QUADAS-2: A Revised Tool for the Quality Assessment of Diagnostic Accuracy Studies
Open accessThe DOI matches its Crossref record; 18 of the 18 references it cites were found in a registry or an index; none of the 21 sources its claims cite is checked for support yet.
Abstract
In 2003, the QUADAS tool for systematic reviews of diagnostic accuracy studies was developed. Experience, anecdotal reports, and feedback suggested areas for improvement; therefore, QUADAS-2 was developed. This tool comprises 4 domains: patient selection, index test, reference standard, and flow and timing. Each domain is assessed in terms of risk of bias, and the first 3 domains are also assessed in terms of concerns regarding applicability. Signalling questions are included to help judge risk of bias. The QUADAS-2 tool is applied in 4 phases: summarize the review question, tailor the tool and produce review-specific guidance, construct a flow diagram for the primary study, and judge bias and applicability. This tool will allow for more transparent rating of bias and applicability of primary diagnostic accuracy studies.
Overview
CoChat Summary
TL;DR
QUADAS-2 is a revised tool for assessing risk of bias and applicability in diagnostic accuracy studies, developed through a 4-stage evidence-based consensus process. It replaces the original QUADAS “yes/no/unclear” quality rating with domain-level judgments of low, high, or unclear risk of bias and concerns about applicability.
Key findings
- QUADAS-2 separates “quality” into risk of bias and concerns regarding applicability, defining quality as the degree to which diagnostic accuracy estimates avoided bias and the extent to which primary studies are applicable to the review question.
- The tool has 4 key domains—patient selection, index test, reference standard, and flow and timing—with the first 3 also assessed for applicability; it is completed in 4 phases and uses signaling questions to help judge risk of bias.
- Development drew on 4 reviews: 54 diagnostic accuracy reviews published between 2007 and 2009, structured feedback from 64 systematic reviewers who had used QUADAS, 101 studies on sources of bias and variation, and 8 studies evaluating QUADAS; a 1-day consensus meeting had 24 attendees, and piloting occurred in 5 reviews.
- Interrater reliability varied considerably, with better agreement on applicability than on risk of bias; all participants preferred QUADAS-2 to the original tool, but the authors could not currently include criteria for studies comparing multiple index tests because the evidence base was insufficient.
Methods
- Tool development followed Moher and colleagues’ 4-stage approach: define the scope, review the evidence base, hold a face-to-face consensus meeting, and refine through piloting.
- A steering group of 9 experts set the scope; the consensus meeting was held on 21 September 2010 in Birmingham, United Kingdom, with 24 attendees who split into groups of 4 to 6 participants; multiple rounds of piloting used online questionnaires and other feedback, including pairs of reviewers piloting QUADAS-2 in 5 reviews.
- No primary statistical analysis was reported; the work synthesized evidence reviews, consensus decisions, and pilot feedback to produce and refine the tool.
Limitations
- Stated: the authors decided they cannot currently include criteria for assessing studies that compare multiple index tests within QUADAS-2 because of the limited evidence base on risk of bias and sources of variation in such studies, and they plan future work on this topic.
- Stated: piloting showed poor interrater reliability and problems applying the domain on comparative accuracy studies; interrater reliability varied considerably overall, with better agreement on applicability than on risk of bias.
- Evident from the text: full details of the 4 evidence reviews were to be published separately, and the main text reports no quantitative reliability estimates, referring instead to an Appendix Table.
Model-written summary. Check it against the paper before relying on it.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
0 Valid · 0 Not valid · 16 Not checked · 24 Own results and interpretations
In the paper
“In a review on anti-cyclic citrullinated peptide antibodies for diagnosing rheumatoid arthritis (10), we found that some studies enrolled consecutive participants with confirmed diagnoses. In these studies, testing for anticyclic citrullinated peptide antibody showed greater sensitivity than in studies that included patients with suspected disease but an unconfirmed diagnosis (that is, difficult-t”
§ QUADAS-2: A Revised Tool for the Quality Assessment of Diagnostic Accuracy Studies > Signaling question 2: Was a case-control design avoided? Signaling question 3: Did the study avoid inappropriate exclusions?
What the sources say
- Not matchedcites [10]
The reference list we hold has no entry [10].
plainstates an association- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Not matched
A statement the paper makes itself — it cites no source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“Studies that make inappropriate exclusions (for example, not including”
§ QUADAS-2: A Revised Tool for the Quality Assessment of Diagnostic Accuracy Studies > Signaling question 2: Was a case-control design avoided? Signaling question 3: Did the study avoid inappropriate exclusions?
hedgedstates a possible cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
None of the sources cited for this claim could be matched to a paper, so there is nothing to check it against.
In the paper
“Because the accuracy of a test may depend on where it will be used in the diagnostic pathway, review authors are asked to describe patients in terms of setting, intended use of the index test, patient presentation, and previous testing (8,9).”
§ QUADAS-2: A Revised Tool for the Quality Assessment of Diagnostic Accuracy Studies > Phase 1: Review Question
What the sources say
- Not matchedcites [8]
The reference list we hold has no entry [8].
- Not matchedcites [9]
The reference list we hold has no entry [9].
hedgedstates a possible cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Not matched
In the paper
“Development of QUADAS-2 was based on the 4-stage approach proposed by Moher and colleagues (4): define the scope, review the evidence base, hold a face-to-face consensus meeting, and refine the tool through piloting.”
