The DOI matches its Crossref record; 102 of the 102 references it cites were found in a registry or an index.
Properties and Applications of PDMS for Biomedical Engineering: A Review
Open accessAbstract
Polydimethylsiloxane (PDMS) is an elastomer with excellent optical, electrical and mechanical properties, which makes it well-suited for several engineering applications. Due to its biocompatibility, PDMS is widely used for biomedical purposes. This widespread use has also led to the massification of the soft-lithography technique, introduced for facilitating the rapid prototyping of micro and nanostructures using elastomeric materials, most notably PDMS. This technique has allowed advances in microfluidic, electronic and biomedical fields. In this review, an overview of the properties of PDMS and some of its commonly used treatments, aiming at the suitability to those fields’ needs, are presented. Applications such as microchips in the biomedical field, replication of cardiovascular flow and medical implants are also reviewed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Xia, Y., & Whitesides, G. M. (1998) · Angewandte Chemie International Edition · doi:10.1002/(sici)1521-3773(19980316)37:5<550::aid-anie550>3.0.co;2-g · Cited by 4,285
Solvent Compatibility of Poly(dimethylsiloxane)-Based Microfluidic Devices
Lee, J. N., Park, C., & Whitesides, G. M. (2003) · Analytical Chemistry · doi:10.1021/ac0346712 · Cited by 2,643
Mechanical characterization of bulk Sylgard 184 for microfluidics and microengineering
Johnston, I. D., McCluskey, D. K., Tan, C. K. L., & Tracey, M. C. (2014) · Journal of Micromechanics and Microengineering · doi:10.1088/0960-1317/24/3/035017 · Cited by 1,495
Characterization of Polydimethylsiloxane (PDMS) Properties for Biomedical Micro/Nanosystems
Mata, A., Fleischman, A. J., & Roy, S. (2005) · Biomedical Microdevices · doi:10.1007/s10544-005-6070-2 · Cited by 1,318
PDMS absorption of small molecules and consequences in microfluidic applications
Toepke, M. W., & Beebe, D. J. (2006) · Lab on a Chip · doi:10.1039/b612140c · Cited by 1,190
Gas sorption, diffusion, and permeation in poly(dimethylsiloxane)
Merkel, T. C., Bondar, V. I., Nagai, K., Freeman, B. D., & Pinnau, I. (2000) · Journal of Polymer Science Part B: Polymer Physics · doi:10.1002/(sici)1099-0488(20000201)38:3<415::aid-polb8>3.0.co;2-z · Cited by 1,178
Recent developments in PDMS surface modification for microfluidic devices
Zhou, J., Ellis, A. V., & Voelcker, N. H. (2010) · ELECTROPHORESIS · doi:10.1002/elps.200900475 · Cited by 857
PDMS with designer functionalities—Properties, modifications strategies, and applications
Wolf, M. P., Salieb-Beugelaar, G. B., & Hunziker, P. (2018) · Progress in Polymer Science · doi:10.1016/j.progpolymsci.2018.06.001 · Cited by 853
Engineers are from PDMS-land, Biologists are from Polystyrenia
Berthier, E., Young, E. W. K., & Beebe, D. (2012) · Lab on a Chip · doi:10.1039/c2lc20982a · Cited by 799
Microfabrication meets microbiology
Weibel, D. B., DiLuzio, W. R., & Whitesides, G. M. (2007) · Nature Reviews Microbiology · doi:10.1038/nrmicro1616 · Cited by 788
Bodas, D., & Khan-Malek, C. (2007) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2006.08.037 · Cited by 600
Surface modification of poly(dimethylsiloxane) microchannels
Makamba, H., Kim, J. H., Lim, K., Park, N., & Hahn, J. H. (2003) · ELECTROPHORESIS · doi:10.1002/elps.200305627 · Cited by 551
Merkel, T. J., Jones, S. W., Herlihy, K. P., Kersey, F. R., Shields, A. R., Napier, M., Luft, J. C., Wu, H., Zamboni, W. C., Wang, A. Z., et al. (2011) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1010013108 · Cited by 548
