QUADAS-2: A Revised Tool for the Quality Assessment of Diagnostic Accuracy Studies
Open accessThe DOI matches its Crossref record; 18 of the 18 references it cites were found in a registry or an index; none of the 21 sources its claims cite is checked for support yet.
Abstract
In 2003, the QUADAS tool for systematic reviews of diagnostic accuracy studies was developed. Experience, anecdotal reports, and feedback suggested areas for improvement; therefore, QUADAS-2 was developed. This tool comprises 4 domains: patient selection, index test, reference standard, and flow and timing. Each domain is assessed in terms of risk of bias, and the first 3 domains are also assessed in terms of concerns regarding applicability. Signalling questions are included to help judge risk of bias. The QUADAS-2 tool is applied in 4 phases: summarize the review question, tailor the tool and produce review-specific guidance, construct a flow diagram for the primary study, and judge bias and applicability. This tool will allow for more transparent rating of bias and applicability of primary diagnostic accuracy studies.
Overview
CoChat Summary
TL;DR
QUADAS-2 is a revised tool for assessing risk of bias and applicability in diagnostic accuracy studies, developed through a 4-stage evidence-based consensus process. It replaces the original QUADAS “yes/no/unclear” quality rating with domain-level judgments of low, high, or unclear risk of bias and concerns about applicability.
Key findings
- QUADAS-2 separates “quality” into risk of bias and concerns regarding applicability, defining quality as the degree to which diagnostic accuracy estimates avoided bias and the extent to which primary studies are applicable to the review question.
- The tool has 4 key domains—patient selection, index test, reference standard, and flow and timing—with the first 3 also assessed for applicability; it is completed in 4 phases and uses signaling questions to help judge risk of bias.
- Development drew on 4 reviews: 54 diagnostic accuracy reviews published between 2007 and 2009, structured feedback from 64 systematic reviewers who had used QUADAS, 101 studies on sources of bias and variation, and 8 studies evaluating QUADAS; a 1-day consensus meeting had 24 attendees, and piloting occurred in 5 reviews.
- Interrater reliability varied considerably, with better agreement on applicability than on risk of bias; all participants preferred QUADAS-2 to the original tool, but the authors could not currently include criteria for studies comparing multiple index tests because the evidence base was insufficient.
Methods
- Tool development followed Moher and colleagues’ 4-stage approach: define the scope, review the evidence base, hold a face-to-face consensus meeting, and refine through piloting.
- A steering group of 9 experts set the scope; the consensus meeting was held on 21 September 2010 in Birmingham, United Kingdom, with 24 attendees who split into groups of 4 to 6 participants; multiple rounds of piloting used online questionnaires and other feedback, including pairs of reviewers piloting QUADAS-2 in 5 reviews.
- No primary statistical analysis was reported; the work synthesized evidence reviews, consensus decisions, and pilot feedback to produce and refine the tool.
Limitations
- Stated: the authors decided they cannot currently include criteria for assessing studies that compare multiple index tests within QUADAS-2 because of the limited evidence base on risk of bias and sources of variation in such studies, and they plan future work on this topic.
- Stated: piloting showed poor interrater reliability and problems applying the domain on comparative accuracy studies; interrater reliability varied considerably overall, with better agreement on applicability than on risk of bias.
- Evident from the text: full details of the 4 evidence reviews were to be published separately, and the main text reports no quantitative reliability estimates, referring instead to an Appendix Table.
Model-written summary. Check it against the paper before relying on it.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
0 Valid · 0 Not valid · 16 Not checked · 24 Own results and interpretations
In the paper
“In a review on anti-cyclic citrullinated peptide antibodies for diagnosing rheumatoid arthritis (10), we found that some studies enrolled consecutive participants with confirmed diagnoses. In these studies, testing for anticyclic citrullinated peptide antibody showed greater sensitivity than in studies that included patients with suspected disease but an unconfirmed diagnosis (that is, difficult-t”
§ QUADAS-2: A Revised Tool for the Quality Assessment of Diagnostic Accuracy Studies > Signaling question 2: Was a case-control design avoided? Signaling question 3: Did the study avoid inappropriate exclusions?
What the sources say
- Not matchedcites [10]
The reference list we hold has no entry [10].
plainstates an association- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Not matched
A statement the paper makes itself — it cites no source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“Studies that make inappropriate exclusions (for example, not including”
§ QUADAS-2: A Revised Tool for the Quality Assessment of Diagnostic Accuracy Studies > Signaling question 2: Was a case-control design avoided? Signaling question 3: Did the study avoid inappropriate exclusions?
hedgedstates a possible cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
None of the sources cited for this claim could be matched to a paper, so there is nothing to check it against.
In the paper
“Because the accuracy of a test may depend on where it will be used in the diagnostic pathway, review authors are asked to describe patients in terms of setting, intended use of the index test, patient presentation, and previous testing (8,9).”
§ QUADAS-2: A Revised Tool for the Quality Assessment of Diagnostic Accuracy Studies > Phase 1: Review Question
What the sources say
- Not matchedcites [8]
The reference list we hold has no entry [8].
