Abstract
In 2003, the QUADAS tool for systematic reviews of diagnostic accuracy studies was developed. Experience, anecdotal reports, and feedback suggested areas for improvement; therefore, QUADAS-2 was developed. This tool comprises 4 domains: patient selection, index test, reference standard, and flow and timing. Each domain is assessed in terms of risk of bias, and the first 3 domains are also assessed in terms of concerns regarding applicability. Signalling questions are included to help judge risk of bias. The QUADAS-2 tool is applied in 4 phases: summarize the review question, tailor the tool and produce review-specific guidance, construct a flow diagram for the primary study, and judge bias and applicability. This tool will allow for more transparent rating of bias and applicability of primary diagnostic accuracy studies.
Overview
CoChat Summary
TL;DR
QUADAS-2 is a revised tool for assessing risk of bias and applicability in diagnostic accuracy studies, developed through a 4-stage evidence-based consensus process. It replaces the original QUADAS “yes/no/unclear” quality rating with domain-level judgments of low, high, or unclear risk of bias and concerns about applicability.
Key findings
- QUADAS-2 separates “quality” into risk of bias and concerns regarding applicability, defining quality as the degree to which diagnostic accuracy estimates avoided bias and the extent to which primary studies are applicable to the review question.
- The tool has 4 key domains—patient selection, index test, reference standard, and flow and timing—with the first 3 also assessed for applicability; it is completed in 4 phases and uses signaling questions to help judge risk of bias.
- Development drew on 4 reviews: 54 diagnostic accuracy reviews published between 2007 and 2009, structured feedback from 64 systematic reviewers who had used QUADAS, 101 studies on sources of bias and variation, and 8 studies evaluating QUADAS; a 1-day consensus meeting had 24 attendees, and piloting occurred in 5 reviews.
- Interrater reliability varied considerably, with better agreement on applicability than on risk of bias; all participants preferred QUADAS-2 to the original tool, but the authors could not currently include criteria for studies comparing multiple index tests because the evidence base was insufficient.
Methods
- Tool development followed Moher and colleagues’ 4-stage approach: define the scope, review the evidence base, hold a face-to-face consensus meeting, and refine through piloting.
- A steering group of 9 experts set the scope; the consensus meeting was held on 21 September 2010 in Birmingham, United Kingdom, with 24 attendees who split into groups of 4 to 6 participants; multiple rounds of piloting used online questionnaires and other feedback, including pairs of reviewers piloting QUADAS-2 in 5 reviews.
- No primary statistical analysis was reported; the work synthesized evidence reviews, consensus decisions, and pilot feedback to produce and refine the tool.
Limitations
- Stated: the authors decided they cannot currently include criteria for assessing studies that compare multiple index tests within QUADAS-2 because of the limited evidence base on risk of bias and sources of variation in such studies, and they plan future work on this topic.
- Stated: piloting showed poor interrater reliability and problems applying the domain on comparative accuracy studies; interrater reliability varied considerably overall, with better agreement on applicability than on risk of bias.
- Evident from the text: full details of the 4 evidence reviews were to be published separately, and the main text reports no quantitative reliability estimates, referring instead to an Appendix Table.
Model-written summary. Check it against the paper before relying on it.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
0 Valid · 0 Not valid · 16 Not checked · 24 Own results and interpretations
In the paper
“In a review on anti-cyclic citrullinated peptide antibodies for diagnosing rheumatoid arthritis (10), we found that some studies enrolled consecutive participants with confirmed diagnoses. In these studies, testing for anticyclic citrullinated peptide antibody showed greater sensitivity than in studies that included patients with suspected disease but an unconfirmed diagnosis (that is, difficult-t”
§ QUADAS-2: A Revised Tool for the Quality Assessment of Diagnostic Accuracy Studies > Signaling question 2: Was a case-control design avoided? Signaling question 3: Did the study avoid inappropriate exclusions?
What the sources say
- Not matchedcites [10]
The reference list we hold has no entry [10].
plainstates an association- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Not matched
A statement the paper makes itself — it cites no source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“Studies that make inappropriate exclusions (for example, not including”
§ QUADAS-2: A Revised Tool for the Quality Assessment of Diagnostic Accuracy Studies > Signaling question 2: Was a case-control design avoided? Signaling question 3: Did the study avoid inappropriate exclusions?
hedgedstates a possible cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
None of the sources cited for this claim could be matched to a paper, so there is nothing to check it against.
In the paper
“Because the accuracy of a test may depend on where it will be used in the diagnostic pathway, review authors are asked to describe patients in terms of setting, intended use of the index test, patient presentation, and previous testing (8,9).”
§ QUADAS-2: A Revised Tool for the Quality Assessment of Diagnostic Accuracy Studies > Phase 1: Review Question
What the sources say
- Not matchedcites [8]
The reference list we hold has no entry [8].
- Not matchedcites [9]
The reference list we hold has no entry [9].
hedgedstates a possible cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Not matched
In the paper
“Development of QUADAS-2 was based on the 4-stage approach proposed by Moher and colleagues (4): define the scope, review the evidence base, hold a face-to-face consensus meeting, and refine the tool through piloting.”
§ QUADAS-2: A Revised Tool for the Quality Assessment of Diagnostic Accuracy Studies > METHODS
What the sources say
- Not matchedcites [4]
The reference list we hold has no entry [4].
plainstates a cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: unclear — It is unclear whether the paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Not matched
None of the sources cited for this claim could be matched to a paper, so there is nothing to check it against.