PDMS-based microfluidic devices for biomedical applications
Fujii, T. (2002) · Microelectronic Engineering · doi:10.1016/s0167-9317(02)00494-x · Cited by 518
Hassler, C., Boretius, T., & Stieglitz, T. (2011) · Journal of Polymer Science Part B: Polymer Physics · doi:10.1002/polb.22169 · Cited by 501
PDMS microfluidics: A mini review
Raj M, K., & Chakraborty, S. (2020) · Journal of Applied Polymer Science · doi:10.1002/app.48958 · Cited by 481
On the aging of oxygen plasma-treated polydimethylsiloxane surfaces
Morra, M., Occhiello, E., Marola, R., Garbassi, F., Humphrey, P., & Johnson, D. (1990) · Journal of Colloid and Interface Science · doi:10.1016/0021-9797(90)90038-p · Cited by 477
Trantidou, T., Elani, Y., Parsons, E., & Ces, O. (2017) · Microsystems & Nanoengineering · doi:10.1038/micronano.2016.91 · Cited by 450
(1997) · Springer eBooks · doi:10.1007/978-94-011-5342-3 · Cited by 442
Oxygen plasma treatment for reducing hydrophobicity of a sealed polydimethylsiloxane microchannel
Tan, S. H., Nguyen, N.-T., Chua, Y. C., & Kang, T. G. (2010) · Biomicrofluidics · doi:10.1063/1.3466882 · Cited by 440
X-ray photoelectron spectroscopy: Progress and perspectives
Fadley, C. S. (2010) · Journal of Electron Spectroscopy and Related Phenomena · doi:10.1016/j.elspec.2010.01.006 · Cited by 440
Polydimethylsiloxane Composites Characterization and Its Applications: A Review
Ariati, R., Sales, F., Souza, A., Lima, R. A., & Ribeiro, J. (2021) · Polymers · doi:10.3390/polym13234258 · Cited by 440
Self-citationMechanical properties of silicones for MEMS
Schneider, F., Fellner, T., Wilde, J., & Wallrabe, U. (2008) · Journal of Micromechanics and Microengineering · doi:10.1088/0960-1317/18/6/065008 · Cited by 435
Shelby, J. P., White, J., Ganesan, K., Rathod, P. K., & Chiu, D. T. (2003) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.2433968100 · Cited by 433
Hydrophobicity recovery of polydimethylsiloxane after exposure to corona discharges
Hillborg, H., & Gedde, U. W. (1998) · Polymer · doi:10.1016/s0032-3861(97)00484-9 · Cited by 430
International Critical Tables of Numerical Data, Physics, Chemistry and Technology
GRIFFITHS, E. (1927) · Nature · doi:10.1038/119735a0 · Cited by 425
Characterization of topographical effects on macrophage behavior in a foreign body response model
Chen, S., Jones, J. A., Xu, Y., Low, H.-Y., Anderson, J. M., & Leong, K. W. (2010) · Biomaterials · doi:10.1016/j.biomaterials.2010.01.074 · Cited by 389
Re-configurable fluid circuits by PDMS elastomer micromachining
Armani, D., Liu, C., & Aluru, N. (1999) · Technical Digest. IEEE International MEMS 99 Conference. Twelfth IEEE International Conference on Micro Electro Mechanical Systems (Cat. No.99CH36291) · doi:10.1109/memsys.1999.746817 · Cited by 382
Sterilization techniques for biodegradable scaffolds in tissue engineering applications
Dai, Z., Ronholm, J., Tian, Y., Sethi, B., & Cao, X. (2016) · Journal of Tissue Engineering · doi:10.1177/2041731416648810 · Cited by 355
Surface modification for PDMS‐based microfluidic devices
Zhou, J., Khodakov, D. A., Ellis, A. V., & Voelcker, N. H. (2012) · ELECTROPHORESIS · doi:10.1002/elps.201100482 · Cited by 344
Biomedical microfluidic devices by using low-cost fabrication techniques: A review
Faustino, V., Catarino, S. O., Lima, R., & Minas, G. (2016) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2015.11.031 · Cited by 338
Self-citationDeformability study of breast cancer cells using microfluidics
