The DOI matches its Crossref record; 41 of the 41 references it cites were found in a registry or an index.
Recent Advances in Paper-Based Sensors
Open accessAbstract
Paper-based sensors are a new alternative technology for fabricating simple, low-cost, portable and disposable analytical devices for many application areas including clinical diagnosis, food quality control and environmental monitoring. The unique properties of paper which allow passive liquid transport and compatibility with chemicals/biochemicals are the main advantages of using paper as a sensing platform. Depending on the main goal to be achieved in paper-based sensors, the fabrication methods and the analysis techniques can be tuned to fulfill the needs of the end-user. Current paper-based sensors are focused on microfluidic delivery of solution to the detection site whereas more advanced designs involve complex 3-D geometries based on the same microfluidic principles. Although paper-based sensors are very promising, they still suffer from certain limitations such as accuracy and sensitivity. However, it is anticipated that in the future, with advances in fabrication and analytical techniques, that there will be more new and innovative developments in paper-based sensors. These sensors could better meet the current objectives of a viable low-cost and portable device in addition to offering high sensitivity and selectivity, and multiple analyte discrimination. This paper is a review of recent advances in paper-based sensors and covers the following topics: existing fabrication techniques, analytical methods and application areas. Finally, the present challenges and future outlooks are discussed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The origins and the future of microfluidics
Whitesides, G. M. (2006) · Nature · doi:10.1038/nature05058 · Cited by 9,687
Patterned Paper as a Platform for Inexpensive, Low‐Volume, Portable Bioassays
Martinez, A. W., Phillips, S. T., Butte, M. J., & Whitesides, G. M. (2007) · Angewandte Chemie International Edition · doi:10.1002/anie.200603817 · Cited by 2,874
Diagnostics for the Developing World: Microfluidic Paper-Based Analytical Devices
Martinez, A. W., Phillips, S. T., Whitesides, G. M., & Carrilho, E. (2010) · Analytical Chemistry · doi:10.1021/ac9013989 · Cited by 2,674
Understanding Wax Printing: A Simple Micropatterning Process for Paper-Based Microfluidics
Carrilho, E., Martinez, A. W., & Whitesides, G. M. (2009) · Analytical Chemistry · doi:10.1021/ac901071p · Cited by 1,612
Martinez, A. W., Phillips, S. T., Carrilho, E., Thomas, S. W., Sindi, H., & Whitesides, G. M. (2008) · Analytical Chemistry · doi:10.1021/ac800112r · Cited by 1,443
Tobjörk, D., & Österbacka, R. (2011) · Advanced Materials · doi:10.1002/adma.201004692 · Cited by 1,287
Three-dimensional microfluidic devices fabricated in layered paper and tape
Martinez, A. W., Phillips, S. T., & Whitesides, G. M. (2008) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0810903105 · Cited by 1,246
Electrochemical Detection for Paper-Based Microfluidics
Dungchai, W., Chailapakul, O., & Henry, C. S. (2009) · Analytical Chemistry · doi:10.1021/ac9007573 · Cited by 1,224
Microfluidic platforms for lab-on-a-chip applications
Haeberle, S., & Zengerle, R. (2007) · Lab on a Chip · doi:10.1039/b706364b · Cited by 1,124
Electrochemical sensing in paper-based microfluidic devices
Nie, Z., Nijhuis, C. A., Gong, J., Chen, X., Kumachev, A., Martinez, A. W., Narovlyansky, M., & Whitesides, G. M. (2010) · Lab Chip · doi:10.1039/b917150a · Cited by 929
