QUADAS-2: A Revised Tool for the Quality Assessment of Diagnostic Accuracy Studies
Open accessThe DOI matches its Crossref record; 18 of the 18 references it cites were found in a registry or an index; none of the 21 sources its claims cite is checked for support yet.
Abstract
In 2003, the QUADAS tool for systematic reviews of diagnostic accuracy studies was developed. Experience, anecdotal reports, and feedback suggested areas for improvement; therefore, QUADAS-2 was developed. This tool comprises 4 domains: patient selection, index test, reference standard, and flow and timing. Each domain is assessed in terms of risk of bias, and the first 3 domains are also assessed in terms of concerns regarding applicability. Signalling questions are included to help judge risk of bias. The QUADAS-2 tool is applied in 4 phases: summarize the review question, tailor the tool and produce review-specific guidance, construct a flow diagram for the primary study, and judge bias and applicability. This tool will allow for more transparent rating of bias and applicability of primary diagnostic accuracy studies.
Overview
CoChat Summary
TL;DR
QUADAS-2 is a revised tool for assessing risk of bias and applicability in diagnostic accuracy studies, developed through a 4-stage evidence-based consensus process. It replaces the original QUADAS “yes/no/unclear” quality rating with domain-level judgments of low, high, or unclear risk of bias and concerns about applicability.
Key findings
- QUADAS-2 separates “quality” into risk of bias and concerns regarding applicability, defining quality as the degree to which diagnostic accuracy estimates avoided bias and the extent to which primary studies are applicable to the review question.
- The tool has 4 key domains—patient selection, index test, reference standard, and flow and timing—with the first 3 also assessed for applicability; it is completed in 4 phases and uses signaling questions to help judge risk of bias.
- Development drew on 4 reviews: 54 diagnostic accuracy reviews published between 2007 and 2009, structured feedback from 64 systematic reviewers who had used QUADAS, 101 studies on sources of bias and variation, and 8 studies evaluating QUADAS; a 1-day consensus meeting had 24 attendees, and piloting occurred in 5 reviews.
- Interrater reliability varied considerably, with better agreement on applicability than on risk of bias; all participants preferred QUADAS-2 to the original tool, but the authors could not currently include criteria for studies comparing multiple index tests because the evidence base was insufficient.
Methods
- Tool development followed Moher and colleagues’ 4-stage approach: define the scope, review the evidence base, hold a face-to-face consensus meeting, and refine through piloting.
- A steering group of 9 experts set the scope; the consensus meeting was held on 21 September 2010 in Birmingham, United Kingdom, with 24 attendees who split into groups of 4 to 6 participants; multiple rounds of piloting used online questionnaires and other feedback, including pairs of reviewers piloting QUADAS-2 in 5 reviews.
- No primary statistical analysis was reported; the work synthesized evidence reviews, consensus decisions, and pilot feedback to produce and refine the tool.
Limitations
- Stated: the authors decided they cannot currently include criteria for assessing studies that compare multiple index tests within QUADAS-2 because of the limited evidence base on risk of bias and sources of variation in such studies, and they plan future work on this topic.
- Stated: piloting showed poor interrater reliability and problems applying the domain on comparative accuracy studies; interrater reliability varied considerably overall, with better agreement on applicability than on risk of bias.
- Evident from the text: full details of the 4 evidence reviews were to be published separately, and the main text reports no quantitative reliability estimates, referring instead to an Appendix Table.
Model-written summary. Check it against the paper before relying on it.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
0 Valid · 0 Not valid · 16 Not checked · 24 Own results and interpretations
In the paper
“In a review on anti-cyclic citrullinated peptide antibodies for diagnosing rheumatoid arthritis (10), we found that some studies enrolled consecutive participants with confirmed diagnoses. In these studies, testing for anticyclic citrullinated peptide antibody showed greater sensitivity than in studies that included patients with suspected disease but an unconfirmed diagnosis (that is, difficult-t”
§ QUADAS-2: A Revised Tool for the Quality Assessment of Diagnostic Accuracy Studies > Signaling question 2: Was a case-control design avoided? Signaling question 3: Did the study avoid inappropriate exclusions?
What the sources say
- Not matchedcites [10]
The reference list we hold has no entry [10].
plainstates an association- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Not matched
A statement the paper makes itself — it cites no source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“Studies that make inappropriate exclusions (for example, not including”
§ QUADAS-2: A Revised Tool for the Quality Assessment of Diagnostic Accuracy Studies > Signaling question 2: Was a case-control design avoided? Signaling question 3: Did the study avoid inappropriate exclusions?
hedgedstates a possible cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
None of the sources cited for this claim could be matched to a paper, so there is nothing to check it against.
In the paper
“Because the accuracy of a test may depend on where it will be used in the diagnostic pathway, review authors are asked to describe patients in terms of setting, intended use of the index test, patient presentation, and previous testing (8,9).”
§ QUADAS-2: A Revised Tool for the Quality Assessment of Diagnostic Accuracy Studies > Phase 1: Review Question
What the sources say
- Not matchedcites [8]
The reference list we hold has no entry [8].
- Not matchedcites [9]
The reference list we hold has no entry [9].
hedgedstates a possible cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Not matched
In the paper
“Development of QUADAS-2 was based on the 4-stage approach proposed by Moher and colleagues (4): define the scope, review the evidence base, hold a face-to-face consensus meeting, and refine the tool through piloting.”