In the paper
“Studies enrolling participants with known disease and a control group without the condition may similarly exaggerate diagnostic accuracy (7,11).”
§ QUADAS-2: A Revised Tool for the Quality Assessment of Diagnostic Accuracy Studies > Signaling question 2: Was a case-control design avoided? Signaling question 3: Did the study avoid inappropriate exclusions?
What the sources say
- Not matchedcites [7]
The reference list we hold has no entry [7].
- Not matchedcites [11]
The reference list we hold has no entry [11].
hedgedstates a possible cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Not matched
10 more claims
Create a free account to see all 40 claims and every source verdict.
- Probably not a substantial claim. 19
- It may state two separate claims as one. 16
- The quote only partly states this claim. 2
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“We assessed the study-level risk of bias with the QUADAS-2 tool”
In the citing paper
“We developed a revised risk-of-bias assessment tool to address these issues, incorporate advances in assessment of risk of bias used in other recently developed tools, 9 10 and integrate recent developments in estimation of intervention effects from randomised trials. 11”
From RoB 2: a revised tool for assessing risk of bias in randomised trials (2019) · cites this paper as [10]
In the citing paper
“Two reviewers independently assessed the quality of the included studies with the Quality Assessment of Diagnostic Accuracy Studies (Quadas-2) [33].”
From High-standard predictive equations for estimating body composition using bioelectrical impedance analysis: a systematic review (2024) · cites this paper as [33]
In the citing paper
“The quality of the selected studies was rigorously assessed using the Checklist for Artificial Intelligence in Medical Imaging (CLAIM) alongside the Quality Assessment of Diagnostic Accuracy Studies-2 (QUADAS-2).23,24”
From Artificial Intelligence Detection and Segmentation Models: A Systematic Review and Meta-Analysis of Brain Tumors in Magnetic Resonance Imaging (2024) · cites this paper as [24]
In the citing paper
“The methodological quality of each selected study was assessed according to the Quality Assessment of Diagnostic Accuracy Studies (QUADAS-2) checklist [15]”
From The diagnostic accuracy of digital, infrared and mercury-in-glass thermometers in measuring body temperature: a systematic review and network meta-analysis (2021) · cites this paper as [15]
20 more claims about this paper
Create a free account to see every claim other papers make about this one.
Citations
Cites
The Cochrane Collaboration's tool for assessing risk of bias in randomised trials
Higgins, J. P. T., Altman, D. G., Gotzsche, P. C., Juni, P., Moher, D., Oxman, A. D., Savovic, J., Schulz, K. F., Weeks, L., Sterne, J. A. C., et al. (2011) · BMJ · doi:10.1136/bmj.d5928 · Cited by 33,817
Self-citationWhiting, P., Rutjes, A. W., Reitsma, J. B., Bossuyt, P. M., & Kleijnen, J. (2003) · BMC Medical Research Methodology · doi:10.1186/1471-2288-3-25 · Cited by 3,592
Self-citationThe Hazards of Scoring the Quality of Clinical Trials for Meta-analysis
Jüni, P. (1999) · JAMA · doi:10.1001/jama.282.11.1054 · Cited by 1,981
Empirical evidence of design-related bias in studies of diagnostic tests.
Lijmer, J. G. (1999) · JAMA · doi:10.1001/jama.282.11.1061 · Cited by 1,861 · cited 2×
“Studies enrolling participants with known disease and a control group without the condition may similarly exaggerate diagnostic accuracy (7, 11).”
BackgroundGuidance for Developers of Health Research Reporting Guidelines
Moher, D., Schulz, K. F., Simera, I., & Altman, D. G. (2010) · PLoS Medicine · doi:10.1371/journal.pmed.1000217 · Cited by 1,437
Systematic Reviews of Diagnostic Test Accuracy
Leeflang, M. M. G., Deeks, J. J., Gatsonis, C., & Bossuyt, P. M. M. (2008) · Annals of Internal Medicine · doi:10.7326/0003-4819-149-12-200812160-00008 · Cited by 1,124
Self-citationSources of Variation and Bias in Studies of Diagnostic Accuracy: A Systematic Review
Whiting, P., Rutjes, A. W. S., Reitsma, J. B., Glas, A. S., Bossuyt, P. M. M., & Kleijnen, J. (2004) · Annals of Internal Medicine · doi:10.7326/0003-4819-140-3-200402030-00010 · Cited by 798 · cited 4×
“The third review was an update on sources of bias and variation in diagnostic accuracy studies that included 101 studies (7).”
BackgroundInfluentialSelf-citationEvaluation of QUADAS, a tool for the quality assessment of diagnostic accuracy studies
Whiting, P. F., Weswood, M. E., Rutjes, A. W., Reitsma, J. B., Bossuyt, P. N., & Kleijnen, J. (2006) · BMC Medical Research Methodology · doi:10.1186/1471-2288-6-9 · Cited by 769
Self-citationLeeflang, M. M. G., Moons, K. G. M., Reitsma, J. B., & Zwinderman, A. H. (2008) · Clinical Chemistry · doi:10.1373/clinchem.2007.096032 · Cited by 346 · cited 1×
“Test performance is likely to be poorer in an independent sample of patients in whom the same threshold is used (12).”