§ QUADAS-2: A Revised Tool for the Quality Assessment of Diagnostic Accuracy Studies > METHODS
What the sources say
- Not matchedcites [4]
The reference list we hold has no entry [4].
plainstates a cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: unclear — It is unclear whether the paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Not matched
None of the sources cited for this claim could be matched to a paper, so there is nothing to check it against.
In the paper
“Studies enrolling participants with known disease and a control group without the condition may similarly exaggerate diagnostic accuracy (7,11).”
§ QUADAS-2: A Revised Tool for the Quality Assessment of Diagnostic Accuracy Studies > Signaling question 2: Was a case-control design avoided? Signaling question 3: Did the study avoid inappropriate exclusions?
What the sources say
- Not matchedcites [7]
The reference list we hold has no entry [7].
- Not matchedcites [11]
The reference list we hold has no entry [11].
hedgedstates a possible cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Not matched
10 more claims
Create a free account to see all 40 claims and every source verdict.
- Probably not a substantial claim. 19
- It may state two separate claims as one. 16
- The quote only partly states this claim. 2
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“We assessed the study-level risk of bias with the QUADAS-2 tool”
In the citing paper
“We developed a revised risk-of-bias assessment tool to address these issues, incorporate advances in assessment of risk of bias used in other recently developed tools, 9 10 and integrate recent developments in estimation of intervention effects from randomised trials. 11”
From RoB 2: a revised tool for assessing risk of bias in randomised trials (2019) · cites this paper as [10]
In the citing paper
“Two reviewers independently assessed the quality of the included studies with the Quality Assessment of Diagnostic Accuracy Studies (Quadas-2) [33].”
From High-standard predictive equations for estimating body composition using bioelectrical impedance analysis: a systematic review (2024) · cites this paper as [33]
In the citing paper
“The quality of the selected studies was rigorously assessed using the Checklist for Artificial Intelligence in Medical Imaging (CLAIM) alongside the Quality Assessment of Diagnostic Accuracy Studies-2 (QUADAS-2).23,24”
From Artificial Intelligence Detection and Segmentation Models: A Systematic Review and Meta-Analysis of Brain Tumors in Magnetic Resonance Imaging (2024) · cites this paper as [24]
In the citing paper
“The methodological quality of each selected study was assessed according to the Quality Assessment of Diagnostic Accuracy Studies (QUADAS-2) checklist [15]”
From The diagnostic accuracy of digital, infrared and mercury-in-glass thermometers in measuring body temperature: a systematic review and network meta-analysis (2021) · cites this paper as [15]
20 more claims about this paper
Create a free account to see every claim other papers make about this one.
Citations
Cites
The Cochrane Collaboration's tool for assessing risk of bias in randomised trials
Higgins, J. P. T., Altman, D. G., Gotzsche, P. C., Juni, P., Moher, D., Oxman, A. D., Savovic, J., Schulz, K. F., Weeks, L., Sterne, J. A. C., et al. (2011) · BMJ · doi:10.1136/bmj.d5928 · Cited by 33,817
Self-citationWhiting, P., Rutjes, A. W., Reitsma, J. B., Bossuyt, P. M., & Kleijnen, J. (2003) · BMC Medical Research Methodology · doi:10.1186/1471-2288-3-25 · Cited by 3,592
Self-citationThe Hazards of Scoring the Quality of Clinical Trials for Meta-analysis
Jüni, P. (1999) · JAMA · doi:10.1001/jama.282.11.1054 · Cited by 1,981
Empirical evidence of design-related bias in studies of diagnostic tests.
Lijmer, J. G. (1999) · JAMA · doi:10.1001/jama.282.11.1061 · Cited by 1,861 · cited 2×
“Studies enrolling participants with known disease and a control group without the condition may similarly exaggerate diagnostic accuracy (7, 11).”
BackgroundGuidance for Developers of Health Research Reporting Guidelines
Moher, D., Schulz, K. F., Simera, I., & Altman, D. G. (2010) · PLoS Medicine · doi:10.1371/journal.pmed.1000217 · Cited by 1,437
Systematic Reviews of Diagnostic Test Accuracy
Leeflang, M. M. G., Deeks, J. J., Gatsonis, C., & Bossuyt, P. M. M. (2008) · Annals of Internal Medicine · doi:10.7326/0003-4819-149-12-200812160-00008 · Cited by 1,124
Self-citationSources of Variation and Bias in Studies of Diagnostic Accuracy: A Systematic Review
Whiting, P., Rutjes, A. W. S., Reitsma, J. B., Glas, A. S., Bossuyt, P. M. M., & Kleijnen, J. (2004) · Annals of Internal Medicine · doi:10.7326/0003-4819-140-3-200402030-00010 · Cited by 798 · cited 4×
“The third review was an update on sources of bias and variation in diagnostic accuracy studies that included 101 studies (7).”
BackgroundInfluentialSelf-citationEvaluation of QUADAS, a tool for the quality assessment of diagnostic accuracy studies
Whiting, P. F., Weswood, M. E., Rutjes, A. W., Reitsma, J. B., Bossuyt, P. N., & Kleijnen, J. (2006) · BMC Medical Research Methodology · doi:10.1186/1471-2288-6-9 · Cited by 769
Self-citationLeeflang, M. M. G., Moons, K. G. M., Reitsma, J. B., & Zwinderman, A. H. (2008) · Clinical Chemistry · doi:10.1373/clinchem.2007.096032 · Cited by 346 · cited 1×
“Test performance is likely to be poorer in an independent sample of patients in whom the same threshold is used (12).”