Hou, H. W., Li, Q. S., Lee, G. Y. H., Kumar, A. P., Ong, C. N., & Lim, C. T. (2009) · Biomedical Microdevices · doi:10.1007/s10544-008-9262-8 · Cited by 322
UV/ozone modification of poly(dimethylsiloxane) microfluidic channels
Berdichevsky, Y., Khandurina, J., Guttman, A., & Lo, Y.-H. (2004) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2003.09.022 · Cited by 318
Shakeri, A., Khan, S., & Didar, T. F. (2021) · Lab on a Chip · doi:10.1039/d1lc00288k · Cited by 312
Khanafer, K., Duprey, A., Schlicht, M., & Berguer, R. (2009) · Biomedical Microdevices · doi:10.1007/s10544-008-9256-6 · Cited by 273
Gökaltun, A., Kang, Y. B., Yarmush, M. L., Usta, O. B., & Asatekin, A. (2019) · Scientific Reports · doi:10.1038/s41598-019-43625-5 · Cited by 269
Micro Electromechanical Systems (MEMS) Based Microfluidic Devices for Biomedical Applications
Ashraf, M. W., Tayyaba, S., & Afzulpurkar, N. (2011) · International Journal of Molecular Sciences · doi:10.3390/ijms12063648 · Cited by 263
Boyce, M. C., & Arruda, E. M. (1990) · Polymer Engineering & Science · doi:10.1002/pen.760302005 · Cited by 253
Müller, A., Wapler, M. C., & Wallrabe, U. (2019) · Soft Matter · doi:10.1039/c8sm02105h · Cited by 239
Sterilization of implantable polymer-based medical devices: A review
Tipnis, N. P., & Burgess, D. J. (2018) · International Journal of Pharmaceutics · doi:10.1016/j.ijpharm.2017.12.003 · Cited by 233
Scanning electron microscopy 1928–1965
McMullan, D. (1995) · Scanning · doi:10.1002/sca.4950170309 · Cited by 229
PIV-Measured Versus CFD-Predicted Flow Dynamics in Anatomically Realistic Cerebral Aneurysm Models
Ford, M. D., Nikolov, H. N., Milner, J. S., Lownie, S. P., DeMont, E. M., Kalata, W., Loth, F., Holdsworth, D. W., & Steinman, D. A. (2008) · Journal of Biomechanical Engineering · doi:10.1115/1.2900724 · Cited by 209
Lima, R., Wada, S., Tanaka, S., Takeda, M., Ishikawa, T., Tsubota, K.-I., Imai, Y., & Yamaguchi, T. (2008) · Biomedical Microdevices · doi:10.1007/s10544-007-9121-z · Cited by 201
Self-citationPDMS membranes with tunable gas permeability for microfluidic applications
Lamberti, A., Marasso, S. L., & Cocuzza, M. (2014) · RSC Adv. · doi:10.1039/c4ra12934b · Cited by 189
Gokaltun, A., Yarmush, M. L., Asatekin, A., & Usta, O. B. (2017) · TECHNOLOGY · doi:10.1142/s2339547817300013 · Cited by 183
Surface Modification Techniques for Endothelial Cell Seeding in PDMS Microfluidic Devices
Akther, F., Yakob, S. B., Nguyen, N.-T., & Ta, H. T. (2020) · Biosensors · doi:10.3390/bios10110182 · Cited by 182
Photolithographic surface micromachining of polydimethylsiloxane (PDMS)
Chen, W., Lam, R. H. W., & Fu, J. (2012) · Lab Chip · doi:10.1039/c1lc20721k · Cited by 180
Study of PDMS characterization and its applications in biomedicine: A review
Apolónia, S., Victor, A., Bragança, Portugal, andrews.va.souza@alunos.ipb.pt, Ribeiro, J., jribeiro@ipb.pt, C. S. A., F. Araújo, F., & fernando.araujo@cefet-rj.br, C. C. A. D. R. D. J. (2019) · Journal of Mechanical Engineering and Biomechanics · doi:10.24243/jmeb/4.1.163 · Cited by 173
Self-citationLiu, J., Yao, Y., Li, X., & Zhang, Z. (2021) · Chemical Engineering Journal · doi:10.1016/j.cej.2020.127262 · Cited by 171
A circular cross-section PDMS microfluidics system for replication of cardiovascular flow conditions
Fiddes, L. K., Raz, N., Srigunapalan, S., Tumarkan, E., Simmons, C. A., Wheeler, A. R., & Kumacheva, E. (2010) · Biomaterials · doi:10.1016/j.biomaterials.2010.01.082 · Cited by 170
Rapid, simple, and cost-effective treatments to achieve long-term hydrophilic PDMS surfaces
