In 2003, the QUADAS tool for systematic reviews of diagnostic accuracy studies was developed. Experience, anecdotal reports, and feedback suggested areas for improvement; therefore, QUADAS-2 was developed. This tool comprises 4 domains: patient selection, index test, reference standard, and flow and timing. Each domain is assessed in terms of risk of bias, and the first 3 domains are also assessed in terms of concerns regarding applicability. Signalling questions are included to help judge risk of bias. The QUADAS-2 tool is applied in 4 phases: summarize the review question, tailor the tool and produce review-specific guidance, construct a flow diagram for the primary study, and judge bias and applicability. This tool will allow for more transparent rating of bias and applicability of primary diagnostic accuracy studies.
Overview
CoChat Summary
TL;DR
QUADAS-2 is a revised tool for assessing risk of bias and applicability in diagnostic accuracy studies, developed through a 4-stage evidence-based consensus process. It replaces the original QUADAS “yes/no/unclear” quality rating with domain-level judgments of low, high, or unclear risk of bias and concerns about applicability.
Key findings
- QUADAS-2 separates “quality” into risk of bias and concerns regarding applicability, defining quality as the degree to which diagnostic accuracy estimates avoided bias and the extent to which primary studies are applicable to the review question.
- The tool has 4 key domains—patient selection, index test, reference standard, and flow and timing—with the first 3 also assessed for applicability; it is completed in 4 phases and uses signaling questions to help judge risk of bias.
- Development drew on 4 reviews: 54 diagnostic accuracy reviews published between 2007 and 2009, structured feedback from 64 systematic reviewers who had used QUADAS, 101 studies on sources of bias and variation, and 8 studies evaluating QUADAS; a 1-day consensus meeting had 24 attendees, and piloting occurred in 5 reviews.
- Interrater reliability varied considerably, with better agreement on applicability than on risk of bias; all participants preferred QUADAS-2 to the original tool, but the authors could not currently include criteria for studies comparing multiple index tests because the evidence base was insufficient.
Methods
- Tool development followed Moher and colleagues’ 4-stage approach: define the scope, review the evidence base, hold a face-to-face consensus meeting, and refine through piloting.
- A steering group of 9 experts set the scope; the consensus meeting was held on 21 September 2010 in Birmingham, United Kingdom, with 24 attendees who split into groups of 4 to 6 participants; multiple rounds of piloting used online questionnaires and other feedback, including pairs of reviewers piloting QUADAS-2 in 5 reviews.
- No primary statistical analysis was reported; the work synthesized evidence reviews, consensus decisions, and pilot feedback to produce and refine the tool.
Limitations
- Stated: the authors decided they cannot currently include criteria for assessing studies that compare multiple index tests within QUADAS-2 because of the limited evidence base on risk of bias and sources of variation in such studies, and they plan future work on this topic.
- Stated: piloting showed poor interrater reliability and problems applying the domain on comparative accuracy studies; interrater reliability varied considerably overall, with better agreement on applicability than on risk of bias.
- Evident from the text: full details of the 4 evidence reviews were to be published separately, and the main text reports no quantitative reliability estimates, referring instead to an Appendix Table.
Model-written summary. Check it against the paper before relying on it.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
0 Valid · 0 Not valid · 16 Not checked · 24 Own results and interpretations
In the paper
“In a review on anti-cyclic citrullinated peptide antibodies for diagnosing rheumatoid arthritis (10), we found that some studies enrolled consecutive participants with confirmed diagnoses. In these studies, testing for anticyclic citrullinated peptide antibody showed greater sensitivity than in studies that included patients with suspected disease but an unconfirmed diagnosis (that is, difficult-t”
§ QUADAS-2: A Revised Tool for the Quality Assessment of Diagnostic Accuracy Studies > Signaling question 2: Was a case-control design avoided? Signaling question 3: Did the study avoid inappropriate exclusions?
What the sources say
- Not matchedcites [10]
The reference list we hold has no entry [10].
plainstates an association- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Not matched
A statement the paper makes itself — it cites no source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“Studies that make inappropriate exclusions (for example, not including”
§ QUADAS-2: A Revised Tool for the Quality Assessment of Diagnostic Accuracy Studies > Signaling question 2: Was a case-control design avoided? Signaling question 3: Did the study avoid inappropriate exclusions?
hedgedstates a possible cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
None of the sources cited for this claim could be matched to a paper, so there is nothing to check it against.
In the paper
“Because the accuracy of a test may depend on where it will be used in the diagnostic pathway, review authors are asked to describe patients in terms of setting, intended use of the index test, patient presentation, and previous testing (8,9).”
§ QUADAS-2: A Revised Tool for the Quality Assessment of Diagnostic Accuracy Studies > Phase 1: Review Question
What the sources say
- Not matchedcites [8]
The reference list we hold has no entry [8].
- Not matchedcites [9]
The reference list we hold has no entry [9].
hedgedstates a possible cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Not matched
In the paper
“Development of QUADAS-2 was based on the 4-stage approach proposed by Moher and colleagues (4): define the scope, review the evidence base, hold a face-to-face consensus meeting, and refine the tool through piloting.”
