QUADAS-2: A Revised Tool for the Quality Assessment of Diagnostic Accuracy Studies
Open accessThe DOI matches its Crossref record; 18 of the 18 references it cites were found in a registry or an index; none of the 21 sources its claims cite is checked for support yet.
Abstract
In 2003, the QUADAS tool for systematic reviews of diagnostic accuracy studies was developed. Experience, anecdotal reports, and feedback suggested areas for improvement; therefore, QUADAS-2 was developed. This tool comprises 4 domains: patient selection, index test, reference standard, and flow and timing. Each domain is assessed in terms of risk of bias, and the first 3 domains are also assessed in terms of concerns regarding applicability. Signalling questions are included to help judge risk of bias. The QUADAS-2 tool is applied in 4 phases: summarize the review question, tailor the tool and produce review-specific guidance, construct a flow diagram for the primary study, and judge bias and applicability. This tool will allow for more transparent rating of bias and applicability of primary diagnostic accuracy studies.
Overview
CoChat Summary
TL;DR
QUADAS-2 is a revised tool for assessing risk of bias and applicability in diagnostic accuracy studies, developed through a 4-stage evidence-based consensus process. It replaces the original QUADAS “yes/no/unclear” quality rating with domain-level judgments of low, high, or unclear risk of bias and concerns about applicability.
Key findings
- QUADAS-2 separates “quality” into risk of bias and concerns regarding applicability, defining quality as the degree to which diagnostic accuracy estimates avoided bias and the extent to which primary studies are applicable to the review question.
- The tool has 4 key domains—patient selection, index test, reference standard, and flow and timing—with the first 3 also assessed for applicability; it is completed in 4 phases and uses signaling questions to help judge risk of bias.
- Development drew on 4 reviews: 54 diagnostic accuracy reviews published between 2007 and 2009, structured feedback from 64 systematic reviewers who had used QUADAS, 101 studies on sources of bias and variation, and 8 studies evaluating QUADAS; a 1-day consensus meeting had 24 attendees, and piloting occurred in 5 reviews.
- Interrater reliability varied considerably, with better agreement on applicability than on risk of bias; all participants preferred QUADAS-2 to the original tool, but the authors could not currently include criteria for studies comparing multiple index tests because the evidence base was insufficient.
Methods
- Tool development followed Moher and colleagues’ 4-stage approach: define the scope, review the evidence base, hold a face-to-face consensus meeting, and refine through piloting.
- A steering group of 9 experts set the scope; the consensus meeting was held on 21 September 2010 in Birmingham, United Kingdom, with 24 attendees who split into groups of 4 to 6 participants; multiple rounds of piloting used online questionnaires and other feedback, including pairs of reviewers piloting QUADAS-2 in 5 reviews.
- No primary statistical analysis was reported; the work synthesized evidence reviews, consensus decisions, and pilot feedback to produce and refine the tool.
Limitations
- Stated: the authors decided they cannot currently include criteria for assessing studies that compare multiple index tests within QUADAS-2 because of the limited evidence base on risk of bias and sources of variation in such studies, and they plan future work on this topic.
- Stated: piloting showed poor interrater reliability and problems applying the domain on comparative accuracy studies; interrater reliability varied considerably overall, with better agreement on applicability than on risk of bias.
- Evident from the text: full details of the 4 evidence reviews were to be published separately, and the main text reports no quantitative reliability estimates, referring instead to an Appendix Table.
Model-written summary. Check it against the paper before relying on it.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
0 Valid · 0 Not valid · 16 Not checked · 24 Own results and interpretations
In the paper
“In a review on anti-cyclic citrullinated peptide antibodies for diagnosing rheumatoid arthritis (10), we found that some studies enrolled consecutive participants with confirmed diagnoses. In these studies, testing for anticyclic citrullinated peptide antibody showed greater sensitivity than in studies that included patients with suspected disease but an unconfirmed diagnosis (that is, difficult-t”
§ QUADAS-2: A Revised Tool for the Quality Assessment of Diagnostic Accuracy Studies > Signaling question 2: Was a case-control design avoided? Signaling question 3: Did the study avoid inappropriate exclusions?
What the sources say
- Not matchedcites [10]
The reference list we hold has no entry [10].
plainstates an association- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Not matched
A statement the paper makes itself — it cites no source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“Studies that make inappropriate exclusions (for example, not including”
§ QUADAS-2: A Revised Tool for the Quality Assessment of Diagnostic Accuracy Studies > Signaling question 2: Was a case-control design avoided? Signaling question 3: Did the study avoid inappropriate exclusions?
hedgedstates a possible cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
None of the sources cited for this claim could be matched to a paper, so there is nothing to check it against.
In the paper
“Because the accuracy of a test may depend on where it will be used in the diagnostic pathway, review authors are asked to describe patients in terms of setting, intended use of the index test, patient presentation, and previous testing (8,9).”
§ QUADAS-2: A Revised Tool for the Quality Assessment of Diagnostic Accuracy Studies > Phase 1: Review Question
What the sources say
- Not matchedcites [8]
The reference list we hold has no entry [8].
- Not matchedcites [9]
The reference list we hold has no entry [9].
hedgedstates a possible cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Not matched
In the paper
“Development of QUADAS-2 was based on the 4-stage approach proposed by Moher and colleagues (4): define the scope, review the evidence base, hold a face-to-face consensus meeting, and refine the tool through piloting.”