Hemmilä, S., Cauich-Rodríguez, J. V., Kreutzer, J., & Kallio, P. (2012) · Applied Surface Science · doi:10.1016/j.apsusc.2012.06.044 · Cited by 164
Catarino, S. O., Rodrigues, R. O., Pinho, D., Miranda, J. M., Minas, G. M. H., & Lima, R. A. (2019) · Micromachines · doi:10.3390/mi10090593 · Cited by 157
Self-citationMakamba, H., Hsieh, Y.-Y., Sung, W., & Chen, S. (2005) · Analytical Chemistry · doi:10.1021/ac0502706 · Cited by 137
Hong, J., Lee, J., Hong, C. K., & Shim, S. E. (2009) · Current Applied Physics · doi:10.1016/j.cap.2009.06.028 · Cited by 129
Super‐Soft Hydrogel Particles with Tunable Elasticity in a Microfluidic Blood Capillary Model
Cui, J., Björnmalm, M., Liang, K., Xu, C., Best, J. P., Zhang, X., & Caruso, F. (2014) · Advanced Materials · doi:10.1002/adma.201402753 · Cited by 125
Blättler, T. M., Pasche, S., Textor, M., & Griesser, H. J. (2006) · Langmuir · doi:10.1021/la0602766 · Cited by 119
Boxshall, K., Wu, M., Cui, Z., Cui, Z., Watts, J. F., & Baker, M. (2006) · Surface and Interface Analysis · doi:10.1002/sia.2274 · Cited by 117
Carta, R., Jourand, P., Hermans, B., Thoné, J., Brosteaux, D., Vervust, T., Bossuyt, F., Axisa, F., Vanfleteren, J., & Puers, R. (2009) · Sensors and Actuators A Physical · doi:10.1016/j.sna.2009.03.012 · Cited by 113
Geoghegan, P. H., Buchmann, N., Spence, C. J. T., Moore, S., & Jermy, M. (2012) · Experiments in Fluids · doi:10.1007/s00348-011-1258-0 · Cited by 112
Bento, D., Rodrigues, R. O., Faustino, V., Pinho, D., Fernandes, C. S., Pereira, A. I., Garcia, V., Miranda, J. M., & Lima, R. A. (2018) · Micromachines · doi:10.3390/mi9040151 · Cited by 108
Self-citationWu, M., Urban, J. P. G., Cui, Z., & Cui, Z. F. (2006) · Biomedical Microdevices · doi:10.1007/s10544-006-9597-y · Cited by 107
Yang, Y. S., Kulangara, K., Lam, R. T. S., Dharmawan, R., & Leong, K. W. (2012) · ACS Nano · doi:10.1021/nn301713d · Cited by 107
Polymers in modern ophthalmic implants—Historical background and recent advances
Bozukova, D., Pagnoulle, C., Jérôme, R., & Jérôme, C. (2010) · Materials Science and Engineering R Reports · doi:10.1016/j.mser.2010.05.002 · Cited by 93
Adhesion promotion between PDMS and glass by oxygen plasma pre-treatment
Xiong, L., Chen, P., & Zhou, Q. (2014) · Journal of Adhesion Science and Technology · doi:10.1080/01694243.2014.883774 · Cited by 92
She, S., Li, Q., Shan, B., Tong, W., & Gao, C. (2013) · Advanced Materials · doi:10.1002/adma.201302875 · Cited by 91
A Self‐Assembly Approach to Chemical Micropatterning of Poly(dimethylsiloxane)
van Poll, M. L., Zhou, F., Ramstedt, M., Hu, L., & Huck, W. T. S. (2007) · Angewandte Chemie International Edition · doi:10.1002/anie.200702286 · Cited by 89
Fourier transform infrared spectroscopy of polymers
Koenig, J. L. (1984) · Advances in polymer science · doi:10.1007/3-540-12591-4_6 · Cited by 87
Guo, R., & Liu, J. (2017) · Journal of Micromechanics and Microengineering · doi:10.1088/1361-6439/aa891c · Cited by 87
Asymmetry of red blood cell motions in a microchannel with a diverging and converging bifurcation
Leble, V., Lima, R. A., Dias, R. P., Fernandes, C. S., Ishikawa, T., Imai, Y., & Yamaguchi, T. (2011) · Biomicrofluidics · doi:10.1063/1.3672689 · Cited by 81
Self-citationKuddannaya, S., Bao, J., & Zhang, Y. (2015) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.5b09032 · Cited by 80
Evaluation of the biocompatibility of a coating material for an implantable bladder volume sensor
Kim, S., Lee, D. S., Kim, I. J., Sohn, D., Park, J., Choi, B., & Kim, S. (2012) · The Kaohsiung Journal of Medical Sciences · doi:10.1016/j.kjms.2011.10.016 · Cited by 78
