Comparative Effectiveness and Safety of Methods of Insulin Delivery and Glucose Monitoring for Diabetes Mellitus: A Systematic Review and Meta-analysis
Open accessThe DOI matches its Crossref record; 75 of the 75 references it cites were found in a registry or an index.
Abstract
BACKGROUND: Patients with diabetes mellitus need information about the effectiveness of innovations in insulin delivery and glucose monitoring. PURPOSE: To review how intensive insulin therapy (multiple daily injections [MDI] vs. rapid-acting analogue-based continuous subcutaneous insulin infusion [CSII]) or method of monitoring (self-monitoring of blood glucose [SMBG] vs. real-time continuous glucose monitoring [rt-CGM]) affects outcomes in types 1 and 2 diabetes mellitus. DATA SOURCES: MEDLINE, EMBASE, and the Cochrane Central Register of Controlled Trials through February 2012 without language restrictions. STUDY SELECTION: 33 randomized, controlled trials in children or adults that compared CSII with MDI (n=19), rt-CGM with SMBG (n=10), or sensor-augmented insulin pump use with MDI and SMBG (n=4). DATA EXTRACTION: 2 reviewers independently evaluated studies for eligibility and quality and serially abstracted data. DATA SYNTHESIS: In randomized, controlled trials, MDI and CSII showed similar effects on hemoglobin A1c (HbA1c) levels and severe hypoglycemia in children or adults with type 1 diabetes mellitus and adults with type 2 diabetes mellitus. In adults with type 1 diabetes mellitus, HbA1c levels decreased more with CSII than with MDI, but 1 study heavily influenced these results. Compared with SMBG, rt-CGM achieved a lower HbA1c level (between-group difference of change, 0.26% [95% CI, 0.33% to 0.19%]) without any difference in severe hypoglycemia. Sensor-augmented insulin pump use decreased HbA1c levels more than MDI and SMBG did in persons with type 1 diabetes mellitus (between-group difference of change, 0.68% [CI, 0.81% to 0.54%]). Little evidence was available on other outcomes. LIMITATION: Many studies were small, of short duration, and limited to white persons with type 1 diabetes mellitus. CONCLUSION: Continuous subcutaneous insulin infusion and MDI have similar effects on glycemic control and hypoglycemia, except CSII has a favorable effect on glycemic control in adults with type 1 diabetes mellitus. For glycemic control, rt-CGM is superior to SMBG and sensor-augmented insulin pumps are superior to MDI and SMBG without increasing the risk for hypoglycemia. PRIMARY FUNDING SOURCE: Agency for Healthcare Research and Quality.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Rates and the clinical impact of hypoglycemia are frequently underestimated,1108”
From American Association of Clinical Endocrinology Clinical Practice Guideline: Developing a Diabetes Mellitus Comprehensive Care Plan-2022 Update. (2022) · cites this paper as [1108]
In the citing paper
“The frequency of hypoglycemia increases with intensive insulin targets, use of SUs, decreased caloric intake, delayed meals, exercise, alcohol consumption, CKD, T2D duration, and cognitive impairment.1108”
From American Association of Clinical Endocrinology Clinical Practice Guideline: Developing a Diabetes Mellitus Comprehensive Care Plan-2022 Update. (2022) · cites this paper as [1108]
In the citing paper
“but about 7% to 15% of insulin-treated persons with T2D experience at least 1 episode of hypoglycemia per year,1109 and 1% to 2% have severe hypoglycemia.1106,1108”
From American Association of Clinical Endocrinology Clinical Practice Guideline: Developing a Diabetes Mellitus Comprehensive Care Plan-2022 Update. (2022) · cites this paper as [1108]
In the citing paper
“Hyperinsulinemia, increased alcohol intake, starvation, and organ failure may be aggravating factors.1108,1200,1201”
From American Association of Clinical Endocrinology Clinical Practice Guideline: Developing a Diabetes Mellitus Comprehensive Care Plan-2022 Update. (2022) · cites this paper as [1108]
In the citing paper
“In persons with DM, iatrogenic hypoglycemia stems from an imbalance among insulin and/or insulinogenic (eg, SUs, glinides) therapy and food intake, physical activity, organ function (gluconeogenesis), and counter-regulation with glucagon and/or epinephrine (hypoglycemia-associated autonomic failure).”
