QUADAS-2: A Revised Tool for the Quality Assessment of Diagnostic Accuracy Studies
Open accessThe DOI matches its Crossref record; 18 of the 18 references it cites were found in a registry or an index; none of the 21 sources its claims cite is checked for support yet.
Abstract
In 2003, the QUADAS tool for systematic reviews of diagnostic accuracy studies was developed. Experience, anecdotal reports, and feedback suggested areas for improvement; therefore, QUADAS-2 was developed. This tool comprises 4 domains: patient selection, index test, reference standard, and flow and timing. Each domain is assessed in terms of risk of bias, and the first 3 domains are also assessed in terms of concerns regarding applicability. Signalling questions are included to help judge risk of bias. The QUADAS-2 tool is applied in 4 phases: summarize the review question, tailor the tool and produce review-specific guidance, construct a flow diagram for the primary study, and judge bias and applicability. This tool will allow for more transparent rating of bias and applicability of primary diagnostic accuracy studies.
Overview
CoChat Summary
TL;DR
QUADAS-2 is a revised tool for assessing risk of bias and applicability in diagnostic accuracy studies, developed through a 4-stage evidence-based consensus process. It replaces the original QUADAS “yes/no/unclear” quality rating with domain-level judgments of low, high, or unclear risk of bias and concerns about applicability.
Key findings
- QUADAS-2 separates “quality” into risk of bias and concerns regarding applicability, defining quality as the degree to which diagnostic accuracy estimates avoided bias and the extent to which primary studies are applicable to the review question.
- The tool has 4 key domains—patient selection, index test, reference standard, and flow and timing—with the first 3 also assessed for applicability; it is completed in 4 phases and uses signaling questions to help judge risk of bias.
- Development drew on 4 reviews: 54 diagnostic accuracy reviews published between 2007 and 2009, structured feedback from 64 systematic reviewers who had used QUADAS, 101 studies on sources of bias and variation, and 8 studies evaluating QUADAS; a 1-day consensus meeting had 24 attendees, and piloting occurred in 5 reviews.
- Interrater reliability varied considerably, with better agreement on applicability than on risk of bias; all participants preferred QUADAS-2 to the original tool, but the authors could not currently include criteria for studies comparing multiple index tests because the evidence base was insufficient.
Methods
- Tool development followed Moher and colleagues’ 4-stage approach: define the scope, review the evidence base, hold a face-to-face consensus meeting, and refine through piloting.
- A steering group of 9 experts set the scope; the consensus meeting was held on 21 September 2010 in Birmingham, United Kingdom, with 24 attendees who split into groups of 4 to 6 participants; multiple rounds of piloting used online questionnaires and other feedback, including pairs of reviewers piloting QUADAS-2 in 5 reviews.
- No primary statistical analysis was reported; the work synthesized evidence reviews, consensus decisions, and pilot feedback to produce and refine the tool.
Limitations
- Stated: the authors decided they cannot currently include criteria for assessing studies that compare multiple index tests within QUADAS-2 because of the limited evidence base on risk of bias and sources of variation in such studies, and they plan future work on this topic.
- Stated: piloting showed poor interrater reliability and problems applying the domain on comparative accuracy studies; interrater reliability varied considerably overall, with better agreement on applicability than on risk of bias.
- Evident from the text: full details of the 4 evidence reviews were to be published separately, and the main text reports no quantitative reliability estimates, referring instead to an Appendix Table.
Model-written summary. Check it against the paper before relying on it.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
0 Valid · 0 Not valid · 16 Not checked · 24 Own results and interpretations
In the paper
“In a review on anti-cyclic citrullinated peptide antibodies for diagnosing rheumatoid arthritis (10), we found that some studies enrolled consecutive participants with confirmed diagnoses. In these studies, testing for anticyclic citrullinated peptide antibody showed greater sensitivity than in studies that included patients with suspected disease but an unconfirmed diagnosis (that is, difficult-t”
§ QUADAS-2: A Revised Tool for the Quality Assessment of Diagnostic Accuracy Studies > Signaling question 2: Was a case-control design avoided? Signaling question 3: Did the study avoid inappropriate exclusions?
What the sources say
- Not matchedcites [10]
The reference list we hold has no entry [10].
plainstates an association- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Not matched
A statement the paper makes itself — it cites no source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“Studies that make inappropriate exclusions (for example, not including”
§ QUADAS-2: A Revised Tool for the Quality Assessment of Diagnostic Accuracy Studies > Signaling question 2: Was a case-control design avoided? Signaling question 3: Did the study avoid inappropriate exclusions?
hedgedstates a possible cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
None of the sources cited for this claim could be matched to a paper, so there is nothing to check it against.
In the paper
“Because the accuracy of a test may depend on where it will be used in the diagnostic pathway, review authors are asked to describe patients in terms of setting, intended use of the index test, patient presentation, and previous testing (8,9).”
§ QUADAS-2: A Revised Tool for the Quality Assessment of Diagnostic Accuracy Studies > Phase 1: Review Question
What the sources say
- Not matchedcites [8]
The reference list we hold has no entry [8].
- Not matchedcites [9]
The reference list we hold has no entry [9].
hedgedstates a possible cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Not matched
In the paper
“Development of QUADAS-2 was based on the 4-stage approach proposed by Moher and colleagues (4): define the scope, review the evidence base, hold a face-to-face consensus meeting, and refine the tool through piloting.”