§ QUADAS-2: A Revised Tool for the Quality Assessment of Diagnostic Accuracy Studies > METHODS
What the sources say
- Not matchedcites [4]
The reference list we hold has no entry [4].
plainstates a cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: unclear — It is unclear whether the paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Not matched
None of the sources cited for this claim could be matched to a paper, so there is nothing to check it against.
In the paper
“Studies enrolling participants with known disease and a control group without the condition may similarly exaggerate diagnostic accuracy (7,11).”
§ QUADAS-2: A Revised Tool for the Quality Assessment of Diagnostic Accuracy Studies > Signaling question 2: Was a case-control design avoided? Signaling question 3: Did the study avoid inappropriate exclusions?
What the sources say
- Not matchedcites [7]
The reference list we hold has no entry [7].
- Not matchedcites [11]
The reference list we hold has no entry [11].
hedgedstates a possible cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Not matched
10 more claims
Create a free account to see all 40 claims and every source verdict.
- Probably not a substantial claim. 19
- It may state two separate claims as one. 16
- The quote only partly states this claim. 2
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“We assessed the study-level risk of bias with the QUADAS-2 tool”
In the citing paper
“We developed a revised risk-of-bias assessment tool to address these issues, incorporate advances in assessment of risk of bias used in other recently developed tools, 9 10 and integrate recent developments in estimation of intervention effects from randomised trials. 11”
From RoB 2: a revised tool for assessing risk of bias in randomised trials (2019) · cites this paper as [10]
In the citing paper
“Two reviewers independently assessed the quality of the included studies with the Quality Assessment of Diagnostic Accuracy Studies (Quadas-2) [33].”
From High-standard predictive equations for estimating body composition using bioelectrical impedance analysis: a systematic review (2024) · cites this paper as [33]
In the citing paper
“The quality of the selected studies was rigorously assessed using the Checklist for Artificial Intelligence in Medical Imaging (CLAIM) alongside the Quality Assessment of Diagnostic Accuracy Studies-2 (QUADAS-2).23,24”
From Artificial Intelligence Detection and Segmentation Models: A Systematic Review and Meta-Analysis of Brain Tumors in Magnetic Resonance Imaging (2024) · cites this paper as [24]
In the citing paper
“The methodological quality of each selected study was assessed according to the Quality Assessment of Diagnostic Accuracy Studies (QUADAS-2) checklist [15]”
From The diagnostic accuracy of digital, infrared and mercury-in-glass thermometers in measuring body temperature: a systematic review and network meta-analysis (2021) · cites this paper as [15]
20 more claims about this paper
Create a free account to see every claim other papers make about this one.
Citations
Cites
The Cochrane Collaboration's tool for assessing risk of bias in randomised trials
Higgins, J. P. T., Altman, D. G., Gotzsche, P. C., Juni, P., Moher, D., Oxman, A. D., Savovic, J., Schulz, K. F., Weeks, L., Sterne, J. A. C., et al. (2011) · BMJ · doi:10.1136/bmj.d5928 · Cited by 33,817
Self-citationWhiting, P., Rutjes, A. W., Reitsma, J. B., Bossuyt, P. M., & Kleijnen, J. (2003) · BMC Medical Research Methodology · doi:10.1186/1471-2288-3-25 · Cited by 3,592
Self-citationThe Hazards of Scoring the Quality of Clinical Trials for Meta-analysis
Jüni, P. (1999) · JAMA · doi:10.1001/jama.282.11.1054 · Cited by 1,981
Empirical evidence of design-related bias in studies of diagnostic tests.
Lijmer, J. G. (1999) · JAMA · doi:10.1001/jama.282.11.1061 · Cited by 1,861 · cited 2×
“Studies enrolling participants with known disease and a control group without the condition may similarly exaggerate diagnostic accuracy (7, 11).”
BackgroundGuidance for Developers of Health Research Reporting Guidelines
Moher, D., Schulz, K. F., Simera, I., & Altman, D. G. (2010) · PLoS Medicine · doi:10.1371/journal.pmed.1000217 · Cited by 1,437
Systematic Reviews of Diagnostic Test Accuracy
Leeflang, M. M. G., Deeks, J. J., Gatsonis, C., & Bossuyt, P. M. M. (2008) · Annals of Internal Medicine · doi:10.7326/0003-4819-149-12-200812160-00008 · Cited by 1,124
Self-citationSources of Variation and Bias in Studies of Diagnostic Accuracy: A Systematic Review
Whiting, P., Rutjes, A. W. S., Reitsma, J. B., Glas, A. S., Bossuyt, P. M. M., & Kleijnen, J. (2004) · Annals of Internal Medicine · doi:10.7326/0003-4819-140-3-200402030-00010 · Cited by 798 · cited 4×
“The third review was an update on sources of bias and variation in diagnostic accuracy studies that included 101 studies (7).”
