QUADAS-2: A Revised Tool for the Quality Assessment of Diagnostic Accuracy Studies
Open accessThe DOI matches its Crossref record; 18 of the 18 references it cites were found in a registry or an index; none of the 21 sources its claims cite is checked for support yet.
Abstract
In 2003, the QUADAS tool for systematic reviews of diagnostic accuracy studies was developed. Experience, anecdotal reports, and feedback suggested areas for improvement; therefore, QUADAS-2 was developed. This tool comprises 4 domains: patient selection, index test, reference standard, and flow and timing. Each domain is assessed in terms of risk of bias, and the first 3 domains are also assessed in terms of concerns regarding applicability. Signalling questions are included to help judge risk of bias. The QUADAS-2 tool is applied in 4 phases: summarize the review question, tailor the tool and produce review-specific guidance, construct a flow diagram for the primary study, and judge bias and applicability. This tool will allow for more transparent rating of bias and applicability of primary diagnostic accuracy studies.
Overview
CoChat Summary
TL;DR
QUADAS-2 is a revised tool for assessing risk of bias and applicability in diagnostic accuracy studies, developed through a 4-stage evidence-based consensus process. It replaces the original QUADAS “yes/no/unclear” quality rating with domain-level judgments of low, high, or unclear risk of bias and concerns about applicability.
Key findings
- QUADAS-2 separates “quality” into risk of bias and concerns regarding applicability, defining quality as the degree to which diagnostic accuracy estimates avoided bias and the extent to which primary studies are applicable to the review question.
- The tool has 4 key domains—patient selection, index test, reference standard, and flow and timing—with the first 3 also assessed for applicability; it is completed in 4 phases and uses signaling questions to help judge risk of bias.
- Development drew on 4 reviews: 54 diagnostic accuracy reviews published between 2007 and 2009, structured feedback from 64 systematic reviewers who had used QUADAS, 101 studies on sources of bias and variation, and 8 studies evaluating QUADAS; a 1-day consensus meeting had 24 attendees, and piloting occurred in 5 reviews.
- Interrater reliability varied considerably, with better agreement on applicability than on risk of bias; all participants preferred QUADAS-2 to the original tool, but the authors could not currently include criteria for studies comparing multiple index tests because the evidence base was insufficient.
Methods
- Tool development followed Moher and colleagues’ 4-stage approach: define the scope, review the evidence base, hold a face-to-face consensus meeting, and refine through piloting.
- A steering group of 9 experts set the scope; the consensus meeting was held on 21 September 2010 in Birmingham, United Kingdom, with 24 attendees who split into groups of 4 to 6 participants; multiple rounds of piloting used online questionnaires and other feedback, including pairs of reviewers piloting QUADAS-2 in 5 reviews.
- No primary statistical analysis was reported; the work synthesized evidence reviews, consensus decisions, and pilot feedback to produce and refine the tool.
Limitations
- Stated: the authors decided they cannot currently include criteria for assessing studies that compare multiple index tests within QUADAS-2 because of the limited evidence base on risk of bias and sources of variation in such studies, and they plan future work on this topic.
- Stated: piloting showed poor interrater reliability and problems applying the domain on comparative accuracy studies; interrater reliability varied considerably overall, with better agreement on applicability than on risk of bias.
- Evident from the text: full details of the 4 evidence reviews were to be published separately, and the main text reports no quantitative reliability estimates, referring instead to an Appendix Table.
Model-written summary. Check it against the paper before relying on it.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
0 Valid · 0 Not valid · 16 Not checked · 24 Own results and interpretations
In the paper
“In a review on anti-cyclic citrullinated peptide antibodies for diagnosing rheumatoid arthritis (10), we found that some studies enrolled consecutive participants with confirmed diagnoses. In these studies, testing for anticyclic citrullinated peptide antibody showed greater sensitivity than in studies that included patients with suspected disease but an unconfirmed diagnosis (that is, difficult-t”
§ QUADAS-2: A Revised Tool for the Quality Assessment of Diagnostic Accuracy Studies > Signaling question 2: Was a case-control design avoided? Signaling question 3: Did the study avoid inappropriate exclusions?
What the sources say
- Not matchedcites [10]
The reference list we hold has no entry [10].
plainstates an association- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Not matched
A statement the paper makes itself — it cites no source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“Studies that make inappropriate exclusions (for example, not including”
§ QUADAS-2: A Revised Tool for the Quality Assessment of Diagnostic Accuracy Studies > Signaling question 2: Was a case-control design avoided? Signaling question 3: Did the study avoid inappropriate exclusions?
hedgedstates a possible cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
None of the sources cited for this claim could be matched to a paper, so there is nothing to check it against.
In the paper
“Because the accuracy of a test may depend on where it will be used in the diagnostic pathway, review authors are asked to describe patients in terms of setting, intended use of the index test, patient presentation, and previous testing (8,9).”
§ QUADAS-2: A Revised Tool for the Quality Assessment of Diagnostic Accuracy Studies > Phase 1: Review Question
What the sources say
- Not matchedcites [8]
The reference list we hold has no entry [8].
- Not matchedcites [9]
The reference list we hold has no entry [9].
hedgedstates a possible cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Not matched
In the paper
“Development of QUADAS-2 was based on the 4-stage approach proposed by Moher and colleagues (4): define the scope, review the evidence base, hold a face-to-face consensus meeting, and refine the tool through piloting.”
