CoChat

Nyquist Zone Index and Chirp Rate Estimation of LFM Signal Intercepted by Nyquist Folding Receiver Based on Random Sample Consensus and Fractional Fourier Transform

Open access

The DOI matches its Crossref record; 29 of the 30 references it cites were found in a registry or an index; 1 of the 13 sources its claims cite were checked for support.

Abstract

The Nyquist folding receiver (NYFR) can achieve a high-probability interception of an ultra-wideband (UWB) signal with fewer devices, while the output of the NYFR is converted into a hybrid modulated signal of the local oscillator (LO) and the received signal, which requires the matching parameter estimation methods. The linear frequency modulation (LFM) signal is a typical low probability of intercept (LPI) radar signal. In this paper, an estimation method of both the Nyquist Zone (NZ) index and the chirp rate for the LFM signal intercepted by NYFR was proposed. First, according to the time-frequency characteristics of the LFM signal, the accurate NZ and the rough chirp rate was estimated based on least squares (LS) and random sample consensus (RANSAC). Then, the information of the LO was removed from the hybrid modulated signal by the known NZ, and the precise chirp rate was obtained by using the fractional Fourier transform (FrFT). Moreover, a fast search method of FrFT optimal order was presented, which could obviously reduce the computational complexity. The simulation demonstrated that the proposed method could precisely estimate the parameters of the hybrid modulated output signal of the NYFR.

Overview

CoChat Summary

TL;DR

This paper proposes a two-stage method using RANSAC and fractional Fourier transform (FrFT) to estimate the Nyquist Zone (NZ) index and chirp rate of an LFM signal intercepted by a Nyquist folding receiver (NYFR). Simulations show accurate NZ determination and chirp-rate estimation, with NZ correct probability >90% for SNR ≥ −9 dB and 100% for SNR ≥ −7 dB.

Key findings

  • The proposed RANSAC + FrFT method estimated the NZ index with probability >90% when SNR ≥ −9 dB and 100% when SNR ≥ −7 dB; chirp-rate estimation was stable when SNR ≥ −8 dB.
  • In the worked example, the true LFM had starting frequency 7.65 GHz in the 4th NZ, folded to −0.35 GHz, and chirp rate 6×10^14 Hz/s. RANSAC gave intercept −0.35037 GHz and chirp rate 5.9897×10^14 Hz/s; FrFT gave 6.002×10^14 Hz/s.
  • The NZ estimate used Δf = 0.18845 GHz with mf = 2.5 and fsin = 10 MHz, yielding m̂ = 3.7691, whose ceiling correctly gave the 4th NZ.
  • The fast FrFT order search increased accuracy exponentially with approximation order while processing time grew only linearly; required accuracy was generally obtained at the 2nd or 3rd order. The method failed below about −9 dB SNR.

Methods

  • The NYFR output for an LFM input is modeled as an LFM/SFM hybrid modulated signal. STFT time–frequency characteristic points are extracted at peaks and valleys, then upper and lower boundaries are fitted using LS and RANSAC.
  • The longitudinal interval between fitted boundaries estimates the SFM modulation bandwidth and thus the NZ index via m̂ = Δf/(2mf fsin), taking the ceiling. The center line gives rough chirp rate and starting frequency.
  • After removing the LO-dependent SFM using the estimated NZ, FrFT estimates the precise chirp rate. A stepwise-refinement fast search finds the optimal FrFT order starting from the RANSAC rough estimate. Monte Carlo simulations used 200 runs per SNR and compared PCD for NZ and NRMSE of chirp rate against spectrum peak search, autocorrelation, and QMFB methods.

Limitations

  • The paper states that it assumed the received signal contained only a single LFM and that the LFM frequency range did not cross NZ junctions; processing of multiple signals in NYFR is left for further study.
  • The paper states that the peak-search-based method fails when SNR is below about −9 dB because the peak is submerged in noise.
  • The text makes evident that RANSAC alone does not use all sampling points and its frequency resolution is limited by the STFT window length; the autocorrelation comparison method is interval-dependent and not suitable for short pulses less than an LO frequency modulation period. Evaluation is simulation-based, with no hardware experimental validation reported.

Model-written summary. Check it against the paper before relying on it.

Integrity signals

Registry

Crossref · 10.3390/s19061477

Cites

29 of 29 references verified0 citation errors · 0 not checkable

Statistics

Nothing to recompute.