From American Association of Clinical Endocrinology Clinical Practice Guideline: Developing a Diabetes Mellitus Comprehensive Care Plan-2022 Update. (2022) · cites this paper as [1108]
6 more claims about this paper
Create a free account to see every claim other papers make about this one.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Preferred Reporting Items for Systematic Reviews and Meta-Analyses: the PRISMA statement
Moher, D., Liberati, A., Tetzlaff, J., Altman, D. G., & for the PRISMA Group (2009) · BMJ · doi:10.1136/bmj.b2535 · Cited by 83,823
Measuring inconsistency in meta-analyses
Higgins, J. P. T., Thompson, S. G., Deeks, J. J., & Altman, D. G. (2003) · BMJ · doi:10.1136/bmj.327.7414.557 · Cited by 63,139
Preferred reporting items for systematic reviews and meta-analyses: the PRISMA Statement.
(2009) · PubMed Central · Cited by 44,859
Meta-analysis in clinical trials
DerSimonian, R., & Laird, N. (1986) · Controlled Clinical Trials · doi:10.1016/0197-2456(86)90046-2 · Cited by 39,552
(1993) · New England Journal of Medicine · doi:10.1056/nejm199309303291401 · Cited by 24,667
Preferred Reporting Items for Systematic Reviews and Meta-Analyses: The PRISMA Statement
Moher, D., Liberati, A., Tetzlaff, J., & Altman, D. G. (2009) · Journal of Clinical Epidemiology · doi:10.1016/j.jclinepi.2009.06.005 · Cited by 19,575
Reduction in the incidence of type 2 diabetes with lifestyle intervention or metformin
(2002) · New England Journal of Medicine · doi:10.1056/nejmoa012512 · Cited by 19,011
Turner, R. C., Fox, C., Matthews, McElroy, H. H., Cull, C. A., Holman, R. R., Neil, P., Hadden, D. R., Wright, D., Manley, E., et al. (1998) · The Lancet · Cited by 8,419
Downs, S. H., & Black, N. (1998) · Journal of Epidemiology and Community Health · doi:10.1136/jech.52.6.377 · Cited by 8,252
Research works printed but not linked: 2
- 20587584N Engl J Med. 363N Engl J Med. 2010;363:383-4. [PMID: 20587584]
- Diabetes Prevention Program Research Group. Reduction in domized treat-to-target study. W C Knowler, E Barrett-Connor, S E Fowler, R F Hamman, J M Lachin, E A Walker, 18715214Diabetes Technol Ther. 10Knowler WC, Barrett-Connor E, Fowler SE, Hamman RF, Lachin JM, Walker EA, et al; Diabetes Prevention Program Research Group. Reduction in domized treat-to-target study. Diabetes Technol Ther. 2008;10:377-83. [PMID: 18715214]
Cited by
Items 401–492 of 492
Alabdulkarim, H. A., Al-Shraim, M., Motahari-Nezhad, H., Fgaier, M., Péntek, M., Gulàcsi, L., Aldahash, R., & Zrubka, Z. (2026) · Journal of Diabetes Science and Technology · doi:10.1177/19322968261445111 · Cited by 1
Advances in diabetes technology: clinical implications, limitations, and future perspectives
Apostolopoulou, M., & Effraimidis, G. (2026) · HORMONES · doi:10.1007/s42000-026-00797-w · Cited by 2
Real-Time Continuous Glucose Monitoring in Adult Outpatients
Bonomo, M. A., Grassi, G., Bartolo, P. D., & Maran, A. (2014) · Frontiers in diabetes · doi:10.1159/000363482 · Cited by 1
Soliman, A. T., Sanctis, V. D., Yassin, M. A., & Elalaily, R. (2014) · Advances in Diabetes and Metabolism · doi:10.13189/adm.2014.020201 · Cited by 2
¿De qué nos sirve evaluar las tendencias del perfil glucémico ambulatorio?
