QUADAS-2: A Revised Tool for the Quality Assessment of Diagnostic Accuracy Studies
Open accessThe DOI matches its Crossref record; 18 of the 18 references it cites were found in a registry or an index; none of the 21 sources its claims cite is checked for support yet.
Abstract
In 2003, the QUADAS tool for systematic reviews of diagnostic accuracy studies was developed. Experience, anecdotal reports, and feedback suggested areas for improvement; therefore, QUADAS-2 was developed. This tool comprises 4 domains: patient selection, index test, reference standard, and flow and timing. Each domain is assessed in terms of risk of bias, and the first 3 domains are also assessed in terms of concerns regarding applicability. Signalling questions are included to help judge risk of bias. The QUADAS-2 tool is applied in 4 phases: summarize the review question, tailor the tool and produce review-specific guidance, construct a flow diagram for the primary study, and judge bias and applicability. This tool will allow for more transparent rating of bias and applicability of primary diagnostic accuracy studies.
Overview
CoChat Summary
TL;DR
QUADAS-2 is a revised tool for assessing risk of bias and applicability in diagnostic accuracy studies, developed through a 4-stage evidence-based consensus process. It replaces the original QUADAS “yes/no/unclear” quality rating with domain-level judgments of low, high, or unclear risk of bias and concerns about applicability.
Key findings
- QUADAS-2 separates “quality” into risk of bias and concerns regarding applicability, defining quality as the degree to which diagnostic accuracy estimates avoided bias and the extent to which primary studies are applicable to the review question.
- The tool has 4 key domains—patient selection, index test, reference standard, and flow and timing—with the first 3 also assessed for applicability; it is completed in 4 phases and uses signaling questions to help judge risk of bias.
- Development drew on 4 reviews: 54 diagnostic accuracy reviews published between 2007 and 2009, structured feedback from 64 systematic reviewers who had used QUADAS, 101 studies on sources of bias and variation, and 8 studies evaluating QUADAS; a 1-day consensus meeting had 24 attendees, and piloting occurred in 5 reviews.
- Interrater reliability varied considerably, with better agreement on applicability than on risk of bias; all participants preferred QUADAS-2 to the original tool, but the authors could not currently include criteria for studies comparing multiple index tests because the evidence base was insufficient.
Methods
- Tool development followed Moher and colleagues’ 4-stage approach: define the scope, review the evidence base, hold a face-to-face consensus meeting, and refine through piloting.
- A steering group of 9 experts set the scope; the consensus meeting was held on 21 September 2010 in Birmingham, United Kingdom, with 24 attendees who split into groups of 4 to 6 participants; multiple rounds of piloting used online questionnaires and other feedback, including pairs of reviewers piloting QUADAS-2 in 5 reviews.
- No primary statistical analysis was reported; the work synthesized evidence reviews, consensus decisions, and pilot feedback to produce and refine the tool.
Limitations
- Stated: the authors decided they cannot currently include criteria for assessing studies that compare multiple index tests within QUADAS-2 because of the limited evidence base on risk of bias and sources of variation in such studies, and they plan future work on this topic.
- Stated: piloting showed poor interrater reliability and problems applying the domain on comparative accuracy studies; interrater reliability varied considerably overall, with better agreement on applicability than on risk of bias.
- Evident from the text: full details of the 4 evidence reviews were to be published separately, and the main text reports no quantitative reliability estimates, referring instead to an Appendix Table.
Model-written summary. Check it against the paper before relying on it.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
0 Valid · 0 Not valid · 16 Not checked · 24 Own results and interpretations
In the paper
“In a review on anti-cyclic citrullinated peptide antibodies for diagnosing rheumatoid arthritis (10), we found that some studies enrolled consecutive participants with confirmed diagnoses. In these studies, testing for anticyclic citrullinated peptide antibody showed greater sensitivity than in studies that included patients with suspected disease but an unconfirmed diagnosis (that is, difficult-t”
§ QUADAS-2: A Revised Tool for the Quality Assessment of Diagnostic Accuracy Studies > Signaling question 2: Was a case-control design avoided? Signaling question 3: Did the study avoid inappropriate exclusions?
What the sources say
- Not matchedcites [10]
The reference list we hold has no entry [10].
plainstates an association- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Not matched
A statement the paper makes itself — it cites no source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“Studies that make inappropriate exclusions (for example, not including”
§ QUADAS-2: A Revised Tool for the Quality Assessment of Diagnostic Accuracy Studies > Signaling question 2: Was a case-control design avoided? Signaling question 3: Did the study avoid inappropriate exclusions?
hedgedstates a possible cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
None of the sources cited for this claim could be matched to a paper, so there is nothing to check it against.
In the paper
“Because the accuracy of a test may depend on where it will be used in the diagnostic pathway, review authors are asked to describe patients in terms of setting, intended use of the index test, patient presentation, and previous testing (8,9).”
§ QUADAS-2: A Revised Tool for the Quality Assessment of Diagnostic Accuracy Studies > Phase 1: Review Question
What the sources say
- Not matchedcites [8]
The reference list we hold has no entry [8].
- Not matchedcites [9]
The reference list we hold has no entry [9].
hedgedstates a possible cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Not matched
In the paper
“Development of QUADAS-2 was based on the 4-stage approach proposed by Moher and colleagues (4): define the scope, review the evidence base, hold a face-to-face consensus meeting, and refine the tool through piloting.”
§ QUADAS-2: A Revised Tool for the Quality Assessment of Diagnostic Accuracy Studies > METHODS
What the sources say
- Not matchedcites [4]
The reference list we hold has no entry [4].
plainstates a cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: unclear — It is unclear whether the paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Not matched
None of the sources cited for this claim could be matched to a paper, so there is nothing to check it against.
In the paper
“Studies enrolling participants with known disease and a control group without the condition may similarly exaggerate diagnostic accuracy (7,11).”