BackgroundSelf-citationNo role for quality scores in systematic reviews of diagnostic accuracy studies
Whiting, P., Harbord, R., & Kleijnen, J. (2005) · BMC Medical Research Methodology · doi:10.1186/1471-2288-5-19 · Cited by 337
Self-citation
Cited by
Items 1,101–1,200 of 14,770
Davis, J. J., Czerniski, B., Au, A. K., Adhikari, S., Farrell, I., & Fields, J. M. (2015) · Academic Emergency Medicine · doi:10.1111/acem.12714 · Cited by 106
Li, X.-T., Sun, Y., Tang, L., Cao, K., & Zhang, X. (2015) · Colorectal Disease · doi:10.1111/codi.12909 · Cited by 106
Value of composite reference standards in diagnostic research
Naaktgeboren, C. A., Bertens, L. C. M., Smeden, M. V., Groot, J. A. H. D., Moons, K. G. M., & Reitsma, J. B. (2013) · BMJ · doi:10.1136/bmj.f5605 · Cited by 105
Self-citationSystematic Review of the Literature: Best Practices
Gupta, S., Rajiah, P., Middlebrooks, E. H., Baruah, D., Carter, B. W., Burton, K. R., Chatterjee, A. R., & Miller, M. M. (2018) · Academic Radiology · doi:10.1016/j.acra.2018.04.025 · Cited by 105
Andersson, J. K., Andernord, D., Karlsson, J., & Fridén, J. O. (2015) · Arthroscopy The Journal of Arthroscopic and Related Surgery · doi:10.1016/j.arthro.2015.04.090 · Cited by 105
Marchello, C. S., Dale, A. P., Thai, T. N., Han, D., & Ebell, M. H. (2016) · The Annals of Family Medicine · doi:10.1370/afm.1993 · Cited by 116
Puthumana, J., Ariza, X., Belcher, J. M., Graupera, I., Ginès, P., & Parikh, C. R. (2016) · Clinical Gastroenterology and Hepatology · doi:10.1016/j.cgh.2016.11.035 · Cited by 105
“We assessed the methodologic quality of studies using the Quality Assessment of Diagnostic Accuracy Studies 2 tool (Supplementary Table 1).(26)”
Levenhagen, K., Davies, C. C., Perdomo, M., Ryans, K., & Gilchrist, L. S. (2017) · Physical Therapy · doi:10.1093/ptj/pzx050 · Cited by 105
Lung ultrasound in diagnosing pneumonia in childhood: a systematic review and meta-analysis
Orso, D., Ban, A., & Guglielmo, N. (2018) · Journal of Ultrasound · doi:10.1007/s40477-018-0306-5 · Cited by 105
Subiela, J. D., Territo, A., Mercadé, A., Balañà, J., Aumatell, J., Cortez, J. F. C., Gallioli, A., González‐Padilla, D. A., Gaya, J. M., Palou, J., et al. (2020) · European Journal of Surgical Oncology · doi:10.1016/j.ejso.2020.06.024 · Cited by 105
Kuriyama, A., Jackson, J. L., & Kamei, J. (2020) · Critical Care · doi:10.1186/s13054-020-03358-8 · Cited by 117
Lim, S., Li, W., Kemper, J., Nguyen, A., Mol, B. W., & Reddy, M. (2020) · Obstetrics and Gynecology · doi:10.1097/aog.0000000000004149 · Cited by 116
Meta-Analysis of Lung Ultrasound Scores for Early Prediction of Bronchopulmonary Dysplasia
Pezza, L., Ojembarrena, A. A., Elsayed, Y., Yousef, N., Vedovelli, L., Raimondi, F., & Luca, D. D. (2022) · Annals of the American Thoracic Society · doi:10.1513/annalsats.202107-822oc · Cited by 112
Wearable cuffless blood pressure monitoring devices: a systematic review and meta-analysis
Islam, S. M. S., Chow, C. K., Daryabeygi‐Khotbehsara, R., Subedi, N., Rawstorn, J. C., Tegegne, T. K., Karmakar, C. K., Siddiqui, M. U., Lambert, G. W., & Maddison, R. (2022) · European Heart Journal - Digital Health · doi:10.1093/ehjdh/ztac021 · Cited by 115
“…was assessed by two independent reviewers (R.D. and S.M.S.I.) using the Quality Assessment of Diagnostic Accuracy Studies version 2 (QUADAS-2) tool, 29 which has been widely used in systematic reviews to evaluate the risk of bias and applicability of primary diagnostic Wearable BP devices: a…”
Habets, J., Tanis, W., Reitsma, J. B., van den Brink, R. B. A., Mali, W. P. T. M., Chamuleau, S. A. J., & Budde, R. P. J. (2015) · European Radiology · doi:10.1007/s00330-015-3605-7 · Cited by 110
Self-citationYang, X., Yang, Y., Li, Z., Chen, C., Yang, T., Wang, C., Liu, L., & Liu, S. (2015) · PLoS ONE · doi:10.1371/journal.pone.0124884 · Cited by 117
Hiscock, R. J., Kumar, D., & Simmons, S. W. (2015) · Anaesthesia and Intensive Care · doi:10.1177/0310057x1504300310 · Cited by 106
Ng, C. Y., Huang, Y.-H., Chu, C. F., Wu, T.-I., & Liu, S. (2017) · British Journal of Dermatology · doi:10.1111/bjd.15366 · Cited by 104
Flores Kim, J., McCleary, N., Nwaru, B. I., Stoddart, A., & Sheikh, A. (2018) · Allergy · doi:10.1111/all.13399 · Cited by 104
Diaphragmatic ultrasonography for predicting ventilator weaning: A meta-analysis
Li, C., Li, X., Han, H., Cui, H., Wang, G., & Wang, Z. (2018) · Medicine · doi:10.1097/md.0000000000010968 · Cited by 121
Treglia, G., Annunziata, S., Pizzuto, D. A., Giovanella, L., Prior, J. O., & Ceriani, L. (2019) · Cancers · doi:10.3390/cancers11050710 · Cited by 111