- Not matchedcites [9]
The reference list we hold has no entry [9].
hedgedstates a possible cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Not matched
In the paper
“Development of QUADAS-2 was based on the 4-stage approach proposed by Moher and colleagues (4): define the scope, review the evidence base, hold a face-to-face consensus meeting, and refine the tool through piloting.”
§ QUADAS-2: A Revised Tool for the Quality Assessment of Diagnostic Accuracy Studies > METHODS
What the sources say
- Not matchedcites [4]
The reference list we hold has no entry [4].
plainstates a cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: unclear — It is unclear whether the paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Not matched
None of the sources cited for this claim could be matched to a paper, so there is nothing to check it against.
In the paper
“Studies enrolling participants with known disease and a control group without the condition may similarly exaggerate diagnostic accuracy (7,11).”
§ QUADAS-2: A Revised Tool for the Quality Assessment of Diagnostic Accuracy Studies > Signaling question 2: Was a case-control design avoided? Signaling question 3: Did the study avoid inappropriate exclusions?
What the sources say
- Not matchedcites [7]
The reference list we hold has no entry [7].
- Not matchedcites [11]
The reference list we hold has no entry [11].
hedgedstates a possible cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Not matched
10 more claims
Create a free account to see all 40 claims and every source verdict.
- Probably not a substantial claim. 19
- It may state two separate claims as one. 16
- The quote only partly states this claim. 2
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“We assessed the study-level risk of bias with the QUADAS-2 tool”
In the citing paper
“We developed a revised risk-of-bias assessment tool to address these issues, incorporate advances in assessment of risk of bias used in other recently developed tools, 9 10 and integrate recent developments in estimation of intervention effects from randomised trials. 11”
From RoB 2: a revised tool for assessing risk of bias in randomised trials (2019) · cites this paper as [10]
In the citing paper
“Two reviewers independently assessed the quality of the included studies with the Quality Assessment of Diagnostic Accuracy Studies (Quadas-2) [33].”
From High-standard predictive equations for estimating body composition using bioelectrical impedance analysis: a systematic review (2024) · cites this paper as [33]
In the citing paper
“The quality of the selected studies was rigorously assessed using the Checklist for Artificial Intelligence in Medical Imaging (CLAIM) alongside the Quality Assessment of Diagnostic Accuracy Studies-2 (QUADAS-2).23,24”
From Artificial Intelligence Detection and Segmentation Models: A Systematic Review and Meta-Analysis of Brain Tumors in Magnetic Resonance Imaging (2024) · cites this paper as [24]
In the citing paper
“The methodological quality of each selected study was assessed according to the Quality Assessment of Diagnostic Accuracy Studies (QUADAS-2) checklist [15]”
From The diagnostic accuracy of digital, infrared and mercury-in-glass thermometers in measuring body temperature: a systematic review and network meta-analysis (2021) · cites this paper as [15]
20 more claims about this paper
Create a free account to see every claim other papers make about this one.
Citations
Cites
The Cochrane Collaboration's tool for assessing risk of bias in randomised trials
Higgins, J. P. T., Altman, D. G., Gotzsche, P. C., Juni, P., Moher, D., Oxman, A. D., Savovic, J., Schulz, K. F., Weeks, L., Sterne, J. A. C., et al. (2011) · BMJ · doi:10.1136/bmj.d5928 · Cited by 33,817
Self-citationWhiting, P., Rutjes, A. W., Reitsma, J. B., Bossuyt, P. M., & Kleijnen, J. (2003) · BMC Medical Research Methodology · doi:10.1186/1471-2288-3-25 · Cited by 3,592
Self-citationThe Hazards of Scoring the Quality of Clinical Trials for Meta-analysis
Jüni, P. (1999) · JAMA · doi:10.1001/jama.282.11.1054 · Cited by 1,981
Empirical evidence of design-related bias in studies of diagnostic tests.
Lijmer, J. G. (1999) · JAMA · doi:10.1001/jama.282.11.1061 · Cited by 1,861 · cited 2×
“Studies enrolling participants with known disease and a control group without the condition may similarly exaggerate diagnostic accuracy (7, 11).”
BackgroundGuidance for Developers of Health Research Reporting Guidelines
Moher, D., Schulz, K. F., Simera, I., & Altman, D. G. (2010) · PLoS Medicine · doi:10.1371/journal.pmed.1000217 · Cited by 1,437
Systematic Reviews of Diagnostic Test Accuracy
Leeflang, M. M. G., Deeks, J. J., Gatsonis, C., & Bossuyt, P. M. M. (2008) · Annals of Internal Medicine · doi:10.7326/0003-4819-149-12-200812160-00008 · Cited by 1,124
Self-citationSources of Variation and Bias in Studies of Diagnostic Accuracy: A Systematic Review
Whiting, P., Rutjes, A. W. S., Reitsma, J. B., Glas, A. S., Bossuyt, P. M. M., & Kleijnen, J. (2004) · Annals of Internal Medicine · doi:10.7326/0003-4819-140-3-200402030-00010 · Cited by 798 · cited 4×
“The third review was an update on sources of bias and variation in diagnostic accuracy studies that included 101 studies (7).”
