QUADAS-2: A Revised Tool for the Quality Assessment of Diagnostic Accuracy Studies
Open accessThe DOI matches its Crossref record; 18 of the 18 references it cites were found in a registry or an index; none of the 21 sources its claims cite is checked for support yet.
Abstract
In 2003, the QUADAS tool for systematic reviews of diagnostic accuracy studies was developed. Experience, anecdotal reports, and feedback suggested areas for improvement; therefore, QUADAS-2 was developed. This tool comprises 4 domains: patient selection, index test, reference standard, and flow and timing. Each domain is assessed in terms of risk of bias, and the first 3 domains are also assessed in terms of concerns regarding applicability. Signalling questions are included to help judge risk of bias. The QUADAS-2 tool is applied in 4 phases: summarize the review question, tailor the tool and produce review-specific guidance, construct a flow diagram for the primary study, and judge bias and applicability. This tool will allow for more transparent rating of bias and applicability of primary diagnostic accuracy studies.
Overview
CoChat Summary
TL;DR
QUADAS-2 is a revised tool for assessing risk of bias and applicability in diagnostic accuracy studies, developed through a 4-stage evidence-based consensus process. It replaces the original QUADAS “yes/no/unclear” quality rating with domain-level judgments of low, high, or unclear risk of bias and concerns about applicability.
Key findings
- QUADAS-2 separates “quality” into risk of bias and concerns regarding applicability, defining quality as the degree to which diagnostic accuracy estimates avoided bias and the extent to which primary studies are applicable to the review question.
- The tool has 4 key domains—patient selection, index test, reference standard, and flow and timing—with the first 3 also assessed for applicability; it is completed in 4 phases and uses signaling questions to help judge risk of bias.
- Development drew on 4 reviews: 54 diagnostic accuracy reviews published between 2007 and 2009, structured feedback from 64 systematic reviewers who had used QUADAS, 101 studies on sources of bias and variation, and 8 studies evaluating QUADAS; a 1-day consensus meeting had 24 attendees, and piloting occurred in 5 reviews.
- Interrater reliability varied considerably, with better agreement on applicability than on risk of bias; all participants preferred QUADAS-2 to the original tool, but the authors could not currently include criteria for studies comparing multiple index tests because the evidence base was insufficient.
Methods
- Tool development followed Moher and colleagues’ 4-stage approach: define the scope, review the evidence base, hold a face-to-face consensus meeting, and refine through piloting.
- A steering group of 9 experts set the scope; the consensus meeting was held on 21 September 2010 in Birmingham, United Kingdom, with 24 attendees who split into groups of 4 to 6 participants; multiple rounds of piloting used online questionnaires and other feedback, including pairs of reviewers piloting QUADAS-2 in 5 reviews.
- No primary statistical analysis was reported; the work synthesized evidence reviews, consensus decisions, and pilot feedback to produce and refine the tool.
Limitations
- Stated: the authors decided they cannot currently include criteria for assessing studies that compare multiple index tests within QUADAS-2 because of the limited evidence base on risk of bias and sources of variation in such studies, and they plan future work on this topic.
- Stated: piloting showed poor interrater reliability and problems applying the domain on comparative accuracy studies; interrater reliability varied considerably overall, with better agreement on applicability than on risk of bias.
- Evident from the text: full details of the 4 evidence reviews were to be published separately, and the main text reports no quantitative reliability estimates, referring instead to an Appendix Table.
Model-written summary. Check it against the paper before relying on it.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
0 Valid · 0 Not valid · 16 Not checked · 24 Own results and interpretations
In the paper
“In a review on anti-cyclic citrullinated peptide antibodies for diagnosing rheumatoid arthritis (10), we found that some studies enrolled consecutive participants with confirmed diagnoses. In these studies, testing for anticyclic citrullinated peptide antibody showed greater sensitivity than in studies that included patients with suspected disease but an unconfirmed diagnosis (that is, difficult-t”
§ QUADAS-2: A Revised Tool for the Quality Assessment of Diagnostic Accuracy Studies > Signaling question 2: Was a case-control design avoided? Signaling question 3: Did the study avoid inappropriate exclusions?
What the sources say
- Not matchedcites [10]
The reference list we hold has no entry [10].
plainstates an association- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Not matched
A statement the paper makes itself — it cites no source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“Studies that make inappropriate exclusions (for example, not including”
§ QUADAS-2: A Revised Tool for the Quality Assessment of Diagnostic Accuracy Studies > Signaling question 2: Was a case-control design avoided? Signaling question 3: Did the study avoid inappropriate exclusions?
hedgedstates a possible cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
None of the sources cited for this claim could be matched to a paper, so there is nothing to check it against.
In the paper
“Because the accuracy of a test may depend on where it will be used in the diagnostic pathway, review authors are asked to describe patients in terms of setting, intended use of the index test, patient presentation, and previous testing (8,9).”
§ QUADAS-2: A Revised Tool for the Quality Assessment of Diagnostic Accuracy Studies > Phase 1: Review Question
What the sources say
- Not matchedcites [8]
The reference list we hold has no entry [8].
- Not matchedcites [9]
The reference list we hold has no entry [9].
hedgedstates a possible cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Not matched
In the paper
“Development of QUADAS-2 was based on the 4-stage approach proposed by Moher and colleagues (4): define the scope, review the evidence base, hold a face-to-face consensus meeting, and refine the tool through piloting.”
§ QUADAS-2: A Revised Tool for the Quality Assessment of Diagnostic Accuracy Studies > METHODS
What the sources say
- Not matchedcites [4]
The reference list we hold has no entry [4].
plainstates a cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: unclear — It is unclear whether the paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Not matched
None of the sources cited for this claim could be matched to a paper, so there is nothing to check it against.
