QUADAS-2: A Revised Tool for the Quality Assessment of Diagnostic Accuracy Studies
Open accessThe DOI matches its Crossref record; 18 of the 18 references it cites were found in a registry or an index; none of the 21 sources its claims cite is checked for support yet.
Abstract
In 2003, the QUADAS tool for systematic reviews of diagnostic accuracy studies was developed. Experience, anecdotal reports, and feedback suggested areas for improvement; therefore, QUADAS-2 was developed. This tool comprises 4 domains: patient selection, index test, reference standard, and flow and timing. Each domain is assessed in terms of risk of bias, and the first 3 domains are also assessed in terms of concerns regarding applicability. Signalling questions are included to help judge risk of bias. The QUADAS-2 tool is applied in 4 phases: summarize the review question, tailor the tool and produce review-specific guidance, construct a flow diagram for the primary study, and judge bias and applicability. This tool will allow for more transparent rating of bias and applicability of primary diagnostic accuracy studies.
Overview
CoChat Summary
TL;DR
QUADAS-2 is a revised tool for assessing risk of bias and applicability in diagnostic accuracy studies, developed through a 4-stage evidence-based consensus process. It replaces the original QUADAS “yes/no/unclear” quality rating with domain-level judgments of low, high, or unclear risk of bias and concerns about applicability.
Key findings
- QUADAS-2 separates “quality” into risk of bias and concerns regarding applicability, defining quality as the degree to which diagnostic accuracy estimates avoided bias and the extent to which primary studies are applicable to the review question.
- The tool has 4 key domains—patient selection, index test, reference standard, and flow and timing—with the first 3 also assessed for applicability; it is completed in 4 phases and uses signaling questions to help judge risk of bias.
- Development drew on 4 reviews: 54 diagnostic accuracy reviews published between 2007 and 2009, structured feedback from 64 systematic reviewers who had used QUADAS, 101 studies on sources of bias and variation, and 8 studies evaluating QUADAS; a 1-day consensus meeting had 24 attendees, and piloting occurred in 5 reviews.
- Interrater reliability varied considerably, with better agreement on applicability than on risk of bias; all participants preferred QUADAS-2 to the original tool, but the authors could not currently include criteria for studies comparing multiple index tests because the evidence base was insufficient.
Methods
- Tool development followed Moher and colleagues’ 4-stage approach: define the scope, review the evidence base, hold a face-to-face consensus meeting, and refine through piloting.
- A steering group of 9 experts set the scope; the consensus meeting was held on 21 September 2010 in Birmingham, United Kingdom, with 24 attendees who split into groups of 4 to 6 participants; multiple rounds of piloting used online questionnaires and other feedback, including pairs of reviewers piloting QUADAS-2 in 5 reviews.
- No primary statistical analysis was reported; the work synthesized evidence reviews, consensus decisions, and pilot feedback to produce and refine the tool.
Limitations
- Stated: the authors decided they cannot currently include criteria for assessing studies that compare multiple index tests within QUADAS-2 because of the limited evidence base on risk of bias and sources of variation in such studies, and they plan future work on this topic.
- Stated: piloting showed poor interrater reliability and problems applying the domain on comparative accuracy studies; interrater reliability varied considerably overall, with better agreement on applicability than on risk of bias.
- Evident from the text: full details of the 4 evidence reviews were to be published separately, and the main text reports no quantitative reliability estimates, referring instead to an Appendix Table.
Model-written summary. Check it against the paper before relying on it.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
0 Valid · 0 Not valid · 16 Not checked · 24 Own results and interpretations
In the paper
“In a review on anti-cyclic citrullinated peptide antibodies for diagnosing rheumatoid arthritis (10), we found that some studies enrolled consecutive participants with confirmed diagnoses. In these studies, testing for anticyclic citrullinated peptide antibody showed greater sensitivity than in studies that included patients with suspected disease but an unconfirmed diagnosis (that is, difficult-t”
§ QUADAS-2: A Revised Tool for the Quality Assessment of Diagnostic Accuracy Studies > Signaling question 2: Was a case-control design avoided? Signaling question 3: Did the study avoid inappropriate exclusions?
What the sources say
- Not matchedcites [10]
The reference list we hold has no entry [10].
plainstates an association- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Not matched
A statement the paper makes itself — it cites no source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“Studies that make inappropriate exclusions (for example, not including”
§ QUADAS-2: A Revised Tool for the Quality Assessment of Diagnostic Accuracy Studies > Signaling question 2: Was a case-control design avoided? Signaling question 3: Did the study avoid inappropriate exclusions?
hedgedstates a possible cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
None of the sources cited for this claim could be matched to a paper, so there is nothing to check it against.
In the paper
“Because the accuracy of a test may depend on where it will be used in the diagnostic pathway, review authors are asked to describe patients in terms of setting, intended use of the index test, patient presentation, and previous testing (8,9).”
§ QUADAS-2: A Revised Tool for the Quality Assessment of Diagnostic Accuracy Studies > Phase 1: Review Question
What the sources say
- Not matchedcites [8]
The reference list we hold has no entry [8].
- Not matchedcites [9]
The reference list we hold has no entry [9].
hedgedstates a possible cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Not matched
In the paper
“Development of QUADAS-2 was based on the 4-stage approach proposed by Moher and colleagues (4): define the scope, review the evidence base, hold a face-to-face consensus meeting, and refine the tool through piloting.”