Izquierdo, E. S. (2014) · Avances en Diabetología · doi:10.1016/j.avdiab.2014.06.002 · Cited by 3
mHealth Environments for Chronic Disease Management
Georga, E. I., Papadopoulos, A. N., & Fotiadis, D. I. (2015) · Advances in medical diagnosis, treatment, and care (AMDTC) book series · doi:10.4018/978-1-4666-8828-5.ch024 · Cited by 2
Štechová, K., Vaniš, M., Tuháčková, M., Urbaniec, K., & Kvapil, M. (2018) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2018.0095 · Cited by 2
New Paradigm of Personalized Glycemic Control Using Glucose Temporal Density Histograms
Trahtemberg, U., Hallas, T., Segman, Y., Sheiman, E., Shasha, M., Nissim, K., & Segman, Y. J. (2019) · Journal of Diabetes Science and Technology · doi:10.1177/1932296818821423 · Cited by 1
Treatment of Type 1 Diabetes Mellitus in Adults
Retnakaran, R. R., & Zinman, B. (2015) · Elsevier eBooks · doi:10.1016/b978-0-323-18907-1.00044-5 · Cited by 1
Control neuro-fuzzy para páncreas artificial: desarrollo y validación in-silico
Ríos, Y. Y., García-Rodríguez, J. A., Sanchez, E. N., Alanís, A. Y., Ruiz-Velazquez, E., & Pardo, A. (2020) · Revista Iberoamericana de Automática e Informática Industrial RIAI · doi:10.4995/riai.2020.13035 · Cited by 2
Gastelum, A. A., Maraqa, S. A. R. A., Lavenant, W. M., Khan, A., McMahon, R. S., Latif, A., & Townley, T. A. (2021) · Journal of General Internal Medicine · doi:10.1007/s11606-021-06886-3 · Cited by 1
Real-World Analysis of Therapeutic Outcome in Type 1 Diabetes Mellitus at a Tertiary Care Center
Kietaibl, A.-T., Riedl, M., & Bozkurt, L. (2021) · Diabetes & Metabolism Journal · doi:10.4093/dmj.2020.0267 · Cited by 2
Principles of Diabetes Care and Lifestyle Modification
Moon, M. K. (2021) · Stroke revisited · doi:10.1007/978-981-16-5123-6_8 · Cited by 3
Putula, E., Hannula, P. M., Huhtala, H., & Metso, S. (2022) · Diabetes Epidemiology and Management · doi:10.1016/j.deman.2022.100072 · Cited by 1
Cho, S., Vigers, T., Pyle, L. L., Franklin, A. R. K., Sopfe, J., Jeney, F., & Forlenza, G. P. (2022) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2022.0246 · Cited by 1
Alkhatieb, M. T., Aljehani, K. M., Alkhalifah, H. A., Alghamdi, N. S., Almaghrabi, A. S., Alqarni, B. B., & Alzahrani, A. Y. (2023) · Cureus · doi:10.7759/cureus.39796 · Cited by 1
“Similar results were reported in two previous metaanalyses, in which CGM was shown to be the best glucose monitoring method for lowering HbA1c levels [17,18].”