BackgroundInfluentialSelf-citationEvaluation of QUADAS, a tool for the quality assessment of diagnostic accuracy studies
Whiting, P. F., Weswood, M. E., Rutjes, A. W., Reitsma, J. B., Bossuyt, P. N., & Kleijnen, J. (2006) · BMC Medical Research Methodology · doi:10.1186/1471-2288-6-9 · Cited by 769
Self-citationLeeflang, M. M. G., Moons, K. G. M., Reitsma, J. B., & Zwinderman, A. H. (2008) · Clinical Chemistry · doi:10.1373/clinchem.2007.096032 · Cited by 346 · cited 1×
“Test performance is likely to be poorer in an independent sample of patients in whom the same threshold is used (12).”
BackgroundSelf-citationNo role for quality scores in systematic reviews of diagnostic accuracy studies
Whiting, P., Harbord, R., & Kleijnen, J. (2005) · BMC Medical Research Methodology · doi:10.1186/1471-2288-5-19 · Cited by 337
Self-citation
Cited by
Items 13,501–13,600 of 14,770
Han, J.-Y., Li, Y., Xia, X., Wang, S.-W., Chen, Y.-Z., Sun, M.-L., Xing, J., Zhong, Y., Wu, X., & Yao, J. (2026) · International Journal of Legal Medicine · doi:10.1007/s00414-026-03724-1
Caballero-Vázquez, A., Garcia-Cerezo, M., Fernandez-Castro, L. R., Morales-García, C., Ramos‐Bossini, A. J. L., Vergara-Rubio, F., Ortega, F. G., & Sanchez-Maldonado, J. M. (2026) · Discover Oncology · doi:10.1007/s12672-025-03646-1
“6) [22].”
Diagnostic tests for autism spectrum disorder (ASD) in preschool children
Brignell, A., Chan, K., Chellew, T., Maddumahewa, C. V., Wong, N. X. H., Hooft, L., Alshawsh, M. A., & Williams, K. J. (2026) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd016321
Cecibel, B. L. R., Cambizaca, R. P. D., & Carreño, J. P. B. (2026) · Ibero Ciencias - Revista Científica y Académica · doi:10.63371/ic.v5.n1.a648
Luijendijk, C. D., van Eck, H. M. H., van der Pol, P., Zwaga, A., Kiewiet, R. M., Vermeer, H. J., Akerboom, B. M. C., & Boer, G. M. N.-D. (2026) · BMC Pregnancy and Childbirth · doi:10.1186/s12884-026-08681-6
Deep learning for early diagnosis of uveal melanoma: a systematic review and meta-analysis
de Moraes, F. C. A., Matheus, G. T. F. U., Dichtl, Í. L. D. B., Kreuz, M., da Silva, E. R., & Burbano, R. M. R. (2026) · Clinical & Translational Oncology · doi:10.1007/s12094-025-04187-3
“…on independent cohorts; reference Standard, which appraises the accuracy and consistency of the ground truth; and flow and timing, which considers the sequence and timing of data collection, AI inference, and reference assessment, as well as the management of missing or excluded cases [19, 20].”
Meng, X., Wen, Y., Wang, X., Yang, X., & Gao, L. (2026) · Frontiers in Cardiovascular Medicine · doi:10.3389/fcvm.2026.1620841
Alanazi, F. S. Z., Alshamrani, A. A. A., Atawi, F. A. A., Aljohani, R., Marshed, Z. M., Alghamdi, B. M., & Aljuaid, O. M. (2026) · Journal of Clinical Practice and Medical Research · doi:10.59324/jcpmr.2026.2(1).16
de Alencar, J. N., Scheffer, M. K., Correia, B. P., Franchini, K. G., Felicioni, S. P., & Marchi, M. F. N. D. (2026) · doi:10.22533/at.ed.127112613013
“The risk of bias was assessed using the Quality Assessment of Diagnostic Accuracy Studies-2 Revised (QUADAS-2) tool [14,15].”
Ataw, S. A. E. A., Alshehri, M. M., Alanazi, T. T., Alruwaili, A. M., Alanazi, A. D. S., Alanzi, B. M., Alatawi, M. O., Al-Harbi, F. M., Alsawat, H. M., Albalawi, R. A., et al. (2025) · Journal of Clinical Practice and Medical Research · doi:10.59324/jcpmr.2025.1(3).27
Ntzani, E., Tsarapatsani, K., Asimakopoulos, G.-A., Jalal, H. J., Kang, S. K., Trikalinos, T. A., & CISNET Bladder Cancer Modeling Investigators (2026) · medRxiv · doi:10.64898/2026.02.02.26344871
Palanivelu, S., & SHUNMUGAVELU, K. (2024) · Student s Journal of Health Research Africa · doi:10.51168/sjhrafrica.v5i12.2415
Huang, J., Niu, T., & Shi, H. (2026) · Frontiers in Medicine · doi:10.3389/fmed.2025.1686137 · Cited by 1
Systematic Reviews of Diagnostic Studies
Hosseini, M., & Akbarzadeh, M. A. (2026) · IGI Global eBooks · doi:10.4018/979-8-3693-3007-4.ch003
Kanani, F., Riyad, N., Ewidat, O., Maraqah, M., Bder, F., Iserlis, A., Zoabi, N., Messer, N., & Neeman, R. (2026) · The American Surgeon · doi:10.1177/00031348261423912
“The methodological quality of included studies was assessed using the Quality Assessment of Diagnostic Accuracy Studies-2 (QUADAS-2) tool, 14 which evaluates risk of bias across 4 domains: patient selection, index test, reference standard, and fl ow and timing.”
