QUADAS-2: A Revised Tool for the Quality Assessment of Diagnostic Accuracy Studies
Open accessThe DOI matches its Crossref record; 18 of the 18 references it cites were found in a registry or an index; none of the 21 sources its claims cite is checked for support yet.
Abstract
In 2003, the QUADAS tool for systematic reviews of diagnostic accuracy studies was developed. Experience, anecdotal reports, and feedback suggested areas for improvement; therefore, QUADAS-2 was developed. This tool comprises 4 domains: patient selection, index test, reference standard, and flow and timing. Each domain is assessed in terms of risk of bias, and the first 3 domains are also assessed in terms of concerns regarding applicability. Signalling questions are included to help judge risk of bias. The QUADAS-2 tool is applied in 4 phases: summarize the review question, tailor the tool and produce review-specific guidance, construct a flow diagram for the primary study, and judge bias and applicability. This tool will allow for more transparent rating of bias and applicability of primary diagnostic accuracy studies.
Overview
CoChat Summary
TL;DR
QUADAS-2 is a revised tool for assessing risk of bias and applicability in diagnostic accuracy studies, developed through a 4-stage evidence-based consensus process. It replaces the original QUADAS “yes/no/unclear” quality rating with domain-level judgments of low, high, or unclear risk of bias and concerns about applicability.
Key findings
- QUADAS-2 separates “quality” into risk of bias and concerns regarding applicability, defining quality as the degree to which diagnostic accuracy estimates avoided bias and the extent to which primary studies are applicable to the review question.
- The tool has 4 key domains—patient selection, index test, reference standard, and flow and timing—with the first 3 also assessed for applicability; it is completed in 4 phases and uses signaling questions to help judge risk of bias.
- Development drew on 4 reviews: 54 diagnostic accuracy reviews published between 2007 and 2009, structured feedback from 64 systematic reviewers who had used QUADAS, 101 studies on sources of bias and variation, and 8 studies evaluating QUADAS; a 1-day consensus meeting had 24 attendees, and piloting occurred in 5 reviews.
- Interrater reliability varied considerably, with better agreement on applicability than on risk of bias; all participants preferred QUADAS-2 to the original tool, but the authors could not currently include criteria for studies comparing multiple index tests because the evidence base was insufficient.
Methods
- Tool development followed Moher and colleagues’ 4-stage approach: define the scope, review the evidence base, hold a face-to-face consensus meeting, and refine through piloting.
- A steering group of 9 experts set the scope; the consensus meeting was held on 21 September 2010 in Birmingham, United Kingdom, with 24 attendees who split into groups of 4 to 6 participants; multiple rounds of piloting used online questionnaires and other feedback, including pairs of reviewers piloting QUADAS-2 in 5 reviews.
- No primary statistical analysis was reported; the work synthesized evidence reviews, consensus decisions, and pilot feedback to produce and refine the tool.
Limitations
- Stated: the authors decided they cannot currently include criteria for assessing studies that compare multiple index tests within QUADAS-2 because of the limited evidence base on risk of bias and sources of variation in such studies, and they plan future work on this topic.
- Stated: piloting showed poor interrater reliability and problems applying the domain on comparative accuracy studies; interrater reliability varied considerably overall, with better agreement on applicability than on risk of bias.
- Evident from the text: full details of the 4 evidence reviews were to be published separately, and the main text reports no quantitative reliability estimates, referring instead to an Appendix Table.
Model-written summary. Check it against the paper before relying on it.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
0 Valid · 0 Not valid · 16 Not checked · 24 Own results and interpretations
In the paper
“In a review on anti-cyclic citrullinated peptide antibodies for diagnosing rheumatoid arthritis (10), we found that some studies enrolled consecutive participants with confirmed diagnoses. In these studies, testing for anticyclic citrullinated peptide antibody showed greater sensitivity than in studies that included patients with suspected disease but an unconfirmed diagnosis (that is, difficult-t”
§ QUADAS-2: A Revised Tool for the Quality Assessment of Diagnostic Accuracy Studies > Signaling question 2: Was a case-control design avoided? Signaling question 3: Did the study avoid inappropriate exclusions?
What the sources say
- Not matchedcites [10]
The reference list we hold has no entry [10].
plainstates an association- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Not matched
A statement the paper makes itself — it cites no source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“Studies that make inappropriate exclusions (for example, not including”
§ QUADAS-2: A Revised Tool for the Quality Assessment of Diagnostic Accuracy Studies > Signaling question 2: Was a case-control design avoided? Signaling question 3: Did the study avoid inappropriate exclusions?
hedgedstates a possible cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
None of the sources cited for this claim could be matched to a paper, so there is nothing to check it against.
In the paper
“Because the accuracy of a test may depend on where it will be used in the diagnostic pathway, review authors are asked to describe patients in terms of setting, intended use of the index test, patient presentation, and previous testing (8,9).”