BackgroundInfluentialSelf-citationEvaluation of QUADAS, a tool for the quality assessment of diagnostic accuracy studies
Whiting, P. F., Weswood, M. E., Rutjes, A. W., Reitsma, J. B., Bossuyt, P. N., & Kleijnen, J. (2006) · BMC Medical Research Methodology · doi:10.1186/1471-2288-6-9 · Cited by 769
Self-citationLeeflang, M. M. G., Moons, K. G. M., Reitsma, J. B., & Zwinderman, A. H. (2008) · Clinical Chemistry · doi:10.1373/clinchem.2007.096032 · Cited by 346 · cited 1×
“Test performance is likely to be poorer in an independent sample of patients in whom the same threshold is used (12).”
BackgroundSelf-citationNo role for quality scores in systematic reviews of diagnostic accuracy studies
Whiting, P., Harbord, R., & Kleijnen, J. (2005) · BMC Medical Research Methodology · doi:10.1186/1471-2288-5-19 · Cited by 337
Self-citation
Cited by
Items 2,801–2,900 of 14,770
Diagnostic Value of Concentration of Circulating Cell-Free DNA in Breast Cancer: A Meta-Analysis
Yu, D., Tong, Y., Guo, X., Feng, L., Jiang, Z., Ying, S., Jia, J., Fang, Y., Yu, M., Xia, H., et al. (2019) · Frontiers in Oncology · doi:10.3389/fonc.2019.00095 · Cited by 56
Ota, K., Fukui, K., Oba, K., Shimoda, A., Ota, K., Ota, K., Sakaue, M., & Takasu, A. (2019) · Journal of Medical Ultrasonics · doi:10.1007/s10396-019-00937-3 · Cited by 49
McAleenan, A., Kelly, C., Spiga, F., Kernohan, A., Cheng, H., Dawson, S., Schmidt, L., Robinson, T., Brandner, S., Faulkner, C., et al. (2021) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd013316.pub2 · Cited by 57
Liu, T., Xu, C., Wang, M., Niu, Z., & Qi, D. Y. (2019) · BMC Anesthesiology · doi:10.1186/s12871-019-0744-4 · Cited by 49
Accuracy of the short‐form Montreal Cognitive Assessment: Systematic review and validation
McDicken, J. A., Elliott, E., Blayney, G., Makin, S., Ali, M., Larner, A. J., Quinn, T. J., & Collaborators, O. B. O. T. V. (2019) · International Journal of Geriatric Psychiatry · doi:10.1002/gps.5162 · Cited by 50
Raffone, A., Travaglino, A., Saccone, G., Cieri, M., Mascolo, M., Mollo, A., Insabato, L., & Zullo, F. (2019) · Apmis · doi:10.1111/apm.12977 · Cited by 52
Mesa, L. E., Manrique, R., Muskus, C., & Robledo, S. M. (2020) · PLoS neglected tropical diseases · doi:10.1371/journal.pntd.0007981 · Cited by 49
Liang, Y., & Li, D. (2020) · BMC Gastroenterology · doi:10.1186/s12876-020-01234-x · Cited by 49
Singh, R., Wilson, M. P., Katlariwala, P., Murad, M. H., McInnes, M. D. F., & Low, G. (2020) · European Journal of Gastroenterology & Hepatology · doi:10.1097/meg.0000000000001724 · Cited by 51
Conway, A., Bittner, M., Phan, D., Chang, K., Kamboj, N., Tipton, E., & Parotto, M. (2020) · Journal of Clinical Monitoring and Computing · doi:10.1007/s10877-020-00543-6 · Cited by 51
Lung Ultrasound for the Diagnosis of Neonatal Respiratory Distress Syndrome: A Meta-analysis
Wu, J., Wang, Y., Zhao, A., & Wang, Z. (2020) · Ultrasound Quarterly · doi:10.1097/ruq.0000000000000490 · Cited by 60
Timmerhuis, H. C., van Dijk, S. M., Verdonk, R. C., Bollen, T. L., Bruno, M. J., Fockens, P., van Hooft, J. E., Voermans, R. P., Besselink, M. G., van Santvoort, H. C., et al. (2020) · Digestive Diseases and Sciences · doi:10.1007/s10620-020-06413-0 · Cited by 54
Mai, H., Kim, J., Choi, Y., & Lee, D. (2020) · International Journal of Environmental Research and Public Health · doi:10.3390/ijerph18010094 · Cited by 49
Blood-Based Biomarkers for Glioma in the Context of Gliomagenesis: A Systematic Review
Ali, H., Harting, R., de Vries, R., Ali, M., Würdinger, T., & Best, M. G. (2021) · Frontiers in Oncology · doi:10.3389/fonc.2021.665235 · Cited by 54
Kang, J. W., Eun, Y., & Lee, Y. C. (2021) · International Journal of Molecular Sciences · doi:10.3390/ijms22137026 · Cited by 49
Li, L., Zhang, J., Zhe, X., Tang, M., Zhang, X., Lei, X., & Zhang, L. (2022) · European Journal of Radiology · doi:10.1016/j.ejrad.2022.110243 · Cited by 54
