QUADAS-2: A Revised Tool for the Quality Assessment of Diagnostic Accuracy Studies
Open accessThe DOI matches its Crossref record; 18 of the 18 references it cites were found in a registry or an index; none of the 21 sources its claims cite is checked for support yet.
Abstract
In 2003, the QUADAS tool for systematic reviews of diagnostic accuracy studies was developed. Experience, anecdotal reports, and feedback suggested areas for improvement; therefore, QUADAS-2 was developed. This tool comprises 4 domains: patient selection, index test, reference standard, and flow and timing. Each domain is assessed in terms of risk of bias, and the first 3 domains are also assessed in terms of concerns regarding applicability. Signalling questions are included to help judge risk of bias. The QUADAS-2 tool is applied in 4 phases: summarize the review question, tailor the tool and produce review-specific guidance, construct a flow diagram for the primary study, and judge bias and applicability. This tool will allow for more transparent rating of bias and applicability of primary diagnostic accuracy studies.
Overview
CoChat Summary
TL;DR
QUADAS-2 is a revised tool for assessing risk of bias and applicability in diagnostic accuracy studies, developed through a 4-stage evidence-based consensus process. It replaces the original QUADAS “yes/no/unclear” quality rating with domain-level judgments of low, high, or unclear risk of bias and concerns about applicability.
Key findings
- QUADAS-2 separates “quality” into risk of bias and concerns regarding applicability, defining quality as the degree to which diagnostic accuracy estimates avoided bias and the extent to which primary studies are applicable to the review question.
- The tool has 4 key domains—patient selection, index test, reference standard, and flow and timing—with the first 3 also assessed for applicability; it is completed in 4 phases and uses signaling questions to help judge risk of bias.
- Development drew on 4 reviews: 54 diagnostic accuracy reviews published between 2007 and 2009, structured feedback from 64 systematic reviewers who had used QUADAS, 101 studies on sources of bias and variation, and 8 studies evaluating QUADAS; a 1-day consensus meeting had 24 attendees, and piloting occurred in 5 reviews.
- Interrater reliability varied considerably, with better agreement on applicability than on risk of bias; all participants preferred QUADAS-2 to the original tool, but the authors could not currently include criteria for studies comparing multiple index tests because the evidence base was insufficient.
Methods
- Tool development followed Moher and colleagues’ 4-stage approach: define the scope, review the evidence base, hold a face-to-face consensus meeting, and refine through piloting.
- A steering group of 9 experts set the scope; the consensus meeting was held on 21 September 2010 in Birmingham, United Kingdom, with 24 attendees who split into groups of 4 to 6 participants; multiple rounds of piloting used online questionnaires and other feedback, including pairs of reviewers piloting QUADAS-2 in 5 reviews.
- No primary statistical analysis was reported; the work synthesized evidence reviews, consensus decisions, and pilot feedback to produce and refine the tool.
Limitations
- Stated: the authors decided they cannot currently include criteria for assessing studies that compare multiple index tests within QUADAS-2 because of the limited evidence base on risk of bias and sources of variation in such studies, and they plan future work on this topic.
- Stated: piloting showed poor interrater reliability and problems applying the domain on comparative accuracy studies; interrater reliability varied considerably overall, with better agreement on applicability than on risk of bias.
- Evident from the text: full details of the 4 evidence reviews were to be published separately, and the main text reports no quantitative reliability estimates, referring instead to an Appendix Table.
Model-written summary. Check it against the paper before relying on it.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
0 Valid · 0 Not valid · 16 Not checked · 24 Own results and interpretations
In the paper
“In a review on anti-cyclic citrullinated peptide antibodies for diagnosing rheumatoid arthritis (10), we found that some studies enrolled consecutive participants with confirmed diagnoses. In these studies, testing for anticyclic citrullinated peptide antibody showed greater sensitivity than in studies that included patients with suspected disease but an unconfirmed diagnosis (that is, difficult-t”
§ QUADAS-2: A Revised Tool for the Quality Assessment of Diagnostic Accuracy Studies > Signaling question 2: Was a case-control design avoided? Signaling question 3: Did the study avoid inappropriate exclusions?
What the sources say
- Not matchedcites [10]
The reference list we hold has no entry [10].
plainstates an association- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Not matched
A statement the paper makes itself — it cites no source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“Studies that make inappropriate exclusions (for example, not including”
§ QUADAS-2: A Revised Tool for the Quality Assessment of Diagnostic Accuracy Studies > Signaling question 2: Was a case-control design avoided? Signaling question 3: Did the study avoid inappropriate exclusions?
hedgedstates a possible cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
None of the sources cited for this claim could be matched to a paper, so there is nothing to check it against.
In the paper
“Because the accuracy of a test may depend on where it will be used in the diagnostic pathway, review authors are asked to describe patients in terms of setting, intended use of the index test, patient presentation, and previous testing (8,9).”
§ QUADAS-2: A Revised Tool for the Quality Assessment of Diagnostic Accuracy Studies > Phase 1: Review Question
What the sources say
- Not matchedcites [8]
The reference list we hold has no entry [8].
- Not matchedcites [9]
The reference list we hold has no entry [9].
hedgedstates a possible cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Not matched
In the paper
“Development of QUADAS-2 was based on the 4-stage approach proposed by Moher and colleagues (4): define the scope, review the evidence base, hold a face-to-face consensus meeting, and refine the tool through piloting.”
