QUADAS-2: A Revised Tool for the Quality Assessment of Diagnostic Accuracy Studies
Open accessThe DOI matches its Crossref record; 18 of the 18 references it cites were found in a registry or an index; none of the 21 sources its claims cite is checked for support yet.
Abstract
In 2003, the QUADAS tool for systematic reviews of diagnostic accuracy studies was developed. Experience, anecdotal reports, and feedback suggested areas for improvement; therefore, QUADAS-2 was developed. This tool comprises 4 domains: patient selection, index test, reference standard, and flow and timing. Each domain is assessed in terms of risk of bias, and the first 3 domains are also assessed in terms of concerns regarding applicability. Signalling questions are included to help judge risk of bias. The QUADAS-2 tool is applied in 4 phases: summarize the review question, tailor the tool and produce review-specific guidance, construct a flow diagram for the primary study, and judge bias and applicability. This tool will allow for more transparent rating of bias and applicability of primary diagnostic accuracy studies.
Overview
CoChat Summary
TL;DR
QUADAS-2 is a revised tool for assessing risk of bias and applicability in diagnostic accuracy studies, developed through a 4-stage evidence-based consensus process. It replaces the original QUADAS “yes/no/unclear” quality rating with domain-level judgments of low, high, or unclear risk of bias and concerns about applicability.
Key findings
- QUADAS-2 separates “quality” into risk of bias and concerns regarding applicability, defining quality as the degree to which diagnostic accuracy estimates avoided bias and the extent to which primary studies are applicable to the review question.
- The tool has 4 key domains—patient selection, index test, reference standard, and flow and timing—with the first 3 also assessed for applicability; it is completed in 4 phases and uses signaling questions to help judge risk of bias.
- Development drew on 4 reviews: 54 diagnostic accuracy reviews published between 2007 and 2009, structured feedback from 64 systematic reviewers who had used QUADAS, 101 studies on sources of bias and variation, and 8 studies evaluating QUADAS; a 1-day consensus meeting had 24 attendees, and piloting occurred in 5 reviews.
- Interrater reliability varied considerably, with better agreement on applicability than on risk of bias; all participants preferred QUADAS-2 to the original tool, but the authors could not currently include criteria for studies comparing multiple index tests because the evidence base was insufficient.
Methods
- Tool development followed Moher and colleagues’ 4-stage approach: define the scope, review the evidence base, hold a face-to-face consensus meeting, and refine through piloting.
- A steering group of 9 experts set the scope; the consensus meeting was held on 21 September 2010 in Birmingham, United Kingdom, with 24 attendees who split into groups of 4 to 6 participants; multiple rounds of piloting used online questionnaires and other feedback, including pairs of reviewers piloting QUADAS-2 in 5 reviews.
- No primary statistical analysis was reported; the work synthesized evidence reviews, consensus decisions, and pilot feedback to produce and refine the tool.
Limitations
- Stated: the authors decided they cannot currently include criteria for assessing studies that compare multiple index tests within QUADAS-2 because of the limited evidence base on risk of bias and sources of variation in such studies, and they plan future work on this topic.
- Stated: piloting showed poor interrater reliability and problems applying the domain on comparative accuracy studies; interrater reliability varied considerably overall, with better agreement on applicability than on risk of bias.
- Evident from the text: full details of the 4 evidence reviews were to be published separately, and the main text reports no quantitative reliability estimates, referring instead to an Appendix Table.
Model-written summary. Check it against the paper before relying on it.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
0 Valid · 0 Not valid · 16 Not checked · 24 Own results and interpretations
In the paper
“In a review on anti-cyclic citrullinated peptide antibodies for diagnosing rheumatoid arthritis (10), we found that some studies enrolled consecutive participants with confirmed diagnoses. In these studies, testing for anticyclic citrullinated peptide antibody showed greater sensitivity than in studies that included patients with suspected disease but an unconfirmed diagnosis (that is, difficult-t”
§ QUADAS-2: A Revised Tool for the Quality Assessment of Diagnostic Accuracy Studies > Signaling question 2: Was a case-control design avoided? Signaling question 3: Did the study avoid inappropriate exclusions?
What the sources say
- Not matchedcites [10]
The reference list we hold has no entry [10].
plainstates an association- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Not matched
A statement the paper makes itself — it cites no source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“Studies that make inappropriate exclusions (for example, not including”
§ QUADAS-2: A Revised Tool for the Quality Assessment of Diagnostic Accuracy Studies > Signaling question 2: Was a case-control design avoided? Signaling question 3: Did the study avoid inappropriate exclusions?
hedgedstates a possible cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
None of the sources cited for this claim could be matched to a paper, so there is nothing to check it against.
In the paper
“Because the accuracy of a test may depend on where it will be used in the diagnostic pathway, review authors are asked to describe patients in terms of setting, intended use of the index test, patient presentation, and previous testing (8,9).”
§ QUADAS-2: A Revised Tool for the Quality Assessment of Diagnostic Accuracy Studies > Phase 1: Review Question
What the sources say
- Not matchedcites [8]
The reference list we hold has no entry [8].
- Not matchedcites [9]
The reference list we hold has no entry [9].
hedgedstates a possible cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Not matched
In the paper
“Development of QUADAS-2 was based on the 4-stage approach proposed by Moher and colleagues (4): define the scope, review the evidence base, hold a face-to-face consensus meeting, and refine the tool through piloting.”