§ QUADAS-2: A Revised Tool for the Quality Assessment of Diagnostic Accuracy Studies > METHODS
What the sources say
- Not matchedcites [4]
The reference list we hold has no entry [4].
plainstates a cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: unclear — It is unclear whether the paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Not matched
None of the sources cited for this claim could be matched to a paper, so there is nothing to check it against.
In the paper
“Studies enrolling participants with known disease and a control group without the condition may similarly exaggerate diagnostic accuracy (7,11).”
§ QUADAS-2: A Revised Tool for the Quality Assessment of Diagnostic Accuracy Studies > Signaling question 2: Was a case-control design avoided? Signaling question 3: Did the study avoid inappropriate exclusions?
What the sources say
- Not matchedcites [7]
The reference list we hold has no entry [7].
- Not matchedcites [11]
The reference list we hold has no entry [11].
hedgedstates a possible cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Not matched
10 more claims
Create a free account to see all 40 claims and every source verdict.
- Probably not a substantial claim. 19
- It may state two separate claims as one. 16
- The quote only partly states this claim. 2
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“We assessed the study-level risk of bias with the QUADAS-2 tool”
In the citing paper
“We developed a revised risk-of-bias assessment tool to address these issues, incorporate advances in assessment of risk of bias used in other recently developed tools, 9 10 and integrate recent developments in estimation of intervention effects from randomised trials. 11”
From RoB 2: a revised tool for assessing risk of bias in randomised trials (2019) · cites this paper as [10]
In the citing paper
“Two reviewers independently assessed the quality of the included studies with the Quality Assessment of Diagnostic Accuracy Studies (Quadas-2) [33].”
From High-standard predictive equations for estimating body composition using bioelectrical impedance analysis: a systematic review (2024) · cites this paper as [33]
In the citing paper
“The quality of the selected studies was rigorously assessed using the Checklist for Artificial Intelligence in Medical Imaging (CLAIM) alongside the Quality Assessment of Diagnostic Accuracy Studies-2 (QUADAS-2).23,24”
From Artificial Intelligence Detection and Segmentation Models: A Systematic Review and Meta-Analysis of Brain Tumors in Magnetic Resonance Imaging (2024) · cites this paper as [24]
In the citing paper
“The methodological quality of each selected study was assessed according to the Quality Assessment of Diagnostic Accuracy Studies (QUADAS-2) checklist [15]”
From The diagnostic accuracy of digital, infrared and mercury-in-glass thermometers in measuring body temperature: a systematic review and network meta-analysis (2021) · cites this paper as [15]
20 more claims about this paper
Create a free account to see every claim other papers make about this one.
Citations
Cites
The Cochrane Collaboration's tool for assessing risk of bias in randomised trials
Higgins, J. P. T., Altman, D. G., Gotzsche, P. C., Juni, P., Moher, D., Oxman, A. D., Savovic, J., Schulz, K. F., Weeks, L., Sterne, J. A. C., et al. (2011) · BMJ · doi:10.1136/bmj.d5928 · Cited by 33,817
Self-citationWhiting, P., Rutjes, A. W., Reitsma, J. B., Bossuyt, P. M., & Kleijnen, J. (2003) · BMC Medical Research Methodology · doi:10.1186/1471-2288-3-25 · Cited by 3,592
Self-citationThe Hazards of Scoring the Quality of Clinical Trials for Meta-analysis
Jüni, P. (1999) · JAMA · doi:10.1001/jama.282.11.1054 · Cited by 1,981
Empirical evidence of design-related bias in studies of diagnostic tests.
Lijmer, J. G. (1999) · JAMA · doi:10.1001/jama.282.11.1061 · Cited by 1,861 · cited 2×
“Studies enrolling participants with known disease and a control group without the condition may similarly exaggerate diagnostic accuracy (7, 11).”
BackgroundGuidance for Developers of Health Research Reporting Guidelines
Moher, D., Schulz, K. F., Simera, I., & Altman, D. G. (2010) · PLoS Medicine · doi:10.1371/journal.pmed.1000217 · Cited by 1,437
Systematic Reviews of Diagnostic Test Accuracy
Leeflang, M. M. G., Deeks, J. J., Gatsonis, C., & Bossuyt, P. M. M. (2008) · Annals of Internal Medicine · doi:10.7326/0003-4819-149-12-200812160-00008 · Cited by 1,124
Self-citationSources of Variation and Bias in Studies of Diagnostic Accuracy: A Systematic Review
Whiting, P., Rutjes, A. W. S., Reitsma, J. B., Glas, A. S., Bossuyt, P. M. M., & Kleijnen, J. (2004) · Annals of Internal Medicine · doi:10.7326/0003-4819-140-3-200402030-00010 · Cited by 798 · cited 4×
“The third review was an update on sources of bias and variation in diagnostic accuracy studies that included 101 studies (7).”
BackgroundInfluentialSelf-citationEvaluation of QUADAS, a tool for the quality assessment of diagnostic accuracy studies
Whiting, P. F., Weswood, M. E., Rutjes, A. W., Reitsma, J. B., Bossuyt, P. N., & Kleijnen, J. (2006) · BMC Medical Research Methodology · doi:10.1186/1471-2288-6-9 · Cited by 769
Self-citationLeeflang, M. M. G., Moons, K. G. M., Reitsma, J. B., & Zwinderman, A. H. (2008) · Clinical Chemistry · doi:10.1373/clinchem.2007.096032 · Cited by 346 · cited 1×
“Test performance is likely to be poorer in an independent sample of patients in whom the same threshold is used (12).”