§ QUADAS-2: A Revised Tool for the Quality Assessment of Diagnostic Accuracy Studies > METHODS
What the sources say
- Not matchedcites [4]
The reference list we hold has no entry [4].
plainstates a cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: unclear — It is unclear whether the paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Not matched
None of the sources cited for this claim could be matched to a paper, so there is nothing to check it against.
In the paper
“Studies enrolling participants with known disease and a control group without the condition may similarly exaggerate diagnostic accuracy (7,11).”
§ QUADAS-2: A Revised Tool for the Quality Assessment of Diagnostic Accuracy Studies > Signaling question 2: Was a case-control design avoided? Signaling question 3: Did the study avoid inappropriate exclusions?
What the sources say
- Not matchedcites [7]
The reference list we hold has no entry [7].
- Not matchedcites [11]
The reference list we hold has no entry [11].
hedgedstates a possible cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Not matched
10 more claims
Create a free account to see all 40 claims and every source verdict.
- Probably not a substantial claim. 19
- It may state two separate claims as one. 16
- The quote only partly states this claim. 2
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“We assessed the study-level risk of bias with the QUADAS-2 tool”
In the citing paper
“We developed a revised risk-of-bias assessment tool to address these issues, incorporate advances in assessment of risk of bias used in other recently developed tools, 9 10 and integrate recent developments in estimation of intervention effects from randomised trials. 11”
From RoB 2: a revised tool for assessing risk of bias in randomised trials (2019) · cites this paper as [10]
In the citing paper
“Two reviewers independently assessed the quality of the included studies with the Quality Assessment of Diagnostic Accuracy Studies (Quadas-2) [33].”
From High-standard predictive equations for estimating body composition using bioelectrical impedance analysis: a systematic review (2024) · cites this paper as [33]
In the citing paper
“The quality of the selected studies was rigorously assessed using the Checklist for Artificial Intelligence in Medical Imaging (CLAIM) alongside the Quality Assessment of Diagnostic Accuracy Studies-2 (QUADAS-2).23,24”
From Artificial Intelligence Detection and Segmentation Models: A Systematic Review and Meta-Analysis of Brain Tumors in Magnetic Resonance Imaging (2024) · cites this paper as [24]
In the citing paper
“The methodological quality of each selected study was assessed according to the Quality Assessment of Diagnostic Accuracy Studies (QUADAS-2) checklist [15]”
From The diagnostic accuracy of digital, infrared and mercury-in-glass thermometers in measuring body temperature: a systematic review and network meta-analysis (2021) · cites this paper as [15]
20 more claims about this paper
Create a free account to see every claim other papers make about this one.
Citations
Cites
The Cochrane Collaboration's tool for assessing risk of bias in randomised trials
Higgins, J. P. T., Altman, D. G., Gotzsche, P. C., Juni, P., Moher, D., Oxman, A. D., Savovic, J., Schulz, K. F., Weeks, L., Sterne, J. A. C., et al. (2011) · BMJ · doi:10.1136/bmj.d5928 · Cited by 33,817
Self-citationWhiting, P., Rutjes, A. W., Reitsma, J. B., Bossuyt, P. M., & Kleijnen, J. (2003) · BMC Medical Research Methodology · doi:10.1186/1471-2288-3-25 · Cited by 3,592
Self-citationThe Hazards of Scoring the Quality of Clinical Trials for Meta-analysis
Jüni, P. (1999) · JAMA · doi:10.1001/jama.282.11.1054 · Cited by 1,981
Empirical evidence of design-related bias in studies of diagnostic tests.
Lijmer, J. G. (1999) · JAMA · doi:10.1001/jama.282.11.1061 · Cited by 1,861 · cited 2×
“Studies enrolling participants with known disease and a control group without the condition may similarly exaggerate diagnostic accuracy (7, 11).”
BackgroundGuidance for Developers of Health Research Reporting Guidelines
Moher, D., Schulz, K. F., Simera, I., & Altman, D. G. (2010) · PLoS Medicine · doi:10.1371/journal.pmed.1000217 · Cited by 1,437
Systematic Reviews of Diagnostic Test Accuracy
Leeflang, M. M. G., Deeks, J. J., Gatsonis, C., & Bossuyt, P. M. M. (2008) · Annals of Internal Medicine · doi:10.7326/0003-4819-149-12-200812160-00008 · Cited by 1,124
Self-citationSources of Variation and Bias in Studies of Diagnostic Accuracy: A Systematic Review
Whiting, P., Rutjes, A. W. S., Reitsma, J. B., Glas, A. S., Bossuyt, P. M. M., & Kleijnen, J. (2004) · Annals of Internal Medicine · doi:10.7326/0003-4819-140-3-200402030-00010 · Cited by 798 · cited 4×
“The third review was an update on sources of bias and variation in diagnostic accuracy studies that included 101 studies (7).”