§ QUADAS-2: A Revised Tool for the Quality Assessment of Diagnostic Accuracy Studies > METHODS
What the sources say
- Not matchedcites [4]
The reference list we hold has no entry [4].
plainstates a cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: unclear — It is unclear whether the paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Not matched
None of the sources cited for this claim could be matched to a paper, so there is nothing to check it against.
In the paper
“Studies enrolling participants with known disease and a control group without the condition may similarly exaggerate diagnostic accuracy (7,11).”
§ QUADAS-2: A Revised Tool for the Quality Assessment of Diagnostic Accuracy Studies > Signaling question 2: Was a case-control design avoided? Signaling question 3: Did the study avoid inappropriate exclusions?
What the sources say
- Not matchedcites [7]
The reference list we hold has no entry [7].
- Not matchedcites [11]
The reference list we hold has no entry [11].
hedgedstates a possible cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Not matched
10 more claims
Create a free account to see all 40 claims and every source verdict.
- Probably not a substantial claim. 19
- It may state two separate claims as one. 16
- The quote only partly states this claim. 2
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“We assessed the study-level risk of bias with the QUADAS-2 tool”
In the citing paper
“We developed a revised risk-of-bias assessment tool to address these issues, incorporate advances in assessment of risk of bias used in other recently developed tools, 9 10 and integrate recent developments in estimation of intervention effects from randomised trials. 11”
From RoB 2: a revised tool for assessing risk of bias in randomised trials (2019) · cites this paper as [10]
In the citing paper
“Two reviewers independently assessed the quality of the included studies with the Quality Assessment of Diagnostic Accuracy Studies (Quadas-2) [33].”
From High-standard predictive equations for estimating body composition using bioelectrical impedance analysis: a systematic review (2024) · cites this paper as [33]
In the citing paper
“The quality of the selected studies was rigorously assessed using the Checklist for Artificial Intelligence in Medical Imaging (CLAIM) alongside the Quality Assessment of Diagnostic Accuracy Studies-2 (QUADAS-2).23,24”
From Artificial Intelligence Detection and Segmentation Models: A Systematic Review and Meta-Analysis of Brain Tumors in Magnetic Resonance Imaging (2024) · cites this paper as [24]
In the citing paper
“The methodological quality of each selected study was assessed according to the Quality Assessment of Diagnostic Accuracy Studies (QUADAS-2) checklist [15]”
From The diagnostic accuracy of digital, infrared and mercury-in-glass thermometers in measuring body temperature: a systematic review and network meta-analysis (2021) · cites this paper as [15]
20 more claims about this paper
Create a free account to see every claim other papers make about this one.
Citations
Cites
The Cochrane Collaboration's tool for assessing risk of bias in randomised trials
Higgins, J. P. T., Altman, D. G., Gotzsche, P. C., Juni, P., Moher, D., Oxman, A. D., Savovic, J., Schulz, K. F., Weeks, L., Sterne, J. A. C., et al. (2011) · BMJ · doi:10.1136/bmj.d5928 · Cited by 33,817
Self-citationWhiting, P., Rutjes, A. W., Reitsma, J. B., Bossuyt, P. M., & Kleijnen, J. (2003) · BMC Medical Research Methodology · doi:10.1186/1471-2288-3-25 · Cited by 3,592
Self-citationThe Hazards of Scoring the Quality of Clinical Trials for Meta-analysis
Jüni, P. (1999) · JAMA · doi:10.1001/jama.282.11.1054 · Cited by 1,981
Empirical evidence of design-related bias in studies of diagnostic tests.
Lijmer, J. G. (1999) · JAMA · doi:10.1001/jama.282.11.1061 · Cited by 1,861 · cited 2×
“Studies enrolling participants with known disease and a control group without the condition may similarly exaggerate diagnostic accuracy (7, 11).”
BackgroundGuidance for Developers of Health Research Reporting Guidelines
Moher, D., Schulz, K. F., Simera, I., & Altman, D. G. (2010) · PLoS Medicine · doi:10.1371/journal.pmed.1000217 · Cited by 1,437
Systematic Reviews of Diagnostic Test Accuracy
Leeflang, M. M. G., Deeks, J. J., Gatsonis, C., & Bossuyt, P. M. M. (2008) · Annals of Internal Medicine · doi:10.7326/0003-4819-149-12-200812160-00008 · Cited by 1,124
Self-citationSources of Variation and Bias in Studies of Diagnostic Accuracy: A Systematic Review
Whiting, P., Rutjes, A. W. S., Reitsma, J. B., Glas, A. S., Bossuyt, P. M. M., & Kleijnen, J. (2004) · Annals of Internal Medicine · doi:10.7326/0003-4819-140-3-200402030-00010 · Cited by 798 · cited 4×
“The third review was an update on sources of bias and variation in diagnostic accuracy studies that included 101 studies (7).”
BackgroundInfluentialSelf-citationEvaluation of QUADAS, a tool for the quality assessment of diagnostic accuracy studies
Whiting, P. F., Weswood, M. E., Rutjes, A. W., Reitsma, J. B., Bossuyt, P. N., & Kleijnen, J. (2006) · BMC Medical Research Methodology · doi:10.1186/1471-2288-6-9 · Cited by 769
Self-citationLeeflang, M. M. G., Moons, K. G. M., Reitsma, J. B., & Zwinderman, A. H. (2008) · Clinical Chemistry · doi:10.1373/clinchem.2007.096032 · Cited by 346 · cited 1×
“Test performance is likely to be poorer in an independent sample of patients in whom the same threshold is used (12).”
