QUADAS-2: A Revised Tool for the Quality Assessment of Diagnostic Accuracy Studies
Open accessThe DOI matches its Crossref record; 18 of the 18 references it cites were found in a registry or an index; none of the 21 sources its claims cite is checked for support yet.
Abstract
In 2003, the QUADAS tool for systematic reviews of diagnostic accuracy studies was developed. Experience, anecdotal reports, and feedback suggested areas for improvement; therefore, QUADAS-2 was developed. This tool comprises 4 domains: patient selection, index test, reference standard, and flow and timing. Each domain is assessed in terms of risk of bias, and the first 3 domains are also assessed in terms of concerns regarding applicability. Signalling questions are included to help judge risk of bias. The QUADAS-2 tool is applied in 4 phases: summarize the review question, tailor the tool and produce review-specific guidance, construct a flow diagram for the primary study, and judge bias and applicability. This tool will allow for more transparent rating of bias and applicability of primary diagnostic accuracy studies.
Overview
CoChat Summary
TL;DR
QUADAS-2 is a revised tool for assessing risk of bias and applicability in diagnostic accuracy studies, developed through a 4-stage evidence-based consensus process. It replaces the original QUADAS “yes/no/unclear” quality rating with domain-level judgments of low, high, or unclear risk of bias and concerns about applicability.
Key findings
- QUADAS-2 separates “quality” into risk of bias and concerns regarding applicability, defining quality as the degree to which diagnostic accuracy estimates avoided bias and the extent to which primary studies are applicable to the review question.
- The tool has 4 key domains—patient selection, index test, reference standard, and flow and timing—with the first 3 also assessed for applicability; it is completed in 4 phases and uses signaling questions to help judge risk of bias.
- Development drew on 4 reviews: 54 diagnostic accuracy reviews published between 2007 and 2009, structured feedback from 64 systematic reviewers who had used QUADAS, 101 studies on sources of bias and variation, and 8 studies evaluating QUADAS; a 1-day consensus meeting had 24 attendees, and piloting occurred in 5 reviews.
- Interrater reliability varied considerably, with better agreement on applicability than on risk of bias; all participants preferred QUADAS-2 to the original tool, but the authors could not currently include criteria for studies comparing multiple index tests because the evidence base was insufficient.
Methods
- Tool development followed Moher and colleagues’ 4-stage approach: define the scope, review the evidence base, hold a face-to-face consensus meeting, and refine through piloting.
- A steering group of 9 experts set the scope; the consensus meeting was held on 21 September 2010 in Birmingham, United Kingdom, with 24 attendees who split into groups of 4 to 6 participants; multiple rounds of piloting used online questionnaires and other feedback, including pairs of reviewers piloting QUADAS-2 in 5 reviews.
- No primary statistical analysis was reported; the work synthesized evidence reviews, consensus decisions, and pilot feedback to produce and refine the tool.
Limitations
- Stated: the authors decided they cannot currently include criteria for assessing studies that compare multiple index tests within QUADAS-2 because of the limited evidence base on risk of bias and sources of variation in such studies, and they plan future work on this topic.
- Stated: piloting showed poor interrater reliability and problems applying the domain on comparative accuracy studies; interrater reliability varied considerably overall, with better agreement on applicability than on risk of bias.
- Evident from the text: full details of the 4 evidence reviews were to be published separately, and the main text reports no quantitative reliability estimates, referring instead to an Appendix Table.
Model-written summary. Check it against the paper before relying on it.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
0 Valid · 0 Not valid · 16 Not checked · 24 Own results and interpretations
In the paper
“In a review on anti-cyclic citrullinated peptide antibodies for diagnosing rheumatoid arthritis (10), we found that some studies enrolled consecutive participants with confirmed diagnoses. In these studies, testing for anticyclic citrullinated peptide antibody showed greater sensitivity than in studies that included patients with suspected disease but an unconfirmed diagnosis (that is, difficult-t”
§ QUADAS-2: A Revised Tool for the Quality Assessment of Diagnostic Accuracy Studies > Signaling question 2: Was a case-control design avoided? Signaling question 3: Did the study avoid inappropriate exclusions?
What the sources say
- Not matchedcites [10]
The reference list we hold has no entry [10].
plainstates an association- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Not matched
A statement the paper makes itself — it cites no source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“Studies that make inappropriate exclusions (for example, not including”
§ QUADAS-2: A Revised Tool for the Quality Assessment of Diagnostic Accuracy Studies > Signaling question 2: Was a case-control design avoided? Signaling question 3: Did the study avoid inappropriate exclusions?
hedgedstates a possible cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
None of the sources cited for this claim could be matched to a paper, so there is nothing to check it against.
In the paper
“Because the accuracy of a test may depend on where it will be used in the diagnostic pathway, review authors are asked to describe patients in terms of setting, intended use of the index test, patient presentation, and previous testing (8,9).”
§ QUADAS-2: A Revised Tool for the Quality Assessment of Diagnostic Accuracy Studies > Phase 1: Review Question
What the sources say
- Not matchedcites [8]
The reference list we hold has no entry [8].