Barthès, J., Lagarrigue, P., Riabov, V., Lutzweiler, G., Kirsch, J., Muller, C. B., Courtial, E., Marquette, C. A., Projetti, F., Kzhyskowska, J., et al. (2020) · Biomaterials · doi:10.1016/j.biomaterials.2020.120549 · Cited by 77
A simple microfluidic device for the deformability assessment of blood cells in a continuous flow
Rodrigues, R. O., Pinho, D., Faustino, V., & Lima, R. A. (2015) · Biomedical Microdevices · doi:10.1007/s10544-015-0014-2 · Cited by 74
Self-citationFaustino, V., Rodrigues, R. O., Pinho, D., Costa, E. M., Santos‐Silva, A., Miranda, V. M. P., Amaral, J. S., & Lima, R. A. (2019) · Micromachines · doi:10.3390/mi10100645 · Cited by 73
Self-citationSterilization and Disinfection of Biomaterials for Medical Devices
Harrington, R. E., Guda, T., Lambert, B., & Martin, J. (2020) · Elsevier eBooks · doi:10.1016/b978-0-12-816137-1.00091-x · Cited by 68
Rodrigues, R. O., Bañobre‐López, M., Gallo, J., Tavares, P. B., Silva, A. M. T., Lima, R. A., & Gomes, H. T. (2016) · Journal of Nanoparticle Research · doi:10.1007/s11051-016-3498-7 · Cited by 67
Self-citationA microfluidic device for partial cell separation and deformability assessment
Pinho, D., Yaginuma, T., & Lima, R. A. (2013) · BioChip Journal · doi:10.1007/s13206-013-7408-0 · Cited by 62
Self-citationDual surface modification of PDMS-based silicone implants to suppress capsular contracture
Yoo, B. Y., Kim, B. H., Lee, J. S., Shin, B. H., Kwon, H., Koh, W., & Heo, C. Y. (2018) · Acta Biomaterialia · doi:10.1016/j.actbio.2018.06.022 · Cited by 62
Jinia, A. J., Sunbul, N. B., Meert, C. A., et al. (2020) · IEEE Access · doi:10.1109/access.2020.3002886 · Cited by 61
Choi, J. S., Piao, Y., & Seo, T. S. (2013) · Bioprocess and Biosystems Engineering · doi:10.1007/s00449-013-0961-z · Cited by 60
Boas, L. V., Faustino, V., Lima, R. A., Miranda, J. M., Minas, G. M. H., Fernandes, C. S., & Catarino, S. O. (2018) · Micromachines · doi:10.3390/mi9080384 · Cited by 52
Self-citationVascular Pressure–Flow Measurement Using CB-PDMS Flexible Strain Sensor
Chong, H., Lou, J., Bogie, K. M., Zorman, C. A., & Majerus, S. J. A. (2019) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2019.2946519 · Cited by 52
Role of superhydrophobic coatings in biomedical applications
Kumar, R., & Sahani, A. K. (2021) · Materials Today Proceedings · doi:10.1016/j.matpr.2021.02.457 · Cited by 49
Wang, B., Liu, H., Zhang, B., Han, Y., Shen, C., Lin, Q., & Chen, H. (2016) · Colloids and Surfaces B Biointerfaces · doi:10.1016/j.colsurfb.2016.02.021 · Cited by 47
Doutel, E., Viriato, N., Carneiro, J., Campos, J. B. L. M., & Miranda, J. M. (2019) · International Journal for Numerical Methods in Biomedical Engineering · doi:10.1002/cnm.3207 · Cited by 45
Zhang, Z., Feng, X., Xu, F., Liu, X., & Liu, B. (2010) · Electrophoresis · doi:10.1002/elps.201000208 · Cited by 42
Muñoz-Sánchez, B. N., Silva, S. F., Pinho, D., Vega, E. J., & Lima, R. A. (2016) · Biomicrofluidics · doi:10.1063/1.4943007 · Cited by 42
Self-citationMechanical response of red blood cells entering a constriction
Zeng, N. F., & Ristenpart, W. D. (2014) · Biomicrofluidics · doi:10.1063/1.4904058 · Cited by 37
Li, Y., Verrelli, D. I., Yang, W. W., Qian, Y., & Chong, W. (2019) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2019.109590 · Cited by 36
Carvalho, V. M., Maia, I., Souza, A., Ribeiro, J., Costa, P. F., Puga, H., Teixeira, S., & Lima, R. A. (2020) · The Open Biomedical Engineering Journal · doi:10.2174/1874120702014010087 · Cited by 34