BackgroundSelf-citationNo role for quality scores in systematic reviews of diagnostic accuracy studies
Whiting, P., Harbord, R., & Kleijnen, J. (2005) · BMC Medical Research Methodology · doi:10.1186/1471-2288-5-19 · Cited by 337
Self-citation
Cited by
Items 13,701–13,800 of 14,770
Everybody Complains about Vasospasm but Nobody Does Anything about It
Macdonald, R. L. (2026) · Neurocritical Care · doi:10.1007/s12028-026-02511-5
“The quality was assessed using the Quality Assessment of Diagnostic Accuracy Studies (QUADAS-2), which is one of several methods for assessing diagnostic tests [9].”
Muchie, K. F., Tobian, F., Gaeddert, M., Denkinger, C. M., Wright, J. K., & Gupta‐Wright, A. (2026) · BMJ Open · doi:10.1136/bmjopen-2025-115230
Hierard, D., Padilla-Prieto, C., Arego, C., Nebot, A., Vallecillo, C., Guerriero, S., Orozco, R., & Alcázar, J. L. (2026) · Journal of Clinical Ultrasound · doi:10.1002/jcu.70248
Guamán, M. L. I., Ramírez, M. R. A., & Carreño, J. P. B. (2026) · Ibero Ciencias - Revista Científica y Académica · doi:10.63371/ic.v5.n2.a1004
“Para cada estudio incluido se extrajeron de forma sistemática los datos relacionados con el diseño metodológico, la población estudiada, el tamaño muestral, el tipo de algoritmo empleado, la tarea evaluada, el estándar de referencia y los principales indicadores de desempeño, y la calidad metodológica de los estudios…”
InfluentialChen, Z., Li, M., Tian, Z., & Wan, X.-H. (2026) · Journal of Ophthalmology · doi:10.1155/joph/8136183
Pedrosa, J. G. G., Pereira, F. J. L., Neto, A. L. C., Stropp, R. R., de Moura, G. P. R., de Melo, M. D. T., Pontes, S. L. D., & Félix, A. D. S. (2026) · ARQUIVOS BRASILEIROS DE CARDIOLOGIA - IMAGEM CARDIOVASCULAR · doi:10.36660/abcimg.20250082i
Pedrosa, J. G. G., Pereira, F. J. L., Neto, A. L. C., Stropp, R. R., de Moura, G. P. R., de Melo, M. D. T., Pontes, S. L. D., & Félix, A. D. S. (2026) · ARQUIVOS BRASILEIROS DE CARDIOLOGIA - IMAGEM CARDIOVASCULAR · doi:10.36660/abcimg.20250082
Prasad, A., Sharan, S., & Awati, A. (2026) · International Journal of Health Sciences and Research · doi:10.52403/ijhsr.20260419
Neto, M. P. L., LIMA, M. A. P. D., da Silva, C. G. L., Kerr, L. R. F. S., & Gurgel, R. Q. (2026) · BMJ Open · doi:10.1136/bmjopen-2025-115007
Duedahl, F. (2026) · British Journal of Cancer Research · doi:10.31488/bjcr.214
Wang, K., Abbas, A., Schemitsch, G. W., Raleigh, M. J., Lex, J. R., Felice, H., Nousiainen, M. T., Whyne, C., Ravi, B., & Koucheki, R. (2026) · Mayo Clinic Proceedings Digital Health · doi:10.1016/j.mcpdig.2026.100367
“14,15 This instrument evaluates methodological rigor across 4 domains: patient selection, index test, reference standard, and flow and timing.”
Designing and conducting systematic reviews and meta-analyses in ophthalmology
Keshtkar, A., & Ghasemi, M. (2026) · Medical Hypothesis Discovery & Innovation in Ophthalmology · doi:10.51329/mehdiophthal1541
Annecchiarico, M. M., Loiaco, G., Argenio, G., Varricchio, A., Rompianesi, G., & Cannella, R. (2026) · Abdominal Radiology · doi:10.1007/s00261-026-05532-y
“Comparative cohorts were appraised with QUADAS-2 [19 ], and case reports/series with the Murad et al. tool [20].”
Jiang, W., Huang, Y., Pang, J., Yang, S., & Chen, R. (2026) · European Journal of Surgical Oncology · doi:10.1016/j.ejso.2026.111808
Elsheikh, E. E. A., Ramadan, M. A., Abdelhalim, F. I., & Babiker, E. B. H. (2026) · Cureus · doi:10.7759/cureus.107774
“The methodological quality and risk of bias of the included studies were assessed using the QUADAS-2 (Quality Assessment of Diagnostic Accuracy Studies-2) tool [10].”
Zhang, H., Dromard, E., Tsang, K. C. H., Güemes, A., Guo, Z., Baldeweg, S. E., & Li, K. (2026) · medRxiv · doi:10.64898/2026.04.24.26351680 · Cited by 1
Agha, F. G., Al-Taai, N., & Ibrahim, A. (2026) · Discover Artificial Intelligence · doi:10.1007/s44163-026-01306-z
“Diagnostic and classification studies were assessed using QUA-DAS-2 [21], and prediction or decision-support models were evaluated using PROBAST [22].”
