Spectrum Bias in the Evaluation of Diagnostic Tests: Lessons from the Rapid Dipstick Test for Urinary Tract Infection
The DOI matches its Crossref record; 14 of the 14 references it cites were found in a registry or an index.
Abstract
OBJECTIVE: To determine if the leukocyte esterase and bacterial nitrite rapid dipstick test for urinary tract infection (UTI) is susceptible to spectrum bias (when a diagnostic test has different sensitivities or specificities in patients with different clinical manifestations of the disease for which the test is intended). DESIGN: Cross-sectional study. PATIENTS: A total of 366 consecutive adult patients in whom clinicians performed urinalysis to diagnose or exclude UTI. SETTING: An urban emergency department and walk-in clinic. MEASUREMENTS: After the patient encounter, but before dipstick test or culture was done, clinicians recorded the signs and symptoms that were the basis for suspecting UTI and for performing a urinalysis and an estimate of the probability of UTI based on the clinical evaluation. For all patients who received urinalysis, dipstick tests and culture were done in the clinical microbiology laboratory by medical technologists blinded to clinical evaluation. Sensitivity for the dipstick was calculated using a positive result in either leukocyte esterase or bacterial nitrite, or both, as the criterion for a positive dipstick, and greater than 10(5) CFU/mL for a positive culture. RESULTS: In the 107 patients with a high (greater than 50%) prior probability of UTI, who had many characteristic UTI symptoms, the sensitivity of the test was excellent (0.92; 95% CI, 0.82 to 0.98). In the 259 patients with a low (less than or equal to 50%) prior probability of UTI, the sensitivity of the test was poor (0.56; CI, 0.03 to 0.79). CONCLUSIONS: The leukocyte esterase and bacterial nitrite dipstick test for UTI is susceptible to spectrum bias, which may be responsible for differences in the test's sensitivity reported in previous studies. As a more general principle, diagnostic tests may have different sensitivities or specificities in different parts of the clinical spectrum of the disease they purport to identify or exclude, but studies evaluating such tests rarely report sensitivity and specificity in subgroups defined by clinical symptoms. When diagnostic tests are evaluated, information about symptoms in the patients recruited for study should be included, and analyses should be done within appropriate clinical subgroups so that clinicians may decide if reported sensitivities and specificities are applicable to their patients.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Problems of Spectrum and Bias in Evaluating the Efficacy of Diagnostic Tests
Ransohoff, D. F., & Feinstein, A. R. (1978) · New England Journal of Medicine · doi:10.1056/nejm197810262991705 · Cited by 1,734
Self-citationSelection and interpretation of diagnostic tests and procedures
Griner, P. F., Mayewski, R. J., Mushlin, A. I., & Greenland, P. (1981) · Annals of Internal Medicine · Cited by 595
Levy, D., Labib, S. B., Anderson, K. M., Christiansen, J. C., Kannel, W. B., & Castelli, W. P. (1990) · Circulation · doi:10.1161/01.cir.81.3.815 · Cited by 531
FLETCHER, R. H. (1986) · Annals of Internal Medicine · doi:10.7326/0003-4819-104-1-66 · Cited by 473
Factors affecting sensitivity and specificity of exercise electrocardiography
Hlatky, M. A., Pryor, D. B., Harrell, F. E., Califf, R. M., Mark, D. B., & Rosati, R. A. (1984) · The American Journal of Medicine · doi:10.1016/0002-9343(84)90437-6 · Cited by 371
