Investigation of Indoor Air Quality and the Identification of Influential Factors at Primary Schools in the North of China
Open accessAbstract
Indoor air quality in four naturally ventilated schools was influenced by building defects and occupants' activities; indoor particulate concentrations could exceed outdoor levels during occupied periods.
Overview
CoChat Summary
TL;DR
In four naturally ventilated primary schools in Tai’an, North China, winter indoor PM2.5, PM10, CO2, and temperature mostly failed IAQ and comfort standards. Building air tightness and occupant activities strongly influenced indoor PM and CO2, with tighter buildings reducing particle penetration but closed windows raising CO2.
Key findings
- Occupied classrooms had mean PM2.5 concentrations of 149–199 µg/m³ and mean PM10 concentrations of 138–205 µg/m³, about 5 times higher than WHO and Chinese standard requirements; the highest PM2.5 was 274 µg/m³ in School D, and the highest PM10 was 267 µg/m³ in School C.
- In unoccupied classrooms, School B had the lowest indoor/outdoor ratios (0.49 for PM2.5, 0.47 for PM10), while School C had the highest (0.85 for PM2.5, 0.9 for PM10); Schools A and D, both air tightness level 4, had I/O ratios around 0.54–0.69.
- Occupied CO2 means all exceeded the WHO 600 ppm and China 1000 ppm limits, ranging from 1237 to 1932 ppm; the highest reading was 4692 ppm in School B, and CO2 dropped to around 500–700 ppm during lunch breaks.
- Only School B met the CIBSE thermal comfort range of 19–21 °C; mean indoor air temperatures ranged from 11.5 °C to 19.4 °C, with School C performing worst.
Methods
- Four naturally ventilated primary schools in Tai’an city, North China, built at different times under different building codes, were selected as case studies; classrooms had similar floor area, floor height, and student numbers.
- Field measurements ran from 20 November to 10 December 2016, 8:00 a.m. to 5:00 p.m., with windows closed; equipment was placed 1.5 m above the floor at classroom centers. PM2.5 and PM10, CO2, and indoor air temperature were measured, plus outdoor PM and weekend unoccupied measurements after cleaning.
- Indoor PM was measured with a BRAMC-SMART-126 detector, outdoor PM with a DUST TRAK model 8530, and temperature/CO2 with an HTV-M detector; results were compared with China GBT18883-2002, WHO, and CIBSE guideline values.
Limitations
- The paper states that due to limited time and resources, only four primary schools were selected and investigations were carried out over three weeks; it argues these cases represent most local primary schools because of standardized school design.
- The paper identifies future research needs: more school buildings, seasonal effects on indoor air quality, penetrability of different particle sizes, and effects of crack distribution in building envelopes.
- Evident from the text: measurements were winter-only, the sample was small, and PM2.5 and PM10 could not be measured simultaneously because the DUST TRAK model 8530 cannot measure both at once, so PM2.5 was measured in the morning and PM10 in the afternoon.
Model-written summary. Check it against the paper before relying on it.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
5 Valid · 2 Not valid · 16 Not checked · 64 Own results and interpretations
The cited sources that could be checked couldn’t confirm or dispute this claim.
In the paper
“Over 70% of a pupil's school life is spent inside a classroom”
- Also stated in: § 1. Introduction · plain
“Bakó-Biró et al. [18] figured out that over 30% of a pupil's life was spent at schools, and about 70% of their time inside a classroom during school days.”
§ Investigation of Indoor Air Quality and the Identification of Influential Factors at Primary Schools in the North of China > Abstract
What the sources say
- Could not verifycites [18] Wargocki, 2004, Effects of pollution from personal computers on perceived air quality, SBS symptoms and productivity in offices, Indoor Air sourceExperimental — accuracy not yet measured
The Introduction discusses how much of employees’ working time involves PCs, and the Approach describes an office experiment with adult subjects. Searches for pupils, classrooms, and the 70% figure found no passage about how pupils spend their school time. The cited paper therefore does not verify this claim. (LLM, conf=0.75)
plain- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Also stated in: § 1. Introduction · plain
A result the paper states — it cites no source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“In addition, indoor comfort is not satisfied in most of the schools investigated.”
§ Investigation of Indoor Air Quality and the Identification of Influential Factors at Primary Schools in the North of China > 4. Discussion
plain- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
A result the paper reports from its own data — it cites no other source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“From Table 5 it can be seen that the schools cannot meet the requirement of thermal comfort based on the recommended values of 19 • C to 21 • C from CIBSE, except School B.”
§ Investigation of Indoor Air Quality and the Identification of Influential Factors at Primary Schools in the North of China > 3.2. Temperature
plain- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: unclear — It is unclear whether the paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
A result the paper reports from its own data — it cites no other source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“The mean values range from 1237 ppm to 1932 ppm.”