TCGA Classification of Endometrial Cancer: the Place of Carcinosarcoma
Travaglino, A., Raffone, A., Gencarelli, A., Mollo, A., Guida, M., Insabato, L., Santoro, A., Zannoni, G. F., & Zullo, F. (2020) · Pathology & Oncology Research · doi:10.1007/s12253-020-00829-9 · Cited by 104
Peanut allergy diagnosis: A 2020 practice parameter update, systematic review, and GRADE analysis
Greenhawt, M., Shaker, M. S., Wang, J., Oppenheimer, J., Sicherer, S. H., Keet, C. A., Swaggart, K., Rank, M. A., Portnoy, J. M., Bernstein, J., et al. (2020) · Journal of Allergy and Clinical Immunology · doi:10.1016/j.jaci.2020.07.031 · Cited by 108
Pillay, J., Donovan, L., Guitard, S., Zakher, B., Gates, M., Gates, A., Vandermeer, B., Bougatsos, C., Chou, R., & Hartling, L. (2021) · JAMA · doi:10.1001/jama.2021.10404 · Cited by 99
Farah, M. H., Nayfeh, T., Urtecho, M., Hasan, B., Amin, M., Sen, I., Wang, Z., Prokop, L. J., Lawrence, P. F., Gloviczki, P., et al. (2021) · Journal of Vascular Surgery Venous and Lymphatic Disorders · doi:10.1016/j.jvsv.2021.08.011 · Cited by 127
Hemmig, A. K., Gozzoli, D., Werlen, L., Ewald, H., Aschwanden, M., Blockmans, D., Brouwer, E., Buchanan, R. R. C., Camellino, D., Campochiaro, C., et al. (2022) · Seminars in Arthritis and Rheumatism · doi:10.1016/j.semarthrit.2022.152017 · Cited by 104
Krause, P. J., Auwaerter, P. G., Bannuru, R. R., Branda, J. A., Falck-Ytter, Y. T., Lantos, P. M., Lavergne, V., Meissner, H. C., Osani, M. C., Rips, J. G., et al. (2020) · Clinical Infectious Diseases · doi:10.1093/cid/ciaa1216 · Cited by 104
Avni, T., Bieber, A., Green, H., Steinmetz, T., Leibovici, L., & Paul, M. (2015) · Journal of Clinical Microbiology · doi:10.1128/jcm.02675-15 · Cited by 104
Peng, Q., Zhang, X., Ming, M., Zou, L., Shen, P., & Zhu, Y. (2017) · Oncotarget · doi:10.18632/oncotarget.16488 · Cited by 111
Zhang, X., Li, Q., Yu, Y., Yao, L.-Q., Xu, M., Zhang, Y., Zhong, Y., Chen, W., & Zhou, P. (2015) · Surgical Endoscopy · doi:10.1007/s00464-015-4494-1 · Cited by 103
“Included studies were assessed for their risk of bias and applicability using revised Quality Assessment of Diagnostic Accuracy Studies (QUADAS-2) [15].”
InfluentialNell, S., Kist, J. W., Debray, T. P. A., de Keizer, B., van Oostenbrugge, T. J., Rinkes, I. H. M. B., Valk, G. D., & Vriens, M. R. (2015) · European Journal of Radiology · doi:10.1016/j.ejrad.2015.01.003 · Cited by 114
Laparoscopy for diagnosing resectability of disease in patients with advanced ovarian cancer
Rutten, M. J., Leeflang, M., Kenter, G. G., Mol, B. W., & Buist, M. R. (2014) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd009786.pub2 · Cited by 129
Self-citationAyoub, C., Erthal, F., Abdelsalam, M. A., Murad, M. H., Wang, Z., Erwin, P. J., Hillis, G. S., Kritharides, L., & Chow, B. J. W. (2017) · Journal of cardiovascular computed tomography · doi:10.1016/j.jcct.2017.05.001 · Cited by 111
Yeh, C., Wu, C., Liu, S., & Chen, K. (2019) · Annals of Intensive Care · doi:10.1186/s13613-018-0479-2 · Cited by 103
Medical Diagnostic Tests: A Review of Test Anatomy, Phases, and Statistical Treatment of Data
Bolboaca, S. D. (2019) · Computational and Mathematical Methods in Medicine · doi:10.1155/2019/1891569 · Cited by 109
Bang, C. S., Lee, J. J., & Baik, G. H. (2020) · Journal of Medical Internet Research · doi:10.2196/21983 · Cited by 102
Hellou, M. M., Górska, A., Mazzaferri, F., Cremonini, E., Gentilotti, E., Nardo, P. D., Poran, I., Leeflang, M., Tacconelli, E., & Paul, M. (2020) · Clinical Microbiology and Infection · doi:10.1016/j.cmi.2020.11.002 · Cited by 104
Self-citationInfiltrating T-cell markers in cervical carcinogenesis: a systematic review and meta-analysis
Litwin, T. R., Irvin, S., Chornock, R. L., Sahasrabuddhe, V. V., Stanley, M., & Wentzensen, N. (2020) · British Journal of Cancer · doi:10.1038/s41416-020-01184-x · Cited by 115
Alabousi, M., Wadera, A., Al-Ghita, M. K., Al-Ghetaa, R. K., Salameh, J., Pozdnyakov, A., Zha, N., Samoilov, L., Sharifabadi, A. D., Sadeghirad, B., et al. (2020) · JNCI Journal of the National Cancer Institute · doi:10.1093/jnci/djaa205 · Cited by 117
Beniczky, S., Wiebe, S., Jeppesen, J., Tatum, W. O., Brazdil, M., Wang, Y., Herman, S. T., & Ryvlin, P. (2021) · Epilepsia · doi:10.1111/epi.16818 · Cited by 96
“For systematic assessment of risk of bias, we have adapted the items from the Quality Assessment of Diagnostic Accuracy Studies (QUADAS-2) to the specific application for this health technology assessment (Handbook, 2020; Whiting et al., 2011).”