Neto, J. C., da Silva, V. M., & Lopes, M. C. M. S. (2026) · International Journal of Nursing Knowledge · doi:10.1177/20473087261443270
“…test; and 4-Patient fl ow and timing of index and reference tests) linked to the P-I-T components and includes questions regarding the level of concern reviewers have about the study ’ s accuracy in relation to the index test, reference standard, and participant selection (Whiting et al., 2011).”
Gou, Q., He, X., & Zhang, X. (2026) · World Journal of Surgical Oncology · doi:10.1186/s12957-026-04381-9
“The Quality Assessment of Diagnostic Accuracy Stud-ies-2 (QUADAS-2) tool will be applied to assess the risk of bias and clinical applicability of the included primary studies [15].”
Rasouli, M. A., Najafi, F., Ansari-Moghaddam, A., Nouri, B., Moradpour, F., Moradi, G., & Moradi, Y. (2026) · Health Science Reports · doi:10.1002/hsr2.72469
Mallmann, M. M., Pereira, F. L., Duarte, M. L., Andrade, A. M. M. D., Júnior, E. L., & Ramos, O. (2026) · Revista Científica Multidisciplinar Núcleo do Conhecimento · doi:10.32749/nucleodoconhecimento.com.br/nutrition/ultrasound-elastography
Șerban, R.-I., Isaic, A., Tarţa, C., Flaviu-Ionut, F., Ciprian, D., Motofelea, A. C., & Emanuel, D. A. (2026) · Diagnostics · doi:10.3390/diagnostics16091363
“The quality of the included studies was evaluated using the QUADAS-2 tool [23].”
Li, N., Zhou, Z., Yao, T., & Xu, X. (2026) · Nursing and Health Sciences · doi:10.1111/nhs.70344
“Two researchers evaluated the quality of the included studies using QUADAS-2 (Quality Assessment of Diagnostic Accuracy Studies-2) (Whiting et al. 2011), a diagnostic test system evaluation tool recommended by the Cochrane Collaboration.”
What is the Utility of Point-of-care Ultrasound for Diagnosing Retinal Detachment?
Jeffers, K., Keim, S. M., Long, B., Gottlieb, M. A., & Adhikari, S. R. (2026) · Journal of Emergency Medicine · doi:10.1016/j.jemermed.2026.04.023
Maesa, J. M., Dobrzynska, A., Rodríguez-López, R., & Blasco‐Amaro, J. A. (2026) · doi:10.52766/lwfl8076
Alsheikh, R. A., Assami, D., Nasrallah, D., Arabi, A., Hamdan, A., Elhadary, M. R., Elmakaty, I., & Malki, M. I. (2026) · Cancers · doi:10.3390/cancers18091437
“Included diagnostic studies were evaluated using the Quality Assessment of Diagnostic Accuracy Studies-2 (QUADAS-2) scale [25].”
Jain, A., Sen, S., Singh, M., Abbas, F., Vashishtha, G. K., Agarwal, A., & Kumar, S. (2026) · TNOA Journal of Ophthalmic Science and Research · doi:10.4103/tjosr.tjosr_23_26
Rehman, A., Awais, M., Baloch, N. U.-A., LEGHARI, M. O., Ahmad, A., & Javed, H. (2026) · Medical Sciences · doi:10.3390/medsci14020231
Zhang¹, S., & Zhang¹, L. (2026) · Research Square · doi:10.21203/rs.3.rs-9579591/v1
Gebril, N. M., Elettreby, A. M., Younis, A. H., Moawad, M. H. E. D., Hafez, A. M., Elsayed, T. G., Abdelrahman, K. M., & El-Kot, S. M. (2026) · Molecular Neurobiology · doi:10.1007/s12035-026-05864-2 · Cited by 1
“The methodological quality of included studies was assessed using the Quality Assessment of Diagnostic Accuracy Studies (QUADAS-2) tool [17].”
Ryan, M. E., Milinis, K., Ahamed, M., Sidat, F., & Fleming, J. C. (2026) · Otolaryngology · doi:10.1002/ohn.70251
Mohammed, H. M. A., Mohamed, H., Fofana, M., Jawaid, S., Hersi, M., Alwani, O., Nair, R., & Sagar, J. (2026) · Cancers · doi:10.3390/cancers18091440
“Quality Assessment of Diagnostic Accuracy Studies (QUADAS-2) was used for the assessment of risk of bias and applicability [56].”
Simhadri, H. (2026) · American journal of student research. · doi:10.70251/hyjr2348.42533547
Primary Care Screening and Management of Hearing Loss in Older Adults: A Systematic Review
Almutairi, L., Ayoub, A. Y., Al-Nahari, Y. Y., Alameer, H. M., Alqesair, M. H., Alghamdi, A. S., Alalawi, H. A., Alhajji, R. K., Alfaya, R. F., & Mawkili, M. H. (2026) · Cureus · doi:10.7759/cureus.108230
“Diagnostic accuracy studies were evaluated using the Quality Assessment of Diagnostic Accuracy Studies 2 (QUADAS-2) tool [15].”
Combined Striatal Dopaminergic and Cardiac Sympathetic Imaging in Parkinson’s Disease
Versweyveld, L., Vanderlinden, G., Vandenberghe, W., Delva, A., & Laere, K. V. (2026) · Brain Sciences · doi:10.3390/brainsci16050484
Babbitt, K., Funnell, E. L., Martin-Key, N. A., Barker, E., & Bahn, S. (2026) · doi:10.2196/preprints.99682
Mohammed, A., Mohammed, A. M., Elshiekh, A., TalbAllah, S. M., Mohamed, W. M. H., Mohammedallayla, I. D., Ali, M., & Elsamani, E. A. E. M. (2026) · Cureus · doi:10.7759/cureus.108178
“The methodological quality and risk of bias of the included studies were assessed using the Quality Assessment of Diagnostic Accuracy Studies (QUADAS-2) tool [8].”
