QUADAS-2: A Revised Tool for the Quality Assessment of Diagnostic Accuracy Studies
Open accessThe DOI matches its Crossref record; 18 of the 18 references it cites were found in a registry or an index; none of the 21 sources its claims cite is checked for support yet.
Abstract
In 2003, the QUADAS tool for systematic reviews of diagnostic accuracy studies was developed. Experience, anecdotal reports, and feedback suggested areas for improvement; therefore, QUADAS-2 was developed. This tool comprises 4 domains: patient selection, index test, reference standard, and flow and timing. Each domain is assessed in terms of risk of bias, and the first 3 domains are also assessed in terms of concerns regarding applicability. Signalling questions are included to help judge risk of bias. The QUADAS-2 tool is applied in 4 phases: summarize the review question, tailor the tool and produce review-specific guidance, construct a flow diagram for the primary study, and judge bias and applicability. This tool will allow for more transparent rating of bias and applicability of primary diagnostic accuracy studies.
Overview
CoChat Summary
TL;DR
QUADAS-2 is a revised tool for assessing risk of bias and applicability in diagnostic accuracy studies, developed through a 4-stage evidence-based consensus process. It replaces the original QUADAS “yes/no/unclear” quality rating with domain-level judgments of low, high, or unclear risk of bias and concerns about applicability.
Key findings
- QUADAS-2 separates “quality” into risk of bias and concerns regarding applicability, defining quality as the degree to which diagnostic accuracy estimates avoided bias and the extent to which primary studies are applicable to the review question.
- The tool has 4 key domains—patient selection, index test, reference standard, and flow and timing—with the first 3 also assessed for applicability; it is completed in 4 phases and uses signaling questions to help judge risk of bias.
- Development drew on 4 reviews: 54 diagnostic accuracy reviews published between 2007 and 2009, structured feedback from 64 systematic reviewers who had used QUADAS, 101 studies on sources of bias and variation, and 8 studies evaluating QUADAS; a 1-day consensus meeting had 24 attendees, and piloting occurred in 5 reviews.
- Interrater reliability varied considerably, with better agreement on applicability than on risk of bias; all participants preferred QUADAS-2 to the original tool, but the authors could not currently include criteria for studies comparing multiple index tests because the evidence base was insufficient.
Methods
- Tool development followed Moher and colleagues’ 4-stage approach: define the scope, review the evidence base, hold a face-to-face consensus meeting, and refine through piloting.
- A steering group of 9 experts set the scope; the consensus meeting was held on 21 September 2010 in Birmingham, United Kingdom, with 24 attendees who split into groups of 4 to 6 participants; multiple rounds of piloting used online questionnaires and other feedback, including pairs of reviewers piloting QUADAS-2 in 5 reviews.
- No primary statistical analysis was reported; the work synthesized evidence reviews, consensus decisions, and pilot feedback to produce and refine the tool.
Limitations
- Stated: the authors decided they cannot currently include criteria for assessing studies that compare multiple index tests within QUADAS-2 because of the limited evidence base on risk of bias and sources of variation in such studies, and they plan future work on this topic.
- Stated: piloting showed poor interrater reliability and problems applying the domain on comparative accuracy studies; interrater reliability varied considerably overall, with better agreement on applicability than on risk of bias.
- Evident from the text: full details of the 4 evidence reviews were to be published separately, and the main text reports no quantitative reliability estimates, referring instead to an Appendix Table.
Model-written summary. Check it against the paper before relying on it.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
0 Valid · 0 Not valid · 16 Not checked · 24 Own results and interpretations
In the paper
“In a review on anti-cyclic citrullinated peptide antibodies for diagnosing rheumatoid arthritis (10), we found that some studies enrolled consecutive participants with confirmed diagnoses. In these studies, testing for anticyclic citrullinated peptide antibody showed greater sensitivity than in studies that included patients with suspected disease but an unconfirmed diagnosis (that is, difficult-t”
§ QUADAS-2: A Revised Tool for the Quality Assessment of Diagnostic Accuracy Studies > Signaling question 2: Was a case-control design avoided? Signaling question 3: Did the study avoid inappropriate exclusions?
What the sources say
- Not matchedcites [10]
The reference list we hold has no entry [10].
plainstates an association- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Not matched
A statement the paper makes itself — it cites no source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“Studies that make inappropriate exclusions (for example, not including”
§ QUADAS-2: A Revised Tool for the Quality Assessment of Diagnostic Accuracy Studies > Signaling question 2: Was a case-control design avoided? Signaling question 3: Did the study avoid inappropriate exclusions?
hedgedstates a possible cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
None of the sources cited for this claim could be matched to a paper, so there is nothing to check it against.
In the paper
“Because the accuracy of a test may depend on where it will be used in the diagnostic pathway, review authors are asked to describe patients in terms of setting, intended use of the index test, patient presentation, and previous testing (8,9).”
§ QUADAS-2: A Revised Tool for the Quality Assessment of Diagnostic Accuracy Studies > Phase 1: Review Question
What the sources say
- Not matchedcites [8]
The reference list we hold has no entry [8].