- Not matchedcites [9]
The reference list we hold has no entry [9].
hedgedstates a possible cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Not matched
In the paper
“Development of QUADAS-2 was based on the 4-stage approach proposed by Moher and colleagues (4): define the scope, review the evidence base, hold a face-to-face consensus meeting, and refine the tool through piloting.”
§ QUADAS-2: A Revised Tool for the Quality Assessment of Diagnostic Accuracy Studies > METHODS
What the sources say
- Not matchedcites [4]
The reference list we hold has no entry [4].
plainstates a cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: unclear — It is unclear whether the paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Not matched
None of the sources cited for this claim could be matched to a paper, so there is nothing to check it against.
In the paper
“Studies enrolling participants with known disease and a control group without the condition may similarly exaggerate diagnostic accuracy (7,11).”
§ QUADAS-2: A Revised Tool for the Quality Assessment of Diagnostic Accuracy Studies > Signaling question 2: Was a case-control design avoided? Signaling question 3: Did the study avoid inappropriate exclusions?
What the sources say
- Not matchedcites [7]
The reference list we hold has no entry [7].
- Not matchedcites [11]
The reference list we hold has no entry [11].
hedgedstates a possible cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Not matched
10 more claims
Create a free account to see all 40 claims and every source verdict.
- Probably not a substantial claim. 19
- It may state two separate claims as one. 16
- The quote only partly states this claim. 2
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“We assessed the study-level risk of bias with the QUADAS-2 tool”
In the citing paper
“We developed a revised risk-of-bias assessment tool to address these issues, incorporate advances in assessment of risk of bias used in other recently developed tools, 9 10 and integrate recent developments in estimation of intervention effects from randomised trials. 11”
From RoB 2: a revised tool for assessing risk of bias in randomised trials (2019) · cites this paper as [10]
In the citing paper
“Two reviewers independently assessed the quality of the included studies with the Quality Assessment of Diagnostic Accuracy Studies (Quadas-2) [33].”
From High-standard predictive equations for estimating body composition using bioelectrical impedance analysis: a systematic review (2024) · cites this paper as [33]
In the citing paper
“The quality of the selected studies was rigorously assessed using the Checklist for Artificial Intelligence in Medical Imaging (CLAIM) alongside the Quality Assessment of Diagnostic Accuracy Studies-2 (QUADAS-2).23,24”
From Artificial Intelligence Detection and Segmentation Models: A Systematic Review and Meta-Analysis of Brain Tumors in Magnetic Resonance Imaging (2024) · cites this paper as [24]
In the citing paper
“The methodological quality of each selected study was assessed according to the Quality Assessment of Diagnostic Accuracy Studies (QUADAS-2) checklist [15]”
From The diagnostic accuracy of digital, infrared and mercury-in-glass thermometers in measuring body temperature: a systematic review and network meta-analysis (2021) · cites this paper as [15]
20 more claims about this paper
Create a free account to see every claim other papers make about this one.
Citations
Cites
The Cochrane Collaboration's tool for assessing risk of bias in randomised trials
Higgins, J. P. T., Altman, D. G., Gotzsche, P. C., Juni, P., Moher, D., Oxman, A. D., Savovic, J., Schulz, K. F., Weeks, L., Sterne, J. A. C., et al. (2011) · BMJ · doi:10.1136/bmj.d5928 · Cited by 33,817
Self-citationWhiting, P., Rutjes, A. W., Reitsma, J. B., Bossuyt, P. M., & Kleijnen, J. (2003) · BMC Medical Research Methodology · doi:10.1186/1471-2288-3-25 · Cited by 3,592
Self-citationThe Hazards of Scoring the Quality of Clinical Trials for Meta-analysis
Jüni, P. (1999) · JAMA · doi:10.1001/jama.282.11.1054 · Cited by 1,981
Empirical evidence of design-related bias in studies of diagnostic tests.
Lijmer, J. G. (1999) · JAMA · doi:10.1001/jama.282.11.1061 · Cited by 1,861 · cited 2×
“Studies enrolling participants with known disease and a control group without the condition may similarly exaggerate diagnostic accuracy (7, 11).”
BackgroundGuidance for Developers of Health Research Reporting Guidelines
Moher, D., Schulz, K. F., Simera, I., & Altman, D. G. (2010) · PLoS Medicine · doi:10.1371/journal.pmed.1000217 · Cited by 1,437
Systematic Reviews of Diagnostic Test Accuracy
Leeflang, M. M. G., Deeks, J. J., Gatsonis, C., & Bossuyt, P. M. M. (2008) · Annals of Internal Medicine · doi:10.7326/0003-4819-149-12-200812160-00008 · Cited by 1,124
Self-citationSources of Variation and Bias in Studies of Diagnostic Accuracy: A Systematic Review
Whiting, P., Rutjes, A. W. S., Reitsma, J. B., Glas, A. S., Bossuyt, P. M. M., & Kleijnen, J. (2004) · Annals of Internal Medicine · doi:10.7326/0003-4819-140-3-200402030-00010 · Cited by 798 · cited 4×
“The third review was an update on sources of bias and variation in diagnostic accuracy studies that included 101 studies (7).”