§ QUADAS-2: A Revised Tool for the Quality Assessment of Diagnostic Accuracy Studies > METHODS
What the sources say
- Not matchedcites [4]
The reference list we hold has no entry [4].
plainstates a cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: unclear — It is unclear whether the paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Not matched
None of the sources cited for this claim could be matched to a paper, so there is nothing to check it against.
In the paper
“Studies enrolling participants with known disease and a control group without the condition may similarly exaggerate diagnostic accuracy (7,11).”
§ QUADAS-2: A Revised Tool for the Quality Assessment of Diagnostic Accuracy Studies > Signaling question 2: Was a case-control design avoided? Signaling question 3: Did the study avoid inappropriate exclusions?
What the sources say
- Not matchedcites [7]
The reference list we hold has no entry [7].
- Not matchedcites [11]
The reference list we hold has no entry [11].
hedgedstates a possible cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Not matched
10 more claims
Create a free account to see all 40 claims and every source verdict.
- Probably not a substantial claim. 19
- It may state two separate claims as one. 16
- The quote only partly states this claim. 2
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“We assessed the study-level risk of bias with the QUADAS-2 tool”
In the citing paper
“We developed a revised risk-of-bias assessment tool to address these issues, incorporate advances in assessment of risk of bias used in other recently developed tools, 9 10 and integrate recent developments in estimation of intervention effects from randomised trials. 11”
From RoB 2: a revised tool for assessing risk of bias in randomised trials (2019) · cites this paper as [10]
In the citing paper
“Two reviewers independently assessed the quality of the included studies with the Quality Assessment of Diagnostic Accuracy Studies (Quadas-2) [33].”
From High-standard predictive equations for estimating body composition using bioelectrical impedance analysis: a systematic review (2024) · cites this paper as [33]
In the citing paper
“The quality of the selected studies was rigorously assessed using the Checklist for Artificial Intelligence in Medical Imaging (CLAIM) alongside the Quality Assessment of Diagnostic Accuracy Studies-2 (QUADAS-2).23,24”
From Artificial Intelligence Detection and Segmentation Models: A Systematic Review and Meta-Analysis of Brain Tumors in Magnetic Resonance Imaging (2024) · cites this paper as [24]
In the citing paper
“The methodological quality of each selected study was assessed according to the Quality Assessment of Diagnostic Accuracy Studies (QUADAS-2) checklist [15]”
From The diagnostic accuracy of digital, infrared and mercury-in-glass thermometers in measuring body temperature: a systematic review and network meta-analysis (2021) · cites this paper as [15]
20 more claims about this paper
Create a free account to see every claim other papers make about this one.
Citations
Cites
The Cochrane Collaboration's tool for assessing risk of bias in randomised trials
Higgins, J. P. T., Altman, D. G., Gotzsche, P. C., Juni, P., Moher, D., Oxman, A. D., Savovic, J., Schulz, K. F., Weeks, L., Sterne, J. A. C., et al. (2011) · BMJ · doi:10.1136/bmj.d5928 · Cited by 33,817
Self-citationWhiting, P., Rutjes, A. W., Reitsma, J. B., Bossuyt, P. M., & Kleijnen, J. (2003) · BMC Medical Research Methodology · doi:10.1186/1471-2288-3-25 · Cited by 3,592
Self-citationThe Hazards of Scoring the Quality of Clinical Trials for Meta-analysis
Jüni, P. (1999) · JAMA · doi:10.1001/jama.282.11.1054 · Cited by 1,981
Empirical evidence of design-related bias in studies of diagnostic tests.
Lijmer, J. G. (1999) · JAMA · doi:10.1001/jama.282.11.1061 · Cited by 1,861 · cited 2×
“Studies enrolling participants with known disease and a control group without the condition may similarly exaggerate diagnostic accuracy (7, 11).”
BackgroundGuidance for Developers of Health Research Reporting Guidelines
Moher, D., Schulz, K. F., Simera, I., & Altman, D. G. (2010) · PLoS Medicine · doi:10.1371/journal.pmed.1000217 · Cited by 1,437
Systematic Reviews of Diagnostic Test Accuracy
Leeflang, M. M. G., Deeks, J. J., Gatsonis, C., & Bossuyt, P. M. M. (2008) · Annals of Internal Medicine · doi:10.7326/0003-4819-149-12-200812160-00008 · Cited by 1,124
Self-citationSources of Variation and Bias in Studies of Diagnostic Accuracy: A Systematic Review
Whiting, P., Rutjes, A. W. S., Reitsma, J. B., Glas, A. S., Bossuyt, P. M. M., & Kleijnen, J. (2004) · Annals of Internal Medicine · doi:10.7326/0003-4819-140-3-200402030-00010 · Cited by 798 · cited 4×
“The third review was an update on sources of bias and variation in diagnostic accuracy studies that included 101 studies (7).”
