiarrhythmic therapy, pacemaker implantation, defibrillator implantation, ablation therapy, atrial fibrillation, anticoagulation, unexplained syncope

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

The claim verdicts this report counts are experimental: their accuracy is not yet measured.

A language model drew the claims from the paper on 2026-10-10, under version 3 of the claim definition (model deepseek-v4.1-flash, prompt extract-v3).

A second model labelled each claim on 2026-10-10 (model jev-1.13-20260917, definition revision gold-guideline-v0.2).

Cited sources are checked with a language model’s help (gpt-6-sol).

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.