BackgroundSelf-citationNo role for quality scores in systematic reviews of diagnostic accuracy studies
Whiting, P., Harbord, R., & Kleijnen, J. (2005) · BMC Medical Research Methodology · doi:10.1186/1471-2288-5-19 · Cited by 337
Self-citation
Cited by
Items 3,101–3,200 of 14,770
Martínez, G., Vernooij, R. W. M., Padilla, P. F., Zamora, J., Flicker, L. A., & Bonfill, X. (2017) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd012883 · Cited by 56
Wang, L., Wei, C., Deng, L., Wang, Z., Song, M., Xiong, Y., & Liu, M. (2018) · Journal of Stroke and Cerebrovascular Diseases · doi:10.1016/j.jstrokecerebrovasdis.2018.01.023 · Cited by 48
Singh, P., Arora, A., Strand, T. A., Leffler, D. A., Mäki, M., Kelly, C. P., Ahuja, V., & Makharia, G. K. (2018) · Journal of Clinical Gastroenterology · doi:10.1097/mcg.0000000000001081 · Cited by 49
Quantitative fecal immunochemical tests for colorectal cancer screening
Gies, A., Bhardwaj, M., Stock, C., Schrotz‐King, P., & Brenner, H. (2018) · International Journal of Cancer · doi:10.1002/ijc.31233 · Cited by 45
Kim, S., Pak, K., Kim, K., & Lee, J. S. (2018) · Spine · doi:10.1097/brs.0000000000002861 · Cited by 51
Sun, T., Tang, Y., Sun, D.-W., Bu, Q., & Li, P. (2018) · OncoTargets and Therapy · doi:10.2147/ott.s186230 · Cited by 48
Circulating microRNAs for the diagnosis of hepatocellular carcinoma
Peng, C., Ye, Y., Wang, Z., Guan, L., Bao, S., Li, B., & Li, W. (2018) · Digestive and Liver Disease · doi:10.1016/j.dld.2018.12.011 · Cited by 48
Koulidis, K., Veremis, Y., Anderson, C. N., & Heneghan, N. R. (2019) · Musculoskeletal Science and Practice · doi:10.1016/j.msksp.2019.01.001 · Cited by 53
Vázquez‐Morón, S., Jiménez, B. A., Jiménez‐Sousa, M. Á., Bellón, J. M., Ryan, P., & Resino, S. (2019) · Scientific Reports · doi:10.1038/s41598-019-41139-8 · Cited by 44
Angheben, A., Buonfrate, D., Cruciani, M., Jackson, Y., Alonso-Padilla, J., Gascón, J., Gobbi, F. G., Giorli, G., Anselmi, M., & Bisoffi, Z. (2019) · PLoS neglected tropical diseases · doi:10.1371/journal.pntd.0007271 · Cited by 44
Raffone, A., Travaglino, A., Santoro, A., Esposito, I., Angelico, G., Spadola, S., & Zannoni, G. F. (2019) · Pathology & Oncology Research · doi:10.1007/s12253-019-00727-9 · Cited by 45
18F-Facbc in Prostate Cancer: A Systematic Review and Meta-Analysis
Laudicella, R., Albano, D., Alongi, P., Argiroffi, G., Bauckneht, M., Baldari, S., Bertagna, F., Boero, M., Vincentis, G. D., Sole, A. D., et al. (2019) · Cancers · doi:10.3390/cancers11091348 · Cited by 44
Zhang, F., Liu, C., Chen, Q., Shao, S.-C., & Chen, S. (2019) · British Journal of Radiology · doi:10.1259/bjr.20190480 · Cited by 44
Suh, C. H., Kim, S. J., Jung, S. C., Choi, C. G., & Kim, H. S. (2019) · Scientific Reports · doi:10.1038/s41598-019-54583-3 · Cited by 45
Tsou, P., Ma, Y.-K., Wang, Y., Gillon, J. T., Rafael, J., & Deanehan, J. K. (2020) · The American Journal of Emergency Medicine · doi:10.1016/j.ajem.2020.04.071 · Cited by 48
Alnor, A. B., Sandberg, M. B., Gils, C., & Vinholt, P. J. (2020) · The Journal of Applied Laboratory Medicine · doi:10.1093/jalm/jfaa098 · Cited by 47
Microinstability of the hip: a systematic review of the imaging findings
Woodward, R. M., Vesey, R. M., Bacon, C. J., White, S., Brick, M. J., & Blankenbaker, D. G. (2020) · Skeletal Radiology · doi:10.1007/s00256-020-03516-7 · Cited by 45
Lin‐Martore, M., Kornblith, A. E., Kohn, M. A., & Gottlieb, M. A. (2020) · Western Journal of Emergency Medicine · doi:10.5811/westjem.2020.4.46241 · Cited by 50
Hyperspectral Imaging and the Retina: Worth the Wave?