§ QUADAS-2: A Revised Tool for the Quality Assessment of Diagnostic Accuracy Studies > Phase 1: Review Question
What the sources say
- Not matchedcites [8]
The reference list we hold has no entry [8].
- Not matchedcites [9]
The reference list we hold has no entry [9].
hedgedstates a possible cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Not matched
In the paper
“Development of QUADAS-2 was based on the 4-stage approach proposed by Moher and colleagues (4): define the scope, review the evidence base, hold a face-to-face consensus meeting, and refine the tool through piloting.”
§ QUADAS-2: A Revised Tool for the Quality Assessment of Diagnostic Accuracy Studies > METHODS
What the sources say
- Not matchedcites [4]
The reference list we hold has no entry [4].
plainstates a cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: unclear — It is unclear whether the paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Not matched
None of the sources cited for this claim could be matched to a paper, so there is nothing to check it against.
In the paper
“Studies enrolling participants with known disease and a control group without the condition may similarly exaggerate diagnostic accuracy (7,11).”
§ QUADAS-2: A Revised Tool for the Quality Assessment of Diagnostic Accuracy Studies > Signaling question 2: Was a case-control design avoided? Signaling question 3: Did the study avoid inappropriate exclusions?
What the sources say
- Not matchedcites [7]
The reference list we hold has no entry [7].
- Not matchedcites [11]
The reference list we hold has no entry [11].
hedgedstates a possible cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Not matched
10 more claims
Create a free account to see all 40 claims and every source verdict.
- Probably not a substantial claim. 19
- It may state two separate claims as one. 16
- The quote only partly states this claim. 2
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“We assessed the study-level risk of bias with the QUADAS-2 tool”
In the citing paper
“We developed a revised risk-of-bias assessment tool to address these issues, incorporate advances in assessment of risk of bias used in other recently developed tools, 9 10 and integrate recent developments in estimation of intervention effects from randomised trials. 11”
From RoB 2: a revised tool for assessing risk of bias in randomised trials (2019) · cites this paper as [10]
In the citing paper
“Two reviewers independently assessed the quality of the included studies with the Quality Assessment of Diagnostic Accuracy Studies (Quadas-2) [33].”
From High-standard predictive equations for estimating body composition using bioelectrical impedance analysis: a systematic review (2024) · cites this paper as [33]
In the citing paper
“The quality of the selected studies was rigorously assessed using the Checklist for Artificial Intelligence in Medical Imaging (CLAIM) alongside the Quality Assessment of Diagnostic Accuracy Studies-2 (QUADAS-2).23,24”
From Artificial Intelligence Detection and Segmentation Models: A Systematic Review and Meta-Analysis of Brain Tumors in Magnetic Resonance Imaging (2024) · cites this paper as [24]
In the citing paper
“The methodological quality of each selected study was assessed according to the Quality Assessment of Diagnostic Accuracy Studies (QUADAS-2) checklist [15]”
From The diagnostic accuracy of digital, infrared and mercury-in-glass thermometers in measuring body temperature: a systematic review and network meta-analysis (2021) · cites this paper as [15]
20 more claims about this paper
Create a free account to see every claim other papers make about this one.
Citations
Cites
The Cochrane Collaboration's tool for assessing risk of bias in randomised trials
Higgins, J. P. T., Altman, D. G., Gotzsche, P. C., Juni, P., Moher, D., Oxman, A. D., Savovic, J., Schulz, K. F., Weeks, L., Sterne, J. A. C., et al. (2011) · BMJ · doi:10.1136/bmj.d5928 · Cited by 33,817
Self-citationWhiting, P., Rutjes, A. W., Reitsma, J. B., Bossuyt, P. M., & Kleijnen, J. (2003) · BMC Medical Research Methodology · doi:10.1186/1471-2288-3-25 · Cited by 3,592
Self-citationThe Hazards of Scoring the Quality of Clinical Trials for Meta-analysis
Jüni, P. (1999) · JAMA · doi:10.1001/jama.282.11.1054 · Cited by 1,981
Empirical evidence of design-related bias in studies of diagnostic tests.
Lijmer, J. G. (1999) · JAMA · doi:10.1001/jama.282.11.1061 · Cited by 1,861 · cited 2×
“Studies enrolling participants with known disease and a control group without the condition may similarly exaggerate diagnostic accuracy (7, 11).”
BackgroundGuidance for Developers of Health Research Reporting Guidelines
Moher, D., Schulz, K. F., Simera, I., & Altman, D. G. (2010) · PLoS Medicine · doi:10.1371/journal.pmed.1000217 · Cited by 1,437
Systematic Reviews of Diagnostic Test Accuracy
Leeflang, M. M. G., Deeks, J. J., Gatsonis, C., & Bossuyt, P. M. M. (2008) · Annals of Internal Medicine · doi:10.7326/0003-4819-149-12-200812160-00008 · Cited by 1,124
Self-citationSources of Variation and Bias in Studies of Diagnostic Accuracy: A Systematic Review
Whiting, P., Rutjes, A. W. S., Reitsma, J. B., Glas, A. S., Bossuyt, P. M. M., & Kleijnen, J. (2004) · Annals of Internal Medicine · doi:10.7326/0003-4819-140-3-200402030-00010 · Cited by 798 · cited 4×
“The third review was an update on sources of bias and variation in diagnostic accuracy studies that included 101 studies (7).”