§ QUADAS-2: A Revised Tool for the Quality Assessment of Diagnostic Accuracy Studies > Signaling question 2: Was a case-control design avoided? Signaling question 3: Did the study avoid inappropriate exclusions?
What the sources say
- Not matchedcites [7]
The reference list we hold has no entry [7].
- Not matchedcites [11]
The reference list we hold has no entry [11].
hedgedstates a possible cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Not matched
10 more claims
Create a free account to see all 40 claims and every source verdict.
- Probably not a substantial claim. 19
- It may state two separate claims as one. 16
- The quote only partly states this claim. 2
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“We assessed the study-level risk of bias with the QUADAS-2 tool”
In the citing paper
“We developed a revised risk-of-bias assessment tool to address these issues, incorporate advances in assessment of risk of bias used in other recently developed tools, 9 10 and integrate recent developments in estimation of intervention effects from randomised trials. 11”
From RoB 2: a revised tool for assessing risk of bias in randomised trials (2019) · cites this paper as [10]
In the citing paper
“Two reviewers independently assessed the quality of the included studies with the Quality Assessment of Diagnostic Accuracy Studies (Quadas-2) [33].”
From High-standard predictive equations for estimating body composition using bioelectrical impedance analysis: a systematic review (2024) · cites this paper as [33]
In the citing paper
“The quality of the selected studies was rigorously assessed using the Checklist for Artificial Intelligence in Medical Imaging (CLAIM) alongside the Quality Assessment of Diagnostic Accuracy Studies-2 (QUADAS-2).23,24”
From Artificial Intelligence Detection and Segmentation Models: A Systematic Review and Meta-Analysis of Brain Tumors in Magnetic Resonance Imaging (2024) · cites this paper as [24]
In the citing paper
“The methodological quality of each selected study was assessed according to the Quality Assessment of Diagnostic Accuracy Studies (QUADAS-2) checklist [15]”
From The diagnostic accuracy of digital, infrared and mercury-in-glass thermometers in measuring body temperature: a systematic review and network meta-analysis (2021) · cites this paper as [15]
20 more claims about this paper
Create a free account to see every claim other papers make about this one.
Citations
Cites
The Cochrane Collaboration's tool for assessing risk of bias in randomised trials
Higgins, J. P. T., Altman, D. G., Gotzsche, P. C., Juni, P., Moher, D., Oxman, A. D., Savovic, J., Schulz, K. F., Weeks, L., Sterne, J. A. C., et al. (2011) · BMJ · doi:10.1136/bmj.d5928 · Cited by 33,817
Self-citationWhiting, P., Rutjes, A. W., Reitsma, J. B., Bossuyt, P. M., & Kleijnen, J. (2003) · BMC Medical Research Methodology · doi:10.1186/1471-2288-3-25 · Cited by 3,592
Self-citationThe Hazards of Scoring the Quality of Clinical Trials for Meta-analysis
Jüni, P. (1999) · JAMA · doi:10.1001/jama.282.11.1054 · Cited by 1,981
Empirical evidence of design-related bias in studies of diagnostic tests.
Lijmer, J. G. (1999) · JAMA · doi:10.1001/jama.282.11.1061 · Cited by 1,861 · cited 2×
“Studies enrolling participants with known disease and a control group without the condition may similarly exaggerate diagnostic accuracy (7, 11).”
BackgroundGuidance for Developers of Health Research Reporting Guidelines
Moher, D., Schulz, K. F., Simera, I., & Altman, D. G. (2010) · PLoS Medicine · doi:10.1371/journal.pmed.1000217 · Cited by 1,437
Systematic Reviews of Diagnostic Test Accuracy
Leeflang, M. M. G., Deeks, J. J., Gatsonis, C., & Bossuyt, P. M. M. (2008) · Annals of Internal Medicine · doi:10.7326/0003-4819-149-12-200812160-00008 · Cited by 1,124
Self-citationSources of Variation and Bias in Studies of Diagnostic Accuracy: A Systematic Review
Whiting, P., Rutjes, A. W. S., Reitsma, J. B., Glas, A. S., Bossuyt, P. M. M., & Kleijnen, J. (2004) · Annals of Internal Medicine · doi:10.7326/0003-4819-140-3-200402030-00010 · Cited by 798 · cited 4×
“The third review was an update on sources of bias and variation in diagnostic accuracy studies that included 101 studies (7).”
BackgroundInfluentialSelf-citationEvaluation of QUADAS, a tool for the quality assessment of diagnostic accuracy studies
Whiting, P. F., Weswood, M. E., Rutjes, A. W., Reitsma, J. B., Bossuyt, P. N., & Kleijnen, J. (2006) · BMC Medical Research Methodology · doi:10.1186/1471-2288-6-9 · Cited by 769
Self-citationLeeflang, M. M. G., Moons, K. G. M., Reitsma, J. B., & Zwinderman, A. H. (2008) · Clinical Chemistry · doi:10.1373/clinchem.2007.096032 · Cited by 346 · cited 1×
“Test performance is likely to be poorer in an independent sample of patients in whom the same threshold is used (12).”
BackgroundSelf-citationNo role for quality scores in systematic reviews of diagnostic accuracy studies
Whiting, P., Harbord, R., & Kleijnen, J. (2005) · BMC Medical Research Methodology · doi:10.1186/1471-2288-5-19 · Cited by 337
Self-citation
Cited by
Items 11,101–11,200 of 14,770
Junhai, Z., Fei, L., Jixiang, Z., Xie, H., Cheng, T., & Weiguo, D. (2024) · International Journal of Surgery · doi:10.1097/js9.0000000000001844 · Cited by 3
“The methodological quality of the included studies was assessed according to the Quality Assessment of Diagnostic Accuracy Studies 2 (QUADAS-2) guidelines [15] .”