Goyal, H., Sherazi, S. A. A., Gupta, S., Perisetti, A., Achebe, I., Ali, A. B., Tharian, B., Thosani, N. C., & Sharma, N. R. (2022) · Therapeutic Advances in Gastroenterology · doi:10.1177/17562848221093873 · Cited by 49
O’Sullivan, J. W., Banerjee, A., Heneghan, C. J., & Plüddemann, A. (2018) · BMJ Evidence-Based Medicine · doi:10.1136/bmjebm-2018-110919 · Cited by 49
Hayden, M. K., Hanson, K. E., Englund, J. A., Lee, F., Lee, M. J., Loeb, M. B., Morgan, D. J., Patel, R., Alayli, A. E., Mikati, I. K. E., et al. (2023) · Clinical Infectious Diseases · doi:10.1093/cid/ciad032 · Cited by 52
Suspected cancer (part 2--adults): reference tables from updated NICE guidance
Hamilton, W. T., Hajioff, S., Graham, J., & Schmidt‐Hansen, M. (2015) · BMJ · doi:10.1136/bmj.h3044 · Cited by 49
Lopes, T. J. A., Ferrari, D., Ioannidis, J., Simic, M., Mícolis de Azevedo, F., & Pappas, E. (2018) · Journal of Orthopaedic & Sports Physical Therapy · doi:10.2519/jospt.2018.8006 · Cited by 48
Accuracy of FGF‐21 and GDF‐15 for the diagnosis of mitochondrial disorders: A meta‐analysis
Lin, Y., Ji, K., Ma, X., Liu, S., Li, W., Zhao, Y., & Yan, C. (2020) · Annals of Clinical and Translational Neurology · doi:10.1002/acn3.51104 · Cited by 53
Diagnostic accuracy of point-of-care ultrasound for pulmonary tuberculosis: A systematic review
Bigio, J., Kohli, M., Klinton, J. S., MacLean, E. L.-H., Gore, G. C., Small, P. M., Rühwald, M., Weber, S. F., Jha, S. K., & Pai, M. (2021) · PLoS ONE · doi:10.1371/journal.pone.0251236 · Cited by 48
Park, H. Y., Kim, M., Suh, C. H., Kim, S. Y., Shim, W. H., & Kim, S. J. (2021) · European Radiology · doi:10.1007/s00330-021-08031-4 · Cited by 52
Red reflex test screening for neonates: A systematic review and meta analysis
Taksande, A. M., Jameel, P. Z., Taksande, B., & Meshram, R. (2021) · Indian Journal of Ophthalmology · doi:10.4103/ijo.ijo_3632_20 · Cited by 55
Giurgiu, M., Timm, I., Becker, M. L., Schmidt, S., Wunsch, K., Nissen, R., Davidovski, D., Bussmann, J. B. J., Nigg, C. R., Reichert, M., et al. (2022) · JMIR mhealth and uhealth · doi:10.2196/36377 · Cited by 55
Silvagni, E., Callegher, S. Z., Mauric, E., Chiricolo, S., Schreiber, N., Tullio, A., Zabotti, A., Scirè, C. A., Dejaco, C., & Sakellariou, G. (2022) · Rheumatology · doi:10.1093/rheumatology/keac261 · Cited by 48
Jia, L.-L., Zhao, J.-X., pan, N., Shi, L., Zhao, L., Tian, J., & Huang, G. (2022) · European Journal of Radiology Open · doi:10.1016/j.ejro.2022.100438 · Cited by 51
“In this systematic review, we aimed to determine the diagnostic accuracy of chest imaging-based AI models in distinguishing COVID-19 from other pneumonias, using the QUADAS-2, RQS tool, and the CLAIM checklist assess the quality of included studies.”
InfluentialArtificial intelligence and machine learning in cardiotocography: A scoping review
Aeberhard, J. L., Radan, A., Delgado-Gonzalo, R., Strahm, K. M., Sigurthorsdottir, H., Schneider, S., & Surbek, D. (2022) · European Journal of Obstetrics & Gynecology and Reproductive Biology · doi:10.1016/j.ejogrb.2022.12.008 · Cited by 47
Yamazaki, H., Yamashita, Y., Shimokawa, T., Minaga, K., Ogura, T., & Kitano, M. (2023) · DEN Open · doi:10.1002/deo2.274 · Cited by 48
Schopf, C. M., Ramwala, O. A., Lowry, K. P., Hofvind, S. S. H., Marinovich, M. L., Houssami, N., Elmore, J. G., Dontchos, B. N., Lee, J. M., & Lee, C. I. (2023) · Journal of the American College of Radiology · doi:10.1016/j.jacr.2023.10.018 · Cited by 59
Huang, H., Hsiao, Y., Karmakar, R., Mukundan, A., Chaudhary, P., Hsieh, S.-C., & Wang, H. (2023) · Cancers · doi:10.3390/cancers15235634 · Cited by 48
Rokhshad, R., Mohammad‐Rahimi, H., Price, J. B., Shoorgashti, R., Abbasiparashkouh, Z., Esmaeili, M., Sarfaraz, B., Rokhshad, A., Motamedian, S. R., Soltani, P., et al. (2024) · Clinical Oral Investigations · doi:10.1007/s00784-023-05475-4 · Cited by 55
“Three reviewers (Z.A., R.S., and M.E.) evaluated a study’s risk of bias independently and in triplicate using the Quality Assessment of Diagnostic Accuracy Studies-2 (QUADAS-2) tool [36].”