BackgroundInfluentialSelf-citationEvaluation of QUADAS, a tool for the quality assessment of diagnostic accuracy studies
Whiting, P. F., Weswood, M. E., Rutjes, A. W., Reitsma, J. B., Bossuyt, P. N., & Kleijnen, J. (2006) · BMC Medical Research Methodology · doi:10.1186/1471-2288-6-9 · Cited by 769
Self-citationLeeflang, M. M. G., Moons, K. G. M., Reitsma, J. B., & Zwinderman, A. H. (2008) · Clinical Chemistry · doi:10.1373/clinchem.2007.096032 · Cited by 346 · cited 1×
“Test performance is likely to be poorer in an independent sample of patients in whom the same threshold is used (12).”
BackgroundSelf-citationNo role for quality scores in systematic reviews of diagnostic accuracy studies
Whiting, P., Harbord, R., & Kleijnen, J. (2005) · BMC Medical Research Methodology · doi:10.1186/1471-2288-5-19 · Cited by 337
Self-citation
Cited by
Items 13,601–13,700 of 14,770
Diagnostic accuracy of physical examination for the assessment of popliteal cysts: a meta-analysis
Tang, L., Liu, M., Sheng, B., Hu, L., Li, Q., & Cai, H. (2026) · Frontiers in Medicine · doi:10.3389/fmed.2026.1797462
Song, Y., Weng, D., Chen, Y., & Wenren, Y. (2026) · International Journal of Gynecological Cancer · doi:10.1016/j.ijgc.2026.104667
Lin, J., Ji, Z., Wu, L., Bao, Z., Dai, Y., Lin, X. C., Yan, Y., Chen, Y., Pang, X., Ye, J., et al. (2026) · Systematic Reviews · doi:10.1186/s13643-026-03160-7
“Eligible trials were appraised using the QUADAS-2 checklist across four domains: patient selection, index test, reference standard, and flow/timing [24].”
Takács, A., Tábi, D., Cavalcante, B. G. N., Szabó, B., Wenning, A. S., Gerber, G., Hermann, P., Varga, G., Hegyi, P., & Kivovics, M. (2026) · Journal of Clinical Medicine · doi:10.3390/jcm15062447
“All domains for risk of bias, as well as the first three for applicability concerns, could be described as “low,” “unclear,” or “high” [13].”
Verma, K., & Kumar, S. (2026) · Journal of Alzheimer s Disease · doi:10.1177/13872877261430858
Wang, Y., Liu, X., & Zhenwen, X. I. A. O. (2026) · Frontiers in Endocrinology · doi:10.3389/fendo.2026.1811189 · Cited by 1
MacLean, J. E., Adeleye, A., Dam, A. V., Lal, A., Abusido, T. A., Adamko, D. J., Amin, R., Campisi, P., Constantin, E., Duncan, J., et al. (2026) · Canadian Journal of Respiratory Critical Care and Sleep Medicine · doi:10.1080/24745332.2026.2629327
“19,20 The assessment of children with suspected OSA can be challenging because of a wide spectrum of risk factors, presentations, and consequences.”
Ni, Y., Stevens, S. M., House, T., Steed, A. H., Jukic, A., Hareesh, P., Asher, A. M., Almefty, K. K., Smith, K. A., Porter, R. W., et al. (2026) · Journal of Neuroimaging · doi:10.1111/jon.70131
“Bias analysis was performed using the QUADAS-2 protocol [ 22 ] by two authors.”
Alharazy, S. M., Azzani, M., Shirin, L., Kabir, M. S., Abdulhameed, T. H., Anbazhagan, D., & Islam, T. (2026) · Clinica Chimica Acta · doi:10.1016/j.cca.2026.120977 · Cited by 1
Boers, N., Hahn, B. A., Eligh, A. M., Jongen, I. C., Rinkel, W. D., & Coert, J. H. (2026) · Diabetes Research and Clinical Practice · doi:10.1016/j.diabres.2026.113226
Xuto, P., Khiaokham, L., Bressington, D. T., & Khaw-on, P. (2026) · Nursing Reports · doi:10.3390/nursrep16040107
de Lima, V. C. C., Baldotto, C. S. D. R., Mascarenhas, E., Gelatti, A. C. Z., Mathias, C., de Araújo, L. H. L., Zukin, M., Prado, G. F., & Castro, G. (2026) · JCO Global Oncology · doi:10.1200/go-25-00066
Efficacy of swab-based RUT in detecting H. pylori infection: a systematic review and meta-analysis
Awad, A. A., Aldemerdash, M. A., El-Khalifa, B. M., Emara, A. M., Othman, A. M., Balouz, M. A., Narouz, Y., Elmarzouky, D. A., Albawri, A. A., Harash, Y. M., et al. (2026) · BMC Gastroenterology · doi:10.1186/s12876-025-04576-6
“Each domain is thoroughly evaluated for risk of bias and applicability [14].”