Lemmens, S., Eijgen, J. V., Keer, K. V., Jacob, J. A., Moylett, S., Groef, L. D., Craenendonck, T. V., Boever, P. D., & Stalmans, I. (2020) · Translational Vision Science & Technology · doi:10.1167/tvst.9.9.9 · Cited by 51
Kamani, C. H., Allenbach, G., Jreige, M., Pavon, A. G., Meyer, M., Dardel, N. T., Firsova, M., Vieira, V. F., Boughdad, S., Lalonde, M. N., et al. (2020) · Diagnostics · doi:10.3390/diagnostics10100754 · Cited by 45
Accuracy of circulating microRNAs in diagnosis of sepsis: a systematic review and meta-analysis
Shen, X., Zhang, J., Huang, Y., Tong, J., Zhang, L., Zhang, Z., Yu, W., & Qiu, Y. (2020) · Journal of Intensive Care · doi:10.1186/s40560-020-00497-6 · Cited by 44
Boccardi, M., Dodich, A., Albanese, E., Gayet‐Ageron, A., Festari, C., Ashton, N. J., Bischof, G. N., Chiotis, K., Leuzy, A., Wolters, E. E., et al. (2021) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-020-05120-2 · Cited by 47
Sharma, C., Cococcia, S., Ellis, N., Parkes, J., & Rosenberg, W. M. (2021) · Journal of Gastroenterology and Hepatology · doi:10.1111/jgh.15482 · Cited by 49
Yang, B., Olsen, M., Vali, Y., Langendam, M. W., Takwoingi, Y., Hyde, C., Bossuyt, P. M., & Leeflang, M. (2021) · Journal of Clinical Epidemiology · doi:10.1016/j.jclinepi.2021.04.013 · Cited by 49
Self-citationTatum, R. C., McGowan, C. M., & Ireland, J. L. (2021) · The Veterinary Journal · doi:10.1016/j.tvjl.2021.105695 · Cited by 46
Shalof, H., Dimitri, P., Shuweihdi, F., & Offiah, A. C. (2021) · Bone · doi:10.1016/j.bone.2021.116013 · Cited by 53
Visual or visual-tactile examination to detect and inform the diagnosis of enamel caries
Macey, R., Walsh, T., Riley, P., Glenny, A., Worthington, H. V., O'Malley, L. A., Clarkson, J., & Ricketts, D. (2021) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd014546 · Cited by 73
Jones, T. L., Esa, M. S., Li, K. H. C., Krishnan, S. R. G., Elgallab, G. M., Pearce, M. S., Young, D. A., & Birrell, F. N. (2021) · Bone · doi:10.1016/j.bone.2021.116068 · Cited by 49
Mak, A. L., Lee, J., van Dijk, A., Vali, Y., Aithal, G. P., Schattenberg, J. M., Anstee, Q. M., Brosnan, M. J., Zafarmand, M. H., Ramsoekh, D., et al. (2021) · Biomedicines · doi:10.3390/biomedicines9121920 · Cited by 53
Self-citationSchroyen, G., Vissers, J., Smeets, A., Gillebert, C. R., Lemiere, J., Sunaert, S., Deprez, S., & Sleurs, C. (2022) · Translational Oncology · doi:10.1016/j.tranon.2021.101297 · Cited by 38
Vojnov, L., Carmona, S., Zeh, C. E., Markby, J. L., Boeras, D. I., Prescott, M. R., Mayne, A. L. H., Sawadogo, S., Adjé-Touré, C., Zhang, G., et al. (2022) · PLoS Medicine · doi:10.1371/journal.pmed.1004076 · Cited by 46
Non-invasive kinetic modelling approaches for quantitative analysis of brain PET studies
van der Weijden, C. W. J., Mossel, P., Bartels, A. L., Dierckx, R. A. J. O., Luurtsema, G., Lammertsma, A. A., Willemsen, A. T. M., & de Vries, E. F. J. (2023) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-022-06057-4 · Cited by 47
Lin, T., Gifford, W., Lan, Y., Qin, X., Liu, X., Wang, J., Yang, B., You, T., & Chen, K. (2017) · International Journal of Nursing Studies · doi:10.1016/j.ijnurstu.2017.03.005 · Cited by 44
Kaboudi, N., Firouzbakht, S., Eftekhar, M. S., Fayazbakhsh, F., Joharivarnoosfaderani, N., Ghaderi, S., Dehdashti, M., Kia, Y. M., Afshari, M., Gharamaleki, M. V., et al. (2024) · medRxiv · doi:10.22037/aaem.v12i1.2384 · Cited by 61
Chan, J. Y. C., Bat, B. K. K., Wong, A., Chan, T. K., Huo, Z., Yip, B. H. K., Kowk, T. C. Y., & Tsoi, K. K. F. (2022) · Neuropsychology Review · doi:10.1007/s11065-021-09523-2 · Cited by 43
Al-Hussain, G., Shuweihdi, F., Alali, H., Househ, M., & Abd-alrazaq, A. (2022) · Journal of Medical Internet Research · doi:10.2196/38472 · Cited by 37
“The risk of bias in the included studies was assessed using a revised tool for the Quality Assessment of Diagnostic Accuracy Studies (QUADAS)-2 [29], which is highly recommended by the Cochrane Collaboration [30].”