Artificial intelligence for MRI stroke detection: a systematic review and meta-analysis
Bojsen, J. A., Elhakim, M. T., Graumann, O., Gaist, D., Nielsen, M., Harbo, F. S. G., Krag, C. H., Sagar, M. V., Kruuse, C. R., Boesen, M., et al. (2024) · Insights into Imaging · doi:10.1186/s13244-024-01723-7 · Cited by 56
“For risk of bias analysis, a modi fi ed version of the quality assessment for diagnostic accuracy studies 2 (QUADAS-Table 2) tool was used [30].”
Large Language Models in Dental Licensing Examinations: Systematic Review and Meta-Analysis
Liu, M., Okuhara, T., Huang, W., Ogihara, A., Nagao, H. S., Okada, H., & Kiuchi, T. (2024) · International Dental Journal · doi:10.1016/j.identj.2024.10.014 · Cited by 62
“24 In this evaluation framework, ‘task generation’, ‘conversation structure’, and ‘evaluation’ align with ‘patient selection’, ‘index test’, and ‘reference standard’ in the QUA-DAS-2, 25 respectively.”
Wright, B., Barry, M., Hughes, E., Trépel, D., Ali, S., Allgar, V. L., Cottrill, L., Duffy, S., Fell, J., Glanville, J., et al. (2015) · Health Technology Assessment · doi:10.3310/hta19520 · Cited by 59
Ma, R. H., Ge, Z., & Li, G. (2015) · International Endodontic Journal · doi:10.1111/iej.12490 · Cited by 48
Saccone, G., Simonetti, B., & Berghella, V. (2015) · BJOG An International Journal of Obstetrics & Gynaecology · doi:10.1111/1471-0528.13724 · Cited by 48
Khuroo, M. S., Khuroo, N. S., & Khuroo, M. S. (2014) · Journal of Clinical and Experimental Hepatology · doi:10.1016/j.jceh.2014.07.008 · Cited by 48
Transbronchial Needle Aspiration: A Systematic Review on Predictors of a Successful Aspirate
Bonifazi, M., Zuccatosta, L., Trisolini, R., Moja, L., & Gasparini, S. (2013) · Respiration · doi:10.1159/000350466 · Cited by 48
Riemsma, R., Al, M., Corro Ramos, I., Deshpande, S., Armstrong, N., Lee, Y.-C., Ryder, S., Noake, C., Krol, M., Oppe, M., et al. (2013) · Health Technology Assessment · doi:10.3310/hta17610 · Cited by 47
Ferreira, D., Rivero-Santana, A., Perestelo-Pérez, L., Westman, E., Wahlund, L.-O., SarrÃa, A., & Serrano-Aguilar, P. (2014) · Frontiers in Aging Neuroscience · doi:10.3389/fnagi.2014.00287 · Cited by 45
Liu, B.-J., Li, D., Xu, H., Guo, L., Zhang, Y.-F., Xu, J.-M., Liu, C., Liu, L.-N., Li, X., Xu, X.-H., et al. (2015) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2015.08.003 · Cited by 48
Health assessment of commercial drivers: a meta-narrative systematic review
Abu Dabrh, A. M., Firwana, B., Cowl, C. T., Steinkraus, L. W., Prokop, L. J., & Murad, M. H. (2014) · BMJ Open · doi:10.1136/bmjopen-2013-003434 · Cited by 44
Swain, M. S., Henschke, N., Kamper, S. J., Downie, A., Koes, B. W., & Maher, C. G. (2014) · Chiropractic & Manual Therapies · doi:10.1186/s12998-014-0025-8 · Cited by 49
Young, I., Waddell, L. A., Sánchez, J., Wilhelm, B., McEwen, S. A., & Rajić, A. (2013) · Preventive Veterinary Medicine · doi:10.1016/j.prevetmed.2013.11.009 · Cited by 53
Ultrasound Elastography Is Useful for Evaluation of Liver Fibrosis in Children—A Systematic Review
Andersen, S. B., Ewertsen, C., Carlsen, J. F., Henriksen, B. M., & Nielsen, M. B. (2016) · Journal of Pediatric Gastroenterology and Nutrition · doi:10.1097/mpg.0000000000001171 · Cited by 49
Liu, J., Li, W., Deng, M., Liu, D., Ma, Q., & Feng, X. (2016) · PLoS ONE · doi:10.1371/journal.pone.0159636 · Cited by 48
Maas, E. T., Juch, J. N. S., Ostelo, R., Groeneweg, G., Kallewaard, J. W., Koes, B. W., Verhagen, A. P., Huygen, F. J. P. M., & van Tulder, M. W. (2016) · European Journal of Pain · doi:10.1002/ejp.963 · Cited by 54
Edwards, S. J., Osei-Assibey, G., Patalay, R., Wakefield, V., & Karner, C. (2017) · Clinical and Experimental Dermatology · doi:10.1111/ced.13055 · Cited by 48
Xiong, Y., Ma, S., Mo, Y., Huo, S.-T., Wen, Y.-Q., & Chen, Q. (2017) · Journal of Cancer Research and Clinical Oncology · doi:10.1007/s00432-017-2391-9 · Cited by 49
Ferreira, J. B., CHRISTOVAM, I. O., Alencar, D. S., da Motta, A. F. J., Mattos, C. T., & Cury-Saramago, A. D. A. (2017) · Dentomaxillofacial Radiology · doi:10.1259/dmfr.20160455 · Cited by 48