Self-citationFabrication of stable biomimetic coating on PDMS surface: Cooperativity of multivalent interactions
Zhao, Y., Wen, J., Ge, Y., Zhang, X., Shi, H., Yang, K., Gao, X. Y., Shi, S., & Gong, Y. (2018) · Applied Surface Science · doi:10.1016/j.apsusc.2018.11.056 · Cited by 32
Sales, F., Souza, A., Ariati, R. M., Noronha, V. T., Giovanetti, E., Lima, R. A., & Ribeiro, J. (2021) · Journal of Composites Science · doi:10.3390/jcs5040110 · Cited by 32
Self-citationStructure Governs the Deformability of Polymer Particles in a Microfluidic Blood Capillary Model
Sun, H., Björnmalm, M., Cui, J., Wong, E. H. H., Dai, Y., Dai, Q., Qiao, G. G., & Caruso, F. (2015) · ACS Macro Letters · doi:10.1021/acsmacrolett.5b00591 · Cited by 31
Endothelialization of PDMS-based microfluidic devices under high shear stress conditions
Siddique, A., Pause, I., Narayan, S., Kruse, L. D., & Stark, R. W. (2020) · Colloids and Surfaces B Biointerfaces · doi:10.1016/j.colsurfb.2020.111394 · Cited by 28
Genetic correlates of wall shear stress in a patient-specific 3D-printed cerebral aneurysm model
Levitt, M. R., Mandrycky, C., Abel, A. N., Kelly, C. M., Lévy, S., Chivukula, V. K., Zheng, Y. Y., Aliseda, A., & Kim, L. J. (2019) · Journal of NeuroInterventional Surgery · doi:10.1136/neurintsurg-2018-014669 · Cited by 27
Urethanes PDMS-based: Functional hybrid coatings for metallic dental implants
de Aguiar, K. M. F. R., Nascimento, M. V., Faccioni, J. L., Noeske, P.-L. M., Gätjen, L., Rischka, K., & Filho, U. P. R. (2019) · Applied Surface Science · doi:10.1016/j.apsusc.2019.04.058 · Cited by 27
Biomechanical analysis of PDMS channels using different hyperelastic numerical constitutive models
Cardoso, C., Fernandes, C. S., Lima, R. A., & Ribeiro, J. (2018) · Mechanics Research Communications · doi:10.1016/j.mechrescom.2018.04.007 · Cited by 25
Self-citationFABRICATION OF 3D MILI-SCALE CHANNELS FOR HEMODYNAMIC STUDIES
Doutel, E., Carneiro, J., Oliveira, M. S. N., Campos, J. B. L. M., & Miranda, J. M. (2014) · Journal of Mechanics in Medicine and Biology · doi:10.1142/s0219519415500049 · Cited by 25
Biocompatibility of a PDMS-coated micro-device: Bladder volume monitoring sensor
Lee, D. S., Kim, S. J., Sohn, J. H., Kim, I. G., Kim, S. W., Sohn, D. W., Kim, J. H., & Choi, B. (2012) · Chinese Journal of Polymer Science · doi:10.1007/s10118-012-1119-1 · Cited by 24
In Vitro Study of Particle Transport in Successively Bifurcating Vessels
Amili, O., Golzarian, J., & Coletti, F. (2019) · Annals of Biomedical Engineering · doi:10.1007/s10439-019-02293-2 · Cited by 22
López, M., Rubio, M., Sadek, S. H., et al. (2020) · Powder Technology · doi:10.1016/j.powtec.2020.03.022 · Cited by 22
Nguyen, T. Q., & Park, W. (2020) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2020.128590 · Cited by 22
Cited by
Liu, S., Yang, D. S., Wang, S., Luan, H., Sekine, Y., Model, J. B., Aranyosi, A. J., Ghaffari, R., & Rogers, J. A. (2023) · EcoMat · doi:10.1002/eom2.12270 · Cited by 60
Carrillo-Barragán, P., Fitzsimmons, C., Lloyd-Hartley, H., Tinlin-Mackenzie, A., Scott, C., & Sugden, H. (2024) · Environmental Pollution · doi:10.1016/j.envpol.2023.123060 · Cited by 23
Metadata
- Authors
- Miranda, I., Souza, A., Sousa, P., Ribeiro, J., Castanheira, E. M. S., Lima, R., & Minas, G.
- Venue
- Journal of Functional Biomaterials
- Publisher
- MDPI AG
- Published
- 2021-12-21
- Volume
- 13
- Issue
- 1
- Pages
- 2
- ISSN
- 2079-4983 (ISSN-L)
- OpenAlex
- W4200585601
- Cited by
- 824
- References
- 102
- FWCI
- 27.44
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.