In the paper
“Studies enrolling participants with known disease and a control group without the condition may similarly exaggerate diagnostic accuracy (7,11).”
§ QUADAS-2: A Revised Tool for the Quality Assessment of Diagnostic Accuracy Studies > Signaling question 2: Was a case-control design avoided? Signaling question 3: Did the study avoid inappropriate exclusions?
What the sources say
- Not matchedcites [7]
The reference list we hold has no entry [7].
- Not matchedcites [11]
The reference list we hold has no entry [11].
hedgedstates a possible cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Not matched
10 more claims
Create a free account to see all 40 claims and every source verdict.
- Probably not a substantial claim. 19
- It may state two separate claims as one. 16
- The quote only partly states this claim. 2
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“We assessed the study-level risk of bias with the QUADAS-2 tool”
In the citing paper
“We developed a revised risk-of-bias assessment tool to address these issues, incorporate advances in assessment of risk of bias used in other recently developed tools, 9 10 and integrate recent developments in estimation of intervention effects from randomised trials. 11”
From RoB 2: a revised tool for assessing risk of bias in randomised trials (2019) · cites this paper as [10]
In the citing paper
“Two reviewers independently assessed the quality of the included studies with the Quality Assessment of Diagnostic Accuracy Studies (Quadas-2) [33].”
From High-standard predictive equations for estimating body composition using bioelectrical impedance analysis: a systematic review (2024) · cites this paper as [33]
In the citing paper
“The quality of the selected studies was rigorously assessed using the Checklist for Artificial Intelligence in Medical Imaging (CLAIM) alongside the Quality Assessment of Diagnostic Accuracy Studies-2 (QUADAS-2).23,24”
From Artificial Intelligence Detection and Segmentation Models: A Systematic Review and Meta-Analysis of Brain Tumors in Magnetic Resonance Imaging (2024) · cites this paper as [24]
In the citing paper
“The methodological quality of each selected study was assessed according to the Quality Assessment of Diagnostic Accuracy Studies (QUADAS-2) checklist [15]”
From The diagnostic accuracy of digital, infrared and mercury-in-glass thermometers in measuring body temperature: a systematic review and network meta-analysis (2021) · cites this paper as [15]
20 more claims about this paper
Create a free account to see every claim other papers make about this one.
Citations
Cites
The Cochrane Collaboration's tool for assessing risk of bias in randomised trials
Higgins, J. P. T., Altman, D. G., Gotzsche, P. C., Juni, P., Moher, D., Oxman, A. D., Savovic, J., Schulz, K. F., Weeks, L., Sterne, J. A. C., et al. (2011) · BMJ · doi:10.1136/bmj.d5928 · Cited by 33,817
Self-citationWhiting, P., Rutjes, A. W., Reitsma, J. B., Bossuyt, P. M., & Kleijnen, J. (2003) · BMC Medical Research Methodology · doi:10.1186/1471-2288-3-25 · Cited by 3,592
Self-citationThe Hazards of Scoring the Quality of Clinical Trials for Meta-analysis
Jüni, P. (1999) · JAMA · doi:10.1001/jama.282.11.1054 · Cited by 1,981
Empirical evidence of design-related bias in studies of diagnostic tests.
Lijmer, J. G. (1999) · JAMA · doi:10.1001/jama.282.11.1061 · Cited by 1,861 · cited 2×
“Studies enrolling participants with known disease and a control group without the condition may similarly exaggerate diagnostic accuracy (7, 11).”
BackgroundGuidance for Developers of Health Research Reporting Guidelines
Moher, D., Schulz, K. F., Simera, I., & Altman, D. G. (2010) · PLoS Medicine · doi:10.1371/journal.pmed.1000217 · Cited by 1,437
Systematic Reviews of Diagnostic Test Accuracy
Leeflang, M. M. G., Deeks, J. J., Gatsonis, C., & Bossuyt, P. M. M. (2008) · Annals of Internal Medicine · doi:10.7326/0003-4819-149-12-200812160-00008 · Cited by 1,124
Self-citationSources of Variation and Bias in Studies of Diagnostic Accuracy: A Systematic Review
Whiting, P., Rutjes, A. W. S., Reitsma, J. B., Glas, A. S., Bossuyt, P. M. M., & Kleijnen, J. (2004) · Annals of Internal Medicine · doi:10.7326/0003-4819-140-3-200402030-00010 · Cited by 798 · cited 4×
“The third review was an update on sources of bias and variation in diagnostic accuracy studies that included 101 studies (7).”
BackgroundInfluentialSelf-citationEvaluation of QUADAS, a tool for the quality assessment of diagnostic accuracy studies
Whiting, P. F., Weswood, M. E., Rutjes, A. W., Reitsma, J. B., Bossuyt, P. N., & Kleijnen, J. (2006) · BMC Medical Research Methodology · doi:10.1186/1471-2288-6-9 · Cited by 769
Self-citationLeeflang, M. M. G., Moons, K. G. M., Reitsma, J. B., & Zwinderman, A. H. (2008) · Clinical Chemistry · doi:10.1373/clinchem.2007.096032 · Cited by 346 · cited 1×
“Test performance is likely to be poorer in an independent sample of patients in whom the same threshold is used (12).”
