QUADAS-2: A Revised Tool for the Quality Assessment of Diagnostic Accuracy Studies
Open accessThe DOI matches its Crossref record; 18 of the 18 references it cites were found in a registry or an index; none of the 21 sources its claims cite is checked for support yet.
Abstract
In 2003, the QUADAS tool for systematic reviews of diagnostic accuracy studies was developed. Experience, anecdotal reports, and feedback suggested areas for improvement; therefore, QUADAS-2 was developed. This tool comprises 4 domains: patient selection, index test, reference standard, and flow and timing. Each domain is assessed in terms of risk of bias, and the first 3 domains are also assessed in terms of concerns regarding applicability. Signalling questions are included to help judge risk of bias. The QUADAS-2 tool is applied in 4 phases: summarize the review question, tailor the tool and produce review-specific guidance, construct a flow diagram for the primary study, and judge bias and applicability. This tool will allow for more transparent rating of bias and applicability of primary diagnostic accuracy studies.
Overview
CoChat Summary
TL;DR
QUADAS-2 is a revised tool for assessing risk of bias and applicability in diagnostic accuracy studies, developed through a 4-stage evidence-based consensus process. It replaces the original QUADAS “yes/no/unclear” quality rating with domain-level judgments of low, high, or unclear risk of bias and concerns about applicability.
Key findings
- QUADAS-2 separates “quality” into risk of bias and concerns regarding applicability, defining quality as the degree to which diagnostic accuracy estimates avoided bias and the extent to which primary studies are applicable to the review question.
- The tool has 4 key domains—patient selection, index test, reference standard, and flow and timing—with the first 3 also assessed for applicability; it is completed in 4 phases and uses signaling questions to help judge risk of bias.
- Development drew on 4 reviews: 54 diagnostic accuracy reviews published between 2007 and 2009, structured feedback from 64 systematic reviewers who had used QUADAS, 101 studies on sources of bias and variation, and 8 studies evaluating QUADAS; a 1-day consensus meeting had 24 attendees, and piloting occurred in 5 reviews.
- Interrater reliability varied considerably, with better agreement on applicability than on risk of bias; all participants preferred QUADAS-2 to the original tool, but the authors could not currently include criteria for studies comparing multiple index tests because the evidence base was insufficient.
Methods
- Tool development followed Moher and colleagues’ 4-stage approach: define the scope, review the evidence base, hold a face-to-face consensus meeting, and refine through piloting.
- A steering group of 9 experts set the scope; the consensus meeting was held on 21 September 2010 in Birmingham, United Kingdom, with 24 attendees who split into groups of 4 to 6 participants; multiple rounds of piloting used online questionnaires and other feedback, including pairs of reviewers piloting QUADAS-2 in 5 reviews.
- No primary statistical analysis was reported; the work synthesized evidence reviews, consensus decisions, and pilot feedback to produce and refine the tool.
Limitations
- Stated: the authors decided they cannot currently include criteria for assessing studies that compare multiple index tests within QUADAS-2 because of the limited evidence base on risk of bias and sources of variation in such studies, and they plan future work on this topic.
- Stated: piloting showed poor interrater reliability and problems applying the domain on comparative accuracy studies; interrater reliability varied considerably overall, with better agreement on applicability than on risk of bias.
- Evident from the text: full details of the 4 evidence reviews were to be published separately, and the main text reports no quantitative reliability estimates, referring instead to an Appendix Table.
Model-written summary. Check it against the paper before relying on it.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
0 Valid · 0 Not valid · 16 Not checked · 24 Own results and interpretations
In the paper
“In a review on anti-cyclic citrullinated peptide antibodies for diagnosing rheumatoid arthritis (10), we found that some studies enrolled consecutive participants with confirmed diagnoses. In these studies, testing for anticyclic citrullinated peptide antibody showed greater sensitivity than in studies that included patients with suspected disease but an unconfirmed diagnosis (that is, difficult-t”
§ QUADAS-2: A Revised Tool for the Quality Assessment of Diagnostic Accuracy Studies > Signaling question 2: Was a case-control design avoided? Signaling question 3: Did the study avoid inappropriate exclusions?
What the sources say
- Not matchedcites [10]
The reference list we hold has no entry [10].
plainstates an association- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Not matched
A statement the paper makes itself — it cites no source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“Studies that make inappropriate exclusions (for example, not including”
§ QUADAS-2: A Revised Tool for the Quality Assessment of Diagnostic Accuracy Studies > Signaling question 2: Was a case-control design avoided? Signaling question 3: Did the study avoid inappropriate exclusions?
hedgedstates a possible cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
None of the sources cited for this claim could be matched to a paper, so there is nothing to check it against.