The Diagnostic Accuracy of Rapid Dipstick Tests to Predict Urinary Tract Infection
Hurlbut, T. A., & Littenberg, B. (1991) · American Journal of Clinical Pathology · doi:10.1093/ajcp/96.5.582 · Cited by 179
Komaroff, A. L. (1984) · New England Journal of Medicine · doi:10.1056/nejm198402093100607 · Cited by 123
Factors affecting sensitivity and specificity of a diagnostic test: the exercise thallium scintigram
Detrano, R., Jánosi, A., Lyons, K. P., Marcondes, G., Abbassi, N., & Froelicher, V. F. (1988) · The American Journal of Medicine · doi:10.1016/0002-9343(88)90107-6 · Cited by 120
Quantitative definition of bacteriuria
Platt, R. G. (1983) · The American Journal of Medicine · doi:10.1016/0002-9343(83)90072-4 · Cited by 112
Dipstick urinalysis screening of asymptomatic adults for urinary tract disorders. II. Bacteriuria
Pels, R. J. (1989) · JAMA · doi:10.1001/jama.262.9.1221 · Cited by 106
Cited by
Receiver-operating characteristic (ROC) plots: a fundamental evaluation tool in clinical medicine
Zweig, M. H., & Campbell, G. (1993) · Clinical Chemistry · doi:10.1093/clinchem/39.4.561 · Cited by 6,569
Moher, D., Schulz, K. F., & Altman, D. G. (2001) · BMC Medical Research Methodology · doi:10.1186/1471-2288-1-2 · Cited by 2,755
STARD 2015 guidelines for reporting diagnostic accuracy studies: explanation and elaboration
Cohen, J. F., Korevaar, D. A., Altman, D. G., Bruns, D. E., Gatsonis, C. A., Hooft, L., Irwig, L., Levine, D., Reitsma, J. B., de Vet, H. C. W., et al. (2016) · BMJ Open · doi:10.1136/bmjopen-2016-012799 · Cited by 2,570
Simon, L., Gauvin, F., Amre, D. K., Saint-Louis, P., & Lacroix, J. (2004) · Clinical Infectious Diseases · doi:10.1086/421997 · Cited by 1,787
Assessing the Generalizability of Prognostic Information
Justice, A. C., Covinsky, K. E., & Berlin, J. A. (1999) · Annals of Internal Medicine · doi:10.7326/0003-4819-130-6-199903160-00016 · Cited by 1,160
The STARD Statement for Reporting Studies of Diagnostic Accuracy: Explanation and Elaboration
Bossuyt, P. M., Reitsma, J. B., Bruns, D. E., Gatsonis, C. A., Glasziou, P. P., Irwig, L. M., Moher, D., Rennie, D., de Vet, H. C. W., & Lijmer, J. G. (2003) · Annals of Internal Medicine · doi:10.7326/0003-4819-138-1-200301070-00012-w1 · Cited by 1,124
Clinical Epidemiology: The Architecture of Clinical Research.
(1985) · Annals of Internal Medicine · doi:10.7326/0003-4819-103-4-649_2 · Cited by 949
Sources of Variation and Bias in Studies of Diagnostic Accuracy: A Systematic Review
Whiting, P., Rutjes, A. W. S., Reitsma, J. B., Glas, A. S., Bossuyt, P. M. M., & Kleijnen, J. (2004) · Annals of Internal Medicine · doi:10.7326/0003-4819-140-3-200402030-00010 · Cited by 798
Guidelines for Meta-analyses Evaluating Diagnostic Tests
Irwig, L., Tosteson, A. N. A., Gatsonis, C., Lau, J., Colditz, G., Chalmers, T. C., & Mosteller, F. (1994) · Annals of Internal Medicine · doi:10.7326/0003-4819-120-8-199404150-00008 · Cited by 753
Wainner, R. S., Fritz, J. M., Irrgang, J. J., Boninger, M. L., Delitto, A., & Allison, S. (2003) · Spine · doi:10.1097/00007632-200301010-00014 · Cited by 598
The urine dipstick test useful to rule out infections. A meta-analysis of the accuracy
Devillé, W. L., Yzermans, J. C., van Duijn, N. P., Bezemer, P. D., van der Windt, D. A., & Bouter, L. M. (2004) · BMC Urology · doi:10.1186/1471-2490-4-4 · Cited by 519
“Results Literature search The search strategy identified 220 publications, of which 70 [29-98] met the inclusion and exclusion criteria.”