§ QUADAS-2: A Revised Tool for the Quality Assessment of Diagnostic Accuracy Studies > METHODS
What the sources say
- Not matchedcites [4]
The reference list we hold has no entry [4].
plainstates a cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: unclear — It is unclear whether the paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Not matched
None of the sources cited for this claim could be matched to a paper, so there is nothing to check it against.
In the paper
“Studies enrolling participants with known disease and a control group without the condition may similarly exaggerate diagnostic accuracy (7,11).”
§ QUADAS-2: A Revised Tool for the Quality Assessment of Diagnostic Accuracy Studies > Signaling question 2: Was a case-control design avoided? Signaling question 3: Did the study avoid inappropriate exclusions?
What the sources say
- Not matchedcites [7]
The reference list we hold has no entry [7].
- Not matchedcites [11]
The reference list we hold has no entry [11].
hedgedstates a possible cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Not matched
10 more claims
Create a free account to see all 40 claims and every source verdict.
- Probably not a substantial claim. 19
- It may state two separate claims as one. 16
- The quote only partly states this claim. 2
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“We assessed the study-level risk of bias with the QUADAS-2 tool”
In the citing paper
“We developed a revised risk-of-bias assessment tool to address these issues, incorporate advances in assessment of risk of bias used in other recently developed tools, 9 10 and integrate recent developments in estimation of intervention effects from randomised trials. 11”
From RoB 2: a revised tool for assessing risk of bias in randomised trials (2019) · cites this paper as [10]
In the citing paper
“Two reviewers independently assessed the quality of the included studies with the Quality Assessment of Diagnostic Accuracy Studies (Quadas-2) [33].”
From High-standard predictive equations for estimating body composition using bioelectrical impedance analysis: a systematic review (2024) · cites this paper as [33]
In the citing paper
“The quality of the selected studies was rigorously assessed using the Checklist for Artificial Intelligence in Medical Imaging (CLAIM) alongside the Quality Assessment of Diagnostic Accuracy Studies-2 (QUADAS-2).23,24”
From Artificial Intelligence Detection and Segmentation Models: A Systematic Review and Meta-Analysis of Brain Tumors in Magnetic Resonance Imaging (2024) · cites this paper as [24]
In the citing paper
“The methodological quality of each selected study was assessed according to the Quality Assessment of Diagnostic Accuracy Studies (QUADAS-2) checklist [15]”
From The diagnostic accuracy of digital, infrared and mercury-in-glass thermometers in measuring body temperature: a systematic review and network meta-analysis (2021) · cites this paper as [15]
20 more claims about this paper
Create a free account to see every claim other papers make about this one.
Citations
Cites
The Cochrane Collaboration's tool for assessing risk of bias in randomised trials
Higgins, J. P. T., Altman, D. G., Gotzsche, P. C., Juni, P., Moher, D., Oxman, A. D., Savovic, J., Schulz, K. F., Weeks, L., Sterne, J. A. C., et al. (2011) · BMJ · doi:10.1136/bmj.d5928 · Cited by 33,817
Self-citationWhiting, P., Rutjes, A. W., Reitsma, J. B., Bossuyt, P. M., & Kleijnen, J. (2003) · BMC Medical Research Methodology · doi:10.1186/1471-2288-3-25 · Cited by 3,592
Self-citationThe Hazards of Scoring the Quality of Clinical Trials for Meta-analysis
Jüni, P. (1999) · JAMA · doi:10.1001/jama.282.11.1054 · Cited by 1,981
Empirical evidence of design-related bias in studies of diagnostic tests.
Lijmer, J. G. (1999) · JAMA · doi:10.1001/jama.282.11.1061 · Cited by 1,861 · cited 2×
“Studies enrolling participants with known disease and a control group without the condition may similarly exaggerate diagnostic accuracy (7, 11).”
BackgroundGuidance for Developers of Health Research Reporting Guidelines
Moher, D., Schulz, K. F., Simera, I., & Altman, D. G. (2010) · PLoS Medicine · doi:10.1371/journal.pmed.1000217 · Cited by 1,437
Systematic Reviews of Diagnostic Test Accuracy
Leeflang, M. M. G., Deeks, J. J., Gatsonis, C., & Bossuyt, P. M. M. (2008) · Annals of Internal Medicine · doi:10.7326/0003-4819-149-12-200812160-00008 · Cited by 1,124
Self-citationSources of Variation and Bias in Studies of Diagnostic Accuracy: A Systematic Review
Whiting, P., Rutjes, A. W. S., Reitsma, J. B., Glas, A. S., Bossuyt, P. M. M., & Kleijnen, J. (2004) · Annals of Internal Medicine · doi:10.7326/0003-4819-140-3-200402030-00010 · Cited by 798 · cited 4×
“The third review was an update on sources of bias and variation in diagnostic accuracy studies that included 101 studies (7).”