BackgroundInfluentialSelf-citationEvaluation of QUADAS, a tool for the quality assessment of diagnostic accuracy studies
Whiting, P. F., Weswood, M. E., Rutjes, A. W., Reitsma, J. B., Bossuyt, P. N., & Kleijnen, J. (2006) · BMC Medical Research Methodology · doi:10.1186/1471-2288-6-9 · Cited by 769
Self-citationLeeflang, M. M. G., Moons, K. G. M., Reitsma, J. B., & Zwinderman, A. H. (2008) · Clinical Chemistry · doi:10.1373/clinchem.2007.096032 · Cited by 346 · cited 1×
“Test performance is likely to be poorer in an independent sample of patients in whom the same threshold is used (12).”
BackgroundSelf-citationNo role for quality scores in systematic reviews of diagnostic accuracy studies
Whiting, P., Harbord, R., & Kleijnen, J. (2005) · BMC Medical Research Methodology · doi:10.1186/1471-2288-5-19 · Cited by 337
Self-citation
Cited by
Items 301–400 of 14,770
Rossini, G., Parrini, S., Castroflorio, T., Deregibus, A., & Debernardi, C. L. (2016) · American Journal of Orthodontics and Dentofacial Orthopedics · doi:10.1016/j.ajodo.2015.06.029 · Cited by 235
Pimenta-Melo, A. R., Monteiro-Soares, M., Libânio, D., & Dinis-Ribeiro, M. (2016) · European Journal of Gastroenterology & Hepatology · doi:10.1097/meg.0000000000000657 · Cited by 245
Chrysidis, S., Duftner, C., Dejaco, C., Schäfer, V. S., Ramiro, S., Carrara, G., Scirè, C. A., Hocevar, A., Diamantopoulos, A. P., Iagnocco, A., et al. (2018) · RMD Open · doi:10.1136/rmdopen-2017-000598 · Cited by 239
O’Connor, E. A., Perdue, L. A., Senger, C. A., Rushkin, M., Patnode, C. D., Bean, S. I., & Jonas, D. E. (2018) · JAMA · doi:10.1001/jama.2018.12086 · Cited by 249
The toe-brachial index in the diagnosis of peripheral arterial disease
Høyer, C., Sandermann, J., & Petersen, L. J. (2013) · Journal of Vascular Surgery · doi:10.1016/j.jvs.2013.03.044 · Cited by 237
St John, E. R., Al-Khudairi, R., Ashrafian, H., Athanasiou, T., Takats, Z., Hadjiminas, D. J., Darzi, A., & Leff, D. R. (2017) · Annals of Surgery · doi:10.1097/sla.0000000000001897 · Cited by 251
Benabbas, R., Hanna, M., Shah, J., & Sinert, R. (2017) · Academic Emergency Medicine · doi:10.1111/acem.13181 · Cited by 234
Diaphragm and Lung Ultrasound to Predict Weaning Outcome
Llamas-Álvarez, A. M., Tenza-Lozano, E. M., & Latour-Pérez, J. (2017) · Chest · doi:10.1016/j.chest.2017.08.028 · Cited by 243
Ospina, N. S., Al Nofal, A., Bancos, I., Javed, A., Benkhadra, K., Kapoor, E., Lteif, A. N., Natt, N., & Murad, M. H. (2016) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jc.2015-1700 · Cited by 247
Understanding the Direction of Bias in Studies of Diagnostic Test Accuracy
Kohn, M. A., Carpenter, C. R., & Newman, T. B. (2013) · Academic Emergency Medicine · doi:10.1111/acem.12255 · Cited by 241
Zhao, H., & Li, H. (2019) · European Journal of Radiology · doi:10.1016/j.ejrad.2019.01.006 · Cited by 243
Fernando, S. M., Tran, A., Cheng, W., Klompas, M., Kyeremanteng, K., Mehta, S., English, S. W., Muscedere, J., Cook, D. J., Torres, A., et al. (2020) · Intensive Care Medicine · doi:10.1007/s00134-020-06036-z · Cited by 231
Khanagar, S. B., Al-Ehaideb, A., Vishwanathaiah, S., Maganur, P. C., Patil, S., Naik, S., Baeshen, H. A., & Sarode, S. S. (2021) · Journal of Dental Sciences · doi:10.1016/j.jds.2020.05.022 · Cited by 219
Merriel, S. W. D., Pocock, L., Gilbert, E., Creavin, S., Walter, F. M., Spencer, A., & Hamilton, W. (2022) · BMC Medicine · doi:10.1186/s12916-021-02230-y · Cited by 214
Rapid, point-of-care antigen tests for diagnosis of SARS-CoV-2 infection
Dinnes, J., Sharma, P., Berhane, S., van Wyk, S. S., Nyaaba, N., Domen, J., Taylor, M., Cunningham, J., Davenport, C., Dittrich, S., et al. (2022) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd013705.pub3 · Cited by 225
Self-citationFarrah, K., Young, K., Tunis, M. C., & Zhao, L. (2019) · Systematic Reviews · doi:10.1186/s13643-019-1172-8 · Cited by 246
Hanna, G. B., Boshier, P. R., Markar, S. R., & Romano, A. (2019) · JAMA Oncology · doi:10.1001/jamaoncol.2018.2815 · Cited by 237
Xpert ® MTB/RIF assay for extrapulmonary tuberculosis and rifampicin resistance
Kohli, M., Schiller, I., Dendukuri, N., Dheda, K., Denkinger, C. M., Schumacher, S. G., & Steingart, K. R. (2018) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd012768.pub2 · Cited by 245
Germini, F., Noronha, N., Borg Debono, V., Abraham Philip, B., Pete, D., Navarro, T., Keepanasseril, A., Parpia, S., de Wit, K., & Iorio, A. (2022) · Journal of Medical Internet Research · doi:10.2196/30791 · Cited by 220
“The risk of bias was assessed using the Quality Assessment of Diagnostic Accuracy Studies, version 2, tool [10].”
