Design Criteria for Generating Physiologically Relevant In Vitro Models in Bioreactors
Open accessThe DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Abstract
In this paper, we discuss the basic design requirements for the development of physiologically meaningful in vitro systems comprising cells, scaffolds and bioreactors, through a bottom up approach. Very simple micro- and milli-fluidic geometries are first used to illustrate the concepts, followed by a real device case-study. At each step, the fluidic and mass transport parameters in biological tissue design are considered, starting from basic questions such as the minimum number of cells and cell density required to represent a physiological system and the conditions necessary to ensure an adequate nutrient supply to tissues. At the next level, we consider the use of three-dimensional scaffolds, which are employed both for regenerative medicine applications and for the study of cells in environments which better recapitulate the physiological milieu. Here, the driving need is the rate of oxygen supply which must be maintained at an appropriate level to ensure cell viability throughout the thickness of a scaffold. Scaffold and bioreactor design are both critical in defining the oxygen profile in a cell construct and are considered together. We also discuss the oxygen-shear stress trade-off by considering the levels of mechanical stress required for hepatocytes, which are the limiting cell type in a multi-organ model. Similar considerations are also made for glucose consumption in cell constructs. Finally, the allometric approach for generating multi-tissue systemic models using bioreactors is described.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Genomic responses in mouse models poorly mimic human inflammatory diseases
Seok, J., Warren, H. S., Cuenca, A. G., Mindrinos, M. N., Baker, H. V., Xu, W., Richards, D. R., McDonald-Smith, G. P., Gao, H., Hennessy, L., et al. (2013) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1222878110 · Cited by 3,005
Geometric cues for directing the differentiation of mesenchymal stem cells
Kilian, K. A., Bugarija, B., Lahn, B. T., & Mrksich, M. (2010) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0903269107 · Cited by 1,841
Biological implications of polydimethylsiloxane-based microfluidic cell culture
Regehr, K. J., Domenech, M., Koepsel, J. T., Carver, K. C., Ellison-Zelski, S. J., Murphy, W. L., Schuler, L. A., Alarid, E. T., & Beebe, D. J. (2009) · Lab on a Chip · doi:10.1039/b903043c · Cited by 719 · cited 1×
“polymers during the manufacturing of micro-devices, and interact with cells or culture media [29].”
A Review of Three-Dimensional In Vitro Tissue Models for Drug Discovery and Transport Studies
Elliott, N. T., & Yuan, F. (2011) · Journal of Pharmaceutical Sciences · doi:10.1002/jps.22257 · Cited by 449 · cited 1×
“In vitro models have been widely used to simplify the study of complex phenomena of the in vivo environment, creating well-controlled and easily accessible conditions for the quantitative and repeatable evaluation of cell response—moreover, they are quick and require modest amounts of material [1].”
Why animal studies are often poor predictors of human reactions to exposure
Bracken, M. B. (2009) · Journal of the Royal Society of Medicine · doi:10.1258/jrsm.2008.08k033 · Cited by 362 · cited 1×
“processes are significantly different in humans and animals, and that drugs are given to sick, often old humans but tested on healthy and young animals, the utility of this type of regulatory testing, and the use of animals as human-surrogates in general, has recently been questioned [7,8].”
Formation of steady‐state oxygen gradients in vitro: Application to liver zonation
Allen, J. W., & Bhatia, S. N. (2003) · Biotechnology and Bioengineering · doi:10.1002/bit.10569 · Cited by 269
FEM-based oxygen consumption and cell viability models for avascular pancreatic islets
Buchwald, P. (2009) · Theoretical Biology and Medical Modelling · doi:10.1186/1742-4682-6-5 · Cited by 187
Research works printed but not linked: 65
- Cimetta, 2013, Bioengineering heart tissue for in vitro testing, Curr. Opin. Biotechnol., 24, 926, 10.1016/j.copbio.2013.07.002 · DOI · Paper page
- Rouwkema, 2011, In vitro platforms for tissue engineering: Implications for basic research and clinical translation, J. Tissue Eng. Regen. Med., 5, e164, 10.1002/term.414 · DOI
- Astashkina, 2012, A critical evaluation of in vitro cell culture models for high-throughput drug screening and toxicity, Pharmacol. Ther., 134, 82, 10.1016/j.pharmthera.2012.01.001 · DOI · Paper page
- Nerem, 2006, Tissue engineering: The hope, the hype, and the future, Tissue Eng., 12, 1143, 10.1089/ten.2006.12.1143 · DOI
- Shoji, 2004, Nutraceutics and delivery systems, J. Drug Target., 12, 385, 10.1080/10611860400003817 · DOI · Paper page
- Di Nardo, P., Minieri, M., and Ahluwalia, A. (2011). Stem Cell Engineering, Springer.