§ Investigation of Indoor Air Quality and the Identification of Influential Factors at Primary Schools in the North of China > 3.3. CO 2
plain- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: unclear — It is unclear whether the paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
A result the paper reports from its own data — it cites no other source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“All of the indoor mean values of PM 2.5 are above the annual standard and the 24 h guideline values of the WHO and the GBT18883-2002 of China.”
§ Investigation of Indoor Air Quality and the Identification of Influential Factors at Primary Schools in the North of China > 3.1. PM 2.5 and PM 10
plain- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
24 more claims
Create a free account to see all 87 claims and to verify the 2 references still open.
- Probably not a substantial claim. 31
- It may state two separate claims as one. 39
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
Rated major: it would touch a result — a value a result rests on, reported and recomputed p-values on opposite sides of the significance level, two passages that conflict with no sign which is right, or a cited work retracted before this paper was published.
In the paper
“The average indoor PM 2.5 and PM 10 concentrations in occupied classrooms range from 199 µg/m 3 to 149 µg/m 3 and 205 µg/m 3 to 138 µg/m 3 , respectively, which is 5 times higher than the requirements of the WHO's and China's standards.”
§ Investigation of Indoor Air Quality and the Identification of Influential Factors at Primary Schools in the North of China > 3.1. PM 2.5 and PM 10
Reported 5 · recomputed 2.76
Rated minor: it would not touch a result — a value no result rests on, a p-value that stays on the same side of the significance level, or a conflict that is clerical, resolved elsewhere in the paper, or outside its own findings.
In the paper
“the results indicated that 33% of the samples had a CO 2 concentration above 1700 ppm, which is two times greater than the CIBSE value.”
§ Investigation of Indoor Air Quality and the Identification of Influential Factors at Primary Schools in the North of China > 1. Introduction
Reported 2 · recomputed 2.833333
Rated minor: it would not touch a result — a value no result rests on, a p-value that stays on the same side of the significance level, or a conflict that is clerical, resolved elsewhere in the paper, or outside its own findings.
In the paper
“Ramalho et al. [34] investigated the indoor CO 2 concentration in 489 mechanically ventilated classrooms in France, and the results indicated that 33% of the samples had a CO 2 concentration above 1700 ppm, which is two times greater than the CIBSE value.”
§ Investigation of Indoor Air Quality and the Identification of Influential Factors at Primary Schools in the North of China > 1. Introduction
Reported 2 · recomputed 2.833333
Citations
Cites
Daisey, J. M., Angell, W. J., & Apte, M. G. (2003) · Indoor Air · doi:10.1034/j.1600-0668.2003.00153.x · Cited by 977
Seppanen, O. A., Fisk, W. J., & Mendell, M. J. (1999) · Indoor Air · doi:10.1111/j.1600-0668.1999.00003.x · Cited by 876 · cited 1×
“[14] found that the risk of air-related health problems can be decreased when CO2 concentrations fall below 800 ppm.”
BackgroundVentilation rates and health: Multidisciplinary review of the scientific literature
Sundell, J., Levin, H., Nazaroff, W. W., Cain, W. S., Fisk, W. J., Grimsrud, D. T., Gyntelberg, F., Li, Y., Persily, A. K., Pickering, A. C., et al. (2011) · Indoor Air · doi:10.1111/j.1600-0668.2010.00703.x · Cited by 740 · cited 1×
“[8] concluded that the incidence of inflammation, respiratory infections, asthma symptoms, and short-term sickness is enhanced as a result of high exposure to air pollutants.”
BackgroundJanssen, N. A. H., Brunekreef, B., van Vliet, P., Aarts, F., Meliefste, K., Harssema, H., & Fischer, P. (2003) · Environmental Health Perspectives · doi:10.1289/ehp.6243 · Cited by 422 · cited 1×
“[27] pointed out that schools close to roadways with heavy traffic usually have higher numbers of children suffering from bronchial hyper responsiveness, positive allergic sensitization, or both, compared with schools located far away from the traffic or industrial areas.”
BackgroundIndoor particulate matter of outdoor origin: Importance of size-dependent removal mechanisms
Riley, W. J., McKone, T. E., Lai, A. C. K., & Nazaroff, W. W. (2002) · Environmental Science & Technology · doi:10.1021/es010723y · Cited by 417 · cited 1×
“[10] suggested that the penetration of particles through building cracks would significantly affect indoor air quality, especially for buildings where air exchange through openings or cracks is dominated by pressure differences arising from natural forces.”
BackgroundRelative contribution of outdoor and indoor particle sources to indoor concentrations
Abt, E., Suh, H. H., Catalano, P., & Koutrakis, P. (2000) · Environmental Science & Technology · doi:10.1021/es990348y · Cited by 411 · cited 1×
“[12] found that cleaning activities and the movement of people significantly increased PM(0.”