§ QUADAS-2: A Revised Tool for the Quality Assessment of Diagnostic Accuracy Studies > METHODS
What the sources say
- Not matchedcites [4]
The reference list we hold has no entry [4].
plainstates a cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: unclear — It is unclear whether the paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Not matched
None of the sources cited for this claim could be matched to a paper, so there is nothing to check it against.
In the paper
“Studies enrolling participants with known disease and a control group without the condition may similarly exaggerate diagnostic accuracy (7,11).”
§ QUADAS-2: A Revised Tool for the Quality Assessment of Diagnostic Accuracy Studies > Signaling question 2: Was a case-control design avoided? Signaling question 3: Did the study avoid inappropriate exclusions?
What the sources say
- Not matchedcites [7]
The reference list we hold has no entry [7].
- Not matchedcites [11]
The reference list we hold has no entry [11].
hedgedstates a possible cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Not matched
10 more claims
Create a free account to see all 40 claims and every source verdict.
- Probably not a substantial claim. 19
- It may state two separate claims as one. 16
- The quote only partly states this claim. 2
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“We assessed the study-level risk of bias with the QUADAS-2 tool”
In the citing paper
“We developed a revised risk-of-bias assessment tool to address these issues, incorporate advances in assessment of risk of bias used in other recently developed tools, 9 10 and integrate recent developments in estimation of intervention effects from randomised trials. 11”
From RoB 2: a revised tool for assessing risk of bias in randomised trials (2019) · cites this paper as [10]
In the citing paper
“Two reviewers independently assessed the quality of the included studies with the Quality Assessment of Diagnostic Accuracy Studies (Quadas-2) [33].”
From High-standard predictive equations for estimating body composition using bioelectrical impedance analysis: a systematic review (2024) · cites this paper as [33]
In the citing paper
“The quality of the selected studies was rigorously assessed using the Checklist for Artificial Intelligence in Medical Imaging (CLAIM) alongside the Quality Assessment of Diagnostic Accuracy Studies-2 (QUADAS-2).23,24”
From Artificial Intelligence Detection and Segmentation Models: A Systematic Review and Meta-Analysis of Brain Tumors in Magnetic Resonance Imaging (2024) · cites this paper as [24]
In the citing paper
“The methodological quality of each selected study was assessed according to the Quality Assessment of Diagnostic Accuracy Studies (QUADAS-2) checklist [15]”
From The diagnostic accuracy of digital, infrared and mercury-in-glass thermometers in measuring body temperature: a systematic review and network meta-analysis (2021) · cites this paper as [15]
20 more claims about this paper
Create a free account to see every claim other papers make about this one.
Citations
Cites
The Cochrane Collaboration's tool for assessing risk of bias in randomised trials
Higgins, J. P. T., Altman, D. G., Gotzsche, P. C., Juni, P., Moher, D., Oxman, A. D., Savovic, J., Schulz, K. F., Weeks, L., Sterne, J. A. C., et al. (2011) · BMJ · doi:10.1136/bmj.d5928 · Cited by 33,817
Self-citationWhiting, P., Rutjes, A. W., Reitsma, J. B., Bossuyt, P. M., & Kleijnen, J. (2003) · BMC Medical Research Methodology · doi:10.1186/1471-2288-3-25 · Cited by 3,592
Self-citationThe Hazards of Scoring the Quality of Clinical Trials for Meta-analysis
Jüni, P. (1999) · JAMA · doi:10.1001/jama.282.11.1054 · Cited by 1,981
Empirical evidence of design-related bias in studies of diagnostic tests.
Lijmer, J. G. (1999) · JAMA · doi:10.1001/jama.282.11.1061 · Cited by 1,861 · cited 2×
“Studies enrolling participants with known disease and a control group without the condition may similarly exaggerate diagnostic accuracy (7, 11).”
BackgroundGuidance for Developers of Health Research Reporting Guidelines
Moher, D., Schulz, K. F., Simera, I., & Altman, D. G. (2010) · PLoS Medicine · doi:10.1371/journal.pmed.1000217 · Cited by 1,437
Systematic Reviews of Diagnostic Test Accuracy
Leeflang, M. M. G., Deeks, J. J., Gatsonis, C., & Bossuyt, P. M. M. (2008) · Annals of Internal Medicine · doi:10.7326/0003-4819-149-12-200812160-00008 · Cited by 1,124
Self-citationSources of Variation and Bias in Studies of Diagnostic Accuracy: A Systematic Review
Whiting, P., Rutjes, A. W. S., Reitsma, J. B., Glas, A. S., Bossuyt, P. M. M., & Kleijnen, J. (2004) · Annals of Internal Medicine · doi:10.7326/0003-4819-140-3-200402030-00010 · Cited by 798 · cited 4×
“The third review was an update on sources of bias and variation in diagnostic accuracy studies that included 101 studies (7).”