Manea, M., Mărunțelu, I., & Constantinescu, I. (2024) · Journal of Clinical Medicine · doi:10.3390/jcm13133903 · Cited by 2
Diagnostic Value of Hepcidin in Sepsis: A Systematic Review and Meta-Analysis
Zhang, J., Zheng, Z., Ren, L., Wang, C., Li, Y., Hu, X., Zhang, J., Jing, X., & Jin, Y. (2024) · Journal of Intensive Care Medicine · doi:10.1177/08850666241267261 · Cited by 2
McGee, K., Jamil, M. S., Siegfried, N., Msimanga, B. R., Barr‐DiChiara, M., Baggaley, R. C., & Johnson, C. (2024) · PLOS Global Public Health · doi:10.1371/journal.pgph.0003588 · Cited by 2
“Studies reporting on usability and diagnostic accuracy were also assessed using the Quality Assessment of Diagnostic Accuracy Studies (QUADAS-2) tool [16].”
MethodLiu, J., Xia, G., Dai, Z., Wang, R., Feng, Z., Ma, G., Zeng, L., & He, X. (2024) · BMJ Open · doi:10.1136/bmjopen-2023-081015 · Cited by 2
Górska, A., & Tacconelli, E. (2024) · Studies in health technology and informatics · doi:10.3233/shti240427 · Cited by 4
Tebib, N., Monard, C., Rimmele, T. R., & Schneider, A. G. (2024) · Blood Purification · doi:10.1159/000541058 · Cited by 2
“We used the Quality Assessment of Diagnostic Accuracy Studies 2 (QUADAS-2) criteria for the appraisal of the methodological quality of every included study [15].”
Yazdi, S. N. M., Moradi, S. A., Rasoulighasemlouei, S., Parouei, F., & Hashemi, M. G. (2024) · World Journal of Nuclear Medicine · doi:10.1055/s-0044-1788794 · Cited by 2
Obradović, F. (2024) · Journal of Econometrics · doi:10.1016/j.jeconom.2024.105842 · Cited by 5
“Sensitivity of 90% is the only estimate which is not considered to be at high risk of bias according to the QUADAS-2 tool (Whiting et al., 2011).”
MethodHu, H., Hu, X., Liang, Z., Yang, W., Li, S., Li, D., & Cai, J. (2024) · Oncology Letters · doi:10.3892/ol.2024.14679 · Cited by 2
Methodology of systematic review in the health system
Mosadeghrad, A. M., & Isfahani, P. (2024) · Payesh (Health Monitor) Journal · doi:10.61186/payesh.23.4.507 · Cited by 2
Yuan, L., Hao, R., Zou, L., Zhai, D., Wang, J., & Jiao, R. (2024) · Acta Radiologica · doi:10.1177/02841851241275982 · Cited by 2
Muresu, N., Puci, M. V., Sotgiu, G., Sechi, I., Cossu, A., Usai, M., & Piana, A. F. (2024) · Healthcare · doi:10.3390/healthcare12191951 · Cited by 2
Villegas-Coronado, L., Villegas-Coronado, K., Urrea-Quezada, A., & Villegas‐Coronado, D. (2024) · Cureus · doi:10.7759/cureus.70647 · Cited by 3
“Quality assessment of the included studies was performed using the "Quality Assessment of Diagnostic Accuracy Studies 2" tool, which evaluates both the quality and risk of bias in diagnostic accuracy studies [18].”
MethodTian, T., & Ren, J. (2024) · Clinical and Translational Imaging · doi:10.1007/s40336-024-00661-0 · Cited by 2
“The quality assessment of included studies was analyzed carefully according to the QUADAS-2 (quality assessment of diagnostic performance studies-2) [13].”
Bao, C., Kuang, J., He, C., & Xu, H. (2024) · Irish Journal of Medical Science (1971 -) · doi:10.1007/s11845-024-03828-w · Cited by 2
“This was assessed in terms of risk of bias and applicability concerns based on the QUADAS-2 tool [29].”
Hughes-Davies, H., Ukwatte, U., Fanshawe, T. R., Roberts, N. W., Turner, P. J., Hayward, G., & Bird, C. (2024) · Ultrasound · doi:10.1177/1742271x241289726 · Cited by 2
“Both reviewers used the QUADAS-2 tool 21,22 to assess the quality of studies.”
Martín-Gutiérrez, G., Martín-Pérez, C., Rosa, J., Gutiérrez‐Carretero, E., de Alarcón, A., & Lepe, J. A. (2024) · Annals of Clinical Microbiology and Antimicrobials · doi:10.1186/s12941-024-00753-9 · Cited by 2
“The two investigators (GM-G and CM-P) independently scored the seven domains of the Revised Tool for the Quality Assessment of Diagnostic Accuracy Studies (QUADAS-2) [10] (Supplementary Table S2).”
MethodResultInfluentialAdriani, M., Saccomanno, M. F., Bergomi, A., Filippo, F. D., Daffara, V., & Milano, G. (2024) · Knee Surgery Sports Traumatology Arthroscopy · doi:10.1002/ksa.12531 · Cited by 2
“The tool consists of four key domains covering patient selection, index test, reference standard and fl ow of patients through the study [36].”