BackgroundFang, L., Wyon, D. P., Clausen, G., & Fanger, P. O. (2004) · Indoor Air · doi:10.1111/j.1600-0668.2004.00276.x · Cited by 380 · cited 1×
“[15] indicated that indoor air temperature has great impact on perceived air quality in office buildings, and high air temperatures can promote the generation of other pollutants, such as volatile organic compounds (VOCs) and formaldehyde.”
BackgroundCharacterization of Indoor Particle Sources Using Continuous Mass and Size Monitors
Long, C. M., Suh, H. H., & Koutrakis, P. (2000) · Journal of the Air & Waste Management Association · doi:10.1080/10473289.2000.10464154 · Cited by 364 · cited 1×
“[13] investigated nine homes in Boston and figured out that dusting, vigorous walking, and sautéing were the key factors affecting indoor air quality.”
BackgroundMechanisms underlying Children's susceptibility to environmental toxicants.
Faustman, E. M., Silbernagel, S. M., Fenske, R. A., Burbacher, T. M., & Ponce, R. A. (2000) · Environmental Health Perspectives · doi:10.1289/ehp.00108s113 · Cited by 344 · cited 1×
“Children are more sensitive when they are exposed to unhealthy air, because they generally breathe a higher volume of air relative to body weight at a faster rate [16,17].”
BackgroundAssociation between substandard classroom ventilation rates and students’ academic achievement
Haverinen-Shaughnessy, U., Moschandreas, D. J., & Shaughnessy, R. J. (2011) · Indoor Air · doi:10.1111/j.1600-0668.2010.00686.x · Cited by 311 · cited 1×
“[20] investigated one hundred elementary schools in the southwest of the U.”
Background
Research works printed but not linked: 1
- Lin, B. (2012). China Energy Development Report 2012, Press of Peking University.
Cited by
Tran, V. V., Park, D., & Lee, Y.-C. (2020) · International Journal of Environmental Research and Public Health · doi:10.3390/ijerph17082927 · Cited by 822
“It has been indicated that IAQ in residential areas or buildings is significantly affected by three primary factors [12,13]: (i) Outdoor air quality, (ii) human activity in buildings, and (iii) building and construction materials, equipment, and furniture.”
BackgroundAzuma, K., Kagi, N., Yanagi, U., & Osawa, H. (2018) · Environment International · doi:10.1016/j.envint.2018.08.059 · Cited by 403
Pettit, T. J., Irga, P. J., & Torpy, F. R. (2018) · Air Quality Atmosphere & Health · doi:10.1007/s11869-018-0628-7 · Cited by 106
“…poor air quality (Gulia et al. 2015; Han et al. 2014), as the activities in these areas promote the generation of airborne pollutants, primarily particulate matter (PM) (Guo et al. 2010; Morawska and Clark 2000), which can penetrate and contaminate the urban indoor environment (Perez et al. 2016).”
BackgroundOthman, M., Latif, M. T., & Matsumi, Y. (2018) · Ecotoxicology and Environmental Safety · doi:10.1016/j.ecoenv.2018.12.042 · Cited by 82
Indoor Air Pollution and Health: Bridging Perspectives from Developing and Developed Countries
Pillarisetti, A., Ye, W., & Chowdhury, S. (2022) · Annual Review of Environment and Resources · doi:10.1146/annurev-environ-012220-010602 · Cited by 93
Choe, Y., Shin, J.-S., Park, J., Kim, E., Oh, N., Min, K., Kim, D., Sung, K., Cho, M., & Yang, W. (2021) · Building and Environment · doi:10.1016/j.buildenv.2021.108450 · Cited by 65
Indoor air quality in schools in Beijing: Field tests, problems and recommendations
Cai, C., Sun, Z., Weschler, L. B., Li, T., Xu, W., & Zhang, Y. (2021) · Building and Environment · doi:10.1016/j.buildenv.2021.108179 · Cited by 66
A Review of Field Measurement Studies on Thermal Comfort, Indoor Air Quality and Virus Risk
Kakoulli, C., Kyriacou, A., & Michaelides, M. P. (2022) · Atmosphere · doi:10.3390/atmos13020191 · Cited by 66
“[85] X X X OTS N/A [86] X X X X X X X OTS N/A X”
BackgroundScoping review of indoor air quality indexes: Characterization and applications
Pourkiaei, M., & Romain, A.-C. (2023) · Journal of Building Engineering · doi:10.1016/j.jobe.2023.106703 · Cited by 58
Tashakor, M., Behrooz, R. D., Asvad, S. R., & Kaskaoutis, D. G. (2022) · International Journal of Environmental Research and Public Health · doi:10.3390/ijerph19137905 · Cited by 51
“Therefore, improving air tightness of a building is an important pathway to limit the incoming of outdoor air pollutants, while mechanical ventilation with efficient air purification systems, such as HEPA, should be followed for highly polluted conditions [14,15,111].”