- Patzer, 2004, Oxygen consumption in a hollow fiber bioartificial liver, Artif. Organs, 28, 83, 10.1111/j.1525-1594.2004.07150.x · DOI
- Schyschka, 2013, Hepatic 3D cultures but not 2D cultures preserve specific transporter activity for acetaminophen-induced hepatotoxicity, Arch. Toxicol., 87, 1581, 10.1007/s00204-013-1080-y · DOI
- Francioli, 2010, Effect of three-dimensional expansion and cell seeding density on the cartilage-forming capacity of human articular chondrocytes in type II collagen sponges, J. Biomed. Mater. Res. A, 95, 924, 10.1002/jbm.a.32917 · DOI
- Iwasa, 2003, Effects of cell density on proliferation and matrix synthesis of chondrocytes embedded in atelocollagen gel, Artif. Organs, 27, 249, 10.1046/j.1525-1594.2003.07073.x · DOI
- Loeve, 2010, About a Definition of Nano: How to Articulate Nano and Technology?, Int. J. Philos. Chem., 6, 3
- Lee, 2008, Three-dimensional cellular microarray for high-throughput toxicology assays, Proc. Natl. Acad. Sci. USA, 105, 59, 10.1073/pnas.0708756105 · DOI · Paper page
- Sung, 2010, In vitro microscale systems for systematic drug toxicity study, Bioprocess Biosyst. Eng., 33, 5, 10.1007/s00449-009-0369-y · DOI
- Sung, 2010, Integration of in silico and in vitro platforms for pharmacokinetic-pharmacodynamic modeling, Expert Opin. Drug Metab. Toxicol., 6, 1063, 10.1517/17425255.2010.496251 · DOI · Paper page
- Wei, 2006, Elucidating in vitro cell-cell interaction using a microfluidic coculture system, Biomed. Microdevices, 8, 65, 10.1007/s10544-006-6384-8 · DOI
- Baudoin, 2007, Trends in the development of microfluidic cell biochips for in vitro hepatotoxicity, Toxicol. In Vitro, 21, 535, 10.1016/j.tiv.2006.11.004 · DOI
- Tingley, 2006, High-throughput cell culture: A real-world evaluation, Innov. Pharm. Technol., 54, 54
- Tilles, 2001, Effects of oxygenation and flow on the viability and function of rat hepatocytes cocultured in a microchannel flat-plate bioreactor, Biotechnol. Bioeng., 73, 379, 10.1002/bit.1071 · DOI · Paper page
- Park, 2008, Radial flow hepatocyte bioreactor using stacked microfabricated grooved substrates, Biotechnol. Bioeng., 99, 455, 10.1002/bit.21572 · DOI · Paper page
- McBeath, 2004, Cell shape, cytoskeletal tension, and RhoA regulate stem cell lineage commitment, Dev. Cell, 6, 483, 10.1016/S1534-5807(04)00075-9 · DOI · Paper page
- Francis, 1997, Effective intercellular communication distances are determined by the relative time constants for cyto/chemokine secretion and diffusion, Proc. Natl. Acad. Sci. USA, 94, 12258, 10.1073/pnas.94.23.12258 · DOI · Paper page
- Lundholt, 2003, A simple technique for reducing edge effect in cell-based assays, J. Biomol. Screening, 8, 566, 10.1177/1087057103256465 · DOI · Paper page
- Toepke, 2006, PDMS absorption of small molecules and consequences in microfluidic applications, Lab Chip, 6, 1484, 10.1039/b612140c · DOI · Paper page
- Mehta, 2009, Quantitative Inference of Cellular Parameters From Microfluidic Cell Culture Systems, Biotechnol. Bioeng., 103, 966, 10.1002/bit.22334 · doi:10.1002/bit.22334
- Mazzei, 2010, A low shear stress modular bioreactor for connected cell culture under high flow rates, Biotechnol. Bioeng., 106, 127, 10.1002/bit.22671 · DOI · Paper page
- Martin, 2005, Bioreactors for tissue mass culture: Design, characterization, and recent advances, Biomaterials, 26, 7481, 10.1016/j.biomaterials.2005.05.057 · DOI · Paper page
- Freshney, I.R. (2010). Culture of Animal Cells: A Manual of Basic Technique and Specialized Applications, Wiley-Blackwell. [6th ed.]. · DOI · Paper page
- Coleman, 1996, Plasticity of the hepatocyte phenotype in vitro: Complex phenotypic transitions in proliferating hepatocyte cultures suggest bipotent differentiation capacity of mature hepatocytes, Hepatology, 24, 1542, 10.1002/hep.510240642 · DOI