BackgroundSelf-citationNo role for quality scores in systematic reviews of diagnostic accuracy studies
Whiting, P., Harbord, R., & Kleijnen, J. (2005) · BMC Medical Research Methodology · doi:10.1186/1471-2288-5-19 · Cited by 337
Self-citation
Cited by
Items 501–600 of 14,770
“Interchangeability” of PD-L1 immunohistochemistry assays: a meta-analysis of diagnostic accuracy
Torlakovic, E., Lim, H. J., Adam, J., Barnes, P., Bigras, G., Chan, A. W. H., Cheung, C. C., Chung, J.-H., Couture, C., Fiset, P. O., et al. (2020) · Modern Pathology · doi:10.1038/s41379-019-0327-4 · Cited by 178
Conde‐Agudelo, A., Villar, J., Kennedy, S. H., & Papageorghiou, A. T. (2018) · Ultrasound in Obstetrics & Gynecology · doi:10.1002/uog.19117 · Cited by 171
Celeng, C., Leiner, T., Maurovich-Horvat, P., Merkely, B., de Jong, P., Dankbaar, J. W., van Es, H. W., Ghoshhajra, B. B., Hoffmann, U., & Takx, R. A. P. (2019) · JACC: Cardiovascular Imaging · doi:10.1016/j.jcmg.2018.07.022 · Cited by 170
Woo, S., Suh, C. H., Kim, S. Y., Cho, J. Y., Kim, S. H., & Moon, M. H. (2018) · American Journal of Roentgenology · doi:10.2214/ajr.18.19880 · Cited by 175
Chen, T.-J., Chung, Y.-W., Chang, H.-C. (., Chen, P.-Y., Wu, C.-R., Hsieh, S.-H., & Chiu, H.-Y. (2021) · International Journal of Nursing Studies · doi:10.1016/j.ijnurstu.2020.103782 · Cited by 164
Huang, C., Ma, Y., Wang, C., Jiang, M., Chung, L. Y. F., Lv, L., & Han, L. (2021) · Nursing Open · doi:10.1002/nop2.792 · Cited by 207
Telemedicine for detecting diabetic retinopathy: a systematic review and meta-analysis
Shi, L., Wu, H., Dong, J., Jiang, K., Lu, X., & Shi, J. (2015) · British Journal of Ophthalmology · doi:10.1136/bjophthalmol-2014-305631 · Cited by 174
Endometrial biomarkers for the non-invasive diagnosis of endometriosis
Gupta, D., Hull, M. L., Fraser, I., Miller, L., Bossuyt, P. M., Johnson, N., & Nisenblat, V. (2016) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd012165 · Cited by 169
Self-citationHerlin, C., Kjaer, P., Espeland, A., Skouen, J. S., Leboeuf-Yde, C., Karppinen, J., Niinimäki, J., Sørensen, J. S., Storheim, K., & Jensen, T. S. (2018) · PLOS ONE · doi:10.1371/journal.pone.0200677 · Cited by 162
COVID-19-related medical research: a meta-research and critical appraisal
Raynaud, M., Zhang, H., Louis, K., Goutaudier, V., Wang, J., Dubourg, Q., Wei, Y., Demir, Z., Debiais, C., Aubert, O., et al. (2021) · BMC Medical Research Methodology · doi:10.1186/s12874-020-01190-w · Cited by 172
Sleep and Pain: A Systematic Review of Studies of Mediation
Whibley, D., AlKandari, N., Kristensen, K., Barnish, M., Rzewuska, M., Druce, K. L., & Tang, N. K. Y. (2019) · The Clinical Journal of Pain · doi:10.1097/ajp.0000000000000697 · Cited by 178
Tsai, A. C., Scott, J. A., Hung, K. J., Zhu, J. Q., Matthews, L. T., Psaros, C., & Tomlinson, M. (2013) · PLoS ONE · doi:10.1371/journal.pone.0082521 · Cited by 169
“For studies assessing criterion-related validity, data were extracted on the numbers of participants classified as true positives, true negatives, false positives, and false negatives, as well as items necessary to assess study quality according to the revised Quality Assessment of Diagnostic Accuracy Studies (QUADAS-…”
Lateral flow urine lipoarabinomannan assay for detecting active tuberculosis in HIV-positive adults
Shah, M., Hanrahan, C., Wang, Z. Y., Dendukuri, N., Lawn, S. D., Denkinger, C. M., & Steingart, K. R. (2016) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd011420.pub2 · Cited by 173
Payne, C. L., Scarborough, P., & Cobiac, L. (2016) · Public Health Nutrition · doi:10.1017/s1368980016000495 · Cited by 176
AGA Clinical Practice Guideline on the Role of Biomarkers for the Management of Ulcerative Colitis