- Not matchedcites [9]
The reference list we hold has no entry [9].
hedgedstates a possible cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Not matched
In the paper
“Development of QUADAS-2 was based on the 4-stage approach proposed by Moher and colleagues (4): define the scope, review the evidence base, hold a face-to-face consensus meeting, and refine the tool through piloting.”
§ QUADAS-2: A Revised Tool for the Quality Assessment of Diagnostic Accuracy Studies > METHODS
What the sources say
- Not matchedcites [4]
The reference list we hold has no entry [4].
plainstates a cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: unclear — It is unclear whether the paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Not matched
None of the sources cited for this claim could be matched to a paper, so there is nothing to check it against.
In the paper
“Studies enrolling participants with known disease and a control group without the condition may similarly exaggerate diagnostic accuracy (7,11).”
§ QUADAS-2: A Revised Tool for the Quality Assessment of Diagnostic Accuracy Studies > Signaling question 2: Was a case-control design avoided? Signaling question 3: Did the study avoid inappropriate exclusions?
What the sources say
- Not matchedcites [7]
The reference list we hold has no entry [7].
- Not matchedcites [11]
The reference list we hold has no entry [11].
hedgedstates a possible cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Not matched
10 more claims
Create a free account to see all 40 claims and every source verdict.
- Probably not a substantial claim. 19
- It may state two separate claims as one. 16
- The quote only partly states this claim. 2
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“We assessed the study-level risk of bias with the QUADAS-2 tool”
In the citing paper
“We developed a revised risk-of-bias assessment tool to address these issues, incorporate advances in assessment of risk of bias used in other recently developed tools, 9 10 and integrate recent developments in estimation of intervention effects from randomised trials. 11”
From RoB 2: a revised tool for assessing risk of bias in randomised trials (2019) · cites this paper as [10]
In the citing paper
“Two reviewers independently assessed the quality of the included studies with the Quality Assessment of Diagnostic Accuracy Studies (Quadas-2) [33].”
From High-standard predictive equations for estimating body composition using bioelectrical impedance analysis: a systematic review (2024) · cites this paper as [33]
In the citing paper
“The quality of the selected studies was rigorously assessed using the Checklist for Artificial Intelligence in Medical Imaging (CLAIM) alongside the Quality Assessment of Diagnostic Accuracy Studies-2 (QUADAS-2).23,24”
From Artificial Intelligence Detection and Segmentation Models: A Systematic Review and Meta-Analysis of Brain Tumors in Magnetic Resonance Imaging (2024) · cites this paper as [24]
In the citing paper
“The methodological quality of each selected study was assessed according to the Quality Assessment of Diagnostic Accuracy Studies (QUADAS-2) checklist [15]”
From The diagnostic accuracy of digital, infrared and mercury-in-glass thermometers in measuring body temperature: a systematic review and network meta-analysis (2021) · cites this paper as [15]
20 more claims about this paper
Create a free account to see every claim other papers make about this one.
Citations
Cites
The Cochrane Collaboration's tool for assessing risk of bias in randomised trials
Higgins, J. P. T., Altman, D. G., Gotzsche, P. C., Juni, P., Moher, D., Oxman, A. D., Savovic, J., Schulz, K. F., Weeks, L., Sterne, J. A. C., et al. (2011) · BMJ · doi:10.1136/bmj.d5928 · Cited by 33,817
Self-citationWhiting, P., Rutjes, A. W., Reitsma, J. B., Bossuyt, P. M., & Kleijnen, J. (2003) · BMC Medical Research Methodology · doi:10.1186/1471-2288-3-25 · Cited by 3,592
Self-citationThe Hazards of Scoring the Quality of Clinical Trials for Meta-analysis
Jüni, P. (1999) · JAMA · doi:10.1001/jama.282.11.1054 · Cited by 1,981
Empirical evidence of design-related bias in studies of diagnostic tests.
Lijmer, J. G. (1999) · JAMA · doi:10.1001/jama.282.11.1061 · Cited by 1,861 · cited 2×
“Studies enrolling participants with known disease and a control group without the condition may similarly exaggerate diagnostic accuracy (7, 11).”
BackgroundGuidance for Developers of Health Research Reporting Guidelines
Moher, D., Schulz, K. F., Simera, I., & Altman, D. G. (2010) · PLoS Medicine · doi:10.1371/journal.pmed.1000217 · Cited by 1,437
Systematic Reviews of Diagnostic Test Accuracy
Leeflang, M. M. G., Deeks, J. J., Gatsonis, C., & Bossuyt, P. M. M. (2008) · Annals of Internal Medicine · doi:10.7326/0003-4819-149-12-200812160-00008 · Cited by 1,124
Self-citationSources of Variation and Bias in Studies of Diagnostic Accuracy: A Systematic Review
Whiting, P., Rutjes, A. W. S., Reitsma, J. B., Glas, A. S., Bossuyt, P. M. M., & Kleijnen, J. (2004) · Annals of Internal Medicine · doi:10.7326/0003-4819-140-3-200402030-00010 · Cited by 798 · cited 4×
“The third review was an update on sources of bias and variation in diagnostic accuracy studies that included 101 studies (7).”