BackgroundEffect of the passive natural ventilation on the bioaerosol in a small room
Núñez, A., & García, A. M. (2021) · Building and Environment · doi:10.1016/j.buildenv.2021.108438 · Cited by 46
Sun, C., Zhang, J., Guo, Y., Fu, Q., Liu, W., Pan, J., Huang, Y., Zou, Z., & Huang, C. (2018) · Energy and Buildings · doi:10.1016/j.enbuild.2018.06.005 · Cited by 49
Kim, M. K., & Choi, J.-H. (2019) · Atmospheric Environment · doi:10.1016/j.atmosenv.2019.04.015 · Cited by 44
Balocco, C., & Colaianni, A. (2018) · Sustainability · doi:10.3390/su10062054 · Cited by 41
Balocco, C., & Leoncini, L. (2020) · Sustainability · doi:10.3390/su12208737 · Cited by 36
Indoor Air Quality Levels in Schools: Role of Student Activities and No Activities
Settimo, G., Indinnimeo, L., Inglessis, M., et al. (2020) · International Journal of Environmental Research and Public Health · doi:10.3390/ijerph17186695 · Cited by 34
Zhang, A., Liu, Y., Zhao, B., Zhang, Y., Kan, H., Zhao, Z., Deng, F., Huang, C., Zeng, X., Sun, Y., et al. (2021) · Building and Environment · doi:10.1016/j.buildenv.2021.107898 · Cited by 35
“3 μg/m3) as a result of heavy air pollution [95].”
BackgroundLevels of PM 10 and PM 2.5 and Respiratory Health Impacts on School-Going Children in Kenya
Were, F. H., Wafula, G. A., Lukorito, C., & Kamanu, T. (2020) · Journal of Health and Pollution · doi:10.5696/2156-9614-10.27.200912 · Cited by 37
A review of research on the impact of the classroom physical environment on schoolchildren's health
Fang, Y., Luo, X., & Lu, J. (2022) · Journal of Building Engineering · doi:10.1016/j.jobe.2022.105430 · Cited by 46
Integrated Evaluation of Indoor Particulate Exposure: The VIEPI Project
Pelliccioni, A., Monti, P., Cattani, G., et al. (2020) · Sustainability · doi:10.3390/su12229758 · Cited by 32
The impacts of cooking and indoor air quality assessment in the southwestern region of Bangladesh
Akteruzzaman, M., Rahman, M. A., Rabbi, F. M., et al. (2023) · Heliyon · doi:10.1016/j.heliyon.2023.e12852 · Cited by 31
“Moreover, fine and ultra-fine particulate matter have a negative impact on the cardiovascular system and have been reported by epidemiological researchers [17-20].”
BackgroundChe, W., Li, A. T. Y., Frey, H. C., Tang, K. T. J., Sun, L., Wei, P., Hossain, M. S., Hohenberger, T. L., Leung, K. W., & Lau, A. K. H. (2020) · Indoor Air · doi:10.1111/ina.12725 · Cited by 32
Chen, C., Liu, S., Dong, W., Song, Y., Chu, M., Xu, J., Guo, X., Zhao, B., & Deng, F. (2020) · The Science of The Total Environment · doi:10.1016/j.scitotenv.2020.141726 · Cited by 29
Tran, T. D., Phuong, N. M., Nghiem, T.-D., Lê, T. H., Tu, M. B., Alleman, L., Viet, N. M., Pham, D. T., Ha, N. M., Dang, M. N., et al. (2020) · Atmosphere · doi:10.3390/atmos11050519 · Cited by 32
“8 [38] Preschools Urban, China 32−274 33−267 [34] Preschool and elementary Rural, Portugal 73.”
ResultLiu, X., Liu, X., Liu, X., et al. (2020) · Building and Environment · doi:10.1016/j.buildenv.2020.106735 · Cited by 28
A study on variation laws of infiltration rate with mechanical ventilation rate in a room
Shi, Y., & Li, X. (2018) · Building and Environment · doi:10.1016/j.buildenv.2018.07.021 · Cited by 27
Peng, Z., Deng, W., & Tenório, R. (2020) · Building and Environment · doi:10.1016/j.buildenv.2020.107153 · Cited by 27
Self-citationTariq, S., Loy-Benitez, J., Nam, K., Kim, S., Kim, M., & Yoo, C. (2022) · Tunnelling and Underground Space Technology · doi:10.1016/j.tust.2022.104843 · Cited by 27
Shi, Y., & Li, X. (2018) · Building and Environment · doi:10.1016/j.buildenv.2017.12.033 · Cited by 25
In-vehicle carbon dioxide and adverse effects: An air filtration-based intervention study
Chen, R.-Y., Ho, K., Chang, T.-Y., et al. (2020) · The Science of The Total Environment · doi:10.1016/j.scitotenv.2020.138047 · Cited by 24
Kureshi, R. R., Thakker, D., Mishra, B. K., & Barnes, J. (2023) · Sensors · doi:10.3390/s23073613 · Cited by 28
Li, Z., Di, Z., Chang, M., Ji, Z., Tanaka, T., & Kuroi, K. (2022) · Journal of Building Engineering · doi:10.1016/j.jobe.2022.105240 · Cited by 23
Kausar, A., Ahmad, I., Zhu, T., Shahzad, H., & Eisa, M. H. (2023) · Pollutants · doi:10.3390/pollutants3010011 · Cited by 24
“Outdoor air pollutants directly influence IAQ due to the possible transfer of toxins from the outdoors to indoor atmosphere [10].”