BackgroundInfluentialSelf-citationEvaluation of QUADAS, a tool for the quality assessment of diagnostic accuracy studies
Whiting, P. F., Weswood, M. E., Rutjes, A. W., Reitsma, J. B., Bossuyt, P. N., & Kleijnen, J. (2006) · BMC Medical Research Methodology · doi:10.1186/1471-2288-6-9 · Cited by 769
Self-citationLeeflang, M. M. G., Moons, K. G. M., Reitsma, J. B., & Zwinderman, A. H. (2008) · Clinical Chemistry · doi:10.1373/clinchem.2007.096032 · Cited by 346 · cited 1×
“Test performance is likely to be poorer in an independent sample of patients in whom the same threshold is used (12).”
BackgroundSelf-citationNo role for quality scores in systematic reviews of diagnostic accuracy studies
Whiting, P., Harbord, R., & Kleijnen, J. (2005) · BMC Medical Research Methodology · doi:10.1186/1471-2288-5-19 · Cited by 337
Self-citation
Cited by
Items 1,401–1,500 of 14,770
Bowden, S. J., Kalliala, I. E. J., Veroniki, A. A., Arbyn, M., Mitra, A., Lathouras, K., Mirabello, L. J., Chadeau‐Hyam, M., Paraskevaidis, E. A., Flanagan, J. M., et al. (2019) · EBioMedicine · doi:10.1016/j.ebiom.2019.10.053 · Cited by 97
Chiu, Y., Chang, K. C., Chen, I.-J., Wu, W., & Özçakar, L. (2020) · European Radiology · doi:10.1007/s00330-020-07059-2 · Cited by 95
Roberts, N. P., Kitchiner, N., Lewis, C., Downes, A. J., & Bisson, J. I. (2021) · European Journal of Psychotraumatology · doi:10.1080/20008198.2020.1863578 · Cited by 92
Franciotti, R., Moharrami, M., Quaranta, A. A., Bizzoca, M. E., Piattelli, A., Aprile, G., & Perrotti, V. (2021) · Osteoporosis International · doi:10.1007/s00198-021-05852-3 · Cited by 87
Lunny, C., Ramasubbu, C., Puil, L. J., Liu, T. W. B., Gerrish, S., Salzwedel, D. M., Mintzes, B. J., & Wright, J. M. (2021) · PLoS ONE · doi:10.1371/journal.pone.0250356 · Cited by 96
Deng, K., Pelekos, G., Jin, L., & Tonetti, M. S. (2021) · Journal Of Clinical Periodontology · doi:10.1111/jcpe.13485 · Cited by 93
Kawada, T., Yanagisawa, T., Rajwa, P., Motlagh, R. S., Mostafaei, H., Quhal, F., Laukhtina, E., Aydh, A., König, F., Pallauf, M., et al. (2022) · European Urology Oncology · doi:10.1016/j.euo.2022.04.006 · Cited by 97
Neeter, L. M. F. H., Robbe, M. M. Q., van Nijnatten, T. J. A., Jochelson, M. S., Raat, H., Wildberger, J. E., Smidt, M. L., Nelemans, P. J., & Lobbes, M. B. I. (2023) · Journal of Cancer · doi:10.7150/jca.79747 · Cited by 89
Nguyen, H. S., Ho, D. K. N., Nguyen, N. N., Tran, H. M., Tam, K., & Le, N. Q. K. (2023) · Academic Radiology · doi:10.1016/j.acra.2023.03.040 · Cited by 97
Part 5: Acute Coronary Syndromes
Welsford, M., Nikolaou, N. I., Beygui, F., Bossaert, L. L., Ghaemmaghami, C. A., Nonogi, H., O’Connor, R. E., Pichel, D. R., Scott, T., Walters, D., et al. (2015) · Circulation · doi:10.1161/cir.0000000000000274 · Cited by 88
Tang, R., Wang, J. T.-Y., Wang, L., Le, K., Huang, Y., Hickey, A. J., & Emmett, L. (2015) · Clinical Nuclear Medicine · doi:10.1097/rlu.0000000000001063 · Cited by 88
Adams, H. J. A., & Kwee, T. C. (2016) · European Journal of Radiology · doi:10.1016/j.ejrad.2016.08.011 · Cited by 94
The Accuracy of Imaging Techniques in the Assessment of Periprosthetic Hip Infection
Verberne, S. J., Raijmakers, P. G. H. M., & Temmerman, O. P. P. (2016) · Journal of Bone and Joint Surgery · doi:10.2106/jbjs.15.00898 · Cited by 88
Diagnostic and prognostic value of circulating tumor DNA in gastric cancer: a meta-analysis
Gao, Y., Zhang, K., Xi, H., Cai, A., Wu, X., Cui, J., Li, J., Qiao, Z., Wei, B., & Chen, L. (2016) · Oncotarget · doi:10.18632/oncotarget.14064 · Cited by 90
Autism Spectrum Disorder Screening Instruments for Very Young Children: A Systematic Review
Towle, P. O., & Patrick, P. A. (2016) · Autism Research and Treatment · doi:10.1155/2016/4624829 · Cited by 103
Noninvasive diagnostic tools for pelvic congestion syndrome: a systematic review
Steenbeek, M. P., van der Vleuten, C. J. M., Kool, L. J. S., & Nieboer, T. E. (2018) · Acta Obstetricia Et Gynecologica Scandinavica · doi:10.1111/aogs.13311 · Cited by 88
Accuracy and Usefulness of CBCT in Periodontology: A Systematic Review of the Literature