Singh, S., Ananthakrishnan, A. N., Nguyen, N. H., Cohen, B. L., Velayos, F. S., Weiss, J. M., Sultan, S., Siddique, S. M., Adler, J., & Chachu, K. A. (2023) · Gastroenterology · doi:10.1053/j.gastro.2022.12.007 · Cited by 165
Westwood, M., Al, M., Burgers, L., Redekop, K., Lhachimi, S., Armstrong, N., Raatz, H., Misso, K., Severens, J., & Kleijnen, J. (2013) · Health Technology Assessment · doi:10.3310/hta17090 · Cited by 175
Self-citationBai, A. D., Steinberg, M., Showler, A., Burry, L., Bhatia, R. S., Tomlinson, G. A., Bell, C. M., & Morris, A. M. (2017) · Journal of the American Society of Echocardiography · doi:10.1016/j.echo.2017.03.007 · Cited by 168
Symptom Signatures and Diagnostic Timeliness in Cancer Patients: A Review of Current Evidence
Koo, M. M., Hamilton, W., Walter, F. M., Rubin, G. P., & Lyratzopoulos, G. (2018) · Neoplasia · doi:10.1016/j.neo.2017.11.005 · Cited by 174
Diagnostic performance of imaging for the detection of peritoneal metastases: a meta-analysis
van ’t Sant, I., Engbersen, M. P., Bhairosing, P. A., Lambregts, D. M. J., Beets-Tan, R. G. H., van Driel, W. J., Aalbers, A. G. J., Kok, N. F. M., & Lahaye, M. J. (2020) · European Radiology · doi:10.1007/s00330-019-06524-x · Cited by 173
Pan, J. A., Kerwin, M. J., & Salerno, M. (2020) · JACC: Cardiovascular Imaging · doi:10.1016/j.jcmg.2020.03.010 · Cited by 173
Lung ultrasound for the diagnosis of pneumonia in adults: A meta-analysis
Long, L., Zhao, H.-T., Zhang, Z.-Y., Wang, G.-Y., & Zhao, H.-L. (2017) · Medicine · doi:10.1097/md.0000000000005713 · Cited by 169
Mondello, S., Sorinola, A., Czeiter, E., Vámos, Z., Amrein, K., Synnot, A., Donoghue, E., Sándor, J., Wang, K. K. W., Diaz-Arrastia, R., et al. (2021) · Journal of Neurotrauma · doi:10.1089/neu.2017.5182 · Cited by 167
Sensitivity and Safety of Electromagnetic Navigation Bronchoscopy for Lung Cancer Diagnosis
Folch, E. E., Labarca, G., Ospina-Delgado, D., Kheir, F., Majid, A., Khandhar, S. J., Mehta, H. J., Jantz, M. A., & Fernandez-Bussy, S. (2020) · Chest · doi:10.1016/j.chest.2020.05.534 · Cited by 174
Maleki, F., Ovens, K., Gupta, R., Reinhold, C., Spatz, A., & Forghani, R. (2023) · Radiology: Artificial Intelligence · doi:10.1148/ryai.220028 · Cited by 150
Teledermatology for diagnosing skin cancer in adults.
Chuchu, N., Dinnes, J., Takwoingi, Y., Matin, R. N., Bayliss, S. E., Davenport, C., Moreau, J. F., Bassett, O., Godfrey, K., O'Sullivan, C., et al. (2018) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd013193 · Cited by 175
Self-citationCheng, F., Yuan, Q., Yang, J., Wang, W., & Liu, H. (2014) · PLoS ONE · doi:10.1371/journal.pone.0106680 · Cited by 167
Schuetz, G. M., Schlattmann, P., & Dewey, M. (2012) · BMJ · doi:10.1136/bmj.e6717 · Cited by 176
Validated Smartphone-Based Apps for Ear and Hearing Assessments: A Review
Bright, T., & Pallawela, D. (2016) · JMIR Rehabilitation and Assistive Technologies · doi:10.2196/rehab.6074 · Cited by 170
Mallett, S., Allen, A. J., Graziadio, S., Taylor, S. A., Sakai, N. S., Green, K., Suklan, J., Hyde, C., Shinkins, B., Zhelev, Z., et al. (2020) · BMC Medicine · doi:10.1186/s12916-020-01810-8 · Cited by 162
Self-citationBlood-based biomarkers of inflammation in mild traumatic brain injury: A systematic review
Visser, K., Koggel, M., Blaauw, J., van der Horn, H. J., Jacobs, B., & van der Naalt, J. (2021) · Neuroscience & Biobehavioral Reviews · doi:10.1016/j.neubiorev.2021.11.036 · Cited by 186
Van Meter, A. R., Burke, C., Youngstrom, E. A., Faedda, G. L., & Correll, C. U. (2016) · Journal of the American Academy of Child & Adolescent Psychiatry · doi:10.1016/j.jaac.2016.04.017 · Cited by 174
Rapid tests for the diagnosis of visceral leishmaniasis in patients with suspected disease
Boelaert, M., Verdonck, K., Menten, J., Sunyoto, T., van Griensven, J., Chappuis, F., & Rijal, S. (2014) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd009135.pub2 · Cited by 168