Figures

Figure 1 Nyquist folding receiver (NYFR) architecture.
Figure 1 Nyquist folding receiver (NYFR) architecture.CC BY · PubMed Central
Figure 2 The relationship between m (or Nyquist Zone (NZ)) and frequency.
Figure 2 The relationship between m (or Nyquist Zone (NZ)) and frequency.CC BY · PubMed Central
Figure 3 Time–frequency diagram of a linear frequency modulation (LFM) signal intercepted by NYFR.
Figure 3 Time–frequency diagram of a linear frequency modulation (LFM) signal intercepted by NYFR.CC BY · PubMed Central
Figure 4 The upper and lower bounds of LFM/sinusoidal frequency modulation (SFM) hybrid modulated signal.
Figure 4 The upper and lower bounds of LFM/sinusoidal frequency modulation (SFM) hybrid modulated signal.CC BY · PubMed Central
Figure 5 The obtained upper and lower bounds of LFM/SFM hybrid modulated signal by least squares (LS) when signal-to-noise ratio (SNR) = −5 dB.
Figure 5 The obtained upper and lower bounds of LFM/SFM hybrid modulated signal by least squares (LS) when signal-to-noise ratio (SNR) = −5 dB.CC BY · PubMed Central
Figure 6 The obtained upper and lower bounds of LFM/SFM hybrid modulated signal by random sample consensus (RANSAC) when SNR = −5 dB.
Figure 6 The obtained upper and lower bounds of LFM/SFM hybrid modulated signal by random sample consensus (RANSAC) when SNR = −5 dB.CC BY · PubMed Central
Figure 7 The obtained LFM time–frequency representation through upper and lower bounds when SNR =−5 dB.
Figure 7 The obtained LFM time–frequency representation through upper and lower bounds when SNR =−5 dB.CC BY · PubMed Central
Figure 8 The schematic of the fractional Fourier transform (FrFT) principle.
Figure 8 The schematic of the fractional Fourier transform (FrFT) principle.CC BY · PubMed Central
Figure 9 FrFT output with different FrFT orders when SNR = −5 dB.
Figure 9 FrFT output with different FrFT orders when SNR = −5 dB.CC BY · PubMed Central
Figure 10 Fitting effect of random sample consensus (RANSAC) when the local oscillator (LO) is LFM.
Figure 10 Fitting effect of random sample consensus (RANSAC) when the local oscillator (LO) is LFM.CC BY · PubMed Central
Figure 11 FrFT output with different FrFT orders when the LO is LFM.
Figure 11 FrFT output with different FrFT orders when the LO is LFM.CC BY · PubMed Central
Figure 12 Probabilities of correct NZ determination obtained by considered methods with different SNRs.
Figure 12 Probabilities of correct NZ determination obtained by considered methods with different SNRs.CC BY · PubMed Central
Figure 13 Normalized root mean square error (NRMSE) of chirp rate estimation.
Figure 13 Normalized root mean square error (NRMSE) of chirp rate estimation.CC BY · PubMed Central

Verification

Claims the paper makes

1 Valid · 2 Not valid · 9 Not checked · 38 Own results and interpretations

29 more claims

Create a free account to see all 50 claims and every source verdict.

See all claims — free account
  • The quote only partly states this claim. 1
  • It may state two separate claims as one. 14
  • Probably not a substantial claim. 2

Create a free account to see these claims.

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

Each contradiction between two passages listed here was confirmed by an independent check.

1 of 1

Citations

Cites

Cited by

See all 8

Metadata

Authors
Liu, X., Li, T., Fan, X., & Chen, Z.
Affiliations
  • National University of Defense Technology (CN)
  • Artificial Intelligence Research Center (AIRC), National Innovation Institute of Defense Technology (NIIDT), NO.2 Fengtai South Road, Fengtai District, Beijing 100071, China
Corresponding author
Li, Tao
Venue
Sensors
Publisher
MDPI AG
Published
2019-03-26
Volume
19
Issue
6
Pages
1477
ISSN
1424-8220 (ISSN-L)
OpenAlex
W2924508530
Cited by
8
References
30
Citations by year
2025: 1 · 2023: 1 · 2022: 1 · 2021: 3 · 2020: 2
FWCI
1.10
Type
journal article
Language
en
Open access
Locations
  • Sensors (publishedVersion, cc-by)
  • Europe PMC (PubMed Central) (publishedVersion, cc-by)
  • PubMed Central (publishedVersion, cc-by)
  • PubMed (publishedVersion)
  • DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
Topics
  • Physical Sciences › Engineering › Aerospace Engineering › Radar Systems and Signal Processing
  • Physical Sciences › Engineering › Aerospace Engineering › Advanced SAR Imaging Techniques
  • Physical Sciences › Mathematics › Applied Mathematics › Mathematical Analysis and Transform Methods
Keywords
linear frequency modulation signals, chirp rate estimation, low probability of intercept radar, RANSAC, fractional Fourier transform, parameter estimation

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

The claim verdicts this report counts are experimental: their accuracy is not yet measured.

A language model drew the claims from the paper on 2026-10-10, under version 3 of the claim definition (model deepseek-v4.1-flash, prompt extract-v3).

A second model labelled each claim on 2026-10-10 (model jev-1.13-20260917, definition revision gold-guideline-v0.2).

Cited sources are checked with a language model’s help (gpt-6-sol).

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.