Dong, L., Yang, Q., Zhang, R., & Wei, W. B. (2021) · EClinicalMedicine · doi:10.1016/j.eclinm.2021.100875 · Cited by 114
“[16] The QUADAS-2 scale consists of 4 aspects for risk of bias including patient selection, index test, reference standard, and fl ow & timing as well as 3 domains for applicability concerns including patient selection, index test, and reference standard.”
Kong, L., Li, Y., & Liu, Z. (2022) · Clinical Oral Investigations · doi:10.1007/s00784-022-04607-6 · Cited by 119
Ultrasound for the Diagnosis of Biliary Atresia: A Meta-Analysis
Zhou, L., Shan, Q., Tian, W., Wang, Z., Liang, J., & Xie, X. (2016) · American Journal of Roentgenology · doi:10.2214/ajr.15.15336 · Cited by 112
Byambasuren, O., Cardona, M., Bell, K., Clark, J. M., McLaws, M., & Glasziou, P. (2020) · SSRN Electronic Journal · doi:10.2139/ssrn.3586675 · Cited by 106
Hirst, J. A., McLellan, J. H., Price, C. P., English, E., Feakins, B. G., Stevens, R. J., & Farmer, A. J. (2017) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2016-0303 · Cited by 102
Kohn, C. G., Mearns, E. S., Parker, M. W., Hernández, A. V., & Coleman, C. I. (2014) · CHEST Journal · doi:10.1378/chest.14-1888 · Cited by 115
Circulating microRNAs as Biomarkers of Alzheimer’s Disease: A Systematic Review
Wu, H. Z. Y., Ong, K. L., Seeher, K., Armstrong, N. J., Thalamuthu, A., Brodaty, H., Sachdev, P., & Mather, K. (2015) · Journal of Alzheimer's Disease · doi:10.3233/jad-150619 · Cited by 99
Physical examination of the elbow, what is the evidence? A systematic literature review
Zwerus, E. L., Somford, M. P., Maissan, F., Heisen, J., Eygendaal, D. E., & van den Bekerom, M. P. J. (2017) · British Journal of Sports Medicine · doi:10.1136/bjsports-2016-096712 · Cited by 114
Validity of different tools to assess sleep bruxism: a meta‐analysis
Casett, E., Réus, J. C., Stuginski‐Barbosa, J., Porporatti, A. L., Carra, M. C., Peres, M. A., Canto, G. D. L., & Manfredini, D. (2017) · Journal of Oral Rehabilitation · doi:10.1111/joor.12520 · Cited by 102
Freeman, K., Mistry, H., Tsertsvadze, A., Royle, P., McCarthy, N. D., Taylor‐Phillips, S., Manuel, R. J., & Mason, J. M. (2017) · Health Technology Assessment · doi:10.3310/hta21230 · Cited by 112
Li, J., Chen, X., Qi, M., & Li, Y.-S. (2018) · PLoS ONE · doi:10.1371/journal.pone.0204364 · Cited by 102
High-frequency ultrasound for diagnosing skin cancer in adults
Dinnes, J., Bamber, J., Chuchu, N., Bayliss, S. E., Takwoingi, Y., Davenport, C., Godfrey, K., O'Sullivan, C., Matin, R. N., Deeks, J. J., et al. (2018) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd013188 · Cited by 97
Self-citationCarli, A. V., Abdelbary, H., Ahmadzai, N., Cheng, W., Shea, B., Hutton, B., Sniderman, J., Sanders, B., Esmaeilisaraji, L., Skidmore, B., et al. (2019) · Journal of Bone and Joint Surgery · doi:10.2106/jbjs.18.00632 · Cited by 102
Segmented filamentous bacteria: commensal microbes with potential effects on research.
