CoChat

An Adaptive-Duration Version of the PVT Accurately Tracks Changes in Psychomotor Vigilance Induced by Sleep Restriction

Open access
Basner, Mathias, Dinges, David F. · 2012 · Sleep
Cited by 78

The DOI matches its Crossref record; 15 of the 15 references it cites were found in a registry or an index.

Abstract

STUDY OBJECTIVES: The Psychomotor Vigilance Test (PVT) is a widely used assay of behavioral alertness sensitive to the effects of sleep loss and circadian misalignment. The standard 10-minute duration of the PVT is often considered impractical for operational or clinical environments. Therefore, we developed and validated an adaptive-duration version of the PVT (PVT-A) that stops sampling once it has gathered enough information to correctly classify PVT performance. DESIGN: Repeated-measures experiments involving 10-minute PVT assessments every 2 hours across both acute total sleep deprivation (TSD) and 5 days of chronic partial sleep deprivation (PSD). SETTING: Controlled laboratory environment. PARTICIPANTS: Seventy-four healthy subjects (34 women), aged 22 to 45 years. INTERVENTIONS: A TSD experiment involving 33 hours awake (n = 31 subjects), and a PSD experiment involving 5 nights of 4 hours time in bed (n = 43 subjects). MEASUREMENTS AND RESULTS: The PVT-A algorithm was trained with 527 TSD test bouts and validated with 880 PSD test bouts. Based on our primary outcome measure "number of lapses (response times ≥ 500 ms) plus false starts (premature responses or response times < 100 ms)," 10-minute PVT performance was classified into high (≤ 5 lapses and false starts), medium (> 5 and ≤ 16 lapses and false starts), or low (> 16 lapses and false starts). The decision threshold for PVT-A termination was set so that at least 95% of training data-set tests were classified correctly and no test was classified incorrectly across 2 performance categories (i.e., high as low or low as high), resulting in an average test duration of 6.0 minutes (SD 2.4 min). In the validation data set, 95.7% of test bouts were correctly classified, and there were no incorrect classifications across 2 categories. Agreement corrected for chance was excellent (κ = 0.92). Across the 3 performance categories, sensitivity averaged 93.7% (range 87.2%-100%), and specificity averaged 96.8% (range 91.6%-99.9%). Test duration averaged 6.4 minutes (SD 1.7 min), with a minimum of 27 seconds. CONCLUSIONS: We developed and validated a highly accurate, sensitive, and specific adaptive-duration version of the 10-minute PVT. Test duration of the adaptive PVT averaged less than 6.5 minutes, with 60 tests (4.3%) terminating after less than 2 minutes, increasing the practicability of the test in operational and clinical settings. The adaptive-duration strategy may be superior to a simple reduction of PVT duration in which the fixed test duration may be too short to identify subjects with moderate impairment (showing deficits only later during the test) but unnecessarily long for those who are either fully alert or severely impaired.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.5665/sleep.1620

Cites

15 of 15 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 15 references

Cited by

Metadata

Authors
Basner, M., & Dinges, D. F.
Venue
Sleep
Published
2012-02
Volume
35
Issue
2
Pages
193-202
ISSN
  • 0161-8105 (ISSN-L)
  • 1550-9109
OpenAlex
W2152354909
Cited by
78
References
15
FWCI
4.96
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.