CoChat

Pilot Study of the EncephaLog Smartphone Application for Gait Analysis

Open access
Tchelet, Keren, Stark-Inbar, Alit, Yekutieli, Ziv · 2019 · Sensors

The DOI matches its Crossref record; 47 of the 48 references it cites were found in a registry or an index.

Abstract

Gait disorders and falls are common in elders and in many clinical conditions, yet they are typically infrequently and subjectively evaluated, limiting prevention and intervention. Completion-time of the Timed-Up-and-Go (TUG) test is a well-accepted clinical biomarker for rating mobility and prediction of falls risk. Using smartphones’ integral accelerometers and gyroscopes, we already demonstrated that TUG completion-time can be accurately measured via a smartphone app. Here we present an extended app, EncephaLogTM, which provides gait analysis in much more detail, offering 9 additional gait biomarkers on top of the TUG completion-time. In this pilot, four healthy adults participated in a total of 32 TUG tests; simultaneously recorded by EncephaLog and motion sensor devices used in movement labs: motion capture cameras (MCC), pressure mat; and/or wearable sensors. Results show high agreement between EncephaLog biomarkers and those measured by the other devices. These preliminary results suggest that EncephaLog can provide an accurate, yet simpler, instrumented TUG (iTUG) platform than existing alternatives, offering a solution for clinics that cannot afford the cost or space required for a dedicated motion lab and for monitoring patients at their homes. Further research on a larger study population with pathologies is required to assess full validity.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.3390/s19235179

Cites

47 of 47 references verified0 citation errors · 0 not checkable

Statistics

Figures

Figure A1 MCC data analysis. MCC signals are composed from multiple sensors. Top: An example of MCC “SI signal” composed from data of 3 infrared markers (sternum SI, left shoulder SI, right shoulder SI, marked in cyan, red, and orange lines, respectively) combined in order to obtain one full SI signal that was used in this study. Bottom: Equivalent data from EncephaLog is captured by a single sensor (gyro ML, marked in blue). Shaded backgrounds represent the five TUG phases detected offline, as in Figure 1.
Figure A1 MCC data analysis. MCC signals are composed from multiple sensors. Top: An example of MCC “SI signal” composed from data of 3 infrared markers (sternum SI, left shoulder SI, right shoulder SI, marked in cyan, red, and orange lines, respectively) combined in order to obtain one full SI signal that was used in this study. Bottom: Equivalent data from EncephaLog is captured by a single sensor (gyro ML, marked in blue). Shaded backgrounds represent the five TUG phases detected offline, as in Figure 1.CC BY · PubMed Central
Figure A2 Examples for Opal (a) vs. EncephaLog (b) Raw Signals Correlation. Results from two different walking patterns.
Figure A2 Examples for Opal (a) vs. EncephaLog (b) Raw Signals Correlation. Results from two different walking patterns.CC BY · PubMed Central
Figure 1 Timed-Up-and-Go (TUG) conventions. (A) Human coordinate system. Anterior-Posterior (AP) is the walking direction. (B) Event detection in EncephaLog TUG. Example of EncephaLog data from one TUG test, including nine raw signals collected by a smartphone device (lines), and the five TUG phases detected offline (shaded backgrounds). See Table A1 for events and biomarkers definitions.
Figure 1 Timed-Up-and-Go (TUG) conventions. (A) Human coordinate system. Anterior-Posterior (AP) is the walking direction. (B) Event detection in EncephaLog TUG. Example of EncephaLog data from one TUG test, including nine raw signals collected by a smartphone device (lines), and the five TUG phases detected offline (shaded backgrounds). See Table A1 for events and biomarkers definitions.CC BY · PubMed Central
Figure 2 TUG experimental setups. (A) Experiment 1. The motion capture cameras (MCC) setup included a system of 10 (six drawn for simplicity) motion capture cameras, and eight passive infrared sensors placed on the subject’s body (only seven displayed since the eighth was located on the subject’s back). Additionally, two smartphones devices (Android and iPhone) running EncephaLog were strapped to the subject’s sternum. (B) Experiments 2 and 3. Two smartphones devices (Android and iPhone) running EncephaLog and one wearable sensor (Opal) were strapped to the subject’s sternum, while he/she walked on a pressure walkway mat.
Figure 2 TUG experimental setups. (A) Experiment 1. The motion capture cameras (MCC) setup included a system of 10 (six drawn for simplicity) motion capture cameras, and eight passive infrared sensors placed on the subject’s body (only seven displayed since the eighth was located on the subject’s back). Additionally, two smartphones devices (Android and iPhone) running EncephaLog were strapped to the subject’s sternum. (B) Experiments 2 and 3. Two smartphones devices (Android and iPhone) running EncephaLog and one wearable sensor (Opal) were strapped to the subject’s sternum, while he/she walked on a pressure walkway mat.CC BY · PubMed Central
Figure 3 MCC results. (A) Example of a visual comparison of MCC (top) and EncephaLog (bottom) signals. Note the similarity in the number and duration of steps during TUG Walk Away (WA) and Walk Back phases (WB), despite the different recourses: Superior-Inferior (SI) coordinates in 3D space in the MCC, and acceleration-SI in EncephaLog. (B) Bland–Altman plot, reflecting the degree of agreement between MCC and EncephaLog for TUG Completion Time (n = 17 samples). Presented here is data from an Android (blue) and iOS (green) devices. Dashed lines represent 95% confidence intervals of Bland–Altman (B&A) for Android (magenta) and iOS (red). Similar results and graphs were obtained for all biomarkers in this experiment.
Figure 3 MCC results. (A) Example of a visual comparison of MCC (top) and EncephaLog (bottom) signals. Note the similarity in the number and duration of steps during TUG Walk Away (WA) and Walk Back phases (WB), despite the different recourses: Superior-Inferior (SI) coordinates in 3D space in the MCC, and acceleration-SI in EncephaLog. (B) Bland–Altman plot, reflecting the degree of agreement between MCC and EncephaLog for TUG Completion Time (n = 17 samples). Presented here is data from an Android (blue) and iOS (green) devices. Dashed lines represent 95% confidence intervals of Bland–Altman (B&A) for Android (magenta) and iOS (red). Similar results and graphs were obtained for all biomarkers in this experiment.CC BY · PubMed Central
Figure 4 Pressure mat results. (A) Example of a visual comparison of pressure mat (bottom) and EncephaLog signals (top). Note the similar walking patterns captured simultaneously by both methods. (B) B&A plot, an agreement measurement for Average Steps Frequency between pressure mat and EncephaLog (n = 15 samples), performed on Android (blue) and iOS (green) devices.
Figure 4 Pressure mat results. (A) Example of a visual comparison of pressure mat (bottom) and EncephaLog signals (top). Note the similar walking patterns captured simultaneously by both methods. (B) B&A plot, an agreement measurement for Average Steps Frequency between pressure mat and EncephaLog (n = 15 samples), performed on Android (blue) and iOS (green) devices.CC BY · PubMed Central
Figure 5 Wearable sensor results. (A) Comparison between EncephaLog and Opal WS of linear and angular accelerations. Correlation coefficient (R) and Normalized Root Mean Square Error (NRMSE) between signals of the two methods are presented above each graph. (B) B&A plot, an agreement measurement of Average Step Length between Opal and EncephaLog (n = 15 samples) performed on Android (blue) and iOS (green) devices.
Figure 5 Wearable sensor results. (A) Comparison between EncephaLog and Opal WS of linear and angular accelerations. Correlation coefficient (R) and Normalized Root Mean Square Error (NRMSE) between signals of the two methods are presented above each graph. (B) B&A plot, an agreement measurement of Average Step Length between Opal and EncephaLog (n = 15 samples) performed on Android (blue) and iOS (green) devices.CC BY · PubMed Central