BackgroundInfluentialSelf-citationEvaluation of QUADAS, a tool for the quality assessment of diagnostic accuracy studies
Whiting, P. F., Weswood, M. E., Rutjes, A. W., Reitsma, J. B., Bossuyt, P. N., & Kleijnen, J. (2006) · BMC Medical Research Methodology · doi:10.1186/1471-2288-6-9 · Cited by 769
Self-citationLeeflang, M. M. G., Moons, K. G. M., Reitsma, J. B., & Zwinderman, A. H. (2008) · Clinical Chemistry · doi:10.1373/clinchem.2007.096032 · Cited by 346 · cited 1×
“Test performance is likely to be poorer in an independent sample of patients in whom the same threshold is used (12).”
BackgroundSelf-citationNo role for quality scores in systematic reviews of diagnostic accuracy studies
Whiting, P., Harbord, R., & Kleijnen, J. (2005) · BMC Medical Research Methodology · doi:10.1186/1471-2288-5-19 · Cited by 337
Self-citation
Cited by
Items 1,301–1,400 of 14,770
Datta, S., Shah, L., Gilman, R. H., & Evans, C. A. (2017) · The Lancet Global Health · doi:10.1016/s2214-109x(17)30201-2 · Cited by 107
Transabdominal ultrasound and endoscopic ultrasound for diagnosis of gallbladder polyps
Wennmacker, S. Z., Lamberts, M. P., Martino, M. D., Drenth, J. P. H., Gurusamy, K. S., & van Laarhoven, C. J. H. M. (2018) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd012233.pub2 · Cited by 109
Kang, S. K., Zhang, A. Y., Pandharipande, P. V., Chandarana, H., Braithwaite, R. S., & Littenberg, B. (2015) · American Journal of Roentgenology · doi:10.2214/ajr.14.13930 · Cited by 93
Woodford, R., Spittal, M. J., Milner, A., McGill, K., Kapur, N., Pirkis, J., Mitchell, A., & Carter, G. (2019) · Suicide and Life-Threatening Behavior · doi:10.1111/sltb.12395 · Cited by 92
Effectiveness of diagnosing pulpitis: A systematic review
Donnermeyer, D., Dammaschke, T., Lipski, M., & Schäfer, E. (2023) · International Endodontic Journal · doi:10.1111/iej.13762 · Cited by 92
Sood, R., Gracie, D. J., Law, G. R., & Ford, A. C. (2015) · Alimentary Pharmacology & Therapeutics · doi:10.1111/apt.13283 · Cited by 86
Tehan, P. E., Santos, D., & Chuter, V. (2016) · Vascular Medicine · doi:10.1177/1358863x16645854 · Cited by 87
Diagnostic Value of Serum IgG4 for IgG4-Related Disease
Hao, M., Liu, M., Fan, G., Yang, X., & Li, J. (2016) · Medicine · doi:10.1097/md.0000000000003785 · Cited by 92
Torres-Costoso, A. I., Martínez‐Vizcaíno, V., Álvarez‐Bueno, C., Ferri‐Morales, A., & Cavero‐Redondo, I. (2017) · Archives of Physical Medicine and Rehabilitation · doi:10.1016/j.apmr.2017.08.489 · Cited by 98
Rispo, A., Imperatore, N., Testa, A., Nardone, O. M., Luglio, G., Caporaso, N., & Castiglione, F. (2018) · Inflammatory Bowel Diseases · doi:10.1093/ibd/izy012 · Cited by 92
Yu, W.-L., & Hua, Z.-C. (2019) · Cancers · doi:10.3390/cancers11010047 · Cited by 89
Performance of 18F-FDG, 11C-Methionine, and 18F-FET PET for Glioma Grading
Katsanos, A. H., Alexiou, G. Α., FOTOPOULOS, A. D., Jabbour, P. M., Kyritsis, A. P., & Sioka, C. (2019) · Clinical Nuclear Medicine · doi:10.1097/rlu.0000000000002654 · Cited by 92
Lin, C., Chen, I.-J., Chang, K. C., Wu, W., & Özçakar, L. (2019) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2019.07.409 · Cited by 92
The prognostic role of serum uric acid levels in preeclampsia: A meta‐analysis
Bellos, I., Pergialiotis, V., Loutradis, D., & Daskalakis, G. (2020) · Journal of Clinical Hypertension · doi:10.1111/jch.13865 · Cited by 106
Park, K. J., Choi, S. H., Kim, M., Kim, J. K., & Jeong, I. G. (2021) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.27546 · Cited by 103
Feltner, C., Wallace, I., Kistler, C. E., Coker-Schwimmer, M. J. L., & Jonas, D. E. (2021) · JAMA · doi:10.1001/jama.2020.24855 · Cited by 94
Russo, G. I., Sholklapper, T. N., Cocci, A., Broggi, G., Caltabiano, R., Smith, A. B., Lotan, Y., Morgia, G., Kamat, A. M., Witjes, J. A., et al. (2021) · Cancers · doi:10.3390/cancers13174378 · Cited by 100
Stals, M. A. M., Takada, T., Kraaijpoel, N., van Es, N., Buller, H. R., Courtney, D. M., Freund, Y., Galipienzo, J., Gal, G. L., Ghanima, W., et al. (2021) · Annals of Internal Medicine · doi:10.7326/m21-2625 · Cited by 97
Xpert MTB/RIF Ultra assay for tuberculosis disease and rifampicin resistance in children