Shahzad, H., Sulaiman, H., Roheel, A., Tahir, H. N., Tahir, M., Tariq, M., & Sulaiman, H. (2026) · Exploration of Cardiology · doi:10.37349/ec.2026.101293
Li, X., Cheung, R., Nayeni, M., Al-Burak, S. A., Dave, P., Li, B., & Malvankar‐Mehta, M. S. (2026) · Canadian Journal of Ophthalmology · doi:10.1016/j.jcjo.2026.01.005
Chattopadhyay, C., Chouhan, C., Deo, V., Patel, M., Garg, A., & Airun, P. (2025) · Research Square · doi:10.21203/rs.3.rs-7366245/v1
MicroRNAs as a Diagnostic Tool in Bacterial Infections: A Review Article
Al-yozbakee, Z. M., Hamdoon, A. M., & Khaleel, Z. K. (2026) · Al-Rafidain Journal of Medical Sciences · doi:10.54133/ajms.v10i1.2642
“QUADAS-2 was used to assess diagnostic accuracy studies [51,52], covering risk of bias and relevance in 4 areas: patient selection, index test, reference standard, and flow/time.”
Alsabri, M., Rath, S., Elkarargy, M. A., Aboali, A. A., Elsnhory, A. B., Ezz, M. H., & Lusinski, E. (2026) · Scandinavian Journal of Trauma Resuscitation and Emergency Medicine · doi:10.1186/s13049-026-01578-5
Alqurain, A., Mashat, L. F., Alshammari, N. M., AL-Sumaily, H. A., Alamer, A. M., Aldhmadi, R. S., Albalawi, M. D., Alghamdi, N. S., & Metwaly, A. S. (2026) · Cureus · doi:10.7759/cureus.103240
“…quality and potential risk of bias in the included diagnostic accuracy studies, the Quality Assessment of Diagnostic Accuracy Studies-2 (QUADAS-2) tool [17] was utilized, as it evaluates bias across four key domains: patient selection, index test, reference standard, and flow and timing.”
Ye, F., Zhou, Q., & Zhang, S. (2026) · International Dental Journal · doi:10.1016/j.identj.2026.109421
“Two investigators (FFY and QZ) assessed the risk of bias of the eligible studies using the Quality Assessment of Diagnostic Accuracy Studies 2 (QUADAS-2) tool, 26 and disagreements were resolved by discussing with a third investigator (SYZ).”
Radiology Surveillance for Breast Cancer Survivors: A Systematic Review and Meta-Analysis
Icanervilia, A. V., Choridah, L., Febiyanti, A. M. G., Kuncoro, A. A. L., Agustyana, S. N., & Nugroho, D. B. (2026) · Asian Pacific Journal of Cancer Prevention · doi:10.31557/apjcp.2026.27.2.433
“For studies focused on diagnostic accuracy, the QUADAS-2 (Quality Assessment of Diagnostic Accuracy Studies 2) checklist was employed to evaluate the study quality [14].”
Investigating prevention, diagnosis and impact of surgical site infection
Lathan, R. (2025) · Repository@Hull (Worktribe) (University of Hull)
de Alencar, J. N., Scheffer, M. K., Correia, B. P., Franchini, K. G., Felicioni, S. P., & Marchi, M. F. N. D. (2026) · Revista Brasileira de Saúde · doi:10.22533/at.ed.82082326280112
Asmundo, L., Zanardo, M., Albano, D., Basile, M., Cressoni, M., Prato, A., Sardanelli, F., Sconfienza, L. M., & Vitali, P. (2026) · La radiologia medica · doi:10.1007/s11547-026-02180-6
“Another researcher (M.B.) with 4 years’ experience in neuroimaging reviewed the quality of the included articles, using the QualSyst tool [11], using the checklist for qualitative studies, and QUADAS 2 tool [12] for only the diagnostic test accuracy (DTA) articles included.”
Wang, R., Zhao, W., Lv, B., Lei, Q., Tian, X., Guo, Y., & Wang, Y. (2026) · Heart · doi:10.1136/heartjnl-2025-327108
Zhou, H., Chen, X., Gao, B., & Feng, X. (2026) · BMC Medical Imaging · doi:10.1186/s12880-026-02177-7
“Methodological quality was evaluated using the Quality Assessment of Diagnostic Accuracy Studies 2 (QUA-DAS-2) tool [18], assessing risk of bias and applicability concerns across four domains: patient selection, index test, reference standard, and flow and timing.”
Cedeño, S. D. G., Escudero-Doltz, W. S., Aráuz, S. M. L., & Noboa, R. A. S. (2026) · RECIAMUC · doi:10.26820/reciamuc/10.(1).oct.2026.2-18
Choudhary, S., Kanaujia, R., Bahadur, R., & Angrup, A. (2026) · European Spine Journal · doi:10.1007/s00586-026-09805-4
“The Quality Assessment of Diagnostic Accuracy Studies (QUADAS-2) tool was used to evaluate the qualities of included studies [13].”