In the paper
“Because the accuracy of a test may depend on where it will be used in the diagnostic pathway, review authors are asked to describe patients in terms of setting, intended use of the index test, patient presentation, and previous testing (8,9).”
§ QUADAS-2: A Revised Tool for the Quality Assessment of Diagnostic Accuracy Studies > Phase 1: Review Question
What the sources say
- Not matchedcites [8]
The reference list we hold has no entry [8].
- Not matchedcites [9]
The reference list we hold has no entry [9].
hedgedstates a possible cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Not matched
In the paper
“Development of QUADAS-2 was based on the 4-stage approach proposed by Moher and colleagues (4): define the scope, review the evidence base, hold a face-to-face consensus meeting, and refine the tool through piloting.”
§ QUADAS-2: A Revised Tool for the Quality Assessment of Diagnostic Accuracy Studies > METHODS
What the sources say
- Not matchedcites [4]
The reference list we hold has no entry [4].
plainstates a cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: unclear — It is unclear whether the paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Not matched
None of the sources cited for this claim could be matched to a paper, so there is nothing to check it against.
In the paper
“Studies enrolling participants with known disease and a control group without the condition may similarly exaggerate diagnostic accuracy (7,11).”
§ QUADAS-2: A Revised Tool for the Quality Assessment of Diagnostic Accuracy Studies > Signaling question 2: Was a case-control design avoided? Signaling question 3: Did the study avoid inappropriate exclusions?
What the sources say
- Not matchedcites [7]
The reference list we hold has no entry [7].
- Not matchedcites [11]
The reference list we hold has no entry [11].
hedgedstates a possible cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Not matched
10 more claims
Create a free account to see all 40 claims and every source verdict.
- Probably not a substantial claim. 19
- It may state two separate claims as one. 16
- The quote only partly states this claim. 2
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“We assessed the study-level risk of bias with the QUADAS-2 tool”
In the citing paper
“We developed a revised risk-of-bias assessment tool to address these issues, incorporate advances in assessment of risk of bias used in other recently developed tools, 9 10 and integrate recent developments in estimation of intervention effects from randomised trials. 11”
From RoB 2: a revised tool for assessing risk of bias in randomised trials (2019) · cites this paper as [10]
In the citing paper
“Two reviewers independently assessed the quality of the included studies with the Quality Assessment of Diagnostic Accuracy Studies (Quadas-2) [33].”
From High-standard predictive equations for estimating body composition using bioelectrical impedance analysis: a systematic review (2024) · cites this paper as [33]
In the citing paper
“The quality of the selected studies was rigorously assessed using the Checklist for Artificial Intelligence in Medical Imaging (CLAIM) alongside the Quality Assessment of Diagnostic Accuracy Studies-2 (QUADAS-2).23,24”
From Artificial Intelligence Detection and Segmentation Models: A Systematic Review and Meta-Analysis of Brain Tumors in Magnetic Resonance Imaging (2024) · cites this paper as [24]
In the citing paper
“The methodological quality of each selected study was assessed according to the Quality Assessment of Diagnostic Accuracy Studies (QUADAS-2) checklist [15]”
From The diagnostic accuracy of digital, infrared and mercury-in-glass thermometers in measuring body temperature: a systematic review and network meta-analysis (2021) · cites this paper as [15]
20 more claims about this paper
Create a free account to see every claim other papers make about this one.
Citations
Cites
The Cochrane Collaboration's tool for assessing risk of bias in randomised trials
Higgins, J. P. T., Altman, D. G., Gotzsche, P. C., Juni, P., Moher, D., Oxman, A. D., Savovic, J., Schulz, K. F., Weeks, L., Sterne, J. A. C., et al. (2011) · BMJ · doi:10.1136/bmj.d5928 · Cited by 33,817
Self-citationWhiting, P., Rutjes, A. W., Reitsma, J. B., Bossuyt, P. M., & Kleijnen, J. (2003) · BMC Medical Research Methodology · doi:10.1186/1471-2288-3-25 · Cited by 3,592
Self-citationThe Hazards of Scoring the Quality of Clinical Trials for Meta-analysis
Jüni, P. (1999) · JAMA · doi:10.1001/jama.282.11.1054 · Cited by 1,981
Empirical evidence of design-related bias in studies of diagnostic tests.