Kay, A. W., Ness, T. E., Verkuijl, S. E., Viney, K. A., Brands, A., Masini, T., Fernández, L. G., Eisenhut, M., Detjen, A., Mandalakas, A. M., et al. (2022) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd013359.pub3 · Cited by 124
Blanco‐Pintos, T., Regueira‐Iglesias, A., Seijo‐Porto, I., Balsa‐Castro, C., Castelo‐Baz, P., Nibali, L., & Tomás, I. (2023) · Journal Of Clinical Periodontology · doi:10.1111/jcpe.13854 · Cited by 99
Records Needed for Orthodontic Diagnosis and Treatment Planning: A Systematic Review
Rischen, R. J., Breuning, K. H., Bronkhorst, E. M., & Kuijpers‐Jagtman, A. M. (2013) · PLoS ONE · doi:10.1371/journal.pone.0074186 · Cited by 94
Russo, F. M., Eastwood, M. P., Keijzer, R., Almaary, J., Toelen, J., Mieghem, T. V., & Deprest, J. A. (2016) · Ultrasound in Obstetrics and Gynecology · doi:10.1002/uog.16000 · Cited by 92
Umbilical lactate as a measure of acidosis and predictor of neonatal risk: a systematic review
Allanson, E., Waqar, T., White, C., Tunçalp, Ö., & Dickinson, J. E. (2016) · BJOG An International Journal of Obstetrics & Gynaecology · doi:10.1111/1471-0528.14306 · Cited by 101
Gandhi, N., Krishna, S., Booth, C. M., Breau, R. H., Flood, T. A., Morgan, S. C., Schieda, N., Salameh, J., McGrath, T. A., & McInnes, M. D. F. (2018) · British Journal of Urology · doi:10.1111/bju.14366 · Cited by 96
Eyck, B. M., Onstenk, B. D., Noordman, B. J., Nieboer, D., Spaander, M. C. W., Valkema, R., Lagarde, S. M., Wijnhoven, B. P. L., & van Lanschot, J. J. B. (2019) · Annals of Surgery · doi:10.1097/sla.0000000000003397 · Cited by 94
Straatman, J., Harmsen, A. M. K., Cuesta, M. A., Berkhof, J. H., Jansma, E. P., & van der Peet, D. L. (2015) · PLoS ONE · doi:10.1371/journal.pone.0132995 · Cited by 106
Carpenter, C. R., Pines, J. M., Schuur, J. D., Muir, M., Calfee, R. P., & Raja, A. S. (2014) · Academic Emergency Medicine · doi:10.1111/acem.12317 · Cited by 98
Khuroo, M. S., Khuroo, M. S., & Khuroo, M. S. (2015) · PLoS ONE · doi:10.1371/journal.pone.0121450 · Cited by 103
Olariu, E., Forero, C. G., Castro-Rodriguez, J. I., Rodrigo-Calvo, M. T., Álvarez, P., Martín-López, L. M., Sánchez-Toto, A., Adroher, N. D., Blasco-Cubedo, M. J., Vilagut, G., et al. (2015) · Depression and Anxiety · doi:10.1002/da.22360 · Cited by 75
Comparison of classification methods in breath analysis by electronic nose
Leopold, J. H., Bos, L. D. J., Sterk, P. J., Schultz, M. J., Fens, N., Horváth, I., Bikov, A., Montuschi, P., Natale, C. D., Yates, D. H., et al. (2015) · Journal of Breath Research · doi:10.1088/1752-7155/9/4/046002 · Cited by 99
Hydroxychloroquine and Chloroquine Retinopathy
Tsang, A. C., Ahmadi, S., Virgili, G., Gottlieb, C., Hamilton, J. B., & Coupland, S. G. (2015) · Ophthalmology · doi:10.1016/j.ophtha.2015.02.011 · Cited by 91
Razak, A., & Faden, M. (2019) · Archives of Disease in Childhood Fetal & Neonatal · doi:10.1136/archdischild-2019-316832 · Cited by 98
águeda, A. F., Monti, S. M., Luqmani, R. A., Buttgereit, F., Cid, M. C., Dasgupta, B., Dejaco, C., Mahr, A., Ponte, C., Salvarani, C., et al. (2019) · RMD Open · doi:10.1136/rmdopen-2019-001020 · Cited by 96
Qin, Y., Huang, X., Chen, H., Liu, X., Li, Y., Hou, J., Li, A., Yan, X., & Chen, Y. (2020) · BMC Infectious Diseases · doi:10.1186/s12879-020-05260-8 · Cited by 96
Kim, P. H., Suh, C. H., Baek, J. H., Chung, S. R., Choi, Y. J., & Lee, J. H. (2020) · European Radiology · doi:10.1007/s00330-020-07384-6 · Cited by 97
“The results of the quality assessment based on QUADAS-2 criteria are shown in Supplementary Figure S1.”
Feltner, C., Wallace, I. F., Aymes, S., Cook Middleton, J., Hicks, K. L., Schwimmer, M., Baker, C., Balio, C. P., Moore, D., Voisin, C. E., et al. (2022) · JAMA · doi:10.1001/jama.2022.18357 · Cited by 80
Ultrasound findings of lung ultrasonography in COVID-19: A systematic review
Gil-Rodríguez, J., de Rojas, J. P., Aranda-Laserna, P., Fernández, A. B., Martos-Ruíz, M., Peregrina-Rivas, J.-A., & Guirao‐Arrabal, E. (2022) · European Journal of Radiology · doi:10.1016/j.ejrad.2022.110156 · Cited by 91
“Quality of included studies as established in the QUADAS-2 tool [10].”