Bächle, C., Stoye, F. V., Mashhadi, N. S., Klötzsch, A., Bongaerts, B. W. C., Hoyer, A., Kuss, O., Landgraf, R., Rathmann, W., & Schlesinger, S. (2026) · Diabetes/Metabolism Research and Reviews · doi:10.1002/dmrr.70160
“The risk of bias of the included studies was independently assessed by two reviewers (CB, NS) using the validated Quality Assessment of Diagnostic Accuracy Studies (QUADAS‐2) tool [33] (additional details are given in the Supporting Information S1: Appendix 3).”
Chuang, W.-K., Lin, B., Lee, Y., Su, P.-H., Kao, Y., & Lu, C.-F. (2026) · Archives of Physical Medicine and Rehabilitation · doi:10.1016/j.apmr.2026.03.016
Lind, A. N. R., Kristensen, M. H., Hvingelby, V. S., Rasmussen, M. J. K., Koch, K. U., Granfeldt, A., Mikkelsen, R., Rasmussen, L. K., Simonsen, C. Z., Gude, M. F., et al. (2026) · Journal of Neurotrauma · doi:10.1177/08977151261436289
Taher, H. J., Baharishargh, R., Sharifian, F., Rad, F. N., Mirhosseini, S., Sharifpour, S., Yarahmadi, D., & Alizadeh, Z. (2026) · Clinical and Experimental Medicine · doi:10.1007/s10238-026-02087-6
“Risk of bias and applicability concerns were assessed using QUADAS-2 across four domains (patient selection, index test, reference standard, and flow/timing) and the first three domains for applicability [ 15].”
Kikkawa, K., Yokoyama, S., Kanai, R., Maruno, K., Nakayasu, R., Takahashi, T., Yamada, Y., Nakashima, M., Tamaki, M., & Ito, N. (2026) · Journal of Pediatric Urology · doi:10.1016/j.jpurol.2026.105915
Kuas, Ç., & Kuas, N. (2026) · Journal of Pediatric Urology · doi:10.1016/j.jpurol.2026.105914
Kang, E., Cha, J. M., Kang, S. Y., Lee, K., Kim, S. Y., Kim, Y.-H., Seo, A. N., Kang, H.-J., Jang, J. K., Ko, K., et al. (2026) · Journal of Korean Medical Association · doi:10.5124/jkma.26.0002
Deep Brain Stimulation for Psychiatric Disorders: A Systematic Review of Molecular Imaging with PET
Patil, S., Gerlach, A. D. M., Jeevika, F., Patel, R. K. P., Christner, E., Gujral, J., Gandhi, O. H., Writer, M., Wang, N. M., Kopylova, A., et al. (2026) · World Neurosurgery · doi:10.1016/j.wneu.2026.124933
Shao, M. M., Scheideman, A. F., Zhou, A. M., Kohn, M. A., DiMeglio, L. A., Quandt, Z., Speake, C., Ho, C., & Klonoff, D. C. (2026) · Frontiers in Endocrinology · doi:10.3389/fendo.2026.1771950
Bloedbiomarkers voor de ziekte van Alzheimer: de klinische waarde op de geheugenpoli
Kloppenburg-Lagendijk, M., Huitema, Y. M., van Harten, A. C., Hempenius, L., & Verwey, N. A. (2026) · Tijdschrift voor Gerontologie en Geriatrie · doi:10.54195/tgg24597
Hajikarimloo, B., Mohammadzadeh, I., Tos, S. M., Bahri, A., Sabaghian, A., & Habibi, M. A. (2026) · Endocrine · doi:10.1007/s12020-026-04590-y
Mavi, R. (2026) · Balkan Journal of Dental Medicine · doi:10.5937/bjdm2601010s
Cénac, I. (2015) · theses.fr (ABES) · doi:10.70675/b715fb95zb147z456czb4e5zcbb7e0497388
Morales, A. Q. V., Balderas, Y. O., Oliver, A., García, A. J. F., Mendoza, V. M. P., Correa, E. J. L., & Perez, I. P. G. (2026) · Cureus · doi:10.7759/cureus.106223
“The Quality Assessment of Diagnostic Accuracy Studies-2 (QUADAS-2) tool [16], which is specifically designed to evaluate the risk of bias and applicability of primary diagnostic accuracy studies, was used, modified for the review question, to assess risk of bias in individual studies.”