Woelber, J. P., Fleiner, J., Rau, J., Ratka‐Krüger, P., & Hannig, C. (2018) · The International Journal of Periodontics & Restorative Dentistry · doi:10.11607/prd.2751 · Cited by 98
Ten simple rules for carrying out and writing meta-analyses
Forero, D. A., López‐León, S., González‐Giraldo, Y., & Bagos, P. G. (2019) · PLoS Computational Biology · doi:10.1371/journal.pcbi.1006922 · Cited by 95
Human-AI interaction in skin cancer diagnosis: a systematic review and meta-analysis
Krakowski, I., Kim, J., Cai, Z. R., Daneshjou, R., Lapins, J., Eriksson, H., Lykou, A., & Linos, E. (2024) · npj Digital Medicine · doi:10.1038/s41746-024-01031-w · Cited by 87
Prediction of resistance to chemotherapy in ovarian cancer: a systematic review
Lloyd, K. L., Cree, I. A., & Savage, R. S. (2015) · BMC Cancer · doi:10.1186/s12885-015-1101-8 · Cited by 87
Chou, R., Cottrell, E. B., Wasson, N., Rahman, B., & Guise, J. (2013) · Annals of Internal Medicine · doi:10.7326/0003-4819-158-2-201301150-00574 · Cited by 87
Liu, B., Zheng, Y., Huang, G., Lin, M., Shan, Q., Lu, Y., Tian, W., & Xie, X. (2016) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2015.10.024 · Cited by 99
Ge, L., Pan, B., Song, F., Ma, J., Zeraatkar, D., Zhou, J., & Tian, J. (2017) · BMJ Open · doi:10.1136/bmjopen-2017-018175 · Cited by 97
de Zwart, P. L., van Dijken, B. R. J., Holtman, G. A., Stormezand, G. N., Dierckx, R. A. J. O., van Laar, P. J., & van der Hoorn, A. (2019) · Journal of Nuclear Medicine · doi:10.2967/jnumed.119.233809 · Cited by 88
Imaging tests for the detection of osteomyelitis: a systematic review
Llewellyn, A., Jones-Diette, J. S., Kraft, J. K., Holton, C., Harden, M., & Simmonds, M. C. (2019) · Health Technology Assessment · doi:10.3310/hta23610 · Cited by 88
Li, W., Wang, Y., Wen, J., Zhang, L., & Sun, Y. (2020) · American Journal of Roentgenology · doi:10.2214/ajr.19.22691 · Cited by 91
First Metatarsal Rotation in Hallux Valgus Deformity
Steadman, J. N., Barg, A., & Saltzman, C. L. (2021) · Foot & Ankle International · doi:10.1177/1071100721997149 · Cited by 87
Westwood, M. E., Ramaekers, B. L. T., Grimm, S. E., Worthy, G., Fayter, D., Armstrong, N., Buksnys, T., Ross, J., Joore, M. A., & Kleijnen, J. (2021) · Health Technology Assessment · doi:10.3310/hta25330 · Cited by 99
Self-citationSchuttert, I., Timmerman, H., Petersen, K. K., McPhee, M. E., Arendt‐Nielsen, L., Reneman, M. F., & Wolff, A. P. (2021) · Journal of Clinical Medicine · doi:10.3390/jcm10245931 · Cited by 96
Suri, J. S., Bhagawati, M., Paul, S., Protogeron, A., Sfikakis, P. P., Kitas, G. D., Khanna, N. N., Ruzsa, Z., Sharma, A. M., Saxena, S., et al. (2022) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2021.105204 · Cited by 86
Pillay, S., Steingart, K. R., Davies, G., Chaplin, M., de Vos, M., Schumacher, S. G., Warren, R. M., & Theron, G. (2022) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd014841.pub2 · Cited by 102
Huang, Y., Chen, C.-J., Shao, S., Li, C.-H., Hsiao, C.-H., Niu, K.-Y., & Yen, C. (2023) · Critical Care Medicine · doi:10.1097/ccm.0000000000005820 · Cited by 96
Jung, J.-Y., Dai, J., Liu, B., & Wu, Q. F. (2024) · PLOS Digital Health · doi:10.1371/journal.pdig.0000438 · Cited by 102
Oerther, B., Nedelcu, A., Engel, H., Schmucker, C. M., Schwarzer, G., Brugger, T., Schoots, I. G., Eisenblätter, M., Sigle, A., Gratzke, C., et al. (2024) · Radiology · doi:10.1148/radiol.233337 · Cited by 116
Al-Toma, A. A., Zingone, F., Branchi, F., Schiepatti, A., Malamut, G., Canova, C., Rosato, I., Ocagli, H., Trott, N., Elli, L., et al. (2025) · United European Gastroenterology Journal · doi:10.1002/ueg2.70119 · Cited by 101
Joshi, N. K., Lira, A., Mehta, N., Paladino, L., & Sinert, R. H. (2013) · Academic Emergency Medicine · doi:10.1111/acem.12058 · Cited by 87
van Rossum, P. S. N., Goense, L., Meziani, J., Reitsma, J. B., Siersema, P. D., Vleggaar, F. P., van Vulpen, M., Meijer, G. J., Ruurda, J. P. H., & van Hillegersberg, R. (2015) · Gastrointestinal Endoscopy · doi:10.1016/j.gie.2015.11.026 · Cited by 87