BackgroundSelf-citationNo role for quality scores in systematic reviews of diagnostic accuracy studies
Whiting, P., Harbord, R., & Kleijnen, J. (2005) · BMC Medical Research Methodology · doi:10.1186/1471-2288-5-19 · Cited by 337
Self-citation
Cited by
Items 13,801–13,900 of 14,770
Luke, M., Ojo, A., Oduola, A., Olorunmonu, T., Ojo, B., Luke, B., Olaitan, A., Adeyeye, O., & Oluwasina, F. (2026) · International Journal of Research and Innovation in Social Science · doi:10.47772/ijriss.2026.100500154
Nadarge, M. C., & Achath, D. D. (2026) · Cureus · doi:10.7759/cureus.109628
“Risk of bias was assessed using the Quality Assessment of Diagnostic Accuracy Studies-2 (QUADAS-2) tool for studies evaluating diagnostic accuracy [15].”
Zhang, H.-P., Li, N., Li, F., & Zhou, Y. (2026) · World Journal of Radiology · doi:10.4329/wjr.v18.i5.119213
Krishnakumar, M., Folestad, A., Lakshmanan, V., Nandakumar, A., Sathyapalan, D. T., Karuveettil, V., Janakiram, C., & Gutjahr, G. (2016) · JBI Evidence Synthesis · doi:10.11124/jbies-25-00321
Teodoro, A. B., Tobias, R. S. F., Evangelista, K., Leite, A. F., Cevidanes, L., Silva, R. F., Valladares‐Neto, J., & Silva, M. A. G. (2026) · Dentomaxillofacial Radiology · doi:10.1093/dmfr/twag033
Willyanto, S. E., Puling, I. M. D. R., Giri, N. D. P., Wijaya, J. A., Dewi, L., Rampengan, D. D. C. H., & Putri, V. Y. S. (2026) · Annals of Pediatric Cardiology · doi:10.4103/apc.apc_198_25
“[17] Subsequently, the data extracted from diagnostic studies were entered into the “bias” section of a Microsoft Excel 2021 spreadsheet, and visually presented the assessment results using the traffic light system.”
Accuracy of major trauma triage using the MATTS tool: a cohort study
Fuller, G. W., Baird, J., Herbert, E., Keating, S., Miller, J., Pilbery, R., Turner, J., Lecky, F. E., Edwards, A., Rosser, A., et al. (2026) · Emergency Medicine Journal · doi:10.1136/emermed-2024-214159
Artificial intelligence for reducing metal artifacts in dental CBCT images: a systematic review
Soltani, P., Iranmanesh, P., Ebrahimzadeh, F., Angelone, F., Ponsiglione, A. M., Amato, F., Moaddabi, A., Armogida, N. G., Spagnuolo, G., Rengo, C., et al. (2026) · Dentomaxillofacial Radiology · doi:10.1093/dmfr/twag034 · Cited by 1
Lv, H., Jin, S., Li, L., Ma, S., Wang, Y., Zhang, Y., & Guo, K. (2026) · International Journal of Infectious Diseases · doi:10.1016/j.ijid.2026.108827
Messineo, D., Frisina, P., Begvarfaj, E., & Panebianco, V. (2026) · Medical Sciences · doi:10.3390/medsci14020274
Du, D., He, S., Guo, S., Liao, Y., Qin, J., Chen, Z., Liu, S., Luo, F., Shen, Y., & Wen, F. (2026) · Public Health · doi:10.1016/j.puhe.2026.106349
MOLINA-LINDE, J. M., Martín-López, J. E., Rosario-Lozano, M. P., & Blasco‐Amaro, J. A. (2026) · Journal of Ultrasound · doi:10.1007/s40477-026-01171-7
“The methodological quality and risk of bias of the included studies were assessed using the Quality Assessment of Diagnostic Accuracy Studies-2 (QUADAS-2) tool [7].”
Shi, Q., Zhu, L., Wang, W., & Li, X. (2026) · BMC Medical Informatics and Decision Making · doi:10.1186/s12911-026-03599-7
“To assess study quality, we used a modified QUADAS-2 tool [14] and added prediction model risk of bias assessment tool (PROBAST)-informed signaling questions relevant to prediction-model bias [15], including validation method, predictor-reference overlap, model selection, and analysis…”
Antolí, A., & Chía, L. (2026) · Acta Psychologica · doi:10.1016/j.actpsy.2026.107156 · Cited by 1
Fazendas, P., Caldeira, D., Pereira, H., & Almeida, A. G. (2026) · Journal of Echocardiography · doi:10.1007/s12574-026-00734-1
Liu, J., Zhong, P., Ma, W., & Duan, Y. (2026) · Clinical & Translational Oncology · doi:10.1007/s12094-026-04431-4
“The quality of the included studies was assessed using the modified Quality Assessment of Diagnostic Accuracy Studies 2 (QUADAS-2) tool [24].”
Retinal biomarkers for the detection of cognitive frailty in older adults: a systematic reviewPreprint
Meziane-Benaissa, S. (2026) · Research Square · doi:10.21203/rs.3.rs-9849675/v1
Teixeira, I. S., Botogoski, S. R., & Nisihara, R. (2026) · Revista Brasileira Ginecologia e Obstetrícia · doi:10.61622/rbgo/2026rbgo16
Mahfouz, M., & Alzaben, E. (2026) · Research Square · doi:10.21203/rs.3.rs-9879471/v1
Taigonyrov, A., Rai, H. M., Jamwal, P. K., Pal, A., & Razaque, A. (2026) · Archives of Computational Methods in Engineering · doi:10.1007/s11831-026-10657-w
“Risk of bias and applicability were assessed for all 50 included studies using a modified QUADAS-2 framework [41 ].”