BackgroundIndoor Air Quality Monitoring Using Infrastructure-Based Motion Detectors
Motlagh, N. H., Zaidan, M. A., Lagerspetz, E., Varjonen, S., Toivonen, J., Mineraud, J., Rebeiro‐Hargrave, A., Siekkinen, M., Hussein, T., Nurmi, P., et al. (2019) · IEEE International Conference on Industrial Informatics (INDIN) · doi:10.1109/indin41052.2019.8972332 · Cited by 22
“5 and CO2 emissions are linked with health concerns [3], [4].”
BackgroundAssessment of Daily Personal PM2.5 Exposure Level According to Four Major Activities among Children
Woo, J., Rudasingwa, G., & Kim, S. (2019) · Applied Sciences · doi:10.3390/app10010159 · Cited by 20
“5 from outside to inside should be further investigated [22].”
BackgroundQassimi, N. A., & Jung, C. (2022) · Frontiers in Built Environment · doi:10.3389/fbuil.2021.803516 · Cited by 20
Ma, F., Zhan, C., & Xu, X. (2019) · Energies · doi:10.3390/en12091602 · Cited by 22
Peng, Z., Deng, W., Hong, Y., et al. (2020) · Air Quality Atmosphere & Health · doi:10.1007/s11869-020-00806-w · Cited by 19
Self-citationPalmisani, J., Gilio, A. D., Cisternino, E., et al. (2020) · Sustainability · doi:10.3390/su12072577 · Cited by 18
Bi, D., Qiu, Y., Cheng, H., et al. (2018) · Building and Environment · doi:10.1016/j.buildenv.2018.04.008 · Cited by 17
Amouei, A., Aghalari, Z., Zarei, A., Afsharnia, M., Geraili, Z., & Qasemi, M. (2019) · Indoor and Built Environment · doi:10.1177/1420326x19842302 · Cited by 17
“In addition in China, the outdoor air pollution is very poor in Winter, but doors and windows are often closed to keep the classroom warm, resulting in poor air supply and increased indoor air pollution.(26) Ventilation is an important factor in the indoor environment, especially in schools.”
InfluentialVentilation Strategies for Highly Occupied Public Environments: A Review
Zhang, Y., Guo, Z., Zhuo, L., An, N., & Han, Y. (2023) · Buildings · doi:10.3390/buildings13071642 · Cited by 15
Extracting the Critical Points of Formaldehyde (HCHO) Emission Model in Hot Desert Climate
Jung, C., & Mahmoud, N. S. A. (2022) · Air Soil and Water Research · doi:10.1177/11786221221105082 · Cited by 14
Samangsri, S., Areerob, T., & Chiarakorn, S. (2023) · Catalysts · doi:10.3390/catal13020351 · Cited by 14
“The significant parameters that affect IAQ include the construction materials and furniture in households, as well as the human activities in buildings [5,6].”
BackgroundMandal, D. K., Bose, S., Biswas, N., Manna, N. K., Santra, S., Cüce, E., & Alshahrani, S. (2025) · Solar Energy · doi:10.1016/j.solener.2025.113442 · Cited by 15
Nimra, A., Ali, Z., Nasir, Z. A., Tyrrel, S., & Sidra, S. (2021) · Sains Malaysiana · doi:10.17576/jsm-2021-5006-09 · Cited by 13
Han, S., Kang, J., Park, Y., Kim, J., Son, Y., Kim, J., & Choi, W. (2025) · Building and Environment · doi:10.1016/j.buildenv.2025.112674 · Cited by 12
Impact of Indoor Air Pollution in Pakistan—Causes and Management
Kausar, A., Ahmad, I., Zhu, T., & Shahzad, H. (2023) · Pollutants · doi:10.3390/pollutants3020021 · Cited by 20
Insights on Air Pollution During COVID-19: A Review
Kumar, S. (2023) · Aerosol Science and Engineering · doi:10.1007/s41810-023-00173-w · Cited by 11
Peng, Z., Cheng, Y., Jiang, M., Shu, S., & Geng, X. (2023) · Journal of Building Engineering · doi:10.1016/j.jobe.2023.107065 · Cited by 11
Self-citationFu, N., Kim, M. K., Chen, B., & Sharples, S. (2021) · Sustainability · doi:10.3390/su13158453 · Cited by 10
Balocco, C., & Colaianni, A. (2018) · Sustainability · doi:10.3390/su10103776 · Cited by 10
Assessment of PM2.5 penetration based on airflow paths in Korean classrooms
Kim, S., Kang, K., Park, D., & Kim, T. (2023) · Building and Environment · doi:10.1016/j.buildenv.2023.111103 · Cited by 10
