The Ascendance of Microphysiological Systems to Solve the Drug Testing Dilemma
Open accessThe DOI matches its Crossref record; 26 of the 26 references it cites were found in a registry or an index.
Abstract
The development of drugs is a process obstructed with manifold security and efficacy concerns. Although animal models are still widely used to meet the diligence required, they are regarded as outdated tools with limited predictability. Novel microphysiological systems intend to create systemic models of human biology. Their ability to host 3D organoid constructs in a controlled microenvironment with mechanical and electrophysiological stimuli enables them to create and maintain homeostasis. These platforms are, thus, envisioned to be superior tools for testing and developing substances such as drugs, cosmetics and chemicals. We will present reasons why microphysiological systems are required for the emerging demands, highlight current technological and regulatory obstacles, and depict possible solutions from state-of-the-art platforms from major contributors.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Reconstituting organ-level lung functions on a chip
Huh, D., Matthews, B. D., Mammoto, A., Montoya-Zavala, M., Hsin, H. Y., & Ingber, D. E. (2010) · Science · doi:10.1126/science.1188302 · Cited by 4,250
How to improve R&D productivity: the pharmaceutical industry's grand challenge
Paul, S. M., Mytelka, D. S., Dunwiddie, C. T., Persinger, C. C., Munos, B. H., Lindborg, S. R., & Schacht, A. L. (2010) · Nature Reviews Drug Discovery · doi:10.1038/nrd3078 · Cited by 3,566
Innovation in the pharmaceutical industry: New estimates of R&D costs
DiMasi, J. A., Grabowski, H. G., & Hansen, R. W. (2016) · Journal of Health Economics · doi:10.1016/j.jhealeco.2016.01.012 · Cited by 3,359
Genomic responses in mouse models poorly mimic human inflammatory diseases
Seok, J., Warren, H. S., Cuenca, A. G., Mindrinos, M. N., Baker, H. V., Xu, W., Richards, D. R., McDonald-Smith, G. P., Gao, H., Hennessy, L., et al. (2013) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1222878110 · Cited by 3,005
Clinical development success rates for investigational drugs
Hay, M., Thomas, D. W., Craighead, J. L., Economides, C., & Rosenthal, J. (2014) · Nature Biotechnology · doi:10.1038/nbt.2786 · Cited by 2,536
Kim, H. J., Huh, D., Hamilton, G., & Ingber, D. E. (2012) · Lab on a Chip · doi:10.1039/c2lc40074j · Cited by 1,734
An analysis of the attrition of drug candidates from four major pharmaceutical companies
Waring, M. J., Arrowsmith, J., Leach, A. R., Leeson, P. D., Mandrell, S., Owen, R. M., Pairaudeau, G., Pennie, W. D., Pickett, S. D., Wang, J., et al. (2015) · Nature Reviews Drug Discovery · doi:10.1038/nrd4609 · Cited by 1,450
Can Animal Models of Disease Reliably Inform Human Studies?
van der Worp, H. B., Howells, D. W., Sena, E. S., Porritt, M. J., Rewell, S., O'Collins, V., & Macleod, M. R. (2010) · PLoS Medicine · doi:10.1371/journal.pmed.1000245 · Cited by 1,354
Lessons learned from the fate of AstraZeneca's drug pipeline: a five-dimensional framework
Cook, D., Brown, D., Alexander, R., March, R., Morgan, P., Satterthwaite, G., & Pangalos, M. N. (2014) · Nature Reviews Drug Discovery · doi:10.1038/nrd4309 · Cited by 1,344
Maschmeyer, I., Lorenz, A. K., Schimek, K., Hasenberg, T., Ramme, A. P., Hübner, J., Lindner, M., Drewell, C., Bauer, S., Thomas, A., et al. (2015) · Lab on a Chip · doi:10.1039/c5lc00392j · Cited by 861
Self-citationTranslation of Research Evidence From Animals to Humans
Hackam, D. G., & Redelmeier, D. A. (2006) · JAMA · doi:10.1001/jama.296.14.1731 · Cited by 733
Mechanism of the Cardiotoxic Actions of Terfenadine
Woosley, R. L. (1993) · JAMA: The Journal of the American Medical Association · doi:10.1001/jama.1993.03500120070028 · Cited by 646
Screening out irrelevant cell-based models of disease
Horvath, P., Aulner, N., Bickle, M., Davies, A. M., Nery, E. D., Ebner, D., Montoya, M. C., Östling, P., Pietiäinen, V., Price, L. S., et al. (2016) · Nature Reviews Drug Discovery · doi:10.1038/nrd.2016.175 · Cited by 525
Wagner, I., Materne, E.-M., Brincker, S., Süßbier, U., Frädrich, C., Busek, M., Sonntag, F., Sakharov, D. A., Trushkin, E. V., Tonevitsky, A. G., et al. (2013) · Lab on a Chip · doi:10.1039/c3lc50234a · Cited by 476
Self-citationMulti-Organ toxicity demonstration in a functional human in vitro system composed of four organs
Oleaga, C., Bernabini, C., Smith, A. S. T., Srinivasan, B., Jackson, M., McLamb, W., Platt, V., Bridges, R., Cai, Y., Santhanam, N., et al. (2016) · Scientific Reports · doi:10.1038/srep20030 · Cited by 442
The Costs of using Unauthenticated, Over-Passaged Cell Lines: How Much more Data do we Need?