- Guillouzo, 1998, Liver cell models in in vitro toxicology, Environ. Health Perspect., 106, 511
- Nahmias, 2007, Integration of technologies for hepatic tissue engineering, Adv. Biochem. Eng. Biotechnol., 103, 309
- Smith, 2007, Hypoxia leads to necrotic hepatocyte death, J. Biomed. Mater. Res. A, 80, 520, 10.1002/jbm.a.30930 · DOI
- Tanaka, 2006, Evaluation of effects of shear stress on hepatocytes by a microchip-based system, Meas. Sci. Technol., 17, 3167, 10.1088/0957-0233/17/12/S08 · DOI · Paper page
- Nakatsuka, 2006, Shear stress induces hepatocyte PAI-1 gene expression through cooperative Sp1/Ets-1 activation of transcription, Am. J. Physiol. Gastrointest. Liver Physiol., 291, G26, 10.1152/ajpgi.00467.2005 · DOI
- Rutkowski, 2007, A driving force for change: Interstitial flow as a morphoregulator, Trends Cell Biol., 17, 44, 10.1016/j.tcb.2006.11.007 · DOI · Paper page
- Swartz, 2007, Interstitial flow and its effects in soft tissues, Annu. Rev. Biomed. Eng., 9, 229, 10.1146/annurev.bioeng.9.060906.151850 · DOI · Paper page
- Nearingburg, 2011, Finite element analysis of oxygen transport in microfluidic cell culture devices with varying channel architectures, perfusion rates, and materials, Chem. Eng. Sci., 66, 6244, 10.1016/j.ces.2011.09.007 · DOI
- Kim, 2013, Mathematical analysis of oxygen transfer through polydimethylsiloxane membrane between double layers of cell culture channel and gas chamber in microfluidic oxygenator, Microfluid. Nanofluidics, 15, 285, 10.1007/s10404-013-1142-8 · DOI · Paper page
- Tan, 2013, A thin-walled polydimethylsiloxane bioreactor for high-density hepatocyte sandwich culture, Biotechnol. Bioeng., 110, 1663, 10.1002/bit.24822 · DOI
- Silbey, R.J., Alberty, R.A., and Bawendi, M.G. (2005). Physical Chemistry, John Wiley & Sons.
- Nyberg, 1994, Primary hepatocytes outperform Hep G2 cells as the source of biotransformation functions in a bioartificial liver, Ann. Surg., 220, 59
- Frisancho, 1975, Functional adaptation to high altitude hypoxia, Science, 187, 313, 10.1126/science.1089311 · DOI · Paper page
- Buchwald, 2011, A local glucose-and oxygen concentration-based insulin secretion model for pancreatic islets, Theor. Biol. Med. Model., 8, 20, 10.1186/1742-4682-8-20 · DOI · Paper page
- Oller, 1989, Growth of mammalian cells at high oxygen concentrations, J. Cell Sci., 94, 43, 10.1242/jcs.94.1.43 · doi:10.1242/jcs.94.1.43
- Haselgrove, 1993, Computer modeling of the oxygen supply and demand of cells of the avian growth cartilage, Am. J. Physiol., 265, C497, 10.1152/ajpcell.1993.265.2.C497 · DOI
- Mehmetoglu, 1996, Oxygen diffusivity in calcium alginate gel beads containing Gluconobacter suboxydans, Artif. Cells Blood Substit. Immobil. Biotechnol., 24, 91, 10.3109/10731199609118877 · DOI
- Hulst, 1989, Determination of the effective diffusion coefficient of oxygen in gel materials in relation to gel concentration, Biotechnol. Tech., 3, 199, 10.1007/BF01875620 · doi:10.1007/bf01875620
- Ehsan, 2013, Nonsteady state oxygen transport in engineered tissue: Implications for design, Tissue Eng. A, 19, 1433, 10.1089/ten.tea.2012.0587 · DOI
- Everaerts, 1993, Diffusion coefficients of oxygen, hydrogen peroxide and glucose in a hydrogel, Anal. Chim. Acta, 273, 553, 10.1016/0003-2670(93)80202-V · doi:10.1016/0003-2670(93)80202-v
- Foy, 1994, A device to measure the oxygen uptake rate of attached cells: Importance in bioartificial organ design, Cell Transplant., 3, 515, 10.1177/096368979400300609 · DOI · Paper page
- De Groot, H., Littauer, A., and Noll, T. (1988). Oxygen Sensors Tissues, Springer.