Visuddho, V., Aldian, F. M., Hartanto, J. O., Witarto, B. S., Sampurna, M. T. A., Utomo, M. T., Etika, R., Angelika, D., Handayani, K. D., Ayuningtyas, W., et al. (2025) · Acta bio-medica dell'Ateneo parmense/Acta biomedica · doi:10.23750/abm.v96i2.16929
Nmai, R. A., Wiafe, Y. A., Donkor, A., Anyitey-Kokor, I. C., Adu-Bredu, T. K., Antwi, S. O., & Roberts, L. R. (2026) · Journal of Ultrasound · doi:10.1007/s40477-026-01121-3
Diagnostiquer l'épilepsie à l'aide de l'apprentissage machine appliqué à l'électroencéphalogramme
Lemoine, É. (2025) · PolyPublie (École Polytechnique de Montréal)
Subramani, P., & Shunmugavelu, K. (2023) · Student s Journal of Health Research Africa · doi:10.51168/sjhrafrica.v4i12.2449
Lu, Y., Gao, X., Wang, X., Wang, W., & Xu, J. (2026) · The Journal of Laryngology & Otology · doi:10.1017/s002221512610437x
Hadke, P., & Patil, S. (2025) · IEEE International Conference on Blockchain and Distributed Systems Security (ICBDS) · doi:10.1109/icbds67396.2025.11376708
“Quality of studies was appraised with an adjusted Quality Assessment of Diagnostic Accuracy Studies (QUADAS-2) framework refined for studies of health applications of machine learning [10].”
Chen, C., Hsiao, K., Lu, S., Bai, C., Wen, K., & Wang, Y. H. (2026) · Journal of Lower Genital Tract Disease · doi:10.1097/lgt.0000000000000936
Lai, J. T. F., Cheng, K., Eliahoo, J., Gibb, I. E., Frith, D., Masouros, S. D., & Hettiaratchy, S. P. (2026) · The Journal of Trauma: Injury, Infection, and Critical Care · doi:10.1097/ta.0000000000004891
Lin, J., Ji, Z., Lin, X. C., Yan, Y., Zheng, T., Zhang, H., Wu, Y., Wang, Y., Yu, Z., Haibo, D., et al. (2026) · Frontiers in Neurology · doi:10.3389/fneur.2026.1760363
“Eligible trials were appraised using the QUADAS-2 checklist (Supplementary material) and its comparative extension (QUADAS-C) across four domains: patient selection, index test, reference standard, and flow/timing (28, 29).”
Ji, W., & Shi, Y. (2026) · Frontiers in Medicine · doi:10.3389/fmed.2025.1736860
“…of lesions, time interval to reference standard, primary clinical context); and (3) details of the The methodological quality and risk of bias of the included studies were assessed independently by two investigators using the Quality Assessment of Diagnostic Accuracy Studies 2 (QUADAS-2) tool (12).”
Manceau, C., Bento, L., Brunelle, S., Prudhomme, T., Bajeot, A. S., Gamé, X., Soulie, M., Delchier, M. C., Mokrane, F., & Roumiguié, M. (2026) · Frontiers in Oncology · doi:10.3389/fonc.2026.1563391
“We evaluated the methodological quality applied to four “ risk of bias ” domains and three “ concerns regarding applicability ” domains according to the Quality Assessment of Diagnostic Accuracy Studies 2 (QUADAS-2) tool (25).”
Kallala, D., Venkat Narsaiah Sushanth Gajavelli, M. B. B. S., Pidikiti, C. V., Somagani, R., & Sacras, I. (2026) · Research Square · doi:10.21203/rs.3.rs-8905316/v1
Rebuttal to correspondence on “Diagnostic accuracy meta-analysis of portal vein thrombosis imaging”
Girardi, L., & Delluc, A. (2026) · Thrombosis Research · doi:10.1016/j.thromres.2026.109628
Personalized Parenteral Nutrition—Comparing Apples and Oranges?
Bhattacharjee, A., Pal, G., & Kundu, R. (2026) · Indian Journal of Critical Care Medicine · doi:10.5005/jp-journals-10071-25128
Li, Q., Liu, H., & Wang, J. (2026) · Technology in Cancer Research & Treatment · doi:10.1177/15330338261425328 · Cited by 1
Salivary biomarkers for oral cancer screening: A review
Singh, P., & Vaidya, R. (2026) · Journal of Scientific Advances in Dentistry · doi:10.65929/jsad.2026.1.1.004
Tiwari, S., Pradhan, A., Koh, E., Solanki, N. S., Wagstaff, M. J. D., & Concannon, E. (2026) · Journal of Plastic Reconstructive & Aesthetic Surgery · doi:10.1016/j.bjps.2026.02.029
Serafim, A. J. F., MARTINS, B. L. F., Souza, J. R., Schwabe, M. E. G., Tesk, M. S., Morais, N., Rondon, N. C. N., de Oliveira, T. I. C., de Souza, T. J., & de Figueiredo, V. V. (2026) · Brazilian Journal of Implantology and Health Sciences · doi:10.36557/2674-8169.2026v8n2p1107-1127
Ullah, A., Mustafa, G., Liu, J., Peng, S., Yin, Y., Wu, S., & Fu, Y. (2026) · Cancers · doi:10.3390/cancers18050720
Guía de práctica clínica sobre Diabetes Mellitus Tipo 1
(2026) · GuíaSalud eBooks · doi:10.46995/gpc_659
Manurung, H. E., Budiman, F., Santoso, H. A., & Marjuni, A. (2025) · International Conference on Information System & Information Technology (ICISIT) · doi:10.1109/icisit66233.2025.11402942
“The escalating volume of medical imaging data, with millions of images generated globally on a daily basis, underscores the necessity of CNNs to mitigate challenges associated with manual interpretation, including inter-observer variability [24].”