Sallan, S., Kwong, Q. J., Ling, O. H. L., et al. (2025) · Facilities · doi:10.1108/f-09-2024-0137 · Cited by 7
Indoor Air Quality and Smoking Control in Healthcare Environments in Northern China
Zhang, S., Song, K., Ban, Q., Gong, P., Li, R., & Peng, Z. (2023) · Sustainability · doi:10.3390/su15054041 · Cited by 7
Self-citationKhazaei, A., Ghafari, F., Pang, Z., et al. (2025) · Journal of Building Engineering · doi:10.1016/j.jobe.2025.112937 · Cited by 6
Choudhury, A. R., Singh, N. C., Chinthala, S., et al. (2025) · Environmental Science Atmospheres · doi:10.1039/d5ea00027k · Cited by 6
Control of Different Parameters for Indoor Air Quality Management Through Natural Ventilation
Pepe, C., Farooq, A. M., & Zanoli, S. M. (2024) · International Carpathian Control Conference · doi:10.1109/iccc62069.2024.10569334 · Cited by 5
“Generally, the main components that have been found to have a substantial impact on IAQ in residential areas and structures are: (i) outdoor air quality; (ii) human activities within buildings; (iii) building and construction materials, equipment, and furnishings [3], [4], [5].”
BackgroundIsa, F. M., Mustapha, A. A., Adnan, H., Ahmad, C. B., & Mutiara, M. W. (2022) · IOP Conference Series Earth and Environmental Science · doi:10.1088/1755-1315/1067/1/012028 · Cited by 5
Assessing the seasonality of occupancy number-associated CO2 level in a Taiwan hospital
Li, Y., Tseng, W.-C., Hsieh, N., & Chen, S. (2019) · Environmental Science and Pollution Research · doi:10.1007/s11356-019-05084-3 · Cited by 5
From Green to Healthy Buildings: A Comparative Study of the USA and China
Xie, X., & Gou, Z. (2019) · Green energy and technology · doi:10.1007/978-3-030-24650-1_5 · Cited by 5
Jung, C., & Mahmoud, N. S. A. (2023) · Frontiers in Built Environment · doi:10.3389/fbuil.2023.1297520 · Cited by 5
Narayanan, V., Shaikh, R., Hashemi, A., et al. (2024) · Environmental Science & Sustainable Development · doi:10.21625/essd.v9i3.1072 · Cited by 4
Peng, Z., Deng, W., & Hong, Y. (2019) · IOP Conference Series Earth and Environmental Science · doi:10.1088/1755-1315/281/1/012018 · Cited by 4
Self-citationKanjanasiranont, N., Prueksasit, T., & Sahanavin, N. (2021) · Applied Environmental Research · doi:10.35762/aer.2021.43.2.2 · Cited by 4
Lucas, R. E. C., da Silva, L. B., de Souza, E. L., et al. (2024) · Work · doi:10.3233/wor-220055 · Cited by 4
Ventilação natural e qualidade do ar em salas de aula: revisão sistemática da literatura
Silva, S. V. D. O., Pagel, É. C., Bastos, L. E. G., & Santos, C. M. L. (2022) · PARC Pesquisa em Arquitetura e Construção · doi:10.20396/parc.v13i00.8666284 · Cited by 11
A COMPREHENSIVE REVIEW OF INDOOR AIR POLLUTANTS: SOURCES, EFFECTS, AND MITIGATION STRATEGIES
Yadav, S., Kumar, N., Kumar, V., Jha, V., & Chhikara, S. K. (2023) · PLANT ARCHIVES · doi:10.51470/plantarchives.2023.v23.no2.045 · Cited by 3
Tekin, Ö. F., & Arıkan, İ. (2023) · Eskişehir Türk Dünyası Uygulama ve Araştırma Merkezi Halk Sağlığı Dergisi · doi:10.35232/estudamhsd.1222791 · Cited by 3
“In most studies where PM 2.5 and PM 10 measurements were performed in the school environment, measurement results were found to be higher than the WHO criteria (24, 25).”
MethodInfluentialArıkan, İ., & Tekin, Ö. F. (2023) · Cyprus Journal of Medical Sciences · doi:10.4274/cjms.2021.2021-91 · Cited by 3
Wang, L., Gao, K., Li, W., et al. (2024) · Environmental Science and Pollution Research · doi:10.1007/s11356-023-31723-x · Cited by 3
“Generally, indoor pollution sources can be divided into three types, indoor human activities, the release of indoor building materials and consumer products, and infiltration of outdoor pollutants (Pekey et al. 2010; Kulshrestha et al. 2014; Peng et al. 2017; Ielpo et al. 2021).”