InfluentialZhang, S., Wang, S.-H., Zhao, Y., Wei, J.-H., Sui, X.-Y., Li, X. R., ZHANG, H.-W., Zhi-Yao, H., Wang, C.-L., Hu, H., et al. (2026) · World Journal of Gastroenterology · doi:10.3748/wjg.118009
Urquhart, O., Verdugo‐Paiva, F., Martins-Pfeifer, C. C., Bhosale, A. S., Massignan, C., Meisha, D. E., O’Brien, K. K., Rojas-Gómez, A. M., Glick, M., Lingen, M. W., et al. (2026) · The Journal of the American Dental Association · doi:10.1016/j.adaj.2026.03.028 · Cited by 1
Asadirad, F., Rezaei, M., Ghannadikhosh, P., Salehpour, H., Motamedi, A., Mobadersani, M., soleimannezhad, N., Rad, S. G., Gharepapagh, E., Rezaei, S., et al. (2026) · Neuroimage Reports · doi:10.1016/j.ynirp.2026.100354
“This multi-tool approach, aligned with the Cochrane Handbook for Systematic Reviews of Interventions (Higgins, 2008) and best practices for heterogeneous systematic reviews (Moons et al., 2015; Whiting et al., 2011), ensured a comprehensive and robust quality evaluation.”
Alqahtani, N. G., Moawad, M. H. E. D., Shati, A. A., Bisht, O., Abdul‐Hafez, H. A., Shatoor, A. S., Alharasees, M., Elkelish, A., Alshanbari, A. S., & Zabady, A. H. (2026) · BMC Medical Imaging · doi:10.1186/s12880-026-02471-4
“The quality of the studies was evaluated using the QUA-DAS-2 tool [21].”
Middle Range Theory for the Nursing Diagnosis of Excessive Caregiving Burden
Borges, B. E. C., Dantas, A. C., de Carvalho, L. M., Araújo, J. N. D. M., Oliveira, A. B. D. S., Fernandes, M. I. D. C. D., Lopes, M. V. D. O., & Vítor, A. F. (2026) · International Journal of Nursing Knowledge · doi:10.1177/20473087261443248
“The selected studies underwent critical methodological evaluation using the adapted instrument Quality Assessment of Diagnostic Accuracy Studies (QUADAS-2), with the criterion for inclusion being a minimum performance of 70% across its four domains (Whiting et al., 2011).”
Lu, L., Li, H., Liu, Y.-M., Du, H.-X., Qin, J., Yeung, W.-F., Zhong, C. C., Xiong, L., & Chen, S.-C. (2026) · Information · doi:10.3390/info17060554
Romeikat, N. L., Morgan-Young, R., McCartney, M., & Sullivan, F. (2026) · BMJ Connections Oncology · doi:10.1136/bmjconc-2025-000103
Méndez, J., Mello-Román, J. C., Villasanti, U., Niederberger, A., Gaona, M. I. F., Noguera, J. L. V., Torres, R. D. E., Servín, J., Ramirez, C. M. M., González, M. S. V., et al. (2026) · Intelligence-Based Medicine · doi:10.1016/j.ibmed.2026.100401
Xu, P., You, W., Liu, S., & Zhang, C. (2026) · World Journal of Emergency Medicine · doi:10.5847/wjem.j.1920-8642.2026.066
Salido, E. O., Mendoza, N. R. N. P., Manapat-Reyes, B. H., Orillaza, N. S., Leochico, C. F. D., Burog, A. I. L. D., Bayona, H. H. G., Chan, K. J. C., Espino, V. L. A., Francisco, M. D., et al. (2026) · Acta Medica Philippina · doi:10.47895/amp.v60i10.10951
Alghamdi, A., Almousa, H. M., Binghaith, A., Almughamisi, R. H., Fnais, N., Alzahrani, F., Alessa, M., AlQahtani, K., & Aldhahri, S. F. (2026) · European Archives of Oto-Rhino-Laryngology · doi:10.1007/s00405-026-10316-7
“Furthermore, QUADAS-2 tool [ 19] was used as supplementary tool, which evaluates risk of bias and applicability across four domains: Patient Selection, Index Test, Reference Standard, and Flow & Timing.”
Abedi, A. A., Tarabichi, S., Glaudemans, A. W. J. M., Parvizi, J., & the Imaging Working Group for the Unified PJI Definition Task Force (2026) · Knee Surgery Sports Traumatology Arthroscopy · doi:10.1002/ksa.70423
Allicock, O. M., Dogra, A., Cho, J. H. M., Rojas, K., Hasson, H. O., Omene, B., Funaro, M. C., Laxton, C. S., & Yildirim, I. B. (2026) · medRxiv · doi:10.64898/2026.06.02.26354258
A systematic review of algorithmic challenges in noise modelling for multimodal single-cell
Mallampalli, S. S., Madan, A., & Jain, C. K. (2026) · Computational Biology and Chemistry · doi:10.1016/j.compbiolchem.2026.109161
Kayda, I., Lechiile, K., Kinshella, M. W., Bone, J. N., Lavoie, P. M., & Goldfarb, D. A. (2026) · Virology Journal · doi:10.1186/s12985-026-03206-1
Jaiyeoba-Ojigho, E. J., Anibor, E., Pandey, P., Sunday, O. G., Innocent, D. C., Anyakorah, P. E., & Okolie, E. I. (2026) · BMC Neurology · doi:10.1186/s12883-026-05046-6
“Methodological quality and risk of bias of included studies were measured with the use of the QUADAS-2 (Quality Assessment of Diagnostic Accuracy Studies-2), which is a validated and highly recommended tool of quality assessment of studies about diagnostic accuracy [16].”