BackgroundInfluentialSelf-citationEvaluation of QUADAS, a tool for the quality assessment of diagnostic accuracy studies
Whiting, P. F., Weswood, M. E., Rutjes, A. W., Reitsma, J. B., Bossuyt, P. N., & Kleijnen, J. (2006) · BMC Medical Research Methodology · doi:10.1186/1471-2288-6-9 · Cited by 769
Self-citationLeeflang, M. M. G., Moons, K. G. M., Reitsma, J. B., & Zwinderman, A. H. (2008) · Clinical Chemistry · doi:10.1373/clinchem.2007.096032 · Cited by 346 · cited 1×
“Test performance is likely to be poorer in an independent sample of patients in whom the same threshold is used (12).”
BackgroundSelf-citationNo role for quality scores in systematic reviews of diagnostic accuracy studies
Whiting, P., Harbord, R., & Kleijnen, J. (2005) · BMC Medical Research Methodology · doi:10.1186/1471-2288-5-19 · Cited by 337
Self-citation
Cited by
Items 11,001–11,100 of 14,770
Tshivhula, N., Mbunge, E., & Makaba, T. (2026) · BMC Medical Informatics and Decision Making · doi:10.1186/s12911-026-03624-9 · Cited by 2
“The methodological quality and risk of bias of the included diagnostic and classification studies were assessed using adapted criteria from the Quality Assessment of Diagnostic Accuracy Studies 2 (QUADAS-2) tool [16].”
InfluentialPei, L. X., Farrell, C. C., Mlewa, S. C., Sauer, C., Sejane, K., Kirby, N. V., McKendry, J., Charles, C., Fischer, J. A. J., Green, T., et al. (2026) · Advances in Nutrition · doi:10.1016/j.advnut.2026.100681 · Cited by 2
“Explanations for each GRADE assessment are as follows: 1 Not serious: most information was from studies at low risk of bias for each of the 4 domains in the QUADAS-2 tool [17].”
Cui, L., Wang, M., Xu, Y., Wei, W., & Zhao, X. (2026) · BMC Emergency Medicine · doi:10.1186/s12873-026-01639-z · Cited by 3
“The methodological quality of the included studies was evaluated using the Quality Assessment of Diagnostic Accuracy Studies-2 (QUADAS-2) tool [23], which assesses both risk of bias and applicability concerns.”
Lischker, S., Pestel, G., Schmidtmann, I., & Griemert, E. (2026) · Anaesthesia · doi:10.1111/anae.70250 · Cited by 2
“At least two authors (EG, SL and/or IS) independently assessed the risk of bias throughout the process using the revised Quality Assessment of Diagnostic Accuracy Studies (QUADAS-2) tool [39, 40].”
Dhollander, N., Jaafar, I., Almonte, M., Rezhake, R., Downham, L., Valls, J., Ramírez, A. T., Baena, A., Gaffikin, L., Blumenthal, P. D., et al. (2026) · EClinicalMedicine · doi:10.1016/j.eclinm.2026.104009 · Cited by 2
Guimarães, H. H. D. S. D., & Matos, K. (2026) · Dentistry Review · doi:10.1016/j.dentre.2026.100432 · Cited by 2
Qi, S., Jiang, Y., Li, H., Gong, X., Li, Q., Zhou, X., & li, S. (2026) · BMC Pulmonary Medicine · doi:10.1186/s12890-026-04417-6 · Cited by 2
“This review focused on diagnostic accuracy, so the Quality Assessment of Diagnostic Accuracy Stud-ies-2 (QUADAS-2) was used as the primary assessment tool [22].”
Radócz, L., Nagy, A., Szöllősi, N., Kiss, N. É., Szabó, A., Tamás, J., Siphiwe, N. G., & Radócz, L. (2026) · Remote Sensing · doi:10.3390/rs18132063 · Cited by 3
Mohammed, S. I., Abdulameer, K. A., salih, M., & Al-Hussaniy, H. A. (2026) · Journal of Umm Al-Qura University for Medical Sciences · doi:10.1007/s44361-026-00045-1 · Cited by 2
Artificial Intelligence in the Detection of Papilledema: A Systematic Review
Samoilă, O., Antonoupoulou, V., & Samoilă, L. (2026) · Journal of Clinical Medicine · doi:10.3390/jcm15134878 · Cited by 2
Moriguchi, C. T., Chaves, J. S., Ruffini, M. D. L., Alves, L. D. L., Negreiros, I. P., de Souza, A. M., Cordeiro, L. H. G., SILVEIRA, M. M., Moura, D., Reis, F., et al. (2026) · Geriatrics and gerontology international/Geriatrics & gerontology international · doi:10.1111/ggi.70549 · Cited by 2
Guimarães, H. H. D. S. D., & Matos, K. (2026) · European Journal Of Oral Sciences · doi:10.1111/eos.70116 · Cited by 2
Accuracy of administrative data in ascertaining health conditions: a systematic review
Campbell, A. C., Tyler, J., Shuttleworth, R. R., Pearce, L. A., Heerde, J. A., Borschmann, R., Sawyer, S. M., Preen, D. B., Kinner, S. A., & Calais‐Ferreira, L. (2026) · JAMIA Open · doi:10.1093/jamiaopen/ooag109 · Cited by 2
“28 Through QUADAS-2, we assessed the risk of bias in four domains: (1) patient selection, which assessed whether included participants and setting did not introduce bias to the study, (2) index test (ie, the diagnostic code(s) in administrative data being validated), assessing if the index test was…”
Leseman, C. A., Bonomi, A. M., Schuitema, J., Granieri, S., Chen, M., Maker, A. V., Ateeb, Z., Wood, L. D., Voermans, R. P., Marchegiani, G., et al. (2026) · JAMA Network Open · doi:10.1001/jamanetworkopen.2026.17587 · Cited by 3
Ardila, C. M., Vivares‐Builes, A. M., & Pineda‐Vélez, E. (2026) · Healthcare · doi:10.3390/healthcare14131952 · Cited by 2
Chanteau, A., Faity, G. V., Mahé, G., Sabia, S., & Faucheur, A. L. (2026) · Sports Medicine - Open · doi:10.1186/s40798-026-01039-4 · Cited by 2
“The risk of bias in suitable validation studies was assessed via a modified version of the Quality Assessment of Diagnostic Accuracy Studies (QUADAS-2) tool [15].”