Hughes, P., Marshall, D., Reid, Y., Parkes, H., & Gelber, C. (2007) · BioTechniques · doi:10.2144/000112598 · Cited by 434
Multi-cell type human liver microtissues for hepatotoxicity testing
Messner, S., Agarkova, I., Moritz, W., & Kelm, J. M. (2013) · Archives of Toxicology · doi:10.1007/s00204-012-0968-2 · Cited by 319
Marx, U. (2016) · ALTEX · doi:10.14573/altex.1603161 · Cited by 295
Self-citationScreening Chemicals for Estrogen Receptor Bioactivity Using a Computational Model
Browne, P., Judson, R. S., Casey, W. M., Kleinstreuer, N. C., & Thomas, R. S. (2015) · Environmental Science & Technology · doi:10.1021/acs.est.5b02641 · Cited by 276
Systematic reviews of animal models: methodology versus epistemology
Greek, R., & Menache, A. (2013) · International Journal of Medical Sciences · doi:10.7150/ijms.5529 · Cited by 207
OECD (2005) · OECD Series on Testing and Assessment · doi:10.1787/e1f1244b-en · Cited by 207
Microfluidic titer plate for stratified 3D cell culture
Trietsch, S. J., Israëls, G. D., Joore, J., Hankemeier, T., & Vulto, P. (2013) · Lab on a Chip · doi:10.1039/c3lc50210d · Cited by 189
Good Cell Culture Practice for stem cells and stem-cell-derived models
Pamies, D. (2016) · ALTEX · doi:10.14573/altex.1607121 · Cited by 160
Assessment of whole blood thrombosis in a microfluidic device lined by fixed human endothelium
Jain, A., van der Meer, A. D., Papa, A.-L., Barrile, R., Lai, A., Schlechter, B. L., Otieno, M. A., Louden, C. S., Hamilton, G. A., Michelson, A. D., et al. (2016) · Biomedical Microdevices · doi:10.1007/s10544-016-0095-6 · Cited by 148
3D spherical microtissues and microfluidic technology for multi-tissue experiments and analysis
Kim, J.-Y., Fluri, D. A., Marchan, R., Boonen, K., Mohanty, S., Singh, P., Hammad, S., Landuyt, B., Hengstler, J. G., Kelm, J. M., et al. (2015) · Journal of Biotechnology · doi:10.1016/j.jbiotec.2015.01.003 · Cited by 126
Kleensang, A., Vantangoli, M. M., Odwin-DaCosta, S., Andersen, M. E., Boekelheide, K., Bouhifd, M., Fornace, A. J., Li, H.-H., Livi, C. B., Madnick, S., et al. (2016) · Scientific Reports · doi:10.1038/srep28994 · Cited by 114
Cited by
Advances in organ-on-a-chip engineering
Zhang, B., Korolj, A., Lai, B. F. L., & Radisic, M. (2018) · Nature Reviews Materials · doi:10.1038/s41578-018-0034-7 · Cited by 1,017
Interconnected Microphysiological Systems for Quantitative Biology and Pharmacology Studies
Edington, C. D., Chen, W. L. K., Geishecker, E., Kassis, T., Soenksen, L. R., Bhushan, B. M., Freake, D., Kirschner, J., Maass, C., Tsamandouras, N., et al. (2018) · Scientific Reports · doi:10.1038/s41598-018-22749-0 · Cited by 487
Organ/body-on-a-chip based on microfluidic technology for drug discovery
Kimura, H., Sakai, Y., & Fujii, T. (2018) · Drug Metabolism and Pharmacokinetics · doi:10.1016/j.dmpk.2017.11.003 · Cited by 435
Bauer, S., Wennberg Huldt, C., Kanebratt, K. P., Durieux, I., Gunne, D., Andersson, S., Ewart, L., Haynes, W. G., Maschmeyer, I., Winter, A., et al. (2017) · Scientific Reports · doi:10.1038/s41598-017-14815-w · Cited by 272
Self-citationRecent Advances in Body-on-a-Chip Systems
Sung, J. H., Wang, Y. I., Narasimhan Sriram, N., Jackson, M., Long, C., Hickman, J. J., & Shuler, M. L. (2019) · Analytical Chemistry · doi:10.1021/acs.analchem.8b05293 · Cited by 268
Metadata
- Authors
- Dehne, E.-M., Hasenberg, T., & Marx, U.
- Venue
- Future Science OA
- Publisher
- Informa UK Limited
- Published
- 2017-03-31
- Volume
- 3
- Issue
- 2
- Pages
- FSO185-FSO185
- ISSN
- 2056-5623 (ISSN-L)
- OpenAlex
- W2600876560
- Cited by
- 68
- References
- 26
- FWCI
- 5.35
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.