InfluentialMaintaining validity of neuropathic pain screening tools over time: challenges and opportunities
Mesaroli, G., Perruccio, A. V., Davidge, K. M., & Stinson, J. (2026) · Journal of Patient-Reported Outcomes · doi:10.1186/s41687-026-01086-1
Urine and cerebrospinal fluid biomarkers for early glioma detection: a systematic review
Paterson, C., Yu, J., Davies, P., Read, J., Palmer, J. C., Dawson, S., Higgins, J. P. T., & Kurian, K. M. (2026) · Diagnostic and Prognostic Research · doi:10.1186/s41512-026-00230-1
“[12] In line with QUADAS-2 guidance, formal assessments were preceded by a pilot stage conducted by four reviewers (CP, JY, PD, and JR) with input from two principal investigators.”
Deep Learning for Postpartum Depression Prediction Using Behavioral Data: A Systematic Review
Keshinro, O. S., Musa, A., Abayomi, A., Masisi, B. K., & Zungeru, A. M. (2026) · IEEE Access · doi:10.1109/access.2026.3700925
Lassi, S., Niaz, M., Ansari, Z. N., Iftikar, H., Rizvi, S., Amir, H., Hasnain, Z., Jafri, S. K., & Das, J. K. (2026) · Psychology International · doi:10.3390/psycholint8020035 · Cited by 1
“Two authors independently performed quality assessments for this review using the Quality Assessment for Diagnostic Accuracy Studies 2 (QUADAS-2) tool (Whiting et al., 2011).”
Bonezzi, L., Rocchitelli, L., Biagioni, T., Chorna, O. D., Pannek, K., Luke, C. R., Ware, R. S., Fripp, J., Guzzetta, A., Fiori, S., et al. (2026) · Neonatology · doi:10.1159/000552875
“Study quality was assessed using the Quality Assessment of Diagnostic Accuracy Studies-2 (QUADAS-2) [25] tool and its extension Quality Assessment of Diagnostic Accuracy Studies-Comparative (QUADAS-C) [26], for comparative diagnostic accuracy studies.”
D-dimer diagnostic performance for splanchnic vein thrombosis: A systematic review
Cordeanu, E., Soudet, S., & Stéphan, D. (2026) · JVS-Vascular Insights · doi:10.1016/j.jvsvi.2026.100464
Steiner, Q., Lee, E., Anderson, P. A., & Spiker, A. M. (2026) · JAAOS Global Research and Reviews · doi:10.5435/jaaosglobal-d-25-00157
Yang, D., Gu, M., Tang, X., He, L., (48506), J. Z., Wang, X., Hou, Y., Cui, Y., Li, C., Tian, J., et al. (2026) · BMC Infectious Diseases · doi:10.1186/s12879-026-13473-6
“…therapy, vancomycin may effectively clear the majority of susceptible cells but fail to eradicate the resistant subpopulations, resulting in delayed blood-stream clearance and a prolonged infection course that increases the risk of treatment exhaustion and subsequent clinical failure [13, 20, 28].”
Zheng, L., Rusip, G., & Girsang, E. (2026) · International Journal of Drug Delivery Technology · doi:10.25258/ijddt.16.47s.60
Keetha, N. R., Contreras, R., Saberian, P., Hoteit, M., Nasrollahizadeh, A., Sonde, D. M., Hashemi, S. M., Parackal, V., Hassanabad, A. F., Amini‐Salehi, E., et al. (2026) · Medicine · doi:10.1097/md.0000000000048988
Kaufmann, G., Boaro, A. P., Goergen, A., Juchem, C. F., Santos, R. O., Corbellini, V. A., Hoehne, L., & Heidrich, D. (2026) · Spectrochimica Acta Part A Molecular and Biomolecular Spectroscopy · doi:10.1016/j.saa.2026.128219
Moussaoui, D. E., Korchiyne, R., Alaoui, M. T., & Sbai, M. (2026) · International Conference on Innovative Research in Applied Science, Engineering and Technology (IRASET) · doi:10.1109/iraset68627.2026.11538848
“While multiomics supports personalized medicine, it raises ethical and privacy concerns [17], [18].”
Carvalho, G. I. P., Ji, G., Li, Q., & Wen, L. (2026) · IEEE Access · doi:10.1109/access.2026.3701060
“The diagnostic-accuracy tool QUADAS-2 [49] is widely used for medical-imaging classification studies, and PROBAST [50] is the standard for prediction-model studies, but neither was designed for computer-vision systems trained on staged simulations and deployed in 97606 VOLUME 14, 2026 Authorized…”
Campos, G. E. E., Palacios, J. A. A., Quinto, M. B. E., Ramos, M. L. A., & Arias, M. I. V. (2026) · Ciencia y Educación · doi:10.5281/zenodo.20586370
Telles-Araújo, G. D. T., da Cruz, K. M., Peralta-Mamani, M., Gonzalez, T. F. L. D. O., Ribeiro, P. M. L., Lins-Kusterer, L., & Sarmento, V. A. (2026) · Imaging Science in Dentistry · doi:10.5624/isd.20250279
“The risk of bias of the included studies were independently assessed by two reviewers (GTTA and KMC) using the QUADAS-2 tool (Quality Assessment of Diagnostic Accuracy Studies-2), 24 which is validated for evaluating diagnostic accuracy studies.”
Cai, F., Gu, Y., Gao, J., Yi, G., & Zhang, Y. (2026) · Phenomics · doi:10.1007/s43657-025-00288-9
“A p value greater than 0.05 was considered to indicate no significant asymmetry, suggesting the absence of publication bias (Whiting et al. 2011).”