Freire, M. L., de Assis, T. S. M., de Avelar, D. M., Rabello, A., Cota, G., & Silva, S. N. (2026) · Diagnostic Microbiology and Infectious Disease · doi:10.1016/j.diagmicrobio.2026.117537 · Cited by 2
Bello, A. D., goujon, A., Kassab, D., Prudhomme, T., Frontczak, A., & Culty, T. (2026) · Transplant International · doi:10.3389/ti.2026.16661 · Cited by 2
Albano, D., Bertagna, F., Piccardo, A., Fiz, F., & Treglia, G. (2026) · Pediatric Radiology · doi:10.1007/s00247-026-06713-z · Cited by 2
Yan, X., Lei, S., Hu, L., Qin, M., & Wu, N. (2026) · Frontiers in Endocrinology · doi:10.3389/fendo.2026.1853785 · Cited by 2
Rogers, G., Derezea, E., Sadler, L., Wang, H., Cramp, M., Ryder, S. D., Watt, K., Whiting, P. F., Rogers, M., Bell, J., et al. (2026) · BMJ Open Gastroenterology · doi:10.1136/bmjgast-2025-002155 · Cited by 3
“We used QUADAS-2, 20 and QUADAS-C for comparative accuracy studies, 21 to assess the risk of bias of included studies across four domains: patient selection, index test, reference standard and flow and timing.”
Self-citationChen, H., & Chen, C. (2026) · Micromachines · doi:10.3390/mi17070863 · Cited by 2
Babel, S., Baral, S., Peeran, S. R. H., & Jonathan, G. E. (2026) · Clinical & Experimental Metastasis · doi:10.1007/s10585-026-10420-2 · Cited by 2
Bove, A. M., Carroll, L. A., Cone, S., Dibblee, P., Hensley, C. P., Lenington, K., Manner, P. A., Scalzitti, D. A., Tompkins, J., & Bade, M. (2026) · Physical Therapy · doi:10.1093/ptj/pzag058 · Cited by 5
Sasikumar, R., Aditya, A., Kulkarni, N., Fargade, A., & Diwan, V. (2026) · Asian Pacific Journal of Cancer Prevention · doi:10.31557/apjcp.2026.27.7.2447 · Cited by 2
Artificial intelligence for dental caries detection: An umbrella review
Bittar, A., Cavalli, V., & Özcan, M. (2026) · Journal of Dentistry · doi:10.1016/j.jdent.2026.106944 · Cited by 2
Hatch, R., Harley, J. D., Douglass, B. W., Carreira, D. S., Christoforetti, J. J., Jimenez, A. E., Martin, R. L., Matsuda, D. K., Wolff, A. B., & Hassan, M. M. (2026) · Arthroscopy The Journal of Arthroscopic and Related Surgery · doi:10.1002/arj.70395 · Cited by 3
Noninvasive prenatal cell-free fetal DNA-based screening for aneuploidies other than trisomy 21.