§ QUADAS-2: A Revised Tool for the Quality Assessment of Diagnostic Accuracy Studies > METHODS
What the sources say
- Not matchedcites [4]
The reference list we hold has no entry [4].
plainstates a cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: unclear — It is unclear whether the paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Not matched
None of the sources cited for this claim could be matched to a paper, so there is nothing to check it against.
In the paper
“Studies enrolling participants with known disease and a control group without the condition may similarly exaggerate diagnostic accuracy (7,11).”
§ QUADAS-2: A Revised Tool for the Quality Assessment of Diagnostic Accuracy Studies > Signaling question 2: Was a case-control design avoided? Signaling question 3: Did the study avoid inappropriate exclusions?
What the sources say
- Not matchedcites [7]
The reference list we hold has no entry [7].
- Not matchedcites [11]
The reference list we hold has no entry [11].
hedgedstates a possible cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Not matched
10 more claims
Create a free account to see all 40 claims and every source verdict.
- Probably not a substantial claim. 19
- It may state two separate claims as one. 16
- The quote only partly states this claim. 2
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“We assessed the study-level risk of bias with the QUADAS-2 tool”
In the citing paper
“We developed a revised risk-of-bias assessment tool to address these issues, incorporate advances in assessment of risk of bias used in other recently developed tools, 9 10 and integrate recent developments in estimation of intervention effects from randomised trials. 11”
From RoB 2: a revised tool for assessing risk of bias in randomised trials (2019) · cites this paper as [10]
In the citing paper
“Two reviewers independently assessed the quality of the included studies with the Quality Assessment of Diagnostic Accuracy Studies (Quadas-2) [33].”
From High-standard predictive equations for estimating body composition using bioelectrical impedance analysis: a systematic review (2024) · cites this paper as [33]
In the citing paper
“The quality of the selected studies was rigorously assessed using the Checklist for Artificial Intelligence in Medical Imaging (CLAIM) alongside the Quality Assessment of Diagnostic Accuracy Studies-2 (QUADAS-2).23,24”
From Artificial Intelligence Detection and Segmentation Models: A Systematic Review and Meta-Analysis of Brain Tumors in Magnetic Resonance Imaging (2024) · cites this paper as [24]
In the citing paper
“The methodological quality of each selected study was assessed according to the Quality Assessment of Diagnostic Accuracy Studies (QUADAS-2) checklist [15]”
From The diagnostic accuracy of digital, infrared and mercury-in-glass thermometers in measuring body temperature: a systematic review and network meta-analysis (2021) · cites this paper as [15]
20 more claims about this paper
Create a free account to see every claim other papers make about this one.
Citations
Cites
The Cochrane Collaboration's tool for assessing risk of bias in randomised trials
Higgins, J. P. T., Altman, D. G., Gotzsche, P. C., Juni, P., Moher, D., Oxman, A. D., Savovic, J., Schulz, K. F., Weeks, L., Sterne, J. A. C., et al. (2011) · BMJ · doi:10.1136/bmj.d5928 · Cited by 33,817
Self-citationWhiting, P., Rutjes, A. W., Reitsma, J. B., Bossuyt, P. M., & Kleijnen, J. (2003) · BMC Medical Research Methodology · doi:10.1186/1471-2288-3-25 · Cited by 3,592
Self-citationThe Hazards of Scoring the Quality of Clinical Trials for Meta-analysis
Jüni, P. (1999) · JAMA · doi:10.1001/jama.282.11.1054 · Cited by 1,981
Empirical evidence of design-related bias in studies of diagnostic tests.
Lijmer, J. G. (1999) · JAMA · doi:10.1001/jama.282.11.1061 · Cited by 1,861 · cited 2×
“Studies enrolling participants with known disease and a control group without the condition may similarly exaggerate diagnostic accuracy (7, 11).”
BackgroundGuidance for Developers of Health Research Reporting Guidelines
Moher, D., Schulz, K. F., Simera, I., & Altman, D. G. (2010) · PLoS Medicine · doi:10.1371/journal.pmed.1000217 · Cited by 1,437
Systematic Reviews of Diagnostic Test Accuracy
Leeflang, M. M. G., Deeks, J. J., Gatsonis, C., & Bossuyt, P. M. M. (2008) · Annals of Internal Medicine · doi:10.7326/0003-4819-149-12-200812160-00008 · Cited by 1,124
Self-citationSources of Variation and Bias in Studies of Diagnostic Accuracy: A Systematic Review
Whiting, P., Rutjes, A. W. S., Reitsma, J. B., Glas, A. S., Bossuyt, P. M. M., & Kleijnen, J. (2004) · Annals of Internal Medicine · doi:10.7326/0003-4819-140-3-200402030-00010 · Cited by 798 · cited 4×
“The third review was an update on sources of bias and variation in diagnostic accuracy studies that included 101 studies (7).”
BackgroundInfluentialSelf-citationEvaluation of QUADAS, a tool for the quality assessment of diagnostic accuracy studies
Whiting, P. F., Weswood, M. E., Rutjes, A. W., Reitsma, J. B., Bossuyt, P. N., & Kleijnen, J. (2006) · BMC Medical Research Methodology · doi:10.1186/1471-2288-6-9 · Cited by 769
Self-citationLeeflang, M. M. G., Moons, K. G. M., Reitsma, J. B., & Zwinderman, A. H. (2008) · Clinical Chemistry · doi:10.1373/clinchem.2007.096032 · Cited by 346 · cited 1×
“Test performance is likely to be poorer in an independent sample of patients in whom the same threshold is used (12).”