A perspective on paper-based microfluidics: Current status and future trends
Li, X., Ballerini, D. R., & Shen, W. (2012) · Biomicrofluidics · doi:10.1063/1.3687398 · Cited by 813
Inkjet-Printed Microfluidic Multianalyte Chemical Sensing Paper
Abe, K., Suzuki, K., & Citterio, D. (2008) · Analytical Chemistry · doi:10.1021/ac800604v · Cited by 766
Francis, J. S., Doherty, M. C., Lopatin, U., Johnston, C. P., Sinha, G., Ross, T., Cai, M., Hansel, N. N., Perl, T., Ticehurst, J. R., et al. (2005) · Clinical Infectious Diseases · doi:10.1086/427148 · Cited by 719
Low-Cost Printing of Poly(dimethylsiloxane) Barriers To Define Microchannels in Paper
Bruzewicz, D. A., Reches, M., & Whitesides, G. M. (2008) · Analytical Chemistry · doi:10.1021/ac702605a · Cited by 616
Electrogenerated Chemiluminescence Detection in Paper-Based Microfluidic Sensors
Delaney, J. L., Hogan, C. F., Tian, J., & Shen, W. (2011) · Analytical Chemistry · doi:10.1021/ac102392t · Cited by 592
Integration of paper-based microfluidic devices with commercial electrochemical readers
Nie, Z., Deiss, F., Liu, X., Akbulut, O., & Whitesides, G. M. (2010) · Lab on a Chip · doi:10.1039/c0lc00237b · Cited by 481
Flexographically Printed Fluidic Structures in Paper
Olkkonen, J., Lehtinen, K., & Erho, T. (2010) · Analytical Chemistry · doi:10.1021/ac1027066 · Cited by 369
Use of multiple colorimetric indicators for paper-based microfluidic devices
Dungchai, W., Chailapakul, O., & Henry, C. S. (2010) · Analytica Chimica Acta · doi:10.1016/j.aca.2010.06.019 · Cited by 364
Controlled reagent transport in disposable 2D paper networks
Fu, E., Lutz, B., Kauffman, P., & Yager, P. (2010) · Lab on a Chip · doi:10.1039/b919614e · Cited by 363
Programmable diagnostic devices made from paper and tape
Martinez, A. W., Phillips, S. T., Nie, Z., Cheng, C.-M., Carrilho, E., Wiley, B. J., & Whitesides, G. M. (2010) · Lab on a Chip · doi:10.1039/c0lc00021c · Cited by 360
Paper-Based Bioassays Using Gold Nanoparticle Colorimetric Probes
Zhao, W., Ali, M. M., Aguirre, S. D., Brook, M. A., & Li, Y. (2008) · Analytical Chemistry · doi:10.1021/ac801008q · Cited by 338
Yu, J., Ge, L., Huang, J., Wang, S., & Ge, S. (2011) · Lab on a Chip · doi:10.1039/c0lc00524j · Cited by 327
Hossain, S. M. Z., Luckham, R. E., McFadden, M. J., & Brennan, J. D. (2009) · Analytical Chemistry · doi:10.1021/ac901714h · Cited by 316
Transport in two-dimensional paper networks
Fu, E., Ramsey, S. A., Kauffman, P., Lutz, B., & Yager, P. (2011) · Microfluidics and Nanofluidics · doi:10.1007/s10404-010-0643-y · Cited by 313
Point-of-care immunotesting: Approaching the analytical performance of central laboratory methods
von Lode, P. (2005) · Clinical Biochemistry · doi:10.1016/j.clinbiochem.2005.03.008 · Cited by 290
A paper and plastic device for performing recombinase polymerase amplification of HIV DNA
Rohrman, B. A., & Richards-Kortum, R. R. (2012) · Lab on a Chip · doi:10.1039/c2lc40423k · Cited by 273
Wang, L., Chen, W., Xu, D., Shim, B. S., Zhu, Y., Sun, F., Liu, L., Peng, C., Jin, Z., Xu, C., et al. (2009) · Nano Letters · doi:10.1021/nl902368r · Cited by 266
(2008) · Lab on a Chip · doi:10.1039/b814043j · Cited by 235
Paper based point-of-care testing disc for multiplex whole cell bacteria analysis
Li, C.-Z., Vandenberg, K., Prabhulkar, S., Zhu, X., Schneper, L., Methee, K., Rosser, C. J., & Almeide, E. (2011) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2011.04.035 · Cited by 218
Shiroma, L. Y., Santhiago, M., Gobbi, A. L., & Kubota, L. T. (2012) · Analytica Chimica Acta · doi:10.1016/j.aca.2012.03.011 · Cited by 217