McGill, S. K., Evangelou, E., Ioannidis, J. P. A., Soetikno, R. M., & Kaltenbach, T. (2013) · Gut · doi:10.1136/gutjnl-2012-303965 · Cited by 174
Govers, T. M., Hannink, G., Merkx, M. A. W., Takes, R. P., & Rovers, M. M. (2013) · Oral Oncology · doi:10.1016/j.oraloncology.2013.04.006 · Cited by 170
When Assessment Data Are Words: Validity Evidence for Qualitative Educational Assessments
Cook, D. A., Kuper, A., Hatala, R., & Ginsburg, S. (2016) · Academic Medicine · doi:10.1097/acm.0000000000001175 · Cited by 155
van Es, N., van der Hulle, T., van Es, J., den Exter, P. L., Douma, R. A., Goekoop, R. J., Mos, I. C. M., Galipienzo, J., Kamphuisen, P. W., Huisman, M. V., et al. (2016) · Annals of Internal Medicine · doi:10.7326/m16-0031 · Cited by 163
Self-citationThe Diagnostic Concordance of Whole Slide Imaging and Light Microscopy: A Systematic Review
Goacher, E., Randell, R., Williams, B., & Treanor, D. (2017) · Archives of Pathology & Laboratory Medicine · doi:10.5858/arpa.2016-0025-ra · Cited by 173
Meeralam, Y., Al-Shammari, K., & Yaghoobi, M. (2017) · Gastrointestinal Endoscopy · doi:10.1016/j.gie.2017.06.009 · Cited by 168
State-of-the-art of FAPI-PET imaging: a systematic review and meta-analysis
Sollini, M., Kirienko, M., Gelardi, F., Fiz, F., Gozzi, N., & Chiti, A. (2021) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-021-05475-0 · Cited by 168
Bhanji, F., Finn, J. C., Lockey, A., Monsieurs, K., Frengley, R., Iwami, T., Lang, E., Ma, M. H.-M., Mancini, M. E., McNeil, M. A., et al. (2015) · Circulation · doi:10.1161/cir.0000000000000277 · Cited by 172
Kondo, Y., Umemura, Y., Hayashida, K., Hara, Y., Aihara, M., & Yamakawa, K. (2019) · Journal of Intensive Care · doi:10.1186/s40560-019-0374-4 · Cited by 166
Medeiros, L. R., Rosa, M. I., Silva, B. R., Reis, M. E., Simon, C. S., Dondossola, E. R., & da Cunha Filho, J. S. (2015) · Archives of Gynecology and Obstetrics · doi:10.1007/s00404-014-3470-7 · Cited by 170
Gopalakrishna, G., Mustafa, R. A., Davenport, C., Scholten, R. J. P. M., Hyde, C., Brozek, J., Schünemann, H. J., Bossuyt, P. M. M., Leeflang, M. M. G., & Langendam, M. W. (2014) · Journal of Clinical Epidemiology · doi:10.1016/j.jclinepi.2014.01.006 · Cited by 168
Self-citationSinclair, A., Xie, X., Teltscher, M., & Dendukuri, N. (2013) · Journal of Clinical Microbiology · doi:10.1128/jcm.00137-13 · Cited by 168
Roth, D., Pace, N. L., Lee, A., Hovhannisyan, K., Warenits, A. M., Arrich, J., & Herkner, H. (2019) · Anaesthesia · doi:10.1111/anae.14608 · Cited by 160
Reiman, M. P., Agricola, R., Kemp, J. L., Heerey, J., Weir, A., van Klij, P., Kassarjian, A., Mosler, A., Ageberg, E., Hölmich, P., et al. (2020) · British Journal of Sports Medicine · doi:10.1136/bjsports-2019-101453 · Cited by 194
Pötsch, N., Vatteroni, G., Clauser, P., Helbich, T. H., & Baltzer, P. A. T. (2022) · Radiology · doi:10.1148/radiol.212530 · Cited by 162
Moos, S. I., van Vemde, D. N. H., Stoker, J., & Bipat, S. (2013) · European Journal of Radiology · doi:10.1016/j.ejrad.2013.04.029 · Cited by 166
Zhang, L., Tang, M., Min, Z., Lu, J., Lei, X., & Zhang, X. (2016) · Acta Radiologica · doi:10.1177/0284185115597265 · Cited by 169
A practical guide to validation and verification of analytical methods in the clinical laboratory
Pum, J. K. W. (2019) · Advances in clinical chemistry · doi:10.1016/bs.acc.2019.01.006 · Cited by 221
Clinical Practice Guideline for Endoscopic Resection of Early Gastrointestinal Cancer
Park, C. H., Yang, D.-H., Kim, J. W., Kim, J.-H., Kim, J. H., Min, Y. W., Lee, S. H., Bae, J. H., Chung, H., Choi, K. D., et al. (2020) · Clinical Endoscopy · doi:10.5946/ce.2020.032 · Cited by 161
“The QUADAS-2 tool was used for diagnostic studies.(21) The GRADE method was used to present summaries of evidence.”