BackgroundInfluentialSelf-citationEvaluation of QUADAS, a tool for the quality assessment of diagnostic accuracy studies
Whiting, P. F., Weswood, M. E., Rutjes, A. W., Reitsma, J. B., Bossuyt, P. N., & Kleijnen, J. (2006) · BMC Medical Research Methodology · doi:10.1186/1471-2288-6-9 · Cited by 769
Self-citationLeeflang, M. M. G., Moons, K. G. M., Reitsma, J. B., & Zwinderman, A. H. (2008) · Clinical Chemistry · doi:10.1373/clinchem.2007.096032 · Cited by 346 · cited 1×
“Test performance is likely to be poorer in an independent sample of patients in whom the same threshold is used (12).”
BackgroundSelf-citationNo role for quality scores in systematic reviews of diagnostic accuracy studies
Whiting, P., Harbord, R., & Kleijnen, J. (2005) · BMC Medical Research Methodology · doi:10.1186/1471-2288-5-19 · Cited by 337
Self-citation
Cited by
Items 1,601–1,700 of 14,770
Furuse, M., Nonoguchi, N., Yamada, K., Shiga, T., Combes, J., Ikeda, N., Kawabata, S., Kuroiwa, T., & Miyatake, S. (2019) · Radiation Oncology · doi:10.1186/s13014-019-1228-x · Cited by 80
Wu, H. M., Xu, T., Wang, X., Yu, Y., Fan, Z.-Y., Li, D.-X., Luo, L., Yang, X.-C., Jiao, W., & Niu, H. (2019) · The World Journal of Men s Health · doi:10.5534/wjmh.180124 · Cited by 85
Tavaziva, G., Harris, M., Abidi, S. K., Geric, C., Breuninger, M., Dheda, K., Esmail, A., Muyoyeta, M., Reither, K., Majidulla, A., et al. (2022) · Clinical Infectious Diseases · doi:10.1093/cid/ciab639 · Cited by 79
Komolafe, O., Pereira, S. P., Davidson, B. R., & Gurusamy, K. S. (2017) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd012645 · Cited by 79
Outcome prediction in disorders of consciousness: the role of coma recovery scale revised
Lucca, L. F., Lofaro, D., Pignolo, L., Leto, E., Ursino, M., Cortese, M. D., Conforti, D., Tonin, P., & Cerasa, A. (2019) · BMC Neurology · doi:10.1186/s12883-019-1293-7 · Cited by 79
Pfeffer, D. A., Ley, B., Howes, R. E., Adu, P., Alam, M. S., Bansil, P., Boum, Y., Brito, M. A. M., Charoenkwan, P., Clements, A., et al. (2020) · PLoS Medicine · doi:10.1371/journal.pmed.1003084 · Cited by 89
Granberg, T., Moridi, T., Brand, J. S., Neumann, S., Hlavica, M., Piehl, F., & Ineichen, B. V. (2020) · Journal of Neurology · doi:10.1007/s00415-020-09971-5 · Cited by 83
MEKLIN, J., Syrjänen, K. J., & Eskelinen, M. J. (2020) · Anticancer Research · doi:10.21873/anticanres.14349 · Cited by 85
Boreak, N. M. (2020) · The Journal of Contemporary Dental Practice · doi:10.5005/jp-journals-10024-2894 · Cited by 79
Bom, W. J., Bolmers, M. D. M., Gans, S. L., van Rossem, C. C., van Geloven, A. A. W., Bossuyt, P. M., Stoker, J., & Boermeester, M. A. (2020) · BJS Open · doi:10.1093/bjsopen/zraa030 · Cited by 93
Self-citationJian, A., Jang, K., Manuguerra, M., Liu, S., MAGNUSSEN, J. S., & Ieva, A. D. (2021) · Neurosurgery · doi:10.1093/neuros/nyab103 · Cited by 87
Aletreby, W., Alharthy, A. M., Brindley, P. G., Kutsogiannis, D. J., Faqihi, F. A., Alzayer, W., Balhahmar, A., Soliman, I., Hamido, H. M., Alqahtani, S. A., et al. (2021) · Journal of Ultrasound in Medicine · doi:10.1002/jum.15732 · Cited by 89
Riera, S. A., Marín, S., Serra‐Prat, M., Tomsen, N., Arreola, V., Ortega, O., Walshe, M., & Clavé, P. (2021) · Foods · doi:10.3390/foods10081900 · Cited by 88
Yu, S., Zhang, H., & Li, H. (2021) · Journal of the American Heart Association · doi:10.1161/jaha.121.022505 · Cited by 90
Walsh, T., Warnakulasuriya, S., Lingen, M. W., Kerr, A. R., Ogden, G. R., Glenny, A., & Macey, R. (2021) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd010173.pub3 · Cited by 111
Noventa, M., Saccardi, C., Litta, P., Vitagliano, A., D’Antona, D., Abdulrahim, B., Duncan, A., Alexander-Sefre, F., Aldrich, C. J., Quaranta, M., et al. (2015) · Fertility and Sterility · doi:10.1016/j.fertnstert.2015.05.002 · Cited by 91
Diagnosing Significant PDA Using Natriuretic Peptides in Preterm Neonates: A Systematic Review
Kulkarni, M., Gokulakrishnan, G., Price, J. F., Fernandes, C. J., Leeflang, M., & Pammi, M. (2015) · PEDIATRICS · doi:10.1542/peds.2014-1995 · Cited by 88