Part 7: Neonatal resuscitation
Wyllie, J., Perlman, J. M., Kattwinkel, J., Wyckoff, M. H., Aziz, K., Guinsburg, R., Kim, H.-S., Liley, H. G., Mildenhall, L., Simon, W. M., et al. (2015) · Resuscitation · doi:10.1016/j.resuscitation.2015.07.045 · Cited by 237
Part 3: Adult basic life support and automated external defibrillation
Perkins, G. D., Travers, A. H., Berg, R. A., Castren, M., Considine, J., Escalante, R., Gazmuri, R. J., Koster, R. W., Lim, S. H., Nation, K. J., et al. (2015) · Resuscitation · doi:10.1016/j.resuscitation.2015.07.041 · Cited by 218
Diagnostic tests for autism spectrum disorder (ASD) in preschool children
Randall, M., Egberts, K. J., Samtani, A., Scholten, R. J., Hooft, L., Livingstone, N., Sterling-Levis, K., Woolfenden, S., & Williams, K. (2018) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd009044.pub2 · Cited by 216
Holl, D. C., Volovici, V., Dirven, C. M. F., Peul, W. C., van Kooten, F., Jellema, K., van der Gaag, N. A., Miah, I. P., Kho, K. H., den Hertog, H. M., et al. (2018) · World Neurosurgery · doi:10.1016/j.wneu.2018.05.037 · Cited by 228
Leeflang, M. M. G., Ang, C. W., Berkhout, J., Bijlmer, H. A., Van Bortel, W., Brandenburg, A. H., Van Burgel, N. D., Van Dam, A. P., Dessau, R. B., Fingerle, V., et al. (2016) · BMC Infectious Diseases · doi:10.1186/s12879-016-1468-4 · Cited by 230
Self-citationOrso, D., Paoli, I., Piani, T., Cilenti, F. L., Cristiani, L., & Guglielmo, N. (2020) · Journal of Intensive Care Medicine · doi:10.1177/0885066617752308 · Cited by 223
Does This Child Have Pneumonia?: The Rational Clinical Examination Systematic Review
Shah, S. N., Bachur, R. G., Simel, D. L., & Neuman, M. I. (2017) · JAMA · doi:10.1001/jama.2017.9039 · Cited by 231
Guerriero, S., Saba, L., Pascual, M. A., Ajossa, S., Rodriguez, I., Mais, V., & Alcazar, J. L. (2018) · Ultrasound in Obstetrics & Gynecology · doi:10.1002/uog.18961 · Cited by 228
The diagnosis of food allergy: a systematic review and meta‐analysis
Soares‐Weiser, K., Takwoingi, Y., Panesar, S. S., Muraro, A., Werfel, T., Hoffmann‐Sommergruber, K., Roberts, G., Halken, S., Poulsen, L., van Ree, R., et al. (2014) · Allergy · doi:10.1111/all.12333 · Cited by 235
Self-citationKnoll, T., Omar, M. I., Maclennan, S., Hernández, V., Canfield, S., Yuan, Y., Bruins, M., Marconi, L., Van Poppel, H., N’Dow, J., et al. (2018) · European Urology · doi:10.1016/j.eururo.2017.08.016 · Cited by 230
Liu, M., Okuhara, T., Chang, X., Shirabe, R., Nishiie, Y., Okada, H., & Kiuchi, T. (2024) · Journal of Medical Internet Research · doi:10.2196/60807 · Cited by 217
Niven, D. J., Gaudet, J. E., Laupland, K. B., Mrklas, K. J., Roberts, D. J., & Stelfox, H. T. (2015) · Annals of Internal Medicine · doi:10.7326/m15-1150 · Cited by 240
Accuracy of urea breath test in Helicobacter pylori infection: Meta-analysis
Ferwana, M. (2015) · World Journal of Gastroenterology · doi:10.3748/wjg.v21.i4.1305 · Cited by 228
Guerriero, S., Ajossa, S., Minguez, J. A., Jurado, M., Mais, V., Melis, G. B., & Alcazar, J. L. (2015) · Ultrasound in Obstetrics & Gynecology · doi:10.1002/uog.15667 · Cited by 237
Leonardi Dutra, K., Haas, L., Porporatti, A. L., Flores-Mir, C., Nascimento Santos, J., Mezzomo, L. A., Corrêa, M., & De Luca Canto, G. (2016) · Journal of Endodontics · doi:10.1016/j.joen.2015.12.015 · Cited by 219
El Shayeb, M., Topfer, L.-A., Stafinski, T., Pawluk, L., & Menon, D. (2014) · Canadian Medical Association Journal · doi:10.1503/cmaj.130952 · Cited by 237
Blood CEA levels for detecting recurrent colorectal cancer
Nicholson, B. D., Shinkins, B., Pathiraja, I., Roberts, N. W., James, T. J., Mallett, S., Perera, R., Primrose, J. N., & Mant, D. (2015) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd011134.pub2 · Cited by 226
Self-citationStruyf, T., Deeks, J. J., Dinnes, J., Takwoingi, Y., Davenport, C., Leeflang, M. M., Spijker, R., Hooft, L., Emperador, D., Domen, J., et al. (2021) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd013665.pub2 · Cited by 234
Self-citationKariyawasam, R. M., Julien, D. A., Jelinski, D. C., Larose, S. L., Rennert-May, E., Conly, J. M., Dingle, T. C., Chen, J. Z., Tyrrell, G. J., Ronksley, P. E., et al. (2022) · Antimicrobial Resistance & Infection Control · doi:10.1186/s13756-022-01085-z · Cited by 210