Self-citationCytokines as Biomarkers of Pancreatic Ductal Adenocarcinoma: A Systematic Review
Yako, Y. Y., Kruger, D., Smith, M., & Brand, M. (2016) · PLoS ONE · doi:10.1371/journal.pone.0154016 · Cited by 93
Brennan, J. H., Mitra, B., Synnot, A., McKenzie, J. E., Willmott, C., McIntosh, A. S., Maller, J. J., & Rosenfeld, J. V. (2016) · Sports Medicine · doi:10.1007/s40279-016-0582-1 · Cited by 95
Clinical Utility of Beck Anxiety Inventory in Clinical and Nonclinical Korean Samples
오현주, Park, K., Yoon, S., Kim, Y., Lee, S., Choi, Y. Y., & Choi, K. (2018) · Frontiers in Psychiatry · doi:10.3389/fpsyt.2018.00666 · Cited by 99
da Silva, P. H. R., Spedo, C. T., Barreira, A. A., & Leoni, R. F. (2018) · Multiple Sclerosis and Related Disorders · doi:10.1016/j.msard.2018.01.014 · Cited by 90
Ali, M. S., Sethi, J. S., Taneja, A., Musani, A. I., & Maldonado, F. (2018) · Annals of the American Thoracic Society · doi:10.1513/annalsats.201711-856oc · Cited by 86
Zhang, M., Xue, M., & He, J.-Q. (2020) · International Journal of Infectious Diseases · doi:10.1016/j.ijid.2019.09.016 · Cited by 80
Stucki, S., & Gkantidis, N. (2019) · European Journal of Orthodontics · doi:10.1093/ejo/cjz075 · Cited by 93
Park, K., Eunju, J., Yoon, S., Lee, S., & Choi, K. (2020) · Frontiers in Psychology · doi:10.3389/fpsyg.2019.02934 · Cited by 96
Birgin, E., Yang, C., Hetjens, S., Reißfelder, C., Hohenberger, P., & Rahbari, N. N. (2020) · Cancer · doi:10.1002/cncr.32735 · Cited by 86
Shan, Z., Barnden, L. R., Kwiatek, R. A., Bhuta, S., Hermens, D. F., & Lagopoulos, J. (2020) · Journal of Translational Medicine · doi:10.1186/s12967-020-02506-6 · Cited by 88
Patel, P., Patel, P. M., Bhatt, M., Braun, C., Begum, H., Wiercioch, W., Varghese, J., Wooldridge, D., Alturkmani, H. J., Thomas, M. B., et al. (2020) · Blood Advances · doi:10.1182/bloodadvances.2019001052 · Cited by 86
Soffer, S., Morgenthau, A. S., Shimon, O., Barash, Y., Konen, E., Glicksberg, B. S., & Klang, E. (2021) · Academic Radiology · doi:10.1016/j.acra.2021.05.014 · Cited by 92
Noninvasive mobile EEG as a tool for seizure monitoring and management: A systematic review
Biondi, A., Santoro, V., Viana, P. F., Laiou, P., Pal, D. K., Bruno, E., & Richardson, M. P. (2022) · Epilepsia · doi:10.1111/epi.17220 · Cited by 103
Park, S. Y., Chang, E. J., Ledeboer, N. A., Messacar, K., Lindner, M. S., Venkatasubrahmanyam, S., Bercovici, S., Wilber, J. C., Lay, M. J., Perkins, B. A., et al. (2023) · Journal of Clinical Microbiology · doi:10.1128/jcm.01855-22 · Cited by 96
Malin, G., Bugg, G., Takwoingi, Y., Thornton, J., & Jones, N. (2016) · BJOG: An International Journal of Obstetrics & Gynaecology · doi:10.1111/1471-0528.13517 · Cited by 87
Cacho-Martínez, P., García-Muñoz, Á., & Ruiz‐Cantero, M. T. (2013) · Journal of Optometry · doi:10.1016/j.optom.2013.01.004 · Cited by 86
Cognitive assessment tools in Asia: a systematic review
Rosli, R., Tan, M. P., Gray, W. K., Subramanian, P., & Chin, A. (2015) · International Psychogeriatrics · doi:10.1017/s1041610215001635 · Cited by 94
Narrow band imaging for the diagnosis of head and neck squamous cell carcinoma: A systematic review
Cosway, B., Drinnan, M. J., & Paleri, V. (2016) · Head & Neck · doi:10.1002/hed.24300 · Cited by 86
Kim, S., & Lee, S. (2017) · British Journal of Radiology · doi:10.1259/bjr.20170519 · Cited by 97
Meta‐analysis of subjective complaints of vertigo and vestibular tests after cochlear implantation
Hänsel, T., Gauger, U., Bernhard, N., Behzadi, N., Ventura, M. E. R., Hofmann, V. M., Olze, H., Knopke, S., Todt, I., & Coordes, A. (2018) · The Laryngoscope · doi:10.1002/lary.27071 · Cited by 86
Yuan, W.-H., Hsu, H.-C., Chen, Y., & Wu, C. (2020) · British Journal of Cancer · doi:10.1038/s41416-020-0928-1 · Cited by 97
Measurement tools for the diagnosis of nasal septal deviation: A systematic review
Aziz, T., Biron, V. L., Ansari, K., & Flores-Mir, C. (2014) · Journal of Otolaryngology - Head & Neck Surgery · doi:10.1186/1916-0216-43-11 · Cited by 85