BackgroundSelf-citationNo role for quality scores in systematic reviews of diagnostic accuracy studies
Whiting, P., Harbord, R., & Kleijnen, J. (2005) · BMC Medical Research Methodology · doi:10.1186/1471-2288-5-19 · Cited by 337
Self-citation
Cited by
Items 701–800 of 14,770
Maggi, M., Panebianco, V., Mosca, A., Salciccia, S., Gentilucci, A., Pierro, G. D., Busetto, G. M., Barchetti, G., Campa, R., Sperduti, I., et al. (2019) · European Urology Focus · doi:10.1016/j.euf.2019.06.014 · Cited by 154
Boucheron, P., Lu, Y., Yoshida, K., Zhao, T., Funk, A. L., Lunel, F., Guingané, A. N., Tuaillon, É., van Holten, J., Chou, R., et al. (2020) · The Lancet Infectious Diseases · doi:10.1016/s1473-3099(20)30593-4 · Cited by 159
Bass, E. J., Pantović, A., Connor, M. J., Gabe, R., Padhani, A. R., Rockall, A., Sokhi, H. K., Tam, H., Winkler, M. H., & Ahmed, H. U. (2020) · Prostate Cancer and Prostatic Diseases · doi:10.1038/s41391-020-00298-w · Cited by 162
Lantos, P. M., Rumbaugh, J., Bockenstedt, L. K., Falck-Ytter, Y. T., Aguero-Rosenfeld, M. E., Auwaerter, P. G., Baldwin, K., Bannuru, R. R., Belani, K. K., Bowie, W. R., et al. (2021) · PubMed · doi:10.1093/cid/ciab049 · Cited by 149
Quinn, T. J., Richard, E., Teuschl, Y., Gattringer, T., Hafdi, M., O'Brien, J. T., Merriman, N. A., Gillebert, C. R., Huygelier, H., Verdelho, A., et al. (2021) · European Stroke Journal · doi:10.1177/23969873211042192 · Cited by 167
Smartphone applications for triaging adults with skin lesions that are suspicious for melanoma
Chuchu, N., Takwoingi, Y., Dinnes, J., Matin, R. N., Bassett, O., Moreau, J. F., Bayliss, S. E., Davenport, C., Godfrey, K., O'Connell, S., et al. (2018) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd013192 · Cited by 144
Self-citationRiggioni, C., Ricci, C., Moya, B., Wong, D., van Goor, E., Bartha, I., Buyuktiryaki, B., Giovannini, M., Jayasinghe, S., Jaumdally, H., et al. (2024) · Allergy · doi:10.1111/all.15939 · Cited by 144
“The data were synthetized by tabulating the index test's true positives, true negatives, false positives and false negatives.”
Yousefifard, M., Baikpour, M., Ghelichkhani, P., Asady, H., Nia, K. S., Jafari, A. M., Hosseini, M., & Safari, S. (2016) · Archives of Academic Emergency Medicine · doi:10.22037/aaem.v4i1.208 · Cited by 187
Chellapandian, D., Lehrnbecher, T., Phillips, B., Fisher, B. T., Zaoutis, T. E., Steinbach, W. J., Beyene, J., & Sung, L. (2015) · Journal of Clinical Oncology · doi:10.1200/jco.2014.58.0480 · Cited by 150
Goto, M., Ohl, M., Schweizer, M. L., & Perencevich, E. N. (2013) · Clinical Infectious Diseases · doi:10.1093/cid/cit737 · Cited by 155
Katsanos, A. H., Ψαλτοπούλου, Θ., Sergentanis, T. Ν., Frogoudaki, A., Vrettou, A., Ikonomidis, I., PARASKEVAIDIS, I. A., Parissis, J., Bogiatzi, C., Zompola, C., et al. (2016) · Annals of Neurology · doi:10.1002/ana.24609 · Cited by 159
Issa, Y., Kempeneers, M. A., van Santvoort, H. C., Bollen, T. L., Bipat, S., & Boermeester, M. A. (2017) · European Radiology · doi:10.1007/s00330-016-4720-9 · Cited by 154
“The methodological quality of the included articles was assessed by the Quality Assessment of Diagnostic Accuracy Studies version 2 (QUADAS-2) tool [7].”