Self-citationThe efficacy of bedside chest ultrasound: from accuracy to outcomes
Hew, M. J., & Tay, T. R. (2016) · European Respiratory Review · doi:10.1183/16000617.0047-2016 · Cited by 87
Cimino, S., Reale, G., Castelli, T., Favilla, V., Giardina, R., Russo, G. I., Privitera, S., & Morgia, G. (2017) · Scandinavian Journal of Urology · doi:10.1080/21681805.2017.1332680 · Cited by 79
Wouthuyzen‐Bakker, M., Benito, N., & Soriano, À. (2017) · Journal of Clinical Microbiology · doi:10.1128/jcm.00640-17 · Cited by 81
Song, J., Huang, J., Huang, H., Liu, S., & Luo, Y. (2017) · Clinics and Research in Hepatology and Gastroenterology · doi:10.1016/j.clinre.2017.11.002 · Cited by 79
The diagnostic accuracy of presepsin in neonatal sepsis: a meta-analysis
Bellos, I., Fitrou, G., Pergialiotis, V., Thomakos, N., Perrea, D. N., & Daskalakis, G. (2018) · European Journal of Pediatrics · doi:10.1007/s00431-018-3114-1 · Cited by 87
Rijs, K., Klimek, M., Boer, M. S., Biesheuvel, K., & Harhangi, B. S. (2019) · World Neurosurgery · doi:10.1016/j.wneu.2019.01.007 · Cited by 87
Connolly, M. J., McInnes, M. D. F., El-Khodary, M., McGrath, T. A., & Schieda, N. (2017) · European Radiology · doi:10.1007/s00330-017-4785-0 · Cited by 78
Clinical risk scores for predicting stroke-associated pneumonia: A systematic review
Kishore, A. K., Vail, A., Bray, B., Chamorro, Á., Napoli, M. D., Kalra, L., Langhorne, P., Montaner, J., Roffe, C., Rudd, A. G., et al. (2016) · European Stroke Journal · doi:10.1177/2396987316651759 · Cited by 79
Catarino, R., Schäfer, S., Vassilakos, P., Petignat, P., & Arbyn, M. (2017) · BJOG An International Journal of Obstetrics & Gynaecology · doi:10.1111/1471-0528.14783 · Cited by 85
Kroll, C., Mastroeni, S. S. D. B. S., Czarnobay, S. A., Ekwaru, J. P., Veugelers, P. J., & Mastroeni, M. F. (2017) · Annals of Human Biology · doi:10.1080/03014460.2017.1390153 · Cited by 78
Pepsin in saliva as a diagnostic biomarker in laryngopharyngeal reflux: a meta-analysis
Wang, J., Zhao, Y., Ren, J., & Xu, Y. (2017) · European Archives of Oto-Rhino-Laryngology · doi:10.1007/s00405-017-4845-8 · Cited by 78
Fernando, S. M., Tran, A., Cheng, W., Rochwerg, B. N., Taljaard, M., Thiruganasambandamoorthy, V., Kyeremanteng, K., & Perry, J. J. (2018) · Academic Emergency Medicine · doi:10.1111/acem.13649 · Cited by 98
Klanjšek, P., Pajnkihar, M., Varda, N. M., & Povalej, P. (2019) · BMJ Open · doi:10.1136/bmjopen-2018-025444 · Cited by 90
Imaging for Neuroprognostication After Cardiac Arrest: Systematic Review and Meta-analysis
Soto, C. L., Dragoi, L., Heyn, C., Kramer, A. H., Pinto, R. L., Adhikari, N. K. J., & Scales, D. C. (2019) · Neurocritical Care · doi:10.1007/s12028-019-00842-0 · Cited by 78
Surov, A., Meyer, H., & Wienke, A. (2019) · BMC Cancer · doi:10.1186/s12885-019-6201-4 · Cited by 85
Systematic Review: Gastrointestinal Ultrasound Scoring Indices for Inflammatory Bowel Disease
Goodsall, T. M., Nguyen, T. M., Parker, C. E., Ma, C., Andrews, J. M., Jairath, V., & Bryant, R. V. (2020) · Journal of Crohn s and Colitis · doi:10.1093/ecco-jcc/jjaa129 · Cited by 81
Gottlieb, M. A., Avila, J. O., Chottiner, M., & Peksa, G. D. (2020) · Annals of Emergency Medicine · doi:10.1016/j.annemergmed.2020.01.004 · Cited by 88
Oliveira, M., Guittet, L., Hamon, M., & Hamon, M. (2020) · Radiology Cardiothoracic Imaging · doi:10.1148/ryct.2020190189 · Cited by 87
Lee, S., Kim, Y., Shin, J., Hwang, S. H., Roh, Y. H., Chung, Y. E., & Choi, J. (2020) · Journal of the American College of Radiology · doi:10.1016/j.jacr.2020.06.005 · Cited by 90
Ocular Demodex : a systematic review of the clinical literature
Britten‐Jones, A. C., Müntz, A., Wang, M. T. M., Craig, J. P., & Downie, L. E. (2020) · Ophthalmic and Physiological Optics · doi:10.1111/opo.12691 · Cited by 87
“For Level II diagnostic-test accuracy studies, risk of bias was assessed using the QUADAS-2 tool.(22) We had intended to assess the risk of bias of prognostic studies using the QUIPS tool, however there were no eligible studies.”