ResultKiran, S., Nagarajappa, V. H., Sathyanarayana, S. O., Hegde, A., & Raghupathy, P. (2023) · Indian Journal of Endocrinology and Metabolism · doi:10.4103/ijem.ijem_376_22 · Cited by 1
Orbell, S. L., Codario, R. A., Zupa, M. F., & Estock, J. L. (2024) · Journal of Diabetes Science and Technology · doi:10.1177/19322968241254521 · Cited by 2
Franceschi, R., Mozzillo, E., Candia, F. D., Fanti, S., Maines, E., Guarnieri, C., Maffeis, C., Ros, A. D., Piccoli, E., Pertile, R., et al. (2025) · Diabetes Technology and Obesity Medicine · doi:10.1089/dtom.2025.0022 · Cited by 3
Rabbone, I., Frontino, G., & Bonfanti, R. (2014) · Frontiers in diabetes · doi:10.1159/000363488 · Cited by 1
Study on mid-IR spectroscopy on whole blood samples for human glucose quantification applications
Romo-Cárdenas, G. S., Sánchez-López, J. D. D., Cosío-León, M. D. L. Á., Luque, P. A., Gómez-Gutiérrez, C. M., Hipólito, J. I. N., Jiménez–Cruz, A., Camacho-López, S., & Vázquez-Briseño, M. (2018) · Infrared Sensors, Devices, and Applications · doi:10.1117/12.2320866 · Cited by 1
Reznik, Y., & Deberles, E. (2019) · Springer eBooks · doi:10.1007/978-3-319-98119-2_3 · Cited by 2
Development of physiological metabolic models in diabetes based on data mining techniques
Georga, E. I. (2019) · University of Ioannina · doi:10.26268/heal.uoi.1420 · Cited by 1
Diabetes in pregnancy: current ways of treatment
Bartášková, D. (2019) · Vnitřní lékařství · doi:10.36290/vnl.2019.044 · Cited by 2
Siddig, A., Bui, T. D. M. P., Readon, D. R., M., V. A., Bailes, Z., Hefner, J., Gillig, A., Singh, D., & Yeboah, K. G. (2020) · Journal of Drug Research and Development · doi:10.16966/2470-1009.154
Moreno-Fernández, J., & Chico, A. I. (2016) · Endocrinología y Nutrición (English Edition) · doi:10.1016/j.endoen.2016.09.014 · Cited by 1
Pecoli, P. F. G., Rosa, A. D. S., Gabbay, M. A. L., & Dib, S. A. (2023) · Healthcare · doi:10.3390/healthcare11162300 · Cited by 1
“The literature reveals that CSII and multiple daily injections have similar effects on glycemic control and hypoglycemia, with CSII having a favorable effect on glycemic control in adults with type 1 diabetes [42].”
BackgroundAmbler, G. R., Cameron, F. J., Joshi, K., & Wherrett, D. K. (2019) · Wiley eBooks · doi:10.1002/9781119152712.ch15 · Cited by 1
Glycemic treatment of diabetes mellitus
Kaur, H., & Weinstock, R. S. (2014) · Wiley eBooks · doi:10.1002/9781118887837.ch4 · Cited by 1
Liu, S. (2014) · Scholarship@Western (Western University)
Kontinuierliche Glucosemessung bei erwachsenen Typ-I-Diabetes-Patienten
Heinemann, L., & Siegmund, T. (2013) · Der Diabetologe · doi:10.1007/s11428-013-1121-4 · Cited by 1
High-Priority Research Needs for Insulin Delivery and Glucose Monitoring Methods
Yeh, H., Lau, B. D., Golden, S. H., Donner, T. W., Brown, T. T., & Bass, E. B. (2013) · Journal of Diabetes Science and Technology · doi:10.1177/193229681300700628
Self-citationRíos, P., Casado, N., Matas, O., Martín, M., Iglesias, S., Giménez, M., Vinagre, I., & Conget, I. (2014) · Avances en Diabetología · doi:10.1016/j.avdiab.2014.10.004
Continuous subcutaneous insulin infusion versus multiple dose insulin
Gupta, Y., & Kalra, S. (2014) · Sri Lanka Journal of Diabetes Endocrinology and Metabolism · doi:10.4038/sjdem.v4i1.7249
“Type 1 DM (Children) HbA1c Meta-analysis on 7 RCTs (16 or more weeks of followup), compared MDI with CSII in children and adolescents with type 1 diabetes mellitus (1).”