Agreement and Reliability of Transpalpebral Tonometers with Goldmann Applanation Tonometer
Jerrome, S., Joseph, S., Balasubramaniam, N., Arkaprava, M., Lakshmanan, P., Sundar, B., Kumaragurupari, T., Vidya, S., Senthilkumar, V. A., & Krishnadas, S. R. (2024) · Ophthalmology Glaucoma · doi:10.1016/j.ogla.2024.11.001 · Cited by 4
Moore, E., Gassasse, Z., & Quint, J. K. (2024) · BMJ Open · doi:10.1136/bmjopen-2024-088849 · Cited by 2
Sheldrick, R. C., Birudavol, J., Hirshfeld‐Becker, D. R., Carter, A. S., Perrin, E. C., Dutta, A., Benheim, T. S., Holcomb, J. M., Boudreau, A. A., Jellinek, M. S., et al. (2024) · Academic Pediatrics · doi:10.1016/j.acap.2024.102618 · Cited by 2
Rapulana, A. M., Mpotje, T., Mthiyane, N., Smit, T. K., McHugh, T. D., & Marakalala, M. J. (2025) · Frontiers in Tuberculosis · doi:10.3389/ftubr.2024.1377540 · Cited by 2
Piccardo, A., Fiz, F., Righi, S., Raffa, S., Riondato, M., Bottoni, G., Bauckneht, M., Massollo, M., Rizzo, A., Naseri, M. S. Z., et al. (2025) · European Thyroid Journal · doi:10.1530/etj-24-0320 · Cited by 2
“Two authors (FF and GT) used the QUADAS-2 method to assess the risk of bias in the studies (13).”
Antza, C., Palaska, S., Anyfanti, P., Triantis, D., Fyntrilakis, S., ZiyaSener, Y., & Kotsis, V. (2025) · Current Hypertension Reports · doi:10.1007/s11906-025-01326-7 · Cited by 2
“The QUADAS-2 tool was used to assess the risk of bias in the randomized controlled trial, while the Newcastle-Ottawa scale was used to assess the quality of the cohort and cross-sectional observational studies [14, 15].”
Chandekar, K. R., Satapathy, S., & Bal, C. S. (2025) · Clinical Nuclear Medicine · doi:10.1097/rlu.0000000000005641 · Cited by 2
Silva, R. F., Zanon, M., Ackman, J. B., Forte, G. C., Altmayer, S., Biederer, J., Bergmann, L. L., Andrade, R. G. F., & Hochhegger, B. (2025) · European Radiology · doi:10.1007/s00330-025-11366-x · Cited by 2
“Two other reviewers with 3 years of experience with meta-analyses evaluated the quality of the eligible studies using the Quality Assessment of Diagnostic Accuracy Studies (QUADAS-2) checklist, with disagreements resolved by consensus with the third, more senior reviewer [22].”
The diagnostic accuracy and feasibility of paediatric visual field tests: A systematic review
Riaz, M., Ross, N. C., & Mayer, D. L. (2025) · Ophthalmic and Physiological Optics · doi:10.1111/opo.13449 · Cited by 2
Martín‐Cardona, A., Carrasco, A., Ferrer, C., Mínguez, C. G., Luizaga, L. A., Tarroch, X., González-Puglia, G., Tristán, E., Cardozo-Rembado, N. B., Pallarés, N., et al. (2025) · International Journal of Molecular Sciences · doi:10.3390/ijms26031349 · Cited by 2
Firouzabadi, S. R., Tavanaei, R., Mohammadi, I., Alikhani, A., Ansari, A., Akhlaghpasand, M., Hajikarimloo, B., Yong, R. L. M., & Margetis, K. D. (2025) · World Neurosurgery · doi:10.1016/j.wneu.2025.123742 · Cited by 2
Derivation of a CT Angiography-Based Arch Atherosclerosis Grading in Cryptogenic Ischemic Stroke
Wadhwa, A., Singh, R., Almekhlafi, M., Menon, B. K., Nambiar, P. N., Kathuveetil, A., Kannath, S. K., Chhabra, M., Sylaja, P. N., Demchuk, A. M., et al. (2025) · Annals of Indian Academy of Neurology · doi:10.4103/aian.aian_996_24 · Cited by 2
“[14] Disagreement regarding study inclusion, data extraction, and bias assessment was resolved by discussion and consensus.”
Radiological Diagnosis of Suspected Scaphoid Fractures in Children: A Systematic Review
Chen, M. X., Lamanna, D. L., Livock, H., Smit, K. M., Carsen, S., & Cheung, K. (2025) · Plastic Surgery · doi:10.1177/22925503251322521 · Cited by 2
Jiang, Z., Guo, J., Hu, L., Zhao, X. O., Yang, S., Zhong, X., Lei, X., & Tang, Q. (2025) · BMC Oral Health · doi:10.1186/s12903-025-05809-6 · Cited by 2
“The potential for bias within these domains was evaluated and categorized as high, low, or unclear [17].”
Clinical and anatomical characteristics of basal temporal seizures: A systematic review
Bartoloméi, F., Pizzo, F., & Lagarde, S. (2025) · Epileptic Disorders · doi:10.1002/epd2.70020 · Cited by 2
Wen, Y., Huang, Y. T., Liu, Y., Zhang, S., Liu, Z., Hui, C., & Wang, Y. (2025) · Intelligence-Based Medicine · doi:10.1016/j.ibmed.2025.100244 · Cited by 4
Lin, A. H., Hsu, M., Ng, J. K. M., Farahani, S. J., Li, J. J. X., Nano, J., Raeisi‐Dehkordi, H., Tang, W., Vielh, P. R., & Muka, T. (2025) · Cytopathology · doi:10.1111/cyt.13493 · Cited by 2
Meta-analysis of the diagnostic value of SOX1 methylation in different types of cervical cancer
Hu, Y., & Cui, M. (2025) · World Journal of Surgical Oncology · doi:10.1186/s12957-025-03790-6 · Cited by 2
“Quality assessments were independently conducted by the researchers, with any discrepancies resolved through discussion [17].”
IOTA Three-Step Strategy for Classifying Adnexal Masses: A Systematic Review and Meta-Analysis
Alcázar, J. L., Vargas, F., Boscá, G., Salazar, B., Aguilar, J. C., Catalán, C., Balazs, A., Burky, D., Pertkiewicz, M., Jiménez, J. C. V., et al. (2025) · Onco · doi:10.3390/onco5020022 · Cited by 3
“Quality assessment of studies included was conducted using the QUADAS-2 tool [23].”