BackgroundCase–Control and Two-Gate Designs in Diagnostic Accuracy Studies
Rutjes, A. W., Reitsma, J. B., Vandenbroucke, J. P., Glas, A. S., & Bossuyt, P. M. (2005) · Clinical Chemistry · doi:10.1373/clinchem.2005.048595 · Cited by 501
Rules of evidence for cancer molecular-marker discovery and validation
Ransohoff, D. F. (2004) · Nature Reviews Cancer · doi:10.1038/nrc1322 · Cited by 498
BRENNER, H., & GEFELLER, O. (1997) · Statistics in Medicine · doi:10.1002/(sici)1097-0258(19970515)16:9<981::aid-sim510>3.0.co;2-n · Cited by 488
Diagnostic test accuracy may vary with prevalence: implications for evidence-based diagnosis
Leeflang, M. M. G., Bossuyt, P. M. M., & Irwig, L. (2009) · Journal of Clinical Epidemiology · doi:10.1016/j.jclinepi.2008.04.007 · Cited by 482
How to Use an Article About a Diagnostic Test
Scales, C. D., Dahm, P., Sultan, S., Campbell-Scherer, D., & Devereaux, P. J. (2008) · Journal of Urology · doi:10.1016/j.juro.2008.04.026 · Cited by 456
Exploring sources of heterogeneity in systematic reviews of diagnostic tests
Lijmer, J. G., Bossuyt, P. M. M., & Heisterkamp, S. H. (2002) · Statistics in Medicine · doi:10.1002/sim.1185 · Cited by 446
Romagnuolo, J., Bardou, M., Rahme, E., Joseph, L., Reinhold, C., & Barkun, A. N. (2003) · Annals of Internal Medicine · doi:10.7326/0003-4819-139-7-200310070-00006 · Cited by 445
Cohen, J. F., Chalumeau, M., Cohen, R., Korevaar, D. A., Khoshnood, B., & Bossuyt, P. M. M. (2015) · Journal of Clinical Epidemiology · doi:10.1016/j.jclinepi.2014.09.005 · Cited by 413
Diagnostic Precision of Fecal Calprotectin for Inflammatory Bowel Disease and Colorectal Malignancy
von Roon, A. C., Karamountzos, L., Purkayastha, S., Reese, G. E., Darzi, A. W., Teare, J. P., Paraskeva, P., & Tekkis, P. P. (2007) · The American Journal of Gastroenterology · doi:10.1111/j.1572-0241.2007.01126.x · Cited by 401
Assessing the quality of research.
Glasziou, P., Vandenbroucke, J., & Chalmers, I. (2004) · BMJ · doi:10.1136/bmj.328.7430.39 · Cited by 391
Development and validation of methods for assessing the quality of diagnostic accuracy studies
Whiting, P., Rutjes, A., Dinnes, J., Reitsma, J., Bossuyt, P., & Kleijnen, J. (2004) · Health Technology Assessment · doi:10.3310/hta8250 · Cited by 372
van Westreenen, H. L., Westerterp, M., Bossuyt, P. M. M., Pruim, J., Sloof, G. W., van Lanschot, J. J. B., Groen, H., & Plukker, J. T. M. (2004) · Journal of Clinical Oncology · doi:10.1200/jco.2004.01.083 · Cited by 370
Spectrum Bias or Spectrum Effect? Subgroup Variation in Diagnostic Test Evaluation
Mulherin, S. A., & Miller, W. C. (2002) · Annals of Internal Medicine · doi:10.7326/0003-4819-137-7-200210010-00011 · Cited by 327
Urinary Tract Infections in Older Women: A Clinical Review
Mody, L., & Juthani-Mehta, M. (2014) · JAMA · doi:10.1001/jama.2014.303 · Cited by 324
McDowell, I., Kristjansson, B., Hill, G. B., & Hébert, R. (1997) · Journal of Clinical Epidemiology · doi:10.1016/s0895-4356(97)00060-7 · Cited by 307
Bastiaannet, E., Groen, H., Jager, P. L., Cobben, D. C. P., van der Graaf, W. T. A., Vaalburg, W., & Hoekstra, H. J. (2004) · Cancer Treatment Reviews · doi:10.1016/j.ctrv.2003.07.004 · Cited by 294
Thomas, K. E., Hasbun, R., Jekel, J., & Quagliarello, V. J. (2002) · Clinical Infectious Diseases · doi:10.1086/340979 · Cited by 287
A systematic review classifies sources of bias and variation in diagnostic test accuracy studies
Whiting, P. F., Rutjes, A. W. S., Westwood, M. E., & Mallett, S. (2013) · Journal of Clinical Epidemiology · doi:10.1016/j.jclinepi.2013.05.014 · Cited by 283
Jonas, D. E., Amick, H. R., Feltner, C., Weber, R. P., Arvanitis, M., Stine, A., Lux, L., & Harris, R. P. (2017) · JAMA · doi:10.1001/jama.2016.19635 · Cited by 267
Henderson, A. R. (1993) · Annals of Clinical Biochemistry: International Journal of Laboratory Medicine · doi:10.1177/000456329303000601 · Cited by 258