Zhong, J., Hu, Y., Si, L., Jia, G., Xing, Y., Zhang, H., & Yao, W. (2020) · European Radiology · doi:10.1007/s00330-020-07221-w · Cited by 80
“The eligible articles were assessed by the RQS for methodological quality [9] and by the Quality Assessment of Diagnostic Accuracy Studies (QUADAS-2) tool for the risk of bias and concern of application [19].”
MethodPark, S., & Kwak, M.-J. (2020) · Clinical Gerontologist · doi:10.1080/07317115.2020.1839992 · Cited by 84
Vengesai, A., Midzi, H., Kasambala, M., Mutandadzi, H., Mduluza-Jokonya, T. L., Rusakaniko, S., Mutapi, F., Naicker, T., & Mduluza, T. (2021) · Systematic Reviews · doi:10.1186/s13643-021-01689-3 · Cited by 82
Castellana, M., Donghia, R., Guerra, V., Procino, F., Lampignano, L., Castellana, F., Zupo, R., Sardone, R., De Pergola, G., Romanelli, F., et al. (2021) · Journal of Clinical Medicine · doi:10.3390/jcm10091877 · Cited by 77
Artificial intelligence in the diagnosis of multiple sclerosis: A systematic review
Nabizadeh, F., Masrouri, S., Ramezannezhad, E., Ghaderi, A., Sharafi, A. M., Soraneh, S., & Moghadasi, A. N. (2022) · Multiple Sclerosis and Related Disorders · doi:10.1016/j.msard.2022.103673 · Cited by 84
Peri, A. M., Ling, W., Furuya‐Kanamori, L., Harris, P. N. A., & Paterson, D. L. (2022) · BMC Infectious Diseases · doi:10.1186/s12879-022-07772-x · Cited by 86
Duarte‐Rojo, A., Taouli, B. A., Leung, D. H., Levine, D., Nayfeh, T., Hasan, B., Alsawaf, Y., Saadi, S. M., Majzoub, A. M., Manolopoulos, A., et al. (2024) · Hepatology · doi:10.1097/hep.0000000000000852 · Cited by 99
Norman-Bruce, H., Umana, E., Mills, C., Mitchell, H. J., McFetridge, L., McCleary, D. F., & Waterfield, T. (2024) · The Lancet Child & Adolescent Health · doi:10.1016/s2352-4642(24)00021-x · Cited by 83
Delta radiomics: an updated systematic review
Nardone, V., Reginelli, A., Rubini, D., Gagliardi, F., Tufo, S. D., Belfiore, M. P., Boldrini, L., Desideri, I., & Cappabianca, S. (2024) · La radiologia medica · doi:10.1007/s11547-024-01853-4 · Cited by 86
“To assess the quality of the selected studies, two reviewers (VN and GV) independently employed the Radiomics Quality Score (RQS) [2] and the Quality Assessment of Diagnostic Accuracy Studies-2 (QUADAS-2) [15] tools.”
MethodPart 9: First Aid: 2015 International Consensus on First Aid Science With Treatment Recommendations
Singletary, E. M., Zideman, D. A., De Buck, E. D. J., Chang, W.-T., Jensen, J. L., Swain, J. M., Woodin, J. A., Blanchard, I. E., Herrington, R. A., Pellegrino, J. L., et al. (2015) · Circulation · doi:10.1161/cir.0000000000000278 · Cited by 76
D’Silva, K. A., Dahm, P., & Wong, C. L. (2014) · JAMA · doi:10.1001/jama.2014.5555 · Cited by 89
Continuous EEG Monitoring in Aneurysmal Subarachnoid Hemorrhage: A Systematic Review
Kondziella, D., Friberg, C. K., Wellwood, I., Reiffurth, C., Fabricius, M. E., & Dreier, J. P. (2014) · Neurocritical Care · doi:10.1007/s12028-014-0068-7 · Cited by 86
Self-Screening and Non-Physician Screening for Hypertension in Communities: A Systematic Review
Fleming, S., Atherton, H., McCartney, D., Hodgkinson, J., Greenfield, S., Hobbs, R. F., Mant, J., McManus, R. J., Thompson, M., Ward, A. M., et al. (2015) · American Journal of Hypertension · doi:10.1093/ajh/hpv029 · Cited by 79
Computed tomography (CT) angiography for confirmation of the clinical diagnosis of brain death
Taylor, T., Dineen, R. A., Gardiner, D. C., Buss, C. H., Howatson, A., & Pace, N. L. (2014) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd009694.pub2 · Cited by 78
Li, C., Zhang, Z., Zhang, P., & Liu, J. (2013) · Hepatology Research · doi:10.1111/hepr.12201 · Cited by 80
Schröer-Günther, M., Wolff, R. F., Westwood, M. E., Scheibler, F., Schürmann, C., Baumert, B. G., Sauerland, S., & Kleijnen, J. (2012) · Systematic Reviews · doi:10.1186/2046-4053-1-62 · Cited by 84
Self-citationPart 5: Acute coronary syndromes
Nikolaou, N. I., Welsford, M., Beygui, F., Bossaert, L. L., Ghaemmaghami, C. A., Nonogi, H., O’Connor, R. E., Pichel, D. R., Scott, T., Walters, D., et al. (2015) · Resuscitation · doi:10.1016/j.resuscitation.2015.07.043 · Cited by 81
Clinical examination of anterior cruciate ligament rupture: a systematic review and metaanalysis
Zhang, Y., Huang, W., Yao, Z., & Ma, L. (2016) · Acta Orthopaedica et Traumatologica Turcica · doi:10.3944/aott.2016.14.0283 · Cited by 78
Yang, Y., Liu, Y., & Shi, H. (2017) · Respiration · doi:10.1159/000468545 · Cited by 78