Cao, Y.-T., Xiang, L.-L., Qi, F., Zhang, Y., Chen, Y., & Zhou, X. (2022) · EClinicalMedicine · doi:10.1016/j.eclinm.2022.101547 · Cited by 192
EASL Clinical Practice Guidelines on the management of autoimmune hepatitis
Dalekos, G., Gatselis, N., Drenth, J. P. H., Heneghan, M., Jørgensen, M., Lohse, A. W., Londoño, M., Muratori, L., Papp, M., Samyn, M., et al. (2025) · Journal of Hepatology · doi:10.1016/j.jhep.2025.03.017 · Cited by 236
Crossan, C., Tsochatzis, E. A., Longworth, L., Gurusamy, K., Davidson, B., Rodríguez-Perálvarez, M., Mantzoukis, K., O’Brien, J., Thalassinos, E., Papastergiou, V., et al. (2015) · Health Technology Assessment · doi:10.3310/hta19090 · Cited by 164
Mahmood, H., Shaban, M., Indave, B. I., Santos-Silva, A. R., Rajpoot, N., & Khurram, S. A. (2020) · Oral Oncology · doi:10.1016/j.oraloncology.2020.104885 · Cited by 161
Guidelines for the diagnosis and treatment of osteoarthritis in China (2019 edition)
Zhang, Z., Huang, C., Jiang, Q., Zheng, Y., Liu, Y., Liu, S., Chen, Y., Mei, Y., Ding, C., Chen, M., et al. (2020) · Annals of Translational Medicine · doi:10.21037/atm-20-4665 · Cited by 166
“21037/atm-20-4665 RCTs] (23), diagnostic quality assessment tools (Quality Assessment of Diagnostic Accuracy Studies, QUADAS-2, for diagnostic accuracy tests) (24), Newcastle-Ottawa Scale (NOS, for observational studies) (25) and other methodological quality evaluation of the corresponding type of original research; t…”
Koçak, B., Ponsiglione, A., Stanzione, A., Bluethgen, C., Santinha, J., Ugga, L., Huisman, M., Klontzas, M. E., Cannella, R., & Cuocolo, R. (2024) · Diagnostic and Interventional Radiology · doi:10.4274/dir.2024.242854 · Cited by 168
“62 The QUADAS-2 tool includes 14 questions and provides an estimate of the risk of bias in the study, categorizing it as high, low, or unclear.”
Adams, H. J. A., Kwee, T. C., de Keizer, B., Fijnheer, R., de Klerk, J. M. H., & Nievelstein, R. A. J. (2014) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-013-2623-4 · Cited by 167
Diao, K.-Y., Yang, Z.-G., Xu, H.-Y., Liu, X., Zhang, Q., Shi, K., Jiang, L., Xie, L.-J., Wen, L.-Y., & Guo, Y.-K. (2016) · Journal of Cardiovascular Magnetic Resonance · doi:10.1186/s12968-016-0313-7 · Cited by 167
Zheng, X.-Y., Xu, Y.-J., Guan, W.-J., & Lin, L.-F. (2018) · Archives of Virology · doi:10.1007/s00705-017-3700-y · Cited by 171
Ursprung, S., Beer, L., Bruining, A., Woitek, R., Stewart, G. D., Gallagher, F. A., & Sala, E. (2020) · European Radiology · doi:10.1007/s00330-020-06666-3 · Cited by 158
Guerriero, S., Ajossa, S., Orozco, R., Perniciano, M., Jurado, M., Melis, G. B., & Alcazar, J. L. (2016) · Ultrasound in Obstetrics & Gynecology · doi:10.1002/uog.15662 · Cited by 167
Lehrnbecher, T., Robinson, P. D., Fisher, B. T., Castagnola, E., Groll, A. H., Steinbach, W. J., Zaoutis, T. E., Negeri, Z. F., Beyene, J., Phillips, B., et al. (2016) · Clinical Infectious Diseases · doi:10.1093/cid/ciw592 · Cited by 166
Nathavitharana, R. R., Cudahy, P. G. T., Schumacher, S. G., Steingart, K. R., Pai, M., & Denkinger, C. M. (2017) · European Respiratory Journal · doi:10.1183/13993003.01075-2016 · Cited by 158
Collet, C., Onuma, Y., Sonck, J., Asano, T., Vandeloo, B., Kornowski, R., Tu, S., Westra, J., Holm, N. R., Xu, B., et al. (2018) · European Heart Journal · doi:10.1093/eurheartj/ehy445 · Cited by 165
Nolan, J. P., Hazinski, M. F., Aickin, R., Bhanji, F., Billi, J. E., Callaway, C. W., Castren, M., de Caen, A. R., Ferrer, J. M. E., Finn, J. C., et al. (2015) · Resuscitation · doi:10.1016/j.resuscitation.2015.07.039 · Cited by 161
Ritchie, C., Smailagic, N., Noel-Storr, A. H., Takwoingi, Y., Flicker, L., Mason, S. E., & McShane, R. (2014) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd008782.pub4 · Cited by 159
Accuracy of Presepsin in Sepsis Diagnosis: A Systematic Review and Meta-Analysis
Wu, J., Hu, L., Zhang, G., Wu, F., & He, T. (2015) · PLOS ONE · doi:10.1371/journal.pone.0133057 · Cited by 158
Rossi, A. C., & Prefumo, F. (2014) · Ultrasound in Obstetrics & Gynecology · doi:10.1002/uog.13429 · Cited by 161
Confusion assessment method: a systematic review and meta-analysis of diagnostic accuracy
Shi, Q., Warren, Saposnik, & MacDermid (2013) · Neuropsychiatric Disease and Treatment · doi:10.2147/ndt.s49520 · Cited by 160