Progress in patterned paper sizing for fabrication of paper-based microfluidic sensors
Li, X., Tian, J., & Shen, W. (2010) · Cellulose · doi:10.1007/s10570-010-9401-2 · Cited by 187
Paper surfaces functionalized by nanoparticles
Ngo, Y. H., Li, D., Simon, G. P., & Garnier, G. (2011) · Advances in Colloid and Interface Science · doi:10.1016/j.cis.2011.01.004 · Cited by 179
Semiquantitative Specific Test Paper for Glucose in Urine
Comer, J. P. (1956) · Analytical Chemistry · doi:10.1021/ac60119a030 · Cited by 177
Paper-Based Analytical Device for Electrochemical Flow-Injection Analysis of Glucose in Urine
Lankelma, J., Nie, Z., Carrilho, E., & Whitesides, G. M. (2012) · Analytical Chemistry · doi:10.1021/ac3003648 · Cited by 175
“Fluidic batteries” as low-cost sources of power in paper-based microfluidic devices
Thom, N. K., Yeung, K., Pillion, M. B., & Phillips, S. T. (2012) · Lab on a Chip · doi:10.1039/c2lc40126f · Cited by 161
Quantitative biomarker assay with microfluidic paper-based analytical devices
Xu, L., Tian, J., & Shen, W. (2009) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-009-3195-9 · Cited by 143
Flexible ethanol sensors on glossy paper substrates operating at room temperature
Arena, A., Donato, N., Saitta, G., Bonavita, A., Rizzo, G., & Neri, G. (2009) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2009.12.053 · Cited by 130
Biosurface engineering through ink jet printing
Khan, M. S., Fon, D., Li, X., Tian, J., Forsythe, J. S., Garnier, G., & Shen, W. (2009) · Colloids and Surfaces B Biointerfaces · doi:10.1016/j.colsurfb.2009.09.032 · Cited by 93
DNA circuits as amplifiers for the detection of nucleic acids on a paperfluidic platform
Allen, P. B., Arshad, S. A., Li, B., Chen, X., & Ellington, A. D. (2012) · Lab on a Chip · doi:10.1039/c2lc40373k · Cited by 80
Heterogeneous Films of Ionotropic Hydrogels Fabricated from Delivery Templates of Patterned Paper
Bracher, P. J., Gupta, M., Mack, E. T., & Whitesides, G. M. (2009) · ACS Applied Materials & Interfaces · doi:10.1021/am900340m · Cited by 46
Patterned paper as a template for the delivery of reactants in the fabrication of planar materials
Bracher, P. J., Gupta, M., & Whitesides, G. M. (2010) · Soft Matter · doi:10.1039/c0sm00031k · Cited by 36
Cited by
Paper-based microfluidic point-of-care diagnostic devices
Yetisen, A. K., Akram, M. S., & Lowe, C. R. (2013) · Lab on a Chip · doi:10.1039/c3lc50169h · Cited by 1,943
Technology Roadmap for Flexible Sensors
Luo, Y., Abidian, M. R., Ahn, J.-H., Akinwande, D., Andrews, A. M., Antonietti, M., Bao, Z., Berggren, M., Berkey, C. A., Bettinger, C. J., et al. (2023) · ACS Nano · doi:10.1021/acsnano.2c12606 · Cited by 1,383
Recent Developments in Paper-Based Microfluidic Devices
Cate, D. M., Adkins, J. A., Mettakoonpitak, J., & Henry, C. S. (2015) · Analytical Chemistry · doi:10.1021/ac503968p · Cited by 1,236
Electronic Textiles for Wearable Point-of-Care Systems
Chen, G., Xiao, X., Zhao, X., Tat, T., Bick, M., & Chen, J. (2022) · Chemical Reviews · doi:10.1021/acs.chemrev.1c00502 · Cited by 688
Guide to Selecting a Biorecognition Element for Biosensors
Morales, M. A., & Halpern, J. M. (2018) · Bioconjugate Chemistry · doi:10.1021/acs.bioconjchem.8b00592 · Cited by 539
Metadata
- Authors
- Liana, D. D., Raguse, B., Gooding, J. J., & Chow, E.
- Venue
- Sensors
- Publisher
- MDPI AG
- Published
- 2012-08-24
- Volume
- 12
- Issue
- 9
- Pages
- 11505-11526
- ISSN
- 1424-8220 (ISSN-L)
- OpenAlex
- W2051243774
- Cited by
- 660
- References
- 41
- FWCI
- 21.28
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.