Abdelmahdy, N. E. E., Suliman, E. T. A. A., Mohmed, F. M. O., Elamin, N. S. A., Yousif, B. A. H., & Ahmmed, N. A. M. (2025) · Cureus · doi:10.7759/cureus.83543 · Cited by 3
“The methodological quality of included studies was evaluated using the Quality Assessment of Diagnostic Accuracy Studies-2 (QUADAS-2) tool [11], which assesses risk of bias and applicability concerns across four domains: patient selection, index test, reference standard, and flow/timing.”
Mohammed, I. A., Aliyu, B., Sharel, P. E., Nordin, S. A., & Chee, H. (2025) · Heliyon · doi:10.1016/j.heliyon.2025.e43362 · Cited by 2
Ozaki, K., Kawai, K., Ogawa, S., Kanemitsu, Y., & Ajioka, Y. (2025) · Expert Review of Anticancer Therapy · doi:10.1080/14737140.2025.2506646 · Cited by 3
Kim, Y. S., & Kim, S.-J. (2025) · Clinical Nuclear Medicine · doi:10.1097/rlu.0000000000005973 · Cited by 2
Hu, S., Lalonde-Bester, S., Salem, J., Koshy, S., Vine, D. F., Harrison, T. G., Yamamoto, J. M., & Benham, J. L. (2025) · Human Reproduction · doi:10.1093/humrep/deaf094 · Cited by 2
“…the original QUADAS as it distinguishes between bias and applicability, and identifies four key domains to assess bias, including patient selection, index test, reference standard and flow of patients through the study and timing of the index test and reference standard (Whiting et al. , 2011).”
Gebremeskele, B. T., Gebrie, H., Bogale, A., Getu, E., & Churiso, G. (2025) · BMC Infectious Diseases · doi:10.1186/s12879-025-11091-2 · Cited by 2
“Two reviewers (HG, and BT) assessed the risks of bias and applicability concerns using the quality assessment of diagnostic accuracy studies 2 (QUADAS-2) tool [38].”
Montanelli, J., Lara, A. H. H., Rivera, A. K. U., Verde, J. M., Burmester, E., Al‐Haddad, M., Hollerbach, S. H., Vilmann, P., Abu–Suboh, M., Badaoui, A., et al. (2025) · Surgical Endoscopy · doi:10.1007/s00464-025-11783-5 · Cited by 3
“The risk of bias was assessed by an adapted version of QUADAS-2 tool [20].”
Live teleultrasound for evaluation of the chest: a systematic review
Duong, V., Hannan, L. M., Tirant, K., Choe, Y. X., Hateley, E., & Muruganandan, S. (2025) · European Respiratory Review · doi:10.1183/16000617.0260-2024 · Cited by 2
“…is acknowledged that similar reviews on teleultrasound have used modified tools such as the Risk of Bias in Non-randomized Studies - of Interventions (ROBINS-I) [72] or QUADAS-2 [73]; however, the broad inclusion criteria and heterogeneity of the retrieved studies precluded the use of these tools.”
Barbosa, L., Mazetto, R. A. S. V., Defante, M. L. R., Antunes, V., Oliveira, V. M. R., Cavalcante, D., Feitoza, L. P. G. D. C., Queiroz, I., Ferreira, A. L. C., Almeida, G., et al. (2025) · Journal of Interventional Cardiac Electrophysiology · doi:10.1007/s10840-025-02075-y · Cited by 2
“We assessed the quality assessment tool of the studies using the Quality Assessment of Diagnostic Accuracy Studies (QUADAS-2) [10].”
Histochemistry Testing for Cutaneous Fungal Infections: A Meta‐Analysis
Vadali, M. V., Gener, M., & Fraga, G. R. (2025) · Journal of Cutaneous Pathology · doi:10.1111/cup.14826 · Cited by 2
“The risk of bias was evaluated using the Quality Assessment of Diagnostic Accuracy Studies (QUADAS) tool [8].”
Wang, C., Tsai, C., Li, H., Su, C., Tsai, T., Tay, J., Wu, C., Wu, M., Schmieschek, M. H. T., Onur, O. A., et al. (2025) · NeuroImage · doi:10.1016/j.neuroimage.2025.121298 · Cited by 2
“Two investigators (JT and MCW) independently assessed the risk of bias in the included studies using the QUADAS-2 (Quality Assessment of Diagnostic Accuracy Studies 2) tool (Whiting et al., 2011).”
Cao, W.-F., Leng, E.-L., Wang, J., Zhou, Y., Liu, S.-M., Wu, L.-F., Xiang, Z.-B., Rao, W., Luo, C.-Q., Hong, W.-W., et al. (2025) · Quantitative Imaging in Medicine and Surgery · doi:10.21037/qims-2024-2885 · Cited by 2
Olbrich, L., Yang, B., Poore, H., Razid, A., Sweetser, B., Damkjær, M. W., Kay, A. W., Åhsberg, J., Nathavitharana, R. R., Schiller, I., et al. (2025) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd016071.pub2 · Cited by 7
Llompart-Coll, M. M., Domínguez-Garijo, P., Manyalich-Blasi, M., Domènech-Gómez, G., Perales-Galan, I., Saavedra-Pérez, D., Rodrigo‐Calvo, M. T., Vidal‐Sicart, S., Pera-Román, M., & Vidal-Pérez, Ó. (2025) · Langenbeck s Archives of Surgery · doi:10.1007/s00423-025-03742-4 · Cited by 2
“…of cases and sample size in each group were used to compute the pooled Odds Ratios and their 95% confidence intervals (95% CI, that were estimated using the random-effects model described by Der Simonian and Laird [ 15] and the 0.5 correction in case of 0 events, with the metabin command of R.”