Woodfield, R., UK Biobank Stroke Outcomes Group, UK Biobank Follow-up and Outcomes Working Group, & Sudlow, C. L. M. (2015) · PLoS ONE · doi:10.1371/journal.pone.0137538 · Cited by 93
Fu, J., Chen, H., Yang, J., Yi, C., & Zheng, S. S. (2014) · PLoS ONE · doi:10.1371/journal.pone.0105316 · Cited by 85
Westwood, M. E., van Asselt, A. D. I., Ramaekers, B. L. T., Whiting, P. F., Joore, M. A., Armstrong, N., Noake, C., Ross, J., Severens, J. L., & Kleijnen, J. (2014) · Health Technology Assessment · doi:10.3310/hta18620 · Cited by 89
Self-citationGuo, J. Y., Seo, Y., Ren, S., Hong, S. W., Lee, D. K., Kim, S., & Jiang, Y. (2016) · Abdominal Radiology · doi:10.1007/s00261-016-0807-7 · Cited by 90
Conway, A., Tipton, E., Liu, W.-H., Conway, Z. J., Soalheira, K., Sutherland, J., & Fingleton, J. (2018) · Thorax · doi:10.1136/thoraxjnl-2017-211466 · Cited by 90
Raffone, A., Travaglino, A., Saccone, G., Mollo, A., Placido, G. D., Insabato, L., & Zullo, F. (2019) · Acta Obstetricia Et Gynecologica Scandinavica · doi:10.1111/aogs.13586 · Cited by 91
Ultrasound, CT, MRI, or PET-CT for staging and re-staging of adults with cutaneous melanoma
Dinnes, J., di Ruffano, L. F., Takwoingi, Y., Cheung, S. T., Nathan, P., Matin, R., Chuchu, N., Chan, S. A., Durack, A., Bayliss, S. E., et al. (2019) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd012806.pub2 · Cited by 108
Self-citationStandalone performance of artificial intelligence for upper GI neoplasia: a meta-analysis
Arribas, J., Antonelli, G., Frazzoni, L., Fuccio, L., Ebigbo, A., van der Sommen, F., Ghatwary, N., Palm, C., Coimbra, M. T., Renna, F., et al. (2020) · Gut · doi:10.1136/gutjnl-2020-321922 · Cited by 95
Subsoontorn, P., Lohitnavy, M., & Kongkaew, C. (2020) · Scientific Reports · doi:10.1038/s41598-020-79237-7 · Cited by 91
Diagnostic value of [18F]FDG-PET/CT in polymyalgia rheumatica: a systematic review and meta-analysis
van der Geest, K. S. M., Treglia, G., Glaudemans, A. W. J. M., Brouwer, E., Jamar, F., Slart, R. H. J. A., & Gheysens, O. S. (2020) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-020-05162-6 · Cited by 89
Neindre, A. L., Philippart, F., Luperto, M., Wormser, J., Morel, J., Aho, S., Mongodi, S., Mojoli, F., & Bouhemad, B. (2021) · International Journal of Nursing Studies · doi:10.1016/j.ijnurstu.2021.103890 · Cited by 94
Ahern, D. P., McDonnell, J. M., Riffault, M., Evans, S., Wagner, S. C., Vaccaro, A. R., Hoey, D. A., & Butler, J. S. (2021) · The Spine Journal · doi:10.1016/j.spinee.2021.03.008 · Cited by 93
Parenti, S. I., Fiordelli, A., Bartolucci, M. L., Martina, S., D’Antò, V., & Bonetti, G. A. (2021) · Sleep Medicine Reviews · doi:10.1016/j.smrv.2021.101464 · Cited by 96
Qu, Y., Ma, Y., Huang, Y., Ou, Y., Shen, X., Chen, S.-D., Dong, Q., Tan, L., & Yu, J. (2021) · Neuroscience & Biobehavioral Reviews · doi:10.1016/j.neubiorev.2021.07.007 · Cited by 94
Bracale, U. M., Corcione, F., Neola, D., Castiglioni, S., Cavallaro, G., Stabilini, C., Botteri, E., Sodo, M., Imperatore, N., & Peltrini, R. (2021) · Hernia · doi:10.1007/s10029-021-02487-5 · Cited by 85
Xpert® MTB/RIF assay for extrapulmonary tuberculosis and rifampicin resistance
Kohli, M., Schiller, I., Dendukuri, N., Ryan, H., Dheda, K., Denkinger, C. M., Schumacher, S. G., & Steingart, K. R. (2017) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd012768 · Cited by 84
A systematic review of microbiome-derived biomarkers for early colorectal cancer detection
Zwezerijnen-Jiwa, F. H., Sivov, H., Paizs, P., Zafeiropoulou, K., & Kinross, J. K. (2022) · Neoplasia · doi:10.1016/j.neo.2022.100868 · Cited by 94
Amyloid‐β PET in Alzheimer's disease: A systematic review and Bayesian meta‐analysis
Ruan, D., & Sun, L. (2023) · Brain and Behavior · doi:10.1002/brb3.2850 · Cited by 74
Triage and Diagnostic Accuracy of Online Symptom Checkers: Systematic Review
Sasco, E. R., El-Osta, A. A. R., Alaa, A., Webber, I., Karki, M., Asmar, M. L. E., Purohit, K., Painter, A., & Hayhoe, B. W. J. (2023) · Journal of Medical Internet Research · doi:10.2196/43803 · Cited by 105
