Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 46

The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.

Polyetheretherketone Hybrid Composites with Bioactive Nanohydroxyapatite and Multiwalled Carbon Nanotube Fillers

Liu, Chen, Chan, Kai, Shen, Jie, Liao, Cheng, Yeung, Kelvin, Tjong, Sie · 2016 · Polymers

Abstract

Polyetheretherketone (PEEK) hybrid composites reinforced with inorganic nanohydroxyapatite (nHA) and multiwalled carbon nanotube (MWNT) were prepared by melt-compounding and injection molding processes. The additions of nHA and MWNT to PEEK were aimed to increase its elastic modulus, tensile strength, and biocompatibility, rendering the hybrids suitable for load-bearing implant applications. The structural behavior, mechanical property, wettability, osteoblastic cell adhesion, proliferation, differentiation, and mineralization of the PEEK/nHA-MWNT hybrids were studied. X-ray diffraction and SEM observation showed that both nHA and MWNT fillers are incorporated into the polymer matrix of PEEK-based hybrids. Tensile tests indicated that the elastic modulus of PEEK can be increased from 3.87 to 7.13 GPa by adding 15 vol % nHA and 1.88 vol % MWNT fillers. The tensile strength and elongation at break of the PEEK/(15% nHA)-(1.88% MWNT) hybrid were 64.48 MPa and 1.74%, respectively. Thus the tensile properties of this hybrid were superior to those of human cortical bones. Water contact angle measurements revealed that the PEEK/(15% nHA)-(1.88% MWNT) hybrid is hydrophilic due to the presence of nHA. Accordingly, hydrophilic PEEK/(15% nHA)-(1.88% MWNT) hybrid promoted the adhesion, proliferation, differentiation, and mineralization of murine MC3T3-E1 osteoblasts on its surface effectively on the basis of cell culture, fluorescence microscopy, MTT assay, WST-1 assay, alkaline phosphatase activity, and Alizarin red staining tests. Thus the PEEK/(15% nHA)-(1.88% MWNT) hybrid has the potential to be used for fabricating load-bearing bone implants.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.3390/polym8120425