Ericsson, A. C., Hagan, C. E., Davis, D. J., & Franklin, C. L. (2014) · PubMed Central · Cited by 134
QUAPAS: An Adaptation of the QUADAS-2 Tool to Assess Prognostic Accuracy Studies
Lee, J., Mulder, F. I., Leeflang, M., Wolff, R. F., Whiting, P. F., & Bossuyt, P. M. (2022) · Annals of Internal Medicine · doi:10.7326/m22-0276 · Cited by 111
Self-citationO USO DO CANABIDIOL NO TRATAMENTO DA EPILEPSIA
de Jesus, D. P., Farias, M. C., de Sousa, N. M., & Eduardo, A. M. D. L. E. N. (2022) · doi:10.22533/at.ed.9612213077 · Cited by 102
Deep learning in periodontology and oral implantology: A scoping review
Mohammad‐Rahimi, H., Motamedian, S. R., Pirayesh, Z., Haiat, A., Zahedrozegar, S., Mahmoudinia, E., Rohban, M. H., Krois, J., Lee, J., & Schwendicke, F. (2022) · Journal of Periodontal Research · doi:10.1111/jre.13037 · Cited by 91
Tooth automatic segmentation from CBCT images: a systematic review
Polizzi, A., Quinzi, V., Ronsivalle, V., Venezia, P., Santonocito, S., Giudice, A. L., Leonardi, R. M., & Isola, G. (2023) · Clinical Oral Investigations · doi:10.1007/s00784-023-05048-5 · Cited by 102
Fitridge, R., Chuter, V., Mills, J. L., Hinchliffe, R. J., Azuma, N., Behrendt, C., Boyko, E. J., Conte, M. S., Humphries, M. D., Kirksey, L., et al. (2023) · Journal of Vascular Surgery · doi:10.1016/j.jvs.2023.07.020 · Cited by 121
Zhao, H., Ou, L., Zhang, Z., Zhang, L., Liu, K., & Kuang, J. (2024) · European Radiology · doi:10.1007/s00330-024-10928-9 · Cited by 118
Lipinski, M. J., Baker, N. C., Escarcega, R. O., Torguson, R., Chen, F., Aldous, S. J., Christ, M., Collinson, P. O., Goodacre, S. W., Mair, J. M., et al. (2014) · American Heart Journal · doi:10.1016/j.ahj.2014.10.007 · Cited by 108
Gupta-Wright, A., Peters, J. A., Flach, C., & Lawn, S. D. (2016) · BMC Medicine · doi:10.1186/s12916-016-0603-9 · Cited by 96
Reflectance confocal microscopy for diagnosing cutaneous melanoma in adults
Dinnes, J., Deeks, J. J., Saleh, D., Chuchu, N., Bayliss, S. E., Patel, L., Davenport, C., Takwoingi, Y., Godfrey, K., Matin, R. N., et al. (2018) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd013190 · Cited by 95
Self-citationSystematic Review and Meta‐Analysis: Circulating miRNAs for Diagnosis of Hepatocellular Carcinoma
Huang, J., Liu, S., Ma, H., Yang, Y., Zhang, X., Sun, H., Zhang, X., Xu, J., & Wang, J. (2015) · Journal of Cellular Physiology · doi:10.1002/jcp.25135 · Cited by 104
Ten‐year updated meta‐analysis of the clinical characteristics of pediatric mania and hypomania
Van Meter, A. R., Burke, C., Kowatch, R. A., Findling, R. L., & Youngstrom, E. A. (2016) · Bipolar Disorders · doi:10.1111/bdi.12358 · Cited by 94
Using quality assessment tools to critically appraise ageing research: a guide for clinicians
Harrison, J. K., Reid, J., Quinn, T., & Shenkin, S. D. (2016) · Age and Ageing · doi:10.1093/ageing/afw223 · Cited by 118
Melchor, J. C., Khalil, A. A., Wing, D. A., Schleußner, E., & Surbek, D. (2018) · Ultrasound in Obstetrics and Gynecology · doi:10.1002/uog.19119 · Cited by 108
Sanders, M., Servaas, S., & Slagt, C. (2020) · Journal of Clinical Monitoring and Computing · doi:10.1007/s10877-019-00330-y · Cited by 96
Lui, K. L., Tsui, V. W. M., & Leung, W. K. (2020) · Gastrointestinal Endoscopy · doi:10.1016/j.gie.2020.06.034 · Cited by 109
Hansell, L., Milross, M., Delaney, A. P., Tian, D. H., & Ntoumenopoulos, G. (2020) · Journal of physiotherapy · doi:10.1016/j.jphys.2020.12.002 · Cited by 112
Zheng, Q., Yang, L., Zeng, B., Li, J., Guo, K., Liang, Y., & Liao, G. (2020) · EClinicalMedicine · doi:10.1016/j.eclinm.2020.100669 · Cited by 112
Duration of deafness impacts auditory performance after cochlear implantation: A meta‐analysis
Bernhard, N., Gauger, U., Ventura, E. R., Uecker, F. C., Olze, H., Knopke, S., Hänsel, T., & Coordes, A. (2021) · Laryngoscope Investigative Otolaryngology · doi:10.1002/lio2.528 · Cited by 110
Nazarian, S., Lam, K., Darzi, A. W., & Ashrafian, H. (2021) · Journal of Medical Internet Research · doi:10.2196/28974 · Cited by 117
Wei, Q., Cao, H., Shi, Y., Xu, X., & Li, T. (2022) · Journal of Biomedical Informatics · doi:10.1016/j.jbi.2022.104254 · Cited by 120
Application of artificial intelligence in the diagnosis of sleep apnea
Bazoukis, G., Bollepalli, S. C., Chung, C. T., Li, X., Tse, G., Bartley, B. L., Batool‐Anwar, S., Quan, S. F., & Armoundas, A. A. (2023) · Journal of Clinical Sleep Medicine · doi:10.5664/jcsm.10532 · Cited by 116
Abbaspour, E., Karimzadhagh, S., Monsef, A., Joukar, F., Mansour‐Ghanaei, F., & Hassanipour, S. (2024) · International Journal of Surgery · doi:10.1097/js9.0000000000001239 · Cited by 111
“Quality assessment E.A. and S.K. independently assessed the included articles using the Radiomics Quality Score (RQS) checklist [19] and the modi fi ed Quality Assessment of Diagnostic Accuracy Studies (QUADAS-2) [20] tool.”