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Research works printed but not linked: 1

  1. Jovanov E. Frith K.H. Madhushri P. Hunter A. Coffey S.S. Milenkovic A. Chapter 44 - Gender Differences in Mobility of Elderly: Measurements and Interventions to Improve Mobility Principles of Gender-Specific Medicine 3rd ed. Legato M.J. Academic Press San Diego, CA, USA 2017 639 653 978-0-12-803506-1

Cited by

See all 29

Metadata

Authors
Tchelet, K., Stark-Inbar, A., & Yekutieli, Z.
Affiliations
Montfort Brain Monitor LTD, Ha-Nasi 14, Zichron Ya’acov 3090314, Israel
Corresponding author
Yekutieli, Ziv
Venue
Sensors
Publisher
MDPI AG
Published
2019-11-26
Volume
19
Issue
23
Pages
5179
ISSN
1424-8220 (ISSN-L)
OpenAlex
W2990605185
Cited by
27
References
48
Citations by year
2025: 6 · 2024: 3 · 2023: 6 · 2022: 8 · 2021: 2 · 2020: 2
FWCI
6.89
Type
journal article
Language
en
Open access
Locations
  • Sensors (publishedVersion, cc-by)
  • PubMed Central (publishedVersion, cc-by)
  • PubMed (publishedVersion)
  • Zenodo (CERN European Organization for Nuclear Research) (submittedVersion, cc-by)
Funders
  • Israeli Innovation Authority (65957)
  • European Commission H2020-MSCA-IF-2016 (753071)
  • Ministry of Aliyah and Integration, Israel (The Center for Integration in Science)
Topics
  • Health Sciences › Health Professions › Physical Therapy, Sports Therapy and Rehabilitation › Balance, Gait, and Falls Prevention
  • Physical Sciences › Computer Science › Computer Vision and Pattern Recognition › Context-Aware Activity Recognition Systems
  • Physical Sciences › Engineering › Biomedical Engineering › Gait Recognition and Analysis
Keywords
mobile application, gait analysis, Timed Up and Go test, gait biomarkers, accelerometer, gyroscope, fall risk, mobility assessment, home monitoring, motion capture comparison, wearable sensors, pressure mat
MeSH terms
Accidental Falls, Smartphone, Gait Analysis, Adult, Female, Gait, Humans, Male, Monitoring, Physiologic, Movement, Pilot Projects

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.