Cited by 148Non-Invasive Vital Sign MonitoringSleep and related disordersHeart Rate Variability and Autonomic Control

Validation of photoplethysmography-based sleep staging compared with polysomnography in healthy middle-aged adults

Fonseca, Pedro, Weysen, Tim, Goelema, Maaike S., Møst, Els I.S., Radha, Mustafa, Lunsingh Scheurleer, Charlotte, van den Heuvel, Leonie, Aarts, Ronald M.·2017·SLEEP

Abstract

Study Objectives: To compare the accuracy of automatic sleep staging based on heart rate variability measured from photoplethysmography (PPG) combined with body movements measured with an accelerometer, with polysomnography (PSG) and actigraphy. Methods: Using wrist-worn PPG to analyze heart rate variability and an accelerometer to measure body movements, sleep stages and sleep statistics were automatically computed from overnight recordings. Sleep-wake, 4-class (wake/N1 + N2/N3/REM) and 3-class (wake/NREM/REM) classifiers were trained on 135 simultaneously recorded PSG and PPG recordings of 101 healthy participants and validated on 80 recordings of 51 healthy middle-aged adults. Epoch-by-epoch agreement and sleep statistics were compared with actigraphy for a subset of the validation set. Results: The sleep-wake classifier obtained an epoch-by-epoch Cohen's κ between PPG and PSG sleep stages of 0.55 ± 0.14, sensitivity to wake of 58.2 ± 17.3%, and accuracy of 91.5 ± 5.1%. κ and sensitivity were significantly higher than with actigraphy (0.40 ± 0.15 and 45.5 ± 19.3%, respectively). The 3-class classifier achieved a κ of 0.46 ± 0.15 and accuracy of 72.9 ± 8.3%, and the 4-class classifier, a κ of 0.42 ± 0.12 and accuracy of 59.3 ± 8.5%. Conclusions: The moderate epoch-by-epoch agreement and, in particular, the good agreement in terms of sleep statistics suggest that this technique is promising for long-term sleep monitoring, although more evidence is needed to understand whether it can complement PSG in clinical practice. It also offers an improvement in sleep/wake detection over actigraphy for healthy individuals, although this must be confirmed on a larger, clinical population.

Integrity signals

Registry

Crossref · 10.1093/sleep/zsx097

Cites

50 of 50 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • PPG accuracy issues potentially affect health-related outcomes that rely on PPG, including sleep duration, sleep architecture, diagnosis of sleep apnea, long-term sleep patterns, and other sleep disorders.

    “This potentially affects health-related outcomes that rely on PPG including a host of sleep-related indices such as sleep duration, architecture [8], diagnosis of sleep apnea [9], long-term sleep patterns, and other sleep disorders [10].”

Cites

1 retracted

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Fonseca, P., Weysen, T., Goelema, M. S., Møst, E. I. S., Radha, M., Lunsingh Scheurleer, C., van den Heuvel, L., & Aarts, R. M.
Affiliations
Eindhoven University of Technology (NL)
Venue
SLEEP
Published
2017-06-16
Volume
40
Issue
7
ISSN
  • 0161-8105 (ISSN-L)
  • 1550-9109
OpenAlex
W2625272325
Cited by
148
References
50
Citations by year
2026: 9 · 2025: 17 · 2024: 14 · 2023: 19 · 2022: 14 · 2021: 30 · 2020: 20 · 2019: 17 · 2018: 7 · 2017: 1
FWCI
5.55
Type
journal article
Language
en
Open access
closed
Locations
  • SLEEP (publishedVersion)
  • PubMed (publishedVersion)
  • TU/e Research Portal (submittedVersion)
Topics
  • Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
  • Social Sciences › Psychology › Experimental and Cognitive Psychology › Sleep and related disorders
  • Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Heart Rate Variability and Autonomic Control
Keywords
photoplethysmography, sleep stage classification, heart rate variability, accelerometer, actigraphy, polysomnography, sleep-wake detection, long-term sleep monitoring, middle-aged adults
MeSH terms
Adult, Female, Heart Rate, Humans, Male, Middle Aged, Movement, Sleep Stages, Wakefulness, Wrist, Photoplethysmography, Polysomnography, Actigraphy, Healthy Volunteers

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review