Gayet‐Ageron, A. (2015) · theses.fr (ABES) · doi:10.70675/f831e32dzf406z4ae4za84ez2f947fe3ab2e
Hazewinkel, A., Curnow, E., Tilling, K. M., & Hughes, R. A. (2026) · BMC Medical Research Methodology · doi:10.21203/rs.3.rs-9283156/v1
Nakade, M., Shettar, V., & Jirge, V. L. (2025) · BULLETIN OF STOMATOLOGY AND MAXILLOFACIAL SURGERY · doi:10.58240/1829006x-2025.21.12-436
Multimarkers approach in emergency medicine
Freund, Y. (2015) · theses.fr (ABES) · doi:10.70675/32914bf4zfb57z4185zbd2dz38d8ab25389a · Cited by 1
Forouzannia, S. A., Fathi, M., Tran, C., Vafaei, S. M., Bahrami, A., Abdulla, J., & Umair, M. (2026) · Research Square · doi:10.21203/rs.3.rs-8981414/v1
Délais diagnostiques des cancers de l’enfant : distribution, déterminants et conséquences
Brasme, J. (2014) · theses.fr (ABES) · doi:10.70675/7441aad1z9e59z494bz8310zc706f7fe7128
Shortcomings in and preferred strategies for evaluating biomarkers as medical tests
Olsen, M. (2021) · theses.fr (ABES) · doi:10.70675/535e1627z1a35z437cz8c94z8701a5d0d2b7
Hajalamin, M., Msherghi, A. A. A., Alhammadi, I., Sultan, A., Alatefi, D., Wahhab, A., Hijeh, S., Alsharif, M., Khalid, S., Shembesh, R. H., et al. (2026) · European Journal of Radiology · doi:10.1016/j.ejrad.2026.112836
Krishnan, N., Kainth, D., Agarwala, S., Garriboli, M., Kandasamy, D., Verma, P., Agarwala, S., & Anand, S. (2026) · Journal of Pediatric Urology · doi:10.1016/j.jpurol.2026.105930
Guingané, N. A. (2021) · theses.fr (ABES) · doi:10.70675/46b97ab0zf55dz4723z8de3z1c2d625ea853
La santé publique comme nouvelle approche clinique de dépistage et de diagnostic du cancer oral
Lan, R. (2021) · theses.fr (ABES) · doi:10.70675/4ddb3800z1c27z48dbza352zadb4fd1346fa · Cited by 1
Domínguez-Rojas, J., Torres, S., Aceituno, A. M., Arias, A. V., Sequeria, G., Tatay, D., Robles, L. N. M., Muñoz, C. M., & Llano, L. (2026) · Critical Care Research and Practice · doi:10.1155/ccrp/1818873
Bhosale, A. S., Verdugo‐Paiva, F., Urquhart, O., Martins-Pfeifer, C. C., Weinstein, M. W., Walsh, T., O’Brien, K. K., Rojas-Gómez, A. M., Glick, M., Lingen, M. W., et al. (2026) · The Journal of the American Dental Association · doi:10.1016/j.adaj.2026.01.008 · Cited by 2
Instrucciones para los autores y revisores
(2024) · Archivos de Medicina (Manizales) · doi:10.30554/archmed.24.1.5110.2024
Kamath, A. G., Gill, S. S., Shinwari, H., & Sugand, K. (2026) · EFORT Open Reviews · doi:10.1530/eor-2024-0165
Anusikha, A., Chinnannavar, S. N., Mishra, S., Bajoria, A. A., Pathi, J., & Nahar, N. (2026) · Asian Pacific Journal of Cancer Prevention · doi:10.31557/apjcp.2026.27.4.1189
“To assess methodological quality, we used the quality assessment of diagnostic accuracy studies - 2 (QUADAS-2) tool [17], evaluating several domains like patient selection, index test, reference standard, and timing and flow of patients.”
Promoting safe use of medicines in hospitalised children
Arab, R. (2022) · theses.fr (ABES) · doi:10.70675/f1bfa66az77dbz4e2ezae46z1f88ed3fa57d
Alsabri, M., Abady, E. M. A., Elsnhory, A. B., Aboali, A. A., & Rath, S. (2026) · International Journal of Emergency Medicine · doi:10.1186/s12245-026-01198-x
“Risk of bias was assessed using the QUADAS-2 tool across four domains: patient selection, index test, reference standard, and flow/timing [25].”