Lijmer, J. G. (1999) · JAMA · doi:10.1001/jama.282.11.1061 · Cited by 1,861 · cited 2×
“Studies enrolling participants with known disease and a control group without the condition may similarly exaggerate diagnostic accuracy (7, 11).”
BackgroundGuidance for Developers of Health Research Reporting Guidelines
Moher, D., Schulz, K. F., Simera, I., & Altman, D. G. (2010) · PLoS Medicine · doi:10.1371/journal.pmed.1000217 · Cited by 1,437
Systematic Reviews of Diagnostic Test Accuracy
Leeflang, M. M. G., Deeks, J. J., Gatsonis, C., & Bossuyt, P. M. M. (2008) · Annals of Internal Medicine · doi:10.7326/0003-4819-149-12-200812160-00008 · Cited by 1,124
Self-citationSources of Variation and Bias in Studies of Diagnostic Accuracy: A Systematic Review
Whiting, P., Rutjes, A. W. S., Reitsma, J. B., Glas, A. S., Bossuyt, P. M. M., & Kleijnen, J. (2004) · Annals of Internal Medicine · doi:10.7326/0003-4819-140-3-200402030-00010 · Cited by 798 · cited 4×
“The third review was an update on sources of bias and variation in diagnostic accuracy studies that included 101 studies (7).”
BackgroundInfluentialSelf-citationEvaluation of QUADAS, a tool for the quality assessment of diagnostic accuracy studies
Whiting, P. F., Weswood, M. E., Rutjes, A. W., Reitsma, J. B., Bossuyt, P. N., & Kleijnen, J. (2006) · BMC Medical Research Methodology · doi:10.1186/1471-2288-6-9 · Cited by 769
Self-citationLeeflang, M. M. G., Moons, K. G. M., Reitsma, J. B., & Zwinderman, A. H. (2008) · Clinical Chemistry · doi:10.1373/clinchem.2007.096032 · Cited by 346 · cited 1×
“Test performance is likely to be poorer in an independent sample of patients in whom the same threshold is used (12).”
BackgroundSelf-citationNo role for quality scores in systematic reviews of diagnostic accuracy studies
Whiting, P., Harbord, R., & Kleijnen, J. (2005) · BMC Medical Research Methodology · doi:10.1186/1471-2288-5-19 · Cited by 337
Self-citation
Cited by
Items 13,401–13,500 of 14,770
Kathrikolly, T., Nair, S. N. P., Mathew, A., Saxena, P. P. U., & Nair, S. (2022) · Figshare · doi:10.6084/m9.figshare.21303685
Mai, B., Zhou, L., Wang, Q., Ding, B., Zhan, Y., Qin, S., Zhu, N., Li, Z., & Lei, Z. (2024) · Figshare · doi:10.6084/m9.figshare.26716465
Rapado‐González, Ó., Salta, S., López‐López, R., Henrique, R., Suárez-Cunqueiro, M. M., & Jerónimo, C. (2024) · Figshare · doi:10.6084/m9.figshare.26629043
Yang, Y., Wu, Y., & Zhao, W. (2024) · Figshare · doi:10.6084/m9.figshare.25052351
Li, X., Zhao, D., Xie, J., Wen, H., Liu, C., Li, Y., Li, W., & Wang, S. (2024) · Figshare · doi:10.6084/m9.figshare.24873149
Salta, S., Lobo, J., Magalhães, B., Henrique, R., & Jerónimo, C. (2024) · Figshare · doi:10.6084/m9.figshare.26608167
Kouz, K., Michard, F., Bergholz, A., Vokuhl, C., Briesenick, L., Hoppe, P., Flick, M., Schön, G., & Saugel, B. (2021) · Figshare · doi:10.6084/m9.figshare.14337520
Lin, M., Li, Y.-R., Lan, Q.-W., Long, L.-J., Liu, J.-Q., Chen, Y.-W., Cao, X.-J., Wu, G.-Y., Li, Y.-P., & Guo, X.-G. (2022) · Figshare · doi:10.6084/m9.figshare.20046923
Grubb, M. (2020) · The Atrium (University of Guelph)
Cann, A. J. (2023) · ORCA Online Research @Cardiff (Cardiff University) · Cited by 1
The assessment of neonatal jaundice screening in comparison with blood sampling
Březinová, A., & Anežka, B. (2018) · Czech Technical University Digital Library (Czech Technical University in Prague)
Elbarbary, M. (2022) · TSpace (University of Toronto)
Vázquez-Niebla, J. C. (2023) · Tesis Doctorals en Xarxa (Consorci de Serveis Universitaris de Catalunya)