van Liere, E. L. S. A., van Dijk, L. J., Bosch, S., Vermeulen, L., Heymans, M. W., Burchell, G. L., de Meij, T. G. J., Ramsoekh, D., & de Boer, N. K. H. (2023) · European Journal of Cancer · doi:10.1016/j.ejca.2023.03.002 · Cited by 45
A systematic review on the performance of fracture risk assessment tools: FRAX, DeFRA, FRA-HS
Adami, G., Biffi, A., Porcu, G., Ronco, R., Alvaro, R., Bogini, R., Caputi, A. P., Cianferotti, L., Frediani, B., Gatti, D., et al. (2023) · Journal of Endocrinological Investigation · doi:10.1007/s40618-023-02082-8 · Cited by 45
Hu, W., Yii, F. S. L., Chen, R., Zhang, X., Shang, X., Kiburg, K., Woods, E., Vingrys, A. J., Zhang, L., Zhu, Z., et al. (2023) · Translational Vision Science & Technology · doi:10.1167/tvst.12.7.14 · Cited by 47
Validated Tools for Screening Sarcopenia: A Scoping Review
Lian, R., Jiang, G., Liu, Q., Shi, Q., Luo, S., Lu, J., & Yang, M. J. (2023) · Journal of the American Medical Directors Association · doi:10.1016/j.jamda.2023.06.036 · Cited by 46
Zhong, J., Mao, S., Chen, H., Wang, Y., Yin, Q., Cen, Q., Lu, J. A., Yang, J., Hu, Y., Xing, Y., et al. (2024) · European Radiology · doi:10.1007/s00330-024-11160-1 · Cited by 49
“For diagnostic performance and category-wise malignancy rates studies, we assessed their quality per modi fi ed Quality Assessment of Diagnostic Accuracy Studies (QUADAS-2) [31] with speci fi ed signal questions for this review (Supplementary Table S2).”
Țâru, M.-G., Leucuta, D.-C., Lupșor‐Platon, M., Turco, L., Ferri, S., Hashim, A., Orasan, O. H., Procopeț, B., Ştefănescu, H., Morelli, M. C., et al. (2024) · Hepatology · doi:10.1097/hep.0000000000001190 · Cited by 51
“The methodological quality was assessed with the QUADAS-2 tool, [28] as summarized in Supplemental Table S3, http://links.lww.com/HEP/J663, Supplemental Figures S1, S2, http://links.lww.com/HEP/J663.”
Chuang, C.-J., Yeh, H.-T., Niu, K.-Y., Chen, C., Seak, C., & Yen, C. (2025) · European Journal of Emergency Medicine · doi:10.1097/mej.0000000000001235 · Cited by 52
Systematic Review and Meta-Analysis of Outcomes after Cardiopulmonary Arrest in Childhood
Phillips, R. S., Scott, B., Carter, S. J., Taylor, M., Peirce, E., Davies, P., & Maconochie, I. K. (2015) · PLoS ONE · doi:10.1371/journal.pone.0130327 · Cited by 45
Kokkinou, M., Beishon, L., Smailagic, N., Noel-Storr, A. H., Hyde, C., Ukoumunne, O. C., Worrall, R., Hayen, A., Desai, M., Ashok, A. H., et al. (2021) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd010945.pub2 · Cited by 53
Hew, M. J., Corcoran, J. P., Harriss, E., Rahman, N. M., & Mallett, S. (2015) · BMJ Open · doi:10.1136/bmjopen-2015-007838 · Cited by 43
Self-citationSentinel node assessment for diagnosis of groin lymph node involvement in vulval cancer
Lawrie, T. A., Patel, A., Martin‐Hirsch, P. L., Bryant, A., Ratnavelu, N. D., Naik, R., & Ralte, A. M. (2014) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd010409.pub2 · Cited by 48
Verdoodt, F., Jiang, X., Williams, M., Schnatz, P. F., & Arbyn, M. (2015) · International Journal of Cancer · doi:10.1002/ijc.29424 · Cited by 45
A systematic review of p16/Ki‐67 immuno‐testing for triage of low grade cervical cytology
Kisser, A., & Zechmeister‐Koss, I. (2014) · BJOG An International Journal of Obstetrics & Gynaecology · doi:10.1111/1471-0528.13076 · Cited by 47
Hassanzadeh‐Rad, A., Yousefifard, M., Katal, S., Asady, H., Fard‐Esfahani, A., Jafari, A. M., & Hosseini, M. (2015) · Journal of Gastroenterology and Hepatology · doi:10.1111/jgh.13247 · Cited by 47