(2014) · PubMed · Cited by 2
Meta-analysis of diagnostic test accuracy in neurosurgical practice
Dubourg, J., Berhouma, M., Cotton, M., & Messerer, M. (2012) · Neurosurgical FOCUS · doi:10.3171/2012.5.focus1295 · Cited by 4
Potential for Meta-Analysis in the Realm of Preharvest Food Safety
Sargeant, J. M., & O'Connor, A. M. C. (2016) · Microbiology Spectrum · doi:10.1128/microbiolspec.pfs-0004-2014 · Cited by 2
Zhang, J., Wang, J., Han, L., Cao, X., & Shields, L. E. (2016) · Nursing Outlook · doi:10.1016/j.outlook.2016.11.004 · Cited by 2
Systematische Fehler in klinischen Studien: Eine Übersicht
Golder, W. A. (2017) · Der Ophthalmologe · doi:10.1007/s00347-017-0471-5 · Cited by 4
Mehrjardi, M. Z., & Keshavarz, E. (2017) · Journal of diagnostic medical sonography · doi:10.1177/8756479317702619 · Cited by 2
Ellerbrock, J., Bohnen, J. M. H. A., van Balen, V. A. L., Mulder, E., Aardenburg, R., & Spaanderman, M. E. A. (2017) · Gynecological Endocrinology · doi:10.1080/09513590.2017.1369516 · Cited by 2
Ultrasound in the Limited-Resource Setting: A Systematic Qualitative Review
Hallweaver, M., McBeth, C., Stolz, L. A., Studer, A., & Schick, M. (2019) · Current Radiology Reports · doi:10.1007/s40134-019-0331-y · Cited by 2
Abdelnaeem, A. O., Vining, R. D., & Youssef, A. R. (2019) · Physical Therapy Reviews · doi:10.1080/10833196.2019.1637600 · Cited by 2
The Accuracy of SPECT/CT for Diagnosing Lumbar Zygapophyseal Joint Pain: a Systematic Review
Conger, A., Burnham, T. R., Speckman, R. A., Randall, D. J., Reisinger, R., Tate, Q., Spiker, R., Schneider, B. J., Cushman, D. M., & McCormick, Z. L. (2019) · Current Physical Medicine and Rehabilitation Reports · doi:10.1007/s40141-019-00237-4 · Cited by 2
Babafemi, E. O., Cherian, B. P., Ouma, B., & Mogoko, G. M. (2019) · Systematic Reviews · doi:10.1186/s13643-019-1137-y · Cited by 2
Martins, J. P., Felgueiras, M. M., & Santos, R. (2020) · Journal of Microbiological Methods · doi:10.1016/j.mimet.2020.105912 · Cited by 2
Delirium screening tools: A protocol for a systematic review and meta-analysis
Liu, Y., Zhang, Q., Zhao, Y., Gao, Z.-Y., Wei, Z., Guo, Z., Chen, M., Zhang, Q., & Yang, X. (2020) · Medicine · doi:10.1097/md.0000000000021595 · Cited by 2
“Applying the standards adapted from the Quality Assessment of Diagnostic Accuracy Studies 2 (QUADAS-2),([27]) the bias risk for each study will be graded by two reviewers(YJL and QZ) as low, moderate or high independently.”
Dubé, E., Crozier, M., Middleton, A., Best, B. A. B., & Ohle, R. (2021) · Canadian Journal of Emergency Medicine · doi:10.1007/s43678-020-00012-8 · Cited by 2
Podstawka, Z., Zieliński, G., & Gawda, P. (2020) · Journal of Education Health and Sport · doi:10.12775/jehs.2020.10.08.006 · Cited by 2
Hu, J., Zhang, C., Wang, S., Chen, X., Hu, J., & Liu, X. (2021) · Diagnostic Microbiology and Infectious Disease · doi:10.1016/j.diagmicrobio.2021.115351 · Cited by 2
Capp, E., & Nienov, O. H. (2020) · Lume (Universidade Federal do Rio Grande do Sul) · Cited by 2
Kim, K., & Kim, S. (2021) · Pancreas · doi:10.1097/mpa.0000000000001760 · Cited by 2
Wen, J., Bai, X., Niu, Y., & Hu, Z. (2021) · International Journal of Clinical Practice · doi:10.1111/ijcp.14538 · Cited by 2
Jiang, C., Yu, W., & Hua, Z. (2021) · Clinical and investigative medicine · doi:10.25011/cim.v44i2.36356 · Cited by 2
Diagnostic Value of Urinary MicroRNAs for Bladder Cancer in Asia
Cui, Y., & Zhou, T. G. (2021) · Journal of College of Physicians And Surgeons Pakistan · doi:10.29271/jcpsp.2021.10.1207 · Cited by 2
Fowler, G., Macefield, R. C., Hardacre, C., Callaway, M. P., Smart, N. J., & Blencowe, N. (2021) · BMJ Open · doi:10.1136/bmjopen-2021-054411 · Cited by 3
El-Nakeep, S. A. K., & El-Nakeep, M. (2021) · Artificial Intelligence in Gastroenterology · doi:10.35712/aig.v2.i5.124 · Cited by 2
Ruan, D., & Sun, L. (2021) · Clinical and Translational Imaging · doi:10.1007/s40336-021-00471-8 · Cited by 2
Jiyad, Z., Plasmeijer, E. I., Keegan, S., Samarasinghe, V., Green, A. C., & Akhras, V. (2022) · Dermatology · doi:10.1159/000520592 · Cited by 2
Lazarus, G., Dirjayanto, V. J., Sambowo, N. B., & Vianca, E. (2022) · Diabetes & Metabolic Syndrome Clinical Research & Reviews · doi:10.1016/j.dsx.2021.102383 · Cited by 2
Morales, C., Diago, R., Cortés, S., Peixoto, C., Pascual, M. A., Guerriero, S., & Alcázar, J. L. (2020) · EMJ Radiology · doi:10.33590/emjradiol/20-00049 · Cited by 2
Cohen, N. D., Flores‐Ahlschewde, P., Gonzales, G. M., Kahn, S. K., da Silveira, B. P., Bray, J. M., King, E. E., Blair, C. C., & Bordin, A. I. (2022) · Journal of Veterinary Internal Medicine · doi:10.1111/jvim.16438 · Cited by 2