InfluentialKothakapa, S. L., Ramireddy, S., Thanugundla, S. R., Chittireddy, S., Nenavath, P. R., Prodduku, A., Lakavath, C., Poloju, N., Thota, N. T., koolla, P., et al. (2026) · Cureus · doi:10.7759/cureus.110459
“The methodological quality of the included studies was evaluated using the QUADAS-2 tool [45].”
InfluentialPatel, S., Nischal, S. A., Nallankuka, G. S., Kale, K. M., Sarikonda, A., Saad, H., Hines, K., Jallo, J., Harrop, J. S., & Prasad, S. K. (2026) · The Spine Journal · doi:10.1016/j.spinee.2026.06.004
Grochowska‐Rak, M., Kulig, K., Grabowska, A., Karlińska‐Jonkisz, V., Racisz, P., Czop, M., Pas, H. H., Lesiak, A., Barasińska, P., Matych, M., et al. (2026) · International Journal of Dermatology · doi:10.1111/ijd.70524
Yang, W., Li, S., Du, Y., Chen, M., Yang, F., Zhang, F., Zhao, J., Li, Y., & Xu, X. (2026) · npj Digital Medicine · doi:10.1038/s41746-026-02729-9
“Technology validation studies were assessed using the QUADAS-2 92 , with signalling questions adapted to re fl ect AI system-speci fi c methodological considerations.”
Thostrup, A. H., Stubbe, N. U., Schreiner, M. P., Bentestuen, M., Olesen, A. V., & Zacho, H. D. (2026) · Seminars in Nuclear Medicine · doi:10.1053/j.semnuclmed.2026.05.010 · Cited by 1
Diagnostic and Prognostic Value of Hypoxia PET in Glioma: A Systematic Review and Meta-Analysis
Ladak, A. M., Mirshahvalad, S. A., Farag, A., Metser, U., Ortega, C., Murad, V., & Veit‐Haibach, P. (2026) · Cancers · doi:10.3390/cancers18121898
Wael, N., Owid, A.-Z., & Fadlalla, H. (2026) · Expert Review of Molecular Diagnostics · doi:10.1080/14737159.2026.2687512
“The methodological quality of the included studies was assessed using the QUADAS-2 (Quality Assessment of Diagnostic Accuracy Studies-2) tool [19], evaluating the risk of bias and applicability concerns across four domains: patient selection, index test, reference standard, and flow and timing.”
InfluentialCheng, L., Zhang, B., Hu, X., Wang, W., Wan, H., Liao, J., Pan, C., & Xie, D. (2026) · Frontiers in Medicine · doi:10.3389/fmed.2026.1769556
“Furthermore, the methodological quality of the included studies was independently assessed by two reviewers (CLP and ZB) using the Quality Assessment of Diagnostic Accuracy Studies-2 (QUADAS-2) tool (8).”
Arachchige, A. S. P. M., Dashiell, A., Beghelli, V., Caserta, T., Sajjad, Z., Moreira, G. A. A., & Svet, A. (2026) · Research Square · doi:10.21203/rs.3.rs-9973682/v1
Campbell, H. C., Bowden, S. C., Saw, G., & Cheung, M. W. ‐. (2026) · Psychological Assessment · doi:10.1037/pas0001478
Explainable Artificial Intelligence in Valvular Heart Disease: A Systematic Review
Sathish, J., Rajakumar, H. K., Abhilash, B. A., & Murugan, A. (2026) · Indian Journal of Clinical Cardiology · doi:10.1177/26324636261455164
Liu, T., Lu, Y., Wang, K., Li, X. P., Wu, L., Pan, Z., & Yao, H. (2026) · Journal of Dairy Science · doi:10.3168/jds.2025-27531
Rujirussawarawong, S., Ounmuang, C., Aungsumart, S., Kasemsuk, C., & Limotai, N. (2026) · Movement Disorders Clinical Practice · doi:10.1002/mdc3.70707
Kondo, S., Yamamoto, N., Saitsu, A., Ishikane, M., Hirao, Y., Corpuz, A., & Someko, H. (2026) · Cureus · doi:10.7759/cureus.110730
“Two of the four reviewers (SK, AS, YH, AC) independently evaluated risk of bias and applicability using the Quality Assessment of Diagnostic Accuracy Studies 2 (QUADAS-2) tool [29], adapted for this review (Supplemental Material 6).”
Kotochinsky, M., Silva, Y. P., Goyal, A., Łajczak, P., Rios-García, W., Suruagy-Motta, R., Petry, I. N. S., Fagundes, T. P., & Bertani, R. (2026) · Neuro-Oncology Practice · doi:10.1093/nop/npag055 · Cited by 1
Wang, Y., Wang, Y., Kang, J., He, S., & Zhang, P. (2026) · Biomarkers in Medicine · doi:10.1080/17520363.2026.2685066
de Almeida, L. D. N. G., Lopes, F. C., de Castro, L. F. F., & Requeijo, M. J. R. (2026) · Research Society and Development · doi:10.33448/rsd-v15i6.51204
Al-Juhani, A. A., Binshalhoub, A. A., Aljohani, N., Aljohani, O. O., Alasmari, A. F., & Badghaish, M. K. (2026) · The Saudi Journal of Forensic Medicine and Sciences · doi:10.4103/sjfms.sjfms_11_25
Al-Juhani, A. A., Binshalhoub, A. A., Aljohani, N., Aljohani, O. O., Alasmari, A. F., & Badghaish, M. K. (2026) · The Saudi Journal of Forensic Medicine and Sciences · doi:10.4103/sjfms.sjfms_12_25
Fang, S., & Chen, S. (2026) · Surgical and Experimental Pathology · doi:10.1186/s42047-026-00248-1
“Quality assessment was performed using the Quality Assessment of Diagnostic Accuracy Studies (QUA-DAS-2) tool for diagnostic accuracy studies and the Prediction model Risk Of Bias ASsessment Tool (PRO-BAST) for prediction model studies (Whiting et al. 2011, Wolff et al. 2019).”