Screening for bipolar spectrum disorders: A comprehensive meta-analysis of accuracy studies
Carvalho, A. F., Takwoingi, Y., Sales, P. M. G., Soczynska, J. K., Köhler, C. A., Freitas, T. H., Quevedo, J., Hyphantis, T. N., McIntyre, R. S., & Vieta, E. (2014) · Journal of Affective Disorders · doi:10.1016/j.jad.2014.10.024 · Cited by 116
Nuclear Imaging for Classic Fever of Unknown Origin: Meta-Analysis
Takeuchi, M., Dahabreh, I. J., Nihashi, T., Iwata, M., Varghese, G. M., & Terasawa, T. (2016) · Journal of Nuclear Medicine · doi:10.2967/jnumed.116.174391 · Cited by 109
The Biomarker S100B and Mild Traumatic Brain Injury: A Meta-analysis
Oris, C., Pereira, B., Durif, J., Simon-Pimmel, J., Castellani, C., Manzano, S., Sapin, V., & Bouvier, D. (2018) · PEDIATRICS · doi:10.1542/peds.2018-0037 · Cited by 110
Rutter, M. D., Senore, C., Bisschops, R., Domagk, D., Valori, R., Kaminski, M. F., Spada, C., Bretthauer, M., Bennett, C., Bellisario, C., et al. (2015) · Endoscopy · doi:10.1055/s-0035-1569580 · Cited by 109
Accuracy of laboratory tests for the diagnosis of Cushing syndrome
Galm, B. P., Qiao, N., Klibanski, A., Biller, B. M. K., & Tritos, N. A. (2020) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/clinem/dgaa105 · Cited by 100
Gurusamy, K. S., Giljača, V., Takwoingi, Y., Higgie, D., Poropat, G., Štimac, D., & Davidson, B. R. (2015) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd010339.pub2 · Cited by 104
Choi, S. H., Kim, K. W., Lee, J. Y., Kim, K., & Park, S. H. (2015) · Inflammatory Bowel Diseases · doi:10.1097/mib.0000000000000607 · Cited by 100
Ramos, R. F., Scalon, F. M., Scalon, M. M., & Dias, D. I. (2016) · European Journal of Surgical Oncology · doi:10.1016/j.ejso.2016.06.401 · Cited by 100
Su’a, B., Mikaere, H., Rahiri, J.-L., Bissett, I. P., & Hill, A. G. (2017) · British journal of surgery · doi:10.1002/bjs.10487 · Cited by 100
Reversible diffusion-weighted imaging lesions in acute ischemic stroke
Nagaraja, N., Forder, J. R., Warach, S. J., & Merino, J. G. (2020) · Neurology · doi:10.1212/wnl.0000000000009173 · Cited by 100
Liu, Z., Yang, Z., Gu, Y., Liu, H., & Wang, P. (2021) · PLoS ONE · doi:10.1371/journal.pone.0254059 · Cited by 115
Molecular malaria diagnostics: A systematic review and meta-analysis
Roth, J., Korevaar, D. A., Leeflang, M., & Mens, P. F. (2015) · Critical Reviews in Clinical Laboratory Sciences · doi:10.3109/10408363.2015.1084991 · Cited by 110
Self-citationNaqvi, R. M., Haider, S., Tomlinson, G., & Alibhai, S. (2015) · Canadian Medical Association Journal · doi:10.1503/cmaj.140802 · Cited by 90
Liming, B. J., Ryan, M., Mack, D., Ahmad, I., & Camacho, M. (2019) · Otolaryngology–Head and Neck Surgery · doi:10.1177/0194599818815683 · Cited by 99
Pitfalls of Systematic Reviews and Meta-Analyses in Imaging Research
McInnes, M. D. F., & Bossuyt, P. M. M. (2015) · Radiology · doi:10.1148/radiol.2015142779 · Cited by 99
Self-citationMakam, A. N., Nguyen, O. K., & Auerbach, A. D. (2015) · Journal of Hospital Medicine · doi:10.1002/jhm.2347 · Cited by 99
“*Determined by 2 independent abstractors using the revised Quality Assessment of Diagnostic Accuracy Studies revised tool.(11) Three plus signs indicate the lowest risk for bias and 1 plus sign indicates highest risk for bias.”