Points for clear interpretation of AI-assisted 18 F-FDG PET/CT in breast cancer
Altundağ, K. (2026) · Annals of Nuclear Medicine · doi:10.1007/s12149-026-02182-4
Diagnostic accuracy of ELISA in sporotrichosis: A systematic review and meta-analysis
de Almeida, D. M., Messenburger, G. P., Bierhals, E. S., Jorge, S., & Nobre, M. D. O. (2026) · Revista Iberoamericana de Micología · doi:10.1016/j.riam.2025.11.002
Darabi, M. H., Arora, H., Shekouhi, R., Hoffman, H., Forghani, R., & Farhadi, H. F. (2026) · European Spine Journal · doi:10.1007/s00586-026-09838-9
“Two reviewers independently assessed the bias risk of the included studies using the Quality Assessment of Diagnostic Accuracy Studies-2 (QUADAS-2) [ 26 ].”
Keller, S., Zeidan, Y., Sigl, J., Dieker, W., NAUMER, L., Amendt, K., & Sigl, M. (2026) · In Vivo · doi:10.21873/invivo.14232
Lie, H., Prasetyo, S. A., Purnama, A. A., & Irawan, A. (2026) · European Journal of Gastroenterology & Hepatology · doi:10.1097/meg.0000000000003091
Emal, M. (2025) · Pure Amsterdam UMC
Moving test accuracy research forward
Lee, J. (2023) · Pure Amsterdam UMC
Sirtautaitė, G. (2025) · Lithuanian University of Health Sciences
Sánchez, J. B. (2026) · Tesis Doctorals en Xarxa (Consorci de Serveis Universitaris de Catalunya)
Urso, D., Giannoni‐Luza, S., Ionta, S., Mondello, S., & Logroscino, G. (2026) · Alzheimer s & Dementia Diagnosis Assessment & Disease Monitoring · doi:10.1002/dad2.70266
“We tailored the Quality Assessment of Diagnostic Accuracy Studies (QUADAS-2) tool 23 (Table S4”
Doozandeh, A., Hatami, M., Khorrami, Z., Sadatmoosavi, A., Farjami, M., & Soltani, G. (2026) · Journal of Ophthalmic and Vision Research · doi:10.18502/jovr.v21.18852
Reporting and critical appraisal of evidence-based research: Making the journal club most effective
Das, R., & Bang, A. (2026) · Indian Journal of Pharmacology · doi:10.4103/ijp.ijp_570_25 · Cited by 1
“[14] It has 4 domains that include patient selection, index test, reference standard, and flow/timing.”
Hasbi, R., Brotons, A., Gall, M. L., Dorison-Bachet, D., Urena, R., & Philip-Alliez, C. (2026) · International Journal of Oral and Maxillofacial Surgery · doi:10.1016/j.ijom.2026.02.016
Laidlaw, M., Reid, M., Rajiv, S., & Gérard, J. (2026) · Tomography · doi:10.3390/tomography12030032
Fanni, S. C., Damone, F., Korakas, M., Lencioni, R. A., Brunetto, M. R., Neri, E., Cioni, D., Masala, S. A., & Scaglione, M. (2026) · Diagnostics · doi:10.3390/diagnostics16050743
Sabella-Jiménez, V. L., Sabella‐Jiménez, V., Estupiñán-Bohorquez, A. F., & Acosta-Reyes, J. (2026) · BMJ Open · doi:10.1136/bmjopen-2025-105136
Romero, H. H. M., Loaiza, R. C. B., & Cambizaca, R. P. D. (2026) · Ibero Ciencias - Revista Científica y Académica · doi:10.63371/ic.v5.n1.a788
Cancer risk in patients with recurrent or persistent symptoms: a systematic review
Dannhauser, F. C., Calanzani, N., Aslam, A., Chang, A., Vimarkant, A., Majeed, M., Walter, F. M., & Zhou, Y. (2026) · The Lancet Regional Health - Europe · doi:10.1016/j.lanepe.2026.101638
“We used the Quality Assessment of Diagnostic Accuracy Studies (QUADAS-2) tool 15 to evaluate the risk of bias and applicability of included studies.”
Xiao, M., Zhang, L., Wang, H., Fan, X., Zhou, M., Lin, J., Zhang, L., Xia, J., Zong, Z., Sun, W., et al. (2026) · Journal of Microbiology Immunology and Infection · doi:10.1016/j.jmii.2026.03.003
Puga, T. B., Box, M. W., Perleberg, T. D., Paulter, B., O’Connor, K. P., & Riehl, J. T. (2026) · Advances in Orthopedics · doi:10.1155/aort/5518632
Commentary on: Artificial intelligence in thoracic surgery: Perspectives and challenges
Tahir, H. N., Malik, M., Javed, S., Rizvi, S. B., & Ali, Y. (2026) · Surgery in Practice and Science · doi:10.1016/j.sipas.2026.100337
Post-mortem ultrasound for detecting major fluid collections: a systematic review
Al-Juhani, A. A., Binshalhoub, A. A., Aljohani, N., Aljohani, O. O., & Alharbi, B. M. (2026) · Forensic Science Medicine and Pathology · doi:10.1007/s12024-026-01189-7
Cullum, S. J., Vara, A., González-Prieto, C., Yates, S., Rodriguez, C. R., Noel-Storr, A. H., Davis, D. H. J., & Mukadam, N. (2026) · npj Dementia · doi:10.1038/s44400-026-00064-0
Alves, L. H., Machado, G. F., Martin, G. C. D. C., Lemos, M. J., Sarquis, M., dos Santos, P. L., Armstrong, B. B. S., Barbosa, D., Sciorilli, J. V., Servidoni, A. C. P., et al. (2026) · Abdominal Radiology · doi:10.1007/s00261-026-05416-1
“Methodological quality was assessed by QUADAS-2 [12] using robvis tools [13] across the included 34 studies.”