Alcázar, J. L., Dominguez-Piriz, J., Juez, L., Caparros, M., & Jurado, M. (2016) · International Journal of Gynecological Cancer · doi:10.1097/igc.0000000000000618 · Cited by 43
Laurenti, P., Raponi, M., de Waure, C., Marino, M., Ricciardi, W., & Damiani, G. (2016) · BMC Infectious Diseases · doi:10.1186/s12879-016-1461-y · Cited by 43
Kubo, T., Furuta, T., Johan, M. P., Adachi, N., & Ochi, M. (2016) · Skeletal Radiology · doi:10.1007/s00256-016-2410-y · Cited by 43
da Silva, A. K. F., Barbosa, M. P. D. C. D. R., Vanderlei, F. M., Christófaro, D. G. D., & Vanderlei, L. C. M. (2016) · Annals of Noninvasive Electrocardiology · doi:10.1111/anec.12372 · Cited by 55
Hu, Y., Liao, Q., Cao, S., Gao, X., & Zhao, Y. (2016) · Endocrine · doi:10.1007/s12020-016-0997-3 · Cited by 43
Zheng, D., Guo, Z., Schroder, P. M., Zheng, Z., Lü, Y., Gu, J., & He, X. (2016) · Radiology · doi:10.1148/radiol.2016152571 · Cited by 43
Chen, J., Chen, Y., Gu, L., Li, X., Gao, Y., Lyu, X., Chen, L., Luo, G., Wang, L., Xie, Y., et al. (2016) · Oncotarget · doi:10.18632/oncotarget.11101 · Cited by 45
Tian, W., Hao, S., Gao, B., Jiang, Y., Zhang, X., Zhang, S., Guo, L., Yan, J., & Luo, D. (2016) · Cellular Physiology and Biochemistry · doi:10.1159/000452513 · Cited by 43
Yung, D. E., Sykes, C. R., & Koulaouzidis, A. (2016) · Expert Review of Gastroenterology & Hepatology · doi:10.1080/17474124.2017.1257384 · Cited by 43
Sheikhbahaei, S., Marcus, C. V., Fragomeni, R. S., Rowe, S. P., Javadi, M. S., & Sólnes, L. B. (2016) · Journal of Nuclear Medicine · doi:10.2967/jnumed.116.183905 · Cited by 43
González, O. R., Tenías, J. M., Arias, Á., & Lucendo, A. J. (2017) · Health Services Research · doi:10.1111/1475-6773.12691 · Cited by 43
“We used the Quality Assessment of Diagnostic Accuracy Studies 2 (QUADAS-2) statement (Whiting et al. 2011) to evaluate the methodological and reporting quality of all the retrieved studies with respect to risk of bias and applicability concerns.”
Li, B., Sun, Z., Li, X., Li, X., Wang, H., Chen, W., Chen, P., Qiao, M., & Mao, Y. (2017) · Archives of Medical Science · doi:10.5114/aoms.2017.67279 · Cited by 43
Yoon, H. M., Suh, C. H., Kim, J. R., Lee, J. S., Jung, A. Y., Kim, K. M., & Cho, Y. A. (2017) · Archives of Pediatrics and Adolescent Medicine · doi:10.1001/jamapediatrics.2017.3400 · Cited by 48
Wang, Z., Pianosi, P. T., Keogh, K. A., Zaiem, F., Alsawas, M., Alahdab, F., Almasri, J., Mohammed, K. S., Larrea-Mantilla, L., Farah, W. H., et al. (2017) · Mayo Clinic Proceedings · doi:10.1016/j.mayocp.2017.11.012 · Cited by 44
Soluble TREM-1 as a predictive factor of neonatal sepsis: a meta-analysis
Bellos, I., Fitrou, G., Daskalakis, G., Thomakos, N., Papantoniou, N. E., & Pergialiotis, V. (2018) · Inflammation Research · doi:10.1007/s00011-018-1149-4 · Cited by 43
On behalf of the Dutch post-mortem imaging guideline group, Sonnemans, L. J. P., Vester, M. E. M., Kolsteren, E. E. M., Erwich, J. J., Nikkels, P. G. J., Kint, P. A. M., van Rijn, R. R., & Klein, W. M. (2018) · European Journal of Pediatrics · doi:10.1007/s00431-018-3135-9 · Cited by 46
Iwase, S., Nakada, T., Hattori, N., Takahashi, W., Takahashi, N., Aizimu, T., Yoshida, M., Morizane, T., & Oda, S. (2018) · The American Journal of Emergency Medicine · doi:10.1016/j.ajem.2018.05.040 · Cited by 47
“The methodological quality of the studies was assessed using the Quality Assessment of Diagnostic Accuracy Studies (QUADAS-2) tool [18].”