BackgroundInfluentialSelf-citationEvaluation of QUADAS, a tool for the quality assessment of diagnostic accuracy studies
Whiting, P. F., Weswood, M. E., Rutjes, A. W., Reitsma, J. B., Bossuyt, P. N., & Kleijnen, J. (2006) · BMC Medical Research Methodology · doi:10.1186/1471-2288-6-9 · Cited by 769
Self-citationLeeflang, M. M. G., Moons, K. G. M., Reitsma, J. B., & Zwinderman, A. H. (2008) · Clinical Chemistry · doi:10.1373/clinchem.2007.096032 · Cited by 346 · cited 1×
“Test performance is likely to be poorer in an independent sample of patients in whom the same threshold is used (12).”
BackgroundSelf-citationNo role for quality scores in systematic reviews of diagnostic accuracy studies
Whiting, P., Harbord, R., & Kleijnen, J. (2005) · BMC Medical Research Methodology · doi:10.1186/1471-2288-5-19 · Cited by 337
Self-citation
Cited by
Items 3,201–3,300 of 14,770
Saueressig, T., Owen, P. J., Diemer, F., Zebisch, J., & Belavý, D. L. (2021) · Journal of Orthopaedic and Sports Physical Therapy · doi:10.2519/jospt.2021.10469 · Cited by 49
Transoesophageal echocardiography in cardiac arrest: A systematic review
Hussein, L., Rehman, M. A., Jelic, T. M., Berdnikov, A., Teran, F., Richards, S., Askin, N., & Jarman, B. (2021) · Resuscitation · doi:10.1016/j.resuscitation.2021.08.001 · Cited by 43
Husain, A. A., Solomons, M., Stadlinger, B., Pejicic, R., Winklhofer, S. F.-X., Piccirelli, M., & Valdec, S. (2021) · Diagnostics · doi:10.3390/diagnostics11091657 · Cited by 43
Kim, D., Chung, S., Kang, W. S., & Kim, J. S. (2021) · Diagnostics · doi:10.3390/diagnostics12010049 · Cited by 50
Hearables, in-ear sensing devices for bio-signal acquisition: a narrative review
Ne, C. K. H., Muzaffar, J., Amlani, A., & Bance, M. (2021) · Expert Review of Medical Devices · doi:10.1080/17434440.2021.2014321 · Cited by 49
Thelissen, A. A. B., Jurgenliemk-Schulz, I. M., van der Leij, F., Peters, M., Gerestein, C. G., Zweemer, R. P., & van Rossum, P. S. N. (2021) · Gynecologic Oncology · doi:10.1016/j.ygyno.2021.12.026 · Cited by 43
Diagnostic Accuracy of CT Texture Analysis in Adrenal Masses: A Systematic Review
Crimì, F., Quaia, E., Cabrelle, G., Zanon, C., Pepe, A., Regazzo, D., Tizianel, I., Scaroni, C., & Ceccato, F. (2022) · International Journal of Molecular Sciences · doi:10.3390/ijms23020637 · Cited by 48
Dumitrescu, E. A., Ungureanu, B. S., Cazacu, I. M., Florescu, L. M., Streba, L., Croitoru, V. M., Sur, D. G., Croitoru, A. E., Turcu-Ştiolică, A., & Lungulescu, C. V. (2022) · Diagnostics · doi:10.3390/diagnostics12020309 · Cited by 51
Fernando, S. M., Tran, A., Cheng, W., Rochwerg, B. N., Strauss, S. A., Mutter, E., McIsaac, D. I., Kyeremanteng, K., Kubelik, D., Jetty, P., et al. (2022) · Academic Emergency Medicine · doi:10.1111/acem.14475 · Cited by 49
Arshadi, M., Fardsanei, F., Deihim, B., Farshadzadeh, Z., Nikkhahi, F., Khalili, F., Sotgiu, G., Bonjar, A. H. S., Centis, R., Migliori, G. B., et al. (2022) · Frontiers in Medicine · doi:10.3389/fmed.2022.870738 · Cited by 45
Seid, G., Alemu, A., Tsedalu, T., & Dagne, B. (2022) · IJID Regions · doi:10.1016/j.ijregi.2022.06.004 · Cited by 52
(2019) · Europe PMC (PubMed Central) · Cited by 65
van Zanten, S. E. M. V., Pieterman, K. J., Wijnhoven, B. P. L., Pruis, I. J., Koerkamp, B. G., van Driel, L. M. J. W., Verburg, F. A., & Thomeer, M. G. J. (2022) · Diagnostics · doi:10.3390/diagnostics12081958 · Cited by 49
Jarman, B., McDermott, C., Colclough, A., Bøtker, M. T., Knudsen, L., Harris, T., Albaroudi, B., Albaroudi, O., Haddad, M., Darke, R., et al. (2022) · Ultraschall in der Medizin - European Journal of Ultrasound · doi:10.1055/a-1882-5615 · Cited by 43
Cervical Spine Clearance in Obtunded Patients After Blunt Traumatic Injury
Badhiwala, J. H., Lai, C. K., Alhazzani, W. A., Farrokhyar, F., Nassiri, F., Meade, M. O., Mansouri, A., Sne, N., Aref, M., Murty, N., et al. (2015) · Annals of Internal Medicine · doi:10.7326/m14-2351 · Cited by 43
Munir, S., Patil, K., Miller, E., Uleryk, E. M., Twilt, M., Spiegel, L. R., & Doria, A. S. (2013) · American Journal of Roentgenology · doi:10.2214/ajr.12.10475 · Cited by 45
Gimenez, T., Piovesan, C., Braga, M. M., Raggio, D. P., Deery, C., Ricketts, D. N. J., Ekstrand, K., & Mendes, F. M. (2015) · Caries Research · doi:10.1159/000365948 · Cited by 49