Amyloid-PET in sporadic cerebral amyloid angiopathy: A diagnostic accuracy meta-analysis
Charidimou, A., Farid, K., & Baron, J.-C. (2017) · Neurology · doi:10.1212/wnl.0000000000004539 · Cited by 75
Incontinence in autism spectrum disorder: a systematic review
Niemczyk, J., Wagner, C., & von Gontard, A. (2017) · European Child & Adolescent Psychiatry · doi:10.1007/s00787-017-1062-3 · Cited by 89
Wang, Z., Que, H., Suo, C., Han, Z., Tao, J., Huang, Z., Ju, X., Tan, R., & Gu, M. (2017) · Oncotarget · doi:10.18632/oncotarget.22065 · Cited by 78
Manatsathit, W., Samant, H. V., Kapur, S., Ingviya, T., Esmadi, M., Wijarnpreecha, K., & McCashland, T. M. (2018) · Journal of Gastroenterology and Hepatology · doi:10.1111/jgh.14271 · Cited by 89
Reflectance confocal microscopy for diagnosing keratinocyte skin cancers in adults
Dinnes, J., Deeks, J. J., Chuchu, N., Saleh, D. B., Bayliss, S. E., Takwoingi, Y., Davenport, C. F., Patel, L., Matin, R., O'Sullivan, C., et al. (2018) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd013191 · Cited by 97
Self-citationWalter, W. R., Samim, M., LaPolla, F. W. Z., & Gyftopoulos, S. (2019) · American Journal of Roentgenology · doi:10.2214/ajr.18.20504 · Cited by 78
Alabousi, M., Zha, N., Salameh, J., Samoilov, L., Sharifabadi, A. D., Pozdnyakov, A., Sadeghirad, B., Freitas, V., McInnes, M. D. F., & Alabousi, A. (2020) · European Radiology · doi:10.1007/s00330-019-06549-2 · Cited by 86
van Nijnatten, T. J. A., Schipper, R., Lobbes, M. B. I., Nelemans, P. J., Beets‐Tan, R. G. H., & Smidt, M. L. (2015) · European Journal of Surgical Oncology · doi:10.1016/j.ejso.2015.07.020 · Cited by 77
The value of diffusion-weighted imaging in the detection of prostate cancer: a meta-analysis
Jie, C., Rongbo, L., & Ping, T. (2014) · European Radiology · doi:10.1007/s00330-014-3201-2 · Cited by 77
Feng, Y., Liu, S., Wang, Q., Wang, L., Tang, S., Wang, J., & Lu, W. (2013) · PLoS ONE · doi:10.1371/journal.pone.0055292 · Cited by 77
Excess adiposity and survival in patients with colorectal cancer: a systematic review
Parkin, E., O'Reilly, D. A., Sherlock, D., Manoharan, P., & Renehan, A. G. (2014) · Obesity Reviews · doi:10.1111/obr.12140 · Cited by 82
Ophthalmic artery Doppler for prediction of pre‐eclampsia: systematic review and meta‐analysis
Kalafat, E., Laoreti, A., Khalil, A. A., Costa, F. D. S., & Thilaganathan, B. (2018) · Ultrasound in Obstetrics and Gynecology · doi:10.1002/uog.19002 · Cited by 88
Beishon, L., Batterham, A. P., Quinn, T. J., Nelson, C. P., Panerai, R. B., Robinson, T. G., & Haunton, V. J. (2019) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd013282.pub2 · Cited by 105
Liang, T., Roseman, E., Gao, M., & Sinert, R. H. (2019) · Pediatric Emergency Care · doi:10.1097/pec.0000000000001755 · Cited by 77
Gibelli, D. M., Dolci, C., Cappella, A., & Sforza, C. (2019) · International Journal of Oral and Maxillofacial Surgery · doi:10.1016/j.ijom.2019.10.019 · Cited by 77
Orsso, C. E., Silva, M. I. B., González, M. C., Rubin, D. A., Heymsfield, S. B., Prado, C. M. M., & Haqq, A. M. (2020) · Obesity Reviews · doi:10.1111/obr.13041 · Cited by 85
Suter, M. B., Pesapane, F., Agazzi, G. M., Gagliardi, T., Nigro, O., Bozzini, A. C., Priolo, F., Penco, S., Cassano, E., Chini, C., et al. (2020) · The Breast · doi:10.1016/j.breast.2020.06.005 · Cited by 85
Mulenga, H., Zauchenberger, C.-Z., Bunyasi, E. W., Mbandi, S. K., Mendelsohn, S. C., Kagina, B. M. N., Penn‐Nicholson, A., Scriba, T. J., & Hatherill, M. (2020) · PLoS ONE · doi:10.1371/journal.pone.0237574 · Cited by 77
Surov, A., Pech, M., Omari, J., Fischbach, F., Damm, R., Fischbach, K., Powerski, M. J., Relja, B., & Wienke, A. (2021) · Liver Cancer · doi:10.1159/000511384 · Cited by 82
Ugga, L., Perillo, T., Cuocolo, R., Stanzione, A., Romeo, V., Green, R., Cantoni, V., & Brunetti, A. (2021) · Neuroradiology · doi:10.1007/s00234-021-02668-0 · Cited by 84
Heidkamp, J., Scholte, M., Rosman, C., Manohar, S., Fütterer, J. J., & Rovers, M. M. (2021) · International Journal of Cancer · doi:10.1002/ijc.33570 · Cited by 86
Advanced Paternal Age and Sperm DNA Fragmentation: A Systematic Review
Gonzalez, D. C., Ory, J., Blachman-Braun, R., Nackeeran, S., Best, J. C., & Ramasamy, R. (2021) · The World Journal of Men s Health · doi:10.5534/wjmh.200195 · Cited by 89
“Each study was scored for their relevance and methodological quality by using the QUADAS 2 (Quality Assessment of Diagnostic Accuracy Studies 2) checklist [20].”