Assessment of skin temperature during regional anaesthesia—What the anaesthesiologist should know
Hermanns, H., Werdehausen, R., Hollmann, M. W., & Stevens, M. F. (2018) · Acta Anaesthesiologica Scandinavica · doi:10.1111/aas.13176 · Cited by 43
The importance of stool DNA methylation in colorectal cancer diagnosis: A meta-analysis
Shariatpanahi, A. M., Yassi, M., Nouraie, M. S., Sahebkar, A., Tabrizi, F. V., & Kerachian, M. A. (2018) · PLoS ONE · doi:10.1371/journal.pone.0200735 · Cited by 45
Wardrope, A., Newberry, E., & Reuber, M. (2018) · Seizure · doi:10.1016/j.seizure.2018.08.012 · Cited by 49
Zhou, M., Shuju, S., Wu, S., Duan, T., Chen, L., Ye, J., & Xiao, J. (2018) · Scientific Reports · doi:10.1038/s41598-018-35288-5 · Cited by 46
Suh, C. H., Park, J. E., Jung, S. C., Choi, C. G., Kim, S. J., & Kim, H. S. (2019) · Neuroradiology · doi:10.1007/s00234-018-02152-2 · Cited by 44
Chest pain in general practice: a systematic review of prediction rules
Harskamp, R. E., Laeven, S. C., Himmelreich, J. C. L., Lucassen, W. A. M., & van Weert, H. C. P. M. (2019) · BMJ Open · doi:10.1136/bmjopen-2018-027081 · Cited by 43
Chung, S. R., Choi, Y. J., Suh, C. H., Lee, J. H., & Baek, J. H. (2019) · Korean Journal of Radiology · doi:10.3348/kjr.2018.0446 · Cited by 43
Does subtalar instability really exist? A systematic review
Michels, F., Clockaerts, S., Bauwhede, J. V. D., Stockmans, F., & Matricali, G. A. (2019) · Foot and Ankle Surgery · doi:10.1016/j.fas.2019.02.001 · Cited by 43
Basterfield, C., Hester, R., & Bowden, S. C. (2019) · Neuropsychology · doi:10.1037/neu0000552 · Cited by 46
Arshad, Z., Alturkistani, A., Brindley, D. A., Lam, C., Foley, K., & Meinert, E. (2019) · JMIR Public Health and Surveillance · doi:10.2196/14216 · Cited by 45
Singarayer, R., Mete, Ö., Perrier, L., Thabane, L., Asa, S. L., Uum, S. H. M. V., Ezzat, S., Goldstein, D. P., & Sawka, A. M. (2019) · Endocrine Pathology · doi:10.1007/s12022-019-09585-2 · Cited by 44
Xu, X.-Y., Wang, W.-S., Zhang, Q., Li, J., Sun, J.-B., Qin, T., & Liu, H.-B. (2019) · World Journal of Clinical Cases · doi:10.12998/wjcc.v7.i15.2022 · Cited by 44
Zhang, X., & Liang, H. (2019) · Medicine · doi:10.1097/md.0000000000016360 · Cited by 44
“The quality of the included studies made by the two researchers was assessed according to the quality assessment of diagnostic accuracy studies (QUADAS-2).([18]) The QUADAS-2 includes the following domains: patient selection, reference standard, index text and flow of patients through the study/timing of index tests,…”
Guidance for Studies Evaluating the Accuracy of Tuberculosis Triage Tests
Nathavitharana, R. R., Yoon, C., Macpherson, P., Dowdy, D. W., Cattamanchi, A., Somoskovi, A., Broger, T., Ottenhoff, T. H. M., Arinaminpathy, N., Lonnroth, K., et al. (2019) · The Journal of Infectious Diseases · doi:10.1093/infdis/jiz243 · Cited by 45
Shakoor, D., Demehri, S., Roemer, F. W., Lœuille, D., Felson, D. T., & Guermazi, A. (2019) · Osteoarthritis and Cartilage · doi:10.1016/j.joca.2019.10.008 · Cited by 45
Lan, J., Wen, J., Cao, S.-Q., Yin, T., Jiang, B., Lou, Y., Zhu, J., An, X., Suo, H., Li, D., et al. (2019) · British Journal of Dermatology · doi:10.1111/bjd.18722 · Cited by 47
Detecting delirium in patients with acute stroke: a systematic review of test accuracy
Mansutti, I., Saiani, L., & Palese, A. (2019) · BMC Neurology · doi:10.1186/s12883-019-1547-4 · Cited by 47
Zoonotic causes of febrile illness in malaria endemic countries: a systematic review
Halliday, J. E. B., Carugati, M., Snavely, M. E., Allan, K. J., Beamesderfer, J., Ladbury, G. A. F., Hoyle, D. V., Holland, P., Crump, J. A., Cleaveland, S., et al. (2020) · The Lancet Infectious Diseases · doi:10.1016/s1473-3099(19)30629-2 · Cited by 48
Kahwati, L. C., Clark, R., Berkman, N. D., Urrutia, R. P., Patel, S. V., Zeng, J. J., & Viswanathan, M. (2020) · JAMA · doi:10.1001/jama.2020.0233 · Cited by 48
Yoon, S., Speyer, R., Cordier, R., Aunio, P., & Hakkarainen, A. M. (2020) · Trauma Violence & Abuse · doi:10.1177/1524838020915591 · Cited by 49
Ma, H., Yan, W., & Liu, J. (2020) · Medical Ultrasonography · doi:10.11152/mu-2485 · Cited by 50
Mouselimis, D., Tsarouchas, A., Pagourelias, E., Bakogiannis, C., Theofilogiannakos, E. K., Loutradis, C., Fragakis, N., Vassilikos, V. P., & Papadopoulos, C. E. (2020) · Hellenic Journal of Cardiology · doi:10.1016/j.hjc.2020.04.008 · Cited by 45
Kim, T., Woo, S., Han, S., Suh, C. H., Ghafoor, S., Hricak, H., & Vargas, H. A. (2020) · Korean Journal of Radiology · doi:10.3348/kjr.2019.0842 · Cited by 46
Chae, S. Y., Son, H. J., Lee, D. Y., Shin, E., Oh, J. S., Seo, S. Y., Baek, S., Kim, J. Y., Na, S. J., & Moon, D. H. (2020) · EJNMMI Research · doi:10.1186/s13550-020-00643-z · Cited by 45
Zhang, Q., Xi, Y., Li, D., Yuan, Z., & Dong, J. (2020) · Journal of Orthopaedic Surgery and Research · doi:10.1186/s13018-020-01748-w · Cited by 43
Zhang, X., He, T., & Shen, W. (2020) · Experimental and Therapeutic Medicine · doi:10.3892/etm.2020.9043 · Cited by 58
Latoszek, B. B. V., Kim, G., Hernández, J. D., Hosokawa, K., Englert, M., Neumann, K., & Hetjens, S. (2020) · Clinical Otolaryngology · doi:10.1111/coa.13629 · Cited by 49
Liang, J., Zeng, S., Li, Z., Kong, Y., Meng, T., Zhou, C., Chen, J., Wu, Y., & He, N. (2020) · Frontiers in Oncology · doi:10.3389/fonc.2020.585486 · Cited by 43
Figueiredo, V. R., Cardoso, P. F. G., Jacomelli, M., Santos, L. M., Minata, M. K., & Terra, R. M. (2020) · Jornal Brasileiro de Pneumologia · doi:10.36416/1806-3756/e20190221 · Cited by 43
“(22) Homogeneous prospective randomized studies were considered eligible.”