BackgroundMethodInfluentialGrunberger, G., Abelseth, J. M., Bailey, T. S., Bode, B. W., Handelsman, Y., Hellman, R., Lane, W. S., Raskin, P., Tamborlane, W. V., & Rothermel, C. (2014)
Is an Indispensable Tool in Evidence Synthesis
Cefalu, W. T. (2013)
Clinical management of type 1 diabetes
Iqbal, A., & Heller, S. R. (2015) · Wiley eBooks · doi:10.1002/9781119121725.ch8
New Technology for Type 1 Diabetes
Yang, Y., & Cho, J. (2015) · Journal of Korean Diabetes · doi:10.4093/jkd.2015.16.2.123
“최근의 일련의 연구들에서 연속 혈당 측정 (continuous glucose monitoring, CGMS)은 고전적인 방 법에 비해 당화혈색소 강하효과를 보여주었다[9-11].”
Qualidade de vida e satisfação com o tratamento com bomba perfusora de Insulina
Sofia, A. (2013) · Portuguese National Funding Agency for Science, Research and Technology (RCAAP Project by FCT) · doi:10.34626/j7k4-x196
Intensive Insulin Therapy in Type 1 Diabetes
Han, K. A. (2015) · Journal of Korean Diabetes · doi:10.4093/jkd.2015.16.2.108
“인슐린 펌프와 인슐린 다회 주사요법을 비교한 몇 가지 연구에서 인슐린 펌프로 치료하였을 때 당화혈색소를 저하 가 더 뚜렷하였으나, 저혈당과 심각한 저혈당의 빈도는 두 군 사이에 의미 있는 차이가 없었다고 보고하였다[4-7].”
Kontinuierliche Glukosemessung im Alltag
Jecht, M. (2016) · Der Diabetologe · doi:10.1007/s11428-015-0056-3
“In mehreren Untersuchung ist diese Therapieform als effektiv in der Blutzuckereinstellung beschrieben worden, ohne dass es zu einem Anstieg von Hypoglykämien gekommen ist [1].”
BackgroundInsulin pumps: Great devices, but you still have to press the button
Nasr, C. E. (2015) · Cleveland Clinic Journal of Medicine · doi:10.3949/ccjm.82a.15047
Phase 3 Trial of Transplantation of Human Islets in Type 1 Diabetes Complicated by Severe
Hering, B. J., Clarke, W. R., Bridges, N. D., Eggerman, T. L., Alejandro, R., Bellin, M. D., Chaloner, K. M., Czarniecki, C. W., Goldstein, J., Hunsicker, L. G., et al. (2016)
Romo-Cárdenas, G. S., Sanchez-Lopez, J. D., Hipólito, J. I. N., Cosío-León, M. D. L. Á., Luque, P. A., & Vázquez-Briseño, M. (2016) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.2235805
“Several studies have shown that blood glucose monitoring offers information related with the possible increase or decrease of the blood glucose and enables any decision taking concerning the treatment of patients [2-4].”
BackgroundClosed Loop Systems In Type 1 Diabetes – A Dream That Might Soon Come True?
Guja, C. (2015) · Romanian Journal of Diabetes Nutrition and Metabolic Diseases · doi:10.1515/rjdnmd-2015-0014
Regular Evaluation for Patients with Diabetes Mellitus
Koo, B. K. (2016) · Journal of Korean Diabetes · doi:10.4093/jkd.2016.17.4.238
Supporting patients with type 1 diabetes
Phillips, A. (2017) · Practice Nursing · doi:10.12968/pnur.2017.28.1.28
Biester, T., & Wizemann, E. (2017) · Diabetologie und Stoffwechsel · doi:10.1055/s-0043-100389 · Cited by 1
Aristizábal, N., Ramírez, Á., Hincapié-García, J. A., Laiton, E., Aristizábal, C., Cuesta, D., Monsalve, C., Hincapié, G., Zapata, E., Abad, V., et al. (2015) · Endocrinología y Nutrición (English Edition) · doi:10.1016/j.endoen.2015.11.006
Continuous Subcutaneous Insulin Infusion for Adults with Type 1 Diabetes Mellitus
Shamliyan, T., & Lee, C. J. (2017) · The American Journal of Medicine · doi:10.1016/j.amjmed.2017.03.058 · Cited by 1
Comparative Effectiveness Research: Are The Methods Being Used Correctly?