Alzheimer’s Disease Dementia Guidelines for Diagnostic Testing: A Systematic Review
Arévalo-Rodríguez, I., Pedraza, O. L., Rodríguez, A., Sánchez, E., Gich, I. J., Solà, I., Bonfill, X., & Alonso‐Coello, P. (2013) · American Journal of Alzheimer s Disease & Other Dementias® · doi:10.1177/1533317512470209 · Cited by 50
Wang, Z., Chen, J., Liu, J., & Qin, X. (2015) · European Journal of Clinical Investigation · doi:10.1111/eci.12577 · Cited by 43
Accuracy of magnetic resonance venography in diagnosing cerebral venous sinus thrombosis
Gao, L., Xu, W., Li, T., Yu, X., Cao, S., Xu, H., Yan, F., & Chen, G. (2018) · Thrombosis Research · doi:10.1016/j.thromres.2018.05.012 · Cited by 43
Barreñada, L., Ledger, A., Dhiman, P., Collins, G., Wynants, L., Verbakel, J. Y., Timmerman, D., Valentin, L., & Van Calster, B. (2024) · BMJ Medicine · doi:10.1136/bmjmed-2023-000817 · Cited by 42
Xu, Y., Ding, W., Wang, Y., Tan, Y., Xi, C., Ye, N., Wu, D., & Xu, X. (2021) · PLOS ONE · doi:10.1371/journal.pone.0246892 · Cited by 42
Applications of Artificial Intelligence in Dental Medicine: A Critical Review
Sitaras, S., Tsolakis, I. A., Gelsini, M., Tsolakis, A. I., Schwendicke, F., Wolf, T. G., & Perlea, P. (2025) · International Dental Journal · doi:10.1016/j.identj.2024.11.009 · Cited by 42
Huang, X. C., Hu, X., Wang, X. R., Zhou, C. X., Wang, F. F., Yang, S., & Wang, G. Y. (2018) · Irish Journal of Medical Science (1971 -) · doi:10.1007/s11845-018-1781-6 · Cited by 42
Miranda, F., Arévalo-Rodríguez, I., Díaz, G., Gonzalez, F., Plana, N., Zamora, J., Quinn, T., & Pamela Serón, S. (2018) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd013126 · Cited by 44
de Moura, D. T. H., McCarty, T. R., Ribeiro, I. B., Funari, M. P., de Oliveira, P. V. A. G., Neto, A. A. D. M., do Monte, E. S., Tustumi, F., Bernardo, W. M., de Moura, E. G. H., et al. (2020) · Clinics · doi:10.6061/clinics/2020/e2212 · Cited by 44
“To evaluate the methodologic quality of individual studies, quality assessment of diagnostic accuracy studies (QUADAS-2) was performed (34).”
Chornenki, N. L. J., Poorzargar, K., Shanjer, M., Mbuagbaw, L. C. E., Delluc, A., Crowther, M. A., & Siegal, D. M. (2021) · Journal of Thrombosis and Haemostasis · doi:10.1111/jth.15453 · Cited by 46
Reumkens, A., van der Zander, Q. E. W., Winkens, B., Bogie, R. M. M., Bakker, C. M., Sanduleanu, S., & Masclee, A. (2022) · Digestive Endoscopy · doi:10.1111/den.14237 · Cited by 50
Quinzi, V., Polizzi, A., Ronsivalle, V., Santonocito, S., Conforte, C., Manenti, R. J., Isola, G., & Giudice, A. L. (2022) · Children · doi:10.3390/children9091390 · Cited by 42
Ultrasound for the diagnosis of necrotizing fasciitis: A systematic review of the literature
Marks, A., Patel, D., Sundaram, T., Johnson, J., & Gottlieb, M. A. (2022) · The American Journal of Emergency Medicine · doi:10.1016/j.ajem.2022.12.037 · Cited by 44
Ashraf, G., McGuinness, M. B., Khan, M. A., Obtinalla, C., Hadoux, X., & van Wijngaarden, P. (2023) · Alzheimer s & Dementia Diagnosis Assessment & Disease Monitoring · doi:10.1002/dad2.12421 · Cited by 63
Messina, A., Caporale, M., Calabrò, L. A., Lionetti, G., Bono, D., Matronola, G. M., Brunati, A., Frassanito, L., Morenghi, E., Antonelli, M. M., et al. (2023) · Critical Care · doi:10.1186/s13054-023-04706-0 · Cited by 42
Lam, C., Wong, Y. L., Tang, Z., Hu, X., Nguyen, T. X., Yang, D., Zhang, S., Ding, J., Szeto, S., Ran, A. R., et al. (2024) · Diabetes Care · doi:10.2337/dc23-0993 · Cited by 49
Instrumental assessment of sleep bruxism: A systematic review and meta-analysis
Cid-Verdejo, R., Farías, C. C., Martínez‐Pozas, O., Oliva, E. M., Cuenca‐Zaldívar, J. N., García, I. A., Orozco, F. J. M., & Romero, E. A. S. (2024) · Sleep Medicine Reviews · doi:10.1016/j.smrv.2024.101906 · Cited by 52
van Leeuwen, L. M., Fourie, E., van den Brink, G., Bekker, V., & van Houten, M. A. (2024) · Clinical Microbiology and Infection · doi:10.1016/j.cmi.2024.03.005 · Cited by 46
Wu, W., Francis, H., Lucien, A., Wheeler, T.-A., & Gandy, M. (2024) · Neuropsychology Review · doi:10.1007/s11065-024-09640-8 · Cited by 48
“The QUADAS has been recommended by the Cochrane Collaboration (Whiting et al., 2011), and was modified by Broen and colleagues (2012) according to criteria developed by Leboeuf-Yde and Lauritsen (1995) and Walker and colleagues (2000) to increase applicability for prevalence studies.”