Khanagar, S. B., Alkadi, L., Alghilan, M. A., Kalagi, S., Awawdeh, M. A., Bijai, L. K., Vishwanathaiah, S., Aldhebaib, A., & Singh, O. G. (2023) · Biomedicines · doi:10.3390/biomedicines11061612 · Cited by 108
Church, E. C., Steingart, K. R., Cangelosi, G. A., Rühwald, M., Kohli, M., & Shapiro, A. E. (2023) · The Lancet Global Health · doi:10.1016/s2214-109x(23)00469-2 · Cited by 91
Faes, L., Bodmer, N. S., Bachmann, L. M., Thiel, M. A., & Schmid, M. (2014) · Eye · doi:10.1038/eye.2014.104 · Cited by 103
Sun, X., Zhou, Z., Tian, J., Wang, Z., Huang, Q., Fan, K., Mao, Y., Sun, G., & Yang, Y. (2015) · Gastrointestinal Endoscopy · doi:10.1016/j.gie.2014.12.021 · Cited by 93
Serafin, Z., Białecki, M., Białecka, A., Sconfienza, L. M., & Kłopocka, M. (2016) · Journal of Crohn's and Colitis · doi:10.1093/ecco-jcc/jjv196 · Cited by 93
Urinary biomarkers for the non-invasive diagnosis of endometriosis
Liu, E., Nisenblat, V., Farquhar, C., Fraser, I., Bossuyt, P. M., Johnson, N., & Hull, M. L. (2015) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd012019 · Cited by 89
Self-citationPillai, R. N., Konje, J. C., Tincello, D. G., & Potdar, N. (2015) · Human Reproduction Update · doi:10.1093/humupd/dmv054 · Cited by 111
Yi, J., Sun, Y., Li, Y., Li, C., Li, X., & Zhao, Z. (2016) · The Angle Orthodontist · doi:10.2319/061916-481.1 · Cited by 116
Tsoi, K. K. F., Chan, J. Y. C., Hirai, H. W., Wong, A., Mok, V., LAM, L. C. W., Kwok, T. C. Y., & Wong, S. Y. S. (2017) · Journal of the American Medical Directors Association · doi:10.1016/j.jamda.2017.05.016 · Cited by 96
Automated detection of nonmelanoma skin cancer using digital images: a systematic review
Marka, A., Carter, J. B., Toto, E., & Hassanpour, S. (2019) · BMC Medical Imaging · doi:10.1186/s12880-019-0307-7 · Cited by 89
Schueler, S., Schuetz, G. M., & Dewey, M. (2012) · Annals of Internal Medicine · doi:10.7326/0003-4819-156-4-201202210-00018 · Cited by 91
Generative artificial intelligence use in evidence synthesis: A systematic review
Clark, J., Barton, B., Albarqouni, L., Byambasuren, O., Jowsey, T., Keogh, J., Liang, T., Moro, C., O’Neill, H., & Jones, M. (2025) · Research Synthesis Methods · doi:10.1017/rsm.2025.16 · Cited by 90
Imaging in Suspected Renal-Cell Carcinoma: Systematic Review
Vogel, C., Ziegelmüller, B., Ljungberg, B., Bensalah, K., Bex, A., Canfield, S. E., Giles, R. H., Hora, M., Kuczyk, M. A., Merseburger, A. S., et al. (2018) · Clinical Genitourinary Cancer · doi:10.1016/j.clgc.2018.07.024 · Cited by 90
Monti, S. M., águeda, A. F., Luqmani, R. A., Buttgereit, F., Cid, M. C., Dejaco, C., Mahr, A., Ponte, C., Salvarani, C., Schmidt, W., et al. (2019) · RMD Open · doi:10.1136/rmdopen-2019-001003 · Cited by 97
Wu, C.-R., Tu, Y., Chuang, L., Gordon, C. J., Chen, N., Chen, P., Hasan, F., Kurniasari, M. D., Susanty, S., & Chiu, H. (2020) · Sleep Medicine Reviews · doi:10.1016/j.smrv.2020.101355 · Cited by 94
Autism spectrum disorder and pupillometry: A systematic review and meta-analysis
de Vries, L. M., Fouquaet, I., Boets, B., Naulaers, G., & Steyaert, J. G. (2020) · Neuroscience & Biobehavioral Reviews · doi:10.1016/j.neubiorev.2020.09.032 · Cited by 101
Diagnostic accuracy of examination tests for lateral elbow tendinopathy (LET) – A systematic review
Karanasios, S., Korakakis, V., Moutzouri, M., Drakonaki, E. E., Koci, K., Pantazopoulou, V., Tsepis, E., & Gioftsos, G. (2021) · Journal of Hand Therapy · doi:10.1016/j.jht.2021.02.002 · Cited by 104