Wang, H.-N., Huang, C.-K., Huang, Y.-E., Huang, Y.-T., Chan, S.-H., & Tseng, J. (2026) · Revista Española de Medicina Nuclear e Imagen Molecular (English Edition) · doi:10.1016/j.remnie.2026.500341
Sevak, P., Pham, G. T., Arruzza, E. S., Bhatia, A., To, M., & White, S. J. (2026) · Journal of Clinical Epidemiology · doi:10.1016/j.jclinepi.2026.112538
Huang, D., Zhao, Q., Wu, J., Zhong, H., Wang, Y., Zhou, H., Zhang, Y., Ran, F., Deng, J., & Ren, Q. (2026) · Pulmonology · doi:10.1080/25310429.2026.2638024
Núñez, E. D. C. D. L. T., Polit, F. A. S., Manzano, V. P. C., & Parra, J. L. E. (2026) · VitalyScience Revista Científica Multidisciplinaria · doi:10.56519/d11njr54
Challenges and Pitfalls in MIBG Imaging: A Systematic Review
Moghrabi, S., Abdlkadir, A. S., Ruzzeh, S., Osman, M., Bozkurt, M. F., Bashir, H., Lee, S. T., & Al‐Ibraheem, A. (2026) · Nuclear Medicine and Molecular Imaging · doi:10.1007/s13139-026-00990-0
“This tool evaluates the risk of bias and applicability across four domains: patient selection, index test, reference standard, and flow/timing [ 11].”
Congo, N. E. G., & Prieto, C. (2026) · VitalyScience Revista Científica Multidisciplinaria · doi:10.56519/zhg92162
Panda, K., Dash, D. P., Pattnaik, B., Gautam, V., & Panda, P. K. (2026) · Pediatric Gastroenterology Hepatology & Nutrition · doi:10.5223/pghn.2026.29.2.151
Investigations of Heterogeneity in Diagnostic Test Accuracy Meta-Analysis: A Methodological ReviewPreprint
Mischinger, L., Ernst, A., Haller, B., Fomenko, A., Aktuerk, Z., & Hapfelmeier, A. (2026) · arXiv (Cornell University) · doi:10.48550/arxiv.2603.10686
Nawabi, J., Eminovic, S., Desser, D., Fetscher, L., Rangus, I., Siebert, E., Wattjes, M. P., Weissflog, J. S., & Meddeb, A. (2026) · Computational and Structural Biotechnology Journal · doi:10.34133/csbj.0013 · Cited by 1
“The pre-stroke phase was the most represented, with 4 studies (Herrgårdh et al., 2022; Falanga et al., 2024; Upadrista et al., 2025; Dubs et al., 2023) focused on individualized stroke risk prediction [ 20 – 23 ].”
Systematic review: Accuracy of diagnostic methods for Clostridioides difficile infection
Salvador, B. C., Gomes, D. L., de Araujo, A. G. S., Marcelino, A. C. C. G., Rempel, C., Szpak, R., Pontes, T. A. A., Tonin, F. S., Nogueira, K. D. S., & Wiens, A. (2026) · Anaerobe · doi:10.1016/j.anaerobe.2026.103038
Ghasemi, F., Gholami, M. A., Ghasemi, N., & Garg, R. K. (2026) · BMC Emergency Medicine · doi:10.1186/s12873-026-01544-5
Kharaghani, M., Samiee, R., Shahsavand, A., Forghani, S., Moradi, M., Pirbazari, T. J., & Shahgholi, E. (2026) · Hematology · doi:10.1080/16078454.2026.2644716
Mikati, I. K. E., Ibrahimi, N., Alshorman, A., Sivakumaran, K., Senerth, E., Jabiri, R. A., AlShenaiber, L., Babatunde, I., Kostojchin, A., Krammer, L., et al. (2026) · PEDIATRICS · doi:10.1542/peds.2026-076120
Leonhard, C. (2026) · Journal of Forensic and Legal Medicine · doi:10.1016/j.jflm.2026.103114
Aladwani, F., Perelli, A., Mordi, I. R., & Khan, F. (2026) · European Heart Journal - Imaging Methods and Practice · doi:10.1093/ehjimp/qyag045 · Cited by 2
“21 The CLAIM is a checklist comprised of 42 items designed to assess AI research in medical imaging.”
He, C., Li, F., He, M., & Li, J. (2026) · Acta Oncologica · doi:10.2340/1651-226x.2026.44984
“Two reviewers (FL and MH) independently assessed the risk of bias (RoB) and clinical applicability for the studies included in the final analysis using the QUADAS-2 tool (Supplementary Appendix 3) [25].”