Bharucha, T., Rutherford, A. I., Skeoch, S., Alavi, A. A., Brown, M., Galloway, J. B., Miller, R. F., Llewelyn, M., Jenkins, N., Lambourne, J., et al. (2017) · Clinical Radiology · doi:10.1016/j.crad.2017.04.014 · Cited by 105
Kujan, O., van Schaijik, B., & Farah, C. S. (2020) · Cancers · doi:10.3390/cancers12071937 · Cited by 108
“Evaluation of the studies included in the systematic review were assessed using the Quality Assessment of Diagnostic Accuracy Studies 2 (QUADAS-2) revised tool for the quality assessment of diagnostic accuracy studies [13], and Quality In Prognosis Studies (QUIPS) for prognostic and predictive studies [14].”
Colon capsule endoscopy in colorectal cancer screening: a systematic review
Vuik, F. E. R., Nieuwenburg, S. A. V., Moen, S., Spada, C., Senore, C., Hassan, C., Pennazio, M., Rondonotti, E., Pecere, S., Kuipers, E. J., et al. (2021) · Endoscopy · doi:10.1055/a-1308-1297 · Cited by 109
Chandra, M., Rai, C. B., Kumari, N., Sandhu, V. K., Chandra, K., Krishna, M., Kota, S. H., Anand, K. S., & Oudin, A. (2022) · International Journal of Environmental Research and Public Health · doi:10.3390/ijerph19031405 · Cited by 107
Chung, C. C. Y., Hue, S. P. Y., Ng, N. Y. T., Doong, P. H. L., Chu, A. T.-W., & Chung, B. H. (2023) · Genetics in Medicine · doi:10.1016/j.gim.2023.100896 · Cited by 113
Murad, M. H., Lin, L., Chu, H., Hasan, B., Alsibai, R. A., Abbas, A. S., Mustafa, R. A., & Wang, Z. (2023) · Canadian Medical Association Journal · doi:10.1503/cmaj.221802 · Cited by 113
“8 Reviewers also extracted whether the systematic reviews explicitly discussed spectrum bias or spectrum effect as a possible modifier of diagnostic accuracy, and if the reviews conducted subgroup analyses based on prevalence.”
Huang, H.-R., Fan, L.-C., Rajbanshi, B., & Xu, J.-F. (2015) · PLOS ONE · doi:10.1371/journal.pone.0127117 · Cited by 97
Kepes, S., Bennett, A. A., & McDaniel, M. A. (2014) · Academy of Management Learning and Education · doi:10.5465/amle.2013.0193 · Cited by 114
Metadata
- Authors
- Whiting, P. F., Rutjes, A. W. S., Westwood, M. E., Mallett, S., Deeks, J. J., Reitsma, J. B., Leeflang, M. M. G., Sterne, J. A. C., Bossuyt, P. M. M., & the QUADAS-2 Group*
- Affiliations
- University of Bern (CH)
- Corresponding author
- Whiting, Penny F.
- ORCID
- Venue
- Annals of Internal Medicine
- Publisher
- American College of Physicians
- Published
- 2011-10-18
- Volume
- 155
- Issue
- 8
- Pages
- 529-536
- ISSN
- 0003-4819 (ISSN-L)
- 1539-3704
- OpenAlex
- W2107638293
- Semantic Scholar
- 8a5d0b5a9271ea14bcb8479bc32d3844a80655b9
- Cited by
- 14,199
- References
- 18
- Citations by year
- 2026: 1484 · 2025: 1569 · 2024: 1524 · 2023: 1305 · 2022: 1420 · 2021: 1514 · 2020: 1245 · 2019: 955 · 2018: 767 · 2017: 637 · 2016: 580 · 2015: 528 · 2014: 363 · 2013: 217 · 2012: 75
- FWCI
- 224.36
- Type
- journal article
- Language
- en
- Open access
- green
- hdl.handle.net
- Licence
- cc-by
- www.acpjournals.org/journal/aim/text-and-data-mining (tdm)
- Locations
- Annals of Internal Medicine (publishedVersion)
- PubMed (publishedVersion)
- Pure Amsterdam UMC (publishedVersion)
- Data Archiving and Networked Services (DANS) (submittedVersion)
- Florence Research (University of Florence) (submittedVersion)
- IRIS UNIMORE (University of Modena and Reggio Emilia) (submittedVersion, cc-by)
- University of Birmingham Research Portal (University of Birmingham) (submittedVersion)
- Bristol Research (University of Bristol) (submittedVersion)
- Funders
- Cancer Research UK
- Topics
- Social Sciences › Decision Sciences › Statistics, Probability and Uncertainty › Meta-analysis and systematic reviews
- Physical Sciences › Mathematics › Statistics and Probability › Statistical Methods in Epidemiology
- Health Sciences › Medicine › Public Health, Environmental and Occupational Health › Clinical practice guidelines implementation
- Keywords
- QUADAS-2, diagnostic accuracy studies, quality assessment, risk of bias, applicability, patient selection, index tests, reference materials, flowcharts, systematic reviews
- MeSH terms
- Diagnosis, Humans, Quality Control, Surveys and Questionnaires, Reference Standards, Review Literature as Topic, Time Factors, Bias, Patient Selection, Evidence-Based Medicine
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
A language model drew the claims from the paper on 2026-11-23, under version 3 of the claim definition (model deepseek-v4.1-flash, prompt extract-v3).
A second model labelled each claim on 2026-11-23 (model jev-1.13-20260917, definition revision gold-guideline-v0.2).
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.