Breath Analysis as a Potential and Non-Invasive Frontier in Disease Diagnosis: An Overview
Open accessThe DOI matches its Crossref record; 246 of the 246 references it cites were found in a registry or an index.
Abstract
Currently, a small number of diseases, particularly cardiovascular (CVDs), oncologic (ODs), neurodegenerative (NDDs), chronic respiratory diseases, as well as diabetes, form a severe burden to most of the countries worldwide. Hence, there is an urgent need for development of efficient diagnostic tools, particularly those enabling reliable detection of diseases, at their early stages, preferably using non-invasive approaches. Breath analysis is a non-invasive approach relying only on the characterisation of volatile composition of the exhaled breath (EB) that in turn reflects the volatile composition of the bloodstream and airways and therefore the status and condition of the whole organism metabolism. Advanced sampling procedures (solid-phase and needle traps microextraction) coupled with modern analytical technologies (proton transfer reaction mass spectrometry, selected ion flow tube mass spectrometry, ion mobility spectrometry, e-noses, etc.) allow the characterisation of EB composition to an unprecedented level. However, a key challenge in EB analysis is the proper statistical analysis and interpretation of the large and heterogeneous datasets obtained from EB research. There is no standard statistical framework/protocol yet available in literature that can be used for EB data analysis towards discovery of biomarkers for use in a typical clinical setup. Nevertheless, EB analysis has immense potential towards development of biomarkers for the early disease diagnosis of diseases.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Siegel, R., Naishadham, D., & Jemal, A. (2012) · CA: A Cancer Journal for Clinicians · doi:10.3322/caac.20138 · Cited by 10,679
A tutorial on spectral clustering
von Luxburg, U. (2007) · Statistics and Computing · doi:10.1007/s11222-007-9033-z · Cited by 10,349
PLS-regression: a basic tool of chemometrics
Wold, S., Sjöström, M., & Eriksson, L. (2001) · Chemometrics and Intelligent Laboratory Systems · doi:10.1016/s0169-7439(01)00155-1 · Cited by 10,084 · cited 1×
“Partial least-square (PLS) was originally developed for the quantitative analysis in regression problems [260], but its ability to cope with highly collinear data made it also very suitable for breath analysis [261].”
MethodTowards complete and accurate reporting of studies of diagnostic accuracy: The STARD Initiative.
Bossuyt, P. M., Reitsma, J. B., Bruns, D. E., Gatsonis, C. A., Glasziou, P. P., Irwig, L. M., Lijmer, J. G., Moher, D., Rennie, D., de Vet, H. C. W., et al. (2003) · Annals of Internal Medicine · doi:10.7326/0003-4819-138-1-200301070-00010 · Cited by 3,219
Towards complete and accurate reporting of studies of diagnostic accuracy: the STARD initiative
Bossuyt, P. M., Reitsma, J. B., Bruns, D. E., Gatsonis, C. A., Glasziou, P. P., Irwig, L. M., Lijmer, J. G., Moher, D., Rennie, D., & de Vet, H. C. W. (2003) · BMJ · doi:10.1136/bmj.326.7379.41 · Cited by 3,215
Towards Complete and Accurate Reporting of Studies of Diagnostic Accuracy: The STARD Initiative
Bossuyt, P. M., Reitsma, J. B., Bruns, D. E., Gatsonis, C. A., Glasziou, P. P., Irwig, L. M., Lijmer, J. G., Moher, D., Rennie, D., & de Vet, H. C. W. (2003) · Radiology · doi:10.1148/radiol.2261021292 · Cited by 3,215
Dweik, R. A., Boggs, P. B., Erzurum, S. C., Irvin, C. G., Leigh, M. W., Lundberg, J. O., Olin, A.-C., Plummer, A. L., & Taylor, D. R. (2011) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.9120-11st · Cited by 2,539
Obesity and Diabetes in the Developing World — A Growing Challenge
