The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Comparison of a Commercial Accelerometer with Polysomnography and Actigraphy in Children and Adolescents
Open accessAbstract
STUDY OBJECTIVES: To evaluate the reliability and validity of the commercially available Fitbit Ultra (2012) accelerometer compared to polysomnography (PSG) and two different actigraphs in a pediatric sample. DESIGN AND SETTING: All subjects wore the Fitbit Ultra while undergoing overnight clinical polysomnography in a sleep laboratory; a randomly selected subset of participants also wore either the Ambulatory Monitoring Inc. Motionlogger Sleep Watch (AMI) or Phillips-Respironics Mini-Mitter Spectrum (PRMM). PARTICIPANTS: 63 youth (32 females, 31 males), ages 3-17 years (mean 9.7 years, SD 4.6 years). MEASUREMENTS: Both "Normal" and "Sensitive" sleep-recording Fitbit Ultra modes were examined. Outcome variables included total sleep time (TST), wake after sleep onset (WASO), and sleep efficiency (SE). Primary analyses examined the differences between Fitbit Ultra and PSG using repeated-measures ANCOVA, with epoch-by-epoch comparisons between Fitbit Ultra and PSG used to determine sensitivity, specificity, and accuracy. Intra-device reliability, differences between Fitbit Ultra and actigraphy, and differences by both developmental age group and sleep disordered breathing (SDB) status were also examined. RESULTS: Compared to PSG, the Normal Fitbit Ultra mode demonstrated good sensitivity (0.86) and accuracy (0.84), but poor specificity (0.52); conversely, the Sensitive Fitbit Ultra mode demonstrated adequate specificity (0.79), but inadequate sensitivity (0.70) and accuracy (0.71). Compared to PSG, the Fitbit Ultra significantly overestimated TST (41 min) and SE (8%) in Normal mode, and underestimated TST (105 min) and SE (21%) in Sensitive mode. Similar differences were found between Fitbit Ultra (both modes) and both brands of actigraphs. CONCLUSIONS: Despite its low cost and ease of use for consumers, neither sleep-recording mode of the Fitbit Ultra accelerometer provided clinically comparable results to PSG. Further, pediatric sleep researchers and clinicians should be cautious about substituting these devices for validated actigraphs, with a significant risk of either overestimating or underestimating outcome data including total sleep time and sleep efficiency.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
The role and validity of actigraphy in sleep medicine: an update
Sadeh, A. (2011) · Sleep Medicine Reviews · doi:10.1016/j.smrv.2010.10.001 · Cited by 1,415
Characterizing Sleep in Children with Autism Spectrum Disorders: A Multidimensional Approach
Malow, B. A., Marzec, M. L., McGrew, S. G., Wang, L., Henderson, L. M., & Stone, W. L. (2006) · Sleep · doi:10.1093/sleep/29.12.1563 · Cited by 485
Movement toward a novel activity monitoring device
Montgomery-Downs, H. E., Insana, S. P., & Bond, J. A. (2012) · Sleep and Breathing · doi:10.1007/s11325-011-0585-y · Cited by 301
Self-citation
Cited by
Systematic review of the validity and reliability of consumer-wearable activity trackers
Evenson, K. R., Goto, M. M., & Furberg, R. D. (2015) · International Journal of Behavioral Nutrition and Physical Activity · doi:10.1186/s12966-015-0314-1 · Cited by 1,232
Assessment of the cortisol awakening response: Expert consensus guidelines
Stalder, T., Kirschbaum, C., Kudielka, B. M., Adam, E. K., Pruessner, J. C., Wüst, S., Dockray, S., Smyth, N., Evans, P., Hellhammer, D. H., et al. (2016) · Psychoneuroendocrinology · doi:10.1016/j.psyneuen.2015.10.010 · Cited by 967
Wearable Sleep Technology in Clinical and Research Settings
DE ZAMBOTTI, M., CELLINI, N., GOLDSTONE, A., COLRAIN, I. M., & BAKER, F. C. (2019) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0000000000001947 · Cited by 564
Accuracy of Wristband Fitbit Models in Assessing Sleep: Systematic Review and Meta-Analysis
Haghayegh, S., Khoshnevis, S., Smolensky, M. H., Diller, K. R., & Castriotta, R. J. (2019) · Journal of Medical Internet Research · doi:10.2196/16273 · Cited by 446
Performance of seven consumer sleep-tracking devices compared with polysomnography
Chinoy, E. D., Cuellar, J. A., Huwa, K. E., Jameson, J. T., Watson, C. H., Bessman, S. C., Hirsch, D. A., Cooper, A. D., Drummond, S. P. A., & Markwald, R. R. (2021) · Sleep · doi:10.1093/sleep/zsaa291 · Cited by 433
A validation study of Fitbit Charge 2™ compared with polysomnography in adults
de Zambotti, M., Goldstone, A., Claudatos, S., Colrain, I. M., & Baker, F. C. (2018) · Chronobiology International · doi:10.1080/07420528.2017.1413578 · Cited by 413
A survey on sleep assessment methods
Ibáñez, V., Silva, J., & Cauli, O. (2018) · PeerJ · doi:10.7717/peerj.4849 · Cited by 316
Xie, J., Wen, D., Liang, L., Jia, Y., Gao, L., & Lei, J. (2018) · JMIR mHealth and uHealth · doi:10.2196/mhealth.9754 · Cited by 310
The Sleep of the Ring: Comparison of the ŌURA Sleep Tracker Against Polysomnography
de Zambotti, M., Rosas, L., Colrain, I. M., & Baker, F. C. (2019) · Behavioral Sleep Medicine · doi:10.1080/15402002.2017.1300587 · Cited by 287
Real-time assessment of suicidal thoughts and behaviors
Kleiman, E. M., & Nock, M. K. (2018) · Current Opinion in Psychology · doi:10.1016/j.copsyc.2017.07.026 · Cited by 239
de Zambotti, M., Baker, F. C., Willoughby, A. R., Godino, J. G., Wing, D., Patrick, K., & Colrain, I. M. (2016) · Physiology & Behavior · doi:10.1016/j.physbeh.2016.03.006 · Cited by 222
“Earlier Fitbit devices showed high sensitivity and poor specificity (98% and 20% respectively, in adults [26] and 87% and 52% respectively, in the pediatric population [27].”