Andrade, P., Dilla, T., & Sacristán, J. A. (2017) · Health Economics & Outcome Research Open Access · doi:10.4172/2573-4520.1000132 · Cited by 1
Lipscombe, L. L. (2017) · Annals of Internal Medicine · doi:10.7326/acpjc-2017-167-4-015
Gomes, M. B., & Negrato, C. A. (2017) · Diabetes Research and Clinical Practice · doi:10.1016/j.diabres.2017.09.003
Wizemann, E., & Biester, T. (2018) · Diabetes aktuell · doi:10.1055/a-0618-4826
Lifestyle intervention strategies for diabetes management
Tay, J., & Tay, J. (2016) · Adelaide Research & Scholarship (AR&S) (University of Adelaide) · doi:10.25909/5b63b9ac0685f
Part I: Continuous glucose monitoring systems
Moorman, J. M. (2020) · JACCP JOURNAL OF THE AMERICAN COLLEGE OF CLINICAL PHARMACY · doi:10.1002/jac5.1260
Estrategia terapéutica en el paciente diabético (III). Insulinoterapia
Ocaña, P. G., Cobos-Palacios, L., Muriel, C. C., & Jansen‐Chaparro, S. (2020) · Medicine - Programa de Formación Médica Continuada Acreditado · doi:10.1016/j.med.2020.09.021 · Cited by 2
Guiding Diabetic Therapy for Children and Adolescents with Type I Diabetes
Zang, S. M., & Arikian, V. (2019) · Journal of Comprehensive Nursing Research and Care · doi:10.33790/jcnrc1100153
Botero, J. F., Vásquez, L. M., Blanco, V. M., Cuesta, D., Rincón, A. R., Bedoya, J., & Palacio, A. (2021) · Endocrinología Diabetes y Nutrición (English ed ) · doi:10.1016/j.endien.2021.12.002 · Cited by 3
mHealth Environments for Chronic Disease Management
Georga, E. I., Papadopoulos, A. N., & Fotiadis, D. I. (2017) · IGI Global eBooks · doi:10.4018/978-1-5225-2237-9.ch038
mHealth Environments for Chronic Disease Management
Georga, E. I., Papadopoulos, A. N., & Fotiadis, D. I. (2018) · IGI Global eBooks · doi:10.4018/978-1-5225-6915-2.ch030
Maltoni, G., & Zucchini, S. (2016) · Springer eBooks · doi:10.1007/978-3-319-40242-0_13 · Cited by 1
Successes and Disappointments with Clinical Islet Transplantation
Cravedi, P., Ruggenenti, P. L., & Remuzzi, G. (2014) · Springer eBooks · doi:10.1007/978-94-007-6686-0_23
Nabors, L. (2016) · Springer eBooks · doi:10.1007/978-3-319-31117-3_3
Lu, G., Wang, M., Fox, T., Jiang, P., & Jiang, F. (2022) · Journal of Shanghai Jiaotong University (Science) · doi:10.1007/s12204-022-2439-0
Diabetestechnologie bei Kindern und Jugendlichen mit Diabetes mellitus Typ 1
Rami-Merhar, B. M. (2022) · Die Diabetologie · doi:10.1007/s11428-022-00975-5
Esteban, S. A. C., Ortiz, J. F. S., & Calderón-Benavides, L. (2023) · REVISTA COLOMBIANA DE TECNOLOGIAS DE AVANZADA · doi:10.24054/rcta.v1i39.1378 · Cited by 3
Iqbal, A., Chow, E., Jones, T. W., & Heller, S. R. (2024) · Wiley eBooks · doi:10.1002/9781119697473.ch40
Endocrine Drugs of Significance in Dentistry
Jeske, A. H. (2024) · Springer eBooks · doi:10.1007/978-3-031-53954-1_8
Insulin Pump Therapy Advantages and Disadvantages
(2024) · American Diabetes Association eBooks · doi:10.2337/9781580408363.ch01
(2024) · American Diabetes Association eBooks · doi:10.2337/9781580408363.ch05