The assessment and rehabilitation of post stroke dysphagia
Benfield, J. K. (2021) · Nottingham ePrints (University of Nottingham)
Rivera, H. (2023) · LA Referencia (Red Federada de Repositorios Institucionales de Publicaciones Científicas)
Aguilera-Cobos, L. (2023) · Repositorio Institucional de la Universidad de Málaga (University of Málaga)
Weeda, Y. (. (2023) · Research Repository (Delft University of Technology)
Posso, M., & de Pediatria, D. I. G. I. D. M. P. U. A. D. B. D. (2017) · LA Referencia (Red Federada de Repositorios Institucionales de Publicaciones Científicas)
Late enhancement CT (LIE-CT) zur Beurteilung der Myokardvitalität: eine Metaanalyse
Fischer, R. (2023) · Qucosa (Saxon State and University Library Dresden)
Prediction of the Risk of Bleeding in People Living with Hemophilia
Germini, F. (2023) · MacSphere (McMaster University) · doi:10.71548/24251
Accuracy of statistical models for crime linkage and the exploration of sexual offence classes
Kelkar, G. M. (2024) · University of Birmingham Institutional Research Archive (University of Birmingham)
Dynamic Assessment of Spanish-English Speaking Children for Developmental Language Disorder
Neiling, S. L., & Neiling, S. L. (2024) · UA Campus Repository (The University of Arizona)
Säynäjäkangas, S. (2023) · Theseus (Ammattikorkeakoulujen)
Klanjšek, P. (2024) · University of Maribor digital library (University of Maribor) · Cited by 1
Diagnostic values of the slump test for radiculopathy of disc origin: A systematic review.
Laurent, A. (2023) · HAL
Epidemiology and Neuropsychiatry of Catatonia
Rogers, J. P. (2023) · UCL Discovery (University College London)
Camarón Velasco, N. (2024) · UVaDOC UVaDOC University of Valladolid Documentary Repository (University of Valladolid)
Peterson, K. A. (2024) · UEA Digital Repository (University of East Anglia)
Diagnosis and treatment of complicated and uncomplicated appendicitis
Bom, W. J. (2022) · Pure Amsterdam UMC
Novel biomarkers for distinguishing bacterial from non-bacterial infection: a systematic review
Drummond, H., Umana, E., Groves, H., Waterfield, T., & Mills, C. (2024) · Research Portal (Queen's University Belfast)
Villamañán Turrado, M. (2024) · UVaDOC UVaDOC University of Valladolid Documentary Repository (University of Valladolid)
Ligabue, G., Biagini, G., & Besutti, G. (2021) · IRIS UNIMORE (University of Modena and Reggio Emilia) · Cited by 1
Kohli, M. (2023) · eScholarship@McGill (McGill) · doi:10.82308/9744
Karkia, R. (2025) · Brunel University Research Archive (BURA) (Brunel University London)
Guía de Práctica Clínica para el diagnóstico y manejo de la apendicitis aguda
(IETSI), S. S. E. S. (. I. D. E. D. T. E. S. E. I. (2022) · LA Referencia (Red Federada de Repositorios Institucionales de Publicaciones Científicas) · Cited by 1
The diagnostic accuracy of physical signs: practice experience compared with research evidence
Yan, X., Zhang, Y., Xiang, Y., Xu, L., Zhang, D., Xie, F., & Wu, D. (2025) · Medicine Plus · doi:10.1016/j.medp.2025.100093
Optimising Genome Sequencing Data Reanalysis in Patients with Unsolved Primary Immunodeficiencies
Dai, P. (2025) · UNSWorks (University of New South Wales, Sydney, Australia) · doi:10.26190/unsworks/31602
Detection and Classification of Butterfly Species Using Deep Learning: A Systematic ReviewPreprint
Monsalve, N. R. H., Timana, L. C. R., Ciarelli, P. M., de Brito Freire Junior, G., Bastos-Filho, T., & Souza, A. F. D. (2025) · doi:10.17605/osf.io/rbxwy
Yang, H., Zou, Z., Li, Z., Soe, N. N., Ong, J., Latt, P. M., Zhang, Y., Suthakaran, R., & Zhang, L. (2025) · Intelligent Oncology · doi:10.1016/j.intonc.2025.10.002