Lee, Y. S., Koo, K.-H., Kim, H. J., Tian, S., Kim, T.-Y., Maltenfort, M. G., & Chen, A. F. (2017) · Journal of Bone and Joint Surgery · doi:10.2106/jbjs.17.00123 · Cited by 223
British Society for Rheumatology guideline on diagnosis and treatment of giant cell arteritis
Mackie, S. L., Dejaco, C., Appenzeller, S., Camellino, D., Duftner, C., Gonzalez-Chiappe, S., Mahr, A., Mukhtyar, C., Reynolds, G., de Souza, A. W. S., et al. (2020) · Rheumatology · doi:10.1093/rheumatology/kez672 · Cited by 231
Silvester, J. A., Kurada, S., Szwajcer, A., Kelly, C. P., Leffler, D. A., & Duerksen, D. R. (2017) · Gastroenterology · doi:10.1053/j.gastro.2017.05.015 · Cited by 235
Smailagic, N., Vacante, M., Hyde, C., Martin, S., Ukoumunne, O., & Sachpekidis, C. (2015) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd010632.pub2 · Cited by 204
Treglia, G., Piccardo, A., Imperiale, A., Strobel, K., Kaufmann, P. A., Prior, J. O., & Giovanella, L. (2019) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-018-4123-z · Cited by 236
Zhu, W., He, W., Guo, L., Wang, X., & Hong, K. (2015) · Clinical Cardiology · doi:10.1002/clc.22435 · Cited by 224
Broyles, L. N., Luo, R., Boeras, D., & Vojnov, L. (2023) · The Lancet · doi:10.1016/s0140-6736(23)00877-2 · Cited by 218
Combination of the non-invasive tests for the diagnosis of endometriosis
Nisenblat, V., Prentice, L., Bossuyt, P. M., Farquhar, C., Hull, M. L., & Johnson, N. (2016) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd012281 · Cited by 224
Self-citationLeenen, J. P. L., Leerentveld, C., van Dijk, J. D., van Westreenen, H. L., Schoonhoven, L., & Patijn, G. A. (2020) · Journal of Medical Internet Research · doi:10.2196/18636 · Cited by 224
Saliva as a Candidate for COVID-19 Diagnostic Testing: A Meta-Analysis
Czumbel, L. M., Kiss, S., Farkas, N., Mandel, I., Hegyi, A., Nagy, Á., Lohinai, Z., Szakács, Z., Hegyi, P., Steward, M. C., et al. (2020) · Frontiers in Medicine · doi:10.3389/fmed.2020.00465 · Cited by 235
Borre, E., Goode, A., Raitz, G., Shah, B., Lowenstern, A., Chatterjee, R., Sharan, L., Allen LaPointe, N., Yapa, R., Davis, J., et al. (2018) · Thrombosis and Haemostasis · doi:10.1055/s-0038-1675400 · Cited by 229
A systematic review of biomarkers to detect active tuberculosis
MacLean, E., Broger, T., Yerlikaya, S., Fernandez-Carballo, B. L., Pai, M., & Denkinger, C. M. (2019) · Nature Microbiology · doi:10.1038/s41564-019-0380-2 · Cited by 220
Vanga, R. R., Tansel, A., Sidiq, S., El-Serag, H. B., & Othman, M. O. (2018) · Clinical Gastroenterology and Hepatology · doi:10.1016/j.cgh.2018.01.027 · Cited by 221
“We used the Quality Assessment of Diagnostic Accuracy Studies tool to assess the risk of bias in 4 domains regarding participant selection, index test, target condition, reference standard, and flow and timing.(24) Two authors (R.”
Galactomannan detection for invasive aspergillosis in immunocompromised patients
Leeflang, M. M., Debets-Ossenkopp, Y. J., Wang, J., Visser, C. E., Scholten, R. J., Hooft, L., Bijlmer, H. A., Reitsma, J. B., Zhang, M., Bossuyt, P. M., et al. (2015) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd007394.pub2 · Cited by 222
Self-citationZou, M., Tang, L., Zhao, S., Zhao, Z., Chen, L., Chen, P., Huang, Z., Li, J., Chen, L., & Fan, X. (2012) · PLoS ONE · doi:10.1371/journal.pone.0043347 · Cited by 226
Kwong, A. K. L., Fitzgerald, T. L., Doyle, L. W., Cheong, J. L. Y., & Spittle, A. J. (2018) · Developmental Medicine & Child Neurology · doi:10.1111/dmcn.13697 · Cited by 226
Montreal Cognitive Assessment for the diagnosis of Alzheimer’s disease and other dementias
Davis, D. H., Creavin, S. T., Yip, J. L., Noel-Storr, A. H., Brayne, C., & Cullum, S. (2015) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd010775.pub2 · Cited by 217
Utility of thromboelastography and/or thromboelastometry in adults with sepsis: a systematic review
Müller, M. C., Meijers, J. C., Vroom, M. B., & Juffermans, N. P. (2014) · Critical Care · doi:10.1186/cc13721 · Cited by 221
“We used the QUADAS-2 checklist to assess the quality of diagnostic studies [11,12].”