Terayama, T., Taniguchi, T., Imai, R., Anan, K., Yoshida, T., Andō, K., Okamori, S., & Okada, Y. (2021) · Systematic Reviews · doi:10.1186/s13643-021-01869-1 · Cited by 2
Critical Appraisal of Quantitative Research
Cavaleri, R., Bhole, S., & Arora, A. (2018) · Springer eBooks · doi:10.1007/978-981-10-2779-6_120-2 · Cited by 4
Adane, T., & Getawa, S. (2022) · Medicine · doi:10.1097/md.0000000000029538 · Cited by 2
Daqqaq, T. S., & Alhasan, A. S. (2022) · Neurosciences · doi:10.17712/nsj.2022.3.20210146 · Cited by 2
Vranić, L., Nadarević, T., Štimac, D., Fraquelli, M., Manzotti, C., Casazza, G., & Colli, A. (2022) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd015415 · Cited by 2
Kang, H. W., Kang, J. K., Lee, S., & Sim, H. S. (2022) · Eon'eo cheong'gag jang'ae yeon'gu/Communication sciences & disorders · doi:10.12963/csd.22923 · Cited by 3
Ding, C., Jia, J., Bai, G., Zhou, W. Z., & Shan, W. (2022) · Acta Radiologica · doi:10.1177/02841851221134485 · Cited by 2
Ahmadzadeh, K., Abbasi, M. F., Yousefifard, M., & Safari, S. (2022) · The American Journal of Emergency Medicine · doi:10.1016/j.ajem.2022.12.038 · Cited by 2
Coventry, L., Oldrini, I., Novak, A., Dean, B. J. F., & Metcalfe, D. (2022) · Emergency Medicine Journal · doi:10.1136/emermed-2022-rcem2.40 · Cited by 2
Zhao, K., Zhu, X., Zhang, M., Xie, Z., Xu, Y., Wu, S., Liao, P., Lu, H., Shen, W., Fu, C.-C., et al. (2023) · International Journal of Computer Assisted Radiology and Surgery · doi:10.1007/s11548-023-02838-w · Cited by 2
Valverde, E. A., Suárez-Escudero, J. C., Cáceres, M. D. P. O., Agudelo, L. H. L., Vélez, C. M., Borrero, A. M. P., Hernández-Padilla, M. L., & Ramírez, P. B. (2023) · Revista Mexicana de Oftalmología · doi:10.24875/rmo.m22000244 · Cited by 2
Gynecologic Imaging and Reporting Data System for classifying adnexal masses
Alcázar, J. L., RODRIGUEZ-GUZMAN, L., Vara, J., Fernando Amor, L., Linder Díaz, C., & Vaccaro, H. (2023) · Minerva Obstetrics and Gynecology · doi:10.23736/s2724-606x.22.05122-3 · Cited by 3
Induction and Treatment of Polycystic Ovary Syndrome with Plant Extract in Rats: A Systematic Review
Esan, W. S., Akintayo, C. O., Sanya, O., Osiyemi, O. A., Olubayo, G., & Adelekan, A. L. (2023) · European Journal of Medicinal Plants · doi:10.9734/ejmp/2023/v34i21124 · Cited by 2
de Melo, A. K. G., Caparroz, A. L. M. A., de Abreu, M. M., Azevedo, D. C., Hoff, L. S., Kowalski, S. C., Torres, T. M., Barros, S. M., Ferreira, G. A., Monticielo, O. A., et al. (2023) · Revista Brasileira de Reumatologia · doi:10.1186/s42358-023-00293-4 · Cited by 2
Dikici, E., Nguyen, X. V., Takacs, N., & Prevedello, L. M. S. (2023) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2023.106901 · Cited by 3
Abdollahifard, S., Taherifard, E., Sadeghi, A., Farrokhi, A., Cohen‐Gadol, A., & Palmisciano, P. (2023) · World Neurosurgery · doi:10.1016/j.wneu.2023.05.029 · Cited by 3
The Utility of Visual and Spatial Perception Tests in Alzheimer’s Disease: A Systematic Review
Scott, J. P., Murphy, D. F., & Noad, R. (2023) · Dementia and Geriatric Cognitive Disorders · doi:10.1159/000530911 · Cited by 2
Patient self-reported instruments for assessing symptoms in rheumatoid arthritis
Meza-Sánchez, A. V., Ventura‐Ríos, L., & Hernández‐Díaz, C. (2023) · Rheumatology International · doi:10.1007/s00296-023-05355-w · Cited by 2
Cai, P., Yang, B., Zhao, J., Ye, P., & Yang, D. (2023) · Frontiers in Oncology · doi:10.3389/fonc.2023.1207892 · Cited by 3
Development of a quality of life instrument to evaluate oral mucositis in cancer patients
Pereira, N. F., Soares, G. H., Aragão, A. S., Michel‐Crosato, E., & Biazevic, M. G. H. (2023) · Research Society and Development · doi:10.33448/rsd-v12i7.42468 · Cited by 2
Diagnostic accuracy of MUC7 expression for bladder cancer: A systematic review and meta-analysis
Zhang, J., & Zhou, L. (2023) · Medicine · doi:10.1097/md.0000000000034828 · Cited by 2
Boujemaa, S., Suri, G. S., & Kaur, G. (2023) · Journal of Virological Methods · doi:10.1016/j.jviromet.2023.114811 · Cited by 4
Bijelić, V., Potter, B. K., Parkin, P. C., Momoli, F., Liebman, M. F., & Hamid, J. S. (2023) · BMJ Open · doi:10.1136/bmjopen-2023-073783 · Cited by 2
Luo, J., Li, T., & Liu, Y. (2023) · Medical Ultrasonography · doi:10.11152/mu-4124 · Cited by 2
Single breath counting technique to assess pulmonary function: a systematic review and meta-analysis
Delmondes, G. M. B., Couto, N. F. S., Correia, M. G. A., Bonifacio, A., Dias, R. D. F., Bezerra, J., dos Santos, M. A. M., de Barros, M. V. G., Costa, E. C., & Correia, M. A. D. V. (2023) · Journal of Breath Research · doi:10.1088/1752-7163/ad0647 · Cited by 2
“In the end, the quality classification of the studies was given as ‘Low’, ‘High’ or ‘Unclear’ based on specific criteria of this tool [21].”