MethodValue of physical tests in diagnosing cervical radiculopathy: a systematic review
Thoomes, E. J., van Geest, S., van der Windt, D., Falla, D., Verhagen, A. P., Koes, B. W., Graaf, M. T.-D., Kuijper, B., Scholten-Peeters, G. G. M., & Vleggeert-Lankamp, C. L. A. (2017) · The Spine Journal · doi:10.1016/j.spinee.2017.08.241 · Cited by 171
McGrath, T. A., Alabousi, M., Skidmore, B., Korevaar, D. A., Bossuyt, P. M. M., Moher, D., Thombs, B., & McInnes, M. D. F. (2017) · Systematic Reviews · doi:10.1186/s13643-017-0590-8 · Cited by 142
Self-citationKelly, H. A., Benavente, Y., Pavón, M. Á., de Sanjosé, S., Mayaud, P., & Lorincz, A. T. (2019) · British Journal of Cancer · doi:10.1038/s41416-019-0593-4 · Cited by 157
Suh, C. H., & Park, S. H. (2016) · Korean Journal of Radiology · doi:10.3348/kjr.2016.17.1.5 · Cited by 147
Farrington, K., Covic, A. C., Aucella, F., Clyne, N., de Vos, L., Findlay, A., Fouque, D. P., Grodzicki, T. K., Iyasere, O. U., Jager, K. J., et al. (2016) · Nephrology Dialysis Transplantation · doi:10.1093/ndt/gfw356 · Cited by 175
Rebolj, M., Assi, V., Brentnall, A. R., Parmar, D., & Duffy, S. W. (2018) · British Journal of Cancer · doi:10.1038/s41416-018-0080-3 · Cited by 160
Gottlieb, M. A., Holladay, D., & Peksa, G. D. (2018) · Annals of Emergency Medicine · doi:10.1016/j.annemergmed.2018.06.024 · Cited by 152
Gil, M. M., Galeva, S., Jani, J. C., Konstantinidou, L., Akolekar, R., Plana, N., & Nicolaides, K. H. (2019) · Ultrasound in Obstetrics and Gynecology · doi:10.1002/uog.20284 · Cited by 157
Affolter, K. E., Schmidt, R. L., Matynia, A. P., Adler, D. G., & Factor, R. E. (2012) · Digestive Diseases and Sciences · doi:10.1007/s10620-012-2439-2 · Cited by 151
Zwaans, W. A. R., Mallia, P., van Winden, M. E. C., & Rohde, G. G. U. (2014) · Journal of Clinical Virology · doi:10.1016/j.jcv.2014.06.025 · Cited by 159
“These criteria, based on the revised Quality Assessment of Diagnostic Accuracy Studies (QUADAS2-)tool [16] , were used to assess the risk of bias at the study level by judgment of an adequate or inadequate method.”
Riches, N., Panagioti, M., Alam, R., Cheraghi-Sohi, S., Campbell, S., Esmail, A., & Bower, P. (2016) · PLOS ONE · doi:10.1371/journal.pone.0148991 · Cited by 139
Screening strategies for atrial fibrillation: a systematic review and cost-effectiveness analysis
Welton, N. J., McAleenan, A., Thom, H. H., Davies, P., Hollingworth, W., Higgins, J. P., Okoli, G., Sterne, J. A., Feder, G., Eaton, D., et al. (2017) · Health Technology Assessment · doi:10.3310/hta21290 · Cited by 141
Self-citationBohner, L. O. L., Gamba, D. D., Hanisch, M. R., Marció, B. S., Neto, P. T., Laganá, D. C., & Sesma, N. (2018) · Journal of Prosthetic Dentistry · doi:10.1016/j.prosdent.2018.01.015 · Cited by 166
“The risk of bias assessment was performed using the Quality Assessment Tool for Diagnostic Accuracy Studies-2 (QUADAS-2).(21) The tool comprised questions related to 4 domains: patient selection, index test, reference standard, and flow and timing.”
Wells, G. A., Shea, B., Higgins, J. P., Sterne, J., Tugwell, P., & Reeves, B. C. (2013) · Research Synthesis Methods · doi:10.1002/jrsm.1077 · Cited by 141
Self-citationStevenson, M., Pandor, A., James, M. M., Rafia, R., Uttley, L., Stevens, J., Sanderson, J., Wong, R., Perkins, G. D., McMullan, R., et al. (2016) · Health Technology Assessment · doi:10.3310/hta20460 · Cited by 155
Carsetti, A., Sorbello, M., Adrario, E., Donati, A., & Falcetta, S. (2022) · Anesthesia & Analgesia · doi:10.1213/ane.0000000000005839 · Cited by 169
Ajmera, V., Kim, B. K., Yang, K., Majzoub, A. M., Nayfeh, T., Tamaki, N., Izumi, N., Nakajima, A., Idilman, R., Gumussoy, M., et al. (2022) · Gastroenterology · doi:10.1053/j.gastro.2022.06.073 · Cited by 138
Watts, D., Pulice, R. F., Reilly, J. P., Brunoni, A. R., Kapczinski, F. P., & Passos, I. C. (2022) · Translational Psychiatry · doi:10.1038/s41398-022-02064-z · Cited by 155
Das, S. K., Choupoo, N. S., Haldar, R., & Lahkar, A. (2014) · Canadian Journal of Anesthesia/Journal canadien d anesthésie · doi:10.1007/s12630-014-0301-z · Cited by 157
van Mourik, M. S. M., van Duijn, P. J., Moons, K. G. M., Bonten, M. J. M., & Lee, G. M. (2015) · BMJ Open · doi:10.1136/bmjopen-2015-008424 · Cited by 156
Adams, H. J. A., Kwee, T. C., de Keizer, B., Fijnheer, R., de Klerk, J. M. H., Littooij, A. S., & Nievelstein, R. A. J. (2013) · Annals of Oncology · doi:10.1093/annonc/mdt533 · Cited by 149
Carpenter, C. R., Hussain, A. M., Ward, M. J., Zipfel, G. J., Fowler, S., Pines, J. M., & Sivilotti, M. L. A. (2016) · Academic Emergency Medicine · doi:10.1111/acem.12984 · Cited by 158
Bennani‐Baïti, B., & Baltzer, P. (2016) · Radiology · doi:10.1148/radiol.2016161106 · Cited by 147
Staub, L. J., Biscaro, R. R. M., Kaszubowski, E., & Maurici, R. (2018) · Injury · doi:10.1016/j.injury.2018.01.033 · Cited by 151
Song, J. W., Pavlou, A., Xiao, J., Kasner, S. E., Fan, Z., & Messe, S. R. (2020) · Stroke · doi:10.1161/strokeaha.120.031480 · Cited by 150
Clarke, M. A., Deshmukh, A. A., Suk, R., Roberts, J. M., Gilson, R. J. C., Jay, N., Stier, E. A., & Wentzensen, N. (2022) · International Journal of Cancer · doi:10.1002/ijc.34199 · Cited by 148
Trujillo-Gómez, J., Tsokani, S., Arango-Ferreira, C., Atehortúa-Muñoz, S., Jimenez-Villegas, M. J., Serrano-Tabares, C., Veroniki, A.-A., & Florez, I. D. (2022) · EClinicalMedicine · doi:10.1016/j.eclinm.2022.101275 · Cited by 139
Urinary Interleukin 18 for Detection of Acute Kidney Injury: A Meta-analysis
Liu, Y., Guo, W., Zhang, J., Xu, C., Yu, S., Mao, Z., Wu, J., Ye, C., Mei, C., & Dai, B. (2013) · American Journal of Kidney Diseases · doi:10.1053/j.ajkd.2013.05.014 · Cited by 153
“2013;62(6):1058-1067 revised QUADAS-2 criteria.(18) When a study reported multiple sensitivity or specificity values at different cutoffs, data with the highest Youden index (sensitivity specificity 1), rather than the highest sensitivity, were used for meta-analysis.”