Das, S., Tripathy, D., & Ponnu, P. (2026) · Cureus · doi:10.7759/cureus.110769
Diagnostic Accuracy Studies: Sensitivity, Specificity, and Beyond
Végas, N., Friedlander, L., & Cohen, J. F. (2026) · Journal of Periodontal Research · doi:10.1111/jre.70128
“One of the most widely used frameworks for assessing the quality of diagnostic accuracy studies is the QUADAS-2 tool (Quality Assessment of Diagnostic Accuracy Studies version 2) [24].”
Papatheodorou, N., Pavlović, P., Salcedo, J., & Mariș, M. I. (2026) · The International Journal of Lower Extremity Wounds · doi:10.1177/15347346261459550
Jiang, Q., Cai, L.-B., & Zhou, S. (2026) · Ear Nose & Throat Journal · doi:10.1177/01455613261461441
Szponar, M., Gmaj, B., Orłowski, J., & Kamiński, J. (2026) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2026.110779
Nanopore Sequencing in Mycobacterial Diagnostics: Clinical and Laboratory Roles of mNGS and tNGS
Wang, M. (2026) · Diagnostics · doi:10.3390/diagnostics16121850
Lukacs, S., Messner, L., Flaig, M. J., Ohlmann, A., Hartmann, D., & Kendziora, B. (2026) · Acta Dermato Venereologica · doi:10.2340/actadv.v106.adv-2026-0393
“The risk of bias and applicability concerns for each included study were evaluated using the Quality Assessment of Diagnostic Accuracy Studies (QUADAS-2) tool (15).”
Srour, A., Omar, M., Barash, Y., Litmanovich, D., Srour-Asmar, M., Gorenshtein, A., & Klang, E. (2026) · Research Square · doi:10.21203/rs.3.rs-10028122/v1
Niyibizi, J. B., Jansen, S., Larsson, E. C., Ntabanganyimana, J., & Arunda, M. O. (2026) · Frontiers in Psychiatry · doi:10.3389/fpsyt.2026.1728252 · Cited by 1
“The QUADAS-2 tool results were not based on overall quality score; rather, they were evaluated at item level using domain-based judgment approach and were presented using tabular presentation and graphical displays (traf fi c light bar plots) as suggested by Whiting PF and colleagues (28).”
InfluentialSelefon, M. A., Cobuz, C., Vernic, C., Jianu, D. C., Milas, L. O., & Vlad, A. (2026) · Diabetology · doi:10.3390/diabetology7060115 · Cited by 1
“Many studies used case–control designs or enriched clinic samples that may inflate diagnostic performance compared with general screening populations (patient selection bias) [10].”
InfluentialPittelkow, M.-M., Mönch, M., Mokkink, L. B., Streiner, D. L., Brorson, S., Shoukri, M. M., & Kottner, J. (2026) · BMJ Open · doi:10.1136/bmjopen-2025-109876
“…23 24 offers a comprehensive set of recommendations to ensure transparent and complete reporting, while the Quality Assessment of Diagnostic Accuracy Studies (QUADAS) tool 25 26 provides a structured approach for evaluating risk of bias of diagnostic accuracy studies included in systematic reviews.”
MicroRNA Signatures in Cardiovascular Diseases: A Systematic Literature Review
Mahapatra, H., Banotra, P., Anand Sekar, G., Sharma, J., Sharat Vishwanath, K., & Tripathi, D. (2026) · Cureus · doi:10.7759/cureus.110938
“QUADAS-2 informed judgments on patient selection, biomarker measurement, diagnostic relevance, and study flow, while NOS principles informed assessment of cohort selection, comparability, and outcome reporting [15,16].”
D’Alberti, E., Sorrenti, S., Kagan, K. O., Gil, M. M., Zullo, F., Grammatico, P., Pizzuti, A., Giancotti, A., & Mascio, D. D. (2026) · European Journal of Obstetrics & Gynecology and Reproductive Biology · doi:10.1016/j.ejogrb.2026.115258
Tomassini, L., Onofri, M., Gambelunghe, C., Fedeli, P., Scendoni, R., Pini, N., & Lancia, M. (2026) · Legal Medicine · doi:10.1016/j.legalmed.2026.102894
Bukhari, S. M., Kumar, I., & Saini, D. (2026) · Archives of Computational Methods in Engineering · doi:10.1007/s11831-026-10705-5 · Cited by 1
“To assess the quality of included studies, a modified ver - sion of the Quality Assessment of Diagnostic Accuracy Studies (QUADAS 2) tool was applied [ 14].”
Abdalla, A. B. B., Mohamed, M. A. E., Eisa, S. I. O., Mohamedani, R., Ahmed, L. M. S., Hamzeh, E., & Abdalla, A. K. M. (2026) · Cureus · doi:10.7759/cureus.111120
Ulaner, G. A., Parihar, A. S., Calais, J., Sutcliffe, S., & Schoones, J. W. (2026) · Radiology Imaging Cancer · doi:10.1148/rycan.250732
Moews, L. D., Alfonsi, S. P., Musahl, V., Hirschmann, M. T., Cole, B. J., Chahla, J. A., & Kunze, K. N. (2026) · Knee Surgery Sports Traumatology Arthroscopy · doi:10.1002/ksa.70489
“Additionally, The Quality Assessment of Diagnostic Accuracy Studies 2 (QUADAS ‐ 2) was used; a validated framework for assessing the quality of diagnostic accuracy studies across four domains: patient selection, index test, reference standard, and fl ow/ timing [41].”