Photon-counting CT in gastrointestinal malignancies: a scoping review
Spoto, F., Robertis, R. D., Monterubbiano, L., Sala, G., Demozzi, E., Cicciò, C., Longo, C., Cardobi, N., Mascarin, B., Foti, G., et al. (2026) · European Journal of Radiology · doi:10.1016/j.ejrad.2026.112905
Zhao, Y., Yang, G., Yang, M., Deng, X. M., Dai, Z., Dai, P., Wang, K., Liao, S., Jiang, L., Dai, J., et al. (2026) · International Journal of Surgery · doi:10.1097/js9.0000000000005144
“…study adheres to the PRISMA-DTA (Preferred Reporting Items for Systematic Reviews and Meta-Analyses of Diagnostic Test Accuracy) guidelines [ 21 ] and employs the revised QUADAS-2 (Quality Assessment of Diagnostic Accuracy Studies 2) criteria to rigorously assess diagnostic test studies [ 22 ] .”
InfluentialGlobal Research Progress on D-Dimer in Pregnancy
陶, 杉. (2026) · Advances in Clinical Medicine · doi:10.12677/acm.2026.1651799
Darkwa, E. K., Cross, J. H., Adjei, P., Newton, C. R. J. C., Sen, A., Akpalu, A., Sander, J. W. A. S., & Danso‐Appiah, A. (2026) · BMJ Open · doi:10.1136/bmjopen-2026-116684
Hosseini, I., Northey, J. M., D'Cunha, N. M., Rojas, R. F., Shrestha, A., & Ghahramani, M. (2026) · Frontiers in Digital Health · doi:10.3389/fdgth.2026.1728588
“The NOS was selected because the included studies were primarily observational (cross-sectional, case-control, or cohort designs) [24, 25].”
Schilder, J. C. M., Hoonhorst, M. H. J., de Vries, M. R., & Kwakkel, G. (2026) · Frontiers in Neurology · doi:10.3389/fneur.2026.1788829
“…recently developed, is designed to evaluate observational prognostic studies and integrate elements from the Quality Assessment of Diagnostic Accuracy Studies 2 (QUADAS-2) (29), the Quality in Prognosis Studies tool (QUIPS) (30), and the Prediction model Risk of Bias Assessment Tool (PROBAST) (31).”
Ahmadzadeh, A. M., Ashoobi, M. A., Lomer, N. B., Vatanparast, M., Gheiji, B., Elyassirad, D., & Faghani, S. (2026) · Clinical Imaging · doi:10.1016/j.clinimag.2026.110817
[18F]FDG PET radiomics and its application in lung cancer radiotherapy: a systematic review
Abedi‐Firouzjah, R., Mahdavi, S. R., Ay, M. R., Ghaffari, H., Faghani-Eskandarkolaei, P., & Abbaspour, S. (2026) · Journal of Radioanalytical and Nuclear Chemistry · doi:10.1007/s10967-026-10916-x
“Risk of bias (ROB) was assessed for all included studies using a tool based on the QUADAS-2 domains (Patient Selection, Index Test, Reference Standard, Flow and Timing) [28].”
Hill, O. S., & Jee, E. Y. (2026) · Journal of Clinical Orthopaedics and Trauma · doi:10.1016/j.jcot.2026.103469
Diagnostic Accuracy of Multiparametric MRI for Prostate Cancer Detection: A Meta-Analysis
Yousaf, S., Farooq, S. M. Y., Moazzam, M., Asif, M. F., Niazi, Y., & Bilal, S. (2026) · SN Comprehensive Clinical Medicine · doi:10.1007/s42399-026-02409-5
Buczinski, S., Gomes, V., Vergnes, G., Poirier, M. C., Owusu-Afryie, S., Berman, J., & Dendukuri, N. (2026) · Journal of Dairy Science · doi:10.3168/jds.2025-28206
Chang, C. Y. G., Foran, A. M., & Cheung, M. W. ‐. (2026) · Neuropsychology Review · doi:10.1007/s11065-026-09718-5
Palmiero, H. D. O. M., & Figueiredo, E. G. (2026) · Journal of Emergency Medicine · doi:10.1016/j.jemermed.2026.05.001
Awachat, A., & Hazare, A. (2026) · Cureus · doi:10.7759/cureus.108572
“The methodological quality of the included studies and concerns regarding applicability were independently assessed by two reviewers using the Quality Assessment of Diagnostic Accuracy Studies-2 (QUADAS-2) tool [20].”
Wei, Y., Gu, M., Su, Y., Xi, J., Ren, Y., & Hu, Z. (2026) · Malaysian Journal of Medical Sciences · doi:10.21315/mjms-11-2025-818
“The methodological quality of the included studies was assessed using the Quality Assessment of Diagnostic Accuracy Studies 2 (QUADAS-2) tool, which evaluates four domains: patient selection, index test, reference standard, and flow and timing (12).”
Awan, B., Elsaigh, M., Gamal, M. H., Elbahnasawy, S. E., & Badee, M. (2026) · Cureus · doi:10.7759/cureus.108662
“The methodological quality of the studies included in this review was assessed using the Quality Assessment of Diagnostic Accuracy Studies-2 (QUADAS-2) tool [18], which is a validated framework for evaluating diagnostic accuracy studies.”