Gao, L., Wang, Y., Jiang, Y., Yang, X., Liu, R., Xi, X., Zhu, S., Zhao, R., Lai, X., Zhang, X., et al. (2017) · Medicine · doi:10.1097/md.0000000000006564 · Cited by 62
Yuan, J., Yan, Y., Zhang, J., Wang, B., & Feng, J. (2017) · International Orthopaedics · doi:10.1007/s00264-017-3647-3 · Cited by 51
Urinary Biomarkers in the Evaluation of Primary Hematuria: A Systematic Review and Meta-Analysis
Sathianathen, N. J., Butaney, M., Weight, C., Kumar, R. A., & Konety, B. R. (2018) · Bladder Cancer · doi:10.3233/blc-180179 · Cited by 48
Salameh, J., McInnes, M. D. F., McGrath, T. A., Salameh, G., & Schieda, N. (2019) · American Journal of Roentgenology · doi:10.2214/ajr.18.20527 · Cited by 50
Christie, D., & Sharpley, C. F. (2019) · Prostate Cancer · doi:10.1155/2019/6932572 · Cited by 48
Patel, M., Lee, S. I., Akyea, R. K., Grindlay, D. J. C., Francis, N. A., Levell, N. J., Smart, P., Kai, J., & Thomas, K. S. (2019) · British Journal of Dermatology · doi:10.1111/bjd.17857 · Cited by 48
Freeman, K., Willis, B. H., Fraser, H., Taylor‐Phillips, S., & Clarke, A. (2019) · BMJ Open · doi:10.1136/bmjopen-2018-027428 · Cited by 55
Vieito, N. P., Zarraquiños, S., & Cubiella, J. (2019) · World Journal of Gastroenterology · doi:10.3748/wjg.v25.i19.2383 · Cited by 51
Did This Patient Have Cardiac Syncope? The Rational Clinical Examination Systematic Review
Albassam, O. T., Redelmeier, R. J., Shadowitz, S., Husain, A. M., Simel, D. L., & Etchells, E. E. (2019) · JAMA · doi:10.1001/jama.2019.8001 · Cited by 55
Arellano‐Ruiz, P., García‐Hermoso, A., Cavero‐Redondo, I., Pozuelo‐Carrascosa, D. P., Martínez‐Vizcaíno, V., & Solera-Martínez, M. (2019) · European Journal of Pediatrics · doi:10.1007/s00431-019-03464-y · Cited by 53
Shafiq, M., Sethi, J. S., Ali, M. S., Ghori, U. K., Saghaie, T., & Folch, E. E. (2019) · CHEST Journal · doi:10.1016/j.chest.2019.09.023 · Cited by 48
Observational Gait Assessment Scales in Patients with Walking Disorders: Systematic Review
Ridao-Fernández, C., Pinto, E. P., & Chamorro-Moriana, G. (2019) · BioMed Research International · doi:10.1155/2019/2085039 · Cited by 50
Mo, Y., Dong, X., & Wang, X. (2019) · Journal of the American Medical Directors Association · doi:10.1016/j.jamda.2019.09.002 · Cited by 50
Chen, S., Chen, K., Wang, S., Zhu, H., Lü, L., Zhang, X., Tong, A., Pan, H., Wang, R., & Lu, Z. (2019) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/clinem/dgz194 · Cited by 53
Villegas-Tovar, E., Jiménez-Lillo, J., Jimenez-Valerio, V., Díaz-Girón-Gidi, A., Faes-Petersen, R., Piñeiro, A. O., de Lacy, F. B., Martinez-Portilla, R. J., & Lacy, A. M. (2019) · Surgical Endoscopy · doi:10.1007/s00464-019-07274-z · Cited by 51
Medeiros, T. M., Altmayer, S., Watte, G., Zanon, M., Dias, A. B., Concatto, N. H., Paes, J. H., Mattiello, R., Santos, F. D. S., Mohammed, T.-L. H., et al. (2020) · European Radiology · doi:10.1007/s00330-020-06703-1 · Cited by 49
Purich, K., Dang, J. T., Poonja, A., Sun, W. Y. L., Bigam, D. L., Birch, D. W., & Karmali, S. (2020) · Surgical Endoscopy · doi:10.1007/s00464-020-07543-2 · Cited by 48
Ortiz, M. I. G., Alencar, C. D. M., de Paula, B. L. F., Magno, M. B., Maia, L. C., & Silva, C. M. (2020) · Journal of Dentistry · doi:10.1016/j.jdent.2020.103351 · Cited by 57
Schieda, N., van der Pol, C. B., Walker, D., Tsampalieros, A. K., Maralani, P. J., Woo, S., & Davenport, M. S. (2020) · Radiology · doi:10.1148/radiol.2020200073 · Cited by 51
Zhai, Y., Cai, S., & Zhang, Y. (2020) · Journal of Pain and Symptom Management · doi:10.1016/j.jpainsymman.2020.06.006 · Cited by 52
Haj‐Mirzaian, A., Eng, J., Khorasani, R., Raja, A. S., Levin, A. S., Smith, S. E., Johnson, P. T., & Demehri, S. (2020) · Radiology · doi:10.1148/radiol.2020192167 · Cited by 55
Diagnosing acute aortic syndrome: a Canadian clinical practice guideline
Ohle, R., Yan, J. W., Yadav, K., Cournoyer, A., Savage, D. W., Jetty, P., Atoui, R., Bittira, B., Wilson, B., Gupta, A. K., et al. (2020) · Canadian Medical Association Journal · doi:10.1503/cmaj.200021 · Cited by 51
