The DOI matches its Crossref record; 76 of the 76 references it cites were found in a registry or an index.
Surface Electromyography Signal Processing and Classification Techniques
Open accessAbstract
Electromyography (EMG) signals are becoming increasingly important in many applications, including clinical/biomedical, prosthesis or rehabilitation devices, human machine interactions, and more. However, noisy EMG signals are the major hurdles to be overcome in order to achieve improved performance in the above applications. Detection, processing and classification analysis in electromyography (EMG) is very desirable because it allows a more standardized and precise evaluation of the neurophysiological, rehabitational and assistive technological findings. This paper reviews two prominent areas; first: the pre-processing method for eliminating possible artifacts via appropriate preparation at the time of recording EMG signals, and second: a brief explanation of the different methods for processing and classifying EMG signals. This study then compares the numerous methods of analyzing EMG signals, in terms of their performance. The crux of this paper is to review the most recent developments and research studies related to the issues mentioned above.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Huang, N. E., Shen, Z., Long, S. R., Wu, M. C., Shih, H. H., Zheng, Q., Yen, N.-C., Tung, C. C., & Liu, H. H. (1998) · Proceedings of the Royal Society of London. Series A: Mathematical, Physical and Engineering Sciences · doi:10.1098/rspa.1998.0193 · Cited by 23,564
An Information-Maximization Approach to Blind Separation and Blind Deconvolution
Bell, A. J., & Sejnowski, T. J. (1995) · Neural Computation · doi:10.1162/neco.1995.7.6.1129 · Cited by 8,986
ENSEMBLE EMPIRICAL MODE DECOMPOSITION: A NOISE-ASSISTED DATA ANALYSIS METHOD
WU, Z., & HUANG, N. E. (2009) · Advances in Adaptive Data Analysis · doi:10.1142/s1793536909000047 · Cited by 8,715
Independent component analysis, A new concept?
Comon, P. (1994) · Signal Processing · doi:10.1016/0165-1684(94)90029-9 · Cited by 8,205
The wavelet transform, time-frequency localization and signal analysis
Daubechies, I. (1990) · IEEE Transactions on Information Theory · doi:10.1109/18.57199 · Cited by 6,483
Fast and robust fixed-point algorithms for independent component analysis
Hyvarinen, A. (1999) · IEEE Transactions on Neural Networks · doi:10.1109/72.761722 · Cited by 6,246
WAVELET TRANSFORMS AND THEIR APPLICATIONS TO TURBULENCE
Farge, M. (1992) · Annual Review of Fluid Mechanics · doi:10.1146/annurev.fl.24.010192.002143 · Cited by 3,062
Blind beamforming for non-gaussian signals
Cardoso, J. F., & Souloumiac, A. (1993) · IEE Proceedings F Radar and Signal Processing · doi:10.1049/ip-f-2.1993.0054 · Cited by 2,738
The Cascade-Correlation learning architecture
Fahlman, S. E., & Lebiere, C. J. (2018) · doi:10.1184/r1/6610403 · Cited by 2,372
A new strategy for multifunction myoelectric control
Hudgins, B., Parker, P., & Scott, R. N. (1993) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.204774 · Cited by 2,149
A robust, real-time control scheme for multifunction myoelectric control
Englehart, K., & Hudgins, B. (2003) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2003.813539 · Cited by 1,743
Techniques of EMG signal analysis: detection, processing, classification and applications
Reaz, M. B. I., Hussain, M. S., & Mohd-Yasin, F. (2006) · Biological Procedures Online · doi:10.1251/bpo115 · Cited by 1,629
Self-citationFeature reduction and selection for EMG signal classification
Phinyomark, A., Phukpattaranont, P., & Limsakul, C. (2012) · Expert Systems with Applications · doi:10.1016/j.eswa.2012.01.102 · Cited by 1,542
Myoelectric control systems—A survey
Asghari Oskoei, M., & Hu, H. (2007) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2007.07.009 · Cited by 1,244
Scheme, E., & Englehart, K. (2011) · The Journal of Rehabilitation Research and Development · doi:10.1682/jrrd.2010.09.0177 · Cited by 969
Navarro, X., Krueger, T. B., Lago, N., Micera, S., Stieglitz, T., & Dario, P. (2005) · Journal of the Peripheral Nervous System · doi:10.1111/j.1085-9489.2005.10303.x · Cited by 845 · cited 1×
“For this reason, they are widely used as surface electrodes [7].”
MethodA wavelet-based continuous classification scheme for multifunction myoelectric control
Englehart, K., Hudgin, B., & Parker, P. A. (2001) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.914793 · Cited by 697 · cited 1×
“Wavelet-based feature set reduced in dimension by principal components analysis greatly improves the classification accuracy in myoelectric-controlled prosthesis applicaion [91].”