The effect of prenatal maternal distress on offspring brain development: A systematic review
Mandl, S., Alexopoulos, J., Doering, S., Wildner, B., Seidl, R., & Bartha, L. (2024) · Early Human Development · doi:10.1016/j.earlhumdev.2024.106009 · Cited by 48
Systematic Review of Newborn Screening Programmes for Spinal Muscular Atrophy
Cooper, K. L., Nalbant, G., Sutton, A., Harnan, S., Thokala, P., Chilcott, J. B., McNeill, A., & Bessey, A. (2024) · International Journal of Neonatal Screening · doi:10.3390/ijns10030049 · Cited by 43
Mubonanyikuzo, V., Yan, H., Komolafe, T. E., Zhou, L., Wu, T., & Wang, N. (2024) · Journal of Medical Internet Research · doi:10.2196/62647 · Cited by 47
“The quality assessment of the included studies was conducted using the Quality Assessment of Diagnostic Accuracy Studies-2 tool [21], a validated instrument designed to rigorously evaluate both the methodological integrity and reporting quality of diagnostic accuracy studies.”
Abdalla, G. M., Matuk, R. F., Venugopal, V., Verde, F., Magnuson, T. H., Schweitzer, M., & Steele, K. E. (2015) · Clinical Radiology · doi:10.1016/j.crad.2015.04.007 · Cited by 46
Systematic Review into Diagnostics for Post-Kala-Azar Dermal Leishmaniasis (PKDL)
Adams, E. R., Versteeg, I. A. J., & Leeflang, M. (2013) · Journal of Tropical Medicine · doi:10.1155/2013/150746 · Cited by 42
Self-citationMeta‐analysis: IL ‐28 B genotype and sustained viral clearance in HCV genotype 1 patients
Rangnekar, A. S., & Fontana, R. J. (2012) · Alimentary Pharmacology & Therapeutics · doi:10.1111/j.1365-2036.2012.05145.x · Cited by 43
Schroeder, L. F., Robilotti, E. V., Peterson, L. R., Banaei, N., & Dowdy, D. W. (2013) · Journal of Clinical Microbiology · doi:10.1128/jcm.02777-13 · Cited by 42
Glucose prediction by analysis of exhaled metabolites – a systematic review
Leopold, J. H., van Hooijdonk, R. T. M., Sterk, P. J., Abu–Hanna, A., Schultz, M. J., & Bos, L. D. J. (2014) · BMC Anesthesiology · doi:10.1186/1471-2253-14-46 · Cited by 46
Evaluating Diagnostic Accuracy in the Face of Multiple Reference Standards
Naaktgeboren, C. A., de Groot, J. A. H., van Smeden, M., Moons, K. G. M., & Reitsma, J. B. (2013) · Annals of Internal Medicine · doi:10.7326/0003-4819-159-3-201308060-00009 · Cited by 43
Self-citationLee, C.-H., Kim, H.-W., Kim, H. R., Lee, C.-Y., Kim, J.-H., & Sala, F. (2014) · Clinical Neurophysiology · doi:10.1016/j.clinph.2014.11.026 · Cited by 42
Coelen, R. J. S., Ruys, A. T., Besselink, M. G., Busch, O. R., & van Gulik, T. M. (2016) · Surgical Endoscopy · doi:10.1007/s00464-016-4788-y · Cited by 42
Multiparametric Magnetic Resonance Imaging in the Diagnosis of Prostate Cancer: A Systematic Review
Haider, M., Yao, X., Loblaw, A., & Finelli, A. (2016) · Clinical Oncology · doi:10.1016/j.clon.2016.05.003 · Cited by 42
Diagnostic performance of serum IgG4 level for IgG4-related disease: a meta-analysis
Xu, W., Ling, Y.-C., Wang, Z.-K., & Deng, F. (2016) · Scientific Reports · doi:10.1038/srep32035 · Cited by 42
Gong, Y., Wang, Q., Li, D., Jia, Y., Hua, C., Mi, F., & Li, C. (2016) · Oncotarget · doi:10.18632/oncotarget.12959 · Cited by 47
Barelds, I., Krijnen, W. P., van de Leur, J. P., van der Schans, C. P., & Goddard, R. J. (2017) · Journal of Emergency Medicine · doi:10.1016/j.jemermed.2017.04.035 · Cited by 48
Diao, K., Yang, Z., Ma, M., He, Y., Zhao, Q., Liu, X., Gao, Y., Xie, L., & Guo, Y. (2017) · Scientific Reports · doi:10.1038/s41598-017-09096-2 · Cited by 46
Posso, M., Puig, T., Carles-Lavila, M., Rué, M., Canelo‐Aybar, C., & Bonfill, X. (2017) · European Journal of Radiology · doi:10.1016/j.ejrad.2017.09.013 · Cited by 47
Meng, Q., Shi, S., Liang, C., Xiang, J., Liang, D., Zhang, B., Qin, Y., Ji, S., Xu, W., Xu, J., et al. (2017) · Journal of Cancer · doi:10.7150/jca.18901 · Cited by 45
“The studies could be considered to be of high quality if they enrolled all consecutive, or a random sample of, eligible patients, an index test was always conducted and interpreted prior to the reference standard, and all participants underwent the same reference standard testing method [27].”