Bernhardt, L., Brady, E. M., Freeman, S. C., Polmann, H., Réus, J. C., Flores‐Mir, C., Canto, G. D. L., Robertson, N., & Squire, I. B. (2021) · Sleep And Breathing · doi:10.1007/s11325-021-02450-9 · Cited by 93
Alabousi, M., Alabousi, A., Adham, S., Pozdnyakov, A., Ramadan, S., Chaudhari, H., Young, J. E. M., Gupta, M. K., & Harish, S. (2021) · JAMA Otolaryngology–Head & Neck Surgery · doi:10.1001/jamaoto.2021.3387 · Cited by 103
Leonardi, M., Uzuner, C., Mestdagh, W., Lü, C., Guerriero, S., Zajicek, M., Dückelmann, A. M., Filippi, F., Buonomo, F., Pascual, M. A., et al. (2022) · Ultrasound in Obstetrics and Gynecology · doi:10.1002/uog.24936 · Cited by 102
Jha, N., Lee, K.-S., & Kim, Y.-J. (2022) · PLOS ONE · doi:10.1371/journal.pone.0272715 · Cited by 64
Broger, T., Koeppel, L., Huerga, H., Miller, P., Gupta‐Wright, A., Blanc, F. –., Esmail, A., Reeve, B. W. P., Floridia, M., Kerkhoff, A. D., et al. (2023) · The Lancet Global Health · doi:10.1016/s2214-109x(23)00135-3 · Cited by 96
Zhao, Y., & Bergmann, J. (2023) · Sensors · doi:10.3390/s23177439 · Cited by 103
Rodrigo, E., López‐Hoyos, M., Corral, M., Fábrega, E., Fernández‐Fresnedo, G., Segundo, D. S., Piñera, C., & Arias, M. (2012) · Liver Transplantation · doi:10.1002/lt.23497 · Cited by 90
Navaneethan, U., Njei, B. M., Venkatesh, P. G. K., Lourdusamy, V., & Sanaka, M. R. (2014) · Gastroenterology report · doi:10.1093/gastro/gou057 · Cited by 96
Husby, J. A., Reitan, B. C., Biermann, M., Trovik, J., Bjørge, L., Magnussen, I. J., Salvesen, Ø. O., Salvesen, H. B., & Haldorsen, I. S. (2015) · Journal of Nuclear Medicine · doi:10.2967/jnumed.115.159913 · Cited by 90
Xiao, H., Shi, M., Xie, Y., & Chi, X. (2017) · PLoS ONE · doi:10.1371/journal.pone.0186660 · Cited by 90
Cassiani-Miranda, C. A., Cuadros-Cruz, A. K., Torres-Pinzón, H., Scoppetta, O., Pinzón-Tarrazona, J. H., López-Fuentes, W. Y., Paez, A., Cabanzo-Arenas, D. F., Ribero-Marulanda, S., & Llanes-Amaya, E. R. (2021) · Revista Colombiana de Psiquiatría · doi:10.1016/j.rcp.2019.09.001 · Cited by 89
Leung, A. A., Symonds, C. J., Hundemer, G. L., Ronksley, P. E., Lorenzetti, D. L., Pasieka, J. L., Harvey, A., & Kline, G. A. (2022) · Hypertension · doi:10.1161/hypertensionaha.122.19377 · Cited by 89
Dopamine transporter imaging for the diagnosis of dementia with Lewy bodies
McCleery, J., Morgan, S., Bradley, K. M., Noel-Storr, A. H., Ansorge, O., & Hyde, C. (2015) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd010633.pub2 · Cited by 89
Calcitonin testing for detection of medullary thyroid cancer in people with thyroid nodules
Verbeek, H. H. G., de Groot, J. W. B., Sluiter, W. J., Kobold, A. C. M., van den Heuvel, E. R., Plukker, J. T., & Links, T. P. (2020) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd010159.pub2 · Cited by 103
McInnes, M. D. F., Hibbert, R. M., Inácio, J. R., & Schieda, N. (2015) · Radiology · doi:10.1148/radiol.2015154033 · Cited by 99
Systematic review of 3D mammography for breast cancer screening
Hodgson, R. M., Heywang-Köbrunner, S. H., Harvey, S. C., Edwards, M., Shaikh, J., Arber, M. R., & Glanville, J. (2016) · The Breast · doi:10.1016/j.breast.2016.01.002 · Cited by 89
Cozzolino, M., Vitagliano, A., di Giovanni, M. V., Laganà, A. S., Vitale, S. G., Blaganje, M., Starič, K. D., Kobal, B., Patrelli, T. S., & Noventa, M. (2018) · Reproductive BioMedicine Online · doi:10.1016/j.rbmo.2018.01.015 · Cited by 89
Zhang, X., Ye, H., & Li, Y. (2018) · Applied Nursing Research · doi:10.1016/j.apnr.2018.04.006 · Cited by 96
Pulmonary function tests as outcomes for systemic sclerosis interstitial lung disease