“…the risk of bias and applicability concerns using a revised version of the Quality Assessment of Diagnostic Accuracy Studies-2 (QUADAS-2) tool [28] for the domains of patient selection, performance of the index test, performance of the reference test, and flow and timing (for risk of bias…”
Cardiac Computed Tomography for Quantification of Myocardial Extracellular Volume Fraction
Han, D., Lin, A., Kuronuma, K., Gransar, H., Dey, D., Friedman, J. D., Berman, D. S., & Tamarappoo, B. K. (2023) · JACC. Cardiovascular imaging · doi:10.1016/j.jcmg.2023.03.021 · Cited by 92
Lian, R., Liu, Q., Jiang, G., Zhang, X., Tang, H., Lü, J., & Yang, M. J. (2023) · Ageing Research Reviews · doi:10.1016/j.arr.2023.102148 · Cited by 91
Large language model use in clinical oncology
Carl, N., Schramm, F., Haggenmüller, S., Kather, J. N., Hetz, M. J., Wies, C., Michel, M. S., Wessels, F., & Brinker, T. J. (2024) · npj Precision Oncology · doi:10.1038/s41698-024-00733-4 · Cited by 80
“Weaddressedthisgap withthedevelopmentofourevaluationframework,whichisbasedonthe principlesofQUADAS-2 11 .”
BackgroundAn Update of the Systematic Assessment of the Diagnostic Accuracy of Lumbar Facet Joint Nerve Blocks
Falco, F. J. E., Manchikanti, L., Datta, S., Sehgal, N., Geffert, S., Onyewu, O., Singh, V., Bryce, D. A., Benyamin, R. M., Tt, S., et al. (2012) · Pain Physician · doi:10.36076/ppj.2012/15/e869 · Cited by 95
Deng, S., Zhang, W., Zhang, B., Chen, Y., Li, J., & Wu, Y. (2015) · PLoS ONE · doi:10.1371/journal.pone.0129028 · Cited by 85
Hallworth, M. J., Epner, P. L., Ebert, C., Fantz, C. R., Faye, S., Higgins, T., Kilpatrick, E. S., Li, W., Rana, S. V., & Vanstapel, F. J. L. A. (2015) · Clinical Chemistry · doi:10.1373/clinchem.2014.232629 · Cited by 100
Nakhjavan-Shahraki, B., Yousefifard, M., Ataei, N., Baikpour, M., Ataei, F., Bazargani, B., Abbasi, A., Ghelichkhani, P., Javidilarijani, F., & Hosseini, M. (2017) · BMC Nephrology · doi:10.1186/s12882-017-0539-0 · Cited by 96
Diagnostic accuracy of clinical tools for assessment of acute stroke: a systematic review
Antipova, D., Eadie, L. H., Macaden, A. S., & Wilson, P. (2019) · BMC Emergency Medicine · doi:10.1186/s12873-019-0262-1 · Cited by 85
Meccariello, G., Cammaroto, G., Montevecchi, F., Hoff, P. T., Spector, M. E., Negm, H., Shams, M., Bellini, C., Zeccardo, E., & Vicini, C. (2017) · European Archives of Oto-Rhino-Laryngology · doi:10.1007/s00405-016-4113-3 · Cited by 84
Circulating MicroRNAs as Biomarkers for Acute Ischemic Stroke: A Systematic Review
Dewdney, B., Trollope, A. F., Moxon, J. V., Manapurathe, D. T., Biroš, E., & Golledge, J. (2017) · Journal of Stroke and Cerebrovascular Diseases · doi:10.1016/j.jstrokecerebrovasdis.2017.09.058 · Cited by 85
Diagnostic accuracy of serum inflammatory markers in late fracture-related infection
van den Kieboom, J., Bosch, P. G., Plate, J. D. J., IJpma, F. F. A., Küehl, R., McNally, M., Metsemakers, W., & Govaert, G. A. M. (2018) · The Bone & Joint Journal · doi:10.1302/0301-620x.100b12.bjj-2018-0586.r1 · Cited by 84
Martinez-Portilla, R. J., López‐Félix, J., Hawkins-Villarreal, A., Villafán-Bernal, J. R., y Miño, F. P., Figueras, F., & BORRELL, A. (2019) · Ultrasound in Obstetrics and Gynecology · doi:10.1002/uog.20273 · Cited by 89
Calvani, M., Bianchi, A., Reginelli, C., Peresso, M., & Testa, A. (2019) · Medicina · doi:10.3390/medicina55100651 · Cited by 74
SARS-CoV-2 and the role of fomite transmission: a systematic review
Onakpoya, I., Heneghan, C. J., Spencer, E. A., Brassey, J., Plüddemann, A., Evans, D. H., Conly, J. M., & Jefferson, T. (2021) · F1000Research · doi:10.12688/f1000research.51590.3 · Cited by 84
Woods, C. R., Bradley, J. S., Chatterjee, A., Kronman, M. P., Arnold, S. R., Robinson, J. L., Copley, L. A., Arrieta, A. C., Fowler, S. L., Harrison, C., et al. (2023) · Journal of the Pediatric Infectious Diseases Society · doi:10.1093/jpids/piad089 · Cited by 92
Martín, D., Johns, C., Sorrell, L., Healy, E., Phull, M., Olusanya, O., Peters, M. J., & Fabes, J. (2024) · British Journal of Anaesthesia · doi:10.1016/j.bja.2024.01.023 · Cited by 97