Li, Y., Huang, Y.-S., Wang, Z.-Z., Yang, Z.-R., Sun, F., Zhan, S.-Y., Liu, X.-E., & Zhuang, H. (2016) · Alimentary Pharmacology & Therapeutics · doi:10.1111/apt.13488 · Cited by 161
Depression screening tools in persons with epilepsy: A systematic review of validated tools
Gill, S. J., Lukmanji, S., Fiest, K. M., Patten, S. B., Wiebe, S., & Jetté, N. (2017) · Epilepsia · doi:10.1111/epi.13651 · Cited by 160
Weissberger, G. H., Strong, J. V., Stefanidis, K. B., Summers, M. J., Bondi, M. W., & Stricker, N. H. (2017) · Neuropsychology Review · doi:10.1007/s11065-017-9360-6 · Cited by 150
Familiari, A., Liberati, M., Lim, P., Pagani, G., Cali, G., Buca, D., Manzoli, L., Flacco, M. E., Scambia, G., & D'antonio, F. (2018) · Acta Obstetricia et Gynecologica Scandinavica · doi:10.1111/aogs.13258 · Cited by 162
Performance of Five Ultrasound Risk Stratification Systems in Selecting Thyroid Nodules for FNA
Castellana, M., Castellana, C., Treglia, G., Giorgino, F., Giovanella, L., Russ, G., & Trimboli, P. (2020) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/clinem/dgz170 · Cited by 159
Bastos, M. L., Perlman-Arrow, S., Menzies, D., & Campbell, J. R. (2021) · Annals of Internal Medicine · doi:10.7326/m20-6569 · Cited by 162
Fu, H., Wang, L., Zhang, W., Lü, J., & Yang, M. J. (2022) · Journal of Cachexia Sarcopenia and Muscle · doi:10.1002/jcsm.13149 · Cited by 184
Qiu, X., Lei, Y., & Zhou, R. (2023) · Expert Review of Anti-infective Therapy · doi:10.1080/14787210.2023.2237192 · Cited by 200
Vilgrain, V., Esvan, M., Ronot, M., Caumont-Prim, A., Aubé, C., & Chatellier, G. (2016) · European Radiology · doi:10.1007/s00330-016-4250-5 · Cited by 166
“Quality assessment The methodological quality of the included studies was assessed independently by two observers in duplicate using QUADAS-2, a quality assessment tool developed for the systematic review of diagnostic accuracy studies [20].”
Scaletta, G., Plotti, F., Luvero, D., Capriglione, S., Montera, R., Miranda, A., Lopez, S., Terranova, C., De Cicco Nardone, C., & Angioli, R. (2017) · Expert Review of Anticancer Therapy · doi:10.1080/14737140.2017.1360138 · Cited by 163
Nabipoorashrafi, S. A., Seyedi, S. A., Rabizadeh, S., Ebrahimi, M., Ranjbar, S. A., Reyhan, S. K., Meysamie, A., Nakhjavani, M., & Esteghamati, A. (2022) · Nutrition Metabolism and Cardiovascular Diseases · doi:10.1016/j.numecd.2022.07.024 · Cited by 182
Physiological Factors Related to Aspiration Risk: A Systematic Review
Steele, C. M., & Cichero, J. A. Y. (2014) · Dysphagia · doi:10.1007/s00455-014-9516-y · Cited by 150
Laghi, A., Bellini, D., Rengo, M., Accarpio, F., Caruso, D., Biacchi, D., Giorgio, A. D., & Sammartino, P. (2016) · La radiologia medica · doi:10.1007/s11547-016-0682-x · Cited by 171
Wang, M., He, X., Chang, Y., Sun, G., & Thabane, L. (2016) · The Breast · doi:10.1016/j.breast.2016.11.009 · Cited by 199
Mileva, N. B., Nagumo, S., Mizukami, T., Sonck, J., Berry, C., Gallinoro, E., Monizzi, G., Candreva, A., Munhoz, D., Vassilev, D. I., et al. (2022) · Zurich Open Repository and Archive (University of Zurich) · doi:10.5167/uzh-229326 · Cited by 164
Lauri, C., Tamminga, M., Glaudemans, A. W. J. M., Juárez Orozco, L. E., Erba, P. A., Jutte, P. C., Lipsky, B. A., IJzerman, M. J., Signore, A., & Slart, R. H. J. A. (2017) · Diabetes Care · doi:10.2337/dc17-0532 · Cited by 163
Westwood, M., van Asselt, T., Ramaekers, B., Whiting, P., Thokala, P., Joore, M., Armstrong, N., Ross, J., Severens, J., & Kleijnen, J. (2015) · Health Technology Assessment · doi:10.3310/hta19440 · Cited by 161
Self-citationFan, L.-C., Lu, H.-W., Cheng, K.-B., Li, H.-P., & Xu, J.-F. (2013) · PLoS ONE · doi:10.1371/journal.pone.0073099 · Cited by 159
Accuracy of FENOfor diagnosing asthma: a systematic review
Karrasch, S., Linde, K., Rücker, G., Sommer, H., Karsch-Völk, M., Kleijnen, J., Jörres, R. A., & Schneider, A. (2017) · Thorax · doi:10.1136/thoraxjnl-2016-208704 · Cited by 160
Garcia, M., Agar, M. R., Soo, W. K., To, T. H. M., & Phillips, J. L. (2021) · JAMA Oncology · doi:10.1001/jamaoncol.2020.6736 · Cited by 174
Opioid Treatments for Chronic Pain
Chou, R., Hartung, D., Turner, J., Blazina, I., Chan, B., Levander, X., McDonagh, M., Selph, S., Fu, R., & Pappas, M. (2020) · doi:10.23970/ahrqepccer229 · Cited by 152
Understanding Sources of Bias in Diagnostic Accuracy Studies
Schmidt, R. L., & Factor, R. E. (2013) · Archives of Pathology & Laboratory Medicine · doi:10.5858/arpa.2012-0198-ra · Cited by 184