BackgroundMercier, E., Boutin, A., Lauzier, F., Fergusson, D. A., Simard, J.-F., Zarychanski, R., Moore, L., McIntyre, L. A., Archambault, P., Lamontagne, F., et al. (2013) · BMJ · doi:10.1136/bmj.f1757 · Cited by 133
Validity of Self‐Reported Periodontal Disease: A Systematic Review and Meta‐Analysis
Abbood, H. M., Hinz, J., Cherukara, G., & Macfarlane, T. V. (2016) · Journal of Periodontology · doi:10.1902/jop.2016.160196 · Cited by 152
Stenneberg, M. S., Rood, M., de Bie, R. A., Schmitt, M. A., Cattrysse, E., & Scholten-Peeters, G. G. M. (2016) · Archives of Physical Medicine and Rehabilitation · doi:10.1016/j.apmr.2016.10.003 · Cited by 156
Chang, K. C., Wu, W., Han, D., & Özçakar, L. (2017) · Archives of Physical Medicine and Rehabilitation · doi:10.1016/j.apmr.2017.08.467 · Cited by 146
Arias‐Bujanda, N., Regueira‐Iglesias, A., Balsa‐Castro, C., Nibali, L., Donos, N., & Tomás, I. (2019) · Journal Of Clinical Periodontology · doi:10.1111/jcpe.13202 · Cited by 156
Xue, P., Wang, J., Qin, D., Yan, H., Qu, Y., Seery, S., Jiang, Y., & Qiao, Y. (2022) · npj Digital Medicine · doi:10.1038/s41746-022-00559-z · Cited by 158
RAPID REVIEW: AN EMERGING APPROACH TO EVIDENCE SYNTHESIS IN HEALTH TECHNOLOGY ASSESSMENT
Khangura, S., Polisena, J., Clifford, T. J., Farrah, K., & Kamel, C. (2014) · International Journal of Technology Assessment in Health Care · doi:10.1017/s0266462313000664 · Cited by 138
Abd-Alrazaq, A., AlSaad, R., Shuweihdi, F., Ahmed, A., Aziz, S., & Sheikh, J. (2023) · npj Digital Medicine · doi:10.1038/s41746-023-00828-5 · Cited by 138
“We modi fi ed a well-known risk of bias assessment tool (Quality Assessment of Studies of Diagnostic Accuracy-Revised (QUADAS-2)) 79 by removing some irrelevant criteria and adding other criteria from another relevant tool (the Prediction model Risk Of Bias ASsessment Tool (PROBAST)) 80 .”
Jiwatram-Negrón, T., & El‐Bassel, N. (2014) · AIDS and Behavior · doi:10.1007/s10461-014-0827-7 · Cited by 147
“Study Quality Using an adapted version of the QUADAS 2 Tool [64], each study was assessed for its sample representativeness/ generalizability, quality and clarity of the inclusion/exclusion criteria, sampling procedures, random assignment/ randomization procedures, data analytical approach, power analysis plan and pow…”
Systematic review of fall risk screening tools for older patients in acute hospitals
Matarese, M., Ivziku, D., Bartolozzi, F., Piredda, M., & Marinis, M. G. D. (2014) · Journal of Advanced Nursing · doi:10.1111/jan.12542 · Cited by 150
Easterbrook, P. (2016) · Journal of Hepatology · doi:10.1016/j.jhep.2016.08.002 · Cited by 152
Pontrelli, G., Crescenzo, F. D., Buzzetti, R., Jenkner, A., Balduzzi, S., Carducci, F. I. C., Amodio, D., Luca, M. D., Chiurchiù, S., Davies, E. H., et al. (2017) · BMC Infectious Diseases · doi:10.1186/s12879-017-2396-7 · Cited by 164
Point-of-care ultrasonography for diagnosing thoracoabdominal injuries in patients with blunt trauma
Stengel, D., Leisterer, J., Ferrada, P. A., Ekkernkamp, A., Mutze, S., & Hönning, A. (2018) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd012669.pub2 · Cited by 193
Bacchi, S., Franke, K. B., Wewegama, D., Needham, E., Patel, S., & Menon, D. K. (2018) · Journal of Clinical Neuroscience · doi:10.1016/j.jocn.2018.03.026 · Cited by 148
Prevalence of sarcopenia in patients with solid tumors: A meta‐analysis based on 81,814 patients
Surov, A., & Wienke, A. (2022) · Journal of Parenteral and Enteral Nutrition · doi:10.1002/jpen.2415 · Cited by 138
A meta-analysis of diagnostic accuracy of three screening tools for insomnia
Chiu, H., Chang, L., Hsieh, Y.-J., & Tsai, P. (2016) · Journal of Psychosomatic Research · doi:10.1016/j.jpsychores.2016.06.010 · Cited by 147
Henderson, J. T., Thompson, J. H., Burda, B. U., & Cantor, A. (2017) · JAMA · doi:10.1001/jama.2016.18315 · Cited by 130
Han, Y., Kim, H. J., Kong, K. A., Kim, S. J., Lee, S. H., Ryu, Y. J., Lee, J. H., Kim, Y., Shim, S. S., & Chang, J. H. (2018) · PLoS ONE · doi:10.1371/journal.pone.0191590 · Cited by 147
Maitra, S., Som, A., & Bhattacharjee, S. (2018) · Clinical Microbiology and Infection · doi:10.1016/j.cmi.2018.03.032 · Cited by 153