Stability of whole blood samples at different temperatures: a systematic review
Nygaard, R. H., Justesen, J. F., Wigh, I. M. N., Nybo, M., & Andersen, E. S. (2026) · Diagnosis · doi:10.1515/dx-2025-0180
“…appraisal tool for sample stability studies could be identi fi ed, a quality assessment tool (Supplementary Material 2) inspired by QUADAS-2 [8] and the JBI Checklist for Diagnostic Test Accuracy Studies [9] was developed by the authors prior to extraction and fi lled out during the…”
Molecular and statistical weaknesses of the p-tau217/Aβ1−42 plasma ratio for alzheimer’s diagnosis
Griñán‐Ferré, C., Pallàs, M., & Franco, R. (2026) · Journal of Molecular Medicine · doi:10.1007/s00109-026-02676-8 · Cited by 2
Beltrán-Gómez, Y. T., Prieto-Bohórquez, S.-E., & Rojas, J. G. (2026) · Respuestas · doi:10.22463/0122820x.5743
Yin, Y., Ma, T., Zhang, X., Chi, X., Zhu, K., & Ling, J. (2026) · Frontiers in Immunology · doi:10.3389/fimmu.2026.1812710
Yang, P., Fan, F., Yang, T., & Wang, R. (2026) · Abdominal Radiology · doi:10.1007/s00261-026-05501-5
“Two reviewers independently conducted quality assess - ment using the Quality Assessment of Diagnostic Accuracy Studies (QUADAS)-2 [ 13] in Review Manager 5.2 soft - ware.”
InfluentialValsamidis, T. N., Mohr, K. M., & Hjortdal, J. (2026) · Contact Lens and Anterior Eye · doi:10.1016/j.clae.2026.102661
Parrón-Carreño, T., Soriano, B. J. N., Lozano‐Paniagua, D., Murillo-Cancho, A. F., & Cañadas, D. C. (2026) · Clinica Chimica Acta · doi:10.1016/j.cca.2026.121071
Sanchez-Guillen, J., Ita-Balta, Y., & Sam, M. C. M. (2026) · Indian Journal of Tuberculosis · doi:10.1016/j.ijtb.2026.05.001
Moradi-Joo, E., Behbahani, S. M. S., Lagha, M. E., Asl, E. M., Baghaei, S., Mahmoudabad, Y. S., Hasanian, A., Davarpanah, M., & Fakhri, A. (2026) · Jundishapur Journal of Chronic Disease Care · doi:10.5812/jjcdc-167826
The Role of Artificial Intelligence in Facial Reanimation Outcomes—A Systematic Review
See, A. S. Y., Wong, R. S. H., Yap, Y. T., & Ng, L. S. (2026) · Facial Plastic Surgery & Aesthetic Medicine · doi:10.1177/26893614261446085
Szőke, E., Szántó, I., Turan, C., Szabó, B., Papp, M., Horváth, G., Zubek, L., Hegyi, P., Molnár, Z., & Lovas, A. (2026) · PLoS ONE · doi:10.1371/journal.pone.0349092
Rosman, W., Felinda, S. O., Hartono, U., Amfotis, P., Muhammad, A., Antonius, Heriyansyah, Oktavia, D. M., Ansanai, M. D. R., & Marhayuni, Y. (2026) · F1000Research · doi:10.12688/f1000research.182642.1 · Cited by 1
Srour, A., Omar, M., Barash, Y., Litmanovich, D., Srour, M., Klang, E., & Gorenshtein, A. (2026) · Journal of the American College of Radiology · doi:10.21203/rs.3.rs-9705085/v1
Mirghaderi, P., Eshraghi, N., Lee, H., Kim, H. S., Haseli, S., Azhideh, A., Park, C., Lee, I. S., Thurlow, P. C., & Chalian, M. (2026) · Korean Journal of Radiology · doi:10.3348/kjr.2025.1769
“The methodological quality and risk of bias of the included studies were assessed using the Quality Assessment of Diagnostic Accuracy Studies-2 (QUADAS-2) tool, which evaluates four domains: patient selection, index test, reference standard, and flow and timing [26].”
Thomas, M. S., Shinde, S., Chaudhary, N. S., & Chaudhary, S. (2026) · Cureus · doi:10.7759/cureus.108817
“Diagnostic validity studies were evaluated using the Quality Assessment of Diagnostic Accuracy Studies (QUADAS-2) tool [10], while observational cohorts were assessed using the Newcastle-Ottawa Scale (NOS) [11,12].”
Mehne, Z. S., Honarjou, E., & Khamoushi, M. (2026) · International Journal of Infectious Diseases · doi:10.1016/j.ijid.2026.108769
Explainable Artificial Intelligence in Speech-Based Cognitive Decline Detection: A Systematic Review
Shankar, R., Bundele, A., & Mukhopadhyay, A. (2026) · Communications in computer and information science · doi:10.1007/978-3-032-21514-7_5
Stuani, R., Zolesi, F., Piano, A., & Filardo, G. (2026) · Journal of Cartilage & Joint Preservation · doi:10.1016/j.jcjp.2026.100302
Jin, Y., Xu, J., Yue, H., Huang, Y., Ma, W., Fan, X.-D., Wang, H., Xu, L., & Wang, J. (2026) · Journal of Translational Medicine · doi:10.1186/s12967-026-08214-x
“The Quality Assessment of Diagnostic Accuracy Stud-ies-2 (QUADAS-2) tool was used to evaluate the quality of the primary studies [14].”