Caron, M., Hoa, S. A.-T., Hudson, M., Schwartzman, K., & Steele, R. J. (2018) · European Respiratory Review · doi:10.1183/16000617.0102-2017 · Cited by 98
Guirguis‐Blake, J., Evans, C. V., Redmond, N., & Lin, J. S. (2018) · JAMA · doi:10.1001/jama.2018.4250 · Cited by 107
Hamada, Y., Lujan, J., Schenkel, K., Ford, N. P., & Getahun, H. (2018) · The Lancet HIV · doi:10.1016/s2352-3018(18)30137-1 · Cited by 107
A cross-cultural study of autistic traits across India, Japan and the UK
Carruthers, S., Kinnaird, E., Rudra, A., Smith, P., Allison, C., Auyeung, B., Chakrabarti, B., Wakabayashi, A., Baron-Cohen, S., Bakolis, I., et al. (2018) · Molecular Autism · doi:10.1186/s13229-018-0235-3 · Cited by 79
Satapathy, S., Singh, H., Kumar, R., & Mittal, B. R. (2020) · American Journal of Roentgenology · doi:10.2214/ajr.20.23912 · Cited by 95
van den Berg, F. F., de Bruijn, A. C., van Santvoort, H. C., Issa, Y., & Boermeester, M. A. (2020) · Pancreatology · doi:10.1016/j.pan.2020.09.007 · Cited by 99
Guchelaar, N. A. D., Waling, M. M., Adhin, A. A., van Daele, P. L. A., Schreurs, M. W. J., & Rombach, S. M. (2020) · Autoimmunity Reviews · doi:10.1016/j.autrev.2020.102716 · Cited by 96
Khaw, J., Subramaniam, P., Aziz, N. A. A., Raymond, A. A., Zaidi, W. A. W., & Ghazali, S. E. (2021) · International Journal of Environmental Research and Public Health · doi:10.3390/ijerph18178962 · Cited by 94
Diagnostic Accuracy of Ultrasonography for Rotator Cuff Tears: A Systematic Review and Meta-analysis
Farooqi, A. S., Lee, A., Novikov, D., Kelly, A. M., Li, X., Kelly, J. D. A., & Parisien, R. L. (2021) · Orthopaedic Journal of Sports Medicine · doi:10.1177/23259671211035106 · Cited by 89
Detection of cerebral aneurysms using artificial intelligence: a systematic review and meta-analysis
Din, M., Agarwal, S., Grzeda, M. T., Wood, D. A., Modat, M., & Booth, T. C. (2022) · Journal of NeuroInterventional Surgery · doi:10.1136/jnis-2022-019456 · Cited by 96
“…& Imaging Sciences in particular, Giusi Manfredi, Vicky Goh, Patrick Wong, Denise Barton, Valentina Vitiello and Sebastien Ourselin, as well as (2) from King’s College Hospital NHS Foundation Trust, in particular, Ann-Marie Murtagh, Jasmine Palmer and all others in R & I, and Jonnie…”
Ravaioli, F., Dajti, E., Mantovani, A., Newsome, P. N., Targher, G., & Colecchia, A. (2023) · Gut · doi:10.1136/gutjnl-2022-328689 · Cited by 97
Serafin, M., Baldini, B., Cabitza, F., Carrafiello, G., Baselli, G., FABBRO, M. D., Sforza, C., Caprioglio, A., & Tartaglia, G. M. (2023) · La radiologia medica · doi:10.1007/s11547-023-01629-2 · Cited by 89
Pedrett, R., Mascagni, P., Beldi, G., Padoy, N., & Lavanchy, J. L. (2023) · Surgical Endoscopy · doi:10.1007/s00464-023-10335-z · Cited by 102
Hayden, M. K., Mikati, I. K. E., Hanson, K. E., Englund, J. A., Humphries, R. M., Lee, F., Loeb, M. B., Morgan, D. J., Patel, R., Ta’ani, O. A., et al. (2024) · Clinical Infectious Diseases · doi:10.1093/cid/ciae121 · Cited by 93
Hendrickx, J., Gracea, R. S., Vanheers, M., Winderickx, N., Preda, F., Shujaat, S., & Jacobs, R. (2024) · European Journal of Orthodontics · doi:10.1093/ejo/cjae029 · Cited by 101
Detection of Sleep Apnea Using Wearable AI: Systematic Review and Meta-Analysis
Abd-Alrazaq, A. A., Aslam, H., AlSaad, R., Alsahli, M. A., Ahmed, A., Damseh, R., Aziz, S., & Sheikh, J. I. (2024) · Journal of Medical Internet Research · doi:10.2196/58187 · Cited by 124
“To evaluate the quality of the studies included in our review, we adapted the Quality Assessment of Studies of Diagnostic Accuracy-Revised (QUADAS-2) [32] tool to align with our review’s specific objectives.”