Eusebi, P., Giannandrea, D., Biscetti, L., Abraha, I., Chiasserini, D., Orso, M., Calabresi, P., & Parnetti, L. (2017) · Movement Disorders · doi:10.1002/mds.27110 · Cited by 220
“Quality Assessment We assessed the methodological quality of the selected studies using the QUADAS-2 tool.(24) The tool is composed of the following 4 domains: patient selection, index test, reference standard, flow and timing.”
MethodEvaluation of ChatGPT-generated medical responses: A systematic review and meta-analysis
Wei, Q., Yao, Z., Cui, Y., Wei, B., Jin, Z., & Xu, X. (2024) · Journal of Biomedical Informatics · doi:10.1016/j.jbi.2024.104620 · Cited by 201
Figueroa, C., Johnson, C., Ford, N., Sands, A., Dalal, S., Meurant, R., Prat, I., Hatzold, K., Urassa, W., & Baggaley, R. (2018) · The Lancet HIV · doi:10.1016/s2352-3018(18)30044-4 · Cited by 226
Fanti, S., Minozzi, S., Castellucci, P., Balduzzi, S., Herrmann, K., Krause, B. J., Oyen, W., & Chiti, A. (2016) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-015-3202-7 · Cited by 223
Rossi, A. C., & Prefumo, F. (2013) · Obstetrics & Gynecology · doi:10.1097/aog.0000000000000015 · Cited by 224
Diagnostic Accuracy of Computed Tomography–Derived Fractional Flow Reserve: A Systematic Review
Cook, C. M., Petraco, R., Shun-Shin, M. J., Ahmad, Y., Nijjer, S., Al-Lamee, R., Kikuta, Y., Shiono, Y., Mayet, J., Francis, D. P., et al. (2017) · JAMA Cardiology · doi:10.1001/jamacardio.2017.1314 · Cited by 218
Diagnostic accuracy of eFAST in the trauma patient: a systematic review and meta-analysis
Netherton, S., Milenkovic, V., Taylor, M., & Davis, P. J. (2019) · CJEM · doi:10.1017/cem.2019.381 · Cited by 207
Leruez-Ville, M., Chatzakis, C., Lilleri, D., Blazquez-Gamero, D., Alarcon, A., Bourgon, N., Foulon, I., Fourgeaud, J., Gonce, A., Jones, C. E., et al. (2024) · The Lancet Regional Health - Europe · doi:10.1016/j.lanepe.2024.100892 · Cited by 191
Visual Inspection for Caries Detection: A Systematic Review and Meta-analysis
Gimenez, T., Piovesan, C., Braga, M. M., Raggio, D. P., Deery, C., Ricketts, D. N., Ekstrand, K. R., & Mendes, F. M. (2015) · Journal of Dental Research · doi:10.1177/0022034515586763 · Cited by 203
Diagnosing Intracranial Aneurysms With MR Angiography: Systematic Review and Meta-Analysis
Sailer, A. M. H., Wagemans, B. A. J. M., Nelemans, P. J., de Graaf, R., & van Zwam, W. H. (2014) · Stroke · doi:10.1161/strokeaha.113.003133 · Cited by 215
Dinnes, J., Bancos, I., Ferrante di Ruffano, L., Chortis, V., Davenport, C., Bayliss, S., Sahdev, A., Guest, P., Fassnacht, M., Deeks, J. J., et al. (2016) · European Journal of Endocrinology · doi:10.1530/eje-16-0461 · Cited by 219
Self-citationViswanathan, M., Reddy, S., Berkman, N., Cullen, K., Middleton, J. C., Nicholson, W. K., & Kahwati, L. C. (2018) · JAMA · doi:10.1001/jama.2018.6537 · Cited by 206
Maynard-Smith, L., Larke, N., Peters, J. A., & Lawn, S. D. (2014) · BMC Infectious Diseases · doi:10.1186/s12879-014-0709-7 · Cited by 218
Kambeitz, J., Kambeitz-Ilankovic, L., Leucht, S., Wood, S., Davatzikos, C., Malchow, B., Falkai, P., & Koutsouleris, N. (2015) · Neuropsychopharmacology · doi:10.1038/npp.2015.22 · Cited by 216
Accuracy of 3-Dimensionally Printed Full-Arch Dental Models: A Systematic Review
Etemad-Shahidi, Y., Qallandar, O. B., Evenden, J., Alifui-Segbaya, F., & Ahmed, K. E. (2020) · Journal of Clinical Medicine · doi:10.3390/jcm9103357 · Cited by 206
Fernando, S. M., Tran, A., Cheng, W., Rochwerg, B., Taljaard, M., Kyeremanteng, K., English, S. W., Sekhon, M. S., Griesdale, D. E. G., Dowlatshahi, D., et al. (2019) · BMJ · doi:10.1136/bmj.l4225 · Cited by 214