Gartlehner, G., Wagner, G., Affengruber, L., Chapman, A. L., Dobrescu, A. I., Klerings, I., Kaminski-Hartenthaler, A., & Spiel, A. O. (2021) · Annals of Internal Medicine · doi:10.7326/m20-5504 · Cited by 86
D‐dimer to rule out venous thromboembolism during pregnancy: A systematic review and meta‐analysis
Bellesini, M., Robert‐Ebadi, H., Combescure, C., Dedionigi, C., Gal, G. L., & Righini, M. (2021) · Journal of Thrombosis and Haemostasis · doi:10.1111/jth.15432 · Cited by 92
Brümmer, L. E., Katzenschlager, S., McGrath, S., Schmitz, S., Gaeddert, M., Erdmann, C., Bota, M., Grilli, M., Larmann, J., Weigand, M. A., et al. (2022) · PLoS Medicine · doi:10.1371/journal.pmed.1004011 · Cited by 82
Liu, K., Li, L., Ma, Y., Jiang, J., Liu, Z., Ye, Z., Liu, S., Pu, C., Chen, C., & Wan, Y. (2023) · JMIR Medical Informatics · doi:10.2196/47833 · Cited by 67
Methodological Standards for Conducting High-Quality Systematic Reviews
CASSAI, A. D., Dost, B., Tulgar, S., & Boscolo, A. (2025) · Biology · doi:10.3390/biology14080973 · Cited by 102
“For diagnostic accuracy studies, the QUADAS-2 tool is the standard [32].”
Virgone, C., D’Antonio, F., Khalil, A. A., Jonh, R., Manzoli, L., & Giuliani, S. (2015) · Ultrasound in Obstetrics and Gynecology · doi:10.1002/uog.14651 · Cited by 88
Plasma miR-221/222 Family as Novel Descriptive and Prognostic Biomarkers for Glioma
Zhang, R., Pang, B., Xin, T., Guo, H., Xing, Y., Xu, S., Feng, B., Liu, B., & Pang, Q. (2015) · Molecular Neurobiology · doi:10.1007/s12035-014-9079-9 · Cited by 80
Symptoms of Pancreatic Cancer in Primary Care: A Systematic Review
Schmidt-Hansen, M., Berendse, S., & Hamilton, W. (2016) · Pancreas · doi:10.1097/mpa.0000000000000527 · Cited by 70
The application of sonication in diagnosis of periprosthetic joint infection
Liu, H., Zhang, Y., Li, L., & Zou, H. C. (2016) · European Journal of Clinical Microbiology & Infectious Diseases · doi:10.1007/s10096-016-2778-6 · Cited by 77
Xiong, Y., Li, J., Ma, S., Ge, J., Zhou, L., Li, D., & Chen, Q. (2017) · PLoS ONE · doi:10.1371/journal.pone.0170819 · Cited by 82
The diagnostic role of microRNA-34a in breast cancer: a systematic review and meta-analysis
İmani, S., Zhang, X., Hosseinifard, H., Fu, S., & Fu, J. (2017) · Oncotarget · doi:10.18632/oncotarget.15520 · Cited by 84
The risk of bias in systematic reviews tool showed fair reliability and good construct validity
Bühn, S., Mathes, T., Prengel, P., Wegewitz, U. E., Ostermann, T., Robens, S., & Pieper, D. (2017) · Journal of Clinical Epidemiology · doi:10.1016/j.jclinepi.2017.06.019 · Cited by 82
Salineiro, F. C. S., Kobayashi‐Velasco, S., Braga, M. M., & Cavalcanti, M. G. P. (2017) · Dentomaxillofacial Radiology · doi:10.1259/dmfr.20170400 · Cited by 77
van Oort, P. M. P., Póvoa, P. M. S. R., Schnabel, R. M., Dark, P. M., Artigas, A., Bergmans, D. C. J. J., Felton, T., Coelho, L., Schultz, M. J., Fowler, S. J., et al. (2018) · Journal of Breath Research · doi:10.1088/1752-7163/aaa499 · Cited by 85
Rinaldi, S., Gilliland, J., O’Connor, C. P., Chesworth, B. M., & Madill, J. (2018) · Clinical Nutrition ESPEN · doi:10.1016/j.clnesp.2018.10.010 · Cited by 87
Gonzalo Labarca, T., Sierra‐Ruiz, M., Kheir, F. M., Folch, E. E., Majid, A., Mehta, H. J., Jantz, M. A., & Fernández-Bussy, S. (2019) · Annals of the American Thoracic Society · doi:10.1513/annalsats.201902-175oc · Cited by 89
Cohen, J. A., Trojano, M., Mowry, E. M., Uitdehaag, B. M. J., Reingold, S. C., & Marrie, R. A. (2019) · Multiple Sclerosis Journal · doi:10.1177/1352458519892555 · Cited by 84