Bauckneht, M., Albano, D., Annunziata, S., Santo, G., Guglielmo, P., Frantellizzi, V., Branca, A., Ferrari, C., Vento, A., Mirabile, A., et al. (2020) · Diagnostics · doi:10.3390/diagnostics10080598 · Cited by 48
Dodich, A., Crespi, C., Santi, G. C., Cappa, S. F., & Cerami, C. (2020) · Neuropsychology Review · doi:10.1007/s11065-020-09457-1 · Cited by 51
Wuerdemann, N., Jain, R. A., Adams, A., Speel, E. M., Wagner, S., Joosse, S. A., & Klußmann, J. P. (2020) · Cancers · doi:10.3390/cancers12102997 · Cited by 50
Diagnostic Test Accuracy of the 4AT for Delirium Detection: A Systematic Review and Meta-Analysis
Jeong, E., Park, J., & Lee, J. (2020) · International Journal of Environmental Research and Public Health · doi:10.3390/ijerph17207515 · Cited by 51
Candidate RNA biomarkers in biofluids for early diagnosis of ovarian cancer: A systematic review
Hulstaert, E., Morlion, A., Levanon, K., Vandesompele, J., & Mestdagh, P. (2020) · Gynecologic Oncology · doi:10.1016/j.ygyno.2020.11.018 · Cited by 50
Kodama, S., Fujihara, K., Shiozaki, H., Horikawa, C., Yamada, M. H., Sato, T., Yaguchi, Y., Yamamoto, M., Kitazawa, M., Iwanaga, M., et al. (2021) · JMIR Diabetes · doi:10.2196/22458 · Cited by 49
Sherbaf, F. G., Sair, H. I., Shakoor, D., Fritz, J. M., Schwaiger, B. J., Johnson, M. H., & Demehri, S. (2021) · Radiology · doi:10.1148/radiol.2021203624 · Cited by 50
Deep learning for noninvasive liver fibrosis classification: A systematic review
Anteby, R., Klang, E., Horesh, N., Nachmany, I., Shimon, O., Barash, Y., Kopylov, U., & Soffer, S. (2021) · Liver International · doi:10.1111/liv.14966 · Cited by 50
Faiman, I., Smith, S. D. W., Hodsoll, J. P., Young, A. H., & Shotbolt, P. (2021) · Epilepsy & Behavior · doi:10.1016/j.yebeh.2021.108047 · Cited by 52
Zhou, Y., & O’Leary, T. J. (2021) · PLoS ONE · doi:10.1371/journal.pone.0254559 · Cited by 58
Ke, J., chen, Y., Wang, X., Wu, Z., & Chen, F. (2021) · BMJ Open · doi:10.1136/bmjopen-2020-048356 · Cited by 57
“19 20 The robustness of pooled results was also assessed by sensitivity analyses, which were also performed for studies using all three scoring systems and the endpoint MACE.”
Ezzatvar, Y., Izquierdo, M., Ramírez‐Vélez, R., Cruz, B. D. P., & García‐Hermoso, A. (2021) · Obesity Reviews · doi:10.1111/obr.13375 · Cited by 59
Gan, J., Nazarian, S., TEARE, J. P., Darzi, A. W., Ashrafian, H., & Thompson, A. J. (2022) · BMC Gastroenterology · doi:10.1186/s12876-021-02082-z · Cited by 53
Diagnostic Accuracy of Artificial Intelligence in Glaucoma Screening and Clinical Practice
Chaurasia, A. K., Greatbatch, C. J., & Hewitt, A. W. (2022) · Journal of Glaucoma · doi:10.1097/ijg.0000000000002015 · Cited by 54
Dhana, A., Hamada, Y., Kengne, A. P., Kerkhoff, A. D., Rangaka, M. X., Kredo, T., Baddeley, A., Miller, C., Gupta‐Wright, A., Fielding, K., et al. (2022) · The Lancet HIV · doi:10.1016/s2352-3018(22)00002-9 · Cited by 56
Buono, A. D., Faita, F., Peyrin‐Biroulet, L., Danese, S., & Allocca, M. (2022) · Journal of Crohn s and Colitis · doi:10.1093/ecco-jcc/jjac082 · Cited by 48
D, S. M. M., Goldin, E., Marchet, A., & Nitti, D. (2015) · International Journal of Cancer · doi:10.1002/ijc.29644 · Cited by 48
Diagnostic Value of Osteopontin in Ovarian Cancer: A Meta-Analysis and Systematic Review
Hu, Z.-D., Wei, T., Yang, M., Ma, N., Tang, Q., Qin, B., Fu, H., & Zhong, R. (2015) · PLoS ONE · doi:10.1371/journal.pone.0126444 · Cited by 53
Samim, M., Molenaar, I. Q., Seesing, M. F. J., van Rossum, P. S. N., van den Bosch, M. A. A. J., Ruers, T. J. M., Rinkes, I. H. M. B., van Hillegersberg, R., Lam, M. G. E. H., & Verkooijen, H. M. (2016) · Surgical Oncology · doi:10.1016/j.suronc.2016.12.006 · Cited by 48
McCarthy, J., Collins, D. L., & Ducharme, S. (2018) · NeuroImage: Clinical · doi:10.1016/j.nicl.2018.08.028 · Cited by 47
“The risk of bias and applicability of each included study was assessed with the QUADAS-2 tool (Whiting et al., 2011).”