Kiaos, A., Tziatzios, I., Hadjimiltiades, S., Karvounis, C., & Karamitsos, T. D. (2017) · International Journal of Cardiology · doi:10.1016/j.ijcard.2017.11.066 · Cited by 45
Yu, J., Zheng, J., Xu, W., Weng, J., Gao, L., Li, T., Liang, F., & Zhang, J. (2018) · World Neurosurgery · doi:10.1016/j.wneu.2018.03.179 · Cited by 45
Zhang, X., & Xiao, C. (2018) · Cellular Physiology and Biochemistry · doi:10.1159/000489443 · Cited by 43
Vos, S., van Diest, P. J., & Moelans, C. B. (2018) · Critical Reviews in Oncology/Hematology · doi:10.1016/j.critrevonc.2018.05.008 · Cited by 45
Signori, C., Gimenez, T., Mendes, F. M., Huysmans, M. C. D. N. J. M., Opdam, N. J. M., & Cenci, M. S. (2018) · Journal of Dentistry · doi:10.1016/j.jdent.2018.05.018 · Cited by 46
Vandenberg, J. T., Cullison, K., Fowler, S. A., Parsons, M. S., McAndrew, C. M., & Carpenter, C. R. (2018) · Journal of Emergency Medicine · doi:10.1016/j.jemermed.2018.10.032 · Cited by 42
Duan, H., Xia, L., He, W., Lin, Y., Zhi-hui, L., & Lan, Q. (2019) · International Journal of Pediatric Otorhinolaryngology · doi:10.1016/j.ijporl.2019.01.011 · Cited by 48
Liu, R., Su, X., Long, Y., Zhou, D., Zhang, X., Ye, Z., Ma, J., Tang, T., Wang, F., & He, C. (2019) · Mutation Research/Reviews in Mutation Research · doi:10.1016/j.mrrev.2019.01.003 · Cited by 45
Dessureault-Dober, I., Bronchti, G., & Bussières, A. (2018) · Journal of Manipulative and Physiological Therapeutics · doi:10.1016/j.jmpt.2018.02.007 · Cited by 44
Lemeunier, N., da Silva-Oolup, S., Olesen, K., Shearer, H. M., Carroll, L., Brady, O., Côté, E., Stern, P. J., Tuff, T., Suri-Chilana, M., et al. (2019) · European Spine Journal · doi:10.1007/s00586-019-05949-8 · Cited by 42
Bach, S., Sluiter, N. R., Beagan, J. J., Mekke, J. M., Ket, J. C. F., van Grieken, N. C. T., Steenbergen, R. D. M., Ylstra, B., Kazemier, G., & Tuynman, J. B. (2019) · JNCI Cancer Spectrum · doi:10.1093/jncics/pkz042 · Cited by 46
Harding, Z., Wilkinson, T., Stevenson, A. J., Horrocks, S., Ly, A., Schnier, C., Breen, D. P., Rannikmäe, K., Sudlow, C. L. M., & on behalf of Dementias Platform, U. K. (2019) · PLoS ONE · doi:10.1371/journal.pone.0198736 · Cited by 45
Lupu, M., Popa, I. M., Voiculescu, V. M., Căruntu, A., & Căruntu, C. (2019) · Journal of Clinical Medicine · doi:10.3390/jcm8091462 · Cited by 45
Cohen, J. F., Ouziel, A., Matczak, S., Brice, J., Spijker, R., Lortholary, O., Bougnoux, M., & Toubiana, J. (2019) · Clinical Microbiology and Infection · doi:10.1016/j.cmi.2019.09.010 · Cited by 44
Zheng, W., Zhan, J., Chen, A., Ma, H., Yang, H.-J., & Maharjan, R. (2019) · Medicine · doi:10.1097/md.0000000000018496 · Cited by 55
“Quality assessment included in the study was based on the QUADAS-2 scale.([21]) Two reviewers independently evaluated the quality of the literature, in case of conflict, a third reviewer was consulted, and disagreement was settled through multilateral discussion.”