A Benchmark and Meta-Analysis of Externally Validated AI Models for Cervical Cancer
Hashemi, Z., Pordanjani, B. M., Gharebakhshi, F., Sharif, S., & Hosseini, T. (2025) · InfoScience Trends · doi:10.61882/ist.202502.09.05
Atef Eid, M. E., Ghadah Faleh, S. A., Ibrahim Mousa, M. A. S., Abdurhman, A., Dima Idris, A.-S., Khadijah Mohammed, M. M., Maysoon saud, A., Bandar Hamdan, A., Ahmed Mohammed, R. A., Saeed Gharm Allah, A. A., et al. (2025) · Dialnet (Universidad de la Rioja) · doi:10.5281/zenodo.17530960
Soares, T. D. S., Cristino, A. D. S., Silva, A. D. F., & dos Santos, L. R. (2025) · Einstein (São Paulo) · doi:10.31744/einstein_journal/2025rw1521
Maesa, J. M., Aguilera-Cobos, L., Carmona‐Hidalgo, B., Rodríguez-López, R., & Blasco-Amaro, J. A. (2025) · doi:10.52766/rjsm4328
Microfluidics-Enabled Wearable Biosensing: Materials, Systems, and On-Body Validation
Zhang, Z. (2025) · Journal of Materials Science and Chemical Engineering · doi:10.4236/msce.2025.1312003 · Cited by 1
Dabbagh, A. (2019) · MacSphere (McMaster University) · doi:10.71548/21218
Clinical Utility of the Pronator Quadratus Sign: A Systematic Review and Meta-Analysis
Kadhmawi, I., Rashid, R., Babiker, M., Elbeshbeshy, M., & Magee, C. (2025) · Cureus · doi:10.7759/cureus.99766
Limanda, C. F., Mathlubaa, A., Istikanto, F. H., Sisca, Nabila, Y., Amalia, S. R., Putri, S. A. S., Ilmiani, T. K., Hartanto, E., & Nurfadhila, M. (2025) · Medicinus · doi:10.19166/med.v15i1.10771
Xu, H., Xie, P., Ou, D., Wang, J., Zhou, C., & Zhou, Z. (2025) · Research Square · doi:10.21203/rs.3.rs-8228777/v1
Rahman, S. U., & Khalid, M. (2025) · Cureus · doi:10.7759/cureus.99930
“Methodological quality was assessed using the QUADAS-2 (Quality Assessment of Diagnostic Accuracy Studies-2) tool, which evaluates four domains: patient selection, index test, reference standard, and flow and timing [14].”
MRI safe lower limb traction techniques: a systematic review and novel economic technique
Jain, R. V., Sharma, D., Conte, A., Rahman, S. M., & Simpson, A. I. (2025) · British Journal of Radiology · doi:10.1093/bjr/tqaf319
User experiences of DiTA (dita.org.au): A database of studies of diagnostic test accuracy
Kaizik, M. A., Downie, A., Hancock, M. J., & Herbert, R. (2025) · Brazilian Journal of Physical Therapy · doi:10.1016/j.bjpt.2025.101568
Use of Bioinformatics in Clinical Diagnosis: A Review
Vadgama, H., S, P. Y., S., P. A., & Joshi Sangeeta, B. (2025) · INTERANTIONAL JOURNAL OF SCIENTIFIC RESEARCH IN ENGINEERING AND MANAGEMENT · doi:10.55041/ijsrem55571
Omurbekovich, A. B., Rahim, F., Dinara, M., Qumar, A. B., & Issenova, B. (2025) · Indian Journal of Gynecologic Oncology · doi:10.1007/s40944-025-01086-x
“The Diagnostic Accurate Trial Quality Assessment Tool (QUADAS-2), endorsed by the Cochrane Collaboration, was used to assess the methodological quality of the selected studies [16 ].”
Maimaris, S., Baschiera, G., Sammartino, C., Memoli, G. A., Crisciotti, C., Scarcella, C., Scalvini, D., Schiepatti, A., & Biagi, F. (2025) · Gastrointestinal Endoscopy · doi:10.1016/j.gie.2025.12.275 · Cited by 1
Gordiichuk, P., Мельник, Д. В., Gordiichuk, M., & Калачов, О. В. (2025) · Likarska sprava · doi:10.31640/ls-2025-4-29
Salimi, M., Vadipour, P., Khosravi, A., Salimi, B., Mabani, M., Rostami, P., & Seifi, S. (2025) · Annals of Nuclear Medicine · doi:10.1007/s12149-025-02148-y · Cited by 3
“Quality assessment was conducted utilizing both QUA-DAS-2 [20] and the Methodological Radiomics Score (METRICS) [ 21 ].”