Ventilation and indoor air quality
Suman, S., Thera, E. D., & Kumar, N. (2024) · Elsevier eBooks · doi:10.1016/b978-0-443-16090-5.00007-6 · Cited by 3
Duan, X., Shen, C., Chen, G., et al. (2024) · Indoor Air · doi:10.1155/2024/8813703 · Cited by 3
Determining ventilation strategies to relieve health symptoms among school occupants
Uotila, U., & Saari, A. (2023) · Facilities · doi:10.1108/f-10-2021-0101 · Cited by 3
Baharfar, Y., Mohammadyan, M., Moattar, F., et al. (2021) · Smart and Sustainable Built Environment · doi:10.1108/sasbe-12-2020-0183 · Cited by 3
Innovative Antifungal Photocatalytic Paint for Improving Indoor Environment
Ojo, S., Tsai, Y. H., Samia, A. C. S., et al. (2024) · Catalysts · doi:10.3390/catal14110783 · Cited by 2
Ma, X., Li, Y., Liao, X., et al. (2025) · Ecotoxicology and Environmental Safety · doi:10.1016/j.ecoenv.2025.119434 · Cited by 2
Defining a protocol for evaluation of indoor air quality in school buildings
Lukić, N. S., & Radivojević, A. (2023) · Facta universitatis - series Architecture and Civil Engineering · doi:10.2298/fuace230531015l · Cited by 2
Oluchi, O. C., Jalaludin, J., Isa, K. N. M., Nordin, S. B. A., Abubakar, S., & Choo, V. C. P. (2024) · Air Quality Atmosphere & Health · doi:10.1007/s11869-024-01545-y · Cited by 5
“…settings have also reported that prolonged exposure to air pollutants can lead to more serious health issues such as mucous membrane irritations, neurotoxic effects, lung inflammation and cancer (Deng et al. 2023; Lei et al. 2024; Baccouche and Sevostianov 2020; Zeng et al. 2016; Peng et al. 2017).”
Balance point concentration: An indicator for classroom performance against outdoor PM2.5
Kim, S., Kang, K., Park, D., et al. (2024) · Building and Environment · doi:10.1016/j.buildenv.2024.112021 · Cited by 2
Park, D., Han, S. H., Park, D. J., et al. (2024) · Heliyon · doi:10.1016/j.heliyon.2024.e26284 · Cited by 1
“5 [8].”
Abdullah, F., Jaafar, M. H., Ahmad, M. I., & Samsudin, M. S. (2025) · ACS Chemical Health & Safety · doi:10.1021/acs.chas.5c00094 · Cited by 1
Biswas, S., Elma, S. I., & Kabir, A. (2025) · Water Air & Soil Pollution · doi:10.1007/s11270-025-08511-z · Cited by 1
“The responsible factors for high concentration of IAQ parameters were reported as poor ventilation systems, high occupation, and building defects (Branco et al., 2015; Peng et al., 2017).”
Indoor air quality assessment using low-cost sensors, and impact of outdoors
Dahima, Y., & Vaishya, A. (2025) · Air Quality Atmosphere & Health · doi:10.1007/s11869-025-01843-z · Cited by 1
“…to academic campuses, and neglects simultaneous multi-microenvironment assessments and rigorous evaluation of LCS against FEM reference instruments before deployment and analysis (Dorizas et al. 2015; Habil et al. 2013; Peng et al. 2017; Pritwani and Devasenapathy 2024; Sahu and Gurjar 2020).”
Health Impact of Indoor Air Quality: Biological, Physical and Economic Considerations
Ukpene, A. O., Molua, O. C., Ukpene, C. P., Emagbetere, J. U., & Igbogbor, J. C. (2023) · Journal Healthcare Treatment Development · doi:10.55529/jhtd.41.27.38 · Cited by 2
Investigation of Indoor Air Quality in Several Offices in Baghdad – Case Study
Rikabi, I. J. A., Abuelnour, M. A., Abed, T. K., Al-Obaidy, A. H., & Omara, A. A. M. (2022) · International Engineering Conference on Sustainable Technology and Development (IEC) · doi:10.1109/iec54822.2022.9807508 · Cited by 2
Mundackal, A. J. (2020) · Unisa Institutional Repository (University of South Africa) · Cited by 1
The Impacts of Cooking and Indoor Air Quality Assessment in the Southwestern Region of BangladeshPreprint
Akteruzzaman, M., Rahman, M. A., Yasmeen, S., et al. (2022) · SSRN Electronic Journal · doi:10.2139/ssrn.4185411 · Cited by 1
Electrospun fibres for supply air filtration in residential buildings: an experimental study
Orlando, R. (2021) · VBN Forskningsportal (Aalborg Universitet) · doi:10.54337/aau468596978 · Cited by 1
TRAN, D.-T., NGUYEN, M.-P., DANG, N.-M., & PHAM, T.-T. (2022) · Pollution Research · doi:10.53550/pr.2022.v41i03.012
QUALIDADE DO AR INTERIOR E CONTRIBUIÇÃO NO COMBATE À PANDEMIA DO COVID-19
Lopes, D. L., & Almeida, A. G. S. (2023) · DESAFIOS Revista Interdisciplinar da Universidade Federal do Tocantins · doi:10.20873/uftv1n123-13921 · Cited by 3
Determination of Heavy Metal Concentrations in Household Dusts in Irbid and Mafraq Cities, Jordan
Al-Serhan, A. A., Al‐Massaedh, “. A., & Al-Momani, I. F. (2023) · Indonesian Journal of Chemistry · doi:10.22146/ijc.85062
“Moreover, several environmental studies have reported the impact of indoor pollutants on the academic achievement and mental stability of children [3,4,22].”