Zhang, L., Wu, H., Zhao, M., & Lu, Q. (2020) · Autoimmunity · doi:10.1080/08916934.2019.1710135 · Cited by 42
Kraaijpoel, N., Carrier, M., Gal, G. L., McInnes, M. D. F., Salameh, J., McGrath, T. A., van Es, N., Moher, D., Buller, H. R., Bossuyt, P. M., et al. (2020) · PLoS ONE · doi:10.1371/journal.pone.0228788 · Cited by 50
Self-citationGupta, P., Bansal, V., Kumar, P. M., Sinha, S. K., Samanta, J., Mandavdhare, H. S., Sharma, V., Dutta, U., & Kochhar, R. K. (2020) · British Journal of Radiology · doi:10.1259/bjr.20190847 · Cited by 44
Kim, J. Y., Suh, Y. J., Han, K., Kim, Y. J., & Choi, B. W. (2020) · Korean Journal of Radiology · doi:10.3348/kjr.2019.0499 · Cited by 46
Diabetes Mellitus Increases Risk of Incident Dementia in APOE ɛ 4 Carriers: A Meta-Analysis
Li, L., Cavuoto, M. G., Biddiscombe, K. J., & Pike, K. E. (2020) · Journal of Alzheimer s Disease · doi:10.3233/jad-191068 · Cited by 46
“The methodological quality of each study was assessed using the Quality Assessment of Diagnostic Accuracy Studies – Revised (QUADAS-2) tool’s four domains [43]: patient selection; index test(s); reference standard; flow and timing, with modifica-tions specific to the content of the current review.”
Yao, X., Flórez, I. D., Zhang, P., Zhang, C., Zhang, Y., Wang, C., Liu, X., Nie, X., Wei, B., & Ghert, M. A. (2020) · Journal of Evidence-Based Medicine · doi:10.1111/jebm.12384 · Cited by 47
Luo, W., Lin, Y., Li, Z., Wang, W., & Shi, Y. (2020) · BMC Pulmonary Medicine · doi:10.1186/s12890-020-01192-w · Cited by 42
Incidental pulmonary embolism in oncologic patients—a systematic review and meta-analysis
Meyer, H., Wienke, A., & Surov, A. (2020) · Supportive Care in Cancer · doi:10.1007/s00520-020-05601-y · Cited by 46
White, S., Schmidt, R. L., Walker, B. S., & Hanson, K. E. (2020) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd009833.pub2 · Cited by 72
Huang, X., Yang, J., Li, J., & Xiong, Y. (2020) · Medicine · doi:10.1097/md.0000000000020932 · Cited by 48
Adam, J. A., van Diepen, P. R., Mom, C. H., Stoker, J., van Eck‐Smit, B. L. F., & Bipat, S. (2020) · Gynecologic Oncology · doi:10.1016/j.ygyno.2020.08.021 · Cited by 44
Dabbagh, A., MacDermid, J. C., Yong, J., Macedo, L. G., & Packham, T. (2020) · Journal of Orthopaedic and Sports Physical Therapy · doi:10.2519/jospt.2020.9599 · Cited by 50
Yu, G., Shen, Y., Ye, B., & Shi, Y. (2021) · PLoS ONE · doi:10.1371/journal.pone.0253658 · Cited by 46
A brief introduction of meta‐analyses in clinical practice and research
Wang, X., Zhang, X., Li, Z., Zhong, W., Yang, P., & Mao, C. (2021) · The Journal of Gene Medicine · doi:10.1002/jgm.3312 · Cited by 45
Boyle, R. S. J., & Body, R. M. (2021) · Annals of Emergency Medicine · doi:10.1016/j.annemergmed.2020.10.020 · Cited by 47
Silent existence of eosinopenia in sepsis: a systematic review and meta-analysis
Lin, Y., Rong, J., & Zhang, Z. (2021) · BMC Infectious Diseases · doi:10.1186/s12879-021-06150-3 · Cited by 42
Rees, C. O., Nederend, J., Mischi, M., van Vliet, H. A. A. M., & Schoot, B. C. (2021) · Acta Obstetricia Et Gynecologica Scandinavica · doi:10.1111/aogs.14139 · Cited by 51
Maniaci, A., Merlino, F., Cocuzza, S. G., Iannella, G., Vicini, C., Cammaroto, G., Lechien, J. R., Calvo‐Henríquez, C., & Mantia, I. L. (2021) · European Archives of Oto-Rhino-Laryngology · doi:10.1007/s00405-021-06724-6 · Cited by 43
Xie, Y., Huang, P., Zhang, J., Tian, R., Jin, W., Xie, H., Du, J., Zhou, Z., & Wang, R. (2021) · Annals of Palliative Medicine · doi:10.21037/apm-20-1855 · Cited by 42
Ye, P., Cai, P., Xie, J., & Wei, Y. (2021) · PLoS ONE · doi:10.1371/journal.pone.0248775 · Cited by 47
Lindner, N., Kuwabara, A., & Holt, T. (2021) · Systematic Reviews · doi:10.1186/s13643-021-01644-2 · Cited by 47
Carlton, H. C., Savović, J., Dawson, S., Mitchelmore, P. J., & Elwenspoek, M. M. C. (2021) · Clinical Microbiology and Infection · doi:10.1016/j.cmi.2021.05.018 · Cited by 45
Systematic review and meta-analysis of diagnostic methods for occlusal surface caries
Kapor, S., Ranković, M. J., Khazaei, Y., Crispin, A., Schüler, I. M., Krause, F., Lussi, A., Neuhaus, K. W., Eggmann, F., Michou, S., et al. (2021) · Clinical Oral Investigations · doi:10.1007/s00784-021-04024-1 · Cited by 48
Detection and diagnosis of large airway collapse: a systematic review