Yang, R., Zou, X., Zeng, H., Zhao, Y., & Ma, X. (2020) · Frontiers in Oncology · doi:10.3389/fonc.2020.598225 · Cited by 43
Diagnostic Test Accuracy of the Red Reflex Test for Ocular Pathology in Infants: A Meta-analysis
Subhi, Y., Schmidt, D. C., Al‐Bakri, M., Bach‐Holm, D., & Kessel, L. (2020) · JAMA Ophthalmology · doi:10.1001/jamaophthalmol.2020.4854 · Cited by 53
Metabolomics for Diagnosis and Prognosis of Uterine Diseases? A Systematic Review
Tokarz, J., Adamski, J., & Rižner, T. L. (2020) · Journal of Personalized Medicine · doi:10.3390/jpm10040294 · Cited by 54
Vardarli, I., Weber, M., Weidemann, F., Führer, D., Herrmann, K., & Görges, R. (2021) · Endocrine Connections · doi:10.1530/ec-21-0030 · Cited by 44
“According to the QUADAS-2 tool (22, 23), the methodological quality of the included trials was acceptable (Fig.”
Influential
Metadata
- Authors
- Whiting, P. F., Rutjes, A. W. S., Westwood, M. E., Mallett, S., Deeks, J. J., Reitsma, J. B., Leeflang, M. M. G., Sterne, J. A. C., Bossuyt, P. M. M., & the QUADAS-2 Group*
- Affiliations
- University of Bern (CH)
- Corresponding author
- Whiting, Penny F.
- ORCID
- Venue
- Annals of Internal Medicine
- Publisher
- American College of Physicians
- Published
- 2011-10-18
- Volume
- 155
- Issue
- 8
- Pages
- 529-536
- ISSN
- 0003-4819 (ISSN-L)
- 1539-3704
- OpenAlex
- W2107638293
- Semantic Scholar
- 8a5d0b5a9271ea14bcb8479bc32d3844a80655b9
- Cited by
- 14,199
- References
- 18
- Citations by year
- 2026: 1484 · 2025: 1569 · 2024: 1524 · 2023: 1305 · 2022: 1420 · 2021: 1514 · 2020: 1245 · 2019: 955 · 2018: 767 · 2017: 637 · 2016: 580 · 2015: 528 · 2014: 363 · 2013: 217 · 2012: 75
- FWCI
- 224.36
- Type
- journal article
- Language
- en
- Open access
- green
- hdl.handle.net
- Licence
- cc-by
- www.acpjournals.org/journal/aim/text-and-data-mining (tdm)
- Locations
- Annals of Internal Medicine (publishedVersion)
- PubMed (publishedVersion)
- Pure Amsterdam UMC (publishedVersion)
- Data Archiving and Networked Services (DANS) (submittedVersion)
- Florence Research (University of Florence) (submittedVersion)
- IRIS UNIMORE (University of Modena and Reggio Emilia) (submittedVersion, cc-by)
- University of Birmingham Research Portal (University of Birmingham) (submittedVersion)
- Bristol Research (University of Bristol) (submittedVersion)
- Funders
- Cancer Research UK
- Topics
- Social Sciences › Decision Sciences › Statistics, Probability and Uncertainty › Meta-analysis and systematic reviews
- Physical Sciences › Mathematics › Statistics and Probability › Statistical Methods in Epidemiology
- Health Sciences › Medicine › Public Health, Environmental and Occupational Health › Clinical practice guidelines implementation
- Keywords
- QUADAS-2, diagnostic accuracy studies, quality assessment, risk of bias, applicability, patient selection, index tests, reference materials, flowcharts, systematic reviews
- MeSH terms
- Diagnosis, Humans, Quality Control, Surveys and Questionnaires, Reference Standards, Review Literature as Topic, Time Factors, Bias, Patient Selection, Evidence-Based Medicine
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
A language model drew the claims from the paper on 2026-11-23, under version 3 of the claim definition (model deepseek-v4.1-flash, prompt extract-v3).
A second model labelled each claim on 2026-11-23 (model jev-1.13-20260917, definition revision gold-guideline-v0.2).
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.