Verma, K., & Kumar, S. (2025) · medRxiv · doi:10.64898/2025.12.20.25342753
Al-Lami, B. S., Yaman, M. E., Saeed, A. O., Mustafa, Z. Y., Chaheen, I. M., Aljuboori, S., Alasaly, D. R., Wlya, R., Alhayderi, N., Bakr, C. M., et al. (2025) · Cureus · doi:10.7759/cureus.100482
“Risk of bias and concerns regarding applicability were assessed using the Quality Assessment of Diagnostic Accuracy Studies-2 (QUADAS-2) tool across the four domains of patient selection, index test, reference standard, and flow and timing [15].”
Mirza, I., Hehir, C. M., Farrell, C., Mirza, A., Lee, M., O’Toole, G., & Molloy, A. P. (2025) · Journal of Surgical Oncology · doi:10.1002/jso.70178
Alabas, M. A., Hakami, N. M., Azyabi, F. Y., Alsayed, H. Y., Idris, M. A., Alshanbari, N. F., Althagafi, N. N., Alabdele, A. H., Alfaidi, M. M., Alabdulrahman, A. A., et al. (2026) · Cureus · doi:10.7759/cureus.100559
Azhideh, A., Chansky, H. A., Mirghaderi, P., Haseli, S., Mansoori, B., Faraji, N., Park, C., Houshi, S., & Chalian, M. (2026) · Diagnostics · doi:10.3390/diagnostics16010136
Halimi, A., Msherghi, A. A. A., Nounou, M. V., Elhabbasi, B. M., Abdulrahman, B., Abouelella, A., Shanab, A., Zakraoui, R., Farrag, A. A., & Elhadi, M. (2026) · European Journal of Radiology · doi:10.1016/j.ejrad.2025.112651
Viscosity Imaging for Detection of Liver Inflammation: A Systematic Review
Kapoor, A. (2025) · International Journal of Gastroenterology · doi:10.11648/j.ijg.20250902.18
Application of Transthoracic and Endobronchial Elastography—A Systematic Review
Kildegaard, C., Nielsen, R. W., Laursen, C. B., Nielsen, A. D., Juul, A. D., An, T. J., Addala, D., & Falster, C. (2026) · Cancers · doi:10.3390/cancers18020190
“Assessment of quality and bias was performed on all included articles by CK and RWN using the Quality Assessment of Diagnostic Accuracy Studies-2 tool, QUADAS-2 [16].”
Systematic literature reviews in trauma research: what is important to know?
Papakostidis, C., & Giannoudis, P. (2026) · Injury · doi:10.1016/j.injury.2026.113014
Gafar, M. A. E., Shetty, S., Aziz, M. Q., Abdelrahman, E. D. A., Eltoom, M. M. A., & Ahmad, B. (2026) · Cureus · doi:10.7759/cureus.100960
Liu, Z., Soria, D., Lai, D. J., Zhang, J., Shergill, S. S., & Ang, C. S. (2026) · Alzheimer s & Dementia Diagnosis Assessment & Disease Monitoring · doi:10.1002/dad2.70244 · Cited by 3
“We assessed the methodological quality of the included studies using the QUADAS-2 tool (QualityAssessment ofDiagnosticAccuracyStud-ies, version 2), 38 which is specifically designed to evaluate the risk of bias in diagnostic accuracy research.”
Hafedh, S. M. B., Ruslan, A. H., Ishaq, R. A. R., Hassan, R., & Maudhah, A. A. (2026) · Research Square · doi:10.21203/rs.3.rs-8474983/v1
Supe, L., & Rizzo, S. (2026) · Tomography · doi:10.3390/tomography12010008 · Cited by 2
Sánchez-Luquez, K. (2023) · LA Referencia (Red Federada de Repositorios Institucionales de Publicaciones Científicas)
Sharma, A., Verma, S., Mahuli, S. A., Motwani, M. B., & Sawhney, H. (2025) · Wiadomości Lekarskie · doi:10.36740/wlek/210558
Neves-Teles, T., de Souza, J. B., & de Almeida, R. M. M. (2026) · Research Square · doi:10.21203/rs.3.rs-8544898/v1
Luo, X., Wang, Z., Lu, D., Wang, Y., Wang, W., Dong, P., Gou, Y., & Yang, Y. (2026) · Frontiers in Oncology · doi:10.3389/fonc.2025.1701122
Efficacy of Ultrasonography in Early Detection of Breast Cancer: A Systematic Review
Farooq, S. M. Y., Asif, M. F., Gilani, S. A., Bilal, S. N., Moazzam, M., & Niazi, Y. (2026) · SN Comprehensive Clinical Medicine · doi:10.1007/s42399-025-02245-z
“Next, the diagnostic accuracy studies were assessed regarding risk of bias with the QUADAS-2 tool [20] that covers the concepts of patient selection, index test, reference standard and flow and tim - ing.”