InfluentialMallmann, M. M., Pereira, F. L., Chammas, M. C., Duarte, M. L., Andrade, A. M., Júnior, E. L., & Ramos, O. (2025) · Radiologia Brasileira · doi:10.1590/0100-3984.2024.0108 · Cited by 2
“Studies that included a control group were assessed with the Quality Assessment of Diagnostic Accuracy Studies (QUADAS-2) tool (21) .”
Artificial Intelligence in Ultrasound-Based Diagnoses of Gynecological Tumors: A Systematic Review
Mohammed, F. S. A., Eisa, S. M. A., Madani, A. M. A., Alrowili, N. M. F., Ghaythan, A. M. K. A., Ali, I. M. M., Elamin, L., & Salad, N. A. (2025) · Cureus · doi:10.7759/cureus.85884 · Cited by 4
“The methodological quality of included studies was evaluated using the QUADAS-2 (Quality Assessment of Diagnostic Accuracy Studies) tool [11], which assesses four domains: patient selection, index test (AI model), reference standard, and flow and timing.”
Autogestão ineficaz da saúde em condições crônicas: revisão sistemática
Dantas, A. C., Araújo, J. N. D. M., Lopes, M. V. D. O., Borges, B. E. C., da Silva, C. L. B., Medeiros, H. P. D. S., da Silva, A. B., & Vítor, A. F. (2025) · Acta Paulista de Enfermagem · doi:10.37689/acta-ape/2025ar0000663 · Cited by 2
Systematic Review of Ultrasound Diagnostic Accuracy for Senile Calcified Valvular Heart Disease
Huang, Y., Wan, J., Duan, Y., Guo, X., & Huang, M. (2025) · Echocardiography · doi:10.1111/echo.70236 · Cited by 2
“The QUADAS-2 quality assessment tool [17] was independently utilized by two assessors to appraise the risk of bias in the 12 studies included.”
Cui, J., Wang, Z., Li, S., & Yu, Z. (2025) · European Journal of Gastroenterology & Hepatology · doi:10.1097/meg.0000000000003018 · Cited by 2
Roostaei, M., Saniee, N., Ahmadi, S. A. Y., Rezai, M., Tehrani‐Banihashemi, A., Baradaran, H. R., & Barzkar, F. (2025) · Academic Emergency Medicine · doi:10.1111/acem.70087 · Cited by 2
“Two independent reviewers evaluated the quality of the included studies using the Quality Assessment of Diagnostic Accuracy Studies-2 (QUADAS-2) tool [19] and any discrepancies were resolved by a third reviewer.”
Akhade, S. P., Akhade, K. S., Bhoyar, L., Ghormade, P. S., & Vaswani, V. (2025) · Journal of Forensic and Legal Medicine · doi:10.1016/j.jflm.2025.102924 · Cited by 2
Sagredo-Olivares, K., Morales, C., & Aitken-Saavedra, J. (2023) · Turkish journal of Dental Hygiene · doi:10.51847/otsbo5mojp · Cited by 2
Haritos, A. M., Long, B.-Z. S., Bani‐Fatemi, A., Howe, A. S., Li, Y., & Nowrouzi‐Kia, B. (2025) · BMJ Public Health · doi:10.1136/bmjph-2025-003011 · Cited by 2
“For diagnostic accuracy studies, the QUADAS-2 tool 28 will be employed, and for clinical prediction rule studies, the CHecklist for critical Appraisal and data extraction for systematic Reviews of prediction Modelling Studies (CHARMS) checklist 29 will be considered (online supplemental appendix…”
Taychaburapanone, P., Pongchaikaikiti, P., Onraksa, W., Chindasombatcharoen, S., & Suntipap, M. (2025) · The Journal of Maternal-Fetal & Neonatal Medicine · doi:10.1080/14767058.2025.2537231 · Cited by 2
“The quality of the included studies was independently assessed by two reviewers (S.C., and W.O.) using the Quality Assessment of Diagnostic Accuracy Studies-2 (QUADAS-2) [24] tool for diagnostic studies or the Newcastle-Ottawa Scale (NOS) [25] for studies evaluating association.”
Fanshawe, J. B., Lawrence, R., Ghanem, D. A., Pauli, L., Whincup, R., Salter, E., Sargent, B., Evans, L. J., Jasani, I., Oliver, D., et al. (2025) · Schizophrenia Research · doi:10.1016/j.schres.2025.07.020 · Cited by 2
“Two trained reviewers (B.S., D.A.G., E.S., L.P., and R.L.) assessed each paper using the QUADAS-2 tool for systematic reviews of diagnostic accuracy studies to assess risk of bias and applicability (Whiting et al., 2011; Page et al., 2017).”
Xu, X., & Wang, J. (2025) · Archives of Rheumatology · doi:10.5152/archrheumatol.2025.11128 · Cited by 2
Circulating microRNA-1 as a diagnostic biomarker for acute myocardial infarction: a meta-analysis
Li, G., Zhao, J., Zhou, Z., Xu, W., Wang, S., & Sun, Q. (2025) · Cardiology Journal · doi:10.5603/cj.100348 · Cited by 2
Singh, S., Huang, H., Andrade, S. E., Butler, L., Kim, S. H., Noan‐Lainé, M. L., Pinheiro, S. P., Shaughnessy, L., Desrochers, O., & Rodriguez‐Watson, C. (2025) · Clinical Pharmacology & Therapeutics · doi:10.1002/cpt.70036 · Cited by 2
van Boxel, M. F., Kaplan, A., Ring, D., Jaarsma, E. H., Doornberg, J. N., & Obdeijn, M. C. (2025) · Journal of Hand Surgery (European Volume) · doi:10.1177/17531934251367541 · Cited by 2
“…independently assessed by two reviewers using the Quality Assessment of Diagnostic Accuracy Studies-2 (QUADAS-2) for diagnostic accuracy studies (Whiting et al., 2011); the Mixed Methods Appraisal Tool (MMAT) for quantitative studies, case reports and mixed method studies (Hong et al., 2018;…”
Novel and optimized diagnostics for pediatric TB in endemic countries: NOD-pedFEND study protocol
Song, R., Bijker, E. M., Kisitu, G. P., Douglass, E., Nasinghe, E., Basile, F. W., Khambati, N., Penn‐Nicholson, A., Rühwald, M., Kim, S., et al. (2025) · BMC Pediatrics · doi:10.1186/s12887-025-05554-3 · Cited by 2
“The study will be conducted and reported following Standards for Reporting of Diagnostic Accuracy Studies (STARD) guidelines for reporting diagnostic accuracy studies [15, 16].”