Mitropoulos, A., Song, W., Almaghlouth, F., Kemp, S. V., Polkey, M. I., & Hull, J. H. (2021) · ERJ Open Research · doi:10.1183/23120541.00055-2021 · Cited by 43
“…items regarding external and internal validity from the assessment tools for population-based prevalence studies [15] and diagnostic studies [16], which included recruitment method, sample size justification, sample representativeness, risk of selection bias, appropriate exclusion criteria…”
Travaglino, A., Raffone, A., Santoro, A., Raimondo, D., Angelico, G., Valente, M., Arciuolo, D., Scaglione, G., D’Alessandris, N., Casadio, P., et al. (2021) · Gynecologic Oncology · doi:10.1016/j.ygyno.2021.07.007 · Cited by 49
Aung, N. M., & Myint, K. K. (2021) · International Journal of Dentistry · doi:10.1155/2021/1107471 · Cited by 42
Huang, G. C., Wei, X., Tang, H., Bai, F., Lin, X., & Xue, D. (2021) · Journal of Thoracic Disease · doi:10.21037/jtd-21-810 · Cited by 52
Chen, Y.-R., Liang, C., Chu, H., Voss, J. G., Kang, X. L., O’Connell, G. C., Jen, H., Liu, D., Hsiao, S. S., & Chou, K. (2021) · Ageing Research Reviews · doi:10.1016/j.arr.2021.101446 · Cited by 46
Chen, C., Qin, Y., Chen, H., Zhu, D., Gao, F., & Zhou, X. (2021) · Insights into Imaging · doi:10.1186/s13244-021-01034-1 · Cited by 46
Kawasaki, T., Nakagawa, N., Murata, M., Yasuo, S., Yoshida, T., Andō, K., Okamori, S., & Okada, Y. (2021) · Respiratory Investigation · doi:10.1016/j.resinv.2021.11.011 · Cited by 46
Baashar, Y. M., Alkawsi, G. A., Alhussian, H., Capretz, L. F., Alwadain, A. S., Alkahtani, A. A., & Almomani, M. A. (2022) · Computational Intelligence and Neuroscience · doi:10.1155/2022/5849995 · Cited by 52
Metadata
- Authors
- Whiting, P. F., Rutjes, A. W. S., Westwood, M. E., Mallett, S., Deeks, J. J., Reitsma, J. B., Leeflang, M. M. G., Sterne, J. A. C., Bossuyt, P. M. M., & the QUADAS-2 Group*
- Affiliations
- University of Bern (CH)
- Corresponding author
- Whiting, Penny F.
- ORCID
- Venue
- Annals of Internal Medicine
- Publisher
- American College of Physicians
- Published
- 2011-10-18
- Volume
- 155
- Issue
- 8
- Pages
- 529-536
- ISSN
- 0003-4819 (ISSN-L)
- 1539-3704
- OpenAlex
- W2107638293
- Semantic Scholar
- 8a5d0b5a9271ea14bcb8479bc32d3844a80655b9
- Cited by
- 14,199
- References
- 18
- Citations by year
- 2026: 1484 · 2025: 1569 · 2024: 1524 · 2023: 1305 · 2022: 1420 · 2021: 1514 · 2020: 1245 · 2019: 955 · 2018: 767 · 2017: 637 · 2016: 580 · 2015: 528 · 2014: 363 · 2013: 217 · 2012: 75
- FWCI
- 224.36
- Type
- journal article
- Language
- en
- Open access
- green
- hdl.handle.net
- Licence
- cc-by
- www.acpjournals.org/journal/aim/text-and-data-mining (tdm)
- Locations
- Annals of Internal Medicine (publishedVersion)
- PubMed (publishedVersion)
- Pure Amsterdam UMC (publishedVersion)
- Data Archiving and Networked Services (DANS) (submittedVersion)
- Florence Research (University of Florence) (submittedVersion)
- IRIS UNIMORE (University of Modena and Reggio Emilia) (submittedVersion, cc-by)
- University of Birmingham Research Portal (University of Birmingham) (submittedVersion)
- Bristol Research (University of Bristol) (submittedVersion)
- Funders
- Cancer Research UK
- Topics
- Social Sciences › Decision Sciences › Statistics, Probability and Uncertainty › Meta-analysis and systematic reviews
- Physical Sciences › Mathematics › Statistics and Probability › Statistical Methods in Epidemiology
- Health Sciences › Medicine › Public Health, Environmental and Occupational Health › Clinical practice guidelines implementation
- Keywords
- QUADAS-2, diagnostic accuracy studies, quality assessment, risk of bias, applicability, patient selection, index tests, reference materials, flowcharts, systematic reviews
- MeSH terms
- Diagnosis, Humans, Quality Control, Surveys and Questionnaires, Reference Standards, Review Literature as Topic, Time Factors, Bias, Patient Selection, Evidence-Based Medicine
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
A language model drew the claims from the paper on 2026-11-23, under version 3 of the claim definition (model deepseek-v4.1-flash, prompt extract-v3).
A second model labelled each claim on 2026-11-23 (model jev-1.13-20260917, definition revision gold-guideline-v0.2).
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.