“13”
Harnan, S., Tappenden, P., Essat, M., Gomersall, T., Minton, J., Wong, R., Pavord, I. D., Everard, M. L., & Lawson, R. A. (2015) · Health Technology Assessment · doi:10.3310/hta19820 · Cited by 94
Tanis, W., Habets, J., van den Brink, R. B. A., Symersky, P., Budde, R. P. J., & Chamuleau, S. A. J. (2013) · European Heart Journal - Cardiovascular Imaging · doi:10.1093/ehjci/jet127 · Cited by 84
Prevalence and underlying causes of dyspnoea in older people: a systematic review
van Mourik, Y., Rutten, F. H., Moons, K. G. M., Bertens, L. C. M., Hoes, A. W., & Reitsma, J. B. (2014) · Age and Ageing · doi:10.1093/ageing/afu001 · Cited by 84
Self-citationCT in Adults: Systematic Review and Meta-Analysis of Interpretation Discrepancy Rates
Wu, M. Z., McInnes, M. D. F., Macdonald, D. B., Kielar, A. Z., & Duigenan, S. (2013) · Radiology · doi:10.1148/radiol.13131114 · Cited by 84
Diagnostic properties of ultrasound of major salivary glands in Sjögren's syndrome: a meta‐analysis
Delli, K., Dijkstra, P., Stel, A., Bootsma, H., Vissink, A., & Spijkervet, F. (2015) · Oral Diseases · doi:10.1111/odi.12349 · Cited by 90
Diffusion-weighted imaging in head and neck squamous cell carcinomas: A systematic review
Driessen, J. P., van Kempen, P. M. W., van der Heijden, G. J. M. G., Philippens, M. E. P., Pameijer, F. A., Stegeman, I., Terhaard, C. H. J., Janssen, L. M., & Grolman, W. (2013) · Head & Neck · doi:10.1002/hed.23575 · Cited by 84
Metadata
- Authors
- Whiting, P. F., Rutjes, A. W. S., Westwood, M. E., Mallett, S., Deeks, J. J., Reitsma, J. B., Leeflang, M. M. G., Sterne, J. A. C., Bossuyt, P. M. M., & the QUADAS-2 Group*
- Affiliations
- University of Bern (CH)
- Corresponding author
- Whiting, Penny F.
- ORCID
- Venue
- Annals of Internal Medicine
- Publisher
- American College of Physicians
- Published
- 2011-10-18
- Volume
- 155
- Issue
- 8
- Pages
- 529-536
- ISSN
- 0003-4819 (ISSN-L)
- 1539-3704
- OpenAlex
- W2107638293
- Semantic Scholar
- 8a5d0b5a9271ea14bcb8479bc32d3844a80655b9
- Cited by
- 14,199
- References
- 18
- Citations by year
- 2026: 1484 · 2025: 1569 · 2024: 1524 · 2023: 1305 · 2022: 1420 · 2021: 1514 · 2020: 1245 · 2019: 955 · 2018: 767 · 2017: 637 · 2016: 580 · 2015: 528 · 2014: 363 · 2013: 217 · 2012: 75
- FWCI
- 224.36
- Type
- journal article
- Language
- en
- Open access
- green
- hdl.handle.net
- Licence
- cc-by
- www.acpjournals.org/journal/aim/text-and-data-mining (tdm)
- Locations
- Annals of Internal Medicine (publishedVersion)
- PubMed (publishedVersion)
- Pure Amsterdam UMC (publishedVersion)
- Data Archiving and Networked Services (DANS) (submittedVersion)
- Florence Research (University of Florence) (submittedVersion)
- IRIS UNIMORE (University of Modena and Reggio Emilia) (submittedVersion, cc-by)
- University of Birmingham Research Portal (University of Birmingham) (submittedVersion)
- Bristol Research (University of Bristol) (submittedVersion)
- Funders
- Cancer Research UK
- Topics
- Social Sciences › Decision Sciences › Statistics, Probability and Uncertainty › Meta-analysis and systematic reviews
- Physical Sciences › Mathematics › Statistics and Probability › Statistical Methods in Epidemiology
- Health Sciences › Medicine › Public Health, Environmental and Occupational Health › Clinical practice guidelines implementation
- Keywords
- QUADAS-2, diagnostic accuracy studies, quality assessment, risk of bias, applicability, patient selection, index tests, reference materials, flowcharts, systematic reviews
- MeSH terms
- Diagnosis, Humans, Quality Control, Surveys and Questionnaires, Reference Standards, Review Literature as Topic, Time Factors, Bias, Patient Selection, Evidence-Based Medicine
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
A language model drew the claims from the paper on 2026-11-23, under version 3 of the claim definition (model deepseek-v4.1-flash, prompt extract-v3).
A second model labelled each claim on 2026-11-23 (model jev-1.13-20260917, definition revision gold-guideline-v0.2).
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.