Lees, R., Selvarajah, J., Fenton, C., Pendlebury, S. T., Langhorne, P., Stott, D. J., & Quinn, T. J. (2014) · Stroke · doi:10.1161/strokeaha.114.005842 · Cited by 206
Evangelista, L., Briganti, A., Fanti, S., Joniau, S., Reske, S., Schiavina, R., Stief, C., Thalmann, G. N., & Picchio, M. (2016) · European Urology · doi:10.1016/j.eururo.2016.01.029 · Cited by 217
Mocellin, S., & Pasquali, S. (2015) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd009944.pub2 · Cited by 215
Cross-Cultural Applicability of the Montreal Cognitive Assessment (MoCA): A Systematic Review
O’Driscoll, C., & Shaikh, M. (2017) · Journal of Alzheimer's Disease · doi:10.3233/jad-161042 · Cited by 209
The performance of anthropometric tools to determine obesity: a systematic review and meta-analysis
Sommer, I., Teufer, B., Szelag, M., Nussbaumer-Streit, B., Titscher, V., Klerings, I., & Gartlehner, G. (2020) · Scientific Reports · doi:10.1038/s41598-020-69498-7 · Cited by 192
Deep learning for cephalometric landmark detection: systematic review and meta-analysis
Schwendicke, F., Chaurasia, A., Arsiwala, L., Lee, J.-H., Elhennawy, K., Jost-Brinkmann, P.-G., Demarco, F., & Krois, J. (2021) · Clinical Oral Investigations · doi:10.1007/s00784-021-03990-w · Cited by 193
Yoon, J. H., Strand, F., Baltzer, P. A. T., Conant, E. F., Gilbert, F. J., Lehman, C. D., Morris, E. A., Mullen, L. A., Nishikawa, R. M., Sharma, N., et al. (2023) · Radiology · doi:10.1148/radiol.222639 · Cited by 198
“Study quality was assessed using Quality Assessment of Diagnostic Accuracy Studies 2 (QUADAS-2) (26) and QUADAS interpretations to reduce interobserver variability, while also managing workforce limitations (10,11).”
A Systematic Evaluation of Prevalence and Diagnostic Accuracy of Sacroiliac Joint Interventions
Simopoulos, T. T. (2012) · Pain Physician · doi:10.36076/ppj.2012/15/e305 · Cited by 220
Simons, J. M., van Nijnatten, T. J. A., van der Pol, C. C., Luiten, E. J. T., Koppert, L. B., & Smidt, M. L. (2019) · Annals of Surgery · doi:10.1097/sla.0000000000003075 · Cited by 196
Speyer, R., Cordier, R., Farneti, D., Nascimento, W., Pilz, W., Verin, E., Walshe, M., & Woisard, V. (2022) · Dysphagia · doi:10.1007/s00455-021-10283-7 · Cited by 194
Kohli, M., Schiller, I., Dendukuri, N., Yao, M., Dheda, K., Denkinger, C. M., Schumacher, S. G., & Steingart, K. R. (2021) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd012768.pub3 · Cited by 215
Khanna, D., Gladue, H., Channick, R., Chung, L., Distler, O., Furst, D. E., Hachulla, E., Humbert, M., Langleben, D., Mathai, S. C., et al. (2013) · Arthritis & Rheumatism · doi:10.1002/art.38172 · Cited by 210
Ritchie, C., Smailagic, N., Noel-Storr, A. H., Ukoumunne, O., Ladds, E. C., & Martin, S. (2017) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd010803.pub2 · Cited by 208
Sharifov, O. F., Schiros, C. G., Aban, I., Denney, T. S., & Gupta, H. (2016) · Journal of the American Heart Association · doi:10.1161/jaha.115.002530 · Cited by 209
Systematic reviews of the literature: an introduction to current methods
Brignardello‐Petersen, R., Santesso, N. A., & Guyatt, G. H. (2024) · American Journal of Epidemiology · doi:10.1093/aje/kwae232 · Cited by 260
“…facilitate this assessment,such as the Risk of Bias 2.0 tool 27 for randomized controlled trials, the Risk Of Bias in Nonrandomized studies of Interventions (ROBINS-I), 28 the Quality Assessment of Diagnostic Accuracy Studies (QUADAS)- 2 tool, 29 and the Quality in Prognosis Studies (QUIPS) tool.”