Comiz, T. F., Sabadin, G. R., & Bitencourt, P. E. R. (2026) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2026-0234
“Risk of bias was assessed independently by two reviewers (TFC and GS) using the Quality Assessment of Diagnostic Accuracy Studies-2 (QUADAS-2) tool [14], which evaluates four domains: patient selection, index test, reference standard, and fl ow and timing.”
CDA-AMC (2026) · Canadian Journal of Health Technologies · doi:10.51731/cjht.2026.1384
Melzer, Y. F., Erley, J., Ristow, I., Schubert, N., Campbell, G. M., Busse, B., Weisel, K. C., Adam, G., & Molwitz, I. (2026) · TumorDiagnostik & Therapie · doi:10.1055/a-2796-0120
Banik, K., Patel, J., Ibrahim, S. T., & Katapally, T. R. (2026) · Journal of Evaluation in Clinical Practice · doi:10.1111/jep.70410
Neveux, M., Hylin, R., Gonzalez, V. R., Parra, A. P. L., Onoja, A. J., Sirivichayakul, S., Sulaimon, A. A., Rwibasira, G. N., & Ochwoto, M. (2026) · medRxiv · doi:10.64898/2026.03.19.26347008
da Silva, M. O., Duarte, M. L., & da Silva, M. S. P. (2026) · Journal of Medical Imaging and Radiation Oncology · doi:10.1111/1754-9485.70087
“Because dose-optimisation studies do not include a diagnostic reference standard and therefore cannot be evaluated with QUADAS-2 tool (Quality Assessment of Diagnostic Accuracy Studies) [22], this tool was not applied in the final analysis.”
Chen, C., Hsiao, K., & Lin, H. (2026) · Cancer Cytopathology · doi:10.1002/cncy.70088
da Silva, L. P., da Silva, F. M. F., Magno, M. B., Ferreira, D. M. T. P., de Castro, A. C. R., Visconti, M. A., Maia, L. C., & Neves, A. D. A. (2026) · International Journal of Dental Hygiene · doi:10.1111/idh.70041
“The evaluation of methodological quality in the included studies was performed according to the quality assessment of diagnostic accuracy studies (QUADAS-2) [21].”
Influential
Metadata
- Authors
- Whiting, P. F., Rutjes, A. W. S., Westwood, M. E., Mallett, S., Deeks, J. J., Reitsma, J. B., Leeflang, M. M. G., Sterne, J. A. C., Bossuyt, P. M. M., & the QUADAS-2 Group*
- Affiliations
- University of Bern (CH)
- Corresponding author
- Whiting, Penny F.
- ORCID
- Venue
- Annals of Internal Medicine
- Publisher
- American College of Physicians
- Published
- 2011-10-18
- Volume
- 155
- Issue
- 8
- Pages
- 529-536
- ISSN
- 0003-4819 (ISSN-L)
- 1539-3704
- OpenAlex
- W2107638293
- Semantic Scholar
- 8a5d0b5a9271ea14bcb8479bc32d3844a80655b9
- Cited by
- 14,199
- References
- 18
- Citations by year
- 2026: 1484 · 2025: 1569 · 2024: 1524 · 2023: 1305 · 2022: 1420 · 2021: 1514 · 2020: 1245 · 2019: 955 · 2018: 767 · 2017: 637 · 2016: 580 · 2015: 528 · 2014: 363 · 2013: 217 · 2012: 75
- FWCI
- 224.36
- Type
- journal article
- Language
- en
- Open access
- green
- hdl.handle.net
- Licence
- cc-by
- www.acpjournals.org/journal/aim/text-and-data-mining (tdm)
- Locations
- Annals of Internal Medicine (publishedVersion)
- PubMed (publishedVersion)
- Pure Amsterdam UMC (publishedVersion)
- Data Archiving and Networked Services (DANS) (submittedVersion)
- Florence Research (University of Florence) (submittedVersion)
- IRIS UNIMORE (University of Modena and Reggio Emilia) (submittedVersion, cc-by)
- University of Birmingham Research Portal (University of Birmingham) (submittedVersion)
- Bristol Research (University of Bristol) (submittedVersion)
- Funders
- Cancer Research UK
- Topics
- Social Sciences › Decision Sciences › Statistics, Probability and Uncertainty › Meta-analysis and systematic reviews
- Physical Sciences › Mathematics › Statistics and Probability › Statistical Methods in Epidemiology
- Health Sciences › Medicine › Public Health, Environmental and Occupational Health › Clinical practice guidelines implementation
- Keywords
- QUADAS-2, diagnostic accuracy studies, quality assessment, risk of bias, applicability, patient selection, index tests, reference materials, flowcharts, systematic reviews
- MeSH terms
- Diagnosis, Humans, Quality Control, Surveys and Questionnaires, Reference Standards, Review Literature as Topic, Time Factors, Bias, Patient Selection, Evidence-Based Medicine
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
A language model drew the claims from the paper on 2026-11-23, under version 3 of the claim definition (model deepseek-v4.1-flash, prompt extract-v3).
A second model labelled each claim on 2026-11-23 (model jev-1.13-20260917, definition revision gold-guideline-v0.2).
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.