Gomes, M. D. O. (2024) · LA Referencia (Red Federada de Repositorios Institucionales de Publicaciones Científicas)
Martins, F. B. (2023) · LA Referencia (Red Federada de Repositorios Institucionales de Publicaciones Científicas)
Carapeba, M. D. O. L. (2019) · LA Referencia (Red Federada de Repositorios Institucionales de Publicaciones Científicas)
Utilization of artificial intelligence to diagnose stroke in magnetic resonance imaging
Bojsen, J. A. (2024) · University of Southern Denmark Research Portal (University of Southern Denmark) · doi:10.21996/sjs6-6h63
Amalia, R., Sugianto, I., Yunus, B., & Hidayat, M. F. (2026) · Journal of international oral health · doi:10.4103/jioh.jioh_213_25
Lingawi, S. (2025) · cIRcle (University of British Columbia)
Current Research and Future Development of Neuropsychology
Bala, A., Iwański, S., & Szymaszek, A. (2026) · Frontiers research topics · doi:10.3389/978-2-8325-7331-0
Guedes, I. I. G., Santana, P. S., de Miguel, Á. R., Macías, Á. R., López, F. A. C., & González-Hernández, A. (2026) · Ophthalmologica · doi:10.1159/000550443
Imaging-Based Modalities for Identifying At Risk MASH. A Diagnostic Test Meta-Analysis
Gunalan, S. Z., Law, M. S. N., Kua, Y. X., Yu, Z., Lim, R. Y., Selvakumar, A., Syn, N. L. X., Wijarnpreecha, K., Nah, B. K. Y., Zhang, Z. X., et al. (2026) · The American Journal of Gastroenterology · doi:10.14309/ajg.0000000000003919
Pan, H., Jiang, Z.-H., Chen, H.-Y., Liu, J.-H., Chen, Y.-W., Peng, K., Wu, V., & Hsiao, C.-C. (2026) · BMJ Open · doi:10.1136/bmjopen-2025-100875
Peters, J. L., Shepherd, J., Maund, E., Grigore, B., Woods, L., Lord, J., Scott, D. A., & Hyde, C. (2026) · Health Technology Assessment · doi:10.3310/gjjs3014 · Cited by 2
Chana, J., Baghaei, K., Fagundes, N. C. F., Hareendranathan, A. R., Jaremko, J. L., Twilt, M., & Almeida, F. T. (2026) · International Journal of Dentistry · doi:10.1155/ijod/2825133
“To assess the methodological quality and applicability of the included studies, the Quality Assessment Tool for Diagnostic Accuracy Studies-2 (QUADAS-2) was applied [16].”
Point-of-care ultrasound for hip effusion in children: A systematic review and meta-analysis
Gravel, C. A., Neal, J. T., Dodderer, J. K., Kim, W. G., Bain, P. A., & Shah, S. N. (2026) · The American Journal of Emergency Medicine · doi:10.1016/j.ajem.2026.01.034
Chen, F., Liao, J., Mou, D., Peng, S., & He, X. (2026) · BMJ Open · doi:10.1136/bmjopen-2025-110977
Purnomo, A. E., Kurniawan, A. N., Arjuna, Y. Y. E., Tobing, J. F. L., & Hendra, H. (2026) · Journal of Neurological Surgery Part A Central European Neurosurgery · doi:10.1055/a-2793-1168
Hughes, G. K., Tran, A. V., Marouk, S., Paul, E., & Vassar, M. B. (2026) · Archiv für Pathologische Anatomie und Physiologie und für Klinische Medicin · doi:10.1007/s00428-026-04413-5
“…of results including the use of non-recommended statistical analysis methods, failing to report the number of patients and studies contributing to the meta-analysis, or a total lack of risk of bias assessment – a critical assessment of key study components to determine susceptibility to bias [14].”
Contrast-Enhanced Ultrasound in Obstetrics: A Systematic Review
Lefebvre, J., Dap, M., Fijean, A., & Bertholdt, C. (2026) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2025.12.019
Aljbri, A., You, Q., Aljbri, A., Aljbri, K., Qiao, X., Liu, J., & Shao, H. (2026) · Academic Radiology · doi:10.1016/j.acra.2026.01.007 · Cited by 1
Baiamonte, L., Sera, F., Bellante, G., Ragonese, P., & Salemi, G. (2026) · Journal of Neurology · doi:10.1007/s00415-026-13622-6
“Assessment of risk of bias and reproducibility of included studies was performed using the QUADAS-2 tool, as recommended by the Cochrane collaboration [8, 16].”