Kim, B. J., Kang, S. J., Nam, S. Y., Bang, C. S., Min, B., Kim, S. E., Kim, S. Y., Lim, H. C., Tae, C. H., Lee, M. W., et al. (2025) · The Korean Journal of Helicobacter and Upper Gastrointestinal Research · doi:10.7704/kjhugr.2025.0020 · Cited by 4
Shi, J., Lin, J., Liu, W., Li, W., Zhu, H., Yin, N., Zheng, H., Gao, Y., & Xu, M. (2025) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.70120 · Cited by 2
“Bias risk in the included studies was evaluated using QUADAS-2 in Review Manager 5.3 (RevMan) [20].”
InfluentialLangkilde, H. Z., Davidsen, J. R., Harders, S. W., Patabendige, S., Nilsson, A. C., Svenungsson, E., Touma, Z., Fløjborg, S., Christensen, R., & Voss, A. (2025) · Seminars in Arthritis and Rheumatism · doi:10.1016/j.semarthrit.2025.152861 · Cited by 2
Clinical Utility of Magnetoencephalography in Epilepsy Evaluation: A Qualitative Systematic Review
Kim, H.-S., Lee, J., Jeong, C.-H., & Koo, Y. S. (2025) · Journal of Epilepsy Research · doi:10.14581/jer.25010 · Cited by 2
Mohammed, M., Fernandez‐Medina, T., Rajashekhar, M., Baker, S., & Jennings, E. A. (2025) · International Journal of Biomedical Imaging · doi:10.1155/ijbi/9065572 · Cited by 3
Smith, F., Holland, A., Penny, K. I., Elen, M., & McGirr, D. (2014) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd011196 · Cited by 2
Allofs, J., van Baal, K., Schwarz, F., Ehrenbrusthoff, K., & Hering, T. (2018) · physioscience · doi:10.1055/s-0044-100533 · Cited by 2
“[40] Whiting PF, Rutjes AW, Westwood ME et al.”
Lectura crítica de revisiones sistemáticas y metanálisis en el diagnóstico por imagen
Plana, N., Zamora, J., & Abraira, V. (2015) · Radiología · doi:10.1016/j.rx.2015.04.003 · Cited by 2
Finding the Evidence for Decision Analytic Cost Effectiveness Models
Edlin, R. P., McCabe, C. J., Hulme, C. T., Hall, P. S., & Wright, J. M. (2015) · Springer eBooks · doi:10.1007/978-3-319-15744-3_2 · Cited by 2
Sun, Y., Li, X.-T., Tang, L., Zhang, X.-Y., Zhang, X., Cui, Y., Li, J., Gu, J. F., & Shen, L. (2012) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd009867 · Cited by 2
RetractedForns index and 'FIB4' for staging of fibrosis in adults with chronic hepatitis C
Kalafateli, M., Gurusamy, K. S., Noel-Storr, A. H., Burroughs, A. K., & Tsochatzis, E. A. (2015) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd011929 · Cited by 2
Sudarsanam, T. D., & Tharyan, P. (2013) · Clinical Epidemiology and Global Health · doi:10.1016/j.cegh.2013.07.005 · Cited by 2
Reliability and Accuracy of Infrared Temperature: A Systematic Review
Park, S.-H. (2014) · Korean Journal of Adult Nursing · doi:10.7475/kjan.2014.26.6.668 · Cited by 2
Vincent, K. (2013) · International Musculoskeletal Medicine · doi:10.1179/1753614613z.00000000058 · Cited by 2
Tests for screening for hearing loss in children about to start school
Zhelev, Z., Hyde, C., Fitzgerald, J., Ukoumunne, O. C., Briscoe, S., Chisnell, J., & Grigore, B. (2015) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd011951 · Cited by 2
Predictive value of microRNAs as novel biomarkers in detection of lymphoma.
Wang, Y., Sun, D., Wang, J., Dou, A., & Zheng, C. (2015) · Europe PMC (PubMed Central) · Cited by 3
Gao, W., Shi, Y., Liu, W., Lin, W.-Y., Wu, J. C.-C., Chan, J. Y. W., & Wong, T. (2015) · Frontiers in Oncology · doi:10.3389/fonc.2015.00296 · Cited by 2
Critical appraisal in the practice of laboratory medicine
Price, C. P., & Christenson, R. H. (2015) · Annals of Clinical Biochemistry International Journal of Laboratory Medicine · doi:10.1177/0004563215599008 · Cited by 2
Comment utiliser la grille STARD et l'outil QUADAS-2?
