A standardized validity assessment protocol for physiological signals from wearable technology: Methodological underpinnings and an application to the E4 biosensor
Open accessThe DOI matches its Crossref record; 19 of the 19 references it cites were found in a registry or an index.
Abstract
Wearable physiological measurement devices for ambulatory research with novel sensing technology are introduced with ever increasing frequency, requiring fast, standardized, and rigorous validation of the physiological signals measured by these devices and their derived parameters. At present, there is a lack of consensus on a standardized protocol or framework with which to test the validity of this new technology, leading to the use of various (often unfit) methods. This study introduces a comprehensive validity assessment protocol for physiological signals (electrodermal activity and cardiovascular activity) and investigates the validity of the E4 wearable (an example of such a new device) on the three levels proposed by the protocol: (1) the signal level, with a cross-correlation; (2) the parameter level, with Bland-Altman plots; and (3) the event level, with the detection of physiological changes due to external stressor levels via event difference plots. The results of the protocol show that the E4 wearable is valid for heart rate, RMSSD, and SD at the parameter and event levels, and for the total amplitude of skin conductance responses at the event level when studying strong sustained stressors. These findings are in line with the prior literature and demonstrate the applicability of the protocol. The validity assessment protocol proposed in this study provides a comprehensive, standardized, and feasible method for assessment of the quality of physiological data coming from new wearable (sensor) technology aimed at ambulatory research.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
Statistical power analyses using G∗Power 3.1: tests for correlation and regression analyses
Faul, F., Erdfelder, E., Buchner, A., & Lang, A.-G. (2009) · Behavior Research Methods · doi:10.3758/brm.41.4.1149 · Cited by 37,615
A Real-Time QRS Detection Algorithm
Pan, J., & Tompkins, W. J. (1985) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1985.325532 · Cited by 7,855 · cited 1×
“Analyze the filtered data The raw ECG and PPG recorded was filtered with a combination of low-pass and high-pass filters between 5 and 15 Hz (Pan & Tompkins, 1985).”
MethodForming inferences about some intraclass correlation coefficients.
McGraw, K. O., & Wong, S. P. (1996) · Psychological Methods · doi:10.1037/1082-989x.1.1.30 · Cited by 6,903
Kirschbaum, C., Pirke, K.-M., & Hellhammer, D. H. (2008) · Neuropsychobiology · doi:10.1159/000119004 · Cited by 6,093
Understanding bland altman analysis
Giavarina, D. (2015) · Biochemia Medica · doi:10.11613/bm.2015.015 · Cited by 4,706
(2001) · doi:10.1017/cbo9780511546396 · Cited by 4,482
Boucsein, W. (2012) · doi:10.1007/978-1-4614-1126-0 · Cited by 2,526
A Survey on Wearable Sensor-Based Systems for Health Monitoring and Prognosis
Pantelopoulos, A., & Bourbakis, N. G. (2010) · IEEE Transactions on Systems Man and Cybernetics Part C (Applications and Reviews) · doi:10.1109/tsmcc.2009.2032660 · Cited by 2,296 · cited 1×
“However, for measuring EDA, only a small number of wireless devices are currently available (Majumder, Mondal, & Deen, 2017), and when needing to collect data from one wearable for both CVA and EDA simultaneously, the number of devices is even lower (Pantelopoulos & Bourbakis, 2010).”
BackgroundWearable Sensors for Remote Health Monitoring
Majumder, S., Mondal, T., & Deen, M. (2017) · Sensors · doi:10.3390/s17010130 · Cited by 1,375
Publication recommendations for electrodermal measurements
Society for Psychophysiological Research Ad Hoc Committee on Electrodermal Measures (2012) · Psychophysiology · doi:10.1111/j.1469-8986.2012.01384.x · Cited by 1,288 · cited 1×
“Some (Boucsein et al., 2012) recommend using the distal phalanges, however comparison within the present study showed no differences between the two phalanges.”