Yam, K.-M., Lim, C. Y. J., Gao, E. Y., Koh, J. H., Tan, N. K. W., Ng, A. C. W., Leong, Z. H., Phua, C. Q., Ong, T. H., Leow, L. C., et al. (2026) · Journal of Medical Internet Research · doi:10.2196/80349
“The quality assessment of included studies was assessed by 2 blinded, independent reviewers (KJMY and CYJL), using the Quality Assessment of Diagnostic Accuracy Studies-2 (QUADAS-2) tool to evaluate the risk of bias and applicability of diagnostic accuracy studies [28].”
Clifford, A. H., Thai, J., Yip, A., Homik, J., Vandermeer, B., Kung, J. Y., & Tervaert, J. W. C. (2026) · The Journal of Rheumatology · doi:10.3899/jrheum.2026-0050
Detloff, L., Miyashita, S., Rose-Malkamaki, M. J., Jawad, Z. N., Skvarce, J., AYOUB, N., Schleicher, M. C., Tonelli, A. R., & Siuba, M. (2026) · Journal of Cardiac Failure - Intersections · doi:10.1016/j.yjcafi.2026.04.010 · Cited by 1
Ong, P., Chua, V. H., Rebosa, L. M. F., Guzman, B. M. T. D., Bacorro, W., & Yu, K. K. (2026) · Brachytherapy · doi:10.1016/j.brachy.2026.03.015
Sánchez, J. I. A., Caicedo-Ruiz, J. D., Torres-Martínez, M. J., & Fernández, J. J. D. (2026) · BMC Anesthesiology · doi:10.1186/s12871-026-03910-z
“When reported, respiratory system compliance varied substantially across cohorts [16, 17, 20, 23].”
Casarini, C., Magnini, A., Pisano, M., Landini, N., Casto, A. L., & Nardi, C. (2026) · Dentomaxillofacial Radiology · doi:10.1093/dmfr/twag027
Yu, G., Du, K., Shen, Y., Ling, Y., & Zhong, F. (2026) · BMJ Open · doi:10.1136/bmjopen-2025-116013
“17 This instrument evaluates risk of bias across four domains: patient selection, index test, reference standard and flow/timing.”
Use of Artificial Intelligence for the Early Detection and Prediction of Alzheimer’s Disease
Khangsar, L. T., & Boileau, A. J. (2026) · Cureus · doi:10.7759/cureus.109138
“The Quality Assessment of Diagnostic Accuracy Studies 2 (QUADAS-2) tool [18] was selected to evaluate the risk of bias because the included studies focused on diagnostic accuracy and prediction modeling rather than therapeutic interventions.”
Hand Trauma Case-Identification Using Administrative Data: A Systematic Review
Wong, C. R., Rosebush, C. E., & Baltzer, H. L. (2026) · Journal of Wrist Surgery · doi:10.1055/a-2868-4092
Chandrasekaran, N., Ramachandran, A., Elanchezhian, A., L, R. R., & Raja, H. (2026) · Journal of Education Technology in Health Sciences · doi:10.18231/j.jeths.14984.1776843018
Messner, L., Lukacs, S., Flaig, M. J., Hartmann, D., & Kendziora, B. (2026) · Diagnostics · doi:10.3390/diagnostics16101539
“The methodological quality and applicability of all included studies were assessed using the Quality Assessment of Diagnostic Accuracy Studies (QUADAS-2) tool [18].”
Nimmagadda, Y., & Makkena, H. (2026) · Research Square · doi:10.21203/rs.3.rs-9743049/v1
Petzoldt, M., Wünsch, V. A., Grün, C., Sasu, P. B., & Köhl, V. (2026) · British Journal of Anaesthesia · doi:10.1016/j.bja.2026.03.083
Rizzo, G. E. M., Infantino, G., Marchegiani, G., Machicado, J. D., Chiaro, M. D., Tarantino, I., Rossi, G., Arcidiacono, P. G., Vanella, G., Guilabert, L., et al. (2026) · World Journal of Clinical Oncology · doi:10.5306/wjco.v17.i5.120600
(2026) · Instituto Aragonés de Ciencias de la Salud (IACS) eBooks · doi:10.46994/ets_49
Comment on “Ultrasonography or Radiography for Suspected Pediatric Talocalcaneal Coalition”
Cheema, M. R. S., & Arfeen, S. (2026) · Journal of Pediatric Orthopaedics · doi:10.1097/bpo.0000000000003334
House, E., McMaster, C., Lister, N., Jardine, I. R., Lorien, S., Seidler, A., & Jebeile, H. (2026) · International Journal of Eating Disorders · doi:10.1002/eat.70132
“If a study was judged to have “high” or “unclear” concerns regarding applicability in any of the three domains, it was deemed to have “concerns regarding applicability” (Whiting et al. 2011).”
Genetic Fingerprint of Klebsiella pneumoniae Virulence: A Systematic Review
Aldana-Ortega, C. A., Pérez-Villadiego, A. J., Monterrosa-Taborda, Y., Angulo-Ortíz, A., & Martínez, O. I. C. (2026) · Pathogens · doi:10.3390/pathogens15050556
“EMMO-Vir was developed based on established methodological frameworks, including STROBE [15], STARD [16], QUADAS-2 [17], and JBI criteria [18], and was refined through an internal iterative review process to improve item clarity and applicability before full assessment.”