Gopal, S. H., Gokulakrishnan, G., Kulkarni, M., Fernandes, C. J., & Pammi, M. (2023) · Neonatology · doi:10.1159/000533824 · Cited by 2
Cortie, C. H., Skinner, J. N., Sutiyawan, N., Matthews, J. A., Lee, A., Neale, E. P., Byrne, M. K., Greenberg, D., & Meyer, B. J. (2023) · Journal of Forensic Psychiatry and Psychology · doi:10.1080/14789949.2023.2262446 · Cited by 3
Gene mutations as predictors of central lymph mode metastasis in cN0 PTC : A meta‐analysis
Ji, J., & Shi, X. (2023) · Clinical Genetics · doi:10.1111/cge.14456 · Cited by 2
Artificial Intelligence: Why We Need It and Why We Need to Be Cautious
Wright, L. S. (2023) · Cambridge University Press eBooks · doi:10.1017/9781009052023.006 · Cited by 2
Alshammari, A., Oates, A., Rigby, A. S., & Offiah, A. C. (2023) · Clinical Radiology · doi:10.1016/j.crad.2023.11.014 · Cited by 2
Maniaci, A., Guarino, P., Barillari, M. R., Zompo, M. R. D., Filauro, M., Lionello, M., Mannelli, G., Russo, G., Tascone, M., Topazio, D., et al. (2023) · American Journal of Otolaryngology · doi:10.1016/j.amjoto.2023.104131 · Cited by 2
Quantifying myelin in neonates using magnetic resonance imaging: a systematic literature review
Arshad, N. H., Hassan, H. A., Omar, N. F., & Zainudin, Z. (2023) · Korean Journal of Pediatrics · doi:10.3345/cep.2023.00514 · Cited by 3
“21) The tool includes 14 questions used to assess the risk of bias and applicability in terms of patient selection, index test, reference standard, and flow and timing domains.”
MethodInfluentialCritical reading of scientific arcticles on diagnostic studies
Damkjær, M. W., Hess, S., Gerke, O., Jørgensen, K. J., & Schroll, J. B. (2024) · Ugeskrift for Læger · doi:10.61409/v06230404 · Cited by 2
Point-of-Care Diagnosis of Bladder Cancer With Vibrational Spectroscopy: A Systematic Review
Yim, A., Alberto, M., Sharma, V. J., Wood, B. R., Raman, J., Wong, L., Ischia, J. J., & Bolton, D. M. (2023) · Société Internationale d’Urologie Journal · doi:10.48083/nczw3015 · Cited by 2
The role of 68Ga-Pentixafor PET in Primary Aldosteronism: a systematic review and meta-analysis
Wang, M., Zhang, J., Wu, B., & Zhang, C. (2024) · Clinical and Translational Imaging · doi:10.1007/s40336-023-00610-3 · Cited by 2
Poonchuay, N., Saokaew, S., & Incomenoy, S. (2024) · American Journal of Cardiovascular Drugs · doi:10.1007/s40256-023-00623-3 · Cited by 2
“The risk of bias in selected studies was independently assessed by two reviewers using the modified Quality Assessment of Diagnostic Accuracy Studies (QUADAS-2) tool [22].”