Buijtendijk, M. F., Bet, B. B., Leeflang, M. M., Shah, H., Reuvekamp, T., Goring, T., Docter, D., Timmerman, M. G., Dawood, Y., Lugthart, M. A., et al. (2024) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd014715.pub2 · Cited by 47
Self-citationDickens, G. L., O’Shea, L. E., & Christensen, M. (2020) · International Journal of Nursing Studies · doi:10.1016/j.ijnurstu.2020.103526 · Cited by 63
Zhou, J., Yuan, X., Huang, H., Li, Y., Yu, H., Xu, C., & Luo, J. (2021) · Frontiers in Psychiatry · doi:10.3389/fpsyt.2021.644276 · Cited by 49
Desmond, T., Tran, V., Maharaj, M. M., Carnt, N. A., & White, A. J. R. (2021) · Graefe s Archive for Clinical and Experimental Ophthalmology · doi:10.1007/s00417-021-05271-4 · Cited by 49
Strauss, R., Menchetti, I., Perrier, L., Blondal, E., Peng, H. T., Sullivan‐Kwantes, W., Tien, H. C. N., Nathens, A. B., Beckett, A., Callum, J. L., et al. (2021) · Trauma Surgery & Acute Care Open · doi:10.1136/tsaco-2021-000773 · Cited by 48
Valizadeh, M., Ahmadi, A. R., Ebadinejad, A., Rahmani, F., & Abiri, B. (2022) · Reviews in Endocrine and Metabolic Disorders · doi:10.1007/s11154-022-09723-y · Cited by 50
Metadata
- Authors
- Whiting, P. F., Rutjes, A. W. S., Westwood, M. E., Mallett, S., Deeks, J. J., Reitsma, J. B., Leeflang, M. M. G., Sterne, J. A. C., Bossuyt, P. M. M., & the QUADAS-2 Group*
- Affiliations
- University of Bern (CH)
- Corresponding author
- Whiting, Penny F.
- ORCID
- Venue
- Annals of Internal Medicine
- Publisher
- American College of Physicians
- Published
- 2011-10-18
- Volume
- 155
- Issue
- 8
- Pages
- 529-536
- ISSN
- 0003-4819 (ISSN-L)
- 1539-3704
- OpenAlex
- W2107638293
- Semantic Scholar
- 8a5d0b5a9271ea14bcb8479bc32d3844a80655b9
- Cited by
- 14,199
- References
- 18
- Citations by year
- 2026: 1484 · 2025: 1569 · 2024: 1524 · 2023: 1305 · 2022: 1420 · 2021: 1514 · 2020: 1245 · 2019: 955 · 2018: 767 · 2017: 637 · 2016: 580 · 2015: 528 · 2014: 363 · 2013: 217 · 2012: 75
- FWCI
- 224.36
- Type
- journal article
- Language
- en
- Open access
- green
- hdl.handle.net
- Licence
- cc-by
- www.acpjournals.org/journal/aim/text-and-data-mining (tdm)
- Locations
- Annals of Internal Medicine (publishedVersion)
- PubMed (publishedVersion)
- Pure Amsterdam UMC (publishedVersion)
- Data Archiving and Networked Services (DANS) (submittedVersion)
- Florence Research (University of Florence) (submittedVersion)
- IRIS UNIMORE (University of Modena and Reggio Emilia) (submittedVersion, cc-by)
- University of Birmingham Research Portal (University of Birmingham) (submittedVersion)
- Bristol Research (University of Bristol) (submittedVersion)
- Funders
- Cancer Research UK
- Topics
- Social Sciences › Decision Sciences › Statistics, Probability and Uncertainty › Meta-analysis and systematic reviews
- Physical Sciences › Mathematics › Statistics and Probability › Statistical Methods in Epidemiology
- Health Sciences › Medicine › Public Health, Environmental and Occupational Health › Clinical practice guidelines implementation
- Keywords
- QUADAS-2, diagnostic accuracy studies, quality assessment, risk of bias, applicability, patient selection, index tests, reference materials, flowcharts, systematic reviews
- MeSH terms
- Diagnosis, Humans, Quality Control, Surveys and Questionnaires, Reference Standards, Review Literature as Topic, Time Factors, Bias, Patient Selection, Evidence-Based Medicine
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
A language model drew the claims from the paper on 2026-11-23, under version 3 of the claim definition (model deepseek-v4.1-flash, prompt extract-v3).
A second model labelled each claim on 2026-11-23 (model jev-1.13-20260917, definition revision gold-guideline-v0.2).
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.