Diagnostic Accuracy of the Autism-Spectrum Quotient: A Brief Systematic Review and Meta-Analysis
Wilson, A. C. (2026) · Review Journal of Autism and Developmental Disorders · doi:10.1007/s40489-026-00604-7
Intérêt des biomarqueurs cérébraux dans la prise en charge du traumatisme crânien
Oris, C. (2021) · theses.fr (ABES) · doi:10.70675/67e4562az92fbz47b9z9a68zc756ddc18c90
Apprentissage et modélisation statistique en médecine du sommeil : du diagnostic au traitement
Bertelli, F. (2023) · theses.fr (ABES) · doi:10.70675/1ac7521az0ed1z4fb1z8a91z8a56b70a7206
Valle, F. G., León, P. R. P., & Oblitas, C. (2026) · Heart Failure Clinics · doi:10.1016/j.hfc.2026.02.005
Contribution des études observationnelles dans la méta-analyse
Cheurfa, C. (2023) · theses.fr (ABES) · doi:10.70675/ecaa782bz76f7z4c43za043ze1d3e0cfbfaa
Verma, V., Gupta, S., Singh, P., & Karkhur, S. (2026) · Cureus · doi:10.7759/cureus.106722
Hassan, A. A. A., Khalifa, A. A., Villalón, A. R., Hauri, D. D., & Zhu, T. Y. (2026) · World Journal of Orthopedics · doi:10.5312/wjo.v17.i4.116076
Liu, X., & Lei, J. (2026) · Clinical & Translational Oncology · doi:10.1007/s12094-026-04346-0
“Two researchers independently assessed the methodological quality of the included studies using the Quality Assessment of Diagnostic Accuracy Studies-2 (QUADAS-2) tool [14] and the Radiomics Quality Score (RQS) [15].”
Wang, X.-C., Liu, J.-H., Zhang, X.-H., Liu, M., Dan-Dan, X., & Liu, W. (2026) · Chinese Journal of Analytical Chemistry · doi:10.1016/j.cjac.2026.100732
Gatta, E., Ugoccioni, M., Gandossi, E., Delbarba, A., Agosti, B., Pirola, I., Rotondi, M., & Cappelli, C. (2026) · Endocrine Practice · doi:10.1016/j.eprac.2026.04.002
Contrast-Enhanced Mammography in the Work-up of Asymmetries: A Systematic Review and Meta-analysis
Ferré, R., Benefield, T., & Kuzmiak, C. M. (2026) · Academic Radiology · doi:10.1016/j.acra.2026.03.028 · Cited by 3
Szpinda, Ł., Lis, M., Pruc, M., Kotfis, K., Katipoglu, B., Çolak, Ş., Gromek, K., Umińska, J. M., Kubica, J., & Szarpak, P. L. (2026) · Medical Research Journal · doi:10.5603/mrj.109081
Trabelsi, I., Diop, S., Jouen, F., & Bergounioux, J. (2026) · IEEE Computational Intelligence Magazine · doi:10.1109/mci.2026.3656251
“Diagnostic accuracy studies were assessed using the Quality Assessment of Diagnostic Accuracy Studies 2 (QUADAS-2) tool [11], which evaluates risk of bias across patient selection, index test, reference standard, and fl ow and timing domains.”
Behbehani, A. A., Al-Awadhi, M. A., Al-Shammari, Y. M., Albusairi, S. T., Rouhaldeen, S. Y., Alsheeha, A. N., Alkhalfan, D. A., & Salem, S. M. (2026) · Urolithiasis · doi:10.1007/s00240-026-01974-7
Diagnostic Accuracy of the Archimedes Spiral Test for Essential Tremor: A Meta-Analysis
Macêdo, V. F. B., Lang, M., & Coelho, J. A. P. D. M. (2026) · Tremor and Other Hyperkinetic Movements · doi:10.5334/tohm.1151
Calderone, A., Luca, R. D., Corallo, F., Marra, A., Arcadi, F. A., Casella, C., Quartarone, A., & Calabrò, R. S. (2026) · Journal of Translational Medicine · doi:10.1186/s12967-026-08106-0
“Methodological appraisal tools for diagnostic accuracy are also relevant when studies aim to classify PSCI or depression phenotypes, because bias in patient selection, index test conduct, and reference standards can inflate performance estimates [153].”
Lu, Y., Xu, C., He, J., Zhang, H., & Zhang, L. (2026) · Journal of Investigative Medicine · doi:10.1177/10815589261444736
Dasgupta, I., Dasgupta, B., & Chowdhury, O. R. (2026) · International Journal of Advanced Research · doi:10.21474/ijar01/23007
Kimber, T. B., Hunter, D. J., Akam, E. C., Singh, M., Singh, P., & Mastana, S. S. (2026) · International Journal of Molecular Sciences · doi:10.3390/ijms27219827
Correlation Between Epicardial Adipose Tissue and PET Cardiac Perfusion: A Systematic Review
Dondi, F., Bellini, P., Bertoli, M., Viganò, G. L., Rinaldi, R., Camoni, L., Cossandi, M., Vizzardi, E., Lombardi, C. M., & Bertagna, F. (2026) · Medical Sciences · doi:10.3390/medsci14020194
“The quality assessment of these studies, including the risk of bias and applicability concerns, was carried out using the Quality Assessment of Diagnostic Accuracy Studies version 2 (QUADAS-2) evaluation [21].”