Valizadeh, P., Jannatdoust, P., Shahsavarhaghighi, S., Rouzbahani, M., Golezar, M. H., & Sadighi, N. (2024) · Archives of Breast Cancer · doi:10.32768/abc.202411113-26 · Cited by 2
Banwell, G., Ramos‐Petersen, L., Gatt, A., Gijón-Noguerón, G., & Lopezosa-Reca, E. (2024) · Applied Sciences · doi:10.3390/app14062362 · Cited by 3
Fu, D., Zhao, H., Lan, W., & Li, Y. (2024) · Journal of College of Physicians And Surgeons Pakistan · doi:10.29271/jcpsp.2024.03.336 · Cited by 2
Snow, N. J., Murphy, H. M., Chaves, A. R. D. A., Moore, C. S., & Ploughman, M. (2024) · PeerJ · doi:10.7717/peerj.17155 · Cited by 2
Jamal, F. E., Vey, J. A., Proctor, T., Ishak, A., Schmitt, F. C., & Nikas, I. P. (2024) · Advances in Anatomic Pathology · doi:10.1097/pap.0000000000000454 · Cited by 2
Sheron, V. A., Surenthirakumaran, R., Gooden, T. E., Lip, G. Y. H., Thomas, G. N., Moore, D., Nirantharakumar, K., Kumarendran, B., Subaschandran, K., Shribavan, K., et al. (2024) · PLoS ONE · doi:10.1371/journal.pone.0301729 · Cited by 2
Al-Lami, B. S., Dlshad, B. D., Al-Tawil, Y. N., Majeed, H. H., Ramzi, M., Alasaly, D. R., Alchalabi, T. M., Mustafa, Z. Y., Sarkawt, Z., Chaheen, I. M., et al. (2024) · Journal of medical imaging and radiation sciences · doi:10.1016/j.jmir.2024.04.020 · Cited by 2
Merriman, N. A., Walsh, M. E., O’Regan, N., Carrigan, M., Hickey, P., Brent, L., & Blake, C. M. (2024) · HRB Open Research · doi:10.12688/hrbopenres.13894.1 · Cited by 2
“Risk of bias assessment will be conducted using the Quality Assessment of Diagnostic Accuracy Studies (QUADAS-2) tool 33 .”
Tuut, M. K., Burgers, J. S., de Beer, H., Bindels, P., Bossuyt, P. M., Cals, J., Leeflang, M., Mustafa, R. A., Rippen, H., Schaefer, C., et al. (2024) · Journal of Clinical Epidemiology · doi:10.1016/j.jclinepi.2024.111438 · Cited by 2
Self-citation
Metadata
- Authors
- Whiting, P. F., Rutjes, A. W. S., Westwood, M. E., Mallett, S., Deeks, J. J., Reitsma, J. B., Leeflang, M. M. G., Sterne, J. A. C., Bossuyt, P. M. M., & the QUADAS-2 Group*
- Affiliations
- University of Bern (CH)
- Corresponding author
- Whiting, Penny F.
- ORCID
- Venue
- Annals of Internal Medicine
- Publisher
- American College of Physicians
- Published
- 2011-10-18
- Volume
- 155
- Issue
- 8
- Pages
- 529-536
- ISSN
- 0003-4819 (ISSN-L)
- 1539-3704
- OpenAlex
- W2107638293
- Semantic Scholar
- 8a5d0b5a9271ea14bcb8479bc32d3844a80655b9
- Cited by
- 14,199
- References
- 18
- Citations by year
- 2026: 1484 · 2025: 1569 · 2024: 1524 · 2023: 1305 · 2022: 1420 · 2021: 1514 · 2020: 1245 · 2019: 955 · 2018: 767 · 2017: 637 · 2016: 580 · 2015: 528 · 2014: 363 · 2013: 217 · 2012: 75
- FWCI
- 224.36
- Type
- journal article
- Language
- en
- Open access
- green
- hdl.handle.net
- Licence
- cc-by
- www.acpjournals.org/journal/aim/text-and-data-mining (tdm)
- Locations
- Annals of Internal Medicine (publishedVersion)
- PubMed (publishedVersion)
- Pure Amsterdam UMC (publishedVersion)
- Data Archiving and Networked Services (DANS) (submittedVersion)
- Florence Research (University of Florence) (submittedVersion)
- IRIS UNIMORE (University of Modena and Reggio Emilia) (submittedVersion, cc-by)
- University of Birmingham Research Portal (University of Birmingham) (submittedVersion)
- Bristol Research (University of Bristol) (submittedVersion)
- Funders
- Cancer Research UK
- Topics
- Social Sciences › Decision Sciences › Statistics, Probability and Uncertainty › Meta-analysis and systematic reviews
- Physical Sciences › Mathematics › Statistics and Probability › Statistical Methods in Epidemiology
- Health Sciences › Medicine › Public Health, Environmental and Occupational Health › Clinical practice guidelines implementation
- Keywords
- QUADAS-2, diagnostic accuracy studies, quality assessment, risk of bias, applicability, patient selection, index tests, reference materials, flowcharts, systematic reviews
- MeSH terms
- Diagnosis, Humans, Quality Control, Surveys and Questionnaires, Reference Standards, Review Literature as Topic, Time Factors, Bias, Patient Selection, Evidence-Based Medicine
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
A language model drew the claims from the paper on 2026-11-23, under version 3 of the claim definition (model deepseek-v4.1-flash, prompt extract-v3).
A second model labelled each claim on 2026-11-23 (model jev-1.13-20260917, definition revision gold-guideline-v0.2).
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.