BackgroundClassification of the myoelectric signal using time-frequency based representations
Englehart, K., Hudgins, B., Parker, P. A., & Stevenson, M. (1999) · Medical Engineering & Physics · doi:10.1016/s1350-4533(99)00066-1 · Cited by 645
Sampling, noise-reduction and amplitude estimation issues in surface electromyography
Clancy, E. A., Morin, E. L., & Merletti, R. (2002) · Journal of Electromyography and Kinesiology · doi:10.1016/s1050-6411(01)00033-5 · Cited by 634
EMG feature evaluation for movement control of upper extremity prostheses
Zardoshti-Kermani, M., Wheeler, B. C., Badie, K., & Hashemi, R. M. (1995) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/86.481972 · Cited by 477
Modern Techniques in Neuroscience Research
(1999) · Springer eBooks · doi:10.1007/978-3-642-58552-4 · Cited by 452
The effects of electrode impedance on data quality and statistical significance in ERP recordings
Kappenman, E. S., & Luck, S. J. (2010) · Psychophysiology · doi:10.1111/j.1469-8986.2010.01009.x · Cited by 447
Myoelectric Control of Artificial Limbs—Is There a Need to Change Focus? [In the Spotlight]
Jiang, N., Dosen, S., Muller, K.-R., & Farina, D. (2012) · IEEE Signal Processing Magazine · doi:10.1109/msp.2012.2203480 · Cited by 434
Crosstalk in surface electromyography: Theoretical and practical estimates
Winter, D. A., Fuglevand, A. J., & Archer, S. E. (1994) · Journal of Electromyography and Kinesiology · doi:10.1016/1050-6411(94)90023-x · Cited by 390
Fuzzy EMG classification for prosthesis control
Chan, F. H. Y., Yang, Y.-S., Lam, F. K., Zhang, Y.-T., & Parker, P. A. (2000) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/86.867872 · Cited by 376
Chu, J.-U., Moon, I., & Mun, M.-S. (2006) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2006.883695 · Cited by 352
A Review of Non-Invasive Techniques to Detect and Predict Localised Muscle Fatigue
Al-Mulla, M. R., Sepulveda, F., & Colley, M. (2011) · Sensors · doi:10.3390/s110403545 · Cited by 310
Chu, J.-U., Moon, I., Lee, Y.-J., Kim, S.-K., & Mun, M.-S. (2007) · IEEE/ASME Transactions on Mechatronics · doi:10.1109/tmech.2007.897262 · Cited by 299
Online Electromyographic Control of a Robotic Prosthesis
Shenoy, P., Miller, K. J., Crawford, B., & Rao, R. P. N. (2008) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2007.909536 · Cited by 285
Identification of EMG signals using discriminant analysis and SVM classifier
Alkan, A., & Günay, M. (2012) · Expert Systems with Applications · doi:10.1016/j.eswa.2011.06.043 · Cited by 274
Using time-dependent neural networks for EEG classification
Haselsteiner, E., & Pfurtscheller, G. (2000) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/86.895948 · Cited by 240
Application of higher order statistics/spectra in biomedical signals—A review
Chua, K. C., Chandran, V., Acharya, U. R., & Lim, C. M. (2010) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2010.04.009 · Cited by 233
Removing ECG noise from surface EMG signals using adaptive filtering
Lu, G., Brittain, J.-S., Holland, P., Yianni, J., Green, A. L., Stein, J. F., Aziz, T. Z., & Wang, S. (2009) · Neuroscience Letters · doi:10.1016/j.neulet.2009.06.063 · Cited by 222
Minimizing Electrode Motion Artifact by Skin Abrasion
Tam, H., & Webster, J. G. (1977) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1977.326117 · Cited by 220
Classification of EMG signals using wavelet neural network
Subasi, A., Yilmaz, M., & Ozcalik, H. R. (2006) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2006.03.004 · Cited by 211
Hargrove, L. J., Li, G., Englehart, K. B., & Hudgins, B. S. (2009) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2008.2008171 · Cited by 211
Surface EMG: The issue of electrode location
Mesin, L., Merletti, R., & Rainoldi, A. (2009) · Journal of Electromyography and Kinesiology · doi:10.1016/j.jelekin.2008.07.006 · Cited by 200
The effect of subcutaneous fat on myoelectric signal amplitude and cross-talk
Kuiken, T. A., Lowery, M. M., & Stoykov, N. S. (2003) · Prosthetics & Orthotics International · doi:10.3109/03093640309167976 · Cited by 196
EMG signal filtering based on Empirical Mode Decomposition