Objetivos del tratamiento de la diabetes mellitus tipo 1
Cebada, A. B., da Silva, J. K. H., Escobar-Morreale, H. F., & Chávez, L. N. (2024) · Medicine - Programa de Formación Médica Continuada Acreditado · doi:10.1016/j.med.2024.10.002 · Cited by 2
Tecnología aplicada a la diabetes
Cebada, A. B., Silva, J. B. Q., Escobar-Morreale, H. F., & Chávez, L. N. (2024) · Medicine - Programa de Formación Médica Continuada Acreditado · doi:10.1016/j.med.2024.10.004
Impacto del inicio de la monitorización flash de glucosa en pacientes adultos con diabetes tipo 1
Sahagún, R. J. (2024) · UVaDOC UVaDOC University of Valladolid Documentary Repository (University of Valladolid) · doi:10.35376/10324/72390
Selecting Patients for Pumps and Continuous Glucose Monitoring: Who, Why, and Why Not?
Vincent, L., & Edelman, S. V. (2019) · doi:10.2337/9781580406932.part1_ch06
Alkhatib, O., Altaf, K., Khan, A., Whelan, P., Dunne, D., Raraty, M. G. T., Mann, K., Ghaneh, P., Halloran, C. M., Szatmary, P., et al. (2025) · HPB · doi:10.1016/j.hpb.2025.08.009
Pharmacologic Therapy for Type 2 Diabetes
(2025) · American Diabetes Association eBooks · doi:10.2337/9781580408462-ch04
Pharmacologic Therapy for Type 1 Diabetes
(2025) · American Diabetes Association eBooks · doi:10.2337/9781580408462-ch01
Management of Acute and Recurrent Hypoglycaemia
McCrimmon, R. J. (2013) · Wiley eBooks · doi:10.1002/9781118695432.ch8
Chua, A. Y., & Villa, M. L. (2018) · Philippine Journal of Internal Medicine · doi:10.65564/pjim.e77e273ac5
Glycemic management in adults with type 1 diabetes
Koliaki, C. C., & Liatis, S. (2026) · Elsevier eBooks · doi:10.1016/b978-0-443-13825-6.00317-4
Rezki, A. (2019) · theses.fr (ABES) · doi:10.70675/392902d9z7810z4025zb9afz3081c32bac5d
Kumar, D., Singh, S. B., Sagar, V., Prasad, M. K., Kapoor, N., Mukul, A., & Nishant, A. (2026) · Indian Journal of Public Health · doi:10.4103/ijph.ijph_102_25
142Chapter 7 4D Printing in Stimuli-Responsive Materials
Malviya, R., Kumar, S., Sridhar, S. B., & Shivappa, P. (2026) · De Gruyter eBooks · doi:10.1515/9783111634609-007
Diabetestechnologie (Update 2026)
Schütz-Fuhrmann, I., Rami-Merhar, B. M., Hofer, S. E., Fröhlich-Reiterer, E. E., Tauschmann, M., Mader, J. K., Resl, M., Kautzky‐Willer, A., Winhofer-Stöckl, Y., Wascher, T. C., et al. (2026) · Wiener klinische Wochenschrift · doi:10.1007/s00508-025-02630-7
Everett, E. M., Shaw, E., Escobar, B., Brumley, B., Lane, K. L., Moin, T., & Wisk, L. E. (2026) · JMIR Diabetes · doi:10.2196/97122
Sánchez-Arlegui, A., Muñoz‐Pardeza, J., Hormazábal‐Aguayo, I., Abio-Abero, S., Bertholt-Zuber, M. L., Alonso-Rubio, P., Sánchez, E. B., Chueca-Guindulain, M. J., Zamalloa, C. C., Congost-Marín, S., et al. (2026) · Frontiers in Endocrinology · doi:10.3389/fendo.2026.1913568
Pongrujikorn, J., Jitchana, J., & Laichuthai, N. (2026) · Journal of the ASEAN Federation of Endocrine Societies · doi:10.15605/jafes.041.02.6355