InfluentialSenaratna, C. V., Perret, J. L., Matheson, M. C., Lodge, C. J., Lowe, A. J., Cassim, R., Russell, M. A., Burgess, J. A., Hamilton, G. S., & Dharmage, S. C. (2017) · Sleep Medicine Reviews · doi:10.1016/j.smrv.2017.04.001 · Cited by 214
Slattery, S. A., Niaz, O., Aziz, Q., Ford, A. C., & Farmer, A. D. (2015) · Alimentary Pharmacology & Therapeutics · doi:10.1111/apt.13227 · Cited by 214
van Hanegem, N., Prins, M. M. C., Bongers, M. Y., Opmeer, B. C., Sahota, D. S., Mol, B. W. J., & Timmermans, A. (2016) · European Journal of Obstetrics & Gynecology and Reproductive Biology · doi:10.1016/j.ejogrb.2015.12.008 · Cited by 214
Lombardi, G., Crescioli, G., Cavedo, E., Lucenteforte, E., Casazza, G., Bellatorre, A.-G., Lista, C., Costantino, G., Frisoni, G., Virgili, G., et al. (2020) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd009628.pub2 · Cited by 214
Geijer, H., & Breimer, L. H. (2013) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-013-2482-z · Cited by 212
Hanna, R. F., Miloushev, V. Z., Tang, A., Finklestone, L. A., Brejt, S. Z., Sandhu, R. S., Santillan, C. S., Wolfson, T., Gamst, A., & Sirlin, C. B. (2016) · Abdominal Radiology · doi:10.1007/s00261-015-0592-8 · Cited by 210
Fields, J. M., Davis, J., Girson, L., Au, A., Potts, J., Morgan, C. J., Vetter, I., & Riesenberg, L. A. (2017) · Journal of the American Society of Echocardiography · doi:10.1016/j.echo.2017.03.004 · Cited by 203
Deep learning for wireless capsule endoscopy: a systematic review and meta-analysis
Soffer, S., Klang, E., Shimon, O., Nachmias, N., Eliakim, R., Ben-Horin, S., Kopylov, U., & Barash, Y. (2020) · Gastrointestinal Endoscopy · doi:10.1016/j.gie.2020.04.039 · Cited by 207
Liu, B., Gao, S., & Li, S. (2017) · Gynecologic and Obstetric Investigation · doi:10.1159/000456006 · Cited by 212
Han, S., Suh, C. H., Woo, S., Kim, Y. J., & Lee, J. J. (2019) · Journal of Nuclear Medicine · doi:10.2967/jnumed.118.211706 · Cited by 205
The diagnostic and triage accuracy of digital and online symptom checker tools: a systematic review
Wallace, W., Chan, C., Chidambaram, S., Hanna, L., Iqbal, F. M., Acharya, A., Normahani, P., Ashrafian, H., Markar, S. R., Sounderajah, V., et al. (2022) · npj Digital Medicine · doi:10.1038/s41746-022-00667-w · Cited by 186
Luo, J., Shen, L., & Zheng, D. (2014) · Scientific Reports · doi:10.1038/srep06269 · Cited by 212
Webb, R. C., Howard, R. S., Stojadinovic, A., Gaitonde, D. Y., Wallace, M. K., Ahmed, J., & Burch, H. B. (2012) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jc.2012-1533 · Cited by 213
Metadata
- Authors
- Whiting, P. F., Rutjes, A. W. S., Westwood, M. E., Mallett, S., Deeks, J. J., Reitsma, J. B., Leeflang, M. M. G., Sterne, J. A. C., Bossuyt, P. M. M., & the QUADAS-2 Group*
- Affiliations
- University of Bern (CH)
- Corresponding author
- Whiting, Penny F.
- ORCID
- Venue
- Annals of Internal Medicine
- Publisher
- American College of Physicians
- Published
- 2011-10-18
- Volume
- 155
- Issue
- 8
- Pages
- 529-536
- ISSN
- 0003-4819 (ISSN-L)
- 1539-3704
- OpenAlex
- W2107638293
- Semantic Scholar
- 8a5d0b5a9271ea14bcb8479bc32d3844a80655b9
- Cited by
- 14,199
- References
- 18
- Citations by year
- 2026: 1484 · 2025: 1569 · 2024: 1524 · 2023: 1305 · 2022: 1420 · 2021: 1514 · 2020: 1245 · 2019: 955 · 2018: 767 · 2017: 637 · 2016: 580 · 2015: 528 · 2014: 363 · 2013: 217 · 2012: 75
- FWCI
- 224.36
- Type
- journal article
- Language
- en
- Open access
- green
- hdl.handle.net
- Licence
- cc-by
- www.acpjournals.org/journal/aim/text-and-data-mining (tdm)
- Locations
- Annals of Internal Medicine (publishedVersion)
- PubMed (publishedVersion)
- Pure Amsterdam UMC (publishedVersion)
- Data Archiving and Networked Services (DANS) (submittedVersion)
- Florence Research (University of Florence) (submittedVersion)
- IRIS UNIMORE (University of Modena and Reggio Emilia) (submittedVersion, cc-by)
- University of Birmingham Research Portal (University of Birmingham) (submittedVersion)
- Bristol Research (University of Bristol) (submittedVersion)
- Funders
- Cancer Research UK
- Topics
- Social Sciences › Decision Sciences › Statistics, Probability and Uncertainty › Meta-analysis and systematic reviews
- Physical Sciences › Mathematics › Statistics and Probability › Statistical Methods in Epidemiology
- Health Sciences › Medicine › Public Health, Environmental and Occupational Health › Clinical practice guidelines implementation
- Keywords
- QUADAS-2, diagnostic accuracy studies, quality assessment, risk of bias, applicability, patient selection, index tests, reference materials, flowcharts, systematic reviews
- MeSH terms
- Diagnosis, Humans, Quality Control, Surveys and Questionnaires, Reference Standards, Review Literature as Topic, Time Factors, Bias, Patient Selection, Evidence-Based Medicine
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
A language model drew the claims from the paper on 2026-11-23, under version 3 of the claim definition (model deepseek-v4.1-flash, prompt extract-v3).
A second model labelled each claim on 2026-11-23 (model jev-1.13-20260917, definition revision gold-guideline-v0.2).
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.