Andrade, A. O., Nasuto, S., Kyberd, P., Sweeney-Reed, C. M., & Van Kanijn, F. R. (2006) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2006.03.003 · Cited by 196
Wavelet basis functions in biomedical signal processing
Rafiee, J., Reif, J., Prause, N., & Schoen, M. P. (2011) · Expert Systems with Applications · doi:10.1016/j.eswa.2010.11.050 · Cited by 183
Surface electromyography: Why, when and how to use it
Garcia, M. A. C., & Vieira, T. (2011) · PORTO@Iris · Cited by 182
Wavelet analysis of surface electromyography
Kumar, D., Pah, N. D., & Bradley, A. (2003) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2003.819901 · Cited by 180
Accessing the Neural Drive to Muscle and Translation to Neurorehabilitation Technologies
Farina, D., & Negro, F. (2012) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2012.2183586 · Cited by 160
A Neuro–Fuzzy Inference System for sEMG-Based Identification of Hand Motion Commands
Khezri, M., & Jahed, M. (2010) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2010.2053334 · Cited by 160
Kanosue, K., Yoshida, M., Akazawa, K., & FUJII, K. (1979) · The Japanese Journal of Physiology · doi:10.2170/jjphysiol.29.427 · Cited by 153
Merletti, R., Indino, B., Graven‐Nielsen, T., & Farina, D. (2004) · Methods of Information in Medicine · doi:10.1055/s-0038-1633419 · Cited by 136
Acquisition, Processing and Analysis of the Surface Electromyogram
Gerdle, B. U. C., Karlsson, S. J., Day, S. J., & Djupsjöbacka, M. (1999) · Springer eBooks · doi:10.1007/978-3-642-58552-4_26 · Cited by 133
Reducing skin potential motion artefact by skin abrasion
Burbank, D. P., & Webster, J. G. (1978) · Medical & Biological Engineering & Computing · doi:10.1007/bf02442929 · Cited by 130
Recognition of Electromyographic Signals Using Cascaded Kernel Learning Machine
Liu, Y., Huang, H., & Weng, C.-H. (2007) · IEEE/ASME Transactions on Mechatronics · doi:10.1109/tmech.2007.897253 · Cited by 121
A simulation study to examine the use of cross-correlation as an estimate of surface EMG cross talk
Lowery, M. M., Stoykov, N. S., & Kuiken, T. (2003) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00698.2002 · Cited by 120
Willigenburg, N. W., Daffertshofer, A., Kingma, I., & van Dieën, J. H. (2012) · Journal of Electromyography and Kinesiology · doi:10.1016/j.jelekin.2012.01.001 · Cited by 120
Nakamura, H., Yoshida, M., Kotani, M., Akazawa, K., & Moritani, T. (2004) · Journal of Electromyography and Kinesiology · doi:10.1016/j.jelekin.2004.01.004 · Cited by 107
Time-scale analysis of motor unit action potentials
Pattichis, C. S., & Pattichis, M. S. (1999) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.797992 · Cited by 105
Filtering of surface EMG using ensemble empirical mode decomposition
Zhang, X., & Zhou, P. (2012) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2012.10.009 · Cited by 101
An automated ECG-artifact removal method for trunk muscle surface EMG recordings
Mak, J. N., Hu, Y. S., & Luk, K. D. K. (2010) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2010.05.007 · Cited by 74
Phinyomark, A., Hu, H., Phukpattaranont, P., & Limsakul, C. (2012) · Measurement Science Review · doi:10.2478/v10048-012-0015-8 · Cited by 71
Independent Component Analysis of High-Density Electromyography in Muscle Force Estimation
Staudenmann, D., Daffertshofer, A., Kingma, I., Stegeman, D. F., & van Dieën, J. H. (2007) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2006.889202 · Cited by 59
A decomposition algorithm for surface electrode-array electromyogram
García, G. A., Okuno, R., & Azakawa, K. (2005) · IEEE Engineering in Medicine and Biology Magazine · doi:10.1109/memb.2005.1463398 · Cited by 58
EMG-Based Motion Discrimination Using a Novel Recurrent Neural Network
Bu, N., Fukuda, O., & Tsuji, T. (2003) · Journal of Intelligent Information Systems · doi:10.1023/a:1024706431807 · Cited by 56
A Comparative Study of Wavelet Denoising of Surface Electromyographic Signals
Jiang, C., & Kuo, S.-L. (2007) · Conference proceedings · doi:10.1109/iembs.2007.4352679 · Cited by 54
Multi run ICA and surface EMG based signal processing system for recognising hand gestures