Psychometric Properties of the Internet Addiction Test: A Systematic Review and Meta-Analysis
Moon, S. J., Hwang, J. S., Kim, J. Y., Shin, A. L., Bae, S. M., & Kim, J. W. (2018) · Cyberpsychology, Behavior, and Social Networking · doi:10.1089/cyber.2018.0154 · Cited by 125
“23 Patient selection, index test, reference standard, and flow and timing (‘‘flow’’ is defined here as whether there is loss or mismatch while a group is undergoing index test and/or reference standard; ‘‘timing’’ as whether the times of undergoing the index test and reference standard match) are the…”
Bradley, S. H., Abraham, S., Callister, M. E. J., Grice, A., Hamilton, W. T., López, R. R., Shinkins, B., & Neal, R. D. (2019) · British Journal of General Practice · doi:10.3399/bjgp19x706853 · Cited by 154
Bhatt, M., Braun, C., Patel, P. M., Patel, P., Begum, H., Wiercioch, W., Varghese, J., Wooldridge, D., Alturkmani, H. J., Thomas, M. B., et al. (2020) · Blood Advances · doi:10.1182/bloodadvances.2019000960 · Cited by 161
rs-fMRI and machine learning for ASD diagnosis: a systematic review and meta-analysis
Santana, C. P., Carvalho, E., Rodrigues, I. D., Bastos, G. S., de Souza, A. D., & de Brito, L. L. (2022) · Scientific Reports · doi:10.1038/s41598-022-09821-6 · Cited by 150
Bharat, C., Webb, P., Wilkinson, Z., McKetin, R., Grebely, J., Farrell, M., Holland, A., Hickman, M., Tran, L. T., Clark, B., et al. (2023) · Addiction · doi:10.1111/add.16200 · Cited by 154
Hooft, J. V. ’., van der Lee, J. H., Opmeer, B. C., Aarnoudse-Moens, C. S. H., Leenders, A. G. E., Mol, B. W., & de Haan, T. R. (2015) · Systematic Reviews · doi:10.1186/s13643-015-0058-7 · Cited by 152
Stress Radiography for the Diagnosis of Knee Ligament Injuries: A Systematic Review
James, E. W., Williams, B. T., & LaPrade, R. F. (2014) · Clinical Orthopaedics and Related Research · doi:10.1007/s11999-014-3470-8 · Cited by 145
Accuracy of Peripheral Thermometers for Estimating Temperature
Niven, D. J., Laupland, K. B., & Stelfox, H. T. (2016) · Annals of Internal Medicine · doi:10.7326/l16-0069 · Cited by 135
Agrawal, S., Tapmeier, T. T., Rahmioglu, N., Kirtley, S., Zondervan, K. T., & Becker, C. M. (2018) · International Journal of Molecular Sciences · doi:10.3390/ijms19020599 · Cited by 128
Kay, A. W., Fernández, L. G., Takwoingi, Y., Eisenhut, M., Detjen, A., Steingart, K. R., & Mandalakas, A. M. (2020) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd013359.pub2 · Cited by 156
Zhang, Y., Huang, L., Wang, D., Ren, P., Qi, H. Y., & Kang, D. (2021) · Journal of Evidence-Based Medicine · doi:10.1111/jebm.12427 · Cited by 153
Bösch, P., Bond, M., Dejaco, C., Ponte, C., Mackie, S. L., Falzon, L., Schmidt, W., & Ramiro, S. (2023) · RMD Open · doi:10.1136/rmdopen-2023-003379 · Cited by 149
Piccaluga, P. P., Fuligni, F., De Leo, A., Bertuzzi, C., Rossi, M., Bacci, F., Sabattini, E., Agostinelli, C., Gazzola, A., Laginestra, M. A., et al. (2013) · Journal of Clinical Oncology · doi:10.1200/jco.2012.42.5611 · Cited by 134
Nwachuku, E. L., Balzer, J. R., Yabes, J. G., Habeych, M. E., Crammond, D. J., & Thirumala, P. D. (2014) · JAMA Neurology · doi:10.1001/jamaneurol.2014.3071 · Cited by 144
Korevaar, D. A., Crombag, L. M. M. J., Cohen, J. F., Spijker, R., Bossuyt, P. M., & Annema, J. T. (2016) · The Lancet Respiratory Medicine · doi:10.1016/s2213-2600(16)30317-4 · Cited by 150
Self-citationSerum amylase and lipase and urinary trypsinogen and amylase for diagnosis of acute pancreatitis
Rompianesi, G., Hann, A., Komolafe, O., Pereira, S. P., Davidson, B. R., & Gurusamy, K. S. (2017) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd012010.pub2 · Cited by 167
McHugh, T., Snidvongs, K., Xie, M., Banglawala, S. M., & Sommer, D. D. (2018) · International Forum of Allergy & Rhinology · doi:10.1002/alr.22194 · Cited by 144
Part 8: Education, implementation, and teams
Finn, J., Bhanji, F., Lockey, A. S., Monsieurs, K. G., Frengley, R., Iwami, T., Lang, E., Huei‐Ming, M., Mancini, M. E., McNeil, M. A., et al. (2015) · Resuscitation · doi:10.1016/j.resuscitation.2015.07.046 · Cited by 148
Xu, H.-L., Gong, T., Liu, F.-H., Chen, H.-Y., Xiao, Q., Hou, Y., Huang, Y., Sun, H., Shi, Y., Gao, S., et al. (2022) · EClinicalMedicine · doi:10.1016/j.eclinm.2022.101662 · Cited by 156