David, G. B., Ramos, N., Huntermann, R., de Oliveira, J. P., Molinari, M. E., & Bacca, C. D. O. F. (2026) · International Journal of Cardiovascular Sciences · doi:10.36660/ijcs.20250091
Shuborna, N. S., Mattheos, N., Jiaranuchart, S., Changsiripun, C., & Subbalekha, K. (2026) · Journal of Prosthetic Dentistry · doi:10.1016/j.prosdent.2026.03.036
Altunhan, A., Tekeli, R., Ortner, G., Güldibi, F., Ahmed, K., Somani, B. K., Güven, S., & Tokas, T. (2026) · Arab Journal of Urology · doi:10.1080/20905998.2026.2657150
Use of Artificial Intelligence in the Interpretation of Electroretinography (ERG) Studies
Hegde, M., Thomis, A., & Shirke, S. (2026) · International Journal of Molecular Sciences · doi:10.3390/ijms27083491
“[10,11,24–35] using QUADAS-2 tool [18].”
Fu, H., Liu, H., Han, Y., Wang, T., Yu, J., Liu, W., Liu, Z., Hu, X., Shen, Z., & Gao, Y. (2026) · Frontiers in Endocrinology · doi:10.3389/fendo.2026.1814762
Macierzanka, K., Chatterjee, A., Adnan, A., Marzook, H., Yousaf, R., Laurence, C., & Gavela, J. (2026) · Echocardiography · doi:10.1111/echo.70443
“Study quality was independently assessed by three investigators (A.A., H.M., and R.Y.) using the Quality Assessment of Diagnostic Accuracy Studies 2 (QUADAS-2) risk of bias tool [ 24 ].”
Validity of Glucose Measurement Methods During Surgery: A Systematic Review
Heatlie, L. C., Ejaredar, M., Lithgow, K. C., Dillane, D., Manek, R., Gill, S., Cameron, A. T., Füzéry, A. K., Pham, M. M., Subramanian, A., et al. (2026) · Canadian Journal of Diabetes · doi:10.1016/j.jcjd.2026.04.002
Wang, J., Lin, H.-A., Huang, H.-C., Lin, Y., & Lin, S. (2026) · Emergency Medicine Journal · doi:10.1136/emermed-2025-215449
Snell, L. B., Batra, R., Breuer, J., Brown, J. R., Edgeworth, J. D., Gant, V. A., Gouliouris, T., Grant, P. R., Green, S. M., Hammond, R., et al. (2026) · Communications Medicine · doi:10.1038/s43856-026-01968-x
de Abreu, B. F. B. B., Scarmagnan, G. S., Duarte, M. L., da Silva, M. O., & Iared, W. (2026) · Sao Paulo Medical Journal · doi:10.1590/1516-3180.2025.3088.11112025
Kalinoski, T., Kalinoski, M., Kline, S., Brearley, A. M., Nigam, A., & Harmon, J. V. (2026) · Open Forum Infectious Diseases · doi:10.1093/ofid/ofag221
“Methodological quality was independently assessed by 2 re-viewers using the Quality Assessment of Diagnostic Accuracy Studies 2 (QUADAS-2) tool [19].”
Putra, A. D., Rahman, A. T., Syariatin, L., Darmawan, N. S., Cuandra, K. N., Hamka, M. F., Setiya, D. F. J., Argani, A. N., Aaliyya, Z. S., Widi, V. S. N., et al. (2026) · F1000Research · doi:10.12688/f1000research.179155.1
Ge, L., Hu, Y., Gao, B., Wang, S., Hou, Y., Yang, H., Wang, P., & Jiang, S. (2026) · Dysphagia · doi:10.1007/s00455-026-10928-5
“The included studies were appraised using the Quality Assessment of Diagnostic Accuracy Studies 2 (QUA-DAS-2) tool endorsed by the Cochrane Collaboration [9], which consists of 3 grades and 14 items (excluding the 3 non-essential items suggested by Cochrane).”
Wang, X., Li, T., Wang, X., & Fu, D. (2026) · Journal of Medical Internet Research · doi:10.2196/77593 · Cited by 1
“The risk of bias (RoB) of the included studies was assessed using the Quality Assessment of Diagnostic Accuracy Studies [17].”
Al-Hakami, H. A., Abdullah, I. A., Almutairi, N. S., Aldawsari, R. R., Alluqmani, G. A., Fallatah, H. A., Alsulami, Y. S., Alasiri, E. M., Alsufyani, R. D., Alorabi, R. A., et al. (2026) · Cancers · doi:10.3390/cancers18081257 · Cited by 1
Delisle, T., Cyr-Bousquet, É., Lemay, C., Ouellet, L., Desjardins-Lecavalier, C., Raynard, E. P., Morin, C., Bertrand-Bureau, C., Adadja, J., & Berthelot, S. (2026) · International Journal of Emergency Medicine · doi:10.1186/s12245-026-01228-8
“Unlike general quality assessment tools (Newcastle-Ottawa Scale for observational studies, Cochrane RoB 2 for randomized trials), QUADAS-2 addresses verification bias, threshold effects, and blinding of test interpretation [10].”