- Vinci, 2010, Flow-regulated glucose and lipid metabolism in adipose tissue, endothelial cell and hepatocyte cultures in a modular bioreactor, Biotechnol. J., 5, 618, 10.1002/biot.201000009 · DOI
- Vinci, 2011, Modular bioreactor for primary human hepatocyte culture: Medium flow stimulates expression and activity of detoxification genes, Biotechnol. J., 6, 554, 10.1002/biot.201000326 · DOI · Paper page
- Vinci, 2012, An in vitro model of glucose and lipid metabolism in a multicompartmental bioreactor, Biotechnol. J., 7, 117, 10.1002/biot.201100177 · DOI
- Vinci, 2010, In vitro liver model using microfabricated scaffolds in a modular bioreactor, Biotechnol. J., 5, 232, 10.1002/biot.200900074 · DOI · Paper page
- Guzzardi, 2011, Metabolic control through hepatocyte and adipose tissue cross-talk in a multicompartmental modular bioreactor, Tissue Eng. A, 17, 1635, 10.1089/ten.tea.2010.0541 · DOI · Paper page
- Giulitti, 2013, Optimal periodic perfusion strategy for robust long-term microfluidic cell culture, Lab Chip, 13, 4430, 10.1039/c3lc50643f · DOI · Paper page
- Nishikawa, 2008, Enhanced maintenance and functions of rat hepatocytes induced by combination of on-site oxygenation and coculture with fibroblasts, J. Biotechnol., 133, 253, 10.1016/j.jbiotec.2007.08.041 · DOI
- Skolimowski, 2010, Microfluidic dissolved oxygen gradient generator biochip as a useful tool in bacterial biofilm studies, Lab Chip, 10, 2162, 10.1039/c003558k · DOI · Paper page
- Cimetta, 2007, Enhancement of viability of muscle precursor cells on 3D scaffold in a perfusion bioreactor, Int. J. Artif. Organs, 30, 415, 10.1177/039139880703000509 · DOI
- Iskander, 2009, Laminar Flow and Heat Transfer of Herschel-Bulkley Fluids in a Rectangular Duct; Finite-Element Analysis, Tikrit J. Sci. Eng., 12, 99
- Weibel, 2004, Allometric scaling of maximal metabolic rate in mammals: Muscle aerobic capacity as determinant factor, Respir. Physiol. Neurobiol., 140, 115, 10.1016/j.resp.2004.01.006 · DOI · Paper page
- 2006, Determination of the hepatocellularity number for human, dog, rabbit, rat and mouse livers from protein concentration measurements, Toxicol. In Vitro, 20, 1582, 10.1016/j.tiv.2006.06.003 · DOI · Paper page
- Sbrana, 2012, Engineering Quasi-Vivo in vitro organ models, Adv. Exp. Med. Biol., 745, 138, 10.1007/978-1-4614-3055-1_9 · DOI
- Vozzi, 2011, A flexible bioreactor system for constructing in vitro tissue and organ models, Biotechnol. Bioeng., 108, 2129, 10.1002/bit.23164 · DOI
- Haycock, J., Ahluwalia, A., and Wilkinson, M.J. (2014). Cellular In Vitro Testing: Methods and Protocols, Pan Stanford Publishing Pte. Ltd. · doi:10.1201/b15630
Cited by
3D Printing of Personalized Thick and Perfusable Cardiac Patches and Hearts
Noor, N., Shapira, A., Edri, R., Gal, I., Wertheim, L., & Dvir, T. (2019) · Advanced Science · doi:10.1002/advs.201900344 · Cited by 1,042
A liver-on-a-chip platform with bioprinted hepatic spheroids
Bhise, N. S., Manoharan, V., Massa, S., Tamayol, A., Ghaderi, M., Miscuglio, M., Lang, Q., Shrike Zhang, Y., Shin, S. R., Calzone, G., et al. (2016) · Biofabrication · doi:10.1088/1758-5090/8/1/014101 · Cited by 615
Tissue Engineering Approaches in the Design of Healthy and Pathological In Vitro Tissue Models
Caddeo, S., Boffito, M., & Sartori, S. (2017) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2017.00040 · Cited by 285
Retinal organoids on-a-chip: a micro-millifluidic bioreactor for long-term organoid maintenance
Xue, Y., Seiler, M. J., Tang, W. C., Wang, J. Y., Delgado, J., McLelland, B. T., Nistor, G., Keirstead, H. S., & Browne, A. W. (2021) · Lab on a Chip · doi:10.1039/d1lc00011j · Cited by 71
Metadata
- Authors
- Mattei, G., Giusti, S., & Ahluwalia, A.
- Venue
- Processes
- Publisher
- MDPI AG
- Published
- 2014-07-25
- Volume
- 2
- Issue
- 3
- Pages
- 548-569
- ISSN
- 2227-9717 (ISSN-L)
- OpenAlex
- W2094220307
- Cited by
- 80
- References
- 7
- FWCI
- 2.48
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Design Criteria for Generating Physiologically Relevant In Vitro Models in Bioreactors. https://app.cochat.ai/papers/10.3390/pr2030548
- The paper
- Mattei, G., Giusti, S., & Ahluwalia, A. (2014). Design Criteria for Generating Physiologically Relevant In Vitro Models in Bioreactors. Processes. https://doi.org/10.3390/pr2030548
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.