Cohen, J. F., Bossuyt, P. M., Lévy, C., Chalumeau, M., Martinot, A., & Launay, E. (2015) · Archives de Pédiatrie · doi:10.1016/s0929-693x(15)30095-6 · Cited by 2
Self-citationCritical Appraisal of Subgroup Analysis
Roever, L. (2016) · Evidence based Medicine and Practice · doi:10.4172/2471-9919.1000e115 · Cited by 2
Wegner, I., Hooft, L., Reitsma, J. B., Pameijer, F. A., Hoekstra, O. S., de Bree, R., & Stegeman, I. (2016) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd012321 · Cited by 2
Self-citationWissenschaft praktisch – evidenzbasierte Praxis
Ritschl, V., Stamm, T., & Unterhumer, G. (2016) · Studium Pflege, Therapie, Gesundheit · doi:10.1007/978-3-662-49908-5_14 · Cited by 2
Wegner, I., Hooft, L., Reitsma, J. B., Pameijer, F. A., de Bree, R., & Stegeman, I. (2016) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd012115 · Cited by 2
Self-citationLund, M., Bjerre, T. A., Grønbæk, H., Mortensen, F. V., & Andersen, P. K. (2016) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd012388 · Cited by 2
A Systematic Review of Child Abuse Screening Instruments
Kim, H.-K., Choi, H.-M., & Park, H.-J. (2016) · Child Health Nursing Research · doi:10.4094/chnr.2016.22.4.265 · Cited by 2
Systematische Fehler in klinischen Studien: Eine Übersicht
Golder, W. A. (2017) · Zeitschrift für Rheumatologie · doi:10.1007/s00393-016-0253-5 · Cited by 3
Are these results trustworthy? A guide for reading the medical literature.
Alahdab, F., Morrow, A. S., Alsawas, M., & Murad, M. H. (2017) · PubMed Central · doi:10.4103/2231-0770.203611 · Cited by 3
“For example, the Cochrane risk of bias for randomized trials,[3] the ROBINS tool for nonrandomized interventional studies[4] or the Newcastle–Ottawa tool for cohort and case–control studies,[5] and the QUADAS‐2 for diagnostic studies.[6] For a clinician, applying these tools may be challenging as they require time and…”
Lee, H.-S., & Park, S.-W. (2017) · Journal of the Korean Society of Physical Medicine · doi:10.13066/kspm.2017.12.3.49 · Cited by 2
Tests to assist in the staging of cutaneous squamous cell carcinoma: a generic protocol
Dinnes, J., Matin, R., Webster, A. C., Lawton, P. A., Chuchu, N., Bayliss, S. E., Takwoingi, Y., Davenport, C. F., Godfrey, K., O'Sullivan, C., et al. (2017) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd012773 · Cited by 2
Self-citationHughes, J. M., Penney, C., Boyd, S., & Daley, P. (2018) · Epidemiology and Infection · doi:10.1017/s0950268818000596 · Cited by 2
A systematic review on the use of the Breast Lesion Excision System in breast disease
Sanderink, W. B. G., Laarhuis, B. I., Strobbe, L. J. A., Bult, P., Karssemeijer, N., & Mann, R. M. (2018) · European Journal of Cancer · doi:10.1016/s0959-8049(18)30687-7 · Cited by 2
Role of urinary viral haufen in diagnosis of polyomavirus nephropathy: A systematic review
Khairwa, A., & Jat, K. (2018) · Indian Journal of Transplantation · doi:10.4103/ijot.ijot_68_17 · Cited by 2
Metadata
- Authors
- Whiting, P. F., Rutjes, A. W. S., Westwood, M. E., Mallett, S., Deeks, J. J., Reitsma, J. B., Leeflang, M. M. G., Sterne, J. A. C., Bossuyt, P. M. M., & the QUADAS-2 Group*
- Affiliations
- University of Bern (CH)
- Corresponding author
- Whiting, Penny F.
- ORCID
- Venue
- Annals of Internal Medicine
- Publisher
- American College of Physicians
- Published
- 2011-10-18
- Volume
- 155
- Issue
- 8
- Pages
- 529-536
- ISSN
- 0003-4819 (ISSN-L)
- 1539-3704
- OpenAlex
- W2107638293
- Semantic Scholar
- 8a5d0b5a9271ea14bcb8479bc32d3844a80655b9
- Cited by
- 14,199
- References
- 18
- Citations by year
- 2026: 1484 · 2025: 1569 · 2024: 1524 · 2023: 1305 · 2022: 1420 · 2021: 1514 · 2020: 1245 · 2019: 955 · 2018: 767 · 2017: 637 · 2016: 580 · 2015: 528 · 2014: 363 · 2013: 217 · 2012: 75
- FWCI
- 224.36
- Type
- journal article
- Language
- en
- Open access
- green
- hdl.handle.net
- Licence
- cc-by
- www.acpjournals.org/journal/aim/text-and-data-mining (tdm)
- Locations
- Annals of Internal Medicine (publishedVersion)
- PubMed (publishedVersion)
- Pure Amsterdam UMC (publishedVersion)
- Data Archiving and Networked Services (DANS) (submittedVersion)
- Florence Research (University of Florence) (submittedVersion)
- IRIS UNIMORE (University of Modena and Reggio Emilia) (submittedVersion, cc-by)
- University of Birmingham Research Portal (University of Birmingham) (submittedVersion)
- Bristol Research (University of Bristol) (submittedVersion)
- Funders
- Cancer Research UK
- Topics
- Social Sciences › Decision Sciences › Statistics, Probability and Uncertainty › Meta-analysis and systematic reviews
- Physical Sciences › Mathematics › Statistics and Probability › Statistical Methods in Epidemiology
- Health Sciences › Medicine › Public Health, Environmental and Occupational Health › Clinical practice guidelines implementation
- Keywords
- QUADAS-2, diagnostic accuracy studies, quality assessment, risk of bias, applicability, patient selection, index tests, reference materials, flowcharts, systematic reviews
- MeSH terms
- Diagnosis, Humans, Quality Control, Surveys and Questionnaires, Reference Standards, Review Literature as Topic, Time Factors, Bias, Patient Selection, Evidence-Based Medicine
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
A language model drew the claims from the paper on 2026-11-23, under version 3 of the claim definition (model deepseek-v4.1-flash, prompt extract-v3).
A second model labelled each claim on 2026-11-23 (model jev-1.13-20260917, definition revision gold-guideline-v0.2).
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.