Boland, J. W., McWilliams, K., Ahmedzai, S. H., & Pockley, A. G. (2014) · British Journal of Cancer · doi:10.1038/bjc.2014.384 · Cited by 95
Prediction of oral appliance treatment outcomes in obstructive sleep apnea: A systematic review
Okuno, K., Pliska, B. T., Hamoda, M. M., Lowe, A. A., & Almeida, F. R. (2015) · Sleep Medicine Reviews · doi:10.1016/j.smrv.2015.11.007 · Cited by 100
Prognostic value of procalcitonin in pneumonia: A systematic review and meta‐analysis
Liu, D., Su, L., Guan, W. P., Xiao, K., & Xie, L. (2015) · Respirology · doi:10.1111/resp.12704 · Cited by 89
Liou, K., Negishi, K., Ho, S., Russell, E. A., Cranney, G., & Ooi, S. (2016) · Journal of the American Society of Echocardiography · doi:10.1016/j.echo.2016.03.002 · Cited by 91
Jalalzadeh, H., Indrakusuma, R., Planken, R. N., Legemate, D. A., Koelemay, M. J. W., & Balm, R. (2016) · European Journal of Vascular and Endovascular Surgery · doi:10.1016/j.ejvs.2016.05.002 · Cited by 91
de Heer, K., Gerritsen, M. G., Visser, C. E., & Leeflang, M. (2019) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd012399.pub2 · Cited by 104
Self-citationNevis, I. F., Binkley, K., & Kabali, C. (2016) · Allergy, Asthma & Clinical Immunology · doi:10.1186/s13223-016-0126-0 · Cited by 88
Lee, S., Chu, Y., Ryu, J., Park, Y. J., Yang, S., & Koh, S. B. (2022) · Yonsei Medical Journal · doi:10.3349/ymj.2022.63.s93 · Cited by 88
“10 However, since the validity of using the scale has not been verified for AI studies, it was not used to determine whether to include or exclude a particular study.”
Accuracy of the GLIM criteria for diagnosing malnutrition: A systematic review and meta-analysis
Huo, Z., Chong, F., Yin, L., Lu, Z., Liu, J., & Xu, H. (2022) · Clinical Nutrition · doi:10.1016/j.clnu.2022.04.005 · Cited by 88
Imaging for the exclusion of pulmonary embolism in pregnancy
van Mens, T. E., Scheres, L. J., de Jong, P. G., Leeflang, M. M., Nijkeuter, M., & Middeldorp, S. (2017) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd011053.pub2 · Cited by 81
Self-citationMersy, E., Smits, L. J. M., van Winden, L. A. A. P., de Die-Smulders, C. E. M., Paulussen, A. D. C., Macville, M. V. E., Coumans, A. B. C., & Frints, S. G. M. (2013) · Human Reproduction Update · doi:10.1093/humupd/dmt001 · Cited by 98
Isautier, J., Bosnić, M., Yeung, S. S. Y., Trappenburg, M. C., Meskers, C. G. M., Phillips, A. C., & Maier, A. B. (2019) · Journal of the American Medical Directors Association · doi:10.1016/j.jamda.2019.06.024 · Cited by 99
Metadata
- Authors
- Whiting, P. F., Rutjes, A. W. S., Westwood, M. E., Mallett, S., Deeks, J. J., Reitsma, J. B., Leeflang, M. M. G., Sterne, J. A. C., Bossuyt, P. M. M., & the QUADAS-2 Group*
- Affiliations
- University of Bern (CH)
- Corresponding author
- Whiting, Penny F.
- ORCID
- Venue
- Annals of Internal Medicine
- Publisher
- American College of Physicians
- Published
- 2011-10-18
- Volume
- 155
- Issue
- 8
- Pages
- 529-536
- ISSN
- 0003-4819 (ISSN-L)
- 1539-3704
- OpenAlex
- W2107638293
- Semantic Scholar
- 8a5d0b5a9271ea14bcb8479bc32d3844a80655b9
- Cited by
- 14,199
- References
- 18
- Citations by year
- 2026: 1484 · 2025: 1569 · 2024: 1524 · 2023: 1305 · 2022: 1420 · 2021: 1514 · 2020: 1245 · 2019: 955 · 2018: 767 · 2017: 637 · 2016: 580 · 2015: 528 · 2014: 363 · 2013: 217 · 2012: 75
- FWCI
- 224.36
- Type
- journal article
- Language
- en
- Open access
- green
- hdl.handle.net
- Licence
- cc-by
- www.acpjournals.org/journal/aim/text-and-data-mining (tdm)
- Locations
- Annals of Internal Medicine (publishedVersion)
- PubMed (publishedVersion)
- Pure Amsterdam UMC (publishedVersion)
- Data Archiving and Networked Services (DANS) (submittedVersion)
- Florence Research (University of Florence) (submittedVersion)
- IRIS UNIMORE (University of Modena and Reggio Emilia) (submittedVersion, cc-by)
- University of Birmingham Research Portal (University of Birmingham) (submittedVersion)
- Bristol Research (University of Bristol) (submittedVersion)
- Funders
- Cancer Research UK
- Topics
- Social Sciences › Decision Sciences › Statistics, Probability and Uncertainty › Meta-analysis and systematic reviews
- Physical Sciences › Mathematics › Statistics and Probability › Statistical Methods in Epidemiology
- Health Sciences › Medicine › Public Health, Environmental and Occupational Health › Clinical practice guidelines implementation
- Keywords
- QUADAS-2, diagnostic accuracy studies, quality assessment, risk of bias, applicability, patient selection, index tests, reference materials, flowcharts, systematic reviews
- MeSH terms
- Diagnosis, Humans, Quality Control, Surveys and Questionnaires, Reference Standards, Review Literature as Topic, Time Factors, Bias, Patient Selection, Evidence-Based Medicine
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
A language model drew the claims from the paper on 2026-11-23, under version 3 of the claim definition (model deepseek-v4.1-flash, prompt extract-v3).
A second model labelled each claim on 2026-11-23 (model jev-1.13-20260917, definition revision gold-guideline-v0.2).
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.