Naik, G. R., Kumar, D., & Palaniswami, M. S. (2008) · IEEE International Conference on Computer and Information Technology (CIT) · doi:10.1109/cit.2008.4594760 · Cited by 49
Hargrove, L. J., Zhou, P., Englehart, K. B., & Kuiken, T. (2008) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2008.2010392 · Cited by 49
Hemingway, M. A., Biedermann, H.-J., & Inglis, J. (1995) · Applied Psychophysiology and Biofeedback · doi:10.1007/bf01712765 · Cited by 48
Tsuji, T., Ichinobe, H., Ito, K., & Nagamachi, M. (1993) · Transactions of the Society of Instrument and Control Engineers · doi:10.9746/sicetr1965.29.1213 · Cited by 44
Use of Support Vector Machines and Neural Network in Diagnosis of Neuromuscular Disorders
Güler, N. F., & Koçer, S. (2005) · Journal of Medical Systems · doi:10.1007/s10916-005-5187-4 · Cited by 43
Intelligent Noise Removal from EMG Signal Using Focused Time-Lagged Recurrent Neural Network
Kale, S. N., & Dudul, S. V. (2009) · Applied Computational Intelligence and Soft Computing · doi:10.1155/2009/129761 · Cited by 40
Continuous wavelet transform application to EMG signals during human gait
Ismail, A., & ASFOUR, S. S. (2002) · Asilomar Conference on Signals, Systems and Computers (ACSSC) · doi:10.1109/acssc.1998.750880 · Cited by 37
Hussain, M., & Reaz, M. B. I. (2012) · Measurement Science Review · doi:10.2478/v10048-012-0005-x · Cited by 35
Self-citationMan-Machine Interface System for Neuromuscular Training and Evaluation Based on EMG and MMG Signals
de la Rosa, R., Alonso, A., Carrera, A., Barroso, R. J. D., & Fernández, P. (2010) · Sensors · doi:10.3390/s101211100 · Cited by 29
Surface Electromyogram signal estimation based on wavelet thresholding technique
Khezri, M., & Jahed, M. (2008) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2008.4650275 · Cited by 28
Nakamura, H., Yoshida, M., Kotani, M., et al. (2004) · Journal of Electromyography and Kinesiology · doi:10.1016/j.jelekin.2004.01.005 · Cited by 27
Intelligent Systems and Technologies in Rehabilitation Engineering
(2000) · CRC Press eBooks · doi:10.1201/9780367801816 · Cited by 23
A comparison of ICA algorithms in surface EMG signal processing
Naik, G. R. (2011) · International Journal of Biomedical Engineering and Technology · doi:10.1504/ijbet.2011.041774 · Cited by 21
Taelman, J., Mijović, B., Huffel, S. V., et al. (2011) · International Conference on Bio-inspired Systems and Signal Processing · doi:10.5220/0003136804210424 · Cited by 20
Ito, K., Tsuji, T., Kato, A., & Itō, M. (1991) · International Joint Conference on Neural Networks (IJCNN) · doi:10.1109/ijcnn.1991.170562 · Cited by 19
EMG motion pattern classification through design and optimization of Neural Network
Ahsan, M. R., Ibrahimy, M. I., & Khalifa, O. O. (2012) · doi:10.1109/icobe.2012.6179000 · Cited by 16
Cited by
Bi, L., Feleke, A. >., & Guan, C. (2019) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2019.02.011 · Cited by 418
Tian, L., Zimmerman, B., Akhtar, A., Yu, K. J., Moore, M., Wu, J., Larsen, R. J., Lee, J. W., Li, J., Liu, Y., et al. (2019) · Nature Biomedical Engineering · doi:10.1038/s41551-019-0347-x · Cited by 393
A Review of Classification Techniques of EMG Signals during Isotonic and Isometric Contractions
Nazmi, N., Abdul Rahman, M., Yamamoto, S.-I., Ahmad, S., Zamzuri, H., & Mazlan, S. (2016) · Sensors · doi:10.3390/s16081304 · Cited by 377
Surface EMG-Based Inter-Session Gesture Recognition Enhanced by Deep Domain Adaptation
Du, Y., Jin, W., Wei, W., Hu, Y., & Geng, W. (2017) · Sensors · doi:10.3390/s17030458 · Cited by 363
Current Status of Neuromuscular Reversal and Monitoring: Challenges and Opportunities
Brull, S. J., & Kopman, A. F. (2017) · Anesthesiology · doi:10.1097/aln.0000000000001409 · Cited by 280
Metadata
- Authors
- Chowdhury, R., Reaz, M., Ali, M., Bakar, A., Chellappan, K., & Chang, T.
- Venue
- Sensors
- Publisher
- MDPI AG
- Published
- 2013-09-17
- Volume
- 13
- Issue
- 9
- Pages
- 12431-12466
- ISSN
- 1424-8220 (ISSN-L)
- OpenAlex
- W2002499457
- Cited by
- 1,000
- References
- 76
- FWCI
- 16.83
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.