Diagnostic accuracy of a novel lateral-flow device in invasive aspergillosis: a meta-analysis
Pan, Z., Fu, M., Zhang, J., Zhou, H., Fu, Y., & Zhou, J. (2015) · Journal of Medical Microbiology · doi:10.1099/jmm.0.000092 · Cited by 76
Kim, S.-J., Lee, S.-W., Pak, K., Kim, I.-J., & Kim, K. (2018) · The British Journal of Radiology · doi:10.1259/bjr.20170520 · Cited by 76
Carrasco-Labra, A., Lytvyn, L., Falck-Ytter, Y., Surawicz, C. M., & Chey, W. D. (2019) · Gastroenterology · doi:10.1053/j.gastro.2019.06.014 · Cited by 76
Routine laboratory testing to determine if a patient has COVID-19
Stegeman, I., Ochodo, E. A., Guleid, F., Holtman, G. A., Yang, B., Davenport, C., Deeks, J. J., Dinnes, J., Dittrich, S., Emperador, D., et al. (2020) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd013787 · Cited by 76
Self-citationMigda, B., Migda, M., Migda, M. S., & Słapa, R. Z. (2018) · European Radiology · doi:10.1007/s00330-017-5230-0 · Cited by 78
Metadata
- Authors
- Whiting, P. F., Rutjes, A. W. S., Westwood, M. E., Mallett, S., Deeks, J. J., Reitsma, J. B., Leeflang, M. M. G., Sterne, J. A. C., Bossuyt, P. M. M., & the QUADAS-2 Group*
- Affiliations
- University of Bern (CH)
- Corresponding author
- Whiting, Penny F.
- ORCID
- Venue
- Annals of Internal Medicine
- Publisher
- American College of Physicians
- Published
- 2011-10-18
- Volume
- 155
- Issue
- 8
- Pages
- 529-536
- ISSN
- 0003-4819 (ISSN-L)
- 1539-3704
- OpenAlex
- W2107638293
- Semantic Scholar
- 8a5d0b5a9271ea14bcb8479bc32d3844a80655b9
- Cited by
- 14,199
- References
- 18
- Citations by year
- 2026: 1484 · 2025: 1569 · 2024: 1524 · 2023: 1305 · 2022: 1420 · 2021: 1514 · 2020: 1245 · 2019: 955 · 2018: 767 · 2017: 637 · 2016: 580 · 2015: 528 · 2014: 363 · 2013: 217 · 2012: 75
- FWCI
- 224.36
- Type
- journal article
- Language
- en
- Open access
- green
- hdl.handle.net
- Licence
- cc-by
- www.acpjournals.org/journal/aim/text-and-data-mining (tdm)
- Locations
- Annals of Internal Medicine (publishedVersion)
- PubMed (publishedVersion)
- Pure Amsterdam UMC (publishedVersion)
- Data Archiving and Networked Services (DANS) (submittedVersion)
- Florence Research (University of Florence) (submittedVersion)
- IRIS UNIMORE (University of Modena and Reggio Emilia) (submittedVersion, cc-by)
- University of Birmingham Research Portal (University of Birmingham) (submittedVersion)
- Bristol Research (University of Bristol) (submittedVersion)
- Funders
- Cancer Research UK
- Topics
- Social Sciences › Decision Sciences › Statistics, Probability and Uncertainty › Meta-analysis and systematic reviews
- Physical Sciences › Mathematics › Statistics and Probability › Statistical Methods in Epidemiology
- Health Sciences › Medicine › Public Health, Environmental and Occupational Health › Clinical practice guidelines implementation
- Keywords
- QUADAS-2, diagnostic accuracy studies, quality assessment, risk of bias, applicability, patient selection, index tests, reference materials, flowcharts, systematic reviews
- MeSH terms
- Diagnosis, Humans, Quality Control, Surveys and Questionnaires, Reference Standards, Review Literature as Topic, Time Factors, Bias, Patient Selection, Evidence-Based Medicine
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
A language model drew the claims from the paper on 2026-11-23, under version 3 of the claim definition (model deepseek-v4.1-flash, prompt extract-v3).
A second model labelled each claim on 2026-11-23 (model jev-1.13-20260917, definition revision gold-guideline-v0.2).
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.