Becerra, C. A. G., Gallardo, M. I. A., Garcia, J. E. J., Soltero-Molinar, V., Rivera-Rocha, M. I., Parra-Camaño, L. F., Alba, K. S. A.-D., Garcia-Becerra, N., & García-Gutiérrez, C. M. (2026) · Revista Mexicana de Urología · doi:10.48193/s7g2sh54
Liu, X., Yang, B. X., & Tang, D. (2026) · Biomolecules and Biomedicine · doi:10.17305/bb.2026.13425
Vitreoretinal disease detection using artificial intelligence: a systematic review and meta-analysis
Heidari, Z., Mirghorbani, M., Abounoori, M., Ebrahimibesheli, K., Tabarestani, M., Khabazkhoob, M., Yousefi, S., & Modjtahedi, B. S. (2026) · International Ophthalmology · doi:10.1007/s10792-026-03960-9 · Cited by 1
“Articles that passed the initial screening process were then individually assessed for quality by two reviewers (M.A. and D.S.) using Quality Assessment of Diagnostic Accuracy Studies 2 (QUADAS-2) [130].”
Zorzato, P. C., Simone, G., Vizza, R., CATTIN, B., Ricci, A., Bosco, M., Vizzielli, G., Restaino, S., Chiofalo, B., Laganà, A. S., et al. (2026) · European Journal of Surgical Oncology · doi:10.1016/j.ejso.2026.111449
Metadata
- Authors
- Whiting, P. F., Rutjes, A. W. S., Westwood, M. E., Mallett, S., Deeks, J. J., Reitsma, J. B., Leeflang, M. M. G., Sterne, J. A. C., Bossuyt, P. M. M., & the QUADAS-2 Group*
- Affiliations
- University of Bern (CH)
- Corresponding author
- Whiting, Penny F.
- ORCID
- Venue
- Annals of Internal Medicine
- Publisher
- American College of Physicians
- Published
- 2011-10-18
- Volume
- 155
- Issue
- 8
- Pages
- 529-536
- ISSN
- 0003-4819 (ISSN-L)
- 1539-3704
- OpenAlex
- W2107638293
- Semantic Scholar
- 8a5d0b5a9271ea14bcb8479bc32d3844a80655b9
- Cited by
- 14,199
- References
- 18
- Citations by year
- 2026: 1484 · 2025: 1569 · 2024: 1524 · 2023: 1305 · 2022: 1420 · 2021: 1514 · 2020: 1245 · 2019: 955 · 2018: 767 · 2017: 637 · 2016: 580 · 2015: 528 · 2014: 363 · 2013: 217 · 2012: 75
- FWCI
- 224.36
- Type
- journal article
- Language
- en
- Open access
- green
- hdl.handle.net
- Licence
- cc-by
- www.acpjournals.org/journal/aim/text-and-data-mining (tdm)
- Locations
- Annals of Internal Medicine (publishedVersion)
- PubMed (publishedVersion)
- Pure Amsterdam UMC (publishedVersion)
- Data Archiving and Networked Services (DANS) (submittedVersion)
- Florence Research (University of Florence) (submittedVersion)
- IRIS UNIMORE (University of Modena and Reggio Emilia) (submittedVersion, cc-by)
- University of Birmingham Research Portal (University of Birmingham) (submittedVersion)
- Bristol Research (University of Bristol) (submittedVersion)
- Funders
- Cancer Research UK
- Topics
- Social Sciences › Decision Sciences › Statistics, Probability and Uncertainty › Meta-analysis and systematic reviews
- Physical Sciences › Mathematics › Statistics and Probability › Statistical Methods in Epidemiology
- Health Sciences › Medicine › Public Health, Environmental and Occupational Health › Clinical practice guidelines implementation
- Keywords
- QUADAS-2, diagnostic accuracy studies, quality assessment, risk of bias, applicability, patient selection, index tests, reference materials, flowcharts, systematic reviews
- MeSH terms
- Diagnosis, Humans, Quality Control, Surveys and Questionnaires, Reference Standards, Review Literature as Topic, Time Factors, Bias, Patient Selection, Evidence-Based Medicine
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
A language model drew the claims from the paper on 2026-11-23, under version 3 of the claim definition (model deepseek-v4.1-flash, prompt extract-v3).
A second model labelled each claim on 2026-11-23 (model jev-1.13-20260917, definition revision gold-guideline-v0.2).
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.