Hossain, P., Kawar, B., & El Nahas, M. (2007) · New England Journal of Medicine · doi:10.1056/nejmp068177 · Cited by 2,200
HMDB: a knowledgebase for the human metabolome
Wishart, D. S., Knox, C., Guo, A. C., Eisner, R., Young, N., Gautam, B., Hau, D. D., Psychogios, N., Dong, E., Bouatra, S., et al. (2009) · Nucleic Acids Research · doi:10.1093/nar/gkn810 · Cited by 1,873
Biological and chemical sensors based on graphene materials
Liu, Y., Dong, X., & Chen, P. (2012) · Chem. Soc. Rev. · doi:10.1039/c1cs15270j · Cited by 1,748
Cited by
Sensors for Volatile Organic Compounds
Khatib, M., & Haick, H. (2022) · ACS Nano · doi:10.1021/acsnano.1c10827 · Cited by 533
Recent advances in wearable sensors for animal health management
Neethirajan, S. (2017) · Sensing and Bio-Sensing Research · doi:10.1016/j.sbsr.2016.11.004 · Cited by 502
Progress in the development of semiconducting metal oxide gas sensors: a review
Moseley, P. T. (2017) · Measurement Science and Technology · doi:10.1088/1361-6501/aa7443 · Cited by 327
Quartz-enhanced photoacoustic spectroscopy for multi-gas detection: A review
Sampaolo, A., Patimisco, P., Giglio, M., Zifarelli, A., Wu, H., Dong, L., & Spagnolo, V. (2022) · Analytica Chimica Acta · doi:10.1016/j.aca.2021.338894 · Cited by 229
Yoon, J.-W., & Lee, J.-H. (2017) · Lab Chip · doi:10.1039/c7lc00810d · Cited by 222
Recent advancement in biosensors technology for animal and livestock health management
Neethirajan, S., Tuteja, S. K., Huang, S.-T., & Kelton, D. (2017) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2017.07.015 · Cited by 201
Metabolome analysis for investigating host-gut microbiota interactions
Chen, M. X., Wang, S.-Y., Kuo, C.-H., & Tsai, I.-L. (2019) · Journal of the Formosan Medical Association · doi:10.1016/j.jfma.2018.09.007 · Cited by 192
Mass spectrometry for real-time quantitative breath analysis
Smith, D., Španěl, P., Herbig, J., & Beauchamp, J. (2014) · Journal of Breath Research · doi:10.1088/1752-7155/8/2/027101 · Cited by 174
Humidity-activated ammonia sensor with excellent selectivity for exhaled breath analysis
Liu, L., Fei, T., Guan, X., Zhao, H., & Zhang, T. (2021) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2021.129625 · Cited by 100
Liu, L., Fei, T., Guan, X., Zhao, H., & Zhang, T. (2021) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2021.113459 · Cited by 60
Peel, A. M., Wilkinson, M., Sinha, A., Loke, Y. K., Fowler, S. J., & Wilson, A. M. (2020) · Respiratory Medicine · doi:10.1016/j.rmed.2020.105984 · Cited by 40
“Although strategies for avoiding false discoveries (68) and minimum reporting standards for data analysis in metabolomics (69) have been published, there is no standard statistical framework for analyses (70); the ERS technical standards are not prescriptive in this respect.”
Raninen, K., Lappi, J., Kolehmainen, M., Kolehmainen, M., Mykkänen, H., Poutanen, K., & Raatikainen, O. (2017) · International Journal of Food Sciences and Nutrition · doi:10.1080/09637486.2017.1312296 · Cited by 15
“Breath research has traditionally been focussed on finding specific biomarker compounds for diseases (Kurada et al. 2015; Pereira et al. 2015; Schmidt & Podmore 2015; van der Schee et al. 2015), but this is challenging because of large inter-individual variation in breath volatile organic compounds…”
Background
Metadata
- Authors
- Pereira, J., Porto-Figueira, P., Cavaco, C., Taunk, K., Rapole, S., Dhakne, R., Nagarajaram, H., & Câmara, J.
- Venue
- Metabolites
- Publisher
- MDPI AG
- Published
- 2015-01-09
- Volume
- 5
- Issue
- 1
- Pages
- 3-55
- ISSN
- 2218-1989 (ISSN-L)
- OpenAlex
- W2012558417
- Cited by
- 301
- References
- 246
- FWCI
- 10.69
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.