Cites

6 of 6 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 6 references

Research works printed but not linked: 44

  1. Yu, 2015, Biomaterials for bone regenerative engineering, Adv. Healthc. Mater., 24, 1268, 10.1002/adhm.201400760 · DOI · Paper page
  2. Hallab, 2001, Metal sensitivity in patients with orthopedic implants, J. Bone Jt. Surg. Am., 83A, 428, 10.2106/00004623-200103000-00017 · DOI · Paper page
  3. Okazaki, 2005, Comparison of metal release from various metallic biomaterials in vitro, Biomaterials, 26, 11, 10.1016/j.biomaterials.2004.02.005 · DOI · Paper page
  4. Scharf, 2014, Molecular analysis of chromium and cobalt-related toxicity, Sci. Rep., 4, 5729, 10.1038/srep05729 · DOI · Paper page
  5. Tjong, 1981, ESCA and SIMS studies of the passive film on iron, J. Electrochem. Soc., 128, 2251, 10.1149/1.2127229 · DOI
  6. Tjong, 1982, Electron and ion spectroscopic studies of the passive film on iron-chromium alloys, J. Electrochem. Soc., 129, 1662, 10.1149/1.2124232 · DOI
  7. Huang, 1997, In vitro mechanical and biological assessment of hydroxyapatite-reinforced polyethylene composite, J. Mater. Sci. Mater. Med., 8, 775, 10.1023/A:1018516813604 · DOI
  8. Meng, 1998, Rheology and morphology of compatibilized polyamide 6 blends containing liquid crystalline copolyesters, Polymer, 39, 99, 10.1016/S0032-3861(97)00218-8 · DOI
  9. Tjong, 1996, Mechanical properties of injection moulded blends of polypropylene with thermotropic liquid crystalline polymer, J. Mater. Sci., 31, 479, 10.1007/BF01139167 · DOI
  10. Du, 2004, Synthesis and degradation behavior of poly(propylene carbonate) derived from carbon dioxide and propylene oxide, J. Appl. Polym. Sci., 92, 1840, 10.1002/app.20165 · DOI
  11. Naffakh, 2012, High-performance nanocomposites based on polyetherketones, Prog. Mater. Sci., 57, 1106, 10.1016/j.pmatsci.2012.03.003 · DOI · Paper page
  12. Kurtz, 2007, PEEK biomaterials in trauma, orthopedic, and spinal implants, Biomaterials, 28, 4845, 10.1016/j.biomaterials.2007.07.013 · DOI · Paper page
  13. Ajami, S., Coathup, M.J., Khoury, J., and Blunn, G.W. (2016). Augmenting the bioactivity of polyetheretherketone using a novel accelerated neutral atom beam technique. J. Biomed. Mater. Res. B. · doi:10.1002/jbm.b.33681
  14. Lee, 2013, In vitro and in vivo evaluation of the bioactivity of hydroxyapatite-coated polyetheretherketone biocomposites created by cold spray technology, Acta Biomater., 9, 6177, 10.1016/j.actbio.2012.11.030 · DOI · Paper page
  15. Converse, 2007, Processing and tensile properties of hydroxyapatite-whisker-reinforced polyetheretherketone, Biomaterials, 28, 927, 10.1016/j.biomaterials.2006.10.031 · DOI · Paper page
  16. Cheng, 2003, Tensile properties, tension-tension fatigue and biological response of polyetheretherketone-hydroxyapatite composites for load-bearing orthopedic implants, Biomaterials, 24, 2245, 10.1016/S0142-9612(03)00028-0 · doi:10.1016/s0142-9612(03)00028-0
  17. Tjong, S.C. (2009). Advances in Biomedical Science and Engineering, Bentham. · doi:10.2174/97816080504061090101
  18. Zhang, 2009, Nanotechnology and nanomaterials: Promises for improved tissue regeneration, Nano Today, 4, 66, 10.1016/j.nantod.2008.10.014 · DOI · Paper page
  19. Bonfield, 1998, Interfaces in analogue biomaterials, Acta. Mater., 46, 2509, 10.1016/S1359-6454(98)80035-9 · DOI
  20. Liao, 2014, The development, fabrication and material characterization of polypropylene composites reinforced with carbon nanofiber and hydroxyapatite nanorod hybrid fillers, Int. J. Nanomed., 9, 1299
  21. Li, 2012, Sintered hydroxyapatite/polyetheretherketone nanocomposites: Mechanical behavior and biocompatibility, Adv. Eng. Mater., 14, B155, 10.1002/adem.201080145 · doi:10.1002/adem.201080145
  22. Chan, 2016, Preparation of polyetheretherketone composites with nanohydroxyapatite rods and carbon nanofibers having high strength, good biocompatibility and excellent thermal stability, RSC Adv., 6, 19417, 10.1039/C5RA22134J · DOI
  23. Liu, C., Wong, H.M., Yeung, K.W., and Tjong, S.C. (2016). Novel electrospun polylactic acid nanocomposite fiber mats with hybrid graphene oxide and nanohydroxyapatite reinforcements having enhanced biocompatibility. Polymers, 8. · DOI