Artificial intelligence for detection and staging of Alzheimer’s disease using retinal images
Panjwani, M., Holmes, J. M., Liu, S.-H., Lee, E., Rapcsak, S. Z., Harris, A., & Kozak, I. (2026) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd016358 · Cited by 1
Deng, F., Wan, X., & Tang, Y. D. (2026) · Journal of Clinical Nursing · doi:10.1111/jocn.70364
John, J. D., Henna, F., Waseem, F., Hassan, M. A., Bacha, Z., Mukhlis, M., Mohammed, B. K., Cheema, S., & Shah, K. (2026) · medRxiv · doi:10.64898/2026.05.15.26353184
Unblinded Operator Bias in Multimodal Prostate Ultrasound: The Case for Independent Validation
Lu, Y., & Ma, C. (2026) · Journal of Ultrasound in Medicine · doi:10.1002/jum.70304
Uy, H., Nollora, L., Villanueva, M., Leon, J. M. D., FlorCruz, N. V., & Bromeo, A. J. (2026) · PLOS Global Public Health · doi:10.1371/journal.pgph.0006327
“The risk of bias and applicability on the (a) patient selection, (b) index test, (c) reference standard, and (d) flow and timing of the included studies were independently assessed by two review authors [HU and MV] using the Quality Assessment of Diagnostic Accuracy Studies (QUADAS)-2 tool [18].”
Aplicabilidad del cuestionario HEMSTOP como herramienta de cribado preoperatorio
Cardozo-Panoff, M., Mariño, R. B., & Suñé, A. B. (2026) · Revista Española de Anestesiología y Reanimación · doi:10.1016/j.redar.2026.502143
Fuller, G. W., Baird, J., Miller, J., Pilbery, R., Herbert, E., Keating, S., Callaghan, T., Pollard, D. J., Pandor, A., Essat, M., et al. (2026) · Health Technology Assessment · doi:10.3310/alpe8857
Feltz-Cornelis, C. M. V. D. (2026) · White Rose Research Online (University of Leeds, The University of Sheffield, University of York)
Zhou, R., Yang, H., Herth, F. J., Zhang, X., & Kong, D. (2026) · Clinical & Translational Oncology · doi:10.1007/s12094-026-04420-7
“Two reviewers (ZRJ and YHZ) independently assessed study quality using the QUADAS-2 tool, evaluating patient selection, index tests, reference standards, and study flow and timing [17].”
Metadata
- Authors
- Whiting, P. F., Rutjes, A. W. S., Westwood, M. E., Mallett, S., Deeks, J. J., Reitsma, J. B., Leeflang, M. M. G., Sterne, J. A. C., Bossuyt, P. M. M., & the QUADAS-2 Group*
- Affiliations
- University of Bern (CH)
- Corresponding author
- Whiting, Penny F.
- ORCID
- Venue
- Annals of Internal Medicine
- Publisher
- American College of Physicians
- Published
- 2011-10-18
- Volume
- 155
- Issue
- 8
- Pages
- 529-536
- ISSN
- 0003-4819 (ISSN-L)
- 1539-3704
- OpenAlex
- W2107638293
- Semantic Scholar
- 8a5d0b5a9271ea14bcb8479bc32d3844a80655b9
- Cited by
- 14,199
- References
- 18
- Citations by year
- 2026: 1484 · 2025: 1569 · 2024: 1524 · 2023: 1305 · 2022: 1420 · 2021: 1514 · 2020: 1245 · 2019: 955 · 2018: 767 · 2017: 637 · 2016: 580 · 2015: 528 · 2014: 363 · 2013: 217 · 2012: 75
- FWCI
- 224.36
- Type
- journal article
- Language
- en
- Open access
- green
- hdl.handle.net
- Licence
- cc-by
- www.acpjournals.org/journal/aim/text-and-data-mining (tdm)
- Locations
- Annals of Internal Medicine (publishedVersion)
- PubMed (publishedVersion)
- Pure Amsterdam UMC (publishedVersion)
- Data Archiving and Networked Services (DANS) (submittedVersion)
- Florence Research (University of Florence) (submittedVersion)
- IRIS UNIMORE (University of Modena and Reggio Emilia) (submittedVersion, cc-by)
- University of Birmingham Research Portal (University of Birmingham) (submittedVersion)
- Bristol Research (University of Bristol) (submittedVersion)
- Funders
- Cancer Research UK
- Topics
- Social Sciences › Decision Sciences › Statistics, Probability and Uncertainty › Meta-analysis and systematic reviews
- Physical Sciences › Mathematics › Statistics and Probability › Statistical Methods in Epidemiology
- Health Sciences › Medicine › Public Health, Environmental and Occupational Health › Clinical practice guidelines implementation
- Keywords
- QUADAS-2, diagnostic accuracy studies, quality assessment, risk of bias, applicability, patient selection, index tests, reference materials, flowcharts, systematic reviews
- MeSH terms
- Diagnosis, Humans, Quality Control, Surveys and Questionnaires, Reference Standards, Review Literature as Topic, Time Factors, Bias, Patient Selection, Evidence-Based Medicine
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
A language model drew the claims from the paper on 2026-11-23, under version 3 of the claim definition (model deepseek-v4.1-flash, prompt extract-v3).
A second model labelled each claim on 2026-11-23 (model jev-1.13-20260917, definition revision gold-guideline-v0.2).
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.