Protocol for Development of an Evidence-Based Rapid Readiness Screen
Oczkowski, S. J. W., Bayuk, T. J., Basmaji, J., Dengler, B. A., McCrea, M., Sharif, S., Stout, K., Hawryluk, G. W. J., Mangat, H. S., & Ghajar, J. (2026) · Neurosurgery Open · doi:10.1227/neuprac.0000000000000225 · Cited by 1
“14 The methodology team will use a modi fi ed GRADE approach to assess the certainty of evidence for each outcome, as each PICO is considering a screening test for inclusion within a multimodal screening algorithm, rather than as a test for direct clinical application.”
Bilé-Silva, A., Özalevli, M., Chan, G., Ahmed, S., & Tandoğdu, Z. (2026) · Precision Oncology · doi:10.3390/precisoncol1020008
Pahlevan‐Fallahy, M., Behrouzieh, S., Kian, N., Shaker, F., & Harrison, A. (2026) · Revista Brasileira de Reumatologia · doi:10.1186/s42358-026-00543-1
“In cases of conflict, a third author was consulted [33].”
Filis, P., & Foukakis, T. (2026) · European Journal of Cancer · doi:10.1016/j.ejca.2026.116747
Aran, Ö., Kılınç, D., Işık, H., Eyison, R. K., & Genç, O. (2026) · Research Square · doi:10.21203/rs.3.rs-9424193/v1
Panda, K., Dash, D. P., Pati, G. K., Maria, A., & Gautam, V. (2026) · World Journal of Hepatology · doi:10.4254/wjh.v18.i4.118038
Metadata
- Authors
- Whiting, P. F., Rutjes, A. W. S., Westwood, M. E., Mallett, S., Deeks, J. J., Reitsma, J. B., Leeflang, M. M. G., Sterne, J. A. C., Bossuyt, P. M. M., & the QUADAS-2 Group*
- Affiliations
- University of Bern (CH)
- Corresponding author
- Whiting, Penny F.
- ORCID
- Venue
- Annals of Internal Medicine
- Publisher
- American College of Physicians
- Published
- 2011-10-18
- Volume
- 155
- Issue
- 8
- Pages
- 529-536
- ISSN
- 0003-4819 (ISSN-L)
- 1539-3704
- OpenAlex
- W2107638293
- Semantic Scholar
- 8a5d0b5a9271ea14bcb8479bc32d3844a80655b9
- Cited by
- 14,199
- References
- 18
- Citations by year
- 2026: 1484 · 2025: 1569 · 2024: 1524 · 2023: 1305 · 2022: 1420 · 2021: 1514 · 2020: 1245 · 2019: 955 · 2018: 767 · 2017: 637 · 2016: 580 · 2015: 528 · 2014: 363 · 2013: 217 · 2012: 75
- FWCI
- 224.36
- Type
- journal article
- Language
- en
- Open access
- green
- hdl.handle.net
- Licence
- cc-by
- www.acpjournals.org/journal/aim/text-and-data-mining (tdm)
- Locations
- Annals of Internal Medicine (publishedVersion)
- PubMed (publishedVersion)
- Pure Amsterdam UMC (publishedVersion)
- Data Archiving and Networked Services (DANS) (submittedVersion)
- Florence Research (University of Florence) (submittedVersion)
- IRIS UNIMORE (University of Modena and Reggio Emilia) (submittedVersion, cc-by)
- University of Birmingham Research Portal (University of Birmingham) (submittedVersion)
- Bristol Research (University of Bristol) (submittedVersion)
- Funders
- Cancer Research UK
- Topics
- Social Sciences › Decision Sciences › Statistics, Probability and Uncertainty › Meta-analysis and systematic reviews
- Physical Sciences › Mathematics › Statistics and Probability › Statistical Methods in Epidemiology
- Health Sciences › Medicine › Public Health, Environmental and Occupational Health › Clinical practice guidelines implementation
- Keywords
- QUADAS-2, diagnostic accuracy studies, quality assessment, risk of bias, applicability, patient selection, index tests, reference materials, flowcharts, systematic reviews
- MeSH terms
- Diagnosis, Humans, Quality Control, Surveys and Questionnaires, Reference Standards, Review Literature as Topic, Time Factors, Bias, Patient Selection, Evidence-Based Medicine
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
A language model drew the claims from the paper on 2026-11-23, under version 3 of the claim definition (model deepseek-v4.1-flash, prompt extract-v3).
A second model labelled each claim on 2026-11-23 (model jev-1.13-20260917, definition revision gold-guideline-v0.2).
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.