Irwig, L. (2002) · BMJ · doi:10.1136/bmj.324.7338.669 · Cited by 246
Screening Tests for Urinary Tract Infection in Children: A Meta-analysis
Gorelick, M. H., & Shaw, K. N. (1999) · Pediatrics · doi:10.1542/peds.104.5.e54 · Cited by 243
Dermoscopy, with and without visual inspection, for diagnosing melanoma in adults
Dinnes, J., Deeks, J. J., Chuchu, N., Ferrante di Ruffano, L., Matin, R. N., Thomson, D. R., Wong, K. Y., Aldridge, R. B., Abbott, R., Fawzy, M., et al. (2018) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd011902.pub2 · Cited by 232
Diagnostic Accuracy of Urine Dipsticks for Detection of Albuminuria in the General Community
White, S. L., Yu, R., Craig, J. C., Polkinghorne, K. R., Atkins, R. C., & Chadban, S. J. (2011) · American Journal of Kidney Diseases · doi:10.1053/j.ajkd.2010.12.026 · Cited by 225
“This is a critical gap in our understanding of the potential dynamics of proposed dipstick-based mass screening for proteinuria because test performance varies across the patient spectrum.(19,20) Here, we evaluate the test performance of urine dipsticks for the detection of proteinuria in a large population-based coho…”
MethodPredicting urinary tract infections in the emergency department with machine learning
Taylor, R. A., Moore, C. L., Cheung, K.-H., & Brandt, C. (2018) · PLOS ONE · doi:10.1371/journal.pone.0194085 · Cited by 224
Vroomen, P. C. A. J. (2002) · Journal of Neurology, Neurosurgery & Psychiatry · doi:10.1136/jnnp.72.5.630 · Cited by 214
Gupta, K., Grigoryan, L., & Trautner, B. (2017) · Annals of Internal Medicine · doi:10.7326/aitc201710030 · Cited by 210
Taylor, M. R., & Lalani, N. (2013) · Academic Emergency Medicine · doi:10.1111/acem.12150 · Cited by 205
Leite, M. T., Rao, H. L., Zangwill, L. M., Weinreb, R. N., & Medeiros, F. A. (2011) · Ophthalmology · doi:10.1016/j.ophtha.2010.11.029 · Cited by 200
Context Bias: A Problem in Diagnostic Radiology
Egglin, T. K. P. (1996) · JAMA · doi:10.1001/jama.1996.03540210060035 · Cited by 192
Moons, K. G. M., van Es, G.-A., Deckers, J. W., Habbema, J. D. F., & Grobbee, D. E. (1997) · Epidemiology · doi:10.1097/00001648-199701000-00002 · Cited by 189
Vroomen, P. C. A. J., de Krom, M. C. T. F. M., & Knottnerus, J. A. (1999) · Journal of Neurology · doi:10.1007/s004150050480 · Cited by 168
Medeiros, F. A., Zangwill, L. M., Bowd, C., Sample, P. A., & Weinreb, R. N. (2006) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.05-1133 · Cited by 162
“Diagnostic tests tend to be more sensitive in advanced stages of the disease, and measures of diagnostic accuracy obtained from studies that include only patients with moderate or severe disease may not be applicable to patients in the early stage or suspected of having the disease.(2,3) Therefore, a study evaluating…”
Dipstick urinalysis and the accuracy of the clinical diagnosis of urinary tract infection
Sultana, R. V., Zalstein, S., Cameron, P., & Campbell, D. (2001) · The Journal of Emergency Medicine · doi:10.1016/s0736-4679(00)00290-0 · Cited by 72
Romme, J. J. C. M., van Dijk, N., Boer, K. R., Bossuyt, P. M. M., Wieling, W., & Reitsma, J. B. (2009) · European Heart Journal · doi:10.1093/eurheartj/ehp314 · Cited by 55
LEMAN, P. (2002) · European Journal of Emergency Medicine · doi:10.1097/00063110-200206000-00008 · Cited by 50
Winquist, A. G., Orrico, M. A., & Peterson, L. R. (1997) · American Journal of Clinical Pathology · doi:10.1093/ajcp/108.5.515 · Cited by 22
Metadata
- Authors
- Lachs, M. S., Nachamkin, I., Edelstein, P. H., Goldman, J., Feinstein, A. R., & Schwartz, J. S.
- Venue
- Annals of Internal Medicine
- Publisher
- American College of Physicians
- Published
- 1992-07-15
- Volume
- 117
- Issue
- 2
- Pages
- 135-140
- ISSN
- 0003-4819 (ISSN-L)
- 1539-3704
- OpenAlex
- W1985408831
- Cited by
- 261
- References
- 14
- FWCI
- 6.71
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.