Zhao, L., Tian, Z., & Fang, Q. (2016) · BMC Cardiovascular Disorders · doi:10.1186/s12872-016-0311-6 · Cited by 160
Juneau, D., Golfam, M., Hazra, S., Zuckier, L. S., Garas, S., Redpath, C., Bernick, J., Leung, E., Chih, S., Wells, G., et al. (2017) · Circulation: Cardiovascular Imaging · doi:10.1161/circimaging.116.005772 · Cited by 160
Bouthoorn, S., Valstar, G. B., Gohar, A., den Ruijter, H. M., Reitsma, H. B., Hoes, A. W., & Rutten, F. H. (2018) · Diabetes and Vascular Disease Research · doi:10.1177/1479164118787415 · Cited by 155
Self-citationWestwood, M., Ramaekers, B., Lang, S., Grimm, S., Deshpande, S., de Kock, S., Armstrong, N., Joore, M., & Kleijnen, J. (2018) · Health Technology Assessment · doi:10.3310/hta22440 · Cited by 161
Self-citationHatt, M., Krizsan, A. K., Rahmim, A., Bradshaw, T., Costa, P. F., Forgács, A., Seifert, R., Zwanenburg, A., Naqa, I. E., Kinahan, P. E., et al. (2022) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-022-06001-6 · Cited by 177
Neuropathic pain screening questionnaires have limited measurement properties. A systematic review
Mathieson, S., Maher, C. G., Terwee, C. B., de Campos, T. F., & Lin, C. C. (2015) · Journal of Clinical Epidemiology · doi:10.1016/j.jclinepi.2015.03.010 · Cited by 183
Meng, Q., Shi, S., Liang, C., Liang, D., Xu, W., Ji, S., Zhang, B., Ni, Q., Xu, J., & Yu, X. (2017) · OncoTargets and Therapy · doi:10.2147/ott.s145708 · Cited by 173
“16 The criteria consist of four key domains, including 1) patient selection; 2) conduct of the index test; 3) reference standard; and 4) flow and timing.”
Sukriti, K. C., Wang, X. Z., & Gallagher, J. E. (2019) · Journal Of Clinical Periodontology · doi:10.1111/jcpe.13218 · Cited by 176
Metadata
- Authors
- Whiting, P. F., Rutjes, A. W. S., Westwood, M. E., Mallett, S., Deeks, J. J., Reitsma, J. B., Leeflang, M. M. G., Sterne, J. A. C., Bossuyt, P. M. M., & the QUADAS-2 Group*
- Affiliations
- University of Bern (CH)
- Corresponding author
- Whiting, Penny F.
- ORCID
- Venue
- Annals of Internal Medicine
- Publisher
- American College of Physicians
- Published
- 2011-10-18
- Volume
- 155
- Issue
- 8
- Pages
- 529-536
- ISSN
- 0003-4819 (ISSN-L)
- 1539-3704
- OpenAlex
- W2107638293
- Semantic Scholar
- 8a5d0b5a9271ea14bcb8479bc32d3844a80655b9
- Cited by
- 14,199
- References
- 18
- Citations by year
- 2026: 1484 · 2025: 1569 · 2024: 1524 · 2023: 1305 · 2022: 1420 · 2021: 1514 · 2020: 1245 · 2019: 955 · 2018: 767 · 2017: 637 · 2016: 580 · 2015: 528 · 2014: 363 · 2013: 217 · 2012: 75
- FWCI
- 224.36
- Type
- journal article
- Language
- en
- Open access
- green
- hdl.handle.net
- Licence
- cc-by
- www.acpjournals.org/journal/aim/text-and-data-mining (tdm)
- Locations
- Annals of Internal Medicine (publishedVersion)
- PubMed (publishedVersion)
- Pure Amsterdam UMC (publishedVersion)
- Data Archiving and Networked Services (DANS) (submittedVersion)
- Florence Research (University of Florence) (submittedVersion)
- IRIS UNIMORE (University of Modena and Reggio Emilia) (submittedVersion, cc-by)
- University of Birmingham Research Portal (University of Birmingham) (submittedVersion)
- Bristol Research (University of Bristol) (submittedVersion)
- Funders
- Cancer Research UK
- Topics
- Social Sciences › Decision Sciences › Statistics, Probability and Uncertainty › Meta-analysis and systematic reviews
- Physical Sciences › Mathematics › Statistics and Probability › Statistical Methods in Epidemiology
- Health Sciences › Medicine › Public Health, Environmental and Occupational Health › Clinical practice guidelines implementation
- Keywords
- QUADAS-2, diagnostic accuracy studies, quality assessment, risk of bias, applicability, patient selection, index tests, reference materials, flowcharts, systematic reviews
- MeSH terms
- Diagnosis, Humans, Quality Control, Surveys and Questionnaires, Reference Standards, Review Literature as Topic, Time Factors, Bias, Patient Selection, Evidence-Based Medicine
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
A language model drew the claims from the paper on 2026-11-23, under version 3 of the claim definition (model deepseek-v4.1-flash, prompt extract-v3).
A second model labelled each claim on 2026-11-23 (model jev-1.13-20260917, definition revision gold-guideline-v0.2).
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.