MethodSample size requirements for estimating intraclass correlations with desired precision
Bonett, D. G. (2002) · Statistics in Medicine · doi:10.1002/sim.1108 · Cited by 987 · cited 1×
“Bonett (2002) proposed to investigate the confidence interval (CI) of an ICC instead of comparing it to a constant, leading to a sample size of 55 when the correlation is .8 and the width of the CI is .2.”
BackgroundTrull, T. J., & Ebner-Priemer, U. (2013) · Annual Review of Clinical Psychology · doi:10.1146/annurev-clinpsy-050212-185510 · Cited by 761
A Wearable Sensor for Unobtrusive, Long-Term Assessment of Electrodermal Activity
Poh, M.-Z., Swenson, N. C., & Picard, R. W. (2010) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2009.2038487 · Cited by 693 · cited 4×
“Crosscorrelation is a generalization of Pearson’s correlation (as used by, e.g., Poh et al., 2010, who found a correlation between .93 and .99 for a wearable and RD for EDA) to the displacement in time, through which systematic time delays between the two signals can be detected.”
BackgroundMethodInfluentialOrphanidou, C., Bonnici, T., Charlton, P., Clifton, D., Vallance, D., & Tarassenko, L. (2014) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2014.2338351 · Cited by 368
Cardiovascular Psychophysiology
Berntson, G. G., Quigley, K. S., & Lozano, D. (2009) · Handbook of Psychophysiology · doi:10.1017/cbo9780511546396.008 · Cited by 289
Validation of the Empatica E4 wristband
McCarthy, C., Pradhan, N., Redpath, C., & Adler, A. (2016) · 2016 IEEE EMBS International Student Conference (ISC) · doi:10.1109/embsisc.2016.7508621 · Cited by 235
Reinhardt, T., Schmahl, C., Wüst, S., & Bohus, M. (2012) · Psychiatry Research · doi:10.1016/j.psychres.2011.12.009 · Cited by 189
Photoplethysmogram signal quality estimation using repeated Gaussian filters and cross-correlation
Karlen, W., Kobayashi, K., Ansermino, J. M., & Dumont, G. A. (2012) · Physiological Measurement · doi:10.1088/0967-3334/33/10/1617 · Cited by 123
Cited by
Schuurmans, A. A. T., de Looff, P., Nijhof, K. S., Rosada, C., Scholte, R. H. J., Popma, A., & Otten, R. (2020) · Journal of Medical Systems · doi:10.1007/s10916-020-01648-w · Cited by 210
Vos, G., Trinh, K., Sarnyai, Z., & Rahimi Azghadi, M. (2023) · International Journal of Medical Informatics · doi:10.1016/j.ijmedinf.2023.105026 · Cited by 164
ter Harmsel, J. F., Noordzij, M. L., Goudriaan, A. E., Dekker, J. J. M., Swinkels, L. T. A., van der Pol, T. M., & Popma, A. (2021) · International Journal of Psychophysiology · doi:10.1016/j.ijpsycho.2020.11.009 · Cited by 47
Self-citationDerks, Y. P., Klaassen, R., Westerhof, G. J., Bohlmeijer, E. T., & Noordzij, M. L. (2019) · JMIR mHealth and uHealth · doi:10.2196/13479 · Cited by 45
Self-citation
Metadata
- Authors
- van Lier, H. G., Pieterse, M. E., Garde, A., Postel, M. G., de Haan, H. A., Vollenbroek-Hutten, M. M. R., Schraagen, J. M., & Noordzij, M. L.
- Venue
- Behavior Research Methods
- Published
- 2019-07-09
- Volume
- 52
- Issue
- 2
- Pages
- 607-629
- ISSN
- 1554-351X (ISSN-L)
- 1554-3528
- OpenAlex
- W2961297883
- Cited by
- 133
- References
- 19
- FWCI
- 9.62
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.