Валерьевич, П. В., & Noskova, E. D. (2026) · Meditsinskiy sovet = Medical Council · doi:10.21518/ms2026-189
Initiation of Continuous Glucose Monitoring and Insulin Pump Therapy
Hindmarsh, P. C., Gupta, A., Swart, A., & Cooper, A. (2026) · Springer eBooks · doi:10.1007/978-3-032-24854-1_6
Knowledge and Attitudes Regarding Continuous Glucose Monitors as Predictors of Current Use
Gallegos, S. P., Zohn, J. H., Hutchins, A. M., Derksen, L. A., & Benton, M. J. (2026) · The Science of Diabetes Self-Management and Care · doi:10.1177/26350106261483745
A wearable closed-loop insulin micropump toward a miniaturized artificial pancreas for diabetes
Kuang, Z., Kong, X., Cao, T., Lin, R., Long, Z., Jiang, T., Jin, X., Xue, X., Zhao, Z., & Chen, M. (2026) · Microsystems & Nanoengineering · doi:10.1038/s41378-026-01463-2 · Cited by 1
Metadata
- Authors
- Yeh, H.-C., Brown, T. T., Maruthur, N., Ranasinghe, P., Berger, Z., Suh, Y. D., Wilson, L. M., Haberl, E. B., Brick, J., Bass, E. B., & Golden, S. H.
- Affiliations
- Johns Hopkins University (US)
- Harvard University (US)
- ORCID
- Venue
- Annals of Internal Medicine
- Publisher
- American College of Physicians
- Published
- 2012-09-04
- Volume
- 157
- Issue
- 5
- Pages
- 336-347
- ISSN
- 0003-4819 (ISSN-L)
- 1539-3704
- OpenAlex
- W2035018400
- Semantic Scholar
- 6a9836e0bc9a84e7b30be275ad35b904df13faab
- Cited by
- 493
- References
- 72
- Citations by year
- 2026: 14 · 2025: 15 · 2024: 27 · 2023: 19 · 2022: 31 · 2021: 38 · 2020: 45 · 2019: 44 · 2018: 48 · 2017: 36 · 2016: 48 · 2015: 46 · 2014: 48 · 2013: 32 · 2012: 2
- FWCI
- 5.63
- Type
- journal article
- Language
- en
- Open access
- green
- hdl.handle.net
- Licence
- cc-by-nc-nd
- www.acpjournals.org/journal/aim/text-and-data-mining (tdm)
- Locations
- Annals of Internal Medicine (publishedVersion)
- PubMed (publishedVersion)
- Repositorio UTB (submittedVersion, cc-by-nc-nd)
- Funders
- National Institute of Diabetes and Digestive and Kidney Diseases (P30DK079637)
- Topics
- Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Management and Research
- Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Management and Education
- Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Treatment and Management
- Keywords
- diabetes mellitus, insulin delivery, insulin pump therapy, multiple daily insulin injections, sensor-augmented pump, continuous glucose monitoring, self-monitoring of blood glucose, glycemic control, HbA1c, hypoglycemia, type 1 diabetes, type 2 diabetes, intensive insulin therapy, rapid-acting insulin analogs, children and adults, comparative effectiveness
- MeSH terms
- Blood Glucose, Diabetes Mellitus, Type 1, Diabetes Mellitus, Type 2, Glycated Hemoglobin, Humans, Hypoglycemic Agents, Insulin, Insulin Infusion Systems, Monitoring, Physiologic, Blood Glucose Self-Monitoring, Treatment Outcome, Comparative Effectiveness Research
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.