Backgroundimpacto da renovação do ar na qualidade interna do ar e no condicionamento térmico de salas de aula
Pereira, T. V., Scalco, V. A., & Silva, C. F. E. (2023) · Encontro Nacional de Conforto no Ambiente Construído e Encontro Latino-Americano de Conforto no Ambiente Construído · doi:10.46421/encac.v17i1.4629
Assessment of Comprehensive Performance of Pm2.5 in ClassroomPreprint
Kim, T., Kim, S., & Kang, K. (2024) · SSRN Electronic Journal · doi:10.2139/ssrn.4857535
Natural and Mechanical Ventilation Management for Indoor Air Quality MPC
Pepe, C., & Zanoli, S. M. (2025) · IFAC-PapersOnLine · doi:10.1016/j.ifacol.2025.08.138
Comparison of Rule-Based, PID and MPC Strategies for Flexible IAQ Control
Pepe, C., & Zanoli, S. M. (2025) · IEEE International Conference on Industry Applications · doi:10.1109/induscon66435.2025.11241658
“Building and construction materials, human activities within buildings, equipment and furnishings, represent significant factors in this field [5].”
Ahmed, S., Hossain, R., Moniruzzaman, M., Parvin, A., Haider, M., & Hossain, M. S. (2026) · Air Quality Atmosphere & Health · doi:10.1007/s11869-026-01940-7 · Cited by 1
Air purification and indoor air quality of green microbial nanotechnology for pollution control
Azid, A., Hassan, A., Samsudin, M. S., Rani, N. L. A., & Ali, N. I. M. (2026) · Elsevier eBooks · doi:10.1016/b978-0-443-43958-2.00024-8 · Cited by 1
Crespino, E., Campagna, L. M., & Carlucci, F. (2026) · UNIPA Springer series · doi:10.1007/978-3-032-16019-5_2
Zhang, F., Shi, L., Zhang, Y., Liu, S., & Long, M. (2026) · Buildings · doi:10.3390/buildings16112220
Metadata
- Authors
- Peng, Z., Deng, W., & Tenorio, R.
- Affiliations
- University of Nottingham Ningbo China (CN)
- Department of Architecture and Built Environment, the University of Nottingham Ningbo China, 199 Taikang East Road, Ningbo 315100, China
- Corresponding author
- Deng, Wu
- ORCID
- Venue
- Sustainability
- Publisher
- MDPI AG
- Published
- 2017-07-05
- Volume
- 9
- Issue
- 7
- Pages
- 1180
- ISSN
- 2071-1050 (ISSN-L)
- OpenAlex
- W2729710293
- Cited by
- 109
- References
- 32
- Citations by year
- 2026: 8 · 2025: 14 · 2024: 13 · 2023: 21 · 2022: 13 · 2021: 9 · 2020: 14 · 2019: 8 · 2018: 9
- FWCI
- 4.31
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Licence
- Locations
- Sustainability (publishedVersion, cc-by)
- Nottingham ePrints (University of Nottingham) (submittedVersion, cc-by)
- Repository@Nottingham (University of Nottingham) (submittedVersion, cc-by)
- RePEc: Research Papers in Economics (submittedVersion)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
- Topics
- Physical Sciences › Environmental Science › Health, Toxicology and Mutagenesis › Indoor Air Quality and Microbial Exposure
- Physical Sciences › Engineering › Building and Construction › Building Energy and Comfort Optimization
- Health Sciences › Medicine › Pulmonary and Respiratory Medicine › Infection Control and Ventilation
- Keywords
- indoor air quality, elementary school, naturally ventilated buildings, particulate matter, PM2.5, PM10, carbon dioxide, indoor-outdoor concentration ratio, construction defects, occupant activities, indoor temperature, ambient air pollution, mechanical ventilation, air purification, North China
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
The claim verdicts this report counts are experimental: their accuracy is not yet measured.
A language model drew the claims from the paper on 2026-09-28, under version 3 of the claim definition (prompt extract-v3).
A second model labelled each claim on 2026-09-28 (model jev-1.13-20260917, definition revision gold-guideline-v0.2).
Cited sources are checked with a language model’s help (gpt-6-sol).
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.