Selecting and implementing overview methods: implications from five exemplar overviews
Pollock, A., Campbell, P., Brunton, G., Hunt, H., & Estcourt, L. (2017) · Systematic Reviews · doi:10.1186/s13643-017-0534-3 · Cited by 134
Khan, F. A., Majidulla, A., Tavaziva, G., Nazish, A., Abidi, S. K., Benedetti, A., Menzies, D., Johnston, J. C., Khan, A. J., & Saeed, S. (2020) · The Lancet Digital Health · doi:10.1016/s2589-7500(20)30221-1 · Cited by 134
Tax, C., Rovers, M. M., de Graaf, C., Zusterzeel, P. L. M., & Bekkers, R. L. M. (2015) · Gynecologic Oncology · doi:10.1016/j.ygyno.2015.09.076 · Cited by 143
Review of methods used by chiropractors to determine the site for applying manipulation
Triano, J. J., Budgell, B., Bagnulo, A., Roffey, B., Bergmann, T. F., Cooperstein, R., Gleberzon, B. J., Good, C. J., Perron, J., & Tepe, R. E. (2013) · Chiropractic & Manual Therapies · doi:10.1186/2045-709x-21-36 · Cited by 148
Lam, K., van Asten, S. A. V., Nguyen, T., La Fontaine, J., & Lavery, L. A. (2016) · Clinical Infectious Diseases · doi:10.1093/cid/ciw445 · Cited by 132
Eng, K., Abadeh, A., Ligocki, C., Lee, Y. K., Moineddin, R., Adams-Webber, T., Schuh, S., & Doria, A. S. (2018) · Radiology · doi:10.1148/radiol.2018180318 · Cited by 158
Zhelev, Z., Walker, G. B., Henschke, N., Fridhandler, J. D., & Yip, S. (2019) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd011427.pub2 · Cited by 163
Jiang, Y., Xu, D., Song, H., Qiu, B., Tian, D., Li, Z., Ji, Y., & Wang, J. (2021) · BMJ Open · doi:10.1136/bmjopen-2020-048324 · Cited by 145
Machine Learning Prediction Models for Gestational Diabetes Mellitus: Meta-analysis
Zhang, Z., Yang, L., Han, W., Wu, Y., Zhang, L., Gao, C., Jiang, K., Liu, Y., & Wu, H. (2022) · Journal of Medical Internet Research · doi:10.2196/26634 · Cited by 150
Heng, S. C., Morrissey, O., Chen, S. C.-A., Thursky, K., Manser, R. L., Nation, R. L., Kong, D. C.-M., & Slavin, M. (2015) · Critical Reviews in Microbiology · doi:10.3109/1040841x.2013.804033 · Cited by 133
Thombs, B. D., Benedetti, A., Kloda, L. A., Levis, B., Nicolau, I., Cuijpers, P., Gilbody, S., Ioannidis, J. P. A., McMillan, D., Patten, S. B., et al. (2014) · Systematic Reviews · doi:10.1186/2046-4053-3-124 · Cited by 122
Fokom-Domgue, J., Combescure, C., Fokom-Defo, V., Tebeu, P. M., Vassilakos, P., Kengne, A. P., & Petignat, P. (2015) · BMJ · doi:10.1136/bmj.h3084 · Cited by 127
Reliability of Transcutaneous Bilirubin Devices in Preterm Infants: A Systematic Review
Nagar, G., Vandermeer, B., Campbell, S., & Kumar, M. (2013) · PEDIATRICS · doi:10.1542/peds.2013-1713 · Cited by 148
Thyroid nodules: diagnostic evaluation based on thyroid cancer risk assessment
Ospina, N. S., Iñiguez‐Ariza, N. M., & Castro, M. R. (2020) · BMJ · doi:10.1136/bmj.l6670 · Cited by 143
Stabile, A., Pellegrino, A. A., Mazzone, E., Cannoletta, D., de ANGELIS, M., Barletta, F. M., Scuderi, S., Cucchiara, V., Gandaglia, G., Raggi, D., et al. (2021) · European Urology Oncology · doi:10.1016/j.euo.2021.08.001 · Cited by 143
Meta-DiSc 2.0: a web application for meta-analysis of diagnostic test accuracy data
Plana, N., Arévalo-Rodríguez, I., Fernández-García, S., Soto, J., Fabregate, M., Pérez, T., Figuls, M. R. I., & Zamora, J. (2022) · BMC Medical Research Methodology · doi:10.1186/s12874-022-01788-2 · Cited by 141
Diagnostic and Prognostic Role of Cardiac Magnetic Resonance in MINOCA
Mileva, N. B., Paolisso, P., Gallinoro, E., Fabbricatore, D., Munhoz, D., Bergamaschi, L., Belmonte, M., Panayotov, P., Pizzi, C., Barbato, E., et al. (2023) · JACC. Cardiovascular imaging · doi:10.1016/j.jcmg.2022.12.029 · Cited by 149
Machine and Deep Learning for Tuberculosis Detection on Chest X-Rays: Systematic Literature Review
Hansun, S., Argha, A., Liaw, S., Celler, B. G., & Marks, G. B. (2023) · Journal of Medical Internet Research · doi:10.2196/43154 · Cited by 158
“To assess the risk of bias within the included studies, we used a modified Quality Assessment of Diagnostic Accuracy Studies version 2 (QUADAS-2) tool, which is recommended for evaluating the risk of bias and applicability of primary diagnostic accuracy studies in SLRs [31].”