Ticku, S., Bawane, S. S., & Kadadhekar, S. S. (2026) · Journal of Maxillofacial and Oral Surgery · doi:10.1007/s12663-026-03130-5
Identification of Maintenance Dialysis Recipients in Administrative Health Data: A Systematic Review
Shaw, A., Jarrar, F., Quinn, R. R., Harrison, T. G., Elliott, M. J., James, M. T., Ravani, P., & Liu, P. (2026) · American Journal of Kidney Diseases · doi:10.1053/j.ajkd.2026.04.009
Valentin, A., Windhorst, A. C., Sachs, U. J., Wienzek‐Lischka, S., Bedei, I. A., Wolter, A., & Axt-Fliedner, R. (2026) · Transfusion Medicine Reviews · doi:10.1016/j.tmrv.2026.151017
Srivali, N., & Giacomi, F. D. (2026) · Heart & Lung · doi:10.1016/j.hrtlng.2026.102876
Li, C., MENG, Q., Wells, S., Barbieri, S., Jackson, R., & Poppe, K. (2026) · International Journal of Medical Informatics · doi:10.1016/j.ijmedinf.2026.106549
Vision-language foundation models for 3D neuroradiological interpretation: A systematic review
Gurary, S. T., Ndengera, M., Korchi, A., Reith, N., Esparza, J. F. O., Botta, D., Lövblad, K. O., & Kurz, F. T. (2026) · European Journal of Radiology Artificial Intelligence · doi:10.1016/j.ejrai.2026.100111
Coté, J. J., Coté, R. D., Kennedy, K., Block, M. S., Farias‐Eisner, R., Walters, R. W., & Conrad, L. B. (2026) · Journal of Minimally Invasive Gynecology · doi:10.1016/j.jmig.2026.06.015
Shen, Y., & Juan, L. (2026) · The American Journal of Emergency Medicine · doi:10.1016/j.ajem.2026.06.034 · Cited by 1
Abdurakhmanova, E. G., Bolatbek, A., Zholshybek, N., Mustafa, Z., Almazan, J. U., & Bolla, S. R. (2026) · BMJ Open · doi:10.1136/bmjopen-2026-117491
Metadata
- Authors
- Whiting, P. F., Rutjes, A. W. S., Westwood, M. E., Mallett, S., Deeks, J. J., Reitsma, J. B., Leeflang, M. M. G., Sterne, J. A. C., Bossuyt, P. M. M., & the QUADAS-2 Group*
- Affiliations
- University of Bern (CH)
- Corresponding author
- Whiting, Penny F.
- ORCID
- Venue
- Annals of Internal Medicine
- Publisher
- American College of Physicians
- Published
- 2011-10-18
- Volume
- 155
- Issue
- 8
- Pages
- 529-536
- ISSN
- 0003-4819 (ISSN-L)
- 1539-3704
- OpenAlex
- W2107638293
- Semantic Scholar
- 8a5d0b5a9271ea14bcb8479bc32d3844a80655b9
- Cited by
- 14,199
- References
- 18
- Citations by year
- 2026: 1484 · 2025: 1569 · 2024: 1524 · 2023: 1305 · 2022: 1420 · 2021: 1514 · 2020: 1245 · 2019: 955 · 2018: 767 · 2017: 637 · 2016: 580 · 2015: 528 · 2014: 363 · 2013: 217 · 2012: 75
- FWCI
- 224.36
- Type
- journal article
- Language
- en
- Open access
- green
- hdl.handle.net
- Licence
- cc-by
- www.acpjournals.org/journal/aim/text-and-data-mining (tdm)
- Locations
- Annals of Internal Medicine (publishedVersion)
- PubMed (publishedVersion)
- Pure Amsterdam UMC (publishedVersion)
- Data Archiving and Networked Services (DANS) (submittedVersion)
- Florence Research (University of Florence) (submittedVersion)
- IRIS UNIMORE (University of Modena and Reggio Emilia) (submittedVersion, cc-by)
- University of Birmingham Research Portal (University of Birmingham) (submittedVersion)
- Bristol Research (University of Bristol) (submittedVersion)
- Funders
- Cancer Research UK
- Topics
- Social Sciences › Decision Sciences › Statistics, Probability and Uncertainty › Meta-analysis and systematic reviews
- Physical Sciences › Mathematics › Statistics and Probability › Statistical Methods in Epidemiology
- Health Sciences › Medicine › Public Health, Environmental and Occupational Health › Clinical practice guidelines implementation
- Keywords
- QUADAS-2, diagnostic accuracy studies, quality assessment, risk of bias, applicability, patient selection, index tests, reference materials, flowcharts, systematic reviews
- MeSH terms
- Diagnosis, Humans, Quality Control, Surveys and Questionnaires, Reference Standards, Review Literature as Topic, Time Factors, Bias, Patient Selection, Evidence-Based Medicine
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
A language model drew the claims from the paper on 2026-11-23, under version 3 of the claim definition (model deepseek-v4.1-flash, prompt extract-v3).
A second model labelled each claim on 2026-11-23 (model jev-1.13-20260917, definition revision gold-guideline-v0.2).
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.