  24. Venkatesan, 2014, Nano-hydroxyapatite composite biomaterials for bone tissue engineering-A review, J. Biomed. Nanotechnol., 10, 3124, 10.1166/jbn.2014.1893 · DOI · Paper page
  25. Sun, 2011, Various preparation methods of highly porous hydroxyapatite/polymer nanoscale biocomposites for bone regeneration, Acta Biomater., 7, 3813, 10.1016/j.actbio.2011.07.002 · DOI · Paper page
  26. Ma, 2014, Preparation, characterization, and in vitro osteoblast functions of a nano-hydroxyapatite/polyetheretherketone biocomposite as orthopedic implant material, Int. J. Nanomed., 9, 3949
  27. Demczyk, 2002, Direct mechanical measurement of the tensile strength and elastic modulus of multiwalled carbon nanotubes, Mater. Sci. Eng. A, 334, 173, 10.1016/S0921-5093(01)01807-X · DOI · Paper page
  28. Usui, 2008, Carbon nanotubes with high bone-tissue compatibility and bone-formation acceleration effects, Small, 4, 240, 10.1002/smll.200700670 · doi:10.1002/smll.200700670
  29. Blundell, 1983, The morphology of poly(aryl-ether-ether-ketone), Polymer, 24, 953, 10.1016/0032-3861(83)90144-1 · DOI
  30. Tzavalas, 2008, Polyethylene terephthalate-multiwall nanotubes nanocomposites: Effect of nanotubes on the conformations, crystallinity and crystallization behavior of PET, J. Polym. Sci. B Polym. Phys., 46, 668, 10.1002/polb.21378 · doi:10.1002/polb.21378
  31. Lee, 1998, Interaction of different types of cells on polymer surfaces with wettability gradient, J. Colloid Interface Sci., 205, 323, 10.1006/jcis.1998.5688 · DOI · Paper page
  32. Arima, 2007, Effect of wettability and surface functional groups on protein adsorption and cell adhesion using well-defined mixed self-assembled monolayers, Biomaterials, 28, 3074, 10.1016/j.biomaterials.2007.03.013 · DOI · Paper page
  33. Hynes, 2002, Integrins: Bidirectional, allosteric signaling machines, Cell, 10, 673, 10.1016/S0092-8674(02)00971-6 · DOI
  34. Palacio, 2012, Bioadhesion: A review of concepts and applications, Philos. Trans. R. Soc. A, 370, 2321, 10.1098/rsta.2011.0483 · DOI
  35. Petit, 2000, Focal adhesions: Structure and dynamics, Biol. Cell, 92, 477, 10.1016/S0248-4900(00)01101-1 · DOI · Paper page
  36. Chen, 1994, Integrin-mediated cell adhesion activates mitogen-activated protein kinase, J. Biol. Chem., 269, 26602, 10.1016/S0021-9258(18)47058-5 · DOI · Paper page
  37. Kaspers, 2011, Cell sensitivity assays: The MTT assay, Methods Mol. Biol., 731, 237, 10.1007/978-1-61779-080-5_20 · DOI · Paper page
  38. Mwenifumbo, 2007, Exploring cellular behavior with multi-walled carbon nanotube constructs, J. Mater. Chem., 17, 1894, 10.1039/b617708e · DOI
  39. Ren, 2010, Toxicity of single-walled carbon nanotube: How we were wrong?, Mater. Today, 13, 6, 10.1016/S1369-7021(10)70002-X · DOI
  40. Hamilton, 2013, Effect of MWCNT size, carboxylation, and purification on in vitro and in vivo toxicity, inflammation and lung pathology, Part. Fibre Toxicol., 10, 57, 10.1186/1743-8977-10-57 · DOI
  41. Altankov, 1996, Studies on the biocompatibility of materials: Fibroblast reorganization of substratum-bound fibronectin on surfaces varying in wettability, J. Biomed. Mater. Res., 30, 385, 10.1002/(SICI)1097-4636(199603)30:3<385::AID-JBM13>3.0.CO;2-J · DOI · Paper page
  42. Tran, 2009, Nanotechnology for bone materials, Wiley Interdiscip. Rev. Nanomed. Nanobiotechnol., 1, 336, 10.1002/wnan.23 · DOI
  43. Sabokbar, 1994, A rapid, quantitative assay for measuring alkaline phosphatase activity in osteoblastic cells in vitro, Bone Miner., 27, 57, 10.1016/S0169-6009(08)80187-0 · DOI · Paper page
  44. Chang, 2000, Calcium and phosphate supplementation promotes bone cell mineralization: Implications for hydroxyapatite (HA)-enhanced bone formation, J. Biomed. Mater. Res., 52, 270, 10.1002/1097-4636(200011)52:2<270::AID-JBM5>3.0.CO;2-1 · doi:10.1002/1097-4636(200011)52:2<270::aid-jbm5>3.0.co;2-1

Cited by

Metadata

Authors
Liu, C., Chan, K., Shen, J., Liao, C., Yeung, K., & Tjong, S.
Venue
Polymers
Publisher
MDPI AG
Published
2016-12-08
Volume
8
Issue
12
Pages
425
ISSN
2073-4360
Cited by
46
References
6
Language
en
Funders
  • Shenzhen Knowledge Innovation Program of Basic Research Items of Guangdong Province (JCYJ20140414090541811)
  • Shenzhen Science and Technology Project Grant (JCYJ20150630145302228)
  • Applied Research Grant, City University of Hong Kong (9667126)

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.