BackgroundMethodResultInfluentialOrthosomnia: are some patients taking the quantified self too far?
Baron, K. G., Abbott, S., Jao, N., Manalo, N., & Mullen, R. (2017) · Journal of Clinical Sleep Medicine · doi:10.5664/jcsm.6472 · Cited by 188
Fonseca, P., Weysen, T., Goelema, M. S., Møst, E. I. S., Radha, M., Lunsingh Scheurleer, C., van den Heuvel, L., & Aarts, R. M. (2017) · SLEEP · doi:10.1093/sleep/zsx097 · Cited by 148
Kang, S.-G., Kang, J. M., Ko, K.-P., Park, S.-C., Mariani, S., & Weng, J. (2017) · Journal of Psychosomatic Research · doi:10.1016/j.jpsychores.2017.03.009 · Cited by 146
Wearable Activity Tracker Use Among Australian Adolescents: Usability and Acceptability Study
Ridgers, N. D., Timperio, A., Brown, H., Ball, K., Macfarlane, S., Lai, S. K., Richards, K., Mackintosh, K. A., McNarry, M. A., Foster, M., et al. (2018) · JMIR mHealth and uHealth · doi:10.2196/mhealth.9199 · Cited by 125
Moreno-Pino, F., Porras-Segovia, A., López-Esteban, P., Artés, A., & Baca-García, E. (2019) · Journal of Clinical Sleep Medicine · doi:10.5664/jcsm.8032 · Cited by 112
Godino, J. G., Wing, D., de Zambotti, M., Baker, F. C., Bagot, K., Inkelis, S., Pautz, C., Higgins, M., Nichols, J., Brumback, T., et al. (2020) · PLoS ONE · doi:10.1371/journal.pone.0237719 · Cited by 107
“Our findings are also consistent with other validation studies examining the use of Fitbit devices in healthy adolescent [15,39] and adult samples.”
ResultLiang, Z., & Chapa-Martell, M. A. (2019) · JMIR mHealth and uHealth · doi:10.2196/13384 · Cited by 76
“In response to this need, many studies have examined the accuracy of popular sleep trackers compared with medical devices in terms of aggregated sleep metrics, including TST, wake after sleep onset (WASO), sleep efficiency (SE), and sleep stages, that is, light sleep, deep sleep, and rapid eye movement (REM) sleep [18…”
Lee, P. H., & Suen, L. K. P. (2017) · Sleep And Breathing · doi:10.1007/s11325-016-1406-0 · Cited by 60
The Eight Hour Sleep Challenge During Final Exams Week
Scullin, M. K. (2019) · Teaching of Psychology · doi:10.1177/0098628318816142 · Cited by 36
Ghorbani, S., Golkashani, H. A., Chee, N. I., Teo, T. B., Dicom, A. R., Yilmaz, G., Leong, R. L., Ong, J. L., & Chee, M. W. (2022) · Nature and Science of Sleep · doi:10.2147/nss.s359789 · Cited by 36
The 8–Hour Challenge: Incentivizing Sleep during End–of–Term Assessments
King, E., Mobley, C., & Scullin, M. K. (2019) · Journal of Interior Design · doi:10.1111/joid.12135 · Cited by 23
Alterations in Daytime and Nighttime Activity in Piglets after Focal and Diffuse Brain Injury
Olson, E., Badder, C., Sullivan, S., Smith, C., Propert, K., & Margulies, S. S. (2016) · Journal of Neurotrauma · doi:10.1089/neu.2015.4085 · Cited by 16
Clevenger, K. A., Molesky, M. J., Vusich, J., & Montoye, A. H. K. (2019) · Measurement in Physical Education and Exercise Science · doi:10.1080/1091367x.2019.1577737 · Cited by 13
Metadata
- Authors
- Meltzer, L. J., Hiruma, L. S., Avis, K., Montgomery-Downs, H., & Valentin, J.
- Venue
- Sleep
- Publisher
- Oxford University Press (OUP)
- Published
- 2015-08-01
- Volume
- 38
- Issue
- 8
- Pages
- 1323-1330
- ISSN
- 0161-8105 (ISSN-L)
- 1550-9109
- OpenAlex
- W2425111601
- Cited by
- 228
- References
- 4
- FWCI
- 37.70
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.