Hill, S., Booth, R. A., Santaguida, P. L., Don-Wauchope, A., Brown, J. A., Oremus, M., Ali, U., Bustamam, A., Sohel, N., McKelvie, R. S., et al. (2014) · Heart Failure Reviews · doi:10.1007/s10741-014-9447-6 · Cited by 146
Tyrosine, Phenylalanine, and Tryptophan in Gastroesophageal Malignancy: A Systematic Review
Wiggins, T., Kumar, S., Markar, S. R., Antonowicz, S., & Hanna, G. B. (2015) · Cancer Epidemiology Biomarkers & Prevention · doi:10.1158/1055-9965.epi-14-0980 · Cited by 143
Detecting Secondary Caries Lesions: A Systematic Review and Meta-analysis
Brouwer, F., Askar, H., Paris, S., & Schwendicke, F. (2015) · Journal of Dental Research · doi:10.1177/0022034515611041 · Cited by 158
Quan, J., Pan, X., Zhao, L., Li, Z., Dai, K., Yan, F., Liu, S., Hongfei, M., & Lai, Y. (2018) · OncoTargets and Therapy · doi:10.2147/ott.s167853 · Cited by 138
Metadata
- Authors
- Whiting, P. F., Rutjes, A. W. S., Westwood, M. E., Mallett, S., Deeks, J. J., Reitsma, J. B., Leeflang, M. M. G., Sterne, J. A. C., Bossuyt, P. M. M., & the QUADAS-2 Group*
- Affiliations
- University of Bern (CH)
- Corresponding author
- Whiting, Penny F.
- ORCID
- Venue
- Annals of Internal Medicine
- Publisher
- American College of Physicians
- Published
- 2011-10-18
- Volume
- 155
- Issue
- 8
- Pages
- 529-536
- ISSN
- 0003-4819 (ISSN-L)
- 1539-3704
- OpenAlex
- W2107638293
- Semantic Scholar
- 8a5d0b5a9271ea14bcb8479bc32d3844a80655b9
- Cited by
- 14,199
- References
- 18
- Citations by year
- 2026: 1484 · 2025: 1569 · 2024: 1524 · 2023: 1305 · 2022: 1420 · 2021: 1514 · 2020: 1245 · 2019: 955 · 2018: 767 · 2017: 637 · 2016: 580 · 2015: 528 · 2014: 363 · 2013: 217 · 2012: 75
- FWCI
- 224.36
- Type
- journal article
- Language
- en
- Open access
- green
- hdl.handle.net
- Licence
- cc-by
- www.acpjournals.org/journal/aim/text-and-data-mining (tdm)
- Locations
- Annals of Internal Medicine (publishedVersion)
- PubMed (publishedVersion)
- Pure Amsterdam UMC (publishedVersion)
- Data Archiving and Networked Services (DANS) (submittedVersion)
- Florence Research (University of Florence) (submittedVersion)
- IRIS UNIMORE (University of Modena and Reggio Emilia) (submittedVersion, cc-by)
- University of Birmingham Research Portal (University of Birmingham) (submittedVersion)
- Bristol Research (University of Bristol) (submittedVersion)
- Funders
- Cancer Research UK
- Topics
- Social Sciences › Decision Sciences › Statistics, Probability and Uncertainty › Meta-analysis and systematic reviews
- Physical Sciences › Mathematics › Statistics and Probability › Statistical Methods in Epidemiology
- Health Sciences › Medicine › Public Health, Environmental and Occupational Health › Clinical practice guidelines implementation
- Keywords
- QUADAS-2, diagnostic accuracy studies, quality assessment, risk of bias, applicability, patient selection, index tests, reference materials, flowcharts, systematic reviews
- MeSH terms
- Diagnosis, Humans, Quality Control, Surveys and Questionnaires, Reference Standards, Review Literature as Topic, Time Factors, Bias, Patient Selection, Evidence-Based Medicine
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
A language model drew the claims from the paper on 2026-11-23, under version 3 of the claim definition (model deepseek-v4.1-flash, prompt extract-v3).
A second model labelled each claim on 2026-11-23 (model